Minimum wlc code for 1600 series ap's?

I have been searching through the cisco docs for a while and i just cant seem to find this info. Can I run aironet 1600's with my wism running 7.0.116? Also, could I run my 1130 series ap's with a wism2? Basically, what is the minimum code level for a lightweight 1600, and what is the maximum code level for a lightweight 1130?

For the 1600 to work you need to be running 7.4 code.  Per the release notes 7.4 will support both AP models you have
http://www.cisco.com/en/US/partner/docs/wireless/controller/release/notes/crn74.html
HTH,
Steve
Please remember to rate useful posts, and mark questions as answered

Similar Messages

  • WLC code for point to point bridging

    What is the best WLC code for point to point and point to multipoint bridging on a 2504 with 2602 APs? 7.2-7.4 had transparent vlan issues and I'm not sure if they were fixed in 7.5-7.6. We have 5-6 vlans that we are needing to bridge between a large open area. Also, are there any bugs with wireless mesh and ISE?

    You do not have many choices now, only 7.0.250.0, 7.4.121.0 & 7.6.110.0 codes are supported by Cisco. All other codes have been deferred by them.
    I do not have configured those set-up to advise you specific to that. I would think 7.6.110.0 may have fixed whatever the known bugs in previous versions.
    HTH
    Rasika
    **** Pls rate all useful responses ****

  • WLC- code for AP

    I have very silly question ...
    Where the wlc stores the image/code for ap..?  how to see the file systems through CLI/GUI ...?
    KVS

    If you issue the show run-config from the WLC cli, you will see what available AP images are associated with that WLC image.
    Sent from Cisco Technical Support iPhone App

  • WLC 5508 - AP 1600 serie's are conecting with WLC but unable to regester with WLC and country is US no matter what I do, i can't change it

    Hello everyone!
    I have a controller of the 5508 series and Ap 1602.
    Ap manage to obtain IP addresses from the DHCP server that is the 5508 controller.
    but the Rev fail to register, please I really vesoin help.
    Below are some show:
    1.  AP:  sh version
    AP0006.f6d5.ea9c#sh version
    Cisco IOS Software, C1600 Software (AP1G2-RCVK9W8-M), Version 15.2(2)JB, RELEASE SOFTWARE (fc1)
    Technical Support: http://www.cisco.com/techsupport
    Copyright (c) 1986-2012 by Cisco Systems, Inc.
    Compiled Tue 11-Dec-12 04:52 by prod_rel_team
    ROM: Bootstrap program is C1600 boot loader
    BOOTLDR: C1600 Boot Loader (AP1G2-BOOT-M) LoaderVersion 15.2(2)JAX, RELEASE SOFTWARE (fc1)
    AP0006.f6d5.ea9c uptime is 38 minutes
    System returned to ROM by power-on
    System image file is "flash:/ap1g2-rcvk9w8-mx/ap1g2-rcvk9w8-mx"
    Last reload reason:
    This product contains cryptographic features and is subject to United
    States and local country laws governing import, export, transfer and
    use. Delivery of Cisco cryptographic products does not imply
    third-party authority to import, export, distribute or use encryption.
    Importers, exporters, distributors and users are responsible for
    compliance with U.S. and local country laws. By using this product you
    agree to comply with applicable laws and regulations. If you are unable
    to comply with U.S. and local laws, return this product immediately.
    A summary of U.S. laws governing Cisco cryptographic products may be found at:
    http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
    If you require further assistance please contact us by sending email to
    [email protected].
    cisco AIR-CAP1602E-E-K9    (PowerPC) processor (revision A0) with 98294K/32768K bytes of memory.
    Processor board ID FGL1709Z6PC
    PowerPC CPU at 533Mhz, revision number 0x2151
    Last reset from power-on
    LWAPP image version 7.4.1.37
    1 Gigabit Ethernet interface
    32K bytes of flash-simulated non-volatile configuration memory.
    Base ethernet MAC Address: 00:06:F6:D5:EA:9C
    Part Number                          : 73-14508-04
    PCA Assembly Number                  : 000-00000-00
    PCA Revision Number                  :
    PCB Serial Number                    : FOC17020MTR
    Top Assembly Part Number             : 800-38553-01
    Top Assembly Serial Number           : FGL1709Z6PC
    Top Revision Number                  : A0
    Product/Model Number                 : AIR-CAP1602E-E-K9
    Configuration register is 0xF
    2.  AP:  sh ip interface brief
    Interface                  IP-Address      OK? Method Status                Protocol
    BVI1                       unassigned      YES DHCP   up                    up
    GigabitEthernet0           unassigned      NO  unset  up                    up
    GigabitEthernet0.1         unassigned      YES unset  up                    up
    3.  AP:  sh inventory
    ---nothing---
    4.  WLC:  sh sysinfo
    (Cisco Controller) >show sysinfo
    Manufacturer's Name.............................. Cisco Systems Inc.
    Product Name..................................... Cisco Controller
    Product Version.................................. 7.3.101.0
    Bootloader Version............................... 1.0.1
    Field Recovery Image Version..................... 6.0.182.0
    Firmware Version................................. FPGA 1.3, Env 1.6, USB console 1.27
    Build Type....................................... DATA + WPS
    System Name...................................... WLC-EEML
    System Location..................................
    System Contact...................................
    System ObjectID.................................. 1.3.6.1.4.1.9.1.1069
    Redundancy Mode.................................. Disabled
    IP Address....................................... 10.10.10.1
    Last Reset....................................... Software reset
    System Up Time................................... 1 days 1 hrs 13 mins 37 secs
    System Timezone Location.........................
    Configured Country............................... US  - United States
    Operating Environment............................ Commercial (0 to 40 C)
    Internal Temp Alarm Limits....................... 0 to 65 C
    Internal Temperature............................. +39 C
    --More-- or (q)uit
    External Temperature............................. +25 C
    Fan Status....................................... OK
    State of 802.11b Network......................... Enabled
    State of 802.11a Network......................... Enabled
    Number of WLANs.................................. 1
    Number of Active Clients......................... 0
    Burned-in MAC Address............................ E0:2F:6D:5D:7D:C0
    Power Supply 1................................... Present, OK
    Power Supply 2................................... Absent
    Maximum number of APs supported.................. 25
    5.  WLC:  sh time
    Time............................................. Fri Jan  3 12:21:37 2014
    Timezone delta................................... 0:0
    Timezone location................................
    NTP Servers
        NTP Polling Interval.........................     86400
         Index     NTP Key Index     NTP Server      NTP Msg Auth Status
    also, I'm in africa but
    I can not change the country or the time zone
    thank you in advance for your help

    Hi,
    By CLI:
    Before change the country code on wlc , You must disable
    WLC > config 802.11a disable network
    WLC  >config 802.11b disable network
    WLC  >config country SA (...or wtever country u are in)
    And then enable both network again.
    WLC  >config 802.11a enable network
    WLC  >config 802.11b enable network
    By GUI:
    First disable both network 802.11a and 802.11b
    Follow these steps to disable the 802.11a and 802.11b/g networks as follows:
    a.          Choose Wireless> 802.11a/n > Network.
    b.          Unselect the 802.11a Network Status check box.
    c.          Click Apply to commit your changes.
    d.          Choose Wireless > 802.11b/g/n > Network.
    e.          Unselect the 802.11b/g Network Status check box.
    f.          Click Apply to commit your changes.
    Change country code on WLC now:
    Choose Wireless > Country
    after changing the country code please enable both networks(802.11a and 802.11b)
    Hope it helps.
    Regards
    Dont forget to rate helpful posts.

  • I can no longer use the driver for my PSC 1600 Series as of two days ago.  The message tells me that the software is not available to update! Has anyone else encountered this.  I have OS 10.73 and a MacBookPro

    As of two days ago, the ability to print from my MacBookPro to the PSC 1600 Series vanished, indicating they do not have new software ready.  I have tried HP and Apple but have not received any help.  Can anyone help me to find whatever software that was either lost or not updated.  My iMac did have an HP update.

    Latest drivers for HP:
    http://support.apple.com/kb/DL907?viewlocale=en_US&locale=en_US

  • What are the following:1)Cisco 1600 Series IOS WIRELESS LAN RECOVERY. 2)Service Provider Option 60 for Vendor Class Idenfier

    What are the following:1)Cisco 1600 Series IOS WIRELESS LAN RECOVERY. 2)Service Provider Option 60 for Vendor Class Idenfier
    These items are listed with 1600 series AP but I'm unable to understand what are these things & the use of them

    DHCP Option 60:  Go HERE.

  • M Series code for Labview

    I am using the PXI-6230 on Linux.  I downloaded the MHDDK for NI-Visa, and the code uses C, along with some examples that are in C.  There are some good examples, but I need working code that will work in Labview.  Are there some examples that people have for the PXI-6230?  Or is there some way I can use the C code for Labview?  Any help is appreciated.
    Thanks,
    Thomas Pham

    Hi Thomas,
    The DDK is a set of reference examples for writing a device driver from scratch. Since most write-it-yourselfers expect to be running in an uncommon environment (where LabVIEW cannot run) or need to undergo some kind of final validation or peer review (where not everyone may have LabVIEW available), a text-based implementation provides them a faster "see how it works" starting point for those purposes.
    When programming for the 6230 from LabVIEW, you have a few options available.
    You can use the existing C++ chip objects in the DDK but manipulate them into a shared library (a .so) so that you can call the Library Function Node in LabVIEW [1].
    You can use the register I/O palette [2] in VISA and transcribe the C++ chip objects into LabVIEW.
    Expand the DAQmx Base driver [3] to make the extra RLP calls for the 623x (explained below).
    All three are somewhat challenging, and you will also need some additional information about the specifics of programming for the 623x sub-family. Since they have isolated IO, some of the registers are re-purposed for enabling and disabling the isolators. There are several threads in this forum [4] about the 623x-specific calls that need to be made.
    If you choose to exapand the DAQmx Base driver, you will find that a bug in the code will make the system think your 6230 is a 6222 [5]. In addition the 623x-specific RLP calls, you'll need to correct and differentiate the 6230 from the other M Series boards.
    [1] Call Library Function Node -- LabVIEW Help
    http://zone.ni.com/reference/en-XX/help/371361G-01​/glang/call_library_function/
    [2] Register Access Functions -- VISA Help
    http://zone.ni.com/reference/en-XX/help/371361G-01​/lvinstio/high_level_reg_acc_func/
    [3] DAQmx Base 3.4 for Linux
    http://joule.ni.com/nidu/cds/view/p/id/2128/lang/e​n
    [4] 623x RLP Considerations
    http://forums.ni.com/t5/forums/searchpage/tab/mess​age?location=Node%3A90&q=623x#message-list
    [5] DAQmx Base 3.4 incorrectly attaches to the 6230
    http://decibel.ni.com/content/message/20827#20827
    Joe Friedchicken
    NI VirtualBench Application Software
    Get with your fellow hardware users :: [ NI's VirtualBench User Group ]
    Get with your fellow OS users :: [ NI's Linux User Group ] [ NI's OS X User Group ]
    Get with your fellow developers :: [ NI's DAQmx Base User Group ] [ NI's DDK User Group ]
    Senior Software Engineer :: Multifunction Instruments Applications Group
    Software Engineer :: Measurements RLP Group (until Mar 2014)
    Applications Engineer :: High Speed Product Group (until Sep 2008)

  • Intermec 751 Handhelds and WLC code versions

    We have Intermec 751 mobile handhelds and three WLAN controllers. A 4404-100, 4402-25, and a 2000-6. The 4404 & 2000 series are running 3.x WLC code and the 4402-25 is running 4.x.
    We're using the same SSID & WPA-PSK on all three controllers, and the handheld associates with the controllers that have the 3.x code, but not the WLC with 4.x code. Besides the different code, we have the exact same WLAN's defined. We've also tried creating an Open WLAN with no security, and still nothing. We're using the Intermec Settings app to manage the WLAN settings..
    Has anyone run into this before? Other devices - laptops and CK30 scanners can connect, but not the 751's. We're going to open up a TAC as well, but I thought I'd check the boards to see if anyone else has encountered anything similar.

    I found this on Intermec's "Knowledge Central". I don't know if this will help but it's worth a shot. It's seems "SR06236001" fixes Cisco LWAPP version 4.x compatibility. Here is the full KC post.
    Scope:
    7x1 terminals running OSv4.95.1 PSMv4.03 with SR06236001 installed using Funk-WPA-TLS-LWAPP v4.x
    Problem Description/Purpose:
    The terminal will reauthenticate on the network approximately once every twelve minutes. If hundreds of terminals are deployed, this creates a large amount of unwanted reauthentication traffic on the authentication server.
    Answer
    Solution/Action Plan:
    Intermec Engineering recommends enabling CCKM to reduce frequent and unwanted reauthentication messages on the authentication server.
    SR06236001 also offers these enhancements to OS version 4.95.1/4.03 PSM on the 751A, 761A and CN2BA with WM2003:
    1. Power managed radio response time is improved (PSP).
    2. Roaming performance with LEAP is improved.
    3. Fix for Cisco LWAPP version 4.x compatibility.
    4. Fixes a CCX association ID problem that was associated with CCKM.
    Do not use SR06236001 on devices other than the 751A, 761A, or CN2BA (Samsung radio).
    SR06236002 is specifically for the CN30A with Windows Mobile 5 and contains the same enhancements (Samsung radio). This updated has been tested on CN30 OS version 2.47 with version 2.01 SD Card Image.
    Installation instructions for either SR listed above:
    1. copy the associated CAB file to \CabFiles and warm boot
    or
    2. copy the CAB file to \Temp folderand double-click on it.
    The terminal will automatically warm boot after the SR is installed.

  • AVC support for 3500 Series AP on 5760 platform

    Hi all,
    The title says it all. According to the 5760 Configuring Application Visibility and Control guide only the following AP types are supported
    Cisco Aironet 1600 Series Access Points
    Cisco Aironet 2600 Series Wireless Access Points
    Cisco Aironet 3600 Series Access Points
    What about the 3500 Series? Is it not (yet) supported? They are still relatively new and AVC works on AireOS based WLCs.
    Had not yet the chance to do a test myself, so I am asking here.
    Regards,
    Patrick

    Hi Patrick,
    Here is the latest AVC guide for 5760. Only addition was 3700 to the list of 1600,2600 & 3600.
    http://www.cisco.com/en/US/customer/docs/wireless/controller/technotes/5700/software/release/ios_xe_33/iosXE_3point3_AVC_DG.html
    So no support for 3500.
    I do not think Cisco will make it work as they want to discontinue 3500 series.
    HTH
    Rasika
    **** Pls rate all useful responses ****

  • WLC code upgrade, WCS, ap_3600

    i'm going to upgrade a 5508 wlc code from
    7.0.116.0
    to
    7.1.91.0
    to add 3600 series access points having it all manageable via WCS ver 7.0.230.0
    it seems to be possible, as it is explained in the compatibility matrix found on
    http://www.cisco.com/en/US/docs/wireless/controller/5500/tech_notes/Wireless_Software_Compatibility_Matrix.html
    now I have to download the file to the controller...
    AIR-CT5500-K9-SPECIAL-7-1-91-0.aes
    (direct update possible)
    before doing that I'd like to know if I will loose my configuration on the controller
    i'm concerned about that because the release document is not clear:
    - We highly recommend that you back up your controller's configuration files prior to upgrading the controller software. Otherwise, you must manually reconfigure the controller.
    - For busy networks, controllers on high utilization, or small controller platforms it is advisable to disable the 802.11a/b/g networks as a precautionary measure.
    - Step 5 Disable any WLANs on the controller.
    - Step 19 Re-enable the WLANs......
    - Step 22 If desired, reload your latest configuration file to the controller. (reload config after reenabling wlans????? why???)
    so will I loose my configuration?
    what is Field Upgrade Software? should i use that instead?
    another controller  another question .....: a cisco wlc 2100
    found 2 update files
    AIR-WLC2100-K9-7-0-230-0-ER.aes
    AIR-WLC2100-K9-7-0-230-0.aes
    why 2 update files this time? what file to update first?
    thank you in advance for your answers

    The 5508 has two files when you go to 7.2, which I would for the 3600.  You'll also want to download and install the FUS image.
    the 'legacy' WLC, like the 2100, have the .aes which is the OS for the WLC.  The -ER is an Emergency Recovery image, it's waht you get when you break the boot cycle.
    HTH,
    Steve
    Please remember to rate useful posts, and mark questions as answered

  • Minimum order value for Purchase orders

    Hello,
    This is my requirement: -
    A condition type needs to be created for Minimum Oder Value for PO. If the PO value is say, 450 and the condition record in 500, the PO value must be adjusted to 500. If PO value is 550, then it remains 550.
       1. Condition records must be maintained.
       2. Must be calculated on whole PO (all items) and then redistributed among items in a suitable ratio.
    This is what I have already tried:-
      1. Vendor master - No use maintain minimum order value as PO price must be adjusted through condition types.
      2. Tried replicating PMIN condition type and it works but only at item level - this calculation must take place at header level. Also it works only for calculation type "Quantity".
    Please suggest how this can be implemented, hopefully through configuration only.

    Hi,
    Please use user exit MM06E005 and code accordingly. Take help of ABAPer.
    thanks and regards
    Murugesan

  • HT5047 I've just downloaded ver 7 operating software AND ENTERED A SECURE CODE FOR THE PHONE NOW I CAN"T USE IT TO OPEN  A MESSAGE FROM FACE BOOK

    I just downloaded 0s 7 ser a code for security and when i recieved a nessage from facebook and was asked to enter the code it would:nt work and finally locked my phone. Help!!

    Reinstall Safari 5.1.1
    If that doesn't help install the Mac OS X 10.6.8 Update Combo. It's ok to do this even though you are already running v10.6.8.
    Restart your Mac after installing software.

  • How to disable a custom designed Tx code for multiple user at a time

    Hii ,
    I have designed a screen in module pool for end user to make entries in the screen and when he saves the data is saving in standard table and ztable. the main field in the screen is Batch number..from that batch  number bag number will be generated. and consumed quantity will be saved in that bag no.Bag number will be generated like first 5 digits of batch number and bag number series of that batch number. for example if batch number is 12345 and already 5 times packing is done for same batch..last bag number in the ztable will be 123450005.so next time when user tries to pack using same batch number the new bag number will be 123450006 for batch 12345.Problem here is when user tries to make enrties in that Tx code and at the same time if another user opens same Tx code to make packing for same batch both of them are getting same bag numbers before saving.
    I have called Enqueue and Dequeue FM's but still at a time for same batch user is able to do the packing.now my issue is i want to restrict 2 user to use same batch while packing in that Tx code.
    I have written following code for enqueue and dequeue technics
    data: B_matnr type mara-matnr,
           B_charg type mchb-charg.
    data : i_temp type TABLE OF zpackhdr WITH HEADER LINE,
           i_temp1 type TABLE OF zpackhdr WITH HEADER LINE.
    move : 1110 to WA_BCH-werks,
           chk_matnr1 to WA_BCH-matnr,
           v_bcharg to WA_BCH-charg,
           vgrade to WA_BCH-grade,
           new_batch to WA_BCH-bagno,
           m_baleno to WA_BCH-baleno,
           b_date to WA_BCH-indat.
    APPEND wa_bch to i_bch.
    clear b_date.
    READ TABLE i_bch INTO wa_bch INDEX 1.
        B_MATNR = WA_BCH-matnr.
        B_CHARG = WA_BCH-bagno.
    concatenate  B_matnr B_charg  into
        WA_BCH-objek respecting blanks .
       modify I_BCH from WA_BCH index sy-tabix.
    CLEAR: B_MATNR,
               B_CHARG.
    call function 'ENQUEUE_EMMCH1E'
    EXPORTING
       MODE_MCH1            = 'E'
       MANDT                = SY-MANDT
       MATNR                = WA_BCH-MATNR
       CHARG                = WA_BCH-BAGNO
    if sy-subrc <> 0.
    endif.
    call function 'DEQUEUE_EMMCH1E'
    EXPORTING
       MODE_MCH1       = 'E'
       MANDT           = SY-MANDT
       MATNR           = WA_BCH-MATNR
       CHARG           = WA_BCH-CHARG

    I do understand what u say...mine is a custom designed screen...when i open that screen i have around 15 input fields in which batch is obligatroy...when i give batch and hit enter all the other fields will be filled automatically picking from the table which are relevant for that batch..for example..material,order etc are picked from table...and bag number field will be generated taking first 5 digits of batch and followed by 0001 if its afirst time entry for that batch....so when a user is opening that screen in 2 different windows and giving details without saving any of the screens...in both screens bag number is generating as 001...and when saving it ..its saving 2 entries with same bag number...so i have created a lock entry for afpo table taking order field...so when a user opens 2 screens with same batch...and giving entries in those 2 screens without saving..he is getting same bag numbers as 001.....now when user saving the first screen and coming to second screen to save...he is gettimg message 'ORDER CURRENTLY BEING PROCESSED'..but after the data gettng saved in first screen,then when he saves the second screen it is getting saved...with same bag numbers as 001.so my issue is here...when he saves first screen and comes to second screen to save it the user should get that error message and should come out of the screen....so that he can make a fresh entry for that batch and bag number will be generated as 002 for that batch...
    Regards,
    venkat.

  • Code for NSImageView

    Using Project Builder, I have made an appleScript application that selects photos with a browser then tells Photoshop to make a series of changes to them using actions. I would like to have an NSImageView as part of the interface window but it seems to need code for many handlers. Is there a sample of workable code for these handlers anywhere? Thanks...

    Hi HerbA
    Some of this code may be of use to you, it's plucked straight out of one of my projects that im working on, it works fine for me in my project. (im open to improvement suggestions also).
    global the_image
    on clicked theObject
    --CLOSES THE VIEWER PANEL--
    if name of theObject is "cancel" then
    delete image of image view "image" of window "VIEWER"
    delete contents of text field "pathto" of (window "VIEWER")
    close panel (window "VIEWER")
    end if
    --OPENS THE VIEWER PANEL--
    if name of theObject is "getviewer" then
    display (window "VIEWER") attached to window "MAIN"
    end if
    --DELET IMAGE FROM IMAGE VIEWER --
    if name of theObject is "delete" then
    delete image of image view "image" of window "VIEWER"
    delete contents of text field "pathto" of (window "VIEWER")
    end if
    --RUNS THE BARBER POLE or spinning ICON--
    tell window "VIEWER"
    set indeterminate of progress indicator "bar_Progress" to true
    set uses threaded animation of progress indicator "bar_Progress" to true
    set animation delay of progress indicator "bar_Progress" to 1
    tell progress indicator "bar_Progress" to start
    end tell
    --GETS THE IMAGE AND OPENS THE IMAGE IN ITS APPLICATION--
    tell window of theObject
    if name of theObject is "userpick" then tell me to get_picture()
    if name of theObject is "openfile" then tell me to open_picture()
    end tell
    end clicked
    on get_picture()
    set the_image to (choose file without invisibles)
    set new_image to load image the_image
    set image of image view "image" of window "VIEWER" to new_image
    set text color of text field "pathto" of window "VIEWER" to {0, 0, 65535}
    set contents of text field "pathto" of window "VIEWER" to the_image as string
    end get_picture
    on open_picture()
    if content of text field "pathto" of window "VIEWER" is not "" then
    tell application "Finder" to open the_image
    else
    display dialog "Please use - Select item to view - first." with icon caution
    end if
    end open_picture
    tell progress indicator "bar_Progress" to stop
    end clicked
    hope this helps
    Budgie

  • Called-Station-ID attribute and Cisco WLC code 7.4

    Hello
    I have 2 WLCs configured with 2 SSIDs (one is [WPA2][Auth(802.1X)] and the other is Web-Auth). One of the WLCs is remote and its WLANs are configured with mobility anchors pointing to the other WLC. Both WLCs are configured with Called-Station-ID set to AP Mac Address:SSID. I use this attribute on ACS to authenticate/authorize users based on what SSID they connect to.
    This worked fine on WLC code 7.0 but on upgrading to 7.4 I started having some issues:
    clients on the remote WLC can still authenticate on the [WPA2][Auth(802.1X)] SSID as the Called-Station-ID attribute is still AP Mac Address:SSID
    clients on the remote WLC cannot authenticate on the Web-Auth SSID as the Called-Station-ID attribute now appears to be the Mac Address of the WLC anchor controller
    WLC models are 5508 and current code is 7.4.110.0 (APs are AIR-LAP1142N-E-K9). Can anyone tell me why I'm seeing this behaviour on the Web-Auth SSID on the remote WLC?
    Thanks
    Andy

    Since you have two AAA devices that's sending info, you can have your policy for the guest specifying the guest WLC. The SSID policy for the foreign WLC is only really needed if you have multiple 802.1x authentication from the foreign WLC and that's when you can use the regex to defiance the SSID per AD Group.
    Look at a successful authentication from one of the guest users. Look at the detailed log and then in that log, you will see all the attributes being sent that the radius can send back to the WLC. You can use any of those attributes in your policies.
    Called-Station-ID might not be sent like what your use to, because the foreign WLC has the access point the guest user associates to and tunnels it back to the anchor WLC. So this attribute might not be available. Things do change with code versions so you might just have to adjust your policies. I haven't played around with 7.0.x code with guest anchor and radius in a while, but I have in the past upgraded radius or the WLC and had to tweak my radius policies.
    Sent from Cisco Technical Support iPhone App

Maybe you are looking for