MIRO : Internal error in program SAPLEINR in position L014 (RC = 4)

Hi Gurus,
I have got a problem with MIRO.
When i provide 'test' in Reference field and PO number in PO Reference tab i am getting error message saying
"Internal error in program SAPLEINR in position L014 (RC = 4)".
What could be the reason for this error message and solution if any?
Thanks in Advance!
Pavan.

Hi Pavan,
I take it the error message number is C+509?
This error is usually caused by inconsistencies between table EKPO and KONV. Check out note 205723 and implement the
report ZKORKONV, you might want to run it in test mode first with the flag db_upd unchecked.
Hope this helps,
Adam.

Similar Messages

  • Error while executing  tcode FSE2 "Internal error in program SAPLFIBS no 5"

    I am getting below error which while trying to execute tcode FSE2 (Financial statement version). Can't able even go inside the tcode.  Please tell how to solve this.
    "Internal error in program SAPLFIBS number 5"

    Hi Dsr,
    Use transaction code <b>OB58</b>->Highlight the Fin. Stmt. version you want to Change and click on the <b>Display</b> icon.->Next, click on the "<b>Fin.Statement items</b>" icon on the application tool bar. You can then expand and carry out your update as appropriate.
    If you do not have the prerequisite authorisations, you wouldn't be able to do this.
    I hope the above helps.
    Do not forget to award the points please.
    Regards,
    Jacob

  • Internal error in program SAPLRSDRS and method WRITE_DDIC_INFO-6-?

    Hi All,
    When i load data from self system to the targets i got an error message "Internal error in program SAPLRSDRS and method WRITE_DDIC_INFO-6-"...
    could any body help me to resolve this type of issues.
    Thanks in advance.
    Thanks,
    Vachan

    No this is not a short dump message...these error message i am seeing the error message in the monitor...in the detail tab extraction 'Error occurred in the data selection " and  then there is no trfcs and idocs processing and even processing also not happened.
    thanks ,
    Vachan

  • Internal error in program CL_RSDD_VCUBE and method GET_SID-8-)

    Hi
    I am getting the (Internal error in program CL_RSDD_VCUBE and method GET_SID-8-) this error while running the query on remote cube.
    Source system is oracle.
    We are trying to access the data in reports from oracle by using UD COnnect.
    When i ran the report on the remote cube i am getting the above error
    we are using bw 3.5 system patch level 15
    Please help me out .
    Thanks
    Sirisha

    Check OSS note  702068.
    also see this thread..
    Re: Query Error (CL_RSDD_VCUBE ...)

  • Error positng Invoice using MIRO  - Internal Error  read error SMBEW, Key =

    Hello Friends ,
    User is facing a strange issue while posting a Invoice using MIRO .
    The error says " Internal Error ( Read Error SMBEW, Key = 000000000001011376120000000000 )
    Message no . M8782
    Procedure
    Contact your system administrator
    please provide your valuable inputs .
    thanks,
    Raghu V

    Its a programme error...you have to check & implement SAP note 326826...otherwise contact SAP directly
    Regards,
    Indranil

  • ThinInstaller - all Updates fail with Errors internal error -532459699 / eGatherer: -1066598274

    Hi There
    i try to use Thininstaller with SCCM Tasksequence and Windows XP Sp3 on a X201 model
    i use this method already with Windows 7 and Windows Xp with different Models and it works pretty nicely.
    in the above combination i do not get anything installed. in the log file i see that
    a few updated get selected
    Info 2010-12-17 , 04:36:19
     at Tvsu.Coreq.LoadCoreqsProcessor.ProcessUpdatesImplementation(Update[] ups)
     Message: Resulted order of candidate list:
    Conexant Audio Software for Windows 7, Vista, and XP[reboot type 3]
    Intel Wireless WiFi Link for Windows XP[reboot type 3]
    Intel Rapid Storage AHCI Driver for Windows 32bit[reboot type 3]
    ThinkPad Bluetooth with Enhanced Data Rate Software II for Windows XP[reboot type 3]
    Thinkpad Integrated Camera Device Driver[reboot type 3]
    STMicro TPM Driver for WinXP 32bit[reboot type 3]
    Intel AMT 6.0 - MEI and SOL driver[reboot type 3]
    Intel Chipset Support for Windows XP/Vista/7[reboot type 3]
    Intel HD Graphics Driver for Windows XP (GM55)[reboot type 3]
    ThinkPad Modem Adapter[reboot type 3]
    ThinkPad UltraNav Driver for Windows 32-bit[reboot type 3]
    ThinkPad Power Management Driver[reboot type 3]
    ThinkPad Hotkey Features Integration Package Setup[reboot type 3]
    ThinkVantage Access Connections for Windows XP[reboot type 3]
    ThinkPad Power Manager[reboot type 3]
    ThinkPad UltraNav Utility[reboot type null]
    ThinkPad Wireless WAN (UNDP) Driver[reboot type 3]
    ThinkVantage GPS Version 2.60[reboot type 3]
    but for every piece of software or update i get :
    Info 2010-12-17 , 04:37:11
     at Tvsu.Engine.Process.PackageInstallerProcess.CheckDependencies(Update update)
     Message: Update 6imb05ww is NOT applicable. Error->internal error -532459699, program abort()
    and :
    Info 2010-12-17 , 04:37:14
     at Tvsu.Engine.Process.PackageInstallerProcess.CheckDependencies(Update update)
     Message: Update 85cx28ww is NOT applicable. Error->internal error -1066598274, program abort()
    Severe 2010-12-17 , 04:37:14
     at Tvsu.Engine.Process.PackageInstallerProcess.InstallNewUpdates()
     Message: Update 85cx28ww is not applicable
    Info 2010-12-17 , 04:37:14
     at Tvsu.GenericPackageInstaller.GenericPackageInstaller..ctor(Update update)
     Message: Update Local Directory: C:\WINDOWS\TEMP\\ThinInstaller\81u716ww\
    does anyone have a hint how to fix this?
    thanks in advance

    Hello Herik,
    thanks Herik, your hint regarding the triplet was indeed justified. i recognized that the OS was basically english with an applied language pack and i just had the added language in the repository. that may have cause the 'ist not applicable' error. even though the updates were downloaded and could be installed by manual starting them.
    After i fixed the error with the triplet and added the basic language it worked a little better, hence installing like 6 out of 20 updates.
    the os is pretty simple
    WinXP with SP3 english with german language pack
    .Net Framework 3.5 SP1
    nothing else
    today i rebuild my repository from scratch after recognizing that almost all files were updated lately on the lenovo website regarding this model.
    but unfortunately it still does not work reliably with windows XP -> on Windows 7 it no problem at all.
    it looks like it detects all the suitable updates but does not extract them correctly to be used by the setup command issued later. it looks like this:
    Info 2011-01-07 , 10:33:31
     at Tvsu.Executor.CommandLauncher.ExecuteCommandLine(String dir, String cmd, String args, String _installType, Int64 timeOut, Boolean hide)
     Message: The parameters directory and command stay as follows:
    Command: C:\WINDOWS\TEMP\THININ~1\6na127ww\Setup.exe -s
    Directory: C:\WINDOWS\TEMP\\ThinInstaller\6na127ww\
    Info 2011-01-07 , 10:33:31
     at Tvsu.Executor.CommandLauncher.ExecuteCommandLine(String dir, String cmd, String args, String _installType, Int64 timeOut, Boolean hide)
     Message: hide window: False
    Info 2011-01-07 , 10:33:31
     at Tvsu.Executor.CommandLauncher.ExecuteCommandLine(String dir, String cmd, String args, String _installType, Int64 timeOut, Boolean hide)
     Message: Type normal
    Severe 2011-01-07 , 10:33:31
     at Tvsu.Executor.CommandLauncher.ExecuteCommandLine(String dir, String cmd, String args, String _installType, Int64 timeOut, Boolean hide)
     Message: Error executing command: C:\WINDOWS\TEMP\THININ~1\6na127ww\Setup.exe -s
     Exception:
      Message: The system cannot find the file specified
      Type: System.ComponentModel.Win32Exception
         at System.Diagnostics.Process.StartWithCreateProcess(ProcessStartInfo startInfo)
       at System.Diagnostics.Process.Start()
       at Tvsu.Executor.CommandLauncher.ExecuteCommandLine(String dir, String cmd, String args, String _installType, Int64 timeOut, Boolean hide)
    on verifiying the exsistance of the setup in question i find that for example the 6na127ww.exe is there but could not be extracted.
    if i run the setup in question manually it works like a charm.
    if you need any other information i am happy to supply them.
    the scan detects all those updates:
    Info 2011-01-07 , 10:26:53
     at Tvsu.Coreq.LoadCoreqsProcessor.ProcessUpdatesImplementation(Update[] ups)
     Message: Resulted order of candidate list:
    Intel Rapid Storage AHCI Driver for Windows 32bit[reboot type 3]
    ThinkPad Modem Adapter[reboot type 3]
    Help Center[reboot type 3]
    Intel Wireless WiFi Link for Windows XP[reboot type 3]
    ThinkVantage Productivity Center for ThinkPad[reboot type 3]
    Thinkpad Integrated Camera Device Driver[reboot type 3]
    ThinkVantage Active Protection System (32bit)[reboot type 3]
    Lenovo ThinkVantage Toolbox (32-bit)[reboot type 0]
    Message Center[reboot type 0]
    Intel Chipset Support for Windows XP/Vista/7[reboot type 3]
    Intel AMT 6.0 - MEI and SOL driver[reboot type 3]
    Conexant Audio Software for Windows 7, Vista, and XP[reboot type 3]
    Intel HD Graphics Driver for Windows XP (GM55)[reboot type 3]
    ThinkPad Bluetooth with Enhanced Data Rate Software II for Windows XP[reboot type 3]
    STMicro TPM Driver for WinXP 32bit[reboot type 3]
    ThinkVantage Fingerprint Software 5.8.5[reboot type 3]
    ThinkPad UltraNav Driver for Windows 32-bit[reboot type 3]
    ThinkPad Power Management Driver[reboot type 3]
    ThinkPad Hotkey Features Integration Package Setup[reboot type 3]
    ThinkPad EasyEject Utility[reboot type 3]
    ThinkPad Power Manager[reboot type 3]
    ThinkVantage Communications Utility[reboot type 3]
    ThinkVantage Access Connections for Windows XP[reboot type 3]
    ThinkPad UltraNav Utility[reboot type null]
    ThinkPad Wireless WAN (UNDP) Driver[reboot type 3]
    ThinkVantage GPS Version 2.60[reboot type 3]
    and these ones work:
            Message: Intel Rapid Storage AHCI Driver for Windows 32bitupdate with hardware ID PCI\VEN_8086&DEV_3B2F&CC_010601 was installed successfully
            Message: Update Intel Rapid Storage AHCI Driver for Windows 32bit was installed successfully
            Message: Update ThinkPad Modem Adapter was installed successfully
            Message: Update Help Center was installed successfully
            Message: Update Intel Wireless WiFi Link for Windows XP was installed successfully
            Message: Update Thinkpad Integrated Camera Device Driver was installed successfully
            Message: Update ThinkVantage Active Protection System (32bit) was installed successfully
            Message: Update Lenovo ThinkVantage Toolbox (32-bit) was installed successfully
            Message: Update Message Center was installed successfully
            Message: Update Intel Chipset Support for Windows XP/Vista/7 was installed successfully
            Message: Update Intel AMT 6.0 - MEI and SOL driver was installed successfully
    and these failed:
            Message: Update ThinkVantage Productivity Center for ThinkPad installation failed
            Message: Update Conexant Audio Software for Windows 7, Vista, and XP installation failed
            Message: Update Intel HD Graphics Driver for Windows XP (GM55) installation failed
            Message: Update ThinkPad Bluetooth with Enhanced Data Rate Software II for Windows XP installation failed
            Message: Update STMicro TPM Driver for WinXP 32bit installation failed
            Message: Update ThinkVantage Fingerprint Software 5.8.5 installation failed
            Message: Update ThinkPad UltraNav Driver for Windows 32-bit installation failed
            Message: Update ThinkPad Power Management Driver installation failed
            Message: Because coreq update installation failed, Update ThinkPad EasyEject Utility installation failed
            Message: Because coreq update installation failed, Update ThinkPad Power Manager installation failed
            Message: Because coreq update installation failed, Update ThinkVantage Communications Utility installation failed
            Message: Because coreq update installation failed, Update ThinkVantage Access Connections for Windows XP installation failed
            Message: Because coreq update installation failed, Update ThinkPad Hotkey Features Integration Package Setup installation faile
            Message: Because coreq update installation failed, Update ThinkPad UltraNav Utility installation failed
            Message: Update ThinkPad Wireless WAN (UNDP) Driver installation failed
            Message: Because coreq update installation failed, Update ThinkVantage GPS Version 2.60 installation failed
    thanks

  • Internal error in FORM/FUNCTION get_prkexx(saplckmo) in position 10 with RC

    Hi,
    When we try to post good movements in MFBF, the system gives the error message C+099 which says "Internal error in FORM/FUNCTION get_prkexx(saplckmo) in position 10 with RC".
    We have been implemented the sap notes which are shown below:
    0001096890
    0001126497
    0001164684
    0001230454
    However, it doesn't solve our problem.
    Can you please help us to solve this problem?
    Thanks&Regards,
    Begü

    Dear,
    Just debug the program and check it.
    Also pls check these NOTES,
    414204, 933809, 390655
    Regards,
    R.Brahmankar

  • Internal error in FORM/FUNCTION CKMC_REVALUATE_ENDING_STOCK in position 1 with RC

    Hello SAP Gurus,
    I am getting this error while trying to close a material in Material Ledger Cockpit
    Internal error in FORM/FUNCTION CKMC_REVALUATE_ENDING_STOCK in position 1 with RC
    Message no. C+099
    Procedure
    Please inform your system administrator.
    CKMC reports no inconsistency.
    Does anyone have any suggestion?
    Cheers,
    TD

    Shipa,
    Thanks for your suggestions.  Thanks for taking the time to help.
    I was able to resolve these issues using the following steps in our sandbox/test environments.  I have also included other problems I faced in material ledger month end closing steps for the benefit of readers.
    **** Caution:  Do not do the following steps in production environment.  You will destroy your production data irretrievably.  Material Ledger is unforgiving!!! ***
    1.  For the materials with "Internal Error in Form/Function etc issue, I performed a CKMM in the respective plants changing for 3S to 2S and then did the same in reverse (2S to 3S).  Then ran the ML close.  This seems to have temporarily solved the problem.
    2.  I was also getting a short dump -- either during MMPV or during period close in the cockpit.  The message at both times was "Error in MLCCS ...".  I realized it related to Cost Component Split.  I identified the company codes of the materials that caused the errors, then got all the plants within each of these company codes.  I ran MLCCS_RESET and then MLCCS_Startup in SE38.  Then ran MMPV/ML Close.  This seems to have resolved the issues at least temporarily.
    3.  Occasionally I noticed some "material valuation is inconsistent in valuation area xxxx" error.  I executed steps 1 and 2 above in succession.  This seems to have resolved the issue temporarily.
    4.  There was also the issue of "duplicate entry in CKMLKEV" while performing Single/Multi-Level steps in the closing cockpit.  This pointed to MLCCS.  So I ran step 2 above.  Again this seems to have fixed the issue temporarily.
    I was able to accomplish all of these using the steps above because these were in our test environments.  The reasons as to why these happened are manifold:
    MMPV was not carried out for a long, long, long time in certain plants within a company code.  When ML is active, it is necessary to close previous period.  In cases where MMPV was not carried out for a long time, I ran CKMHELP program to set the material status to 70 for the immediately preceding posting period.  This helped run the ML cockpit for the current/previous periods.
    Users were processing too many transactions with unrealistically large quantities and prices resulting in overflow errors.  I carried out reversal of movements for each process category to reduce the inventory balances to reasonable quantities, and ran MR21 to set the prices correctly.  This helped resolve the overflow issue.
    Reckless, repeated running of CKMM and MLCCS_Reset/MLCCS_Startup also contributed to these problems.  Every time a standard had to be released, but the material status in ML is "30-Quantities and Values entered", would prevent users from doing that. So they resort to CKMM and then reset status using CKMHELP program to set the status to 10 and then release the new cost.  It works, but wreaks havoc on ML as a whole eventually.
    Hope my comments are useful for some!!!
    Cheers,
    TD

  • Internal error in FORM/FUNCTION CKML_F_BUILD_INDEX in position 1 with RC 4

    Hi,
    Whenever I am trying to post a GR against PO I am receiving the following error message:
    Internal error in FORM/FUNCTION CKML_F_BUILD_INDEX in position 1 with RC 4
    I am not able to understand what this message is telling.
    How to resolve. Pl suggest.
    Regds
    Amitava

    error is because of a program bug,
    fix can be found in OSS note 1015263

  • Internal error in FORM/FUNCTION CKMLKEPH_ROLLUP in position 2 with RC 4

    The order settlement terminates with the error Message no. MLCCS 099 "Internal error in FORM/FUNCTION CKMLKEPH_ROLLUP in position 2 with RC 4".
    The material ledger is active. The actual cost component split is active. I want to  carry out the order settlement for one plants.
    With the same production material no.in the plant. There are many other productin order are settled in thid period. But, only one production order got the error message, why?
    I knew that I could change the Price determ. (in material master) from 3 Single-/multi-level to 2          Activity-related, then I can continute settlement transaction in CO88. But , I want to know what's wrong this the order. What should I check about the order. Why other orders are settled without error with the same material no, and  plant.
    I had check about SAP note 711416 & 729901 & 523100 & 623701 & 653523, those can't slove my problem in CO88.

    Thanks for your answer.
    But, I have two production orders product the same material in the same plant and  will be settled in this period. Both of those two orders were consumed material in 3 months ago. But, only one of them were terminated with error message in CO88. Why? How can I find out the difference between those two orders? They seems the same.
    For SAP note 623701 & 871926 & 867755, I think we already implemented those. I had found program "MLCCS_KO88_TREATMENT " in SE38. And, I can find the message 013 & 015 in message class MLCCS. So, do you have other commendations?
    Do you know how could I check about "Display order history" that mentioned in note 86775. Which T-code should I go to?
    Thanks a lot.

  • Internal error in LMLCCS_UPDATEF02 LCL_DB method get_normvector position A with RC 1 when VL31N processing only

    HI Everyone,
    I have mentioned error (Internal error in LMLCCS_UPDATEF02 LCL_DB method get_normvector position A with RC 1) only when I try to process IB GR in transaction VL31N.
    This problem does not occur in other Material related transaction.
    The Plan that we have problem was created many years ago and also ML was activated at that time.
    We did not any changes to ML settings since.
    I had revived followings notes:
    639675 - Initialization of the actual cost component split
    710808 - Activating actual cost comp split: check actual costing
    584904 - MIRO: no procurement alternative/wrong price diff in ML
    Seems like first one fit our problem the best, but in our cases we do not activated component split after the material ledger production startup and also we do not have such problem besides VL31N. In addition using above solution, even try, would lead to lost of historical data which we would like to avoid.
    Does anyone faced similar issue and have an idea how to deal with this?
    Thanks,
    Rafał

    Hi Felipe,
    Raise an message to sap.When you are getting this dump.
    Regards,
    Madhu.

  • KO88:Internal error in FORM/FUNCTION CKMLKEPH_ROLLUP in position 2 with RC

    hi,expert,
       When i settle production order , it issue MLCSS099 error.
       The message is ' Internal error in FORM/FUNCTION CKMLKEPH_ROLLUP in position 2 with RC 8'.
       The report 'MLCCS_KO88_TREATMENT' can not solve the problem.
       How to correct this?
      Thanks for advance.
    Tony

    Hi Tony,
    The error during the order settlement is produced because in earlier
    periods the cost component split for standard price is missing
    for the materials involved in the order that you are trying to settle
    with KO88.
    Please, change the settings in report MLCCS_KO88_TREATMENT to treatment
    option "S" for this order as explained in the note 623701.
    You need to delete the existing entry settings in program
    MLCCS_KO88_TREATMENT first.
    Afterwards, it should be possible to maintain the new settings for
    period ?/2011 (treatment type 'Split Delta by S price').
    Therefore, the steps should be:
    1. Delete the existing entry in program MLCCS_KO88_TREATMENT
       (-> processing type: delete settings), for the company code
       and period X/XXXX.
    2. Maintain option = 'Split Delta according to Standard Price,'
       with report MLCCS_KO88_TREATMENT for the orders that are causing
       the problem and period X/2011.
    I hope this helps you to solve the problem.
    Kind regards,
    MLM

  • 'Abnormal program termination.An internal error has occured.'

    Hi all... i have a problem when i'm in the middle of infra installation (74%) and then this popup message appears and stop my installation 'Abnormal program termination. An internal error has occured. Pls provide the following files to Oracle support:
    "/oraias/oraInventory/logs/installActions2010-08-18_11-03-52AM.log"
    "/oraias/oraInventory/logs/installActions2010-08-18_11-03-52AM.err"
    "/oraias/oraInventory/logs/installActions2010-08-18_11-03-52AM.out"
    i have tried several ways and many times to reinstall, to solve this error but still the result is still failed. i've tried to follow metalink suggestion by Edit the PATH, CLASSPATH, and LD_LIBRARY_PATH environment variables so that they do not reference any Oracle home directories, try to transfer again the software installation to directory server and extract from cpio files(i thought maybe the software might be corrupted) but the result is still same, stuck at the same place..! if any of you have experienced this before or have any idea on which setup do i have to look again, pls reply me ya. pls help and your help is very much appreciated.thanks in advanced.

    Hi, welcome to the forums!
    Have you already added the new node to Clusterware?. Have you followed all the steps detailed on the documentation?
    The note *How to Add Node/Instance or Remove Node/Instance in 10gR2, 11gR1 and 11gR2 Oracle Clusterware and RAC [ID 1332451.1]* is a must read, which points to the public documentation.
    If you already did that previous steps, you can enable a more detailed logging for the addnode execution with the parameters "-debug -logLevel finest", and setting this variables before running it again:
    export SRVM_TRACE=true
    export SRVM_TACE_LEVEL=2Regards.

  • Internal error in FORM/FUNCTION OUTSPLIT_SCLAE_UPDOWN in position 1 with RC

    Hi All,
    when I try to do MFBF with reporting points I'm getting error "internal error in FORM/FUNCTION OUTSPLIT_SCLAE_UPDOWN in position 1 with RC4" can anybody give me some idea to how to comeout of this error.
    Thanks and Regards
    Ramana

    we have contacted SAP and they have resolved the issue.
    Regards
    Ramana

  • System error in program Constiuent Assembly - internal error

    Hi,
    This is regarding the query execution, we have three variables in the selection screen, We have one variable for hierarchy selection from Constiuent Assembly.
    I am facing an issue while executing the query in BEX analyzer.Once i fill all the selection criteria in variable screen, I am getting an error saying that "System error in program Constiuent Assembly "
    Can anyone please suggest what could be the reason for this error?
    Please find below the error details.
    Diagnosis
    This internal error is an intended termination resulting from a program state that is not permitted.
    Procedure
    Analyze the situation and inform SAP.
    If the termination occurred when you executed a query or Web template, or during interaction in the planning modeler, and if you can reproduce this termination, record a trace (transaction RSTT).
    For more information about recording a trace, see the documentation for the trace tool environment as well as SAP Note 899572.

    Hi,
    May be the selection variable is not correct or corrupt.
    Use any other slection variable for hierarchy object.
    I hope it will help.
    Thanks,
    S

Maybe you are looking for

  • [SOLVED] Self-hosted file syncing options?

    Relevant previous threads and/or posts: * https://bbs.archlinux.org/viewtopic.php?id=172887 * https://bbs.archlinux.org/viewtopic.php … 3#p1478523 I think this is where this would go (other likely sections include "Applications & Desktop Environments

  • Satellite A25-S279: How to reinstall XP with Ghost DVD without internal drive

    I have tosbhia satellite a25-s279 and the toshiba ghost dvd. My internal dvd drive is broken (w/ some difficult, it can play some audio cd's some of the time. it doesn't recognize any cd-rom nor dvd). I also have external pioneer dvd writer dvr-s606

  • Importing multiple Word docs into InDesign

    Hi there Is it possible to import multiple Word documents into a single InDesign text frame all at once? I have 20 files that all flow sequentially so was wondering if -- by selecting them all in Place window -- they would all be brought in one after

  • Type not displaying on website

    After I publish my muse project to the web, on either my server on in catalyst, when page initially comes up, the type is not being displayed. If I refresh the page, it does appear. ( but I can't very well tell my viewers to do this to view my websit

  • Import Informix data into Oracle

    Hi. We have an Informix 7.25 SE database and we need to schedule daily imports of some of its tables into an Oracle 10g database on Solaris. The databases are on different machines. Thank you for your help.