Misc transactions running total turns blank when using different exp type

Hi,
I would like to ask for some advise on how to fix this issue:
When entering miscellaneous transaction with 2 different expenditure type (Labor and Material) the running total will be blank. But if we enter the same expenditure type (both Labor or Material) the running total will have values.
Any idea how to fix this? Thanks!
Application: 11.5.10.2
Edited by: JulieAnn on Mar 27, 2012 11:21 PM

This was fixed by changing the "Pixel Format" in the catalyst control center to "RGB (Full RGB)".. Somehow it got changed to "YcBcr".
I removed the /etc/ati/amdpcsdb file that the fglrx driver likes to put settings in and did a fresh reinstall of catalyst-test and everything looks good now. Really no idea how the pixel profile got changed. Also noticed that my resolution was much lower than it should have been (which for some reason doesn't affect XBMC which runs in native resolution no matter what?), but that was an easy fix of adding Mode "1920x1080" to my Display section in xorg.

Similar Messages

  • QBE issue when using different db types

    Hello,
    Our ADF application has the ability to connect to the same schema but different backends (Oracle and SQL Server). I have successfully implemented switching the AM data source. I am running into a syntax issue when performing Query By Example for a table. The error is (Incorrect Syntax near "|"). In the VOImpl I overrode the function public String getViewCriteriaClause(boolean forQuery) and I can see the viewCriteriaClause is "( (UPPER(TransMasterEO.TMMessage) LIKE UPPER( ? || '%') ) )". This works when running against the Oracle instance but fails when running against the SQL Server instance.
    I implemented code to replace the "||" with "+" but then we fail on Oracle. Can someone recommend an approach to resolve?
    Running 11.1.1.6
    Thank you
    Rudy

    he different dbs yre using different sql flavors. This is causing trouble if you change the connection to a db which is using a different flavor. I'm not aware that you can change the flavor used to build the queries to, but you can implement your own sqlbuilder which may just extend from the one for hte right flavor and then build the sql through the right class.
    Check http://jobinesh.blogspot.com/2013/02/customizing-sql-builder-class.html for more info on how to change the sqlbuilder.
    Timo

  • TS1398 my iphone turned off when using wifi

    my iphone turned off when using wifi

    That sounds like you have internal damage in the SIM card slot. Try taking the phone to an Apple store for evaluation. Make a genius bar appointment first at http://apple.com/retail.

  • Do IMAQ Cast Image or IMAQ Linear averages give different results when using different computers that are running under Windows XP ?

    Hello
    I'm currently developping an image processing algorithm using Labview 7.1 and the associated IMAQ Vision tools. After several tests, I found a weird result. Indeed, I put the labview algorithm - including the IMAQ VI on the library to get sure that I use all the time the same VI - on my memory stick and used it on two different computers. I tested the same picture (still in my memory stick) and had two very different results.
    After several hours trying to understand why, I found that there were a difference between the results given by both computers at the very begining of the algorithm. Indeed, I used a JPEG file.
    To open it, I first create an Image with IMAQ Create (U8). Then, I open it.
    Then in my first sub-VI, I use IMAQ Cast Image to be sure that the picture is a U8 grayscale picture.
    Right after that, I use the IMAQ Linear Averages. The results of this VI are different on the two computers.
    I tried several time on the same picture : one computer always give me the same result but the two computers give me a different result. So there is no random variable on the results.
    So my question is : Do IMAQ Cast Image or IMAQ Linear averages give different results when using different computers that are running under Windows XP ?
    My bet is on IMAQ Cast Image but I'm not quite sure and I do not undestand why. The labview and IMAQ are the same on both computers.
    The difference between the two computer are above :
    Computer 1 :
    Pentium(R) 4 CPU 3.20GHz with a RAM of 1Go. The processor is an Intel(R).
    The OS is windows XP Pro 2002
    Computer 2 :
    Pentium(R) 4 CPU 2.80GHz with a RAM of 512Mo. The processor is an Intel(R).
    The OS is windows XP Pro 2002.
    If anybody can help me on this problem, it would be really helpful.
    Regards
    Florence P.

    Hi,
    Indeed it's a strange behaviour, could you send me your VI and your JPEG file, (or another file that reproduces) so that I could check this inthere ?
    I'll then try to find out what's happening.
    Regards
    Richard Keromen
    National Instruments France
    #adMrkt{text-align: center;font-size:11px; font-weight: bold;} #adMrkt a {text-decoration: none;} #adMrkt a:hover{font-size: 9px;} #adMrkt a span{display: none;} #adMrkt a:hover span{display: block;}
    >> Découvrez, en vidéo, les innovations technologiques réalisées en éco-conception

  • Can I disable the "corners" that turn down when using Parallels?

    Can I disable the "corners" that turn down when using Parallels?

    "Auto Save" is Apple's term, I guess. Its controls are so well-hidden I'm flying blind here.
    But as I put it in a note to a magazine dedicated to Apple:
    I think Auto Save is one of the dumbest things Apple has ever come up with -- oh so typical of what Bill Gates used to give people: lots of extra stuff no one ever asked for, and no one at his company ever thought through.
    Say there's a conflict with a program or two I'm trying to use. Machine locks up. I force quit and shut down -- probably without ever seeing the option of stopping Auto Save.
    When I open up again, what am I faced with? Yup, exactly the same mess I just tried to get away from.
    Boo, Apple!

  • Device gets turned off when using data on mobile

    device gets turned off when using data on mobile... and not responding,i.e., if we hold the power button also there was no response,not getting on... when I connect it to charger,after 10min it gets automatically turning on.otherwise no chance to use the device..sometimes it gets off at 25%, sometimes at even 72% battery...seems it might be a severe problem..please suggest a solution..

    This might help:
    http://helpblog.blackberry.com/2013/02/restart-blackberry-z10/

  • Samsung 205BW goes blank when using DVI

    Hi
    I have a G4 Mac Mini. I recently purchased a [url="http://komplett.ie/k/ki.asp?sku=322266"]Samsung 205BW 20in widescreen LCD monitor[/url].
    I connected it via the DVI port on my mini with the DVI cable that came with the monitor and it seemed to work great but occasionally the screen will flick black as if there was nothing connected to it. It happens most noticeably when I go from a fullscreen quicktime video to the desktop or if I activate Expose. Also if the Mini goes to sleep and I try to wake it the screen stays black and I either have to reboot or change to using the VGA cable.
    The monitor works perfectly if I use a DVI-VGA adaptor and connect to the VGA port on the monitor but I'd prefer to use DVI.....
    I read on here of people using SwitchResX to change the settings for the monitor. I downloaded it but I don't really know what to input in the custom settings... perhaps someone here can help?
    Here is the DDC file from SwitchResX:
    =========================================================
    DDC block report generated by SwitchResX for display
    SyncMaster
    0 1 2 3 4 5 6 7 8 9 A B C D E F
    0 | 00 FF FF FF FF FF FF 00 4C 2D 1E 02 30 32 41 48
    1 | 03 11 01 03 80 2B 1B 78 2A EE 95 A3 54 4C 99 26
    2 | 0F 50 54 BF EF 80 B3 00 81 80 81 40 71 4F 01 01
    3 | 01 01 01 01 01 01 21 39 90 30 62 1A 27 40 68 B0
    4 | 36 00 B1 0F 11 00 00 1C 00 00 00 FD 00 38 4B 1E
    5 | 51 10 00 0A 20 20 20 20 20 20 00 00 00 FC 00 53
    6 | 79 6E 63 4D 61 73 74 65 72 0A 20 20 00 00 00 FF
    7 | 00 48 53 47 50 31 31 34 30 33 30 0A 20 20 00 6B
    Valid DDC block: checksum passed
    EDID Version........1.3
    Manufacturer........SAM
    Product Code........7682 (1E02) (021E)
    Serial Number.......1212232240
    Manufactured........Week 3 of year 2007
    Max H Size..........43 cm
    Max V Size..........27 cm
    Gamma...............2.20
    DPMS Supported Features:
    Active off
    Display type:
    RGB color display
    Input signal & sync:
    Digital
    Color info:
    Red x = 0.640 Green x = 0.300 Blue x = 0.150 White x = 0.313
    Red y = 0.330 Green y = 0.600 Blue y = 0.060 White y = 0.329
    Established Timings:
    800 x 600 @ 60Hz
    800 x 600 @ 56Hz
    640 x 480 @ 75Hz
    640 x 480 @ 72Hz
    640 x 480 @ 67Hz
    640 x 480 @ 60Hz
    720 x 400 @ 70Hz
    1280 x 1024 @ 75Hz
    1024 x 768 @ 75Hz
    1024 x 768 @ 70Hz
    1024 x 768 @ 60Hz
    832 x 624 @ 75Hz
    800 x 600 @ 75Hz
    800 x 600 @ 72Hz
    Manufacturer Reserved Timings:
    1152 x 870 @ 75Hz
    Standard Timing Identification:
    #0: 1680 x 1050 @ 60Hz (B300)
    #1: 1280 x 1024 @ 60Hz (8180)
    #2: 1280 x 960 @ 60Hz (8140)
    #3: 1152 x 864 @ 75Hz (714F)
    Monitor Description blocks:
    Descriptor #0 is Timing definition:
    Mode = 1680 x 1050 @ 60Hz
    Pixel Clock.............146.25 MHz Non-Interlaced
    Horizontal Vertical
    Active..................1680 pixels 1050 lines
    Front Porch............. 104 pixels 3 lines
    Sync Width.............. 176 pixels 6 lines
    Back Porch.............. 280 pixels 30 lines
    Blanking................ 560 pixels 39 lines
    Total...................2240 pixels 1089 lines
    Scan Rate............... 65.29 kHz 59.95 Hz
    Image Size.............. 433 mm 271 mm
    Border.................. 0 pixels 0 lines
    Sync: Digital separate with
    * Negative vertical polarity
    * Positive horizontal polarity
    Descriptor #1 is Monitor limits:
    Horizontal frequency range.......30-81 kHz
    Vertical frequency range.........56-75 Hz
    Maximum bandwidth unspecified
    Descriptor #2 is Monitor name:
    SyncMaster
    Descriptor #3 is Serial number:
    HSGP114030
    =========================================================
    thanks for any help!!
    Mac Mini G4 Mac OS X (10.4.9)
    Mac Mini G4 Mac OS X (10.4.9)

    I had the exact problem you report with my core duo Mac Mini connected to a Syncmaster 204B. This problem persisted when I returned the monitor several times to Samsung for replacement 204B's. They eventually upgraded me to a refurbished 204T and the problem disappeared.
    It seems to me that Samsung has some real problems with screen blanking when their monitors are hooked by DVI to certain Macintoshes. For anyone contemplating a Samsung monitor, I'd recommend another brand until it's known that this screen blanking problem has been resolved with all Samsung models.
    Mac Mini Core Duo   Mac OS X (10.4.9)   1 GB RAM

  • My iMac G5 Fans run at full speed when using regular everyday applications.

    When using just normal everyday applications such as using about 30 min of Safari to surf the web or maybe something else, my fans run at full speed. I have just got a new logic board replacing my old faulty one. How can I fix the fan problem?
    Thanks!

    Hi again Miriam,
    With more news for you and iMacG5 on the fans go crazy. I just got back my computer from the repair center. After more than a week under observation, the technician told me that they just couldn't replicate the problem. They had the computer running non-stop during all this time, not even allowingit to go to sleeo mode and nothing.
    The CPU fan never went beyond 2300 rpm (or so) and never went to sleep mode on and off by itself. Furthermore, they ran all possible tests and everything comes back as OK.
    Right now I have a movie running on the background, together with a photo processing software open and other smaller processes and the CPU fan is running at 4361 rpm !!! the temp of the CPU is 66.3 Celsius.
    Any thoughts??? It's really making me crazy because the computer was neverlike this and now it sounds like a hair dryer. I emphasized with them the fact that this just started after they changed the logic board and as coincidence after Ioaded the security update 2006_04. The technician told me it may be software related. If the computer doesn't go to sleep by itself, then he recommended to reload the operating system.
    Any comments appreciated.
    Zwirek

  • Images on Facebook do not appear when using different web browsers

    Images on Facebook do not appear when using Safari on my Macbook Pro (I've tried Google Chrome too with the same result).  This makes me think it's a setting within OS Mavericks that I'm missing.  I have not seen this issue on any other computers.  This only occurs on my, and others' profile pictures on my profile page and on the news feed, not photos that are posted in albums or on walls.  and yes, i have images enabled in Safari.
    In safari the images don't appear, and in their place is a small blue "?" square >>.
    In Chrome it appears as a broken image link >>
    Has anyone encountered this?  Is there a fix?  It is very annoying.

    Please read this whole message before doing anything.
    This procedure is a diagnostic test. It’s unlikely to solve your problem. Don’t be disappointed when you find that nothing has changed after you complete it.
    The purpose of the test is to determine whether the problem is caused by third-party software that loads automatically at startup or login, by a peripheral device, or by corruption of certain system caches. 
    Disconnect all wired peripherals except those needed for the test, and remove all aftermarket expansion cards. Boot in safe mode and log in to the account with the problem. Note: If FileVault is enabled on some models, or if a firmware password is set, or if the boot volume is a software RAID, you can’t do this. Ask for further instructions.
    Safe mode is much slower to boot and run than normal, and some things won’t work at all, including sound output and  Wi-Fi on certain models. The next normal boot may also be somewhat slow.
    The login screen appears even if you usually log in automatically. You must know your login password in order to log in. If you’ve forgotten the password, you will need to reset it before you begin. Test while in safe mode. Same problem? After testing, reboot as usual (i.e., not in safe mode) and verify that you still have the problem. Post the results of the test.

  • Unsatisfied Link Error when using Oracle OCI (Type II) driver

    Using Oracle OCI (Type II) driver on HPUX with Oracle 9.2.0.4.
    If when creating a connection pool via the console, using the Oracle OCI (Type
    II) driver, you get the error "Unsatisfied link error with library libocijdbc9.sl
    or format error" then check that the library included in the SHLIB_PATH is pointing
    at the $ORACLE_HOME/lib32 directory and not just the $ORACL_HOME/lib

    We do not offer a JDBC driver for Linux in version 5.1. In version 6.0,we
    do offer a type 4 driver for Linux.
    In version 5.1, I suggest trying the platform independent type 4 JDBC driver
    available for free from Oracle. It is supported (as is any JDBC driver)
    with WebLogic Server. To download it:
    Go to http://www.oracle.com and select the "Download" option.
    From the resulting page, use the "Select Utility or Driver" dropdown to
    select Oracle JDBC drivers
    From the resulting page, scroll down a little (since SQLJ stuff appears at
    the top).
    Or, to go directly there:
    http://technet.oracle.com/software/tech/java/sqlj_jdbc/software_index.htm
    Thanks,
    Michael
    Michael Girdley, BEA Systems Inc
    Learning WebLogic? Buy the book.
    http://www.learnweblogic.com/
    "Michael W. Warren, Sr." <[email protected]> wrote in message
    news:[email protected]..
    I have installed WebLogic 6.0 on Solaris platform and verified that the
    server comes up
    and that I can connect to it via Netscape. Next step was to verify
    installation of WebLogic
    jDriver for Oracle. When I run the following:
    java utils.dbping ORACLE scott tiger
    I get the following error:
    Starting Loading jDriver/Oracle .....
    Error encountered:
    java.sql.SQLException: System.loadLibrary threw
    java.lang.UnsatisfiedLinkError
    with the message
    '/ldatae/bea/wlserver6.0/lib/solaris/oci816_8/libweblogicoci37.so:
    ld.so.1: /ldatae/bea/jdk130/jre/bin/../bin/sparc/native_threads/java:
    fatal: libgen.so.1: open failed: No such file or directory'.
    at
    weblogic.jdbcbase.oci.Driver.loadLibraryIfNeeded(Driver.java:202)
    at weblogic.jdbcbase.oci.Driver.connect(Driver.java:57)
    at java.sql.DriverManager.getConnection(DriverManager.java:517)
    at java.sql.DriverManager.getConnection(DriverManager.java:146)
    at utils.dbping.main(dbping.java:182)
    Anyone seen this? Help!!!
    Thanks in advance
    Mike Warren, Sr.
    [email protected]

  • Dbms_crypto - avoid error when using different key in lower environment

    Hello Experts,
    We are using Oracle 11.2.0.2. We are planning to implement dbms_crypto to encrypt few columns. We clone the data from production to lower environment ( DEV, QC).
    For the lower environments, we do not want to get the sensitive data from production and do not plan to use same key. Rather than getting an error when using differnt key, is it possible to get a different resultset back.
    In other words, we want the implementation to be same across environments but want to use a diffent key in lower environment and get different result (or garbage).
    Any suggestions would be greatly appreciated.
    While testing this logic, I am getting following error when using differnt key to decrypt. It works fine if I use same key.
    Error at line 1
    ORA-28817: PL/SQL function returned an error.
    ORA-06512: at "SYS.DBMS_CRYPTO_FFI", line 67
    ORA-06512: at "SYS.DBMS_CRYPTO", line 44
    ORA-06512: at line 19
    DECLARE
      l_credit_card_no    VARCHAR2(19) := '1234 5678 9012 3456';
      l_ccn_raw           RAW(128) := UTL_RAW.cast_to_raw(l_credit_card_no);
    l_key               RAW(128) := UTL_RAW.cast_to_raw('abcdefgh');
       l2_key               RAW(128) := UTL_RAW.cast_to_raw('12345678');
      l_encrypted_raw     RAW(2048);
      l_decrypted_raw     RAW(2048);
    BEGIN
      DBMS_OUTPUT.put_line('Original  : ' || l_credit_card_no);
      l_encrypted_raw := DBMS_CRYPTO.encrypt(src => l_ccn_raw,
                                             typ => DBMS_CRYPTO.des_cbc_pkcs5,
                                             key => l_key);
      DBMS_OUTPUT.put_line('Encrypted : ' || RAWTOHEX(UTL_RAW.cast_to_raw(l_encrypted_raw)));
      l_decrypted_raw := DBMS_CRYPTO.decrypt(src => l_encrypted_raw,
                                             typ => DBMS_CRYPTO.des_cbc_pkcs5,
                                             key => l2_key); --**Using different key to decrypt
      DBMS_OUTPUT.put_line('Decrypted : ' || UTL_RAW.cast_to_varchar2(l_decrypted_raw));
    END;Thank you.

    If I understand what you are trying to do ... and I may not ... it is not going to work.
    SQL> DECLARE
      2   l_credit_card_no VARCHAR2(19) := '1612-1791-1809-2605';
      3   l_ccn_raw RAW(128) := utl_raw.cast_to_raw(l_credit_card_no);
      4   l_key1     RAW(128) := utl_raw.cast_to_raw('abcdefgh');
      5   l_key2     RAW(128) := utl_raw.cast_to_raw('zyxwvuts');  -- alternate key used to attempt a different decryption
      6 
      7   l_encrypted_raw RAW(2048);
      8   l_decrypted_raw RAW(2048);
      9  BEGIN
    10    dbms_output.put_line('Original : ' || l_credit_card_no);
    11 
    12    l_encrypted_raw := dbms_crypto.encrypt(l_ccn_raw, dbms_crypto.des_cbc_pkcs5, l_key1);
    13 
    14    dbms_output.put_line('Encrypted : ' || RAWTOHEX(utl_raw.cast_to_raw(l_encrypted_raw)));
    15 
    16    l_decrypted_raw := dbms_crypto.decrypt(src => l_encrypted_raw, typ => dbms_crypto.des_cbc_pkc
    s5, key => l_key1);
    17 
    18    dbms_output.put_line('Key1 : ' || utl_raw.cast_to_varchar2(l_decrypted_raw));
    19 
    20    l_decrypted_raw := dbms_crypto.decrypt(src => l_encrypted_raw, typ => dbms_crypto.des_cbc_pkc
    s5, key => l_key2);
    21 
    22    dbms_output.put_line('Key2 : ' || utl_raw.cast_to_varchar2(l_decrypted_raw));
    23  END;
    24  /
    Original : 1612-1791-1809-2605
    Encrypted : 3534443342333642353141363846384237463732384636373943374630364234323243334539383042323135
    Key1 : 1612-1791-1809-2605
    DECLARE
    ERROR at line 1:
    ORA-28817: PL/SQL function returned an error.
    ORA-06512: at "SYS.DBMS_CRYPTO_FFI", line 67
    ORA-06512: at "SYS.DBMS_CRYPTO", line 44
    ORA-06512: at line 20

  • Error when using RTF as type of web report

    When I use RTF as type of web report ,the program will exceptionly terminate with exceptoin.When I use html,Pdf format,it work well.Who can help,Thanks in advance.

    It seems your browser is not properly configured to handle RTF content. You can try to load a local RTF directly into your browser and see if that works.

  • History Attributes when using Custom Authentication Type

    assigned all History Attributes (in the Entity Object Editor) to my audit columns.
    During run time, I find only Created By is assigned the SYSDATE, and Created On, Modified On, and Modified By are null.
    I am using Custom Authentication Type.
    I have read that the History Attributes only work the the JAAS authentication type. Appreciate any one confirming this.
    Also, how do you implement History Attributes if you are using the Custom Authentication Type? Do you need to write Java code?
    Thanks.
    John

    Hi,
    confirmed it only works with container managed authentication performed through JAZN. You can't use this with custom security as otherwise this feature could be overwritten. Still you can provide your own implementation:
    - create a custom table
    - use the setAttr method on the RowImpl class of a VO to store the username
    Frank

  • Project changes when using different pc's

    ok i had using pro 4 a project saved on  pc one
    i then opened it up on another pc [pc 2] where i added some title pages
    then saved the project on pc2 and copied the whole saved folder back to pc one
    when i opened the copied project on pc one [using pc one] the title fonts have changed
    is there some issue when using more than one pc to work on one project ???
    oh i forgot pc one = win xp and pc2 = windows 7 !!!
    cheers

    ok the font used was MV Boli
    on both pc when i look in titler they both say MV Boli
    they just look totaly different
    other thing different between the two is :-  the font templates used and saved on pc 2
    are not showing up when opend on pc 1

  • Error when using 557 movement type to remove stocks from intransit

    Dear All,
    We have some stocks left in intrasit where we use only inventory management to do this stock transfer(ie. we are not using STO),now we want to remove this stock from intransit. When i tried to use movment type 557 I got an error (Deficit of PL Stock in transit 10 DZ : CHS10088 2KUR 0000000867) with message number M7021. I cross this material with mb52 to find the avalability of this intransit stock and found that it  is available at given plant but with out a batch number. When I tried to use this movement type it asks for a batch number so i have given an available batch number. Can you please help me to remove this stock from intransit.
    Thanks & Best Regards,
    Chameendri

    Hi
    the movement types 557 ( and 558 ) can only be used to update intra-company
    transit stock which is saved in MARC-TRAME. IF you are using purchase
    orders  cross-company stock transfers, the transit stock is only a virtual transit stock what is calculated
    based on the purchase order history. So this issue cannot be addressed
    by changing the data in a stock table.
    Are you using intra-company STO ?
    Please check carefully note 392205  that contains the report ZTRAME
    .Please see the following information:
    A report attached to the note 392205 tries to explain the stock in
    transit using the documents existing in the system. First verify the
    current stock in transit situation using the report ZTRAME as per the
    note 392205. This program tries to 're-calculate' the stock in transit
    based on the material documents and the purchase order history.
    Based on the results of the program the movement-types 557 and 558 can
    be used to correct the stock in transit (-> add or book out stock in
    transit).
    I hope this can be of help
    BR
    Nadia Orlandi

Maybe you are looking for