Mismatched input channels

Hi,
I have problem with Formula module. Mismatched input chanels: the time information or block length of the input channels do not match ...
My sampling rate 100kHz and Block size: 16384. I add my Worksheet.
Attachments:
nowy.DSB ‏32 KB

Sorry for the delay in responding. Happy New Year.
The two channels going into the forumla have different block size and sample rates. The Formula expects all data coming in to have the same sample rate, block size, and time stamp. 
The Statistics module outputs one value for a block of data. 
Your sample rate is 100 kHz, with a block size of 16384. The FFT module reduces the block size to 8192.
The Statistics module on Channel 0 is outputting one sample blocks with a sample rate of 6.1035.
The second channel going into the Statistics module is coming from the Block Average module. It is reducing the total number of blocks, keeping the sample rate in the block the same (100 kHz) and the block size the same, but the total number of blocks is reduced by 4. It then goes into the Statistics module, where it is reduced again, this time to a block size of 1 and a sample rate of 6.1035. BUT... there are fewer blocks, with gaps - the data channel is now tagged as  "triggered" which means that there are gaps in the data, it's not perfectly continuous.
This Chart Recorder image shows you the problem.
The real question.... what are you trying to do? 
- cj
Measurement Computing (MCC) has free technical support. Visit www.mccdaq.com and click on the "Support" tab for all support options, including DASYLab.

Similar Messages

  • I can't seem to get GB to recognize my Behringer X1222 USB Mixer. It will record, but shouldn't I be able to see and/or select which input channel(s) that I will record from? Can I record more than one channel at a time, and record multi tracks?

    I can't seem to get GarageBand to recognize my Behringer X1222 USB Mixer. It will record, but only on the generic "USB Input, without seeing or letting me select the input channel from the mixer. Can't find any drivers from Behringer. How do I getGB to "see" the mixer? Thanks, I'm a newbie to Macs in genreal, and recording...

    viiram wrote:
    It will record, but only on the generic "USB Input, without seeing or letting me select the input channel from the mixer.
    the x1222 includes a 2 channel audio interface, 2 channels are all you can get from it.
    the most you can do is record to 2 tracks at a time; skim this tute to see how:
    http://www.bulletsandbones.com/GB/Tutorials.html#allaboutrecording2tracks
    (Let the page FULLY load. The link to your answer is at the top of your screen)

  • Error in JMS Input channels

    Dear all,
    We have observed a peculiar issue.
    Some of the JMS Input channels are throwing this error:-
    "Error establishing JMS connection; error message: MQJMS2005: failed to create MQQueueManager for <IP>:<QM Manager>> MQJE001: An MQException occurred: Completion Code 2, Reason 2009
    MQJE016: MQ queue manager closed channel immediately during connect
    Closure reason = 2009; error code: MQJMS2005"
    Other JMS channels with the same configurations are working fine. But some JMS channels have this error.
    If any one has faced a similar issue, kindly share the steps to resolve the same.
    Thanks in advance,
    Younus

    Please ask the MQ Team to restart the MQ queue.I mean to stop and start again.
    We faced similar kind of issues and we even tried to restarting the JMS communication channel and MQ Queue.This solved our problem.
    As only one JMS channel is not working,there might be connectivity issues with JMS Queues..
    Try to restart the JMS Queue and JMS communication channel and see.

  • I have this problem,    Tag 'A2B0': Number of input channels is not correct.     Tag 'A2B0': Number of output channels is not correct.     Tag 'B2A0': Number of input channels is not correct.     Tag 'B2A0': Number of output channels is not correct.

    i have this problem,   
    Tag 'A2B0': Number of input channels is not correct.    
    Tag 'A2B0': Number of output channels is not correct.    
    Tag 'B2A0': Number of input channels is not correct.    
    Tag 'B2A0': Number of output channels is not correct.
    I work with Capture One Pro 7, photo editor
    what can I do to solve this problem?

    You may have better luck asking your question here: Capture One 7.x Software for Mac
    OT

  • How to set audio hardware input channels for narration & to what?

    Searched forum - hope I didn't miss solution for the following:
    Using PE3 in Windows XPSP3
    Tried for the first time to add narration to a project. Was using a stereo/microphone headset. Got nothing but noise. Could record in Windows recorder and Audacity. However, the microphone as part of the set would not work in Windows Audio Hardware Test Wizard. The set was using a sound chip on the motherboard.
    A friend of mine has the same OS, motherboard and is using PE3. He too had never tried adding narration - but tried with a USP connected set, and was successful.
    I removed my stereo set, and connected a USB set. To make sure all settings were reset, I did a cold reboot. The USB set worked in Windows Audio Test Wizard. I opened my project again, and in Edit/Preferences/Audio Hardware, clicked AIIO Settings. Unchecked the old set (Realtek) in both the Output and Input Ports area, checked the USB Audio Device, moved to the top of both lists.
    Then tried to add narration and got the error message "Your current audio hardware selection does not have any input channels. Please use Preferences>Audio Hardware to correct this problem.
    Thinking that maybe this was a preset for the project and couldn't be changed, I started a new project, no video, just tried to add narration, and got the same message.
    The entries in the columns in the ASIO Direct Sound for Full Duplex Setup menu for the USB Audio Device in the Input section are: 2048, 0, 1, 16, Yes
    The only one of these that seems to be able to be adjusted is the second number - the Offset (Samples). The Audio Channels number is set to 1 and doesn't seem to be changeable. Suggestions?

    When working with Audio in most NLE's, i.e. Premiere Elements, or Pro, there are basically three areas that can affect how the Audio is handled on one's system. First, there is the Sound settings in Windows (from Control Panel). Next, the Audio card/chip probably/possibly has a console to make settings at the card/chip level. Last, and these are really two locations, but I'm only counting them as one since they are both in the NLE - Edit>Preferences>Audio & Audio Hardware. This is where Steve is referring to. Check all settings, and I'd suggest doing so in the order that I listed them above: OS, Audio card, then Premiere. A Mute, or by-pass in the first two, can override the settings in Premiere, and you may have its setting correct, but still not be able to effectively use your hardware.
    The exact settings chosen will depend on the exact hardware that is properly installed. Without knowing all of your hardware and other settings elsewhere, one cannot give you a definitive answer. Ideally, in the settings drop-downs, you *should* see your hardware listed. Look closely, as these can be a bit cryptic.
    If you are still unable to get your hardware working properly, a fourth place to look would be Control Panel>System>Hardware>Device Manager for your Audio hardware. Check that Device Manager sees your hardware, and that it is working properly.
    If all is set up properly, but still not working, report back with exact specs on your system, including all of your Audio hardware. There are possibly some more steps that can be taken. I will not mention them now, as they *should not* be needed. If you do need further assistance, please list every option in all of the drop-down lists from Premiere, so we can know what your choices are.
    Good luck,
    Hunt

  • Two real input channels xy graph curve fitting

    i'm a new user with labview, now i have a problem with the xy graph
    i use two real input channels as the x and y axis of xy graph, but whatever i change the sample rate, the curve is so bad.
    i use a quene to mean the x,y data but the result is not true.
    there are the pic and vi. i hope anyone can give me some corrections or advice, thank you so much.
    Attachments:
    fitting xy graph.JPG ‏87 KB

    here is the vi.
    Attachments:
    xy_graph(lv8.2).zip ‏1296 KB

  • DIAdem: How to store the input channel information from the Analysis modules

    Hi,
    I would like to know if there is a way to store the input channel name(s) when executing modules from the Analysis Panel. For example, when I run an FFT on a set of data: x-channel: "[1]/Time" y-channel: "[1]/Voltage" , I would like to be able to store this information as a custom channel property in the output file (ex. "[1]/AutoSpectrum").  
    The only place I've found that contains this "history" information is in the log section of the Analyze Panel. However, I have not been able to figure out how to access the information in the Analysis log programatically through VBS scripting.
    Thanks

    Hi Brad,
    So here's where I'm struggling. My tool is more a set of tools. I have created custom bars that launch the appropriate dialog box for each tool. Let me give you and example of the kind of work flow I that might be used:
    The user loads up a TDM file or imports data using a DataPlugin. Then, they launch my tool for going through each channel and adding custom properties (sensor type, sensor location, etc). Once all properties have been applied to the channels they close that tool. Now they fire up the Smoothing module in ANALYSIS and save the result as a new channel. Next, they launch my tool for computing the Shock Response for that event. When the user has the desired output, they run my plotting SUD. This is where they can select which report template to use and which channels to plot. The selected channel(s) used for plotting doesn't have all of the custom properties that we taged in the original data channels.
    As you can see, the process involves using some of my own custom SUDs where I can keep track of everything but also allows the user to use any of DIAdem's native functions. This is where I am struggling to be able to keep track of the channels used as input. I can "see" the info I need listed in the log section of the ANALYSIS Panel but can't pragmatically access it (the info in the main display window). It would be really handy if this info was automatically stored in the channel properties of each output channel.
    I guess my only option is to (in the plotting SUD) not only ask the user for the channels to plot, but also ask them to select the coresponding original channels that have the custom properties.
    James

  • Multiple input channels with following start task VIs

    Hello everybody
    I have this Vi, trying to acquire two input signals. I get the error 50103 which is because of "Concurrently running two or more analog input or analog output tasks".
    obviously, I should combine them into one task but here is the problem:
    first: I want one of them to be started after the other one. I dont want them to be started atr the same time.. i dont know how to start them sequently on one task..
    second: I want to send the pulse from the analog comparison event of the first input signal to the second one. but i dont know how i can do that when im having both channels in one task.
    thanks..

    Dear  RavensFan
    thank you for your responce
    about the second question:
    once the trigger condition set up has been met an analog comparison event pulse is output from the analog trigger circuitry and is then available to the AI, AO and Counter Circuitry.
    then I need this pulse signal as the source of triggering for acquiring another input singnal I will add to my Vi later . if you look at my VI, i have connected a analog comprison event to the second input channel samle clock,,, i'm not sure if i'm doing the right thing here or not..
    what i was trying to do is that i want this vi to show me the output signal of the analog comparison event which carries the information about the times that my trigger settings has occured..
    actually, in the second inut channel, i wanted to make a graph that shows me the times that my first signal has crossed zero points. (which is obvious in my trigger setting)
    Is there any way i dont have to combine my input signals in one task and get rid of the error?
     

  • 6-input channels on Audigy 2 Platinnum

    Does anyone to know, if I could to record from 6 independent channels to 6 tracks in realtime, for example in Cakewalk or Cubase SX(multitrack audio-studio software)?
    I'm thinking about buy it for that purpose.
    Thanks for information.

    Hi
    At least 6 mono channels.
    Use Creative ASIO drivers on Sonar/Cubase so you get more than one stereo (mono L/R) input channel to choose from. Also you perhaps need a (good) pre-amp/mixer to get all sources connected separately into Audigy inputs (using '2 mono to stereo' jack adapters).
    .jtp

  • Measurement output keeps drifting, even when the input channel are shorted out.

    Dear Technical Engineer,
    Greetings!
    Currently, we are conducting a voltage measuring experiment with your DAQ card "NI PCIe-6353". The voltage we are concerning is a slow variable ranging from 0-20mV.
    However, we met some problems operating your device.
    1.When the input channel is vacant (no connection to any voltage output), the measurement curve displayed in the test panel (built in your driver) keeps drifting (from some point to -10V, then slowly upwards to +10V, then downwards...), but not stays at 0V.
    2.The moment we connect the input channel to a DC stabilized power supply (2V), the measurement curve displays a quick step, but not step to 2V. Then, it continues to drift downwards.
    3.When we short out the input channel (for example, connect “33 A1” with “32 A1 GND”), the measurement output still keeps drifting, but not displays 0. 
    Thus, we wonder if some settings should be regulated, or if there is something wrong with our operations, or there is an additional grounding option that we missed, or the device just breaks down. Could you please give us your valuable suggestions?
    If you need any more informations, please do not hesitate to contact us (email:[email protected]). Thanks for your time and attention! We are looking forward to your kind reply.
    Best,
    Xianke

    Hi Xianke,
    It sounds like you may have your measurement configured in differential mode. If so, then you should read 0V when you short pin 66 AI1- to pin 33 AI1. Do you see this same behavior on other channels?
    It looks like the default input configuration is differential, so you can also leave your wiring as it is, and change to RSE.
    Trevor B.
    PSE
    National Instruments

  • What input channel should my sony bravia tv be on for apple tv to work?

    I am trying to plug our new apple tv into our Sony LCD Digital Color TV (KDL-V26XBR1) but I the tv instructions do not explain which input channel the tv needs to be set to to watch appletv.  I have purchased an HDMI cable which is plugged into the apple tv and the television.  Help...I'm a bit tech hopless.

    If you only have one HDMI connection, cycle through your input options until you reach HDMI, press any button on your Apple Tv and in a few moments you should see the Apple TV interface.
    If you have more than one HDMI connection, each HDMI port will usually have a number alongside it, discover the number of the HDMI port you are using and cycle to that input......

  • Writing more than 16 analog input channels into a single file

    In DasyLAb 10.0, how can I WRITE more than 16 analog input channels (using WRITE DATA block) in one single file? I do not want to use 2 WRITE blocks, as I want all my data samples in one single file.

    Another few questions:
    In the merge block, what is the difference between Blockwise mode and Sample mode?
    Also, now that I am using the Merge blocks (2 inputs to 1 output) to combine my analog inputs; how would I have to modify my WRITE block so that I can ultimately obtain both my inputs to be written in the same file in seperate columns. Could you please explain the settings I need to make on the WRITE block.
    Thanks!

  • LE doesn't receive additional input channels

    I'm trying to add four more input channels to my recording system and Logic Express is not registering any signal.
    My main unit is a MOTU 896HD and has been working very well for the past year. I recently added a Presonus Digimax 96K and connected it via the ADAT Lightpipe.
    Using the MOTU Cuemix console, all inputs are functioning and operating well. I've tested the unit and have gotten output from all available channels (8 from the MOTU, 8 from the Digimax). The problem is that Logic is not showing any signal from input channels 9 - 12 (I know that Logic Express is limited to receiving 12 simultaneous input channels).
    I assume that LE will simply add the first four channels of the Digimax to the list of available input channels for a total of 12 channels.
    The drop-down menu in the I/O selector show 12 inputs and I can select one of those tracks, but no signal is received.
    Any help is greatly appreciated.

    So here's what I found out, on my own, by digging under the hood:
    The Mac uses the "Aggregate Device" through the Audio MIDI Setup utility. When I checked it out (last night, for the first time) it showed the MOTU 896HD with 20 inputs and 22 outputs. The Mac OS had already recognized the increase of channels introduced by the DigiMax. So then I knew my problem was within Logic (what a lousy name for such a confusing program).
    A friend of mine, who records with MOTU Digital Performer, suggested that my problem was a "routing loop." So I looked for proof that channels 9-12 in Logic were not actual recording channels. This proved to be the case once I understood how to read the device info in the Audio MIDI Setup utility. It turns out that tracks 9 & 10 are for AES/EBU and tracks 11 & 12 are for "Mix1". There was my faulty routing loop. Tracks 11 & 12 were the ones that gave me squealing problems.
    Tracks 13 - 20 were correctly labeled "ADAT" in the Audio MIDI utility.
    So, I went back to AudioDesk (free with the MOTU 896HD), where I have been having great success in setting up my live recording channels (i.e., no feedback, good signals on all channels). When I create a new track in AudioDesk, it's simple to select the correct input channel. In other words, input 9, 10, 11, & 12 were actual input channels, not an AES/EBU signal or a "Mix1" signal. It was in the program's "Audio Monitor" panel that I saw that input signals for tracks 9-12 were actually from hardware channels 13-16.
    I went to bed and considered my problem solved.
    The bummer from this lesson is that Logic Express accepts only 12 inputs. To access any inputs (hardware channels) above #12 I must either upgrade to Logic Pro or switch to a new recording software. I've spent about $200 on Garageband plug-ins for MIDI instruments and feel just a little peeved that I'm in this predicament. 8^P
    At this point, I'm not a fan of Logic. The product name should be "Sucka!", with the tag line "You upgraded from GarageBand and expected a similar interface, workflow and ease of use. Ha!"
    I hope my little lesson helps someone else in the future.

  • How to do register-level programming for NI6025E when I want to acquire single scan incuding multiple input channels?

    How to do register-level programming for NI6025E when I want to acquire single scan incuding multiple input channels?

    Thanks, Alan, I think I indeed need to combine aiex1.cpp and aiex2.cpp. I made a change to Configure_Board of aiex1.cpp  as follows:
    //Call this function to configure board options.
    void Configure_Board(tSTC *theSTC,tESeries *board)
     //Clear configuration memory
     theSTC->Write_Strobe_0.writeRegister(0x0001);
     //Clear ADC FIFO
     theSTC->Write_Strobe_1.writeRegister(0x0001);
     //Writing to Config_Memory_High_Register for channel 1 settings
     board->ConfigFifoHigh.setChannel(0);
     board->ConfigFifoHigh.setBank(0);
     board->ConfigFifoHigh.setChannelType(board->ConfigFifoHigh.kChannelTypeRSE);
     board->ConfigFifoHigh.flush();
     //Writing to Config_Memory_Low_Register for following channel 1 settings
     board->ConfigFifoLow.setLastChannel(0);
     board->ConfigFifoLow.setGeneralTrigger(0);
     board->ConfigFifoLow.setGain(board->ConfigFifoLow.kGain001_0);
     board->ConfigFifoLow.setPolarity(board->ConfigFifoLow.kPolarityBipolar);
     board->ConfigFifoLow.setDither(0);
     board->ConfigFifoLow.flush();
     //Writing to Config_Memory_High_Register for following channel 0 settings
     board->ConfigFifoHigh.setChannel(1);
     board->ConfigFifoHigh.setBank(0);
     board->ConfigFifoHigh.setChannelType(board->ConfigFifoHigh.kChannelTypeRSE);//RSE mode
     board->ConfigFifoHigh.flush();
     //Writing to Config_Memory_Low_Register for following channel 0 settings
     board->ConfigFifoLow.setLastChannel(1);
     board->ConfigFifoLow.setGeneralTrigger(0);
     board->ConfigFifoLow.setGain(board->ConfigFifoLow.kGain001_0);
     board->ConfigFifoLow.setPolarity(board->ConfigFifoLow.kPolarityBipolar);//BIPOLAR
     board->ConfigFifoLow.setDither(0);
     board->ConfigFifoLow.flush(); 
     return;
     and a change to test(iBus *bus):
    do
      uStatus = theSTC->AI_Status_1.readRegister();
      if (!((uStatus & 0x1000) == 0x1000))
        uValue[i] = board->AIFifoData.readRegister();
       i++;
     } while(i<1);
     printf("Value %d is %6.2f\n",0,FindADDouble(uValue[0]));
     printf("Value %d is %6.2f\n",1,FindADDouble(uValue[1]));
    but it doesn't work, why?
    How shoud I do?

  • Acquiring a waveform from the input channel

    Hi, while I am trying to acquire teh waveform from the input channel,
    it is not showing up in Labview "waveform graph", but the same
    waveform is seen on the oscilloscope. I am using NI PCI 6052-E DAQ
    board.

    Greetings Amu,
    How have you configured the PCI-6025E? Is it configured for
    differential readings or single-ended readings?
    By default, the configuration of the device will be differential,
    which means that two input channels are used for every input signal.
    When configured in differential mode, you need to connect the positive
    terminal of the signal to channel X and the negative terminal of the
    signal to channel X+8. For reading a differential signal from channel
    0, you will connect the positive terminal of the signal to channel 0
    (pin 68) and the negative terminal of the signal to channel 8 (pin
    34).
    I would suggest to use the Measurement and Automation Explorer (MAX)
    software to test the signal before going to LabVIEW. Open MAX and go
    to the devices and i
    nterfaces folder. The PCI-6052E should be located
    in this folder. Right-click on the PCI-6052E and select test panels
    and you will be able to test the input signal here. You can change
    the mode to continuous and set an sampling rate in the test panels as
    well.
    Once you can view the signal in the test panel of MAX then I would
    suggest to move to LabVIEW. Search for the shipping example entitled
    'Cont Acq&Chart (buffered) VI' which is a continuous analog input
    example. Select the device number, channel number, and scan rate and
    run the VI.
    For more information on connecting your signals to the PCI-6052E I
    would suggest to refer to chapter 4 of the user manual. I've linked
    it below for your reference.
    NI 6052E User Manual
    http://digital.ni.com/manuals.nsf/webAdvsearch/552436964E347DAF86256BDE00670E9B?OpenDocument&vid=niwc&node=132100_US
    I hope this helps.
    Let me know if you have any additional questions regarding this issue.
    Regards,
    Todd D.
    NI Applications Engineer

Maybe you are looking for

  • Forms Help for Multiple Use Forms

    I need some help on a forms question. I have created several forms that I wanted to use in Adobe Pro for email based review. I have been using the base forms, adding the information (these are budget forms)then saving the forms with a different name.

  • Poor WiFi on Edge 15

    I purchased the Edge 15 two days ago from Best Buy. Brought it home and did the setup and it seemed slow. Not the processor, but the downloads. I ran a speed test and was getting 1 Mbps download but 5 mbps upload. I pay for up to 50 Mbps. I checked t

  • Getting error " Conversion failed when converting date and/or time from character string."

    Hello Experts, I am getting the above error, when i try to execute the query.  DECLARE @START AS DATETIME DECLARE @END AS DATETIME SET @START = CONVERT(VARCHAR(10), GETDATE()-1,101) + '00:00:00' SET @END = CONVERT(VARCHAR(10), GETDATE()-1,101) + '23:

  • DfltCustomization File is missing in Cisco ASA 5580

    I wanted to perform the customization of the SSL WebVPN page. But When I tried to create a new Customization object is is not happening as the DfltCustomization object is not available. We are having so many webvpn configuration and objects that i ca

  • Where is the search feature?

    isnt there search feature on ipods? its not on mine, when u scroll really fast the letter pops up for each song, but there is no search. so does it really exist, or is just something Steve Jobs said cuse he wanted to mess with people?