Mixing WAP321 & WAP121 Devices on Single Point Setup?

Hi,
Does anyone know if we can mix 2 WAP321 devices on a new Single Point Cluster, along with an additional WAP121 device?
Hopefully this is very easy.
Thanks!

Barry,
Using Single Point Setup with a mix of the WAP321 and WAP121 is not supported with the current firmware. It is possible that it will work depending on the configuration and it may be added as a feature in a future firmware.
- Marty

Similar Messages

  • WAP321 - No WDS and Single Point Setup

    Hi folks
    I bought 3 WAP321s with the intention of creating a fairly wide network in a large building where I can't easily add wiring.  Access was to be via a captive portal where I would create logins for all of the users.  However since I have bought the devices I discover that it isn't possible to use both WDS and clusters at the same time.  I have connected 2 devices by WDS by duplicating settings by hand in both but I have some questions that maybe some folks can answer?
    1. Do I have to copy both the captive portal design and the username and logins to each of the 3 devices for this to work? (I think that I do now)
    2. In the manual under the WDS discussion there is talk of both point to point and point to multipoint setups.  It seems to imply that with point to multipoint then there is a single WAP handling the client associations.  In that case does only one WAP handle the logins by captive portal?  I am trying to avoid having to duplicate the logins on all devices. 
    3. How do you decide in WDS if you are point to point or point to multipoint?  Is it just the number of connections that you have on the WDS setup page?
    An alternative if I am desperate is to use RADIUS but I am trying to avoid that
    Just for reference I have already read the manual for the WAP321 several times as well as watching the video on WDS setup
    Thanks
    Richard

    Hi Richard, thank you for using our forum, my name is Luis I am part of the Small business Support community.
    1 and 2. It isn't necessary to copy the same captive portal configuration for all the equipment, you should just configure the central WAP and the rest will receive the Captive portal.
    3. In the point-to-multipoint bridge mode, one WAP device acts as the common link between multiple access points. In your case if you are connecting two WAPs to one that is a multipoint bridge.
    I hope you find this answer useful
    Greetings,
    Luis Arias.
    Cisco Network Support Engineer.

  • WAP321 2 SSIDs not both showing Clustered in Single Point Setup

    I have 2 Cisco WAP321 with 2 SSIDs setup Single point using VLAN 1 and VLAN 2 using firmware version 1.0.5.3.  VLAN 1 is the management VLAN.  One WAP321 is connected to a SG200-8 version 1.0.8.3 on a trunked port 1UP,2T.  The SG200-8 is connected to a SG300-28 L3 switch version 1.3.7.18 on a trunk port 1UP,2T.   The other WAP321 is connected to a trunked port 1UP,2T on the SG300-28 switch.  Both SSIDs seem to work but the VLAN2 SSID does not show as clustered under single point Wireless Neighborhood.  Only VLAN1 shows clustered.  Do I have a setup issue? Is the Wireless Neighborhood not showing correct? What do you think is the problem why they are not showing clustered?  Both SSIDs work and connect to the internet.
    PS
    If it matters DHCP is from the SG300-28 in L3 mode which feeds a RV180 router from a 1UP port on the SG300-28.

    My name Eric Moyers. I am an Engineer in the Small Business Support Center.
    You do not have a setup issue. Clustering/Single Point Setup is based on the device and not on the SSID's. When looking at the Wireless Neighborhood within the Clustering section, you will only see the first SSID listed regardless of how many SSID's you have configured. 
    Now as far as the connection are concerned you said that your friends were having a hard time connecting. When they eventually connected were they going to the guest network? When you connect with your laptop, are you connecting to the same SSID or a different one?
    Eric Moyers
    .:|:.:|:. CISCO | Cisco Presales Technical Support | Wireless Subject Matter Expert
    Please rate helpful Posts and Let others know when your Question has been answered.

  • WAP321 Auto assign channels (Single Point)

    Hello there,
    I have 2x WAP321 (each about 50ft away from eachother) and have enabled the Signle Point Setup so I can see both there now).
    Now i also see the option of automatically assigning channels under channel management for the whole cluster (both xs points).
    This sounds like an interesting and cool idea but my question is, when it does change channel, wont that automatically disconnect all connected Wireless clients to the AP? Cause we have wireless speakers and other devices that should stay connected as long as possible.
    Does anyone know?

    Hi, My name is Eric Moyers. I am a Network Support Engineer in the Cisco Small Business Support Center. Thank you for using the Cisco Community Post Forums.
    You are correct. With Auto Channel any time that the WAP's change channels, there will be a disconnect of the devices when switching channels. I normally always recommend that the customer does not use auto channel
    Auto channel works best in a network that does not have a lot of signal noise around. In a crowd signal area if those signals are on auto and yours are on auto. your device would spend more time jumping around looking for a clear signal, than providing a signal for you to use.
    Thanks
    Eric Moyers    .:|:.:|:.
    Cisco Small Business US STAC Advanced Support Engineer
    CCNA, CCNA-Wireless
    866-606-1866
    Mon - Fri 09:00 - 18:00 (UTC - 05:00)
    *Please rate the Post so other will know when an answer has been found.

  • NI-DAQmx VisualStud​io C++ 6 Single point analog output

    Specs: NI-DAQmx 7, VisualStudio C++ 6.0,  PCI-6722,8channel AO
    We have a very simple application: set a voltage (actually 6 channels) and keep it until we want it changed again, perform the change very quickly in response to an image capturing algorithm. So I don't need any waveforms or buffering.
    In this forum post http://forums.ni.com/ni/board/message?board.id=231​&message.id=3283&query.id=18094 you talk about an AOOnePoint example, but I get an error that the NI-DAQ driver does not support my device.
    I may need to use NI-DAQmx, but how? I would like to use something like AO_VWrite(,,), maybe for 6 channels in one call. But I can't find it in NI-DAQmx. It seems I need to setup buffers and frequencies. I have a working sample, but it seems a slow and certainly overkill of this simple application:
    // Link with \DAQmx ANSI C Dev\lib\msvc\NIDAQmx.lib
    #include "NIDAQmx.h"
    double[2] data;
    int taskHandleAnalog;
    int written;
    void Init()
        DAQmxErrChk (DAQmxCreateTask("",&taskHandleAnalog));
        DAQmxErrChk (DAQmxCreateAOVoltageChan(taskHandleAnalog,"Device and Channel Info","",0,10,DAQmx_Val_Volts,NULL));
        DAQmxErrChk (DAQmxCfgSampClkTiming(taskHandleAnalog,"",1000,DA​Qmx_Val_Rising,DAQmx_Val_ContSamps,NUMBER_OF_AO_SA​AMPLES));
        DAQmxErrChk (DAQmxWriteAnalogF64(taskHandleAnalog,NUMBER_OF_AO​_SAAMPLES,0,1.0,DAQmx_Val_GroupByChannel,data,&wri​tten,NULL));
        DAQmxErrChk (DAQmxStartTask(taskHandleAnalog));
    void SetVoltage( double voltage )
        data[0] = voltage;
        data[1] = voltage;
        DAQmxStopTask(taskHandleAnalog);
        DAQmxErrChk (DAQmxWriteAnalogF64(taskHandleAnalog,NUMBER_OF_AO​_SAAMPLES,true,10.0,DAQmx_Val_GroupByChannel,data,​&written,NULL));

    Hi,
    It looks like you simply wants to output voltages on the analog output channels, but only wants one update at a time with no waveforms or buffering in DAQmx.
    As I'm sure you know there are really just 3 types of measurements.  Single Point, Finite, and Continuous.  Since you want a single value at a time it's just a Single Point operation.
    You can find DAQmx examples for single point operations in this path:
    C:\Program Files\National Instruments\NI-DAQ\Examples\DAQmx ANSI C\Analog Out\Generate Voltage\Volt Update
    Simply place the DAQmx Write Code within a loop and you will be updating one value at a time, but multiple times when "we want it changed again".
    Dennis Morini
    Field Sales Engineer
    National Instruments Denmark
    http://www.ni.com/ask

  • "Read Single Point" Keithley 2400 Problems

    Hello!
    I am recentely having some problems with the "Read Single Point Measurements" function in Labview 2012. I have already sucessfully used my Keithley 2400 in other programs to sweep the voltage, but now I am trying to use it also to read the current across my sample. 
    I wrote a very simple program, which resemble the one you can find among Labview examples (see 1st attachment). The only differences are a sweep-subVI and a "for" cycle. My problem occurs at the "Read" Keithley function. On the Keithley's screen I have the following errors:
    - 113 : undefined header;
    - 230: data corrupt or stale;
    - 420: query unterminated.
    While in the Block diagram, when the system gets to the "read" function, the error -1074000000 shows up.
    I have found a lot of posts on this topic, but unfortunately I could not find the any solution for me. I also tried the 2nd attached program, to check the comunication to the instrument, but errors still occur. In "Measurements and Automatic", it says that the instrument is working properly. 
    Do you have any ideas?
    Thanks  
    Attachments:
    Keithley 24XX Sweep and Acquire Measurements.vi ‏26 KB
    Basic Serial Write and Read (1).vi ‏26 KB

    The following video demonstrates how to check the firmware revision: http://www.keithley.nl/centralized_display?mn=2400&assetid=55934.
    In order to update the firmware you will be need to download a flash program and the firmware file. gAfter obtaining the Flash program and the Firmware file from Keithley Application support staff, unzip the three files in a folder of your choice and run the "setup.exe" program.  Follow the instructions to install the program.  When the installation is complete, launch the program from your Windows Start menu under Programs/Keithley Instruments. The Application support staff will also provide the file for the latest firmware revision. Put that file in a folder where you can find it and then run the Flash Wizard32 program. The program will autodetect the instrument and request to specify the firmware file.
    This link contains the flash program: http://www.keithley.com/base_download?dassetid=52609
     See attactment for the firmware revision.
    Attachments:
    2400c30.zip ‏358 KB

  • Single points of failure?

    So, we are looking into the xServe RAID, and I'd like some insight into making things as bulletproof as possible.
    Right now we plan to have:
    a load balancer and a failover load balancer (running on cheap BSD hardware, since hardware load balancers are so damned expensive) feeding into
    two application servers, which communicate with
    one back-end server, which serves as both a database server and an NFS server for the app servers
    And the volumes that will be NFS-mounted would be on our xServe RAID, which would be connected directly to the back-end server.
    The networking hardware would all be failover through multiple switches and cards and so forth.
    The idea here is to avoid as many single points of failure as possible. Unfortunately at the moment we don't have a DBA who is fluent in clustering, so we can't yet get rid of the back-end server as a single point of failure. (Which is also why I'm mounting the RAID on it and sharing via NFS... if the database goes down, it won't matter that the file service is down too.) However, in the current setup, there's one other failure point: the RAID controllers on the xServe RAID.
    Performance is less important to us on this than reliability is. We can't afford two RAID units at the moment, but we can afford one full of 500 gig drives, and we really only need about 4 TB of storage right now, so I was thinking of setting up drive 0 on controller 0 and drive 0 on controller 1 as a software RAID mirror, and the same with drive 1, etc. As far as I understand it, this eliminates the RAID controllers as a single point of failure, and as far as I know they are at least supposedly the only single point of failure in the xServe RAID system. (I could also do RAID 10 that way, but due to the way we store files, that wouldn't buy us anything except added complexity.)
    And later on, down the road, when we have someone good enough to figure out how to cluster the database, if I understand correctly, we can spend the money get a fibre switch or hub or whatever they call it and mount the RAID on the two (application server) systems that actually use it, thus cutting out the middle man NFS service. (I am under the impression that this sort of volume-sharing is possible via FC... is that correct?)
    Comments? Suggestions? Corrections to my misapprehentions?
    --Adam Lang

    Camelot wrote:
    A couple of points.
    was thinking of setting up drive 0 on controller 0 and drive 0 on controller 1 as a software RAID mirror, and the same with drive 1, etc.
    Really? Assuming you're using fourteen 500GB drives this will give you seven volumes mounted on the server, each a 500GB mirror split on the two controllers. That's fine from a redundancy standpoint, but it ***** from the standpoint of managing seven direct mountpoints on the server, as well as seven NFS shares, and 14 NFS mount points on the clients. Not to mention file allocations between the volumes, etc.
    If your application is such that it's easy to dictate which volume any particular file should be on and you don't mind managing all those volumes, go ahead, otherwise consider creating two RAID 5 volumes, one on each controller, using RAID 1 to mirror them on the back-end server and exporting a single NFS share to the clients/front-end servers.
    Quite simple, actually. But admittedly, two RAID 5s RAID-1-ed together would be much more efficient, space-wise.
    if I understand correctly, we can spend the money get a fibre switch or hub or whatever they call it and mount the RAID on the two (application server) systems that actually use it
    Yes, although you'll need another intermediate server as the metadata controller to arbitrate connections from the two machines. It becomes an expensive option, but your performance will increase, as will the ease with which you can expand your storage network (adding more storage as well as more front-end clients).
    But then that means that the metadata controller is a single point of failure...?
    --Adam Lang

  • Linux cluster, no single point of failure

    I'm having difficulty setting up a Business Objects cluster in linux with no single point of failure.  Following the instructions for custom install I am ending up connecting to the CMS server on the other server and no CMS running on the server i'm doing the install on. Which is a cluster, however we only have CMS running on one server in this scenario and we can't have a single point of failure.  Could someone explain how to setup a 2 server clustered solution on linux that doesn't have a single point of failure.

    not working, I can see my other node listed in the config, but the information for the servers state that the SIA is available, I've checked network/port connectivity between the boxes and SIA is running and available for each box.
    Via the instructions for installing on a system with windows capabilities I read about a step to connect to an existing CMS.
    http://wiki.sdn.sap.com/wiki/download/attachments/154828917/Opiton1_add_cms3.jpg
    http://wiki.sdn.sap.com/wiki/display/BOBJ/Appendix1-Deployment-howtoaddanotherCMS-Multipleenvironments
    via the linux install.sh script, no matter what I do I'm not coming across any way that allows me to reach that step.

  • Acquire single point 12 bit data @ 200Khz using PXIe 6535 DIO RT

    I want to acquire single point 12 bit data @ 200Khz using PXIe 6535 DIO, PXIe 1072 chasis and 8820 controller in RT. Problem is I am unable to acquire data as triggered input. Loop execution time takes ~10us (measured using rt tick count). Thus It misses the samples. Am I missing something? What are the proper ways to acquire digital data in RT?
    Also I am wondering whether I can use the SMB connector of 8820 controller as my acquision trigger input pulse. I am completely new to RT. Any help will be appriciated.
    Thank you.

    Hi jtele1,
    To make sure that the data gets written in the correctly order I would recommend monitoring the Time Out of the write. If a time out occurs you could stop writing all FIFOs and then start when all the Time Outs are no longer there. Another option is to look at your host side and determine if you can read larger chunks of data at a time and allow the host side to deal with processing the data. An additional option would be to look into high throughput streaming for FlexRIO. In this setup you will be writing the data directly to disk on your host side and then you could process the data at a later time. I have linked an example below, this example was giving me trouble so please let me know if you have trouble loading this example. Depending on your situation these may not all be acceptable options but you will need to ensure that you are not filling any of your FIFOs. Lastly, from what I can tell you are using a Windows OS as your host and in that situation you have no way of controlling when your LabVIEW application gets processor time. If you were to switch to a Real Time controller you would be able to ensure when certain tasks are run and add priority to tasks. Please let me know if you have further questions. 
    High Throughput Streaming
    https://decibel.ni.com/content/docs/DOC-26619
    Patrick H | National Instruments | Software Engineer

  • Cluster Single Point of Failure

              It appears from the documentation that in order to have a cluster that
              you need to setup a proxy server which act as the director to
              all the other servers in the cluster.
              What happens if this proxy server goes down then it doesn't matter
              how many servers you have in the cluster.....
              Doesn't this represent a single point of failure ?
              Thanks in advance!
              

    George,
              You may have multiple proxies, avoiding SPF. They are "stateless", so it
              doesn't matter what request goes to which, so you can use hardware load
              balancers in front of the proxies. Most hardware load balances also support
              failover, avoiding SPF there as well.
              In 6.0, the proxy is not required, but unless you have reasonably good
              hardware load balancers in front, you should still use one or more proxies.
              One other thing to consider is distribution of work. The proxy (such as
              Apache) can act as the web server for static content and is much more
              efficient in terms of execution and in terms of dollars than Weblogic for
              such simple tasks.
              Peace,
              Cameron Purdy
              Tangosol, Inc.
              http://www.tangosol.com
              +1.617.623.5782
              WebLogic Consulting Available
              "George M. Pieri" <[email protected]> wrote in message
              news:[email protected]..
              >
              > It appears from the documentation that in order to have a cluster that
              > you need to setup a proxy server which act as the director to
              > all the other servers in the cluster.
              >
              > What happens if this proxy server goes down then it doesn't matter
              > how many servers you have in the cluster.....
              >
              > Doesn't this represent a single point of failure ?
              >
              >
              > Thanks in advance!
              >
              >
              >
              >
              >
              

  • XNET CAN (frame in)single point issue

    Hi guys,
    I have a problem reading a frame in a single point session. I have this issue now in two different (labview)vi's. In the first a device sends a single frame and I catch it in labview. In the second I send a single point frame from the same vi through another CAN tranceiver and catch this frame in the same vi.
    Sometimes the payload get catched and sometimes(like 5 executions) it's like nothing is received? How can I check raw frame data to know my payload is received?

    You are actually not doing single-point, instead, you are doing Stream Input. This will read into a queue of frames.
    In your while loop, you are doing a Frame CAN read w/o a timeout and a quantity of -1. This means, "return all frames that are currently available". Note, if there are no frames available, this will return an empty array.
    Here is where it gets tricky and you may need to know more about LabVIEW. You have an empty array, and you are then passing that into "index array". If you index an ampty array, you will get get a valid element (since an element cannot be empty) that contains the values of all zeros. This means that the timestamp will have a value of 0 and the payload will be an empty array.
    In the next frame, you are just checking for new timestamp to be different from the old timestamp. If the old timestamp was Feb 8th, 2011 @ 07:03 and the new timestamp is '0', that is indeed different and you will capture that as a frame detection.
    The simple fix would probably be to make frame detection only trigger on "(old != new) && (new != 0)". Note you need to also skip "old = new" in the last frame if you did NOT detect a frame.
    Other possible fixes:
    1. Read for 1 frame with a timeout. This will pause the VI until a frame is actually read.
    2. Since this is a queue (and not single-point), you can read and "frame detect" would just be if the array is not empty. With queues, old data is not repeated, so there would be no frames in this case. This dramatically simplifies your VI.

  • Problem with Set/Get volume of input device with single channel

    from Symadept <[email protected]>
    to Cocoa Developers <[email protected]>,
    coreaudio-api <[email protected]>
    date Thu, Dec 10, 2009 at 2:45 PM
    subject Problem with Set/Get volume of input device with single channel
    mailed-by gmail.com
    hide details 2:45 PM (2 hours ago)
    Hi,
    I am trying to Set/Get Volume level of Input device which has only single channel but no master channel, then it fails to retrieve the kAudioDevicePropertyPreferredChannelsForStereo and intermittently kAudioDevicePropertyVolumeScalar for each channel. But this works well for Output device.
    So is there any difference in setting/getting the volume of input channels?
    I am pasting the downloadable link to sample.
    http://www.4shared.com/file/169494513/f53ed27/VolumeManagerTest.html
    Thanks in advance.
    Regards
    Mustafa
    Tags: MacOSX, CoreAudio, Objective C.

    That works but the the game will not be in full screen, it will have an empty strip at the bottom.
    I actually found out what's the problem. I traced the stageWidth and stageHeight during resizing event. I found out that when it first resized, the stage width and height were the size with the notification bar. So when I pass the stage into startling, myStarling = new Starling(Game,stage), the stage is in the wrong size. For some reason, I can only get the correct stage width and height after the third resizing event.
    So now I need to restart Starling everytime a resizing event happened. It gives me the right result but I am not sure it is a good idea to do that.
    And thanks a lot for your time kglad~I really appriciate your help.

  • Why can't we have a single point of contact who de...

    Three weeks ago our house was hit by lightning and our broadband connection went on the blitz (a Linnit technical term).
    The telephone stopped working. I did an on-line check and the connection registered a fault. The on-line system logged the fault with the teachnical team. So far so good...
    I received a call from the tech team advising an engineer was coming out to us, if the fault was with our equipment we would be charged. That's fair. Engineer called. My phones were fine, BUT the BT router was where the fault lay said the engineer. We would need to raise another fault report because he only dealt with telephone AND as he was a subcontractor he would bill for the work... He disconnected the router so the phone would work and left.
    I work virtually, which means that I can work from my home, so I need the internet even more than my family want the telephone. I plugged the internet back in so that I could continue to work and called BT again from my mobile. Speaking to a very polite guy in Delhi I was asked to describe my phone socket, unplug the router from the office, carry it downstairs to the kitchen where the main socket is, plug the router in there, reconnect, try again, all sorts of stuff before finally being advised that it was probably just the 'microfilter' and that as they were very inexpensive it might be faster for me to go out and buy one and plug it in myself rather than have another engineer come out to us.
    So I did just that. In fact, as the microfilters are less than a fiver, I got two... brought them home and plugged one in... didn't work.
    Called Delhi again. Spoke to someone else who was, again, very polite. They tried to get me to unplug and plug things in and out again, but I politely declined this time explaining that now the poor internet connection that we did have was running so slowly I am having to commute in to work over Christmas. He sympathised and told us that he would escalate the issue. That was before Christmas. Since then I received a text on my phone on Christmas Day telling me they couldn't reach me!!! 
    Today I called again to BEG someone to please come out and fix things for us. We aren't technical. We cannot act as pseudo engineers. We pay BT one bill each quarter for a service. Why on earth can't BT provide me with a single point of contact when I have an issue. And if that point of contact could understand me and explain things to me in words and phrases that I understand that would be perfect!
    Last year I cancelled three mobile contracts that we'd had since the early 90's with O2 because they were so unhelpful.
    BT aren't the cheapest broadband provider but we've stayed with them out of 20+ years loyalty and the understanding that we had a one-stop-shop. Now, it looks as though I'll be shopping around for another domestic broadband provider for 2012.

    Thank you for being so helpful and constructive.
    I tried to look at the ASDL settings, john46 but it's asking me for my HomeHub password... the only password I have is for our wireless network and that one doesn't work. 
    I can't test the phone line right now because I'll have to disconnect the internet and I'm currently working on another computer whilst chatting on this one with you. However I will do that later. I'll also look at the RogerB link you provided. 
    Truth is, we're pensioners who use the internet but we havent a grain of technical understanding between us. We're old fashioned enough to admit that we just want someone who knows what he's doing to come here and fix it for us. It's already cost us £130 for an engineer to come out from OpenReach to tell us the phone line is OK and it's the router causing the problem. Best case scenario is that another BT engineer who knows about broadband comes out and does it because the last BT person that I spoke to in Delhi did actually confirm that there is a fault on the BT side. I'm getting so frustrated right now I'll probably call out an independant I find in Yellow Pages and get charged an arm and a leg again and I'll then cancel with BT in a fit of pique.

  • Pl/sql block reading reading table data from single point in time

    I am trying to figure out whether several cursors within a PL/SQL block are executed from within a Single Point In Time, and thus do not see any updates to tables made by other processes or procedures running at the same time.
    The reason I am asking is since I have a block of code making some data extraction, with some initial Sanity Checks before the code executes. However, if some other procedure would be modifying the data in between, then the Sanity Check is invalid. So I am basically trying to figure out if there is some read consistency within a PL/SQL, preventing updates from other processes to be seen.
    Anyone having an idea?.
    BR,
    Cenk

    "Transaction-Level Read Consistency
    Oracle also offers the option of enforcing transaction-level read consistency. When a transaction runs in serializable mode, all data accesses reflect the state of the database as of the time the transaction began. *This means that the data seen by all queries within the same transaction is consistent with respect to a single point in time, except that queries made by a serializable transaction do see changes made by the transaction itself*. Transaction-level read consistency produces repeatable reads and does not expose a query to phantoms."
    http://www.oracle.com/pls/db102/search?remark=quick_search&word=read+consistency&tab_id=&format=ranked

  • Every device (iphone4, iphone4s, ipad2) I try to hook up to iTunes gives me a message "this device cannot connect because the apple mobile device service is not setup" does anyone have ideas as to why it keeps popping up? It just started doing this.

    Every device (iphone4, iphone4s, ipad2) I try to hook up to iTunes gives me a message "this device cannot connect because the apple mobile device service is not setup" does anyone have ideas as to why it keeps popping up? It just started doing this.

    I'd start with the following document with that one:
    iPhone, iPad, iPod touch: How to restart the Apple Mobile Device Service (AMDS) on Windows

Maybe you are looking for