Modelsupport2.dll changes don't take affect

Running TestStand 4.0 and LabWindows/CVI 9.0.1.
Followed instructions per http://digital.ni.com/public.nsf/allkb/A6D0EF1F4FE5EC94862570AE000CE374 to change my test socket numbers to be non zero based for batch model.  Also modified paralleluutdlg.c to increase the MAX_NUM_TEST_SOCKETS_VISIBLE 6 (used to be 5).
The modelsupport2.dll compiled successfully, but the changes do not occur when I run my sequence file using the batch model; i.e., the test sockets still start from 0 instead of 1 and the number of visible sockets is 5 and not 6.
I checked the configured search directories and the user components directory (containing my modified files) is ahead of the default NI components directory as desired.
Am I missing a required step here?
Thanks!
Solved!
Go to Solution.

Hi George,
The KnowledgeBase article you are referring to is for the parallel model, not the batch model. However, if you open the batchuutdlg.c and search for the same line of test as described in the KB and add "+1" to it, it should work. I have confirmed that it works on my end. Just to make sure this is clear, this only changes the dialog box and will not change the numbering in the process model. Changing that numbering requires a much more extensive effort.
Regarding the MAX_NUM_TEST_SOCKETS_VISIBLE 6 change, I have also done this and it does show 6 visible batches in the dialog box. Please keep in mind that you need to just replace the number without changing the spacing on the line. You will also need to go into Configure->Model Options and change the Number of Test Sockets to 6 to ensure that you see the 6 visible batches. Changing this will cause the window to expand over the "Go" and "Stop" buttons so there will have to be more extensive changes to move those buttons down. I hope this helps address your question!
Regards,
Jackie
DAQ Product Marketing Engineer
National Instruments

Similar Messages

  • Theme changes don´t take effect

    Hi,
    I recently wondered why the theme of my LXDE installations doesn´t really look good:
    http://upload.worldofplayers.de/files10/lxde.jpg
    Particulary, Midori is rather ugly:
    However, other screenshots of LXDE proove that it can look much better:
    https://wiki.installgentoo.com/images/1 … t_LXDE.png
    Sometimes Midori looks really nice, for instance in this screenshot:
    http://midori-browser.org/images/screen … ressed.png
    In order to change the appearance, I´ve already installed gtk-engines. Now I have several themes like Clearlooks at choice in LXAppearance. Unfortunately, clicking the apply-button doesn´t affect the appearance, neither the preview window.
    What´s going wrong?
    Please excuse linguistic mistakes, i´m from Germany.
    Thanks!
    superuser
    Last edited by superuser (2015-04-13 19:52:05)

    .xinitrc:
    exex startlxde
    lightdm.conf (I removed the unused lines):
    [LightDM]
    minimum-vt=1
    run-directory=/run/lightdm
    greeter-session = lightdm-gtk3-greeter
    display-setup-script = /usr/bin/lightdmxrandr
    [SeatDefaults]
    session-wrapper=/etc/lightdm/Xsession
    display-setup-script =/usr/bin/lightdmxrandr
    users.conf:
    [UserList]
    minimum-uid=1000
    hidden-users=nobody nobody4 noaccess
    hidden-shells=/bin/false /usr/bin/nologin
    Besides, I forgot to mention that I´m using a virtual machine, namely VMWare Player.
    As you may have seen, the font is rather hard to read in Midori.
    What is also remarkable is that the system reacts often very sluggishly, especially when clicking the LXDE button or marking text.
    Last edited by superuser (2015-04-13 20:47:44)

  • Business Event Subscription Changes don't take immediate effect

    Hi, it seems that whenever I make changes to my business event subscriptions the changes only take effect the next day. (Almost like there is some concurrent request running at night, or something bounced to make the changes) Does anybody know what needs to be bounced, or what concurrent request needs to be run to make the changes take effect.
    I'm using Oracle Applications: 12.0.4 under the "Workflow Administrator" responsibility.
    Any help appreciated.
    Regards,
    Marinus Snyman

    Try restarting the Workflow Background Manager.

  • Changes don't take

    When I make changes to a raw file's settings in LR, nothing gets changed on the file as seen in Bridge or Camera Raw. What am I doing wrong?
    (I have the automatically export XMP data box checked. But that is not relevant to settings anyway, is it?)
    I am using LR 1.3 and PS CS2 w/ Camera Raw 3.7, on a Mac G4, OSX 10.4.6.
    Thanks,
    Dean

    Lee,
    Okay, I am confused. I thought maybe that box applied to metadata like keywords, copyright, etc., but not image settings. (The "sync" buttons in the interface seem to differentiate between meatdata and settings.)
    In any event, the box IS checked.
    To be honest, I have never understood why anyone would NOT want all changes in either software to automatically transfer. That has always been a mystery to me. But in any event, I want it to.
    Dean

  • Screensaver changes don't take effect

    I went into System Preferences/Desktop&ScreenSaver/Screensaver/Options to change a couple of things, and then I went into Hot Corners to add hot corners, but after I exited the Screensaver screen, none of my changes took effect. There doesn't seem to be any OK or Apply button to start any of the changes... How can I get my changes to work?

    .xinitrc:
    exex startlxde
    lightdm.conf (I removed the unused lines):
    [LightDM]
    minimum-vt=1
    run-directory=/run/lightdm
    greeter-session = lightdm-gtk3-greeter
    display-setup-script = /usr/bin/lightdmxrandr
    [SeatDefaults]
    session-wrapper=/etc/lightdm/Xsession
    display-setup-script =/usr/bin/lightdmxrandr
    users.conf:
    [UserList]
    minimum-uid=1000
    hidden-users=nobody nobody4 noaccess
    hidden-shells=/bin/false /usr/bin/nologin
    Besides, I forgot to mention that I´m using a virtual machine, namely VMWare Player.
    As you may have seen, the font is rather hard to read in Midori.
    What is also remarkable is that the system reacts often very sluggishly, especially when clicking the LXDE button or marking text.
    Last edited by superuser (2015-04-13 20:47:44)

  • Batch changes don't function. Apt 3.2. From simple commands like "rotate clockwise" to "lift and stamp" the command only affects to the last image in the group selected. Similar problems? Solutions?

    Batch changes don't function. From simple commands like "rotate clockwise" to "lift and stamp" the command only affects to the last image in the group selected. Similar problems? Solutions? Suggestions? Thanks, Bruce

    Glad it helped. Everyone has been bitten by this at one time or another. Fortunately you only get bit once
    Well if you haven't already read it two or three times the User manual is really very good. Apple really did a nice job with it. The on-line version is nice because it is searchable.
    After that the Apple Pro Training Series book Aperture 3 is very useful. Its basically split into three parts. The library, adjustments and sharing. In addition if you get all the way through it you can take the Certification test and become, well certified.
    Rwboyer who posts here on and off has a good site and a couple of ebooks that I found useful.
    good luck

  • 10.6.4 AFP - ACLs - Workgroup Manager :: changes need reboot to take affect

    hello community
    still new to OSX Server I am a bit confused regarding changes made to
    AFP - ACLs - Workgroup Manager
    do changes really need a server reboot to take affect?
    scenario:
    *Workgroup Manager ...*
    User1
    User2
    User3
    GroupFolder1 :: Members -> GroupSubFolder1.1 + GroupSubFolder1.2
    GroupSubFolder1.1 :: Members -> User1
    GroupSubFolder1.2 :: Members -> User2
    *AFP shares & folders with ACLs ...*
    Folder1 :: ACL read for GroupFolder1
    SubFolder1.1 :: ACL read for GroupSubFolder1.1
    SubFolder1.2 :: ACL read for GroupSubFolder1.2
    (SubFolder1.1 + SubFolder1.2 are nested into Folder1
    to make it clear)
    this workz perfect!
    if I now switch in Workgroup Manager the memberships to eg.
    *Workgroup Manager ...*
    User1
    User2
    User3
    GroupFolder1 :: Members -> GroupSubFolder1.1 + GroupSubFolder1.2
    GroupSubFolder1.1 :: Members -> User2 + User3
    GroupSubFolder1.2 :: Members -> User1
    this will only take effect when rebooting the server.
    I tried to ...
    start/stop AFP
    restart ldap, by deselectingsaving/selectingsaving the SSL cert for OpenDirectoryService
    restart the clients
    nothing helped but restarting the MacMiniServer
    server and all clients are running 10.6.4
    cannot be that one has to reboot the whole machine to make AFP - ACLs - Workgroup Manager changes take effect?
    ok I am running a rather small setup, but what if ya want to integrate a new user into a bigger environment? this will lead to a disconnect for all users connected or an "over-night-wait-time" for the new user, whilest scheduleing a reboot somewhere in the night? but even then what if people are connected in different timezones overseas via vpn?
    where is the hook to make the settings take effect immediately after saving the changes?
    any other info I can provide to reproduce/solve the issue?
    rgds,
    g.
    Message was edited:
    tried to correct my spelling, please bare with me I am no english native

    Well that suggestion from the site referenced above about tearing the OD down, deleting the slapd.conf files and bringing it back up didn't work. 10.5 servers still see changes in OD as they happen and 10.6 servers don't see the change until around 10 minutes later.
    Anyone run across this and fixed it?

  • I changed my AppleID password this morning and now I can't load iTunes gift card numbers to download music. The system keeps taking me to the account screen to verify payment info. When I click on DONE, it takes me back to the password screen.

    I changed my AppleID password this morning and now I can't load gift card numbers into iTunes to download music. The system takes me to the account settings screen to verify those and when I click on DONE, it takes me back to the password screen and I start over. This becomes an endless loop. What now.

    Greetings Ron,
    After reviewing your post, I have located an article that can help with gift card issues. It contains a number of troubleshooting steps and helpful advice for the issue you are experiencing:
    If you can't redeem your iTunes Gift Card or code
    Contact iTunes Store Support
    If the code is completely scratched off or you still can't redeem your gift card, contact iTunes Support:
    Go to the iTunes Store support page and choose your country.
    From the menu on the left, choose Contact Support.
    Click Contact iTunes Store Support.
    Follow the instructions.
    iTunes Store Support might ask you to send these things:
    Image of the full front and back of your gift card
    Sales receipt showing when your card was purchased
    Serial number from your gift card
    Thank you for contributing to Apple Support Communities.
    Best,
    Bobby_D

  • When making changes to the I/O buffer size( motu-pci 424) it takes an abnormal length of time for the changes to take affect any ideas?

    when making changes to the I/O buffer size( motu-pci 424) it takes an abnormal length of time for the changes to take affect any ideas?

    A fully loaded one( keep in mind I have had fully loaded projects in the past, and it did not take this long) this was noticed after installing LP8, also major latencey even at 64 buffer size

  • Changes in iAS6.5's web.xml don't take effect

    After the cust deployed his application he modified some parameters in
    the web.xml file of his application. He then restarted the application
    server after but the changes didn't take effect. Is this the
    expected behavior as they would need to custom web.xml
    and expand the war file before deploying to see the changes reflected in the
    pages because changing those after deployment doesn't work.
    Thanks for your help,
    Gaetan

    In response to author 97:
    are made in the registry during the deployment processI tried redeploying a sample web application using <init-param> and cannot find a trace of the newly referenced variable.
    Could you indicate in which regitry path should it be found?
    thanks,
    Gaetan

  • TestStand LabVIEW OI and modelsupport2.dll

    I'm trying to understand how to do some customization of the LabVIEW version of the TestStand (3.5) Operator Interface.  I need the default OI to change in several areas.  One in particular is that a teamate company (dictating the look and feel) wants us to have a Data Entry dialog.  They say that it's part of the TestStand Sequential Process Model and it's contained in ModelSupport2.dll, and that it contains its own GUI that is used by the process models.
    I hope to develop tests in LV8.  As a first step, I'm trying to understand how (and when) to call the functions within the modelsupport2.dll.  I there any documentation on the functions within (other than the .h)?  Can someone walk me through an example where a sequence file (or is the call made from LabVIEW?) displays some dialog that is supposedly in modelsupport2.dll?

    There's several dialogs in modelsupport2. There's the serial number dialogs for the sequential model, parallel model, and batch model. The only other dialogs are for the report file options and model options. The last two are what you get when select Configure>Report Options and Configure Model Options. The serial number dialogs are called in the process model like the other company said and I don't know of any test sequence or OI that would call them directly. If you want to override them and use your own serial number dialog, then you can put own callback in a sequence.

  • How to revert the changes done  in  an  ABAP query

    hi experts,
    how to revert the changes done  in  an  ABAP query.
    I renamed a field in ABAP Query in development system, but the output list now has overlapping fields.
    the renamed field is getting overlaped with other fields, also one more field has overlapped.
    now the problem is how to get back to the previous version of the query so that the overlapping fields can be corrected.
    renaming one field has led to the problem of overlapping fields in the output.
    the sequence of the fields has also been affected.
    Please help

    Hi,
    Goto Utilities-> versions-> version management.
    It will show you list of previous TR's. Just click on the version which you want to retrieve and click on Retrieve button on the top.
    Your program will be retrieved to your previous version before change.
    Hope this will help.
    Regards,
    Aravind.

  • Using ModelSupport2.dll in LabView without TestStand

    I would like to use the ModelSupport2.dll purely in a LabVIEW environment as either by a "Call Library Function Node" or "Active X" or ".NET" without using TestStand.
    In particular I would utilize the the "DisplayPassBanner" and "DisplayFailBanner" functions. I want the banner pop-up's so I can provide a consistency between applications that don't use TestStand and those that do.
    The DLL call requires a numeric input "context" which I am not sure what it needs for a reference number.
    In teststand it is passed an "Object", "CVI Active X Automation Handle", "By Value" from the "ThisContext"
    How replicate this or create equivalent in LabVIEW
    Any suggestions appreciated
    A

    A,
    if you are looking into the sources of ModelSupport2.dll (the sources are included as LabWindows/CVI project and the needed C files), you will see that the display banner functions do access the object referenced by the parameter 'context'. The context is a reference to the dataset of a running TestStand execution when called from the TestStand process model.
    So it will not be possible to use those functions if you are not going to use TestStand/running an actual sequence.
    There are, however, two ways you can go for:
    a) Design a LV VI dialog such way that it looks like one of the banner and call it as a subVI.
    b) Use the LabWindows/CVI sources of ModelSupport2.dll to copy the banner dialogs into a new CVI project (from modelpanels.uir) and create similar functions into a custom written dll which do not require the ActiveX handle 'context' to be passed.....
    hope this helps,
    Norbert
    CEO: What exactly is stopping us from doing this?
    Expert: Geometry
    Marketing Manager: Just ignore it.

  • Equipment changes in ECC not affecting in CRM

    Hi,
    Equipments from ECC are loaded in CRM. Then any changes done for equipment in ECC, not affected those changes in CRM. What needs to check for this to happen.
    rgds,
    balu

    Hi,
    Thanks for the quick reply...
    1. In CRM,
    SPRO->CRM->Master Data->Installed Base->Replication of Technical Objects from SAP ERP->Define Default Settings for Replication of Equipment
    i hv activated Delta Load check box.
    2. No changes are affecting for all equipments.
    3. In table TBE31, following data is maintained:
    EVENT : 00001270
    APPLK : BC_MID
    FUNCT: CRS_MATERIALRT_COLLECT_DATA
    EVENT PM000020
    APPLK BC-MID
    FUNCT EQUIPMENT_COLLECT_DATA
    In table CRMRFCPAR, field DISCARDDAT has not checked.
    rgds,
    balu

  • Switching modelsupport2.dll

    We are using sequences running with batchmodel with a modified modelsupport.dll i teststand user directory, because we usually need an additional entry  an additional partnumber for  each UUT and overriding pre UUT callback doesn't work well in batchmodel.  
    Now we have one type of UUT without that additional partnumber. Is it possible to make the sequence for that UUT using the "standart" modelsupport2.dll in installation path even if there is the modified modelsupport2.dll in teststand user ? 

    Hi mkossmann,
    as far as I know modelsupport.dll is part of the process model. Thus I guess you have also 2 process models. In the following link you'll find an instruction to change the process model:
    How Do I Specify a Particular Process Model for a Specific Sequence File?
    http://digital.ni.com/public.nsf/allkb/CEDEDEB004083D6F862572B400779E46?OpenDocument
    I hope this helps.
    Kind regards
    Heinz

Maybe you are looking for