Monitoring Multiple RFCs with CCMS

Hi,
I have created a Z data collection method as per NOTE 1069130,mapped it to the standard MTE Class "
"Availability_RFC_Destinations" But i dont see the data in RZ20 monitor  Plese help me with this

Hello Chris,
just played around on my test system...
> Also MTE_CLASS, which is left blank.
If MTE_CLASS is used but left blank the MTE will be created with an MTE class "Availability_RFC_Destinations_MA_Class" (I assume this is the case in your system).
If the MTE_CLASS parameter does not exist in the method definition, the data collector will use "<name of data collection method>_MA_Class" as MTE class.
> I tried removing MTE_CLASS
That's a good idea but at first you will have to delete the MTEs directly from rz20 using "Option 4" when the popup regarding how to delete the MTE comes up. This way the information about the MTE and the assigned MTE class is deleted from the monitoring shared memory. After you have deleted the MTEs you can reset the monitoring segment into warm-up status again (now using the data collection methods without MTE_CLASS parameter). This way the MTEs should be created using their individual MTE class.
Regards, Michael

Similar Messages

  • Monitoring SMD Agent with CCMS

    Hi gurues, I need to know if there is any way to monitor SMD Agent installed in an application server via CCMS CEN system on a Solution Manager.
    Right now we have CEN Monitoring define on Solution Manager, and several SMD Agents over the whole landscape, and it is critical for us to get alerted when this SMD goes down, so we are thinking about monitoring through Solutin Manager, isthat possible or we must do it in another way?
    Regards
    Gustavo

    It's so typical SAP; I was looking for exactly the same question. SAP changed from 7.1 the OSCOL to run by the host agent instance and will not install the OSCOL to the SAP instance. You also will not be able to download OSCOL separatly.
    But OSCOL is needed to monitor processes on host side. If the host agent don't starts also the OSCOL will not start (on LINUX side) and so you are not be able to monitor the SMD process.
    The only chance is to start the SMD via init script.
    A better way would be to implement a GRMG availability monitoring; this can be implemented in the CEN system independent from the monitored host. In the first solution the host has to be create itself the basis to monitor itself... that's nonsense.
    I absolutly don't understand why SAP always and everywhere ignore his own design concept and reinvent the wheel. It would be so easy to design and implement the availability moniroring on SAP development side but they don't have a focus on that. It is the same with SAP router connection via host agent to the CEN system. It was implemented as very last feature after a lot of disgruntled customers (administrators).

  • How to block the multiple logons with NWBC?

    Hello,
    With Sapgui we have the possibility to prevent the multiple dialog logon by profile parameters (login/disable_multi_gui_login).
    How to prevent the multiple dialog logon using NWBC to the same system?
    Best regards
    Frédéric Blaise
    e-Kenz S.A.
    Luxembourg

    Hello,
    I opened a ticket at Sap but unfortunately they do not have a solution even if the problem is known.
    "Unfortunately, due the HTTP protocol nature, is not possible to force a single logon via web browser. The profile parameter login/disable_multi_gui_login is solely valid for SAPGUI logons."
    "Since this case is known since the Web Application Server was created, I am pretty convinced that SAP knows about the fact that multiple logons cannot be blocked (you can only give a warning for the user)."
    Since we monitor multiple connections with the SM04 transaction and notify customers that they may be controlled by Sap.
    Best regards
    Frédéric

  • RFC monitor with CCMS

    Hello,
    I'm implementing RFC monitor with CCMS and I have a problem.
    I was able to implement the method with an auto-reaction method of send mail.
    It is working fine but it doesn't repeat the alert!  Let's say, imagine that the RFC isn't working since 3am... we are now at 13pm and the alert is not triggered anymore. In fact, in RZ20 I just see 1 Alert triggered at 3am.
    Is there any way to set this alert to trigger every period of time?
    thanks.
    regards,
    Filipe Vasconcelos

    Hello,
    first it would be good to clarify which monitor are you implementing - there are multiple RFC monitors - for example:
    Availability and Performance Overview Monitor :
    http://help.sap.com/saphelp_nw70/Helpdata/en/ae/cd823bd26a5c42e10000000a114084/frameset.htm
    Transactional RFC and Queued RFC Monitor
    http://help.sap.com/saphelp_nw70/Helpdata/en/8b/ceea3b31aac554e10000000a114084/frameset.htm
    Best to type the name of monitor as displayed in RZ20.
    Based on the type of monitor you might find the answer here:
    http://help.sap.com/saphelp_nw70/Helpdata/en/f6/c55c3bab977239e10000000a114084/frameset.htm
    (for example for status monitor you can set option "When should a message trigger an alert?" to "Always (at every message)")
    Anyway I am afraid that in case you are using performance monitor there is not much you can do. Possibility can be to check if data collection method (for example function) has parameter that can do this (but I am skeptical about this) - if not then you would have to adjust data collection method or implement the monitoring in another way.
    Possibility can be to use some kind of "switch". You can activate option "Display All-Clears in Alert Browser" - this will generate green alerts. Then you can program your own autoreaction method that will perform the "switch operation" (simple insert/update/delete into some Z-table you will create - based on status of alert - red/yellow/green.) Then you can have batch job running another Z-program that is reading this value and constantly reminding use via email.
    If you program this in a good way (abstract autoreaction method) - you can reuse this solution for other monitors as well and easily buid you own email notification functionality.
    I hope it helps.
    Best regards.

  • File to RFC with multiple records using BPM Scenario Error...!!!

    Hello Guru's,
      I have done the File to RFC with multiple records using BPM scenario as per the Materiel available in the sdn.sap. This involves BAPI (BAPI_MATERIEL_AVAILABILITY). I have done exactly the same what is their in the materiel. SXI_CACHE is also giving return value " 0 ". File is getting deleted from the source directory, but no file in target directory. SXMB_MONI is also showing no error (black Flag). BPM is also error free. Checked the interfaces also.
    Can any one tell me what mistake would i have done.
    Thanks in advance.

    Hi,
    There is one similar discussion I found,
    FTP TO RFC using BPM
    Thanks
    Swarup

  • Adapter Monitoring with CCMS

    Hi,
    is there anybody who already set up an adapter monitoring  with CCMS using the alert framework of Runtime Workbench ?
    Background:
    When using the existing MTE's in CCMS (J2EE Monitor Templates - All Systems - <SID> - J2EE Applications - SAP XI Adapter Engine) only rare monitoring information related to XI messages are posted.
    What I would like to see are information about the adapters provided in the logfiles of each adapter.
    For example as soon there's a permission problem for a directory in File Adapter an alert in CCMS should be raised.
    I already checked SAP notes 870232, 913858 and 824039.
    Any feedback appreciated.
    Cheers,
      Juergen

    Hi,
      You can configure the CCMS as per the following two blogs,
    Part 1: /people/sap.user72/blog/2005/11/24/xi-configuring-ccms-monitoring-for-xi-part-i
    Part 2: /people/sap.user72/blog/2005/12/05/xi-grmg-customizing-for-xi-ccms-heartbeat-monitoring-part-ii
    Configure the Alert Framework with the below Blog as reference,
    /people/michal.krawczyk2/blog/2005/09/09/xi-alerts--step-by-step
    Then forward the Alerts created in the CCMS to Alert Frame work, the required steps are given in the below help links.
    http://help.sap.com/saphelp_nw04/helpdata/en/3f/567ddea69d3d4c93a6aedabd08899e/frameset.htm
    http://help.sap.com/saphelp_nw04/helpdata/en/30/62e77b2f4865488a866d4103923a93/frameset.htm
    Then any alerts that gets generated in CCMS can be passed to the Alert Category kept configured in the Alert Framework.
    Hope this helps you

  • Can I define an RFC with multiple desitinations?

    I am working on intergration between SAP and JAVA, I am have to call RFC to get the pricing of a each lineitem from Java instead of getting from SAP Condition types while creating as Sales order. I have defined one RFC to connect to Java server program. I have called that in Exit routine of that condition value.This should happened online as soon as you creat a sales order you have to get the relavant price of each material.I can able to get the things .I need to test the performance of this if data is huge. I need some help regaring this.
    Can I call multiple RFC destinations to connect the Java server program if it is excecuted as clusters or different severs .

    I had a similar requirement. They want to call different RFC destinations in different systems. So, I created a table with System and Logical destination to be called from that system.
    In my code, I check the current system and get the logical destination to be passed while calling function module. You can also use similar logic if you want to call different systems.
    Chakri.

  • RFC - Soap(Webservice_1, webservice_2) multiple recevers with synchronous

    Hi Experts,
    My scenario is RFC <-> Soap(Webservice_1, webservice_2) multiple recevers with synchronouse
    I get campus_code field from RFC, when campus_code is 25 i need to call webservice_1 , when the campus_code is 35 i need to call webservice_2 as synchronouse call.
    Can you please tell me how to implement step by step in recever determination.
    Thanks
    Dhanush.
    Edited by: Dhanush on Jun 16, 2008 5:03 PM

    Hi Dhanush,
        Did you try to give a condition in the XPATH Condition editor of the receiver determination section?
    1) Click on the Condition editor button in the receiver determinatuion section.
    2) YOu will get a pop up screen.
    3) On the left hand side of the expression, give the XPATH for the CODE_ID (YOu can use the serach help button to chose your source field.
    4) Chose the relation operator as '='.
    5) On the righ hand side of the expression, GIve the constant value 35.
    Press OK.
    Chose the corresponding party and service for your weservice1.
    Do the same in next line for webservice2.
    After that, you have to define separate Interface determination and receiver agreement for webservoce1 and webservice2 scenarios.
    Regards,
    Ravi

  • How do you use multiple displays with a MacBook Pro and iMac

    I have an iMac and a MacbookPro laptop both upgraded to OS X 10.9 (Mavericks).  I'd like to use multiple displays with them.  Can I do this without an Apple TV?  They are both on the same network.  If I can, can someone please give some instructions on how this can be done?
    Thanks!

    Both computers have ports for external monitors. Check your user manuals. Only one display can be added to the MBP, but newer iMacs have dual Thunderbolt ports.
    Do your own Google research to learn what to do, but reading your manuals should be all you really need. It' not rocket science yet.

  • Multiple problems with Mail

    Here is the setup:
    iMac Intel running 10.4.8
    Mail 2.1.1
    seperate user accounts, each with their own email address
    email is valornet.com (local ISP), set up to download to Mail
    Multiple problems with one of the user accounts (not affecting the others):
    1. Multiple copies in the inbox of the same message. These are brand new, not a week old as some other threads have mentioned. When I go to Preferences/Accounts/Advanced I have already clicked the "Remove Now" button, also the "Remove copy from server..." is checked.
    2. Mail will not stop retrieving new mail. The circle thing next to the Inbox on the left just keeps spinning, and spinning, and spinning...
    3. Cannot quit Mail. Have to go in Activity Monitor and Force Quit.
    4. My trash folder is gone.
    If anyone can help me clean up this mess, I would appreciate it.

    Verify/repair the startup disk (not just
    permissions), as described here:
    Th
    e Repair functions of Disk Utility: what's it all
    about?
    Minor bitmap problem needed fixing; fixed.
    Go to Apple Menu > System Preferences >
    Network, choose Network Port
    Configurations from the Show popup menu,
    and make sure that the configuration used to connect
    to Internet appears at the top of the list.
    It was showing Bluetooth first and ethernet 2nd; I moved ethernet to the top.
    In Mail, open Window > Activity Viewer. What
    do you see Mail doing there? Actually, you may be
    able to avoid having to force quit Mail by canceling
    whatever it’s doing (by clicking on the red stop icon
    of the activity).
    "Fetching new mail
    Fetching 5 of 5: updates on buses - Haskell Middle School"
    blue bar is moving, red stop icon is bright. I clicked on the stop icon and it "grayed out" but Mail did not stop the spinning circle next to the inbox. Still had to force quit.
    What are your Mail > Preferences > Accounts >
    Mailbox Behaviors > Trash settings?
    Trash can is back! One problem solved...
    Do you have any Mail plug-ins or any system utilities
    that could interfere with Mail? In the Finder, go to
    each of the following folders (if they exist). What
    do you see there?
    /Library/InputManagers/
    ~/Library/InputManagers/
    /Library/Mail/Bundles/
    ~/Library/Mail/Bundles/
    None of the above folders exist.
    In the user's ~/Library/Mail/ folder (the user with the problems), she has:
    DefaultCounts
    Envelope Index
    LSMMap2
    MessageRules.plist
    MessageRules.plist.backup
    OpenedAttachments.plist
    SmartMailboxes.plist
    and the following folders:
    Mailboxes
    [email protected]
    Signatures
    The Mailboxes folder has two more folders inside:
    Deleted Messages.mbox
    Outbox.mbox
    The POP-... folder has the following folders inside:
    Deleted Messages.mbox
    Drafts.mbox
    INBOX.mbox
    Sent Messages.mbox
    and one file:
    MessageUidsAlreadyDownloaded2
    Incidentally, I now have 9 copies of the same email in my inbox and 7 copies of another. They are multiplying like rabbits!
    Thanks for your help so far.
    17" iMac (intel)   Mac OS X (10.4.8)  

  • Flat File-to-RFC question, multiple RFC calls for one file.

    Hi guys,
    I'm quite new to XI / PI and I have a question regarding a File-to-RFC scenario we're trying in NW PI 7.1.
    We have a flat file which has two lines with two fields each, let's take this as an example :
    001,001
    002,002
    The files needs to be converted to XML and then transferred to the RFC program which will update a table with the values above.
    In the ESR I've created 3 data types (z_row1,z_record1 and z_fileinput1), 1 message type (z_file2rfc_ob_mt), 1 message mapping (z_file2rfc_mm), 2 Service Interface (z_file2rfc_ob_si and z_file2rfc_ib_ztestpi) and 1 operation mapping (z_file2rfc_om).
    In the Integration Builder (ID) I've created everything required (The sender and receiver communication channels, sender and receiver agreement, receiver determination and interface mapping).
    We're also using content conversion to convert the flat file to XML, this does seem to work because I see all the lines/field in the message when it gets into PI. The problem is that the RFC can only accept two fields at a time and only the first line gets updated. I see that only the first line gets sent to the RFC.
    How can I make the RFC call for each and every line ?
    Thanks !!

    Create the RFC with table, which takes multiple lineitem as input and update the table in single call.
    If you want response back then call RFC as synchrounous else in Asynchrounous mode.
    By doing this in single call it will update the complete table.
    Gaurav Jain
    Reward Points if answer is helpful

  • Multiple RFC calls in same session

    Hi All,
    I'm looking for a way to execute multiple RFCs (one after the other) within the same "session".  The reason I need to execute them within the same session is because the initial RFCs store information in ABAP memory (EXPORT x TO MEMORY ID y) and subsequent ones will use that information (IMPORT x FROM MEMORY ID y) for further processing.  I thought I could do it all as a transactional RFC call but as one of the RFCs invokes the GUI, it seems to cause complications.  I don't think tRFCs are the correct solution because it invovles client interaction from the GUI in one of the calls.
    Has anyone tried to do this with the .NET Connector before?  I've tried reusing the connection but it seems to get reset after the first call.  Please help!
    Tim.

    Hi Tim,
    How are you doing ?
    A session [when using NCo] is the length of time that the connection is open.
    please let me know why the connection is being reset.
    the client number is a mandatory attribute in any connection string, it is a part of a composite key which uniquely identifies the user
    please let me know how you would like to proceed ?
    with respect,
    amit

  • How to loop through single XML File and send multiple RFC calls?

    I am looking for the best approach to use for making multiple RFC calls (can be sequential) using a single XML file of data.  I have been attempting to get a BPM loop working, but to no avail.  My RFC only accepts a single set of delivery input and I have been told to try to work with it as is.
    input xml sample:
    <?xml version="1.0" encoding="UTF-8"?>
    <ProofOfDelivery>
       <POD>
          <delivery_number>1</delivery_number>
          <carrier_name>UPS</carrier_name>
       </POD>
       <POD>
          <delivery_number>2</delivery_number>
          <carrier_name>UPS</carrier_name>
       </POD>
    </ProofOfDelivery>
    I need to make a synchronous RFC call for each set of POD data.
    Thanks in advance!

    Thanks for the inputs.
    I tried with a BPM and multi-mapping transformation before a ForEach block.  I am getting this error:
    Work item 000000028028: Object FLOWITEM method EXECUTE cannot be executed
    Error during result processing of work item 000000028029
    com/sap/xi/tf/_ProofOfDeliveryMultiMapping_com.sap.aii.utilxi.misc.api.BaseRuntimeExceptionRuntim
    Error: Exception CX_MERGE_SPLIT occurred (program: CL_MERGE_SPLIT_SERVICE========CP, include: CL_
    Probably because I am not making/using the container objects properly.  Here is a screenshot of my BPM.  Can anyone spot my issue or point me to an example on this sort of container use?
    [http://kdwendel.brinkster.net/images/bpm.jpg|http://kdwendel.brinkster.net/images/bpm.jpg]
    Thanks

  • Home Monitoring and Control with a third party also monitoring and controllin​g?

    I was wondering if anyone has tried to install Home Monitoring and Control with a third party monitoring, and or controlling the same devices. I know many systems offer multiple control points such as auxilary control touch screens. Has anyone made this work? I have Z wave devices on my home security system (lighting), and would also like to monitor them via Verizon. Possibly also adding some energy monitoring and control, that is not available via my security company. My security monitoring company provide support through Alarm.com, but has limited energy monitoring to thermostat control and such.
    The only interactive control with my security company is for alarm monitoring and control, with limited lighting control. All of my devices are GE in the wall mounted lighting controls, and I would prefer to pay Verizon the few extra dollars for the additional features VIA the web, rather than pay Verizon. There used to be an energy package, that included the main power panel load and I thing Thermostat, but I believe some of the bundles have been split up.
    There are other options out there now, but I have neen exploring. My GE Switches are from the Lowes Iris system. Much less expensive, and can replace existing wall switches, not like the power cord switches. Plus the store is four miles from my house.

    I started with Verizon home monitoring, but if you read through the threads the service is extremely unreliable, still to this day. I am stillusing it, although I am waiting for a refund on the services that I have used since it is so bad but I bought a MiCasaVerde Vera3 system.  You pay appoximately $300 for the unit and there is no monthly charge and you get all the features plus pretty much unlimited types of z wave devices to use on it. I would seriously consider using that before Verizon.

  • Monitor multiple phone for incoming call

    Hello,
    I want to monitor multiple phone incoming call (retrieve callerID, ...)
    I do that with Tapi, but when you configure TSP, it's only for one phone
    I can install TSP several times, but ... for 40 phones ...
    Are there other solutions ?
    I use CCME

    Yes, you can use packet capture to sniff skinny. It works really well, and transparently across CallManager and CallManager Express. You'll need to perform packet decode which is a bit of work, and connect your server to the appropriate SPAN port, of course.

Maybe you are looking for

  • Can you add a Print Button to one page?

    I have a form with 15 or so pages of information.  I do not want the submitter to get a printout of the entire thing.  However, they are given a chance to pay via PayPal or pay by mailing a check. If they chose PayPal, no big deal.  If they chose to

  • I downloaded songs to iPhone from cloud and now I can't get rid of them.

    How do you get rid of music from the iPhone.  I try to sync but they won't go away.  I even turned off the cloud.

  • Overdrive

    I updated my overdrive app and now it will not let me open it. I reloaded adobe but I do not know how to open on an iPad. Any suggestions

  • E-mail via Workflow task is not send they say aprox once a month

    Hi there I am asked to check one system with a “workflow” running 2+ years. It is actually an task with method which sends an e-mail when Purchase requisition is created. It istriggered by event in user exit(via function). The version is IS oil 4.6C.

  • Responsive Nav Issue

    I've asked a lot of questions on here about the responsive nav on my site and I have 2 last issues with it. 1. I want the nav bar to behave as it does, but be centered on the screen.  Can't seem to get it off of the left. 2. The drop down menu under