Multiple bank exist. Please specify bank to use.

Hi All,
While clearing vendor account through transaction code F-51, system is displaying error "Multiple bank exist. Please specify bank to use".
Vendor master has two bank accounts with BnkT (Bank type) as 01 and 02 respectively.
Thanks

Hi
Document you are planning to clear was posted that time may be only one bank type in vendor master has been assigned.
check which bank type assigned that time and keep that bank type and clear the vendor.
Rgds
Vani

Similar Messages

  • N7K F1 TCAM limitations ("ERROR: Hardware programming failed. Reason: Tcam will be over used, please enable bank chaining and/or turn off atomic update")

    Platform/versions:
    # sh ver
      kickstart: version 6.2(2)
      system:    version 6.2(2)
    # sh mod
    Mod  Ports  Module-Type                         Model              Status
    1    32     10 Gbps Ethernet Module             N7K-M132XP-12      ok
    2    48     1000 Mbps Optical Ethernet Module   N7K-M148GS-11      ok
    3    32     1/10 Gbps Ethernet Module           N7K-F132XP-15      ok
    4    32     1/10 Gbps Ethernet Module           N7K-F132XP-15      ok
    5    0      Supervisor Module-1X                N7K-SUP1           ha-standby
    6    0      Supervisor Module-1X                N7K-SUP1           active *
    I recently tried to add a couple of "ip dhcp relay address" statements to an SVI and received the following error message:
    ERROR: Hardware programming failed. Reason: Tcam will be over used, please enable bank chaining and/or turn off atomic update
    Studying this page I was able to determine, that I seemed to be hitting a 50% TCAM utilization limit on the F1 modules, which prevented atomic updates:
    # show hardware access-list resource entries module 3
             ACL Hardware Resource Utilization (Module 3)
                              Instance  1, Ingress
    TCAM: 530 valid entries   494 free entries
    IPv6 TCAM: 8 valid entries   248 free entries
                              Used    Free    Percent
                                              Utilization
    TCAM                      530     494     51.75 
    I was able to workaround it be disabling atomic updates:
    hardware access-list update default-result permit
    no hardware access-list update atomic
    I understand, that with this config I am theoretically allowing ACL traffic during updates which shouldn't be allowed (alternately I could drop it), but that's not really my primary concern here.
    First of all I need to understand why adding DHCP relays are apparently affecting my TCAM entry resources?
    Second, I need to understand if there are other implications of disabling atomic updates, such as during ISSU?
    Third,  What are my options - if any - for planning the usage of the apparently relatively scarce resources on the F1 modules?

    Could be CSCua13121:
    Symptom:
    Host of certain Vlan will not get IP address from DHCP.
    Conditions:
    M1/F1 Chassis with Fabric Path Vlan with atomic update enable.
    On such system if configured SVI with DHCP is bounced that is if we shut down and bring it up may cause DHCP relay issue.
    Workaround:
    Disable Atomic update and bounce the Vlan. Disabling Atomic update may cause packet drops .
    Except that ought to be fixed in 6.2(2).

  • I have got an iPhone MC605J version 6.0 soft bank iphon 4 but unable to use it in India.  I am trying to use Airtel sim but the phone is showing invalid sim.  So please help me out to unlock it.

    I have got an iPhone MC605J version 6.0 soft bank iphon 4 but unable to use it in India.  I am trying to use Airtel sim but the phone is showing invalid sim.  So please help me out to unlock it.

    No one here can help you, & Apple can't/won't help you. Fact is, there is no way to get that iPhone officially unlocked. Only Softbank can authorize the official unlocking of your phone, but they won't. Softbank does not offer official unlocking for any iPhone.
    It is what it is.

  • Exchange 2007 Management shell issue: "There are multiple objects matching the identity "servername" Please specify a unique value"

    I thought this would be an easy answer to an issue I'm facing, but there's a problem executing the solution.
    I'm running Exchange 2007 in a clustered SCC configuration.  The clustered resource is called "DENBURYMAIL."  I want to give my account full mailbox access rights to all the mailboxes in this resource/database.
    I believe I found the solution to this at
    http://technet.microsoft.com/en-us/library/bb310792%28EXCHG.80%29.aspx (about halfway down the page) the instructions read as follows: 
    ==============================
     Q: I have a third-party messaging application that requires full access to each user's mailbox. With Exchange Server 5.5, we grant a special account the Service Account Admin permissions, and then tell the application to use this account. How
    can I achieve similar functionality in Exchange 2007?
    A: Exchange 2007 security works differently from that of Exchange Server 5.5. In fact, Exchange 2007 does not use a site service account. Instead, all services start as the local computer account.
    If your logon account is the Administrator account, a member of the root Domain Administrators, a member of the Enterprise Administrators groups, or a member of the Exchange Organization Administrators role, you are explicitly denied access to all mailboxes
    that are not your mailbox, even if you have full administrative rights over the Exchange system. All Exchange 2007 administrative tasks can be performed without having to grant an administrator sufficient rights to read other people's mail.
    You can achieve the results that you want in the following ways, but do so only in accordance with your organization's security and privacy policies:
    In the Exchange Management Shell, use the following command to allow access to all mailboxes on a given mailbox store:
    Add-ADPermission -identity "mailbox database" -user "serviceaccount" -ExtendedRights Receive-As
    =============================
    But when I run the command (Add-ADPermission -identity "denburymail" -user "matthew.fazio" -ExtendedRights Receive-As) I get an error telling me that "There are multiple objects matching the identity "DENBURYMAIL."  Please Specify a unique value."
    I'm not sure what's causing this-- why are there "multiple objects?"  Is this a problem due to operating in a clustered environment?
    Any assistance would be appreciated!

    It may not be specific enough for the command to understand you.
    Try this:
    Get-MailboxDatabase -Server <servername> | Add-ADPermission -user "matthew.fazio" -ExtendedRights Receive-As

  • Creating Multiple Bank Branches for a Bank in 11i

    Hello All,
    I am currently trying to create multiple Branches for a Bank in Oracle apps 11.5.10. But I am not able to create.
    I am performing the following procedure:
    Payables, Vision Operations (USA) --> Setup --> Payment --> Banks
    I am able to create one branch but not able to create multiple branches.
    Any suggestion on creating multiple branches for a Bank will be helpful.
    Thanks & Regards
    Aboothahir

    Hello
    The first question you need to answer is are your branches defined as Operating Units in 11i. If they are, Each Payable Manager responsibility can be attached to only one Operating Unit. (Effectively meaning to One Branch only). In which case, you need to define Separate Payable Manager responsibilities for the different Operating Units/Branches.
    But looking at your question again, what i seem to understand is that this may not be your requirement. Your organisation is not a bank, but a company that needs to create separate bank accounts under one bank. Is my understanding correct?
    In which case, follow the below mentioned navigation path
    Payables > Setup > Payment > Banks > [select your bank] > Bank Accounts > And the click on the Bank Account Name and use the down button.
    This will eventually lead to a blank field which will enable you to define a new bank 'ACCOUNT' (Not a branch. But i presume the purpose is still the same?')
    Hope this helps. Do update me if i'm not clear,
    Miranga

  • My i phone 4s will let me download free apps but when i try to buy an app it asks for my billing imformation and tells me that the. Imformation i typed in does not mach my bank records. Ive also tried using my wifes. Any ideas

    When i try to buy an app from the app store it ask for my billing imformation and when i type everything in it tells me the imformation does not match my bank records. Ive also tried using my wifes card to buy apps and it says the same thing. Any ideas?

    The Apple Support Communities are an international user to user technical support forum. As a man from Mexico my first language is Spanish. I do not speak English, however I do write in English with the aid of the Mac OS X spelling and grammar checks. I also live in a culture perhaps very very different from your own. When offering advice in the ASC, my comments are not meant to be anything more than helpful and certainly not to be taken as insults.
    Are you putting in the address where the bank sends the monthly statement?
    Apple's servers are very picky about the format of the address. If you live in the USA, then the server is expecting the style that the US Postal Service uses. One way to do this is to use the USPS ZIP Code lookup service;
    https://tools.usps.com/go/ZipLookupAction!input.action
    Enter the address to look up the ZIP code and then copy the exact USPS output into your iTunes account information.

  • I made a card using the iPhoto and when I click to buy it, it says that I did not fill all the frames with pictures, even though I did and have checked multiple times. Please help, it's for Mother's Day.

    I made a card using the iPhoto and when I click to buy it, it says that I did not fill all the frames with pictures and that I need to in order to purchase it, even though I did and have checked multiple times. Please help, it's for Mother's Day.

    Before ordering your book preview it using this method - http://support.apple.com/kb/HT1040 - and save the resulting PDF for reference - the delivered book will match it.
    LN

  • Sign into iCloud pop-up message on iPad2 won't disappear off screen, have reset password multiple times but it is saying incorrect. Please HELP unable to use iPad as message appears every few seconds, iPad was working fine until now.

    Sign into iCloud pop-up message on iPad2 won't disappear off screen, have reset password multiple times but it is saying incorrect. Please HELP unable to use iPad as message appears every few seconds, iPad was working fine until now.

    After the restore did the phone work properly for a while? Say, a day or so?
    If so it is possible you have an app that doesn't let go of memory properly. I reboot my iPhone ( hold sleep/wake and hole till you see the apple logo) every few days. This resets the memory. The iPhone OS has doesn't seem to mange memory very well yet. So a reboot will help with that. I have had my phone almost slow to a stop before I started rebooting. Always reboot after installing a new app. Also do you close all pages in Safari when you are done? This is a good practice. Safari will run in the background and use processor time and drain your battery quicker. Create a new blank page then close all others when you are done browsing for a while. I have also found that certain web site that have animated images like weather maps will turn the phone into molasses. As soon as i close that page it gets faster.
    If all of the above have no effect then as Tamara said it is time for a trip to the Genius bar.
    Good luck

  • How can i safely segregate certain cookies (such as my bank's) so that i can use the delete all cookies feature but preserve those cookies?

    how can i safely segregate certain cookies (such as my bank's) so that i can use the delete all cookies feature but preserve those cookies? windows xp, firefox 13.0.1

    You can't delete all cookies if you want to preserve some of them.
    You will have to let all cookies expire when you close Firefox and create an allow exception for cookies that you want to keep and only clear cookies manually and not via Clear Recent History.
    *Tools > Options > Privacy : History: [X] Clear history when Firefox closes > Settings
    *https://support.mozilla.org/kb/Clear+Recent+History
    You can also consider to access website in Private Browsing mode if you do not want to store data to disk form those websites.
    *https://support.mozilla.org/kb/Private+Browsing

  • My order have a status: "Payment action required: We are unable to obtain an authorization for the credit card you provided. Please contact your card issuing bank. Please update your payment method to continue with this order". But i paid from AmEx.

    My order have a status: "Payment action required: We are unable to obtain an authorization for the credit card you provided. Please contact your card issuing bank. Please update your payment method to continue with this order". But i paid from AmEx. And my money blocked when i see it in internet banking.

    Have yuo contacted AmEx? From what you describe it seems like AmEx is blocking the charge.
    You can contact iTunes if you want by:
    Contact iTunes

  • Automatic bank reconciliation with Electronic bank statement

    Deal All,
    As mentioned in the subject of this mail, this is to request for your inputs to advice the configuration steps with process for Configuration of Electronic Bank Statment in R3 to eneble the user for automatic bank reconciliation with clearing customer/vendor open items.Please send confi doc.
    Request you to provide documentation if possible along with your valuble advices.
    cvs

    Hi
    I implemented the EBS in my company 4 month ago and here are some advises on the problems i experienced in the setup process. As for the setup process it is straightforward just read the manual at help.sap.com.
    We used the MT940 format for importing bank statements from our bank.
    The first thing i would advice you to do is make a list of all the possible transactions that are to be handled by the EBS application.
    Then make estimation of how many payments that are recieved in constant structured way which the EBS can handle. (invoice number in the text)
    The people in our accounting department complained alot about the output format in the EBS not being userfreindly compared to the advises they recieved in e-mail form from the bank so if not the bulk of your payments can be processed automatically it might not be worth the trouble to implement it. (i still think they uses the the email to postprocess the transactions that was not automatically cleraed)
    Make sure you havent got any other applications handling some of the transactions that are contained in the bank statement because this wont work. eg. we had a program automatically placing fx trades on customer and bank account which meant that when we recieved the fx trade on the statement it was already placed and therefore had to be placed on a interims account for later reversal.
    We get alot of bankcharges on our payments and we set up the EBS to place them automatically on a bankcharge account if the difference between the recieved amount on the invoice was less that 30 dollars.(we just assume that a difference is a bank charge) This means that a customer if he wants to always can pay x dollars under the invoice amount because it will be automatically processed and therefore go unnoticed.
    Establish a contact in your bank who knows how their MT940 format has been structured. 
    Then contact your bank and get them to provide some test statements of old bank statements.
    Make sure that you are not the first customer for using the MT940 format or else you will end up being ginny pig for the banks possible mistakes.
    As i learned the way banks interpret the MT940 format guidelines can varry quite alot eg. the ocmt field our bank interpreted as the original payed amount in its original currency. SAP inprets this field as the recieved amount in its original currency and therefore it always try to clear the OCMT amount if availleble which meant it always tried to clear the original amount even though there had been taken som bankcharges underways.
    I also found out that our bank didnt really bother to specify the type of transaction (interest, fx contract, bank charges, check and so on) which meant we only had two external transaction codes availleble s103 for incomming payments and ntrf for outgoing payments. This gave alot of trouble as i had to identify the type of transaction through seach algorithms.
    Our bank also had trouble creating the MT940 file because it has a limited number of characters availleble which meant in the initial file that it only gave the first x characters of each line and then left out the rest. This meant that the text was broken into alot of pieces and you hardly ever had a complete invoice number to clear on. We had the bank altering their format so they now leave out text at the end of the transaction instead.
    In the implementation process we experienced that the EBS application created a payment advice each time the amount of the payment didnt match the invoice in the system. We implemented a note from service.sap which disabled this and just assigned the difference to a bankcharge account.
    I dont know if you can use these advices but just felt i would try to warn you about the potential problems that i experienced in the process. .
    If you have concrete questions to the EBS setup feel free to contact me and i will see if i can help you.

  • E proxy Please specify secure port in the properties.

    Hi,
              I have a cluster of two weblogic servers as 192.168.80.144 and
              192.168.80.147 both are in NT. I have installed weblogic in both m/c in
              same folder. Do I need to put the same port number ( what port number
              443 ? or anyone ? ) in [weblogic]/weblogic.properties and
              [weblogic]/[mycluster]/weblogic.properties. I have tried putting 443 and
              7001. Then what ip-address will be used to put the request ? I tried to
              request on mycluster:443 and mycluster:7001 where mycluster is the name
              of the cluster in both m/c and there is an entry in hosts file of NT for
              192.168.80.144 and 192.168.80.147 as mycluster.
              After starting the server it says
              Tue May 22 10:00:54 CEST 2001:<I> <Cluster> Adding server
              7537245419133606340S192.168.80.147:[443,443,7002,7002,443,-1]
              to cluster view
              Tue May 22 10:00:58 CEST 2001:<I> <NT Performance Pack> Allocating: '2'
              NT reader threads
              Tue May 22 10:01:05 CEST 2001:<I> <WebLogicServer> WebLogic Server
              started
              Tue May 22 10:01:57 CEST 2001:<I> <ServletContext-General> *.html: init
              When I send the request thru browser it says following:
              Tue May 22 10:01:57 CEST 2001:<E> <proxy> Please specify secure port in
              the properties. Using default ports 7001/7002 Se
              e release notes for more info
              Tue May 22 10:01:57 CEST 2001:<E> <proxy> Please specify secure port in
              the properties. Using default ports 7001/7002 Se
              e release notes for more info
              Please suggest me what to do for running the cluster properly.
              Thanx in advance.
              Vinay Kumar
              Gauss Interprise AG Phone: +49-40-3250-1226
              Weidestrasse 120 A Mobile: +49-177-7906818
              D-22299 Hamburg mailto:[email protected]
              Germany web: http://www.gauss-interprise.com
              [att1.html]
              

    Clustering is a big topic that cannot be explained in one post. That was why I suggested the link for a complete explanation. The link does provide tons of information you need to setup a cluster.
              However, here are some pointers for your case as applicable to WebLogic 5.10 clustering (which is what you seem to be running).
              (1) Weblogic properties have the following precedence (properties defined in the first item in the following list override the same properties defined in the second item in the list and so on): command line properties, per-server property file, cluster-wide property file and finally global property file.
              If you installed Weblogic 5.10 under /weblogic and your cluster is called "mycluster" and your server is called "Server1" and you command line script is stored in a file called "startServer1.cmd" under /weblogic, then weblogic will read the properties in the following order (the latest read overrides the same properties from an earlier read):
              (a) /weblogic/weblogic.properties <-- global property file
              (b) /weblogic/mycluster/weblogic.properties <-- cluster-wide property file
              (c) /weblogic/mycluster/Server1/weblogic.properties <-- per-server property file
              (d) properties defined in startServer1.cmd <-- command line properties
              In your case, a good place to place the port number is in the cluster-wide property file (since all servers in the cluster should use the same port). Do not specify any ports in the per-server property file or in the command line properties in this case as they will override the port specified earlier.
              (2) In 5.10, you will typically have a bank of webservers (Apache, Netscape, IIS) in front of the cluster. Several configurations are possible. You can for instance have a hardware load-balancer in front of the webserver. You can then have the DNS serve up the external IP of the load-balancer. Alternatively, you can also do DNS round-robin among the webservers. Clients will then use the DNS name in the URL which will map to either the load-balancer or one of the webservers.
              Check this link out for details on architecture:
              http://www.weblogic.com/docs51/cluster/planning.html#1040272
              Giri
              "Vinay Kumar" <[email protected]> wrote in message news:[email protected]...
              Hi Giri,
              From this very link I got the idea to use weblogic cluster.
              So this is not of much help.
              Thanx.
              Giri Alwar wrote:
              Take a look at the following document: http://www.weblogic.com/docs51/cluster/index.html Giri
              "Vinay Kumar" <[email protected]> wrote in message news:[email protected]... Hi,
              I have a cluster of two weblogic servers as 192.168.80.144 and 192.168.80.147 both are in NT. I have installed weblogic in both m/c in same folder. Do I need to put the same port number ( what port number 443 ? or anyone ? ) in [weblogic]/weblogic.properties and [weblogic]/[mycluster]/weblogic.properties. I have tried putting 443 and 7001. Then what ip-address will be used to put the request ? I tried to request on mycluster:443 and mycluster:7001 where mycluster is the name of the cluster in both m/c and there is an entry in hosts file of NT for 192.168.80.144 and 192.168.80.147 as mycluster.
              After starting the server it says
              Tue May 22 10:00:54 CEST 2001:<I> <Cluster> Adding server 7537245419133606340S192.168.80.147:[443,443,7002,7002,443,-1]
              to cluster view
              Tue May 22 10:00:58 CEST 2001:<I> <NT Performance Pack> Allocating: '2' NT reader threads
              Tue May 22 10:01:05 CEST 2001:<I> <WebLogicServer> WebLogic Server started
              Tue May 22 10:01:57 CEST 2001:<I> <ServletContext-General> *.html: init
              When I send the request thru browser it says following:
              Tue May 22 10:01:57 CEST 2001:<E> <proxy> Please specify secure port in the properties. Using default ports 7001/7002 Se
              e release notes for more info
              Tue May 22 10:01:57 CEST 2001:<E> <proxy> Please specify secure port in the properties. Using default ports 7001/7002 Se
              e release notes for more info
              Please suggest me what to do for running the cluster properly.
              Thanx in advance.
              Vinay Kumar
              Gauss Interprise AG Phone: +49-40-3250-1226
              Weidestrasse 120 A Mobile: +49-177-7906818
              D-22299 Hamburg mailto:[email protected]
              Germany web: http://www.gauss-interprise.com
              Vinay Kumar
              Gauss Interprise AG Phone: +49-40-3250-1226
              Weidestrasse 120 A Mobile: +49-177-7906818
              D-22299 Hamburg mailto:[email protected]
              Germany web: http://www.gauss-interprise.com
              [att1.html]
              

  • What is the criteria for selecting a license if multiple licenses exist

    Hello experts,
    If multiple licenses exist for an order in GTS, what is the criteria to decide which license will finally be selected?
    The log says "Number of import/export licenses that could be affected: 3" but it finally picks up one.
    Does it do it sequentially using the internal license number?
    We have a scenario where we are upgarding from version 7 to version 10, and there is one license (say A) which was created in the older version and copied to the new system after upgrade. There is also a new license (say B) directly created in the new version (with same selection criteria as A)
    Now when an order is created, both licenses are "affected" but it picks up the license B created in the new version.
    If the system was picking license based on internal number it should have picked up license A which was created in earlier version (as that had a lower internal number sequentially). If I expire license B and recheck the order, then it correctly picks up A.
    So what is the actual criteria to select a license and in this case was License A not given priority because it was created in older version and then copied to new version as part of upgrade?

    As far as I can see from a quick look at the code, there is no attempt to place the determined licences in any particular order.  Since they are selected from table /SAPSLL/LCLIC, it seems reasonable that they would be selected according to field GUID_LCLIC.  Within one system, the GUIDs remain in order of creation date/time; however I don't know GUIDs are formed in relation to different systems.  My bet is that if you check in SE16, your "early" licence actually has a higher GUID value than the recent ones.
    Please check, and see if I'm right.
    Regards,
    Dave

  • Payment Method "Bank Transfer" in House Bank?

    Hi Experts
    1. I have created a Payment method as Bank Transfer - "B".
    2. Assigned it to the Company code
    3. Created a Bank Account in a House Bank with Payment Method Bank Transfer - "B".
    4. i have created a Vendor given the Bank details and choosen the payment method B.
    5. Now when i post the invoice in F-43 i want the payment has to be happen in the vendor bank directly.
    please help me what additional configuration i need to do for the above task.
    Regards
    RAJA

    Dear Raja,
    please run FK03 for Your vendor --> General data --> X Payment transaction
    You can use the field Partner Bank Type LFBK-BVTYP to define a key (example 1,2,3,4 OR A,B,C..) that You can choose and insert during the invoice posting so the System will use this vendor bank during the automatic payment
    or
    FK03 --> Company Code data --> x Payment transaction --> field Short Key for a House Bank LFB1-HBKID that mean:
    The key for the house bank is used if the customer/vendor is always to be paid by the same house bank. The bank selection of the payment program is cancelled with this entry.
    I hope this can help.
    Mauri

  • What is bank key in house bank configuration

    hi
    what is bank key in house bank configuration. is bank key same as our bank routing number.
    thanks,
    monica

    Hi,
    You specify the bank key under which bank data from the respective country is stored.
    Basically, your banks are managed by using their bank numbers. The bank number and the bank key are almost same for the house bank.
    Like you said, you may define a 9 digit number that serves as a routing number too.
    Hope it clears your doubt.
    Assign points if helpful.
    Regards,
    NareN.

Maybe you are looking for

  • Excel Viewer: Class not registered (error -214722116​4)

    Hello, I am using the Excel examples shipped with Labview 8.21 to read from an Excel file and this works well. Now I need to do the same but on a PC that does not have Microsoft Office or Excel installed but only the free XLVIEWER (Microsoft Office E

  • 1st Gen iMac G5 (pre Intel) kaput - worth the trouble?

    Unlike the other posts I've read here, my iMac doesn't even try to start up. I've held down the power button, disconnected and reconnected the power cord, tried a different outlet, and the ol' girl does nothing. Zilch. I suspect she may have died. My

  • Macbook Pro vs imac vs MacPro

    Hey Everyone, I've looked around the forums but I haven't been able to find an answer that quite fits my question/situation so I thought I'd try my own. Here it goes. I'm currently running a MacBook Pro 2.0ghz core duo with 1GB of RAM. (1GB on one sl

  • Black Preview // No Picture in Premiere Pro CC 2014 // MCP Retina 15" (2013)

    Dear fellow Premiere Pro users, I am facing a problem recently. When editing it quite often happens that the picture in the sequence monitor and preview monitor from one moment to the other just turn black and stay so until I restart the app. I also

  • Uncommon Satin Waves Deflector Case for iPhone 4

    Is the Uncommon Satin Waves Deflector Case for iPhone 4 coming soon to Australia?