My Labview 6i evaluation version getting bad/unusua​l readings(a​nalog input/outp​ut) while when i use test panel of Ni-DAQ 6.9.0 i have good readings from my PCI-MIO-16​E-1 board.

If i used Lavbview 5.0 on same PC i don`t have problems.Sorry with my english!
Attachments:
TestPanel.jpg ‏103 KB
Labview.jpg ‏62 KB

I tried running one of the DAQ example programs and i got the same data and i only use the version of NI-DQA that shipped with my 6i version evaluation. About hides drivers i reinstall and double click in all of folders and sub folders. About my program i don`t think i have problems because is very simple but i send it to you for you help me. About two weeks i am around this problem and i can`t see evolution...
PS.: Sorry with my english
Best regards,
Nelson Ferreira
Student of ISEP College in Portugal
Attachments:
LerEntrada.vi ‏43 KB

Similar Messages

  • I want the PCI-MIO-16-E4 ad board driver file.

    I am  doing research in aerospace department Anna university. i am using the hotwire annemometer. Data acquisition  purpose using the PCI-MIO-16-E4 AD board. The driver file of the board is corrupted. so request you to send the driver file.
    thank you  

    Hi!
       The board you're using is quite old, check for NI PCI-6040E (which is said to be "formerly known as PCI-MIO-16E-4").  So you should search for that drivers, the one for PCI 6040.  See the attached links:
       PCI 6040E
       traditional DAQ
       devices supported by traditional DAQ
       This board is supported also by Ni-DAQmx, which is a newer set of drivers. Check for LV and OS compatibility....
       But... just a question, how do you say that driver is corrupted? Do you have a message from LV, or whatelse?
       Hope I can help...
    graziano
    PS.: Just a note, post these kind of requirement under Data aquisition, or DAQ forums, there you can find exactly what you need!

  • Test panel in NI DAQ/ Labview

    Hi
    I downloaded NI-DAQ and Labview 6i evaluation version to program my DAQ 6020E(BNC) . I clicked on MAX and in the "configuration tree" i see under "devices and interfaces" my DAQ device present, but when i right click on my device  i see  that the test panel is disabled .My O.S. is Windows Vista. Sometimes i get errors like" NI-Max" files stopped working or "shared" file stopped working etc. What should i do to enable "test panel" on Max? My aim is to program one analog output channel to generate 5.5Volt for which i need test panel. Without the test panel being active, is there an alternate way to do this? The green LED on DAQ board usually is on but occassionally it blinks but finally stabilizes to continuously on state.
    Regards

    duplicate post. Please don't ask the same question to multiple boards. Your question doesn't seem related to the student edition or Elvis either.

  • When installing a NI 5112, I get an error message when running the test panel.

    I have recently decided to reinstall my PCI 5112 high speed digitizer in a different computer, for practical reasons. After having installed the software, hardware and successfully passing the self test, an error (10800) occurs when running the test panels. The signal applied to the channel and the different parameters used, worked fine with the previous computer but not with this one. Any idea why?
    Thanks,
    Thomas

    Hello Thomas,
       The error code you are getting is related to the board not recording enough samples in the given time interval.  May I ask which series of PCI card you are using. This can be found by looking at the device in Measurement and Automation Explorer and looking under devices and interfaces. The series letter is the one on the end of the number after the hyphen. E.g. PCI-MIO-16E-4 would be an E-series board.
    Also which versions of Measurement and Automation Explorerand NI-Scope are you running? Are these the same versions as you used in the old PC system? Sometimes an upgrade in the version is all that is required to fix such a problem but unfortunately it can sometimes cause a problem if you upgrade! It would depend on the versions you are currently running and the series of the board that you are using.
    LeeM
    AE,
     National Instruments
    Message Edited by LeeM on 10-31-2006 10:47 AM

  • Cannot add a new reminider.  I am using and Iphone5, version 6.0.2.  When I press the reminder app on the phone there is no  "+" sign to input a reminder.  When I use Siri it says "sorry I wasnt able to create reminder".

    Cannot add a new reminider.  I am using and Iphone5, version 6.0.2.  When I press the reminder app on the phone there is no  "+" sign to input a reminder.  When I use Siri it says "sorry I wasnt able to create reminder".

    Many thanks.
    With those symptoms, I'd try the following document:
    Apple software on Windows: May see performance issues and blank iTunes Store
    (If there's a SpeedBit LSP showing up in Autoruns, it's usually best to just uninstall your SpeedBit Video Accelerator.)

  • Everytime I go to full-screen mode the photo I am working on is on one space while the filmstrip is on another. Also there is no way to get to the menu on top as it is hidden. When I hit the f key everything goes to black and I have to quite the program.

    Everytime I go to full-screen mode the photo I am working on is on one space while the filmstrip is on another. Also there is no way to get to the menu on top as it is hidden. When I hit the f key everything goes to black and I have to quite the program. This is the first time I have any problems with Aperture.
    I run aperture 3 on OS X 10.7 iMac 27" 2.8GHz i7 16GB.
    Thanks for any help.

    You have to change the cursor focus.
    What I usually do for PDF pages/tabs, is click in the URL/location bar, then F11.<br />
    For Flash, if you click on the page outside of the video area/box, F11 should work.

  • Simultaneo​us sampling with a PCI-MIO-16​XE-10 board.

    Hello,
    I work with LabView and a PCI-MIO-16XE-10 board.
    When I sample 2 channels, it's sampling channel 1 and after channel 2. like this:1 2 1 2 1 2 ..
    I want to sample the both channel on the same time, like (1-2) (1-2)...
    How can I do?
    Thanks for any answer

    You buy two boards
    I'm not familiar with that particular card, but generally they have a single
    digital to analogue converter and measure multiple channels with it by
    connecting it to each in turn. This is done very quickly and usually the
    time between channels is much less than the time between readings or the
    times over which the measured parameters vary and it's convenient to think
    of all the readings in each scan as being instantaneous even though they're
    not. If the switching time is significant to the application, then you need
    multiple A-D converters all triggered simultaneously.
    Check in the manual to see what the switching time is. What are you
    measuring that it's such a problem?
    tao wrote in message
    news:506500000008000000D4160000-984
    [email protected]..
    > Hello,
    > I work with LabView and a PCI-MIO-16XE-10 board.
    > When I sample 2 channels, it's sampling channel 1 and after channel 2.
    > like this:1 2 1 2 1 2 ..
    > I want to sample the both channel on the same time, like (1-2)
    > (1-2)...
    > How can I do?
    > Thanks for any answer

  • Can I have retriggera​ble analog out with a single intializat​ion with PC-6711 or PCI-MIO-16​XE-10 boards? step triggering available?

    i know i can use the counters to make retrigerable pulses, but i want to know if analog output can do this as well.

    Jay,
    It sounds like you want to update your analog output channels with a new value or an entire waveform every time you get a trigger signal. It's great that you're already familiar with counters creating retriggerable pulses, because you can use them for the analog output operation.
    The analog output channels get updated based on the edges of the update clock. You can use the counters to supply an external update clock. So, if you set up a counter for retriggerable pulse generation, it waits for a trigger signal. When it receives it, it generates a pulse, which you have wired to the analog output update clock. When the analog circuitry sees that edge, the data will be output to the channels.
    I answered a similar question regarding this for the posting
    "About trigger config". However, I realize that the user had originally posted in the LabVIEW General category, so it doesn't show here. Search the Developer Exchange for "retrigger analog", and you will find it. It discusses this idea as well as attaches a few examples that are currently going through a process of review to eventually be available on the web. There might be some other helpful postings as well.
    Another good resource for triggering in general is the NI Developer Zone "Tips and Techniques in DAQ Triggering" document. You can find it by going to the http://www.ni.com/support pages and searching for "daq triggering".
    Regards,
    Geneva L.
    Applications Engineer
    National Instruments
    http://www.ni.com/ask

  • When measuring 6 voltage signals in labview I found that there was a difference in voltage signals in my program but not in the test panel. The test panel is correct. What is wrong with my program?

    My labview program is not displaying equivelent voltages, but labview test panel is. So the computer is seeing the correct signals. My program is displaying a small difference in 3 out of 6 channels. All channels should be equal.

    G'Day Pops,
    You haven't really given us enough to go on - could you please post your VI so we can have a look at it?
    cheers,
    Christopher
    Christopher G. Relf
    Certified LabVIEW Developer
    [email protected]
    Int'l Voicemail & Fax: +61 2 8080 8132
    Aust Voicemail & Fax: (02) 8080 8132
    EULA
    1) This is a private email, and although the views expressed within it may not be purely my own, unless specifically referenced I do not suggest they are necessarily associated with anyone else including, but not limited to, my employer(s).
    2) This email has NOT been scanned for virii - attached file(s), if any, are provided as is. By copying, detaching and/or opening attached files, you agree to indemnify the sender of such responsibility.
    3) B
    ecause e-mail can be altered electronically, the integrity of this communication cannot be guaranteed.
    Copyright © 2004-2015 Christopher G. Relf. Some Rights Reserved. This posting is licensed under a Creative Commons Attribution 2.5 License.

  • How do I get an analog output signal from my PCI-MIO-16E-4 card?

    I need an analog output from 0-10 V to control the mass range on a mass spectrometer. Do I use the DAC0out channel to do this? The manual only talks about analog out (ao) channels. Is this the same as DAC0out and DAC1out? How do I set up the DAQ assistant for this process? I do not need a waveform, only a constant signal.

    Yes indeeded. The DAC0out and DAC1out are the analog output channels (ao0 and ao1).
    Simply follow the examples that ship with LabVIEW. You can also easily create code with DAQ assistant.

  • I keep getting a message about a bot running on my phone while trying to use the internet or Pinterest.  What is this?

    When using my phone off of WIFI I get warnings that there is a bot running on my phone (this does happen occasionally while connected to my WIFI).  This happens in safari and in Pinterest.  What does this mean, I can not search or post in Pinterest. 

        Let's make sure your Smartphone stays smart and keeps your apps working, Jennifer! Can you tell me exactly what it shown about the bot? Did this start after installing any recent applications or updates? Please try a soft reset by holding the Power and Home keys until device restarts.
    Thank you,
    YaleK_VZW
    Follow us on Twitter @VZWsupport 

  • How do I get my iPod touch to keep its place on music tracks when I use different apps?

    Since upgrading to IOS6 (iPod touch 4th generation) my iPod returns to the start of tracks rather than storing where I was up to if I stop listening to a track and use other apps. It's really annoying when listening to audio books that it won't keep my place.  How can I get it to keep my place again like it used to with IOS5

    You need to use iTune to sync music not Windows Media Player
    Allan

  • How can get the touchpad turned off when my logitech mouse is plugged via usb. when I used control panel to turn off tp it says it is disabled.

    both touchpad and mouse are active even though the touchpad is disabled

    I am saying that the touch pad still is active/turned on/ works, even though it is disabled according to the menu screen that I reach through control panel. It works all the time, in any program I am using. My latest attempt is to delete the software (Alps vers. 7.1207.101.225) but I see that has not worked either. I'm a poor typist and need to watch the keyboard and my thumbs touch the pad and send the cursor and current words somewhere other than the line on which I am trying to write. Very frustrating.[

  • Purchased Lightroom 5 (Student/Teacher version) - got my Redemption Code  and Serial Number but when I use codes provided the system will not finish loading. Have PC running Windows 7.  What is wrong?

    Help . . . Have the Redemption code and Serial Number as supplied on-line but can not install system using these numbers.

    Redemption Code Help
    http://helpx.adobe.com/x-productkb/global/redemption-code-help.html

  • I am trying to generate a 50kHz sine wave for ten cycles, then aquire this waveform and store it in a file, I am using a PCI-Mio 16E-4 board, has anyone done anything like this?

    I am trying to generate a 50kHz sine wave output on the DAQ card and then simultaneously recieve. I am using a PCI-Mio 16E-4 series board to do this. Has anyone done anything similar. I can generate a 50k wave no problem, and recieve one, but I can not get these vis to run together? Any suggestiosn

    Jrod, yes you should be able to do this, actually there are quite a few example programs come with LabVIEW that handles simultaneous analog input and output, I check the specs of the board you use, the board should be able to handle the sampling/generation rate, but make sure for 50KHz sine wave, you would sample at least twice as fast, preferably ten times the generation rate, then this puts the sampling of the board to thew limit.
    The program you can try is attached here, good luck with the application,
    XD Gao
    Applications Engineering,
    National Instruments
    Attachments:
    Simul_AIAO_Buffer(E-series).vi ‏104 KB

Maybe you are looking for