N7K-D132XP-15 module
Is there any N7K-D132XP-15 module. I have seen this module reference in many other Cisco presentation. Is this a typo and correction would be N7K-F132XP-15 or a new module expected to be announce...
Hello,
So the fabric module that we have on the nexus 7000 will supply 46gbps per slot for each module you add:
http://www.cisco.com/en/US/prod/collateral/switches/ps9441/ps9402/ps9512/Data_Sheet_C78-437760.html
Depending on the modules you are using will dictate how many fabrics you need. For example if you are using a N7K-M132XP-12L:
http://www.cisco.com/en/US/prod/collateral/switches/ps9441/ps9402/data_sheet_c78-605622.html
It has 80gb backplane connection, so to get full capabilitys of the module, you need 2 fabric modules. You would likely want 3 for N+1 redundancy.
However if you are using N7K-F132XP-15, it can make use of 230gb on the fabric...so for full capacity you would want 5 fabric modules:
http://www.cisco.com/en/US/prod/collateral/switches/ps9441/ps9402/data_sheet_c78-605622.html
Overall just check the datasheet for the modules you are using and by looking at switch fabric interface speed you should be able to plan out the number of fabrics you'll need for your cards.
Hope that helps
Chad
Similar Messages
-
Nexus 7009 does not show the N7K-F248XP-25 modules ethernet ports n sh run
Hi everyone,
I have a question...
I going to install two Nexus 7009 with three N7K-F248XP-25 modules on each one, I am planning to create 3 VDC, but at the initial configuration the system does not show the Ethernet ports of these modules, even with the show inventory and show module I can see that the modules are recognized and its status is OK. There is something that I have to do before start to configure these modules...? enable some feature or license in order to see the ports with show running CLI...?You can enable F1, F2, M1, M1XL and M2XL Series modules. There are no restrictions on the type of mix allowed for the system module-type command. The system module-type command allows a mix of F1, F2, M1, M1XL, and M2XL Series modules in the VDC.
Note The limit-resource module-type command controls the restrictions on the module-types that can be mixed in the VDC.
Note Use the system module-type f2 command to allow F2E Series modules into a VDC. The ports from F2 and F2E Series modules can be allocated like any other ports.
Note The modules that you do not enable must not be powered on after you configure this feature and enter yes. An error message will force you to manually disable these modules before proceeding. This prevents major disruption and service issues within a VDC.
The no form of this command resets the configuration mode to allow all modules.
hope this helps -
N7K - powered-dn module status
Hi guys,
Suddenly, one of the modules under 7K switch gave red alarm.
Following are the show module:
#show module
Mod Ports Module-Type Model Status
4 0 10 Gbps Ethernet Module powered-dn
Mod Power-Status Reason
4 powered-dn Unable to power up card (Power_OK not set)
Mod Sw Hw
1 6.2(6) 3.0
3 6.2(6) 1.0
Any common issue for that?
Regards.Hi,
Please try this.
1. Set on config t the diagnostic bootup level complete
2. Reseat module 4
3. show diagnostic result module 4
4. show module
If you still face the same issue after reseating it then RMA the module. Also check the available power on the switch and the minimum version required for the module to run fine. -
CSCtq89240 - Packets destined to the VDC MAC may be dropped by F1 module on N7K
Even thougth If we configure the physical mac addresses for the SVI interfaces, the packets are not reaching the destination for some vlans
Symptom:
On the n7k packets destined to the VDC MAC may be dropped when received on a F1 module.
Condition:
N7k with F1 module. Packets destined to the VDC MAC will be dropped under the following conditions:
- no SVI present or admin down
- packets received on the F1 module
Likely scenarios to see this condition include:
- transparent firewall bridging
- hair pinning traffic
- L2 load balancers
Workaround:
Configure the SVI(s) with a user-configured mac address rather than using the default VDC MAC.
This problem is isolated to the F1 module regardless of the NXOS version of code.
Are the HSRP/VRRP/GLBP virtual MAC addresses also inserted into the RMM table?
1) If yes, will we have same impact and drop packets if bridged through the FW (when packets arrive on F1 port that does not have the SVI)
No HSRP/VRRP/GLBP are not inserted in RMM. You will not have this issue for any other macs other than svi macs.
2) If HSRP vMAC is not in the RMM table, how does the F1 module know the packet has to be routed?
It is through mac table. G bit set will indicate routing has to be done. -
Enabling FCoE on N7K-F132XP-15
I ran into a problem not being able to license FCoE on N7K-F132XP-15 module. I have the license file installed properly, but still getting "
ERROR: Cannot obtain license, line card is not supported". It seems the problem is with version of HW on this particular module 1.0. Anyone has experience with this ?
switch(config)# show module
Mod Ports Module-Type Model Status
1 32 10 Gbps Ethernet Module N7K-M132XP-12 ok
2 32 1/10 Gbps Ethernet Module N7K-F132XP-15 ok
5 0 Supervisor module-1X N7K-SUP1 active *
Mod Sw Hw
1 6.0(4) 1.8
2 6.0(4) 1.0
5 6.0(4) 1.4
Mod MAC-Address(es) Serial-Num
1 d0-d0-fd-f1-5d-00 to d0-d0-fd-f1-5d-24 JAF1429CJCR
2 f8-66-f2-e4-d5-4c to f8-66-f2-e4-d5-90 JAF1704BFTD
5 00-24-f7-1d-c3-08 to 00-24-f7-1d-c3-10 JAF1317BDBF
Mod Online Diag Status
1 Pass
2 Pass
==================================================================================
switch(config)# show license usage
Feature Ins Lic Status Expiry Date Comments
Count
MPLS_PKG No - Unused -
STORAGE-ENT No - Unused -
ENTERPRISE_PKG No - Unused -
FCOE-N7K-F132XP Yes 1 Unused 30 Jan 2014 -
ENHANCED_LAYER2_PKG No - Unused -
SCALABLE_SERVICES_PKG No - Unused -
TRANSPORT_SERVICES_PKG No - Unused -
LAN_ADVANCED_SERVICES_PKG Yes - Unused Never license missing
LAN_ENTERPRISE_SERVICES_PKG Yes - Unused Never license missing
=======================================================================================
switch(config)# install feature-set fcoe
feature set is installed already(0x40aa0011)
switch(config)# li
license line
switch(config)# license fcoe module 2
ERROR: Cannot obtain license, line card is not supported
switch(config)#Padma, I think you solved the problem. The "license fcoe module 2 force" took affect (see output below). The "force" option is hidden, so I didn't make that guess on my own. I hope from here on the card should be able to handle FCoE configuration. If you know of any other pitfalls with this particular hardware revision, please share.
n7k# show version
Cisco Nexus Operating System (NX-OS) Software
TAC support: http://www.cisco.com/tac
Documents: http://www.cisco.com/en/US/products/ps9372/tsd_products_support_serie
s_home.html
Copyright (c) 2002-2012, Cisco Systems, Inc. All rights reserved.
The copyrights to certain works contained in this software are
owned by other third parties and used and distributed under
license. Certain components of this software are licensed under
the GNU General Public License (GPL) version 2.0 or the GNU
Lesser General Public License (LGPL) Version 2.1. A copy of each
such license is available at
http://www.opensource.org/licenses/gpl-2.0.php and
http://www.opensource.org/licenses/lgpl-2.1.php
Software
BIOS: version 3.22.0
kickstart: version 6.0(4)
system: version 6.0(4)
BIOS compile time: 02/20/10
kickstart image file is: bootflash:///n7000-s1-kickstart.6.0.4.bin
kickstart compile time: 12/25/2020 12:00:00 [06/22/2012 19:26:16]
system image file is: bootflash:///n7000-s1-dk9.6.0.4.bin
system compile time: 6/6/2012 18:00:00 [06/22/2012 21:03:20]
Hardware
cisco Nexus7000 C7010 (10 Slot) Chassis ("Supervisor module-1X")
Intel(R) Xeon(R) CPU with 8245320 kB of memory.
Processor Board ID JAF1330AHKM
Device name: n7k
bootflash: 2030616 kB
slot0: 2075246 kB (expansion flash)
Kernel uptime is 0 day(s), 1 hour(s), 36 minute(s), 46 second(s)
Last reset
Reason: Unknown
System version: 6.0(4)
Service:
plugin
Core Plugin, Ethernet Plugin
CMP (Module 5) ok
CMP Software
CMP BIOS version: 02.01.05
CMP Image version: 5.1(1) [build 5.0(0.66)]
CMP BIOS compile time: 7/13/2008 19:44:27
CMP Image compile time: 11/29/2010 12:00:00
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
n7k# attach module 2
module-2# show hardware internal dev-version
Name InstanceNum Version
Orion Fwding Driver 1 3.0
Orion Fwding Driver 2 3.0
Orion Fwding Driver 3 3.0
Orion Fwding Driver 4 3.0
Orion Fwding Driver 5 3.0
Orion Fwding Driver 6 3.0
Orion Fwding Driver 7 3.0
Orion Fwding Driver 8 3.0
Orion Fwding Driver 9 3.0
Orion Fwding Driver 10 3.0
Orion Fwding Driver 11 3.0
Orion Fwding Driver 12 3.0
Orion Fwding Driver 13 3.0
Orion Fwding Driver 14 3.0
Orion Fwding Driver 15 3.0
Orion Fwding Driver 16 3.0
PHY 1 56778642.1291
PHY 2 56778642.1291
PHY 3 56778642.1291
PHY 4 56778642.1291
PHY 5 56778642.1291
PHY 6 56778642.1291
PHY 7 56778642.1291
PHY 8 56778642.1291
PHY 9 56778642.1291
PHY 10 56778642.1291
PHY 11 56778642.1291
PHY 12 56778642.1291
PHY 13 56778642.1291
PHY 14 56778642.1291
PHY 15 56778642.1291
PHY 16 56778642.1291
Santa-Cruz-Module 1 0.4
Santa-Cruz-Module 2 0.4
Falcon 1 2.0
IO FPGA 1 0.045
PM FPGA 1 1.001
BIOS version v1.10.17(04/25/11)
Alternate BIOS version v1.10.17(04/25/11)
module-2#
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
n7k(config)# license fcoe module 2
ERROR: Cannot obtain license, line card is not supported
n7k(config)# license fcoe module 2 force
n7k(config)# show license usage
Feature Ins Lic Status Expiry Date Comments
Count
MPLS_PKG No - Unused -
STORAGE-ENT No - Unused Grace 119D 23H
ENTERPRISE_PKG No - Unused Grace 119D 22H
FCOE-N7K-F132XP No 0 Rsrved Grace 81D 3H
ENHANCED_LAYER2_PKG Yes - In use Never license missing
SCALABLE_SERVICES_PKG No - Unused -
TRANSPORT_SERVICES_PKG Yes - Unused Never license missing
LAN_ADVANCED_SERVICES_PKG Yes - In use Never license missing
LAN_ENTERPRISE_SERVICES_PKG Yes - Unused Never license missing -
Ciao,
in my previous post I understand that this linecard will be officially released on 18th ... and today I discovered something new in the DS published.
"This extremely comprehensive set of Layer 2 and Layer 3 functions makes this module ideal for data center networks, where density, performance, and continuous system operation are critical."
Performance
• 720-mpps Layer 2 and Layer 3 forwarding capacity for both IPv4 and IPv6 packets
The DS is here:
http://www.cisco.com/en/US/prod/collateral/switches/ps9441/ps9402/data_sheet_c78-685394.html
is this new linecard N7K-F248XP-25 a L2/L3 like the M series???
And, according to the Dynamic Configuration Tool it's stated:
"A separate VDC is needed when deploying the N7K-F248XP-25 modules in a chassis that also contains other families of modules (i.e. N7K-M1xxx and N7K-F1xxx).The VDC feature is enabled by the N7K-ADV1K9 license. A separate VDC is NOT required when the chassis contains only N7K-F248XP-25 modules."
And also NX-OS Version 6 required ...
Any ideas??
Ciao e grazie!
LucianoHi Robert,
The F2 module is L2 and L3 capable. It is quite a step up from F1 as it has no L3 capabilites, plus adding FEX to the F2 is a great improvement. As far as F2 vs M1, the M1 still has larger L3 tables and can hold more routes in hardware as well as run OTV. So the two types of modules are for different locations in your data center. M1 is a great fit for your routing edge due to this.
Lucinao,
For fabric 2 on 7010 and 7018 you must have NX-OS 6.
As far as the new VDC requirement for F2. Since the Nexus 7000s modules all have their own forwarding engines they must all run in a compatible mode. Think of it like mixing a 6500 with sup2 and a module with a DFC3...you can't do it.
So instead of just saying your chassis can only contain F2 or F1/M1 we are able to seperate the "generations" up by VDCs within the same chassis.
Chad -
I got the below error message when I config private vlan on N7K with F2 module
Error: while enabling/disabling service: private-vlan, err: Private-vlan is not allowed in F2 VDC (0x40e4005d)
Any one know about it?user8750011 wrote:
Hi - I been through best practice for deploying coherence in production but could not find one related to this.
My project has high bandwidth requirement between coherence cluster nodes, resulting an app architecture to setup private vlan inteface for application to listen on, for cluster's internal communication and another interface to face production traffic. Wondering if anyone has done this type of setup and success / failure stories.
Also interested to know how to configure traffic from production interface to application's interface ( considering i have 2 bonded interface within one box, one for production, another for high bandwidth private vlan where application will listen). These are running RHEL.
Thanks in advance for your help :).
-R.
Edited by: user8750011 on Feb 23, 2012 4:19 PMHi R,
This is a usual practice to have 2 NICs for security reasons seperating the internal and external traffic. AFAIU you question, you can configure the NIC to be used for Coherence using the property "tangosol.coherence.localhost". This would ensure that Coherence uses this NIC for communication and the other NIC can be used for other purposes.
Hope this helps!
Cheers,
NJ -
Cisco nexus 7706 Module x not responding... resetting
Hello every body,
we have in our data center 2 switches 7706 running NX-OS version 6.2(6a). One of them has notified that module 1 was not responding and rebooting it.
2015 Mar 22 14:28:55 N7K-1 %MODULE-2-MOD_NOT_ALIVE: Module 1 not responding... resetting (Serial number: xxxx)
2015 Mar 22 14:29:13 N7K-1 %PLATFORM-2-MOD_DETECT: Module 1 detected (Serial number xxxx) Module-Type 1/10 Gbps Ethernet Module Model N77-F348XP-23
2015 Mar 22 14:29:13 N7K-1 %PLATFORM-2-MOD_PWRUP: Module 1 powered up (Serial number xxxx)
2015 Mar 22 14:29:13 N7K-1 %PLATFORM-5-MOD_STATUS: Module 1 current-status is MOD_STATUS_POWERED_UP
2015 Mar 22 14:30:50 N7K-1 %BIOS_DAEMON-SLOT1-5-BIOS_DAEMON_LC_PRI_BOOT: System booted from Primary BIOS Flash
2015 Mar 22 14:32:09 N7K-1 %VDC_MGR-5-VDC_STATE_CHANGE: vdc 1 state changed to updating
2015 Mar 22 14:32:09 N7K-1 %VDC_MGR-5-VDC_STATE_CHANGE: vdc 1 state changed to active
2015 Mar 22 14:32:33 N7K-1 %PLATFORM-5-MOD_STATUS: Module 1 current-status is MOD_STATUS_ONLINE/OK
2015 Mar 22 14:32:33 N7K-1 %MODULE-5-MOD_OK: Module 1 is online (Serial number: xxxx)
2015 Mar 22 14:32:33 N7K-1 %SYSMGR-SLOT1-5-MODULE_ONLINE: System Manager has received notification of local module becoming online.
Fiew months ago we have the same symptom with module 6 instead of 1.
Note that the VPC peer-link is connected over 2x10G interfaces on each of these 2 modules.
Is there any known issue with this NX-OS version 6.2(6a)?Hi,
I see that the module reloaded to recover from a EOBC heartbeat failure.
108) At 955385 usecs after Sun Mar 22 14:28:55 2015
Sequence initiation: LC removal
109) At 955209 usecs after Sun Mar 22 14:28:55 2015
Sending MTS_OPC_LC_STATUS_CHANGE to Registry
110) At 955206 usecs after Sun Mar 22 14:28:55 2015
Received MTS_OPC_LCP_NOT_RESPONDING from Line card manager
111) At 955148 usecs after Sun Mar 22 14:28:55 2015
Sending MTS_OPC_LCP_NOT_RESPONDING to Line card manager
112) At 458025 usecs after Sun Mar 22 14:28:19 2015
Warning on ports: 1-0 due to EOBC heartbeat failure in device 10
Device error code: 0xc0a0
113) At 457788 usecs after Sun Mar 22 14:28:19 2015
Received MTS_OPC_LC_RUNTIME_DIAG_FROM_SUP from EOBC monitor kernel SAP
114) At 435569 usecs after Sun Mar 22 14:28:19 2015
Warning on ports: 1-0 due to EOBC heartbeat failure in device 10
Device error code: 0xc0a0
115) At 435312 usecs after Sun Mar 22 14:28:19 2015
Received MTS_OPC_LC_RUNTIME_DIAG_FROM_SUP from EOBC monitor kernel SAP
N7K-1# show module internal exceptionlog module 1
********* Exception info for module 1 ********
exception information --- exception instance 1 ----
Module Slot Number: 1
Device Id : 10
Device Name : eobc
Device Errorcode : 0xc0a0314f
Device ID : 10 (0x0a)
Device Instance : 03 (0x03)
Dev Type (HW/SW) : 01 (0x01)
ErrNum (devInfo) : 79 (0x4f)
System Errorcode : 0x4042004e EOBC heartbeat failure
Error Type : Warning
PhyPortLayer : Ethernet
Port(s) Affected :
DSAP : 0 (0x0)
UUID : 0 (0x0)
Time : Sun Mar 22 14:28:19 2015
(Ticks: 550EC373 jiffies)
exception information --- exception instance 2 ----
Module Slot Number: 1
Device Id : 10
Device Name : eobc
Device Errorcode : 0xc0a0314d
Device ID : 10 (0x0a)
Device Instance : 03 (0x03)
Dev Type (HW/SW) : 01 (0x01)
ErrNum (devInfo) : 77 (0x4d)
System Errorcode : 0x4042004e EOBC heartbeat failure
Error Type : Warning
PhyPortLayer : Ethernet
Port(s) Affected :
DSAP : 0 (0x0)
UUID : 0 (0x0)
Time : Sun Mar 22 14:28:19 2015
(Ticks: 550EC373 jiffies)
The EOBC is Ethernet Out of Band Channel.
There are regular keepalives or 'heartbeats' going between the sup and line cards. The error messages you received indicate a heartbeat went missing between SUP and linecard.
If a single heartbeat went missing, it will be corrected automatically, however if multiple heartbeats are lost simultaneously then the line card would be reset (sup would power off and power on that slot in attempt to resolve a diagnostic issue).
So if the card is stable after that you can consider this as a one time (transient) issue.
You can also check EOBC stats to see if any error increasing.
show hardware internal eobc stats
show hardware internal eobcsw stats
show hardware internal cpu-mac eobc stats
show hardware internal cpu-mac eobc events
show hardware capacity eobc
Hope this helps.
PS : Please grade all posts which are useful.
Thanks,
Madhu. -
Nexus 7009 N7K-M2206FQ-23L 40GigE Port Configuration Problem
Hi,
I am experiencing a strange behaviour in configuring a 40GigE Link between two Nexus 7009 Eth6/1 and Eth9/2; both sides have a
N7K-M2206FQ-23L Module; I am using a QSFP-40GE-LR4 Optic on both sides. The Operting system is 6.2(6) on both sides.
After configuring the Interfaces as a Layer3 Interface and a no shutdown I get the message
Ethernet6/1 is down (Administratively down)
admin state is down, Dedicated Interface
So what is going wrong ?
Thanks in advance
Manfred
Ethernet6/1
transceiver is present
type is QSFP-40GE-LR4
name is CISCO
part number is FTL4C1QE1C-C1
revision is B
serial number is FNS18410KXL
nominal bitrate is 10300 MBit/sec per channel
Link length supported for 9/125um fiber is 10 km
cisco id is --
cisco extended id number is 176
cisco part number is 10-2848-01
cisco product id is QSFP-40GE-LR4
cisco vendor id is V01
Ethernet9/2
transceiver is present
type is QSFP-40GE-LR4
name is CISCO
part number is FTL4C1QE1C-C1
revision is B
serial number is FNS1834014K
nominal bitrate is 10300 MBit/sec per channel
Link length supported for 9/125um fiber is 10 km
cisco id is --
cisco extended id number is 176Hi,
After connecting the cable to both ports, do you see green lights on the ports?
Do the interfaces go to up and up mode at all?
HTH -
Welcome to the Solutions and Architectures Data Center & Virtualization Community
Welcome to the Solutions and Architectures Data Center & Virtualization Community. We encourage everyone to share their knowledge and start conversations related to Data Center and Virtualization Solutions and architectures.All topics are welcome, including Servers – Unified Computing, Data Center Security, Data Center Switching, Data Center Management and Automation, Storage Networking, Application Networking Services and solutions to solve business problems.
Remember, just like in the workplace, be courteous to your fellow forum participants. Please refrain from using disparaging or obscene language or posting advertisements.
Cheers,
Dan BruhnHi,
I have a question...
I going to install two Nexus 7009 with three N7K-F248XP-25 modules on each one, I am planning to create 3 VDC, but at the initial configuration the system does not show the ethernets ports of these modules, even with the show inventory and show module I can see tah the modules are recognized and its status is OK. There is something that I have to do before start to configure these modules...? enable some feature or license in order to see the ports with show running CLI...? -
Welcome to Solutions and Architectures Borderless Networks Community
Welcome to the Solutions and Architectures Borderless Networks Community. We encourage everyone to share their knowledge and start conversations related to Borderless Solutions and architectures. All topics are welcome, including Switches, Routers, Security, Wireless, Cloud and System Management, WAN Optimization and solutions to solve business problems.
Remember, just like in the workplace, be courteous to your fellow forum participants. Please refrain from using disparaging or obscene language or posting advertisements.
Cheers,
Dan BruhnHi,
I have a question...
I going to install two Nexus 7009 with three N7K-F248XP-25 modules on each one, I am planning to create 3 VDC, but at the initial configuration the system does not show the ethernets ports of these modules, even with the show inventory and show module I can see tah the modules are recognized and its status is OK. There is something that I have to do before start to configure these modules...? enable some feature or license in order to see the ports with show running CLI...? -
Welcome to the Solutions and Architectures Collaboration Community
Welcome to the Solutions and Architectures Collaboration Community. We encourage everyone to share their knowledge and start conversations related to Collaboration Solutions and architectures.All topics are welcome, including Collaboration Applications, Customer Collaboration, Telepresence, Unified Communications and solutions to solve business problems.
Remember, just like in the workplace, be courteous to your fellow forum participants. Please refrain from using disparaging or obscene language or posting advertisements.
Cheers,
Dan BruhnHi,
I have a question...
I going to install two Nexus 7009 with three N7K-F248XP-25 modules on each one, I am planning to create 3 VDC, but at the initial configuration the system does not show the ethernets ports of these modules, even with the show inventory and show module I can see tah the modules are recognized and its status is OK. There is something that I have to do before start to configure these modules...? enable some feature or license in order to see the ports with show running CLI...? -
Using 40GE ports for VPC Peer Link
Hi,
Is it possible to use the native 40GE ports on the N7K-M206FQ-23L module for the VPC Peer Link, or do you have to break these ports out into 10GE ? I have read that 10GE ports must be used for the VPC peer link.
Thanks in advance.You can use 40GE ports for VPC peer-link. No need to break those to 10G.
-
New Solutions And Architectures Community
I am pleased to announce the launch of our new Cisco Solutions and Architectures Community with sub-communities for Borderless Networks, Collaboration, Data Center & Virtualization. We encourage everyone to share their knowledge and start conversations related to network design and overall Cisco network topology.
All topics are welcome, including WAN, LAN, enterprise, service provider, data center / virtualization, wireless, security, collaboration, voice & video network design architecture and solutions to solve business problems.
The content from our pilot Network Infrastructure “Design and Architecture” community will be merged into the appropriate Solutions and Architectures sub-community.
Cheers,
DanHi,
I have a question...
I going to install two Nexus 7009 with three N7K-F248XP-25 modules on each one, I am planning to create 3 VDC, but at the initial configuration the system does not show the ethernets ports of these modules, even with the show inventory and show module I can see tah the modules are recognized and its status is OK. There is something that I have to do before start to configure these modules...? enable some feature or license in order to see the ports with show running CLI...? -
Module on N7K suddenly restarted
Hi Guys,
One of the module in cisco nexus 7010 suddenly restarted,
2014 Nov 21 11:47:39 WIB MASTER %MODULE-2-MOD_NOT_ALIVE: Module 3 not responding... resetting (Serial number: JAF1612ASPA)
2014 Nov 21 11:47:50 WIB MASTER %PLATFORM-2-MOD_DETECT: Module 3 detected (Serial number JAF1612ASPA) Module-Type 10/100/1000 Mbps Ethernet XL Module Model N7K-
M148GT-11L
2014 Nov 21 11:47:50 WIB MASTER %PLATFORM-2-MOD_PWRUP: Module 3 powered up (Serial number JAF1612ASPA)
2014 Nov 21 11:47:50 WIB MASTER %PLATFORM-5-MOD_STATUS: Module 3 current-status is MOD_STATUS_POWERED_UP
2014 Nov 21 11:50:04 WIB MASTER %PLATFORM-5-MOD_STATUS: Module 3 current-status is MOD_STATUS_ONLINE/OK
2014 Nov 21 11:50:04 WIB MASTER %MODULE-5-MOD_OK: Module 3 is online (Serial number: JAF1612ASPA)
2014 Nov 21 11:50:03 WIB MASTER %SYSMGR-SLOT3-5-MODULE_ONLINE: System Manager has received notification of local module becoming online.
2014 Nov 21 11:51:49 WIB MASTER %BIOS_DAEMON-SLOT3-5-BIOS_DAEMON_LC_PRI_BOOT: System booted from Primary BIOS Flash
Please tell me what is the root cause which made the problem occurred.
Thank you
Best regards,
heryHello Hery,
Generally, supervisor probe all the linecard by using hearbeat messages. Due to some reason supervisor did not hear any keepalive reply from any linecard then supervisor reset that linecard to recovery .
2014 Nov 21 11:47:39 WIB MASTER %MODULE-2-MOD_NOT_ALIVE: Module 3 not responding... resetting (Serial number: JAF1612ASPA)
From the above log, it looks like same thing happened in your case also . This is due to multiple reason , But most of the time EOBC congestion, EOBC drop or bad fabric connection . This could be either hardware issue or transit issue.
you can set diag level complete and reset the linecard once . After reseat (physical reseat- means remove the Linecard and insert it back) if you see any diagnostic failure or crash again then you need to replace the card otherwise its transit issue .
HTH
Regards,
VS.Suresh.
*Plz rate the usefull posts.
Maybe you are looking for
-
Video saved not in photo gallery?
I recently uploaded a video onto my phone using a sync and I can view it in the videos folder when I go into my photos, but it is not in my camara roll where I need it to be. In order to upload it I need it to be in a camara roll. I have it saved on
-
Dear gurus, Situation: we have one oraprod production DB. Daily a snapshot is made from this instance with the name orasnap. This orasnap has only 1 day life time. For this orasnap, a new DBID is generated daily using the nid utility. After this, the
-
Multiple network ports.... options?
Our Xserve has 4 ethernet ports, but our switch doesn't support the right kind of link aggregation to make use of a fat trunked 4Gb connection to our network. Is there any way I can I make use of these multiple ports to enhance or optimise network tr
-
Credit Check Per Line Item in Sales Order is Possible?
Dear All, Hope you all are doing well !!! Infact i am currently implementing OPM and SCM modules for a CSD (carbonated soft drinks) industry. They have a specific requirement on Credit Management. Please look at the Requirement Below. Credit Manageme
-
Adding A file back to dock.
I removed the applications file from the dock. How can i put it back on the dock??