N7K & N2K Connectivity

Hi All,
I would like to connect N2K with N7K for that do I need to have 10G port in dedeciated mode ?? or ports in shared mode will work ?? also If i want to connect N7K with another N7K switch do I need port  in dedicated mode ???
Please clarify...
Thanks

Information About Using a Fabric Extender with a Cisco Nexus 7000 Series Switch
You can extend the Cisco Nexus 7000 Series switch architecture by connecting up to 32 Cisco Nexus 2248 FEXs as remote I/O modules. Each FEX provides top-of-the-rack connectivity for up to 48 hosts. Each FEX becomes an extension of the parent Cisco Nexus 7000 Series switch fabric, with the FEX and the switch becoming a virtual modular system. The FEX forwards all 1-Gigabit Ethernet traffic from the hosts to the switch over 10-Gbps uplinks. Traffic flows from the switch to the FEX over the 10-Gbps uplinks and to the individual hosts over 100/1000 Mb Ethernet downlinks.
You connect a FEX to the Cisco Nexus 7000 Series switch through the 32-port M1 series Ethernet I/O modules installed in the switch. We recommend that you connect each FEX to one port in a set of four shared ports to get the fully dedicated 10-Gb bandwidth.

Similar Messages

  • N7k N2K and n5k N2K design questions

    Data Center with Dual N7K , want to add N2K for top of rack server access. I understand the model where I can set my servers up with a vPC Etherchannel to a pair of 2k with one 2k attached to each 7k. This model appears to meet all of the no single attached device rules of vPC. The question I have is how I can attach traditional server connectivity that doesn't support Etherchannel. In this model if I attach to a single 2k or team(without etherchannel) to both 2ks haven't I violated the no single attached device rule of vPC.
    I have a similar issue with the 2232 and N5k model. In order to support FCOE on a 2232, the only supported configuration is to attach the 2232 to a single 5k, in all of the design models I have seen the server is depicted with a vPC etherchannel to the two 2232s that are attached to their respective 5k. In this design if my server doesn't support an Etherchannel, and I am forced to utilize traditional teaming I have broken the no single attached device rule of VPC again.
    This no single attached device rule of vPC makes it really hard to utilize the FEX in either of these scenarios, What is the recommendation for connecting servers that don't support Etherchannel in these two models

    Hi,
    Take a look at the document Nexus 7000 Fex Supported/Not Supported Topologies and you'll see what options you currently have.
    As I mentioned, up to and including NX-OS 6.2, a single FEX can only be connected to a single Nexus 7000. This is what is shown as Figures 8, 9 and 10 in the unsupported topologies section.
    A server can be connected to two different FEX, and those two FEX could be connected to a single Nexus 7000 or two different Nexus 7000. The options are shown in Figures 6 and 7.
    Regards

  • N2K port speed set

    My N2K connected to N5K, why some ports can set the port speed, and some cann't set the port speed?
    int eth102/1/25     !!!No speed command
    (config-if)# ?
      beacon          Disable/enable the beacon for an interface
      cdp             Configure CDP interface parameters
      channel-group   Configure port channel parameters
      description     Enter description of maximum 80 characters
      inherit         Inherit a port-profile
      ip              Configure IP features
      ipv6            Configure IPv6 features
      lacp            Configure LACP parameters
      link            Configure link
      lldp            Configure Interface LLDP parameters
      logging         Configure logging for interface
      mvr-group       MVR interface config
      mvr-type        MVR interface config
      mvr-vlan        Interface MVR Config
      no              Negate a command or set its defaults
      rate-limit      Set packet per second rate limit
      service-policy  Configure service policy for an interface
      service-policy  Policy Map
      shutdown        Enable/disable an interface
      snmp            Modify SNMP interface parameters
      spanning-tree   Spanning Tree Subsystem
      switchport      Configure switchport parameters
      untagged        Default to use for untagged packets on interface
      end             Go to exec mode
      exit            Exit from command interpreter
      pop             Pop mode from stack or restore from name
      push            Push current mode to stack or save it under name
      where           Shows the cli context you are in
    (config-if)# int eth102/1/48       !!! include speed command
    (config-if)# ?
      bandwidth              Set bandwidth informational parameter
      beacon                 Disable/enable the beacon for an interface
      cdp                    Configure CDP interface parameters
      channel-group          Configure port channel parameters
      default                Set a command to its defaults
      delay                  Specify interface throughput delay
      description            Enter description of maximum 80 characters
      duplex                 Enter the port duplex mode
      fex                    Configure FEX fabric
      flowcontrol            Configure interface flowcontrol
      hardware               FEX Card type
      inherit                Inherit a port-profile
      ip                     Configure IP features
      ipv6                   Configure IPv6 features
      lacp                   Configure LACP parameters
      link                   Configure link
      lldp                   Configure Interface LLDP parameters
      load-interval          Specify interval for load calculation for an interface
      logging                Configure logging for interface
      mac                    MAC
      mac-address            Configure interface mac address
      mvr-group              MVR interface config
      mvr-type               MVR interface config
      mvr-vlan               Interface MVR Config
      negotiate              Configure link negotiation parameters
      no                     Negate a command or set its defaults
      priority-flow-control  Enable/Disable PFC
      rate-limit             Set packet per second rate limit
      service-policy         Configure service policy for an interface
      service-policy         Policy Map
      shutdown               Enable/disable an interface
      snmp                   Modify SNMP interface parameters
      spanning-tree          Spanning Tree Subsystem
      speed                  Enter the port speed
      storm-control          Configure Interface storm control
      switchport             Configure switchport parameters
      untagged               Default to use for untagged packets on interface
      vpc                    Virtual Port Channel configuration
      vtp                    Enable VTP on this interface
      end                    Go to exec mode
      exit                   Exit from command interpreter
      pop                    Pop mode from stack or restore from name
      push                   Push current mode to stack or save it under name
      where                  Shows the cli context you are in
    1,N5K version:
    Cisco Nexus Operating System (NX-OS) Software
    TAC support: http://www.cisco.com/tac
    Documents: http://www.cisco.com/en/US/products/ps9372/tsd_products_support_series_home.html
    Copyright (c) 2002-2013, Cisco Systems, Inc. All rights reserved.
    The copyrights to certain works contained herein are owned by
    other third parties and are used and distributed under license.
    Some parts of this software are covered under the GNU Public
    License. A copy of the license is available at
    http://www.gnu.org/licenses/gpl.html.
    Software
      BIOS:      version 3.6.0
      loader:    version N/A
      kickstart: version 6.0(2)N1(2)
      system:    version 6.0(2)N1(2)
      Power Sequencer Firmware:
                 Module 1: version v5.0
      Microcontroller Firmware:        version v1.0.0.2
      SFP uC:    Module 1: v1.1.0.0
      QSFP uC:   Module not detected
      BIOS compile time:       05/09/2012
      kickstart image file is: bootflash:///n5000-uk9-kickstart.6.0.2.N1.2.bin
      kickstart compile time:  3/14/2013 1:00:00 [03/14/2013 16:53:55]
      system image file is:    bootflash:///n5000-uk9.6.0.2.N1.2.bin
      system compile time:     3/14/2013 1:00:00 [03/14/2013 19:28:50]
    Hardware
      cisco Nexus 5596 Chassis ("O2 48X10GE/Modular Supervisor")
      Intel(R) Xeon(R) CPU         with 8262944 kB of memory.
    2,N5K port
    Eth102/1/1    --                 connected 101       full    1000    --        
    Eth102/1/2    --                 connected 101       full    1000    --        
    Eth102/1/3    --                 connected 101       full    1000    --        
    Eth102/1/4    --                 connected 101       full    1000    --        
    Eth102/1/5    --                 connected 101       full    1000    --        
    Eth102/1/6    --                 connected 101       full    1000    --        
    Eth102/1/7    --                 connected 101       full    1000    --        
    Eth102/1/8    --                 connected 101       full    1000    --        
    Eth102/1/9    --                 connected 101       full    1000    --        
    Eth102/1/10   --                 connected 101       full    1000    --        
    Eth102/1/11   --                 connected 101       full    1000    --        
    Eth102/1/12   --                 connected 101       full    1000    --        
    Eth102/1/13   --                 connected 101       full    1000    --        
    Eth102/1/14   --                 connected 101       full    1000    --        
    Eth102/1/15   --                 connected 104       full    1000    --        
    Eth102/1/16   --                 connected 104       full    1000    --        
    Eth102/1/17   --                 connected 104       full    1000    --        
    Eth102/1/18   --                 connected 104       full    1000    --        
    Eth102/1/19   --                 connected 104       full    1000    --        
    Eth102/1/20   --                 connected 104       full    1000    --        
    Eth102/1/21   --                 connected 104       full    1000    --        
    Eth102/1/22   --                 connected 104       full    1000    --        
    Eth102/1/23   --                 connected 104       full    1000    --        
    Eth102/1/24   --                 connected 104       full    1000    --        
    Eth102/1/25   --                 notconnec 102       auto    auto    --        
    Eth102/1/26   --                 notconnec 102       auto    auto    --        
    Eth102/1/27   --                 connected 106       full    1000    --        
    Eth102/1/28   --                 connected 106       full    1000    --        
    Eth102/1/29   --                 connected 104       full    1000    --        
    Eth102/1/30   --                 connected 104       full    1000    --        
    Eth102/1/31   --                 connected 104       full    1000    --        
    Eth102/1/32   --                 connected 104       full    1000    --        
    Eth102/1/33   --                 connected 104       full    1000    --        
    Eth102/1/34   --                 connected 104       full    1000    --        
    Eth102/1/35   --                 connected 104       full    1000    --        
    Eth102/1/36   --                 connected 104       full    1000    --        
    Eth102/1/37   --                 connected 104       full    1000    --        
    Eth102/1/38   --                 connected 104       full    1000    --        
    Eth102/1/39   --                 notconnec 1         auto    auto    --        
    Eth102/1/40   --                 notconnec 1         auto    auto    --        
    Eth102/1/41   --                 notconnec 1         auto    auto    --        
    Eth102/1/42   --                 notconnec 1         auto    auto    --        
    Eth102/1/43   --                 notconnec 1         auto    auto    --        
    Eth102/1/44   --                 notconnec 1         auto    auto    --        
    Eth102/1/45   --                 notconnec 1         auto    auto    --        
    Eth102/1/46   --                 notconnec 1         auto    auto    --        
    Eth102/1/47   --                 notconnec 1         auto    auto    --        
    Eth102/1/48   ZTC-Switch-48      connected 105       full    100     -- 
    3,Fex
    show fex 102 det
    FEX: 102 Description: AO4-N2K-FEX102   state: Online
      FEX version: 6.0(2)N1(2) [Switch version: 6.0(2)N1(2)]
      FEX Interim version: 6.0(2)N1(2)
      Switch Interim version: 6.0(2)N1(2)
      Extender Serial: FOX1742G09B
      Extender Model: N2K-C2248TP-E-1GE,  Part No: 73-13671-02
      Card Id: 149, Mac Addr: 64:e9:50:16:08:02, Num Macs: 64
      Module Sw Gen: 21  [Switch Sw Gen: 21]
      post level: complete
      Pinning-mode: static    Max-links: 1
      Fabric port for control traffic: Eth1/3
      FCoE Admin: false
      FCoE Oper: true
      FCoE FEX AA Configured: false
      Fabric interface state:
        Po102 - Interface Up. State: Active
        Eth1/1 - Interface Up. State: Active
        Eth1/2 - Interface Up. State: Active
        Eth1/3 - Interface Up. State: Active
        Eth1/4 - Interface Up. State: Active
      Fex Port        State  Fabric Port
           Eth102/1/1    Up       Po102
           Eth102/1/2    Up       Po102
           Eth102/1/3    Up       Po102
           Eth102/1/4    Up       Po102
           Eth102/1/5    Up       Po102
           Eth102/1/6    Up       Po102
           Eth102/1/7    Up       Po102
           Eth102/1/8    Up       Po102
           Eth102/1/9    Up       Po102
          Eth102/1/10    Up       Po102
          Eth102/1/11    Up       Po102
          Eth102/1/12    Up       Po102
          Eth102/1/13    Up       Po102
          Eth102/1/14    Up       Po102
          Eth102/1/15    Up       Po102
          Eth102/1/16    Up       Po102

    show run int eth102/1/25 all
    !Command: show running-config interface Ethernet102/1/25 all
    !Time: Tue Apr 14 14:33:38 2009
    version 6.0(2)N1(2)
    interface Ethernet102/1/25
      no description
      lacp port-priority 32768
      lacp rate normal
      priority-flow-control mode auto
      lldp transmit
      lldp receive
      no switchport block unicast
      no switchport block multicast
      no hardware multicast hw-hash
      no hardware vethernet mac filtering per-vlan
      cdp enable
      switchport
      switchport mode access
      no switchport dot1q ethertype
      no switchport priority extend
      switchport access vlan 102
      spanning-tree port-priority 128
      spanning-tree cost auto
      spanning-tree link-type auto
      spanning-tree port type edge
      spanning-tree bpduguard enable
      no spanning-tree bpdufilter
      speed auto
      duplex auto
      flowcontrol receive off
      flowcontrol send on
      no link debounce
      no beacon
      delay 1
      snmp trap link-status
      logging event port link-status default
      logging event port trunk-status default
      mdix auto
      storm-control broadcast level 100.00
      storm-control multicast level 100.00
      storm-control unicast level 100.00
      no shutdown lan
      load-interval counter 1 30
      load-interval counter 2 300
      no load-interval counter 3
      medium broadcast
      channel-group 2025 mode active
      no shutdown
    show run int eth102/1/48 all
    !Command: show running-config interface Ethernet102/1/48 all
    !Time: Tue Apr 14 14:35:08 2009
    version 6.0(2)N1(2)
    interface Ethernet102/1/48
      description ZTC-Switch-48
      lacp port-priority 32768
      lacp rate normal
      priority-flow-control mode auto
      lldp transmit
      lldp receive
      no switchport block unicast
      no switchport block multicast
      no hardware multicast hw-hash
      no hardware vethernet mac filtering per-vlan
      cdp enable
      switchport
      switchport mode access
      no switchport dot1q ethertype
      no switchport priority extend
      switchport access vlan 105
      spanning-tree port-priority 128
      spanning-tree cost auto
      spanning-tree link-type auto
      spanning-tree port type edge
      spanning-tree bpduguard enable
      no spanning-tree bpdufilter
      speed auto
      duplex auto
      flowcontrol receive off
      flowcontrol send on
      no link debounce
      no beacon
      delay 1
      snmp trap link-status
      logging event port link-status default
      logging event port trunk-status default
      mdix auto
      storm-control broadcast level 100.00
      storm-control multicast level 100.00
      storm-control unicast level 100.00
      no shutdown lan
      load-interval counter 1 30
      load-interval counter 2 300
      no load-interval counter 3
      medium broadcast
      no shutdown
    Ports are connected, there is no relationship with the speed option, such as port 102/1/1 is connected, but no speed option, port 102/1/47 is notconnected, there speed options.
    show int eth102/1/1
    Ethernet102/1/1 is up
      Belongs to Po2001
      Hardware: 100/1000 Ethernet, address: 64e9.5016.0802 (bia 64e9.5016.0802)
      MTU 1500 bytes, BW 1000000 Kbit, DLY 10 usec
      reliability 255/255, txload 1/255, rxload 1/255
      Encapsulation ARPA
      Port mode is access
      full-duplex, 1000 Mb/s
      Beacon is turned off
      Input flow-control is off, output flow-control is on
      Switchport monitor is off
      EtherType is 0x8100
      Last link flapped 1d02h
    int eth102/1/1
    (config-if)# ?
      beacon          Disable/enable the beacon for an interface
      cdp             Configure CDP interface parameters
      channel-group   Configure port channel parameters
      description     Enter description of maximum 80 characters
      inherit         Inherit a port-profile
      ip              Configure IP features
      ipv6            Configure IPv6 features
      lacp            Configure LACP parameters
      link            Configure link
      lldp            Configure Interface LLDP parameters
      logging         Configure logging for interface
      mvr-group       MVR interface config
      mvr-type        MVR interface config
      mvr-vlan        Interface MVR Config
      no              Negate a command or set its defaults
      rate-limit      Set packet per second rate limit
      service-policy  Configure service policy for an interface
      service-policy  Policy Map
      shutdown        Enable/disable an interface
      snmp            Modify SNMP interface parameters
      spanning-tree   Spanning Tree Subsystem
      switchport      Configure switchport parameters
      untagged        Default to use for untagged packets on interface
      end             Go to exec mode
      exit            Exit from command interpreter
      pop             Pop mode from stack or restore from name
      push            Push current mode to stack or save it under name
      where           Shows the cli context you are in
    show int eth102/1/47
    Ethernet102/1/47 is down (Link not connected)
      Hardware: 100/1000 Ethernet, address: 64e9.5016.0830 (bia 64e9.5016.0830)
      MTU 1500 bytes, BW 0 Kbit, DLY 10 usec
      reliability 255/255, txload 1/255, rxload 1/255
      Encapsulation ARPA
      Port mode is access
      auto-duplex, auto-speed
      Beacon is turned off
      Input flow-control is off, output flow-control is on
      Switchport monitor is off
      EtherType is 0x8100
    int eth102/1/47
    (config-if)# ?
      bandwidth              Set bandwidth informational parameter
      beacon                 Disable/enable the beacon for an interface
      cdp                    Configure CDP interface parameters
      channel-group          Configure port channel parameters
      default                Set a command to its defaults
      delay                  Specify interface throughput delay
      description            Enter description of maximum 80 characters
      duplex                 Enter the port duplex mode
      fex                    Configure FEX fabric
      flowcontrol            Configure interface flowcontrol
      hardware               FEX Card type
      inherit                Inherit a port-profile
      ip                     Configure IP features
      ipv6                   Configure IPv6 features
      lacp                   Configure LACP parameters
      link                   Configure link
      lldp                   Configure Interface LLDP parameters
      load-interval          Specify interval for load calculation for an interface
      logging                Configure logging for interface
      mac                    MAC
      mac-address            Configure interface mac address
      mvr-group              MVR interface config
      mvr-type               MVR interface config
      mvr-vlan               Interface MVR Config
      negotiate              Configure link negotiation parameters
      no                     Negate a command or set its defaults
      priority-flow-control  Enable/Disable PFC
      rate-limit             Set packet per second rate limit
      service-policy         Configure service policy for an interface
      service-policy         Policy Map
      shutdown               Enable/disable an interface
      snmp                   Modify SNMP interface parameters
      spanning-tree          Spanning Tree Subsystem
      speed                  Enter the port speed
      storm-control          Configure Interface storm control
      switchport             Configure switchport parameters
      untagged               Default to use for untagged packets on interface
      vpc                    Virtual Port Channel configuration
      vtp                    Enable VTP on this interface
      end                    Go to exec mode
      exit                   Exit from command interpreter
      pop                    Pop mode from stack or restore from name
      push                   Push current mode to stack or save it under name
      where                  Shows the cli context you are in

  • Adding N2K to existing infrastructure

    Hi,
    I have to add a pair of N2Ks to Existing N5Ks. There is already a pair of N2Ks attached to N5Ks. 
    What are the steps required to perform this task ? Also, can I combine FETs with SFPs for N2K connection on a single switch. 
    Do I need any downtime for the already connected N2K and N5K or any service disruption during this activity?
    Thanks

    Hi,
    What are the steps required to perform this task ? Rack the 2ks and run the cables to 5ks and plug in the SFP+s or FETs on both sides. If the link comes up create your VPC config and than do a "sh fex" if all configured correctly you should see the new FEXs online.
    can I combine FETs with SFPs for N2K connection on a single switch. 
    No, use FETs or 10Gig SFP+.  Every 2k comes 4 FETs in the box so that should be enough to connect the FEX to both 5ks using 10Gigs.
    Do I need any downtime for the already connected N2K and N5K or any service disruption during this activity?
    No, no need for any downtime. Your old FEXs should be untouched.
    HTH

  • Nexus Queries

    Hi,
        I have following Queries in the Nexus. Please help me with information.
    •1.       M1, M2 & F2 cards in N7K, which one will be used for Routing & Switching?
    •2.       vPC primary Nexus 7K & vPC secondary Nexus 5K. It will support? & why?
    •3.       Port-channel between N7K & N2K mandatory to communicate hosts connected  to N2Ks?
    •4.       By default why VTP mode is Transparent in Nexus Switches? But in IOS by default Server mode.
    Thanks
    Venkat

    When configuring a single sided vPC both switches must be the same model, ie a pair of N5Ks or a pair of N7Ks. With vPC each switch retains its own control plane and data plane. Control messages and data frames flow between the active and standby switches via the peer link.
    With double sided vPC you can have a pair of N5Ks and a pair of N7Ks. See the link below for details:
    https://supportforums.cisco.com/docs/DOC-20836

  • Fabricpath / HSRPv2

    Hello,
    i have a pair of N7k's connected to each other by fabricpath. Southbound the n7k's are connected to n5k's, also connected by fabricpath. Northbound the n7k's are connected to the ip core routers. The connection to the IP core router is an SVI100 (vlan mode ce) that is attached to a port-channel
    I have created a fabricpath vlan 101 on all the switches and the SVI is on both n7k's and i'm running HSRPv2 between the n7k's. The left n7k is the active node.
    n7k (left)
    interface Vlan101
      no shutdown
      vrf member public
      no ip redirects
      ip address 1.1.1.2/26
      hsrp version 2
      hsrp 101 
        preempt 
        priority 105
        ip 1.1.1.1
    interface port-channel1
      description peer-link to n7k right
      switchport mode fabricpath
      bandwidth inherit
      vpc peer-link
    n7k (right)
    interface Vlan101
      no shutdown
      vrf member public
      no ip redirects
      ip address 1.1.1.3/26
      hsrp version 2
      hsrp 101 
        ip 1.1.1.1
    On both n7k's the arp table is filled. Only from the n7k left i can't ping the 1.1.1.3 with a source ip address from vlan 100 (uplink ce vlan). When i don't use the source vlan 100 ip address, the ping works.
    Why can't i ping the ip address 1.1.1.3 from the n7k left when i'm using the source ip address from vlan 100?
    kind regards,
    Pascal Lacroix

    Hi,
    Yes this is possible, and indeed we're doing something very similar to what you're proposing.
    We have Nexus 7K spine switches, which are also the L3 boundary running vPC+, and these are connected via standard IEEE 802.1Q trunks to standard STP capable switches.
    The area to be mindful of is that a FabricPath CE (Classic Ethernet) ports behave as if running STP "root guard" and as such will become disabled if they receive a superior STP BPDU e.g., one with a lower priority. You'll see a SYSLOG message along the lines of %STP-2-L2GW_BACKBONE_BLOCK if this occurs.
    There's more detail on this in the FabricPath Versus Classical Ethernet Networks section of the Cisco Nexus 5000 Series NX-OS Operations Guide.
    The other document on FP that would be worth looking through is Mark Stinnette's Quick Start Guide :: FabricPath. This is a cook book style configuration guide, and some of the "recipes" shown deal with exactly this and need to ensure the FP domain is the STP root.
    Regards

  • N5K - single point of failure?

    When both N5K (running 4.2(1)N1(1b) are powered down, if one of them fails to power up, all N2K connected to the two N5K fails to power up. This scenario could happen in situation where there is a power maintainence when both N5K are brought down. It looks like it is related to the below. Beginning with Cisco NX-OS Release 5.0(2)N1(1), you can configure the Cisco Nexus 5000 Series switch to restore vPC services when its peer switch fails to come online by using the reload restore command. You must save this setting in the startup configuration. On reload, Cisco NX-OS Release 5.0(2)N1(1) starts a user-configurable timer (the default is 240 seconds). If the peer-link port comes up physically or the peer-keepalive is functional, the timer is stopped. Can anyone confirm that ? Thanks Eng Wee

    This design option works
    However keep in mind that your design has single point of failure in the nexus side if you need it end to end redundant you need to consider adding a second switch to the topology
    Hope this help
    Sent from Cisco Technical Support iPad App

  • VPC issue with HP server

    Hi
    We are trying to set up a vPC between a HP server and two N2K (connected to Nexus 7009).
    vPC does not work if we plug HP server NIC1 and NIC2 into the same port on both N2Ks like Eth 101/1/1
    vPc works when we if we plug HP serve NIC1 and NIC2 into diffrent port on both N2Ks like N2K1 port Eth101/1/1 and N2K2 port Eth 101/1/32
    Please advise
    Regards,
    Nomi

    Please show vpc config and interface config of switch

  • Nexus 7004 with N2K-B22HP-P FEX won't connect

    Hello
    I'm trying to connect an HP Blade server with an N2K-B22HP-P to our Nexus 7004 but it stays in de download mode.
    # sh fex
      FEX         FEX           FEX                       FEX
    Number    Description      State            Model            Serial
    116        FEX0116        Image Download         N2K-B22HP-P   FOCxxxxxxxx
    # sh fex detail
    FEX: 116 Description: FEX0116   state: Image Download
      FEX version: 5.2(1)N1(1a) [Switch version: 6.1(4)]
      FEX Interim version: 5.2(1)N1(1a)
      Switch Interim version: 6.1(4)
      Module Sw Gen: 12594  [Switch Sw Gen: 21]
    pinning-mode: static    Max-links: 1
      Fabric port for control traffic: Eth3/44
      Fabric interface state:
        Po116 - Interface Up. State: Active
        Eth3/44 - Interface Up. State: Active
      Fex Port        State  Fabric Port
    Logs:
    08/07/2013 18:04:24.424401: Requesting satellite to download image
    08/07/2013 18:04:46.442690: Module register received
    08/07/2013 18:04:46.443233: Registration response sent
    08/07/2013 18:04:46.443516: Requesting satellite to download image
    08/07/2013 18:05:10.475657: Module register received
    08/07/2013 18:05:10.476109: Registration response sent
    08/07/2013 18:05:10.476390: Requesting satellite to download image
    08/07/2013 18:05:36.703639: Module register received
    08/07/2013 18:05:36.704118: Registration response sent
    08/07/2013 18:05:36.704434: Requesting satellite to download image
    08/07/2013 18:06:04.741774: Module register received
    08/07/2013 18:06:04.742505: Registration response sent
    08/07/2013 18:06:04.742628: Requesting satellite to download image

    Hi Martin,
    At this point in time the N2K-B22-HP FEX is not supported with the Nexus 7000 series switches as the parent switch. If you look at Table 2 in the Cisco Nexus B22 Blade Fabric Extender Data Sheet you'll see it only lists the following:
    Cisco Nexus parent switch model or line card
    Cisco Nexus 5010 or 5020 Switch for Cisco Nexus B22HP and B22F
    Cisco Nexus 5548P Switch
    Cisco Nexus 5548UP Switch
    Cisco Nexus 5596UP Switch
    Cisco Nexus 6001 Switch
    Cisco Nexus 6004 Switch
    Regards

  • Can you Connect Cisco switch modules for to N2K?

    I have not seen anything about connecting Cisco Switch modules for Blade Chassis to fex.  Does anybody now if you can do that?
    thank you.

    thank you Lucien.
    I think you got a right name for N2Ks, a NIC card extender.  In my opion N2K should be able to support Blade switches. Not every company has just rack mount servers, most enviroment is mixed. In my case, I run out ports on N5K, but plenty available on N2K.  I want add two more blade centers with gig switch modules in them. now I have to buy a N5K!!!.  I'm sure Cisco can make N2K to support switches too.

  • LACP suspended between N7K and N2K

    Hi
    we have a creation trouble between N7K and N2K on port-channel, the port-channel is suspended because LACP receive PDUs

    With FEX you use don't use the mode active. 
    Interface eth5/33
      switchport mode fex-fabric
      channel-group 70
    The FEX uses a "Fabric" header on the link, and doesn't require LACP.  You can use LACP on any host ports on the FEX, just not on the fabric links.

  • Multicast clustering IBM servers with N7K and 2k

         i have two severs IBM are working as a cluster and  connected to Fiber fabric extender 2K  using VPC as per attached diagram
         two IBM server are woriking fine  for network connectivity with N2k but the servers have a multicast named ( power HA 7.1) to work as acluster
          but i tried to configue multicat in N7K and N2k to server working as acluster but the servers are not working
         please advice me about the configuration in N7K and N2k  to working IBM servers as a cluster .

    One option is the IGMP querier:
    config t
      ip igmp snooping
      vlan 2
    switch(config-vlan-config)# ip igmp snooping querier 10.0.10.253
              (or a good source address of the interface)
    The other option is run PIM on the VLAN interface:
    feature pim 
    vlan 2
      ip pim sparse-mode
    Both has the same purpose: combined with IGMP snooping, the L3 interface will flood the VLAN with IGMP queries that traverse the inter-switch links. As a result, the inter-switch links will be included in the snooping port list. In turn,
    packets destined to 228.5.10.5 will be sent out the inter-switch link and reach the other server.
    Without the IGMP queries, 228.5.10.5 packets will not be sent from one switch to the other as it is not in the 224.0.0.0/24 range.

  • Nexus 7000 w/ 2000 FEX - Interface Status When N7K has power issues

    I have multiple nexus 2Ks connected to two N7Ks with my servers connecting to multiple N2Ks accordingly with dual NIC failover capability.
    What happens, or what state do the N2K interfaces go into if one of my N7K's looses power given the N2K is effectivly still receiving power?

    Hi Ans,
    You are rigth, I have defaulted againt the port, now configured with switchport mode FEX, and now the FET-10G is validated
    NX7K-1-VDC-3T-S1-L2FP(config-if)#  description FEX-101
    NX7K-1-VDC-3T-S1-L2FP(config-if)#   switchport
    NX7K-1-VDC-3T-S1-L2FP(config-if)#   switchport mode fex-fabric
    NX7K-1-VDC-3T-S1-L2FP(config-if)#   fex associate 101
    NX7K-1-VDC-3T-S1-L2FP(config-if)#   medium p2p
    NX7K-1-VDC-3T-S1-L2FP(config-if)#   channel-group 101
    NX7K-1-VDC-3T-S1-L2FP(config-if)#   no shutdown
    NX7K-1-VDC-3T-S1-L2FP(config-if)#
    NX7K-1-VDC-3T-S1-L2FP(config-if)# sh int e7/33 status
    Port             Name            Status    Vlan      Duplex  Speed   Type
    Eth7/33          FEX-101         notconnec 1         auto    auto    Fabric Exte
    NX7K-1-VDC-3T-S1-L2FP(config-if)#
    Thanks for your help, and have a nice weekend.
    Atte,
    EF

  • WAN Router Connection to Data Center

    We have a WAN router that needs to connect to our Data Center network.  The Data Center consists of two N7K core switches, with a pair of N5K switches as aggregation, and each N5K has twelve N2K fabric extenders.  The N2Ks are single-homed to the N5Ks.  The N5Ks are vPC connected to the N7Ks.
    We would like to attach the WAN router to both N7K switches in the Data Center.  The N7K switches only have 10G ports in them, so we can't terminate the WAN router directly to the N7Ks.
    I was considering creating one dedicated VLAN on each N7K, and assigning an SVI to each VLAN, to correspond to the L3 connections between the N7Ks and the WAN router.  Then, we could trunk these VLANs to each of the N5Ks, and configure one 1G port on each N5K for the VLAN, and connect the WAN router to the N5Ks.
    Two questions regarding this design:
    1) Is there a problem in connecting the L3 WAN router to the N7K via the N5K?
    2) Does vPC connectivity between the N7K and N5K pose a problem for the proposed WAN connectivity?
    Thanks in advance for any feedback.
    -rb

    The vPC between N5K and N7K is the catch here. Layer-3 routing over vPC member ports is currently not supported so I will advise you to stay away from this approach.
    Atif

  • Connecting 4 Nexus 2000 with Nexus 7000

    Hi ,
    I have two N7K-F248XP-25  going to be installed in one Nexus 7009 and I have 4 N2K-C2248TP-1GE (48x100/1000-T+4x10GE) .
    In simple way, I have two F2 line cards within one N7K and 4 N2Ks. The N7K will be used as a parent switch and it has NX-OS version 6.0
    So I want to connect the 4 N2K to the two F2 line cards in a redundant fasion, can some one tell me the best practice of how to connect those N2Ks?
    I have read somewhere that I can only use two ports from each 4 shared ports but I am not sure if this is true. I will appreciate any input or a link.
    Thanks

    That was Awesome link! Thanks indeed.
    So can you please confirm if I am following the F2 + FEX rule
    Again, I have only one Nexus 7009 and 4 x N2K , so I have two F2 cards on the Nexust 7009. Here is my connectivity plan:
    1st N2K to port 1 on the first F2
    1st N2K to port 1 on the second F2
    2nd N2K to port 2 on the first F2
    2nd N2K to port 2 on the second F2
    3rd N2K to port 3 on the first F2
    3rd N2K to port 3 on the second F2
    4rth N2K to port 4 on the first F2
    4rth N2K to port 4 on the second F2
    So eventually , I am planning to use one group (4 ports) on each F2 card for all the connectivity to those N2K Switches.
    Also, I will have a total of 4 port channels .. right ? 1 Port channel for each N2K
    I will appreciate your feedback!

Maybe you are looking for

  • I forgot my username for my iMac

    Hi, I am completely untechnical, so please help me in simple language!! I just returned from vacation and my MacBook had run out of battery. I haven't signed in for ages, as it was always turned on up til now and I had no need to sign in. I had to ch

  • How to read a txt file and update DB table

    I have to read a table which has some entries in it as plain text file, then I should update my table if the table entries and the data in text file are NOT MATCHING o.w. keep the table entry as it is

  • HTML into Flash please help!

    I want to put a HTML webpage into a certain field that is scrollable and when a link is clicked that box will change to give the content from the new page in that field ... please help, and also can javascript hover-off links from a webpage be put in

  • Emptying iPhoto trash causes iP crash

    and it rhymes! Using latest version of iPhoto, I was deleting a number of photos a week ago or so when iPhoto crashed. When I re-opened iP after a restart, everything seemed okay, so I proceeded to add more photos to the trash folder and tried again.

  • Any key to quickly switch between controllers in Piano Roll?

    in the LPX PIano Roll, can we use key commands or ipad Remote app to quicly switch between different midi controllers? Like switch between modulation/foot control, etc.