N7K - powered-dn module status

Hi guys,
Suddenly, one of the modules under 7K switch gave red alarm.
Following are the show module:
#show module
Mod  Ports  Module-Type                         Model              Status
4    0      10 Gbps Ethernet Module                                powered-dn
Mod  Power-Status  Reason
4    powered-dn     Unable to power up card (Power_OK not set)
Mod  Sw              Hw
1    6.2(6)          3.0     
3    6.2(6)          1.0    
Any common issue for that?
Regards.

Hi,
Please try this.
1. Set on config t the diagnostic bootup level complete
2. Reseat module 4
3. show diagnostic result module 4
4. show module
If you still face the same issue after reseating it then RMA the module. Also check the available power on the switch and the minimum version required for the module to run fine.

Similar Messages

  • Nexus 7009 does not show the N7K-F248XP-25 modules ethernet ports n sh run

    Hi everyone,
    I have a question...
    I going to install two Nexus 7009 with three N7K-F248XP-25  modules on each one, I am planning to create 3 VDC, but at the initial configuration the system does not show the Ethernet ports of these modules, even with the show inventory and show module I can see that the modules are recognized and its status is OK. There is something that I have to do before start to configure these modules...? enable some feature or license in order to see the ports with show running CLI...?

    You can enable F1, F2, M1, M1XL and M2XL Series modules. There are no restrictions on the type of mix allowed for the system module-type command. The system module-type command allows a mix of F1, F2, M1, M1XL, and M2XL Series modules in the VDC.
    Note The limit-resource module-type command controls the restrictions on the module-types that can be mixed in the VDC.
    Note Use the system module-type f2 command to allow F2E Series modules into a VDC. The ports from F2 and F2E Series modules can be allocated like any other ports.
    Note The modules that you do not enable must not be powered on after you configure this feature and enter yes. An error message will force you to manually disable these modules before proceeding. This prevents major disruption and service issues within a VDC.
    The no form of this command resets the configuration mode to allow all modules.
    hope this helps

  • Module status on LMS is showing as incomplete - even after the user has completed the module.

    Hi Folks,
    Hope you are all keeping well! I have a bit of a problem here. On a number of modules that were developed using presenter - and custom animation (including click next to continue) etc etc, the LMS is not showing the module status as complete - even AFTER the user had comleted the module and closed. This problem has been noticed only when the user uses the CLICK NEXT or click this part of the screen to continue.
    When the user navigates using the presenter control buttons - to navigate the training content that is, the LMS is correctly showing as the module has been completed.
    The problem I am having is that - is there any way to make presenter detect a click within a slide (user click to navigate from within a slide) and thereby register it as a valid module completion?
    Thanks in advance folks,
    Kind Regards,
    Alex.

    Hi Shubi,
    Thanks for you quick reply.
    Shubhi Shukla Dubey wrote:
    Hi Alex,
    Which LMS server you are using?  Secondly what is the Setting in Quiz>Reporting tab is it SCORM 1.2,2004 or Aicc.
    You want status on basis of user clicks then please make sure that Report data is set to "Slide view =100%" (or whatever precentage you want) and  Report Pass/Fail set to "Complete/ Incomplete."
    Thanks,
    Shubhi
    LMS = cornerstone on demand. It has been customised to suit the company requirements, Reporting tab is SCORM 1.2   
    To circumvent the issue I have changed the % view to 0% so in theory when the user launches even one slide / page - it will set it to report as status complete.
    However this is not a viable solution on content critical modules....dont you think so?
    Ideally I would like to get to the bottom of why a button within the module (which is able to navigate between pages) is not being able to report / set / increment the completion status counter.
    Thanks and Kind Regards,
    Alex.

  • ACE module status is unknown "FSM_FT_STATE_STANDBY_COLD",

    suddenly ACE module status is unknown “FSM_FT_STATE_STANDBY_COLD”, after reloading the FT worked fine , i need to know the root cause for this ?

    do a 'shut' / 'no shut' of the ft vlan interface.
    If that does not bring the interface up, check on the cat6k if FT vlan assigned to SVCLC group associated with ACE.
    You should also plan an upgrade to A2(2.4) since a similar problem was fixed.
    Gilles.

  • N7K-D132XP-15 module

    Is there any N7K-D132XP-15 module. I have seen this module reference in many other Cisco presentation. Is this a typo and correction would be N7K-F132XP-15 or a new module expected to be announce...

    Hello,
    So the fabric module that we have on the nexus 7000 will supply 46gbps per slot for each module you add:
    http://www.cisco.com/en/US/prod/collateral/switches/ps9441/ps9402/ps9512/Data_Sheet_C78-437760.html
    Depending on the modules you are using will dictate how many fabrics you need.  For example if you are using a N7K-M132XP-12L:
    http://www.cisco.com/en/US/prod/collateral/switches/ps9441/ps9402/data_sheet_c78-605622.html
    It has 80gb backplane connection, so to get full capabilitys of the module, you need 2 fabric modules.  You would likely want 3 for N+1 redundancy.
    However if you are using N7K-F132XP-15, it can make use of 230gb on the fabric...so for full capacity you would want 5 fabric modules:
    http://www.cisco.com/en/US/prod/collateral/switches/ps9441/ps9402/data_sheet_c78-605622.html
    Overall just check the datasheet for the modules you are using and by looking at switch fabric interface speed you should be able to plan out the number of fabrics you'll need for your cards.
    Hope that helps
    Chad

  • Itunes Install Crashes when it gets to Registering Modules status

    Appreciate any help someone could offer me on this. I've had the same thing happen several times. Every time I try to install the new version it gets stuck at this status. I can't figure what the problem is.
    I've gone to the Microsoft update page to make sure I had the most recent version of the service pack 4 and still it didn't finish the installation.
    Thanks for the help

    some folks have been having some success with gailj's technique with that one:
    gailj: Solution to registering modules hang for windows users

  • SG300-10SFP - Optical Module Status problem

    Hello,
    i have installed SG300-10SFP switch in one customer site, port g1-g9 is for customers and g10 for uplink to Metropolitan network
    after installation, all working fine, in port g10 i have installed SFP CWDM with DDI (diagnostics) all data like Temp, signal etc... switch displays correctly, after 60days i can check DDI info, but now switch displays only "N/A" value
    i can try reboot, but same value in WEB or CLI, in port status is all OK port is connected
    i have firmware
    1.3.5.58
    screen of status in attach

    Hi Thomas, investigating.
    -Tom
    Please mark answered for helpful posts

  • CSCtq89240 - Packets destined to the VDC MAC may be dropped by F1 module on N7K

    Even thougth If we configure the physical mac addresses for the SVI interfaces, the packets are not reaching the destination for some vlans

    Symptom:
    On the n7k packets destined to the VDC MAC may be dropped when received on a F1 module.
    Condition:
    N7k with F1 module. Packets destined to the VDC MAC will be dropped under the following conditions:
    - no SVI present or admin down
    - packets received on the F1 module
    Likely scenarios to see this condition include:
    - transparent firewall bridging
    - hair pinning traffic
    - L2 load balancers
    Workaround:
    Configure the SVI(s) with a user-configured mac address rather than using the default VDC MAC.
    This problem is isolated to the F1 module regardless of the NXOS version of code.
    Are the HSRP/VRRP/GLBP virtual MAC addresses also inserted into the RMM table?
    1)     If yes, will we have same impact and drop packets if bridged through the FW (when packets arrive on F1 port that does not have the SVI)
    No HSRP/VRRP/GLBP are not inserted in RMM. You will not have this issue for any other macs other than svi macs.
    2)     If HSRP vMAC is not in the RMM table, how does the F1 module know the packet has to be routed?
    It is through mac table. G bit set will indicate routing has to be done.

  • Cisco nexus 7706 Module x not responding... resetting

    Hello every body,
    we have in our data center 2 switches 7706 running NX-OS version 6.2(6a). One of them has notified that module 1 was not responding and rebooting it.
    2015 Mar 22 14:28:55 N7K-1 %MODULE-2-MOD_NOT_ALIVE: Module 1 not responding... resetting (Serial number: xxxx)
    2015 Mar 22 14:29:13 N7K-1 %PLATFORM-2-MOD_DETECT: Module 1 detected (Serial number xxxx) Module-Type 1/10 Gbps Ethernet Module Model N77-F348XP-23
    2015 Mar 22 14:29:13 N7K-1 %PLATFORM-2-MOD_PWRUP: Module 1 powered up (Serial number xxxx)
    2015 Mar 22 14:29:13 N7K-1 %PLATFORM-5-MOD_STATUS: Module 1 current-status is MOD_STATUS_POWERED_UP
    2015 Mar 22 14:30:50 N7K-1 %BIOS_DAEMON-SLOT1-5-BIOS_DAEMON_LC_PRI_BOOT:  System booted from Primary BIOS Flash
    2015 Mar 22 14:32:09 N7K-1 %VDC_MGR-5-VDC_STATE_CHANGE: vdc 1 state changed to updating
    2015 Mar 22 14:32:09 N7K-1 %VDC_MGR-5-VDC_STATE_CHANGE: vdc 1 state changed to active
    2015 Mar 22 14:32:33 N7K-1 %PLATFORM-5-MOD_STATUS: Module 1 current-status is MOD_STATUS_ONLINE/OK
    2015 Mar 22 14:32:33 N7K-1 %MODULE-5-MOD_OK: Module 1 is online (Serial number: xxxx)
    2015 Mar 22 14:32:33 N7K-1 %SYSMGR-SLOT1-5-MODULE_ONLINE: System Manager has received notification of local module becoming online.
    Fiew months ago we have the same symptom with module 6 instead of 1.
    Note that the VPC peer-link is connected over 2x10G interfaces on each of these 2 modules.
    Is there any known issue with this NX-OS version 6.2(6a)?

    Hi,
    I see that the module reloaded  to recover from a EOBC heartbeat failure.
    108) At 955385 usecs after Sun Mar 22 14:28:55 2015
        Sequence initiation: LC removal
    109) At 955209 usecs after Sun Mar 22 14:28:55 2015
        Sending MTS_OPC_LC_STATUS_CHANGE to Registry
    110) At 955206 usecs after Sun Mar 22 14:28:55 2015
        Received MTS_OPC_LCP_NOT_RESPONDING from Line card manager
    111) At 955148 usecs after Sun Mar 22 14:28:55 2015
        Sending MTS_OPC_LCP_NOT_RESPONDING to Line card manager
    112) At 458025 usecs after Sun Mar 22 14:28:19 2015
        Warning on ports: 1-0 due to EOBC heartbeat failure in device 10
    Device error code: 0xc0a0
    113) At 457788 usecs after Sun Mar 22 14:28:19 2015
        Received MTS_OPC_LC_RUNTIME_DIAG_FROM_SUP from EOBC monitor kernel SAP
    114) At 435569 usecs after Sun Mar 22 14:28:19 2015
        Warning on ports: 1-0 due to EOBC heartbeat failure in device 10
    Device error code: 0xc0a0
    115) At 435312 usecs after Sun Mar 22 14:28:19 2015
        Received MTS_OPC_LC_RUNTIME_DIAG_FROM_SUP from EOBC monitor kernel SAP
    N7K-1# show module internal exceptionlog module 1
    ********* Exception info for module 1 ********
    exception information --- exception instance 1 ----
    Module Slot Number: 1
    Device Id         : 10
    Device Name       : eobc
    Device Errorcode  : 0xc0a0314f
    Device ID         : 10 (0x0a)
    Device Instance   : 03 (0x03)
    Dev Type (HW/SW)  : 01 (0x01)
    ErrNum (devInfo)  : 79 (0x4f)
    System Errorcode  : 0x4042004e EOBC heartbeat failure
    Error Type        : Warning
    PhyPortLayer      : Ethernet
    Port(s) Affected  :
    DSAP              : 0 (0x0)
    UUID              : 0 (0x0)
    Time              : Sun Mar 22 14:28:19 2015
                        (Ticks: 550EC373 jiffies)
    exception information --- exception instance 2 ----
    Module Slot Number: 1
    Device Id         : 10
    Device Name       : eobc
    Device Errorcode  : 0xc0a0314d
    Device ID         : 10 (0x0a)
    Device Instance   : 03 (0x03)
    Dev Type (HW/SW)  : 01 (0x01)
    ErrNum (devInfo)  : 77 (0x4d)
    System Errorcode  : 0x4042004e EOBC heartbeat failure
    Error Type        : Warning
    PhyPortLayer      : Ethernet
    Port(s) Affected  :
    DSAP              : 0 (0x0)
    UUID              : 0 (0x0)
    Time              : Sun Mar 22 14:28:19 2015
                        (Ticks: 550EC373 jiffies)
    The EOBC is Ethernet Out of Band Channel.  
    There are regular keepalives or 'heartbeats' going between the sup and line cards.  The error messages you received indicate a heartbeat went missing between SUP and linecard. 
    If a single heartbeat went missing, it will be corrected automatically, however if multiple heartbeats are lost simultaneously then the line card would be reset (sup would power off and power on that slot in attempt to resolve a diagnostic issue).
    So if the card is stable after that you can consider this as a one time (transient) issue.
    You can also check EOBC stats to see if any error increasing.
    show hardware internal eobc stats
    show hardware internal eobcsw stats
    show hardware internal cpu-mac eobc stats
    show hardware internal cpu-mac eobc events
    show hardware capacity eobc
    Hope this helps. 
    PS : Please grade all posts which are useful.
    Thanks,
    Madhu.

  • Service Module is failed

    when i show service-module ids-sensor 1/0 status
    i have the following output
    Service Module is Cisco IDS-Sensor1/0
    Service Module supports session via TTY
    Service Module is failed
    Service Module status is not available
    what is the problem and how can i recover it?
    note i make restart for the service module by the command
    service-module ids-snsor 1/0 reset
    but it remain failed
    please help me as soon as possible

    You've powered off and re-seated the card and this was working at one point?  Beyond that, if there is no output from the CUE console (while connected to the module via "service-module service-engine 0/1 session"), then the module is likely defective.

  • CUE "Service Module is failed"

                       Dears , i am getting this error on CUE .I reload the router but result is same .what should i do now?? ..
    #service-module service-engine 0/1 status
    Service Module is Cisco Service-Engine0/1
    Service Module supports session via TTY line 258
    Service Module is failed
    Service Module status is not available
    Regards,
    Shib

    You've powered off and re-seated the card and this was working at one point?  Beyond that, if there is no output from the CUE console (while connected to the module via "service-module service-engine 0/1 session"), then the module is likely defective.

  • Enabling FCoE on N7K-F132XP-15

    I ran into a problem not being able to license FCoE on N7K-F132XP-15 module. I have the license file installed properly, but still getting "
    ERROR:  Cannot obtain license, line card is not supported".  It seems the problem is with version of HW on this particular module 1.0. Anyone has experience with this ?
    switch(config)# show module
    Mod  Ports  Module-Type                         Model Status
    1    32     10 Gbps Ethernet Module             N7K-M132XP-12 ok
    2    32     1/10 Gbps Ethernet Module           N7K-F132XP-15 ok
    5    0      Supervisor module-1X                N7K-SUP1 active *
    Mod  Sw              Hw
    1    6.0(4)          1.8
    2    6.0(4)          1.0
    5    6.0(4)          1.4
    Mod  MAC-Address(es)                         Serial-Num
    1    d0-d0-fd-f1-5d-00 to d0-d0-fd-f1-5d-24  JAF1429CJCR
    2    f8-66-f2-e4-d5-4c to f8-66-f2-e4-d5-90  JAF1704BFTD
    5    00-24-f7-1d-c3-08 to 00-24-f7-1d-c3-10  JAF1317BDBF
    Mod  Online Diag Status
    1    Pass
    2    Pass
    ==================================================================================
    switch(config)# show license usage
    Feature                      Ins  Lic   Status Expiry Date Comments
                                     Count
    MPLS_PKG                      No    -   Unused             -
    STORAGE-ENT                   No    -   Unused             -
    ENTERPRISE_PKG                No    -   Unused             -
    FCOE-N7K-F132XP               Yes   1   Unused 30 Jan 2014 -
    ENHANCED_LAYER2_PKG           No    -   Unused             -
    SCALABLE_SERVICES_PKG         No    -   Unused             -
    TRANSPORT_SERVICES_PKG        No    -   Unused             -
    LAN_ADVANCED_SERVICES_PKG     Yes   -   Unused Never       license missing
    LAN_ENTERPRISE_SERVICES_PKG   Yes   -   Unused Never       license missing
    =======================================================================================
    switch(config)# install feature-set fcoe
    feature set is installed already(0x40aa0011)
    switch(config)# li
    license   line
    switch(config)# license fcoe module 2
    ERROR:  Cannot obtain license, line card is not supported
    switch(config)#

    Padma, I think you solved the problem. The "license fcoe module 2 force" took affect (see output below). The "force" option is hidden, so I didn't make that guess on my own. I hope from here on the card should be able to handle FCoE configuration. If you know of any other pitfalls with this particular hardware revision, please share.
    n7k# show version
    Cisco Nexus Operating System (NX-OS) Software
    TAC support: http://www.cisco.com/tac
    Documents: http://www.cisco.com/en/US/products/ps9372/tsd_products_support_serie
    s_home.html
    Copyright (c) 2002-2012, Cisco Systems, Inc. All rights reserved.
    The copyrights to certain works contained in this software are
    owned by other third parties and used and distributed under
    license. Certain components of this software are licensed under
    the GNU General Public License (GPL) version 2.0 or the GNU
    Lesser General Public License (LGPL) Version 2.1. A copy of each
    such license is available at
    http://www.opensource.org/licenses/gpl-2.0.php and
    http://www.opensource.org/licenses/lgpl-2.1.php
    Software
      BIOS:      version 3.22.0
      kickstart: version 6.0(4)
      system:    version 6.0(4)
      BIOS compile time:       02/20/10
      kickstart image file is: bootflash:///n7000-s1-kickstart.6.0.4.bin
      kickstart compile time:  12/25/2020 12:00:00 [06/22/2012 19:26:16]
      system image file is:    bootflash:///n7000-s1-dk9.6.0.4.bin
      system compile time:     6/6/2012 18:00:00 [06/22/2012 21:03:20]
    Hardware
      cisco Nexus7000 C7010 (10 Slot) Chassis ("Supervisor module-1X")
      Intel(R) Xeon(R) CPU         with 8245320 kB of memory.
      Processor Board ID JAF1330AHKM
      Device name: n7k
      bootflash:    2030616 kB
      slot0:        2075246 kB (expansion flash)
    Kernel uptime is 0 day(s), 1 hour(s), 36 minute(s), 46 second(s)
    Last reset
      Reason: Unknown
      System version: 6.0(4)
      Service:
    plugin
      Core Plugin, Ethernet Plugin
    CMP (Module 5) ok
    CMP Software
      CMP BIOS version:        02.01.05
      CMP Image version:       5.1(1) [build 5.0(0.66)]
      CMP BIOS compile time:   7/13/2008 19:44:27
      CMP Image compile time:  11/29/2010 12:00:00
    ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
    n7k# attach module 2
    module-2# show hardware internal dev-version
    Name                     InstanceNum      Version
    Orion Fwding Driver              1           3.0
    Orion Fwding Driver              2           3.0
    Orion Fwding Driver              3           3.0
    Orion Fwding Driver              4           3.0
    Orion Fwding Driver              5           3.0
    Orion Fwding Driver              6           3.0
    Orion Fwding Driver              7           3.0
    Orion Fwding Driver              8           3.0
    Orion Fwding Driver              9           3.0
    Orion Fwding Driver             10           3.0
    Orion Fwding Driver             11           3.0
    Orion Fwding Driver             12           3.0
    Orion Fwding Driver             13           3.0
    Orion Fwding Driver             14           3.0
    Orion Fwding Driver             15           3.0
    Orion Fwding Driver             16           3.0
    PHY                              1          56778642.1291
    PHY                              2          56778642.1291
    PHY                              3          56778642.1291
    PHY                              4          56778642.1291
    PHY                              5          56778642.1291
    PHY                              6          56778642.1291
    PHY                              7          56778642.1291
    PHY                              8          56778642.1291
    PHY                              9          56778642.1291
    PHY                             10          56778642.1291
    PHY                             11          56778642.1291
    PHY                             12          56778642.1291
    PHY                             13          56778642.1291
    PHY                             14          56778642.1291
    PHY                             15          56778642.1291
    PHY                             16          56778642.1291
    Santa-Cruz-Module                1           0.4
    Santa-Cruz-Module                2           0.4
    Falcon                           1           2.0
    IO FPGA                          1          0.045
    PM FPGA                          1          1.001
    BIOS version                       v1.10.17(04/25/11)
    Alternate BIOS version             v1.10.17(04/25/11)
    module-2# 
    ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
    n7k(config)# license fcoe module 2
    ERROR:  Cannot obtain license, line card is not supported
    n7k(config)# license fcoe module 2 force
    n7k(config)# show license usage
    Feature                      Ins  Lic   Status Expiry Date Comments
                                     Count
    MPLS_PKG                      No    -   Unused             -
    STORAGE-ENT                   No    -   Unused             Grace 119D 23H
    ENTERPRISE_PKG                No    -   Unused             Grace 119D 22H
    FCOE-N7K-F132XP               No    0   Rsrved             Grace 81D 3H
    ENHANCED_LAYER2_PKG           Yes   -   In use Never       license missing
    SCALABLE_SERVICES_PKG         No    -   Unused             -
    TRANSPORT_SERVICES_PKG        Yes   -   Unused Never       license missing
    LAN_ADVANCED_SERVICES_PKG     Yes   -   In use Never       license missing
    LAN_ENTERPRISE_SERVICES_PKG   Yes   -   Unused Never       license missing

  • Catalyst 4506 and Modules in Pwr Over state

    Hello,
    First of all, my excuses for my bad english.
    I am experiencing a problem with a Cisco Catalyst 4506.
    The switch is filled with 48 port PoE blades (WS-X4248-RJ45V).
    The error we receive is:
    Sept 5 15:40:12: %C4K_IOSMODPORTMAN-4-INLINEPOWEROVERWARNING: Inline power exceeds threshold: Module status changed to 'Pwr Over'
    Sept 5 16:37:04: %C4K_IOSMODPORTMAN-6-INLINEPOWEROK: Inline power within limits: Module status changed to 'Ok'
    Sept 5 16:37:04: %C4K_IOSMODPORTMAN-6-MODULEONLINE: Module 6 (WS-X4248-RJ45V S/N: JAB080609GN Hw: 2.0) is online
    According to the Cisco website:
    Explanation
    This message indicates that the measured PoE is at least 50 w higher than the configured value. The switch has either misconfigured PoE or an unauthorized powered device that is connected to the switch and is drawing a lot of PoE.
    Out put for the commands sh power details and sh module all are attached.
    The switch has no PoE devices on the specific blade.
    Atleast not that we know.
    Does any one know some other solution?
    Thanks in advance.
    Martijn Groenleer

    Well, blade six went offline on the first row of the log i posted earlier.
    The problem is, the log doesn't mention in the message which module went offline.
    About the 'efficiency' i noticed this also, what could be causing this? Power supplies are already replaced. PoE is on default settings currently.
    A full log related to these power over warnings:
    Aug 30 23:27:00: %C4K_IOSMODPORTMAN-4-INLINEPOWEROVERWARNING: Inline power exceeds threshold: Module status changed to 'Pwr Over'
    Aug 30 23:39:34: %C4K_IOSMODPORTMAN-6-INLINEPOWEROK: Inline power within limits: Module status changed to 'Ok'
    Aug 30 23:39:34: %C4K_IOSMODPORTMAN-6-MODULEONLINE: Module 6 (WS-X4248-RJ45V S/N: JAB080609GN Hw: 2.0) is online
    Sep 3 08:45:46: %C4K_IOSMODPORTMAN-4-INLINEPOWEROVERWARNING: Inline power exceeds threshold: Module status changed to 'Pwr Over'
    Sep 3 08:57:49: %C4K_IOSMODPORTMAN-6-INLINEPOWEROK: Inline power within limits: Module status changed to 'Ok'
    Sep 3 08:57:49: %C4K_IOSMODPORTMAN-6-MODULEONLINE: Module 6 (WS-X4248-RJ45V S/N: JAB080609GN Hw: 2.0) is online
    Sep 4 01:53:04: %C4K_IOSMODPORTMAN-4-INLINEPOWEROVERWARNING: Inline power exceeds threshold: Module status changed to 'Pwr Over'
    Sep 4 02:23:16: %C4K_IOSMODPORTMAN-6-INLINEPOWEROK: Inline power within limits: Module status changed to 'Ok'
    Sep 4 02:23:16: %C4K_IOSMODPORTMAN-6-MODULEONLINE: Module 6 (WS-X4248-RJ45V S/N: JAB080609GN Hw: 2.0) is online
    Sep 4 16:10:58: %C4K_IOSMODPORTMAN-4-INLINEPOWEROVERWARNING: Inline power exceeds threshold: Module status changed to 'Pwr Over'
    Sep 4 17:20:23: %C4K_IOSMODPORTMAN-6-INLINEPOWEROK: Inline power within limits: Module status changed to 'Ok'
    Sep 4 17:20:23: %C4K_IOSMODPORTMAN-6-MODULEONLINE: Module 6 (WS-X4248-RJ45V S/N: JAB080609GN Hw: 2.0) is online
    Sep 4 17:58:14: %C4K_IOSMODPORTMAN-4-INLINEPOWEROVERWARNING: Inline power exceeds threshold: Module status changed to 'Pwr Over'
    Sep 4 18:09:37: %C4K_IOSMODPORTMAN-6-INLINEPOWEROK: Inline power within limits: Module status changed to 'Ok'
    Sep 4 18:09:37: %C4K_IOSMODPORTMAN-6-MODULEONLINE: Module 6 (WS-X4248-RJ45V S/N: JAB080609GN Hw: 2.0) is online
    Sep 4 19:13:15: %C4K_IOSMODPORTMAN-4-INLINEPOWEROVERWARNING: Inline power exceeds threshold: Module status changed to 'Pwr Over'
    Sep 4 19:56:11: %C4K_IOSMODPORTMAN-6-INLINEPOWEROK: Inline power within limits: Module status changed to 'Ok'
    Sep 4 19:56:11: %C4K_IOSMODPORTMAN-6-MODULEONLINE: Module 6 (WS-X4248-RJ45V S/N: JAB080609GN Hw: 2.0) is online
    Sep 5 09:02:16: %C4K_IOSMODPORTMAN-4-INLINEPOWEROVERWARNING: Inline power exceeds threshold: Module status changed to 'Pwr Over'
    Sep 5 09:10:46: %C4K_IOSMODPORTMAN-6-INLINEPOWEROK: Inline power within limits: Module status changed to 'Ok'
    Sep 5 09:10:46: %C4K_IOSMODPORTMAN-6-MODULEONLINE: Module 6 (WS-X4248-RJ45V S/N: JAB080609GN Hw: 2.0) is online
    Sep 5 15:40:12: %C4K_IOSMODPORTMAN-4-INLINEPOWEROVERWARNING: Inline power exceeds threshold: Module status changed to 'Pwr Over'
    Sep 5 16:37:04: %C4K_IOSMODPORTMAN-6-INLINEPOWEROK: Inline power within limits: Module status changed to 'Ok'
    Sep 5 16:37:04: %C4K_IOSMODPORTMAN-6-MODULEONLINE: Module 6 (WS-X4248-RJ45V S/N: JAB080609GN Hw: 2.0) is online

  • Cisco 6500 power supply and module (hot-swappable?)

    Hi everyone!
    We have currently a Cisco 6500 with 2 power supply of 3000w. We want to replace these PS for 2 new ones, which have higher wattage: 6000w. 
    Can we replace them without needing to turn the 6500 off?. I mean, What happens if we insert a 6000w PS and the switch is working with one 3000w PS?
    Is it possible to do this replacement "on hot"?
    And second, we also have a ws-x6708-10g-3c module. Can we insert this module "on hot"? Without needing to turn the Catalyst 6500 off? 
    Thanks a lot! and looking forward to an answer.

    Depends on your setup the table should be able to help:
    http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst6500/ios/12-2SX/configuration/guide/book/pwr_envr.html#wp1020384
    Configuration Change
    Effect
    Redundant to nonredundant
    •System log and syslog messages are generated.
    •System power is increased to the combined power capability of both power supplies.
    •Modules marked power-deny in the show power oper state field are brought up if there is sufficient power.
    Nonredundant to redundant (both power supplies must be of equal wattage)
    •System log and syslog messages are generated.
    •System power is decreased to the power capability of one supply.
    •If there is not enough power for all previously powered-up modules, some modules are powered down and marked as power-deny in theshow power oper state field.
    Equal wattage power supply is inserted with redundancy enabled
    •System log and syslog messages are generated.
    •System power equals the power capability of one supply.
    •No change in module status because the power capability is unchanged.
    Equal wattage power supply is inserted with redundancy disabled
    •System log and syslog messages are generated.
    •System power is increased to the combined power capability of both power supplies.
    •Modules marked power-deny in the show power oper state field are brought up if there is sufficient power.
    Higher or lower wattage power supply is inserted with redundancy enabled
    •System log and syslog messages are generated.
    •The system does not allow you to operate a power supply of different wattage even if the wattage is higher than the installed supply. The inserted supply shuts down.
    Higher or lower wattage power supply is inserted with redundancy disabled
    •System log and syslog messages are generated.
    •System power is increased to the combined power capability of both power supplies.
    •Modules marked power-deny in the show power oper state field are brought up if there is sufficient power.
    Power supply is removed with redundancy enabled
    •System log and syslog messages are generated.
    •No change in module status because the power capability is unchanged.
    Power supply is removed with redundancy disabled
    •System log and syslog messages are generated.
    •System power is decreased to the power capability of one supply.
    •If there is not enough power for all previously powered-up modules, some modules are powered down and marked as power-deny in theshow power oper state field.
    System is booted with power supplies of different wattage installed and redundancy enabled
    •System log and syslog messages are generated.
    •The system does not allow you to have power supplies of different wattage installed in a redundant configuration. The lower wattage supply shuts down.
    System is booted with power supplies of equal or different wattage installed and redundancy disabled
    •System log and syslog messages are generated.
    •System power equals the combined power capability of both power supplies.
    •The system powers up as many modules as the combined capacity allows.

  • Bad memory modules or motherboard??

    I rearranged the cables in my case and now I'm not able to boot using dual channel memory configuration. It worked before just fine!
    I've got two 512MB twinmos twister pc3500 modules.
    D-bracket indicates bad memory module if I try to setup dual channel using dimm 1 and dimm 3. I've tried other dual channel combinations with the same result.
    I can only boot using dimm 1! using the other slots get me the bad memory module status on the d-bracket. I've tested both mem modules in slot 1 and I am able to boot so it seems the mem modules are OK. Or are they OK for just single channel config?
    Do I have a faulty motherboard or are the memory modules bad?
    MSI 865PE neo2 fisr rev 1.00
    2x512MB twinmos twister pc3500

    Christ! what is it with these MSI boards?
    The 2 848P's i tried both worked fine with a single 512mb strip in, but put another in and the D Bracket Light 2 stays and the PC fails to boot or reboot properly - it's totally hit n miss.
    See my thread for the unbelievable amount of problems i've had with the 848P! :
    http://www.msi.com.tw/program/e_service/forum/index.php?threadid=31192&sid=
    I'm RMA'ing both 848P's as i've tried everything, now even the forum moderators say rma the boards so i know its nothing trivial happening here... They're even going to get MSI to look at my thread - so hopefully they will take notice!  
    Am i to take it that the 865 also has similar problems, ffs!
    Is there a stable MSI mobo available that will take 2 DDR's sticks or not?  

Maybe you are looking for

  • XE and "Cannot find server or DNS Error"

    I read other articles and here is some data for your to go over. ===================================================================== SQL*Plus: Release 10.2.0.1.0 - Production on Tue Nov 28 09:37:18 2006 Copyright (c) 1982, 2005, Oracle. All rights

  • TS1506 My attachment symbol is not visible when I am sending an email. How do I get it back?

    Attachment option is not visible when sending an email through aol.com.

  • On Sync, Apps Try to Load on Multiple iPhones

    Folks...  I've got something driving me crazy may actually be a simple fix, but I cannot seem to find the solution. I have 5 family iPhones sync'ing to the same MacPro.  My kids all have many many apps, and my wife and I only have 5-8 each.  The prob

  • Use of 0Mat_Sales

    Hello - I have an issue where there are 3 sales orgs, an article can exist in all 3 of these sales orgs and have a  different retail price in each sales org. I want to be able to display the article retail price per sales org in a query or alternativ

  • Util.regex.Pattern documentation

    The 1.5 documentation for util.regex.Pattern defines quantifiers that are greedy, reluctant, or possessive. The definitions of these quantifiers seem to be the same. For example, X?, X??, and X?+ are each defined as "X, once or not at all." Is this a