National Instrument Software Crashing VXI Processor

Everytime I work with MAX v3.0 the Windows 2000 based VXIPC-872B that I have crashes. Upon recovery, the Event Viewer says that " The computer has recovered from a bugcheck located at 0x00000076 (0x00000000, 0x822df8e0, 0x00000001, 0x00000000) Microsoft Windows v15.2195 ..." It goes on to say that a memory dump has occured. What is causing this? How can I fix this problem?

Hitman-
The 872B is a normal PC in a different form factor. So the fact that it is VXI is not going to cause this problem. Have you already tried repairing your MAX installation? It is possible if there was an error during the initial installation that something like this might occur. What hardware are you using with the VXI Chassis? Does this problem occur even when the chassis is empty? Sometimes these types of problems occur when HW conflicts are present.
I hope this helps. If you are still seeing the problem, let me know which other NI drivers you are using, and specifically, which one installed MAX 3.0 that you are using.
Dustin

Similar Messages

  • Why can't national instruments software recognize my CEC GPIB card.

    I am trying to use national instruments software with a plug and play cec (Capitol Equipment) PCI GPIB card. The device shows up (as working properly) in device manager. I also downloaded and installed new drivers from the CEC website. However National Instruments software does not recognize the card's existance.

    What NI software are you trying to use and what drivers from CEC did you install? Low level NI functions like ibwrt, ibrd, or LabVIEW GPIB functions only work with NI boards. If CEC provides a VISA installation, you should be able to use that and NI VISA calls. Otherwise, you'll have to use the CEC functions.

  • What exactly do the national instrument​s citadel nt service and the lookout citadel nt service run

    We have WhatsUp monitoring software set to monitor NI Lookout and the PC it is on.  It pings the PC, and polls the Lookout Citadel Server NT service.  If either one fails, WhatsUp sends an email notification.  I was under the impression if the Lookout Citadel Server service is down, then NI Lookout won't graph or record data, but that's not the case.  If I shut Lookout Citadel Server or National Instruments Citadel Server down, NI Lookout still graphs and records.  What exactly do these two services run?
    Also, is there a possibility that NI Lookout can be viewed through palm OS software, like a Blackberry?

    Lookout Citadel Server is for Citadel 4, which is used by Lookout 5 and DSC 7.
    NI Citadel is for Citadel 5, used by Lookout 6 and DSC 8.
    If Citadel is stopped, Lookout will start it up automatically when launched. But if Citadel is stopped when Lookout is running, there might be some unexpected issues, although the data logging seems to be working well.
    So I strongely recommend you not to stop those Citadel service when Lookout is running.
    Lookout cannot be running on palm OS.
    Ryan Shi
    National Instruments

  • Multiple openings at National Instruments RF R&D, Bangalore

    Hi All,
    Multiple openings at National Instruments RF R&D, Bangalore
    1. Staff Engg: 3-5years of experience
    Need good programming skills in C/C++, Experience in WIX/WISE, shell scripting
    2. Staff Engg: 3-5years of experience in LabVIEW programming.
    3. Fresher: BE (CS) 2013/14 pass out. Needs to join immediately. 
    If you know someone from a reputed school with >75% aggregate
    4. Staff Engg: 3-5 years of experience in C/C++ and .Net.
    5. Staff Engg: 3-5 years of experience in PHY layer
    Forward your resumes/refer your friends if they fit to the above JD.
    Email: [email protected]
    Regards,
    Suresh S
    Staff Advanced Software Engineer
    RF R&D, NI-Bangalore

     I earned a B.E. in Electronics and Communication from PES Institute of Technology & Management – Shimoga and has secured overall aggregate of 73% in engineering  and I have ample experience in creating, designing, and updating software programs for small to medium sized AEROSPACE Application. I know this is a perfect match for your needs, as you service the same market; and thus, I have the right qualifications for this position.
    PERSONAL SUMMARY
    R&D professional with around 1.5 years’ experience in conceptualization and development of microcontroller based products and solutions.
    Good programming experience in Embedded C & C.  
    Having knowledge on I2C, UART, SPI, and CAN.  
    Having good work experience with interfacing devices with microcontrollers.    
    Experience in hardware and software testing & debugging.   
    Hands on experience in Simulation tools like Proteus 8 and Multisim12.0     
    Having work experience with 8051 microcontrollers.     Able to understand and learn the new concepts in short term.
    Responsibilities:
    Design and Development of the embedded systems.
    Real time testing of the developed embedded systems                     
    Thanks& Regards,

  • Who Makes National Instruments Real-Time Operating System?

    My simple question for reference is Who Makes National Instruments Real-Time Operating System?  I just need to know the company and if you happen to have a link to their website that would also be great!   Thanks.
    Michael B

    On Oct 8, 12:10 pm, tbob <[email protected]> wrote:
    > NI does not own a real time OS.&nbsp; They make Labview Real Time, but the OS is made and owned by other companies.&nbsp; There are several to choose from.&nbsp; If you Google "RTOS" you will see several hits.&nbsp; One of them is Express Logic's RTOS.&nbsp; <a href="http://www.rtos.com" target="_blank">www.rtos.com</a>
    > &nbsp;
    When you try to determine whether Real-Time RTX can coexist with
    Windows, National Instruments directs you to a Citrix Web Page for
    evaluation software. At Citrix's Web Page I couldn't find any
    evaluation software but the page mentions ETS And RTX versions of the
    Real-Time software. I also concluded Phar Lap was the original
    developer of the Real Time software. It appears Phar Lap was owed by
    Venturcom and then Citrix bought Venturcom. Phar Lap dates back to the
    19 eighties when PCs were first becoming popular
    Here is the link that led to these comments.
    http://digital.ni.com/public.nsf/allkb/03BC0810E60CE93286256E7D007B61F5
    Howard

  • Connecting OPCUDS 2.5 to National Instruments' LabVIEW

    Has anyone had to work with National Instruments' LabVIEW OPC server and succesfully connected to it via the UDS 2.5?
    Currently trying to achieve this and am having major issues with the UDS crashing the LabVIEW service everytime it is started.
    Thank You!

    No experience but it could be because of a large volume of Tags on the server.
    What about any other OPC client?
    I had a nearly similar experience with RSLinx when the UDS seemed to stop responding everytime we started it (it did not affect the OPC server though) and finally what we found was, all the UDS needed was some time to actually establish the connection because of the large number of Tags on the server.

  • NATIONAL INSTRUMENT​S LABVIEW REALTIME V6.1, NI-488.2 V2.01, CNC CADCAM

    IAR, NATIONAL INSTRUMENTS LABVIEW REALTIME V6.1, NI-488.2 V2.01, CNC CADCAM
    IAR,
    Microwave Design Office 2002, Cadence, OrCAD, Protel, FPGA, VHDL,
    Natinst, Xilinx, Siemens Simatic, Labview, metrowerks codewarrior8
    [2CDs],
    other 20 gigabytes/week software for pc and mac
    send email for catalogue

    Hello,
    Which driver have you on your computer ? You can see them in MAX >> Software. Which is version of ni-visa, ni-488.2 ?
    What kind of protocol do you want to use : gpib, serial, parallel ?
    What ahhpens in AMX when you test your communication ?
    What are error code and error string ?
    Regards,
    Isabelle
    Ingénieur d'applications
    National Instruments France

  • Does National Instruments produce a DAQ equivalent of an electronic load for fuel cell testing?

    I am trying to consider my options before purchasing an electronic load. I would like to use LabView software to record and analyze my data that I will be generating during fuel cell testing. I was just wondering if National Instruments produced an instrument similar to an electronic load or a couple instruments that could work in combination similarly to an electronic load. I have looked through the available DAQ instruments on the NI website and it seems that they all output signals too low for my application. The fuel cell I will be using outputs voltage from 0-2VDC and current from 0-4A. I understand the internal workings of an electronic load and realize that the best option would be to implement some sort of variable resistor to act as the load in my circuit, then use DAQ instruments to measure current and voltage respectively. The problem is that the range of my current, especially, is much larger than any allowable input range for any NI DAQ instruments.
    Any input would be much appreciated. Also if you have developed a testing system for fuel cells or other low power DC sources, please share any knowledge and information about how you went about designing your system.
    Thanks

    TravisW wrote:
    I am trying to consider my options before purchasing an electronic load....
    Any input would be much appreciated. Also if you have developed a testing system for fuel cells or other low power DC sources, please share any knowledge and information about how you went about designing your system.
    Thanks
    We used a DC Programmable Electronic Load from AMREL.
    WE used GPIB to talk to each of them The loads ley us set constant current/voltage and let us query the current values etc.
    Worked fine for us,
    Ben
    Ben Rayner
    I am currently active on.. MainStream Preppers
    Rayner's Ridge is under construction

  • Non National Instrument​s DAQ Boards

    How do you configure (add) a non-National Instruments DAQ board, which is compatable with labview (IOtech DAQBoard 2000 - PCI), in the "Measurment and Automation Explorer" for LabVIEW?  It currently does not display that the device is seen under the "Devices and Interfaces" section.  All necessary software for the board has already been installed.  Any help would be greatly appreciated.

    Duplicate post at http://forums.ni.com/ni/board/message?board.id=170​&message.id=132322 and http://forums.ni.com/ni/board/message?board.id=140​&message.id=12952.
    Please try to avoid posting the same question to multiple forums. Pick the one that you think is the most appropriate and wait a while before posting it somewhere else.

  • Non National Instruments DAQ Boards

    How do you configure (add) a non-National Instruments DAQ board, which is compatable with labview (IOtech DAQBoard 2000 - PCI), in the "Measurment and Automation Explorer" for LabVIEW?  It currently does not display that the device is seen under the "Devices and Interfaces" section.  All necessary software for the board has already been installed.  Any help would be greatly appreciated.

    Hi,
    MAX is a program from NI, to configure and test NI boards, it is not meant to use with boards from another manufacturers.
    You should use tools that should be available from your board manufacturer.
    Paulo.

  • Why Does My Mac Software Crash?

    I'm a new Mac user (I converted to Mac after 15 years of torment on a Windows PC just two weeks ago). It's the 20" Intel iMac with 512MB Ram. I've installed just 3 third-party applications on here (Microsoft Messenger, Google Earth and Skype). I've also installed some widgets from the Apple.com website. I also updated the Mac when I first got it, so it's all up to date. Just for reference, I usually always have Messenger open when I connect to the internet.
    The only problem is, a few applications have crashed a few times. It first happended on Safari whilst browsing the web. It also happened on Pages (the bought version) and then again on iDVD and iMovie HD. The applications just shut down, and brought up a box asking me if I wanted to either reload the app or send a message to Apple about this.
    A few people have said it might be due to the fact that Messenger is the only app I am running that is still using the PowerPC code. Messenger has been open every time these other apps were running - I am 99.9% sure of it.
    I just wanted some advice from more experienced Mac users. The reason I upgraded to Mac was to get away from petty things like software crashes...
    Many thanks.
    Intel iMac (20")   Mac OS X (10.4.7)  
    Intel iMac (20")   Mac OS X (10.4.7)  

    Well, one other thing I have noticed, and being a new
    Mac user I am not sure if this is normal, but when I
    first load an application up (say Safari), the Dock
    animations are not as smooth, they are a little bit
    jumpy. This also happens if there is more than a few
    apps running - though I just put this down to a busy
    CPU or the fact that I only have the standard 512MB
    Ram.
    I think we might be getting to the root of the problem here; if you're using a PowerPC app under Rosetta, it will suck up an awful lot of RAM. From what I have read, an iMac with 512MB is like a different computer compared to an iMac with 1GB+. You should really consider purchasing some more RAM; I don't know why Apple even bother shipping Macs with less than a GB as standard.
    If you want an instant messaging app that is a Universal Binary (i.e. compatible with Intel processors), check out the excellent (and free) Adium. It can connect to MSN, Yahoo, Google Talk, Jabber, ICQ, and more.
    Also, something else I wanted to ask if I may. When I
    downloaded the system updates via the Apple logo on
    the menu bar, something a little strange happened
    when it got round to installing the firmware update.
    The system had to restart, but as the Apple logo
    appeared on-screen, the fans inside kicked into the
    highest of high gears - it made a really loud noise,
    as if spinning five times faster than usual. Now,
    everytime I power the machine up, the fans give a
    little 'growl' as it boots (but this only lasts for a
    fraction of a second, and its only maybe twice as
    loud as the fans would normally be). I just thought
    I'd ask if this was normal behavior. Again, being a
    new Mac user I am finding I have to re-learn a few
    things, hehe.
    Yes, this is all normal behaviour (at least I hope it is, because my iMac does it too! lol).
    What do you mean by create another account? I have
    yet to fully explore my Mac's more exotic features.
    By the way, this doesnt happen every day. It has now
    been a few days since it last happened.
    If you're having a problem with your Mac, it can sometimes be beneficial to go to System Preferences > Accounts, and create a new user account. If the problem exists on the new account too, then it is a system-wide problem; if it doesn't occur, then it is likely something in the original account (such as a corrupted preference file) is causing the problem, and it rules out a hardware fault.
    It's just a process of elimination that can help narrow down the list of possibilities, but I think Rosetta is the cause of your problems. Try out Adium and see if that makes things any better.

  • LV runtime error in file C:\Program Files\National Instruments\LabVIEW 2010\CCodeGen\libsrc\os\rtx\LVThreads_rtx.c

    Hello,
    I tried to run my application on LM3S8962.
    The build succeeded. All LEDs are green,
    but the application doesn't run.
    The error message appears in the status window:
    [17:06:21] Status: Build Succeeded.
    LV runtime error in file C:\Program Files\National Instruments\LabVIEW 2010\CCodeGen\libsrc\os\rtx\LVThreads_rtx.c at line 141: 2 19
    This message isn't really enlightening to me.
    Doesn't anyone know how to solve the problem?

    Hi Peter,
    i tried to modify the code to isolate the problem.
    With the attached code the new error message appears:
    LV runtime error in file C:\Program Files\National Instruments\LabVIEW 2010\CCodeGen\libsrc\blockdiagram\CCGClusterSupport.c at line 141: 2 13
    What are the limits of clusters in LV ARM?
    My Toolchain:
    Tool Version Numbers:
    Toolchain:        RealView MDK-ARM  Version: 4.11
    Toolchain Path:    BIN40\
    C Compiler:         Armcc.Exe       V4.0.0.728
    Assembler:          Armasm.Exe       V4.0.0.728
    Linker/Locator:     ArmLink.Exe       V4.0.0.728
    Librarian:             ArmAr.Exe       V4.0.0.728
    Hex Converter:      FromElf.Exe       V4.0.0.728
    CPU DLL:               SARMCM3.DLL       V4.11
    Dialog DLL:         DLM.DLL       V1.19a
    Target DLL:             BIN\UL2CM3.DLL       V1.63
    Dialog DLL:         TLM.DLL       V1.19a
    Thanks
    Marco
    Attachments:
    ICUA4_SOURCE_DISTRIBUTION.zip ‏463 KB

  • PLZ HELP?? I THINK MY SOFTWARE CRASHED? HOW DO I FIX THE PROBLEM???​?

    my bb all of a sudden just blanked out on me...i have on idea what is wrong with it or how to fix it!!! PLEASE help!!!! the phone went dead so i plugged it up to charge and when i came back to the phone it was on the blackberry screen and it was loading LIKE NORMAL BUT THENit would finish loading it was like it was stuck then it would blank out and start all over loading again. i have tried battery pull but i knew it wouldnt work cause the problem was much worse. did the software crash or something???? HOW CAN I FIX IT??? IM LOST AND DONT KNOW WHERE TO EVEN START TO TRY AND FIX IT!!!!

    bunnybunny wrote:
    I am having the SAME problem too!!!! I installed a new app... and my bb is dead... anyone can help me?
    Dead, as in a black screen and the red LED blinks?
    If your BlackBerry stays powered off with a black screen, follow the instructions below. The only indication of life might be the blinking red LED light in the top corner. Nothing seems to wake it up and Desktop Manager doesn't recognize any device is connected.
    1) Make sure you have Blackberry Desktop Manager installed.
    http://na.blackberry.com/eng/services/desktop/
    2) On your PC, go to Start > Run and copy and paste the following line exactly (meaning with the quotation marks):
    "c:\program files\common files\research in motion\apploader\loader.exe" /nojvm
    3) The Application Loader Wizard will appear -- click "Next."
    4) In the "Connection:" drop-down menu, you should see "USB-PIN: UNKNOWN". Click the "Next" button.
    5) You should then see a list of applications ready to be installed for your Blackberry. Hit Next and Finish and you are well on your way to getting your Blackberry back to life. Just don't disconnect anything and let the lengthy process finish completely.
    NOTE: If you do not see a list of applications mentioned in step 5 and instead see the message "The Blackberry Desktop Software does not have Blackberry Device Software for the device that you have connected to the computer. Contact your wireless service provider or system administrator," then you must download Blackberry's Operating System for your carrier and device.
    http://www.blackberryfaq.com/index.php/BlackBerry_​Operating_System_Downloads
    Just select the appropriate carrier and network type, select your Blackberry model from the list and download the latest version. Install this download and follow the above steps again and you should be on the right path.
    1. If any post helps you please click the below the post(s) that helped you.
    2. Please resolve your thread by marking the post "Solution?" which solved it for you!
    3. Install free BlackBerry Protect today for backups of contacts and data.
    4. Guide to Unlocking your BlackBerry & Unlock Codes
    Join our BBM Channels (Beta)
    BlackBerry Support Forums Channel
    PIN: C0001B7B4   Display/Scan Bar Code
    Knowledge Base Updates
    PIN: C0005A9AA   Display/Scan Bar Code

  • IMac issues: Overheating, Software Crashing, Screen Burn

    To whomever is helpful,
    My 24" iMac, early 2008 model has been experiencing problems that have gotten progressively worse over the past three months. The iMac began to heat up more than usual, and it's gotten hotter progressively over that course. The iMac is almost unusable after thirty minutes unless the screen brightness is turned down as low as possible. Software crashes, everything from advanced programs such as the Adobe suite, and the Chrome web browser which is not supposed to tax the memory very much, if at all. I have 4 gigs of RAM installed, and I believe the issue is heat related. As a sidenote, if the iMac gets hot enough, there is screen burn when moving application windows, and they disappear only after 10 minutes in sleep mode.
    In my mind, all of this is abnormal, and earlier today I tok my iMac to the Genius Bar at my local Apple Store, and the Genius didn't spend five minutes diagnosing my problems likely because there was a long line of people waiting. All he told me was to go home and run Activity Monitor and Disk Utility to see if there's a problem, and also to reinstall the operating system and the applications that crash. I've tried that, and as expected it didn't do anything, and I'm wondering if anyone has insight that could be of use, and if maybe I should send my iMac to AppleCare for them to look at it. Any help would be greatly appreciated appreciated.
    Regards,
    -Chad

    Chad, very sorry to hear of your problems.
    If your Mac is still under warranty (sounds like it might be) I'd suggest the following.
    Call Apple, and politely request they send a warranty tech to your location to address the issue.
    Ask that the tech come prepared to replace your Mac if they are unable to fix it.
    Although I am not an expert, this doesn't sound like a problem you could have caused. If you didn't break it, you shouldn't have to be involved in fixing it. You paid good money for a product, and you deserve to have it.
    Again, I'm assuming you're still under warranty.
    If you decide to try this, I hope you'll report how it works out for you, so we can learn from your experience. Thanks, and good luck!

  • Is there any alternate National Instruments Academic board for Altera DE2 Development & Education Board (P/N DE2-BRD-C35/UNIV)

    Hi,
    I am trying to compete with Altera DE2 Development & Education Board. Please let me know if National Instruments has equal product to DE2 Board. I look forward to your prompt response.
    Best regards,
    Vicky

    Hi Vicky,
    We have numerous Academic Product Bundles, to suit different needs. You would be interested in looking at the following post which talks about the Spartan-3E board. I would suggest contacting us at 1-888-280-7645 for more information. Hope this helps.

Maybe you are looking for

  • How to extend the extractor 0FC_BP_ITEMS?

    Hi everybody, Has anyone any information about extend the extractor 0FC_BP_ITEMS? Does it run with a tipical user exit? Thanks and regards! MML

  • How to restrict the authorization to change backgroud configuration

    hello , I copy some users from my admin user which contain the sap_all profile. so these uses can change background configuration.     now,  I want to restrict the authorization that they can only view the background configuration but can not change

  • Hi friends need some help in ALE  IDOC !

    For training purpose I am trying to create an IDOC using ALE where I am  using the same client as server as well as receiver......So I am using as receiver "NONE" . this is already present in the SM59 under logical systems.. But i cant create a port

  • Installing oracle xe on centos ci environment

    Hi, I have a CI environment that run automated tests on my application every time a commit is pushed to github, the tests are run on a matrix of environments to check if the application is able to run with different databases. I currently have tests

  • Connecting SBC dsl to ethernet hub?