Need HELP! Sweep frequency using Sound and Vibration Assistant

Hi,
I'm new to LabView . I want to do frequency sweep test using Sound and Vibration Assistant. I added the sweep step and chose sin wave frequency as the parameters. I selected frequency  from  1K hz to 10k hz with an increment of 500hz.
However, I do not know how to stay at one frequency for a while when sweeping the frequency.  I hope there will be 200 cycles ( or 5 minutes) at one frequency in order to get steady result.
Could anyone tell me how to set this? Thank you!
Yue

Thank you for your reply!
I am using a shaker connected to the amplifier. Attached please find the plots.
Lena
Attachments:
2015-03-27 17.16.47.jpg ‏2650 KB
2015-03-27 17.13.52.jpg ‏2657 KB
2015-03-27 17.17.23.jpg ‏2326 KB

Similar Messages

  • Need help with problem using sound and vibration examples. question repost

    I am generating a wav file using the sound and vibration example vi "SVXMPL_Wav Recorder(DAQmx)" using a ni 7422 board.  Then, using the example vi SVXMPL_Getting started with SVT(Simulated)" attempting to play back that file.  the wav file will load and play back on the graphs fine but when I click the "Play Wav File" which sends the audio to the computers speaker,  I get the error "Cannot recognise sound Format".  It plays the shipped example files fine.  I can also play the wav files I generate on a Windows audio player.  Don't know a lot about the sound and vibration toolkit or wav file formats but need to get these two to work together.  Using LV 8.5 and sound and vibration toolkit 4.0.  This is a bit of a repost of the same question ask last week but not answered.  Thanks

    Did you see Coq Rouge's reply in your original thread? Which thread are you going to continue?

  • I am using sound and vibration assistant 7.0. I want to know if it is possible to convert the mag and phase plot to real and imaginary plots ??

    I am using sound and vibration assistant 7.0 . I am using the impact test example given . I want to know if it is possible to convert the magnitude phase plot to real and imaginary plot in the sound and vibration assistant 7.0 ???

    If you have LabVIEW, you can create a user step to perform the conversion in version 7.0. Sound and Vibration 2009 has a checkbox in the Frequency Response configuration page to export the real and imaginary components. Short of upgrading SVT, you can also install the evaluation version of NI LabVIEW SignalExpress 2009, and this will also upgrade the Frequency Response Step which is shared between the two products (but then you don't get all the other features that were also added in SV 2009).
    Here are some links that may be useful to help decide whether you want to upgrade:
    http://www.ni.com/soundandvibration/
    http://www.ni.com/labview/signalexpress/
    Doug
    NI Sound and Vibration

  • Average multiple signals together in sound and vibration assistant

    Hello,
    I would like to average octave analysis data from multiple microphone channels together to obtain a single set of octave analysis data to view within Sound and Vibration Assistant (a surface average from the microphones).  I have created an octave averaging vi in LabVIEW to run in SVA, but I get the error that there are no signals in my SVA project to input into my vi.  I have based the input of my vi on code generated from SVA which outputed multichannel octave analysis data, so I don't quite understand why the output from an octave analysis in SVA doesn't match up to the input of my vi.
    I also would like to do this for multichannel power spectrum data, and I have tried creating my own vi for this as well with no success.
    I am using LabVIEW 2011 32-bit along with Sound and Vibration Assistant 2011.
    Any assistance with finding a solution to this problem would be greatly appreciated.
    Thank You,
    Eric Morgan
    Attachments:
    Octave Average.vi ‏13 KB
    Power Spectra Average.vi ‏13 KB

    Hello Jake,
    Thank you for responding to my post.  After recording the raw sound pressure data from my microphones, I placed an Octave Analysis step and a Power Spectrum analysis step in the playback section of SVA, and the outputs of these steps should have served as inputs to the VIs I created (I assume you only looked at the power spectrum averaging VI, as the octave averaging VI accepts a 1D array of clusters of center frequencies and band powers).  I did find that my averaging VIs did not have the correct size of empty array going into the second For loop, so I have corrected this in the attached VI (for averaging the FFT).
    Also, I was able to get my corrected VI for averaging the FFT to work after getting past a little quirk in SVA.  After browsing to my VI in setting up the "Run LabVIEW VI" step, I had to click the "Refresh VI" button before it would let me select a power spectrum as its input.
    I also think I figured out why the octave averaging VI doesn't work.  I think it has something to do with the fact that the output of an Octave Analysis step in SVA can not be used as an input to any other steps within SVA, which makes sense most of the time since once you have performed an octave analysis, there is really no other processing of this data that would ever need done...except for my case of averaging the 10 channels together to obtain the surface average SPL (kind of important when testing according to ISO3744).  If this is the case, I would consider this a bug in SVA, as any output from any step in SVA that can be displayed should be able to be used as an input to a "Run LabVIEW VI" step.
    I agree with you that in the end, it would be easier to do everything in just LabVIEW if I were just collecting data for post-processing at a later date, but when investigating noise issues and collecting mounds of data in the process, SignalExpress makes it a little easier to sift through that data as it is collected/logged while still in our sound lab, which may give us some ideas of different ways to test at that moment and possibly find the cause of our noise issues.
    Thanks again for responding to my post,
    Eric Morgan
    Attachments:
    AverageFFT.vi ‏19 KB

  • How can I read in a TDMS file into Sound and Vibration Assistant

    I have recorded a signal from 2 channels from a PXI 4496 DAQ card. I recorded this signal with the TDMS file format from a VI in Labview. I would like to import these signals into the Sound and Vibration Assistant for freq. analysis. In sound and vibration assistant there is an import logged tdms from signal express but I can not seem to import my original signal?  How can I import this data? 

    Hello All,
    I am trying to read TDMS file using LABVIEW. The TDMS file is created by me for reading data from one wire devices.
    I have created simple vi. attached below which read data from TDMS file. I am able to read other tdms files, I have with this program but not which one created by me. I am not able to attach file with .tdms exentiont. So I have attached it with .xlsx extention. Can anyone please guide me where is the problem in TDMS file? Am I missing anything while creating it?
    Thanks
    Attachments:
    EditTDMS (1).vi ‏14 KB
    data.xlsx ‏17 KB

  • Frequency response - sound and vibration

    Hi,
    I need to find the frequency response of the DUT. I am using the NI example from sound and vibration toolkit to do
    so (LabVIEW 8.5\examples\Sound and Vibration\Getting Started\SVXMPL_Getting Started with Swept Sine (DAQmx).vi) now my problem is
    to tabulate the phase difference between the stimulus and response when i do it i get constant values. Even though i dont give any response 
    signal to the channel i get the wave same as stimulus, is it suppose to be like that !!!!!!!!!! I will attach my vi so that it gives the idea where 
    i am measuring the phase difference pls check it and help me with this.....thank you in advance.
    Attachments:
    DAQ Freq resp (req)_trial.vi ‏121 KB

    What is the DAQ card you are using for executing this Frequency Response?
    This DAQ error is related to the output frequency of your signal higher than the possible output rate of the card. Basically, you are trying to update at a rate higher than the capability of the card.
    For doing Frequency response, generally you need to have a NI DSA card (446x/447x/449x) with one Analog output and two analog inputs (minimum). Generate the swept sine signal from the Analog output channel, give this signal as input to your DUT and also to one of the Analog input channel. This input to your Analog input channel will act as your Reference signal. Then the response signal from your DUT, connect it to another Analog input channel. You would get a very good response results.
    The reason why you need to have a DSA board is that, for doing Frequency response, we need to acquire both high frequency and low frequency components without much loss. This is possible only if your DAQ board has a higher dB value (in the range of >110dB) which is present only in DSA boards.
    I have completed a Frequency Response Analysis just a week back with the same example programs. So there wont be any problem with that vi.
    Regards,
    Sundar Ganesh

  • Where is the asper measurement in Sound and Vibration assistant

    I did a test drive of the Sound and Vibration Suite, liked what it could do, but could only afford the Toolkiit. Now I can't find the Asper (Roughness) measurement in the Toolkit. Is it there? I found the Loudness, Sharpness, etc.

    Hi elrathia,
    I think you are looking for the Sound and Vibration » Sound Quality » SV Aures Roughness function.  It should be included with the toolkit.
    Kyle B  |  Product Support Engineer  |  ni.com/support

  • How to sweep acceleration with sound and vibration toolkit?

    I need to test a device on a speaker.
    From the result before, it seems that the acceleration of the device on the speaker is an interesting parameter, so I want to keep the vibration frequency constant (sine wave) and change the max acceleration, how can I do it?
    Thanks a lot!

    Hi Golfpaul,
    could you please post your VI or a screenshot of your VI to see how your output signal is created.
    Regards
    Lars

  • I need help with Lightning using Exchange and Postbox

    Hello,
    I have Postbox for Mac v 3.0.11 and I would like to use Lightning for Exchange.
    I cannot find any support for v 3.0.11.
    Can anyone help?
    Regards
    SD

    Did you see Coq Rouge's reply in your original thread? Which thread are you going to continue?

  • Sound and Vibration toolkit for vibration analysis

    Hi guys! I am new to Labview. I am trying to use Sound and Vibration toolkit to analyse the accelerometer signal mounted on a motor through myRio. The analysis are spectral map, order tracking, power spectrum, order spectrum etc. But nothing can be seen from the output graph. The only result I get is from vibration level.
    Attached is a screen shot of my vi and actual vi file. Am I doing it correctly? I really need your help guys....
    Thanks.
    Attachments:
    Vib.vi ‏384 KB

    SK,
    You have serious problems in your File.VI.  Why are your writing to your file and then reading it right back?  Worse, there is no guarantee that the File write will actually occur before the File Read.  You have a race condition set up there between those two Spreadsheet File VI's.
    If you want to maintain a history of whatever has already been written to the file, you should be building it into an array and storing in a shift register.  Even if your File.vi would by chance work the way you want it to, storing data in the file system is much slower than maintaining your data in memory.
    As for your while loop, it is going to run as fast as it can with respect to all the functions occurring inside of it.  Is it possible you are getting 14 iterations of that while loop for each frequency step that is occurring?
    Message Edited by Ravens Fan on 07-25-2009 01:35 AM

  • The problem of sound and vibration assitant wiht labview 8.6

    when importing lavview vis into the sound and vibration assistant,  i got the error as follows:
    LabVIEW:  The software installed on this computer does not support the file format you requested. The Storage VIs access files through plug-in libraries LabVIEW and DIAdem install. Visit ni.com to download the library you need.
    how can i solve it?

    Can you please describe the procedure you are following to reproduce this error?
    File>>Import can be used to import snapshots from other projects or logs from other projects or (*.tdms) files.
    The 'Run LabVIEW 8.6 VI' Step can be used to run LabVIEW VIs from the Sound and Vibration Assistant. Consult the help as there are a number of steps that must be followed to use this feature.
    Does your VI perform file I/O? What versions of Sound and Vibration Assistant are you using? Can you post your project and built LabVIEW VI?
    Doug
    NI Sound and Vibration

  • Sound and vibration

    We are trying to capture friction noise / sound of the Gear Mesh during rotation is it possible get the output result into Micro-radians. We appreciate your kind help.
    Thanks
    BLAK

    Hi JHess,
    the Sound and Vibration Assistant is installed with NI Sound and Vibration Measurement Suite and NI Sound and Vibration Toolkit.
    You can download only the most recent version from the site that is 7.0.
    You can download this version at this link and use it in evaluation 30 days.
    Best regards,
    Serena M.

  • How to implement a psophometric filter in Labview software without uising Sound and vibration toolkit?

    Someone know the method to implement a psophometric or weighted filter in Labview software Without using Sound and Vibration Toolkit?
    Thanks

    The simplest way to implement a psophometric filter is to use the Sound and Vibration toolkit.
    Anyway if you don't want to purchase it, you can have a look at this forum discussion and this one.
    Serena Monti
    Applications Engineer
    National Instruments

  • Dsp module with sound and vibration

    Is possible to be employed with Sound and Vibration at the DSP module??
    Thank you

    Sorry,
    it's not possible to use Sound and Vibration functions with DSP. But here you can find a list of all the function you can use in DSP enviroment:
    http://www.ni.com/pdf/products/us/2005_5416_821_101_D.pdf
    Clara
    AE Manager
    NI Italy

  • Need help finding Sound and Vibration Toolkit Example Files

    I need help finding some Sound and Vibration Toolkit Example Files?
    http://www.ni.com/white-paper/3779/en
    From this link you get:  getting_started_otb.llb
    The missing files are:
    OAT Truncate Time Indices.vi
    Speed profile.ctl
    oa_Config Time or RPM Segment.vi
    svl-Complex Datatype Default.vi
    Running Windows 7, LabVIEW 2011, 32bit
    Sound and Vibration Measurement Suite
    Sound and Vibration Toolkit
    Thanks,
    -SS
    Solved!
    Go to Solution.
    Attachments:
    License S and V.png ‏4 KB

    SS,
    You can find these files here:
    C:\Program Files (x86)\National Instruments\LabVIEW 2011\vi.lib\addons\Sound and Vibration\Order Analysis\Resample Order Tracking\SubVIs
    C:\Program Files (x86)\National Instruments\LabVIEW 2011\vi.lib\addons\Sound and Vibration\Order Analysis\Tach Process\SubVIs
    C:\Program Files (x86)\National Instruments\LabVIEW 2011\vi.lib\addons\Sound and Vibration\Order Analysis\Resample Order Tracking\SubVIs
    svl-Complex Datatype Default.vi changes to svc-Complex Datatype Default.vi
    C:\Program Files (x86)\National Instruments\LabVIEW 2011\vi.lib\addons\_NISVFA\_Shared subVIs\Common
    Make sure you are license activated, and you will have to dig through the *vi and relink a subvi.
    Then you should get a white arrow.
    -SS 

Maybe you are looking for

  • Cannot add multiple members of a failover cluster to a DFSR replication group

    Server 2012 RTM. I have two physical servers, in two separate data centers 35 miles apart, with a GbE link over metro fibre between them. Both have a large (10TB+) local RAID storage arrays, but given the physical separation there is no physical shar

  • Method expression syntax error in jsp jsf 2.0 eclipse

    hi i made a simple bean jsp project, n ussed el to call methods in backing bean n show some text on the basis of method called.... the project works perfectly fine, but theres a small issue, that eclipse jsp editor marks the expression as red n shows

  • How to call a procedure in htp.tableData

    How can i call a procedure in htp.tableData. I have a procedure which draws a table. now i want to call it in a htp.tableData tag. I have a workaround like this: htp.print('<td>'); callProcedure; htp.print('</td>'); so it is working, but there must b

  • Table for Storage location name..

    Hi frnds, I have a storage location number.. Now how do i find the name or Description for that? How to find the table? ,, If anybody knows the table name plz let me know.. Thank you. Sree.

  • Changing hard drive when upgrading from 10.3 to 10.4

    When I finally upgraded the OS I decided to switch to a different drive that had a lot more room and I wanted to leave my 10.3.9 setup intact in case there was a problem and I had to go back. It didn't occur to me that my email ID files and bookmarks