Need infn about models in webdynpro

hi i am fresher i have no ideaa about models
can any body help me to find out all details about models(adaptive rfc model)
regards,
vani gaonkar

Hi,
Check the following applications,
BAPI Application:
https://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/docs/library/uuid/d352a790-0201-0010-5082-b1a608d22b6c
https://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/com.sap.km.cm.docs/library/webdynpro/wd%20java/wd%20tutorials/creating%20a%20web%20dynpro%20application%20accessing%20abap%20functions.pdf

Similar Messages

  • Need infn about how to create reports in webdynpro

    hi
    pls help me to solve asset utilization
    scenario:
    there are 3 types of assets(laptops/desktops/servers)
    there are 3 shifts
    i need to infn from swipe card/access card
    i should calculate  asset utilization
    will u pls explain me the procedure
    which toll i can go
    for
    is it possible in webdynpro to create reports with bar charts
    thank u

    Hi Vani,
    *Its possible to create a reports and Charts in Webdynpro Java.
    *There are lot of UI element funcationalities are available in webdynpro Java.
    *See this link,
    http://help.sap.com/saphelp_nw04/helpdata/en/5c/1b76bc3da0504e8b535cf3e154eaa7/content.htm
    *you can store your asset information from R/3 and bring those data
    into Webdynpro java by using adaptive RFC model.
    *Please visit this link,
    <a href="https://www.sdn.sap.com/irj/sdn/go/portal/prtroot/docs/webcontent/uuid/28113de9-0601-0010-71a3-c87806865f26?rid=/library/uuid/49f2ea90-0201-0010-ce8e-de18b94aee2d">Webdynpro Sample Applications ans Tutorials</a>
    Regards,
    Ramganesan K.

  • Need documentation about "Model Driven Development within SAP Netweaver"

    Hi All,
    in my dissertation there is a topic called "Model Driven Development within SAP Netweaver" and I am looking for documentation (literature) pointing on this.
    I'd prefer internet sources since I don't have time to order a book anymore.
    Thanks, Johannes

    https://www.sdn.sap.com/irj/sdn/advancedsearch?query=modelDrivenDevelopment&cat=sdn_all
    Regards

  • Need infn about bussiness Graphics UI Element in Webdyn Pro

    hi Experts,
    I am using Bussiness Graphics UI Element in Webdyn Pro
    chart type is Lines
    this graph is to show utilization of asse for some period say 1 month
    there will be 2 data series Utilization and Unutilization
    when i place curser near point uwe see in points in line chart i should show value for that node
    ex:
    utilization% for machine 1 is 30% on day1
    when i place curser on that point it should give me utilization%(ex30)
    how can i achieve this
    pls suggest me its urgent i have to finish it by monday
    is there any coding pls send me
    or any property we have to set in chart design
    which property
    thanks

    Hi,
    Check the following links,there are some materials....
    http://help.sap.com/saphelp_nw70/helpdata/en/ed/258841a79f1609e10000000a155106/frameset.htm
    Workout below Application,
    <a href="https://www.sdn.sap.comhttp://www.sdn.sap.comhttp://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/com.sap.km.cm.docs/library/webdynpro/wd%20java/wd%20tutorials/using%20business%20graphics.pdf">Using Bussiness Graphics</a>

  • Need infn about vc

    hi
    i am creating report using vc
    i want to populate values from rfc
    i mapped input paramers
    and output parameters of rfc
    values are not populating what could be the reason

    Hi Vani,
       You must have missed the coding for Binding. Place the below code in DoInit() method of Component Controller, in your application.
    Note : Edit it according to your application.
    Bapi_Flight_Getlist_Input bapin = new Bapi_Flight_Getlist_Input();
        wdContext.nodeBapi_Flight_Getlist_Input().bind(bapin);
    try
              wdContext.currentBapi_Flight_Getlist_InputElement().modelObject().execute();
              wdContext.nodeOutput().invalidate();
        catch(Exception e)
    Regards ,
    Prabhakar.

  • Need help about Hidden Markov Model model

    I want to make classification for EEG signal using Hidden Markov Model
    algorithm based on neural network.
    plz need help about how to implement this algorithm using LABVIEW.
    if not I want another thing to make classification.
    any one know information about this topic, send me a reply
    thanks

    Have you derrived the HMM that you want to implement?
    If so, post the algorithm and we can provide comments on how to implement it using LabVIEW.
    Message Edited by Ray.R on 04-12-2010 12:54 PM

  • Need infn abt how to start with webdynpro in netweaver?

    hi
    i am fresher i need infn abt how to start up withg webdynpro
    pls send me links where i get all studu materials
    thank u

    Hi,
    There are lot of learning Tutorials are available in sdn itself.
    I suggest these links,
    <a href="https://www.sdn.sap.com/irj/sdn/go/portal/prtroot/docs/webcontent/uuid/28113de9-0601-0010-71a3-c87806865f26?rid=/webcontent/uuid/8921447c-0501-0010-07b4-83bd39ffc7be">Getting Started</a>
    <a href="https://www.sdn.sap.com/irj/sdn/developerareas/webdynpro">Webdynpro Java</a>
    <a href="https://www.sdn.sap.com/irj/sdn/go/portal/prtroot/docs/webcontent/uuid/28113de9-0601-0010-71a3-c87806865f26?rid=/library/uuid/49f2ea90-0201-0010-ce8e-de18b94aee2d">Webdynpro Sample Applications and Tutorials</a>
    Regards,
    Ramganesan K.

  • Java.exe Error while creating the Model in Webdynpro

    Hi,
    I am creating the Model in Webdynpro Project. I have given the SAP r3 user id Passord details. after giving these details and clicking on next, it is giving an Error as " *Javaw.exe has  got  some problem needs to close. sorry for the inconvenence*". NWDS is getting closed if I click on Ok in the Pop-up window message.
    I did re install the  NWDS as well. but still the  problem is persisting. and not able to proceed further.appreciate the quick resolution .
    Rajyalakshmi
    09739066796

    hi
    This error occurs mainly due to the reason that particular plugin is not there in the NWDS.
    So please try to reinstall the NWDS or try tracing out whether that particular plugin is there or not.
    Thank,
    kris

  • I need information about Web dynpro ABAP Exception : ICF Service Node

    I need information about Web dynpro ABAP Exception :
    ICF Service Node "/sap/bc/webdynpro/sap/abcd/undefined" does not exist.
    Here abcd is application name.
    ICF Service Node exists and activated but kindly let me know from where "undefined" is coming .
    Please let me know your comments /views about  this.

    Hi,
    I think ur webdynpro service is not active after upgradation.
    You have manually activate it.
    Go go Tcode SICF,Execute the Initial screen,
    and in this new screen give service  as your application name and click on filter.
    You will get your service below which will be ur application name .
    right-Click on the deactivate and activate it or just activate it,.
    This shd work

  • Importing Java Bean Model in Webdynpro Development Component

    Hi All,
    Is there any simple tutorial, example  to import java bean model in webdynpro development component.
    I am using NWDS 7.0 SP14 and WAS 7.0.
    it really helps if you can  provide simple EJB as a development component with details how to create a public part and using this bean as java bean model in Webdynpro development component.
    what are the steps to be followed with precautions
    Thanks in Advance,
    Murali

    Hi,
    [Using the Java Bean Model in Web Dynpro|https://www.sdn.sap.com/irj/sdn/go/portal/prtroot/docs/library/uuid/4072c0d0-c21e-2b10-ab84-e2c183d355de]
    [Using EJBs in Web Dynpro|https://www.sdn.sap.com/irj/sdn/go/portal/prtroot/docs/library/uuid/1f5f3366-0401-0010-d6b0-e85a49e93a5c]
    you will get more if you search in the forum.
    more help on EJB's
    Re: Help needed in EJB
    http://help.sap.com/saphelp_nw70/helpdata/EN/19/f9bc3d8af79633e10000000a11405a/frameset.htm
    https://www.sdn.sap.com/irj/sdn/go/portal/prtroot/docs/library/uuid/70929198-0d36-2b10-04b8-84d90fa3df9c
    https://www.sdn.sap.com/irj/sdn/go/portal/prtroot/docs/library/uuid/1f5f3366-0401-0010-d6b0-e85a49e93a5c
    PradeeP

  • Need Information about templates provided by SAP to Lumira

    Hi,
    I would like to know if SAP provides any templates or pre built models (like BI content) that can be readily used by SAP lumira. If so, I need details about those models or templates or any related information.
    Thanks

    Hi,
    If i'm not mistaken, you asked the same question via the support inbox?  To re-iterate again: 
    At time of writing there is no ‘pre-built’ business content within Lumira.
    This is because it is positioned as being a ‘free form’ self-service data-discovery & visualisation
    tool, so “time to value” is very quick, and authored content can often be perceived as ‘scratch and burn’ . (apart from published/shared infographic stories)
    Yes, there are some samples in-built into the application for evaluation purposes.
    And the Cloud/Server solutions also have “Did you Know” and “Auto Discovery”
    features which generate visual content ‘on the fly’.
    Finally, there are some ‘Rapid Deployment Solutions’ (which are bundled ERP solutions for specific market industries), and I believe they do deliver some templates for content, but it would be specific to that enterprise license.
    Regards,
    H

  • Need Information about More ports Fiber Optic Switches

    Hiii Guys,
    I need information about which Cisco Switch consist more Fiber Optic Ports. I knew one model Cisco (WS-C3750G-12S-E) Catalyst 3750G-12S-12 Gigabit Ethernet SFP ports. But we can using this we can make stacking up to 9 devices. Even though I need more than 12 ports in single device. Could any one help me out in this.

    Hi Sayed,
    Please take a look at the 3560E-12SD:
    http://www.cisco.com/en/US/prod/collateral/switches/ps5718/ps7078/product_data_sheet0900aecd805bac22.html
    [edit] Sorry, didn't catch from the first post reading that you've considered stacking (the 3560 doesn't support stacking).
    For more than 12 fiber ports on a single device you'll need to go for the 4500 series with the appropriate modules:
    http://www.cisco.com/en/US/products/hw/switches/ps4324/prod_models_comparison.html
    Cisco Catalyst 4500 and 4500-E Series Line Cards
    http://www.cisco.com/en/US/prod/collateral/modules/ps2710/ps5494/product_data_sheet0900aecd802109ea.html
    WS-X4418-GB Cisco Catalyst 4500 Gigabit Ethernet Module, server switching 18 ports (GBIC).
    BR,
    Mohammed Mahmoud.

  • Importing Complex JavaBean model into WebDynpro

    Hi,
    I am trying to get Data from the EJB, in my Case, Command Bean to WebDynpro.
    So i followed this thread:
    <a href="/people/balaramnaidu.bankuru/blog/2006/04/23/importing-complex-javabean-model-into-webdynpro-by-creating-relationships-for-the-model-classes in WebDynpro</a>
    But one thing does't work here:
    I can't import the Complex type java.util.Collection.
    But i need to get Data from a DB-View into my WebDynpro.
    Is there any other chance to do that?
    Here a CodeSnippet from my Command Bean Class:
    public BusinessDelegate() throws CreateException
              try
                   Context ctx = new InitialContext();
                   OracleSessionLocalHome home = (OracleSessionLocalHome)ctx.lookup("localejbs/OracleSessionBean");     
                   session = home.create();
              } catch (Exception e)
                   e.printStackTrace();
         public void getAllOracleDetails()
              try
                   OracleDTO helper[] = session.getOracleData();
                   oracleDetailsList = new ArrayList();
                   for (int i = 0; i < helper.length; i++)
                        oracleDetailsList.add(helper(i));
              } catch (Exception e)
                   e.printStackTrace();
    OracleDTO is my HelperClass, where i made all Variable-Declarations I need in the View.
    Any ideas?
    Would appreciate that!
    Bernd

    You are not unable to import collection type means u are not able to see that variable in attribute list while importing the model?
    This may be due to you have not added getter and setter function for that collection type.

  • Create Wire Model in webdynpro FPM.

    Hi Friends,
    Please , Help Me How to create Wire Model by Webdynpro FPM. Please Give me Step by Step  process.
    i have done Form, list, search and Tree but i am not geting how to do Wire Model. So Please Give me Step by step Review to create Wire Model with FPM.
    it's Urgent.
    Thanks.
    Pappu  Mehta
    Edited by: Pappu Kumar Mehta on Nov 18, 2011 3:38 AM

    Wire Model
    The wire model can be used to create running FPM application by pure configuration or at least with minimal coding effort. The runtime interdependencies between UIBBs are defined by configuration entities called “wires” which are based on reusable “connector” classes implementing the dependency semantics. The primary use cases for the wire model are object models with generic access interfaces (for example, ESF, BOPF, or BOL).
    A wire controls the runtime interdependencies between two UIBBs; that is, they determine the data content of the target UIBB depending on user interaction changing the “outport” of the source UIBB. Outports can be of type lead selection, selection or collection. For example, the execution of a search on a Search GUIBB will change its collection outport and may therefore change the data content of a result list displayed in a separate List GUIBB. Similarly, changing the lead selection in a list of sales orders may change the data content of another list displaying the associated sales order items.
    In order to be part of a wire model, a UIBB needs to implement a certain Web Dynpro interface which in turn provides a feeder model implementation. The FPM GUIBBs are automatically integrated if their feeder classes implement the feeder model interface.
    Application areas or object models define their own namespaces for which their connector classes, feeder model classes can be reused. Moreover, they typically need to provide a transaction handler class which manages transaction events like save, modify or check and global message handling.
    Wires are defined on the level of the floorplan configuration. For each model UIBB contained in the floorplan configuration, a source UIBB with specified outport can be defined. Furthermore, a connector class and, potentially, connector parameters must be maintained.
    If the floorplan contains composite components (tabbed components), the model UIBBs contained in the tabbed components can also be wired. However, in order to provide better reusability of composite components, it is also possible to define intrinsic wiring for tabbed components. A tabbed component can define a model UIBB as a “wire plug” (this is usually a master UIBB), which serves as an entry point for the wiring of the tabbed component from the enveloping floorplan component. If a wire plug is configured for a tabbed UIBB, only the wire plug UIBB can be wired from outside.
    Transaction Handler class
        The transaction interface provides methods for handling global and transactional events. In the FPM configuration editor, one transaction handler implementation can be assigned on the level of the wire model. However, it is not mandatory to specify. But it can be used for wring some specific logic for Application level events.
    Interface “IF_FPM_WIRE_MODEL_TRANSACTION” is implemented for creating transaction handle class.
    Method
    Method description
    START
    It is called at the starting of FPM application. It provides 3 things “FPM Massage manger instance”, “Property bag of FPM Application”, and “Runtime information of FPM”.  Here, we can also specify application commit capability.
    AFTER_FLUSH
    This method is called after FLUSH has been called for all current UIBBs. It can be used to flush buffers.
    AFTER_PROCESS_EVENT
    This method is called after PROCESS_EVENT has been called for all current UIBBs. It can be used for handling transactional events for example SAVE or CHECK. Moreover, it can be used to collect messages which here not handled inside UIBBs and to forward them to the FPM message handler.
    AFTER_PROCESS_BEFORE_OUTPUT
    This method is called after PBO has been called for all current UIBBs. It can be used to collect messages at the latest possible point in time before screen output.
    AFTER_NEEDS_CONFIRMATION
    This method is called after NEEDS_CONFIRMATION has been called for all UIBBs. It can be used to analyze and add confirmation requests.
    IS_DIRTY
    This method can be used to indicate a dirty state for the work protection mode.
    Connector Class
        The “IF_FPM_CONNECTOR” connector interface comprises an interface, “IF_FPM_CONNECTOR_DEF”, defining the access by the FPM framework and an interface “IF_FPM_CONNECTOR_RUN” for runtime access by the application feeder model.
    The definition interface possesses a static attribute, “SV_NAMESPACE”, which should be filled with the namespace (ex. ‘FPM_DEMO’ or ‘BOL’ or user specific) in the class constructor of a connector implementation (for example in a common superclass).
    Method for “IF_FPM_CONNECTOR_DEF”
        Method
    Method description
    GET_PARAMETER_LIST
    Connector classes can be parameterized to flexibly control their runtime behavior. The parameter values are maintained for the wires in the FPM configuration editor. A parameter is defined by a name, its data type and a descriptive text.
    INITIALIZE
    With this method the connector is initialized with the parameter values. This method is called by the FPM runtime upon UIBB instantiation.
    GET_PARAMETER_VALUE_SET
    With this method, a connector implementation can provide a value set for each parameter. For example, in an object model a parameter may carry the association name. For a wire between specified UIBBs, the method may provide a list of all associations between the source and target business object node.
    SET_INPUT
    Receives an object reference carrying the actual data of the connected outport. This method is called before the UIBB‟s PBO by the FPM runtime.
    Method for “IF_FPM_CONNECTOR_RUN”
        Method
    Method description
    GET_OUTPUT
    Returns an object reference carrying the actual data to be displayed by a UIBB. This method can be called by the UIBB at PBO for example in the GET_DATA method of a feeder class.
    IS_CREATE_ALLOWED
    Returns a Boolean indicator whether entity creation is allowed. This method can be called by the UIBB at PBO to dynamically control the activation of create buttons for example to maintain the action usage parameter in the GET_DATA method of a feeder class.
    CREATE_ENTITY
    Creates and returns a data entity which can be arbitrarily typed. This method can be called by an action handler of the UIBB for example in the PROCESS_EVENT method of a feeder class.
    There are total seven methods in connector interface “IF_FPM_CONNECTOR” that should be implemented in connector class. We should also create class constructor for setting “Namespace”. “SET_OUTPUT” and “GET_OUTPUT” is bridge between FPM components, so these methods should be implemented properly.
    Wire for Free UIBBs
        Wire model is implemented on Web Dynpro component by implementing “IF_FPM_UIBB_MODEL” Web Dynpro interface. It contains only one method “GET_MODEL_API” which is used to set “FPM Feeder Model” for Free GUIBBs. It contains only one parameter “RO_FEEDER_MODEL”. So, we have to create a FPM Feeder Model class and assign to that parameter.
        FPM Feeder Model Class – Interface “IF_FPM_FEEDER_MODEL” is implemented for creating Feeder Model Class.
        Method for “IF_FPM_ FEEDER_MODEL”
        Method
    Method description
    GET_NAMESPACE
    Returns the namespace of the underlying application area. Method is called at design time.
    SET_CONNECTOR
    Called upon instantiation of a UIBB. It hands over the connector (reference to IF_FPM_CONNECTOR_RUN) which can be accessed for data retrieval at PBO.
    GET_INPORT_KEY
    Returns a reference to an object key which characterizes the meta data type expected at the import (for example the business object node). Method is called at design time.
    GET_OUTPORTS
    Provides a table of outports comprising the object key, the port type an identifier and a descriptive text. Method is called at design time.
    GET_OUTPORT_DATA
    Returns an object reference carrying the actual data identifier for a certain port. Method is called at runtime.
            Assistance class can also be used as Feeder Model Class and reference “WD_ASSIT” can used as Feeder model instance.
    Ex:    METHOD get_model_api .
      ro_feeder_model = wd_assist.
    ENDMETHOD.
    Wire for GUIBBs
        Nothing special we need to do that.  Interface “IF_FPM_FEEDER_MODEL” is also implemented on feeder class for getting port support. We need to set port manually using structure “IF_FPM_FEEDER_MODEL=>CS_PORT_TYPE”. It contains three constants “COLLECTION”, “SELECTION” and “LEAD_SELECTION”. It should be properly configured.
    Source Codes:
    Code for Transaction handler class:
    class ZCL_MY_TRAN_HANDLER definition
      public
      create public .
    public section.
    *"* public components of class ZCL_MY_TRAN_HANDLER
    *"* do not include other source files here!!!
      interfaces IF_FPM_WIRE_MODEL_TRANSACTION .
    protected section.
    *"* protected components of class ZCL_MY_TRAN_HANDLER
    *"* do not include other source files here!!!
    private section.
    *"* private components of class ZCL_MY_TRAN_HANDLER
    *"* do not include other source files here!!!
      data MO_MSG_MAN type ref to IF_FPM_MESSAGE_MANAGER .
    ENDCLASS.
    CLASS ZCL_MY_TRAN_HANDLER IMPLEMENTATION.
    * <SIGNATURE>---------------------------------------------------------------------------------------+
    * | Instance Public Method ZCL_MY_TRAN_HANDLER->IF_FPM_WIRE_MODEL_TRANSACTION~AFTER_FLUSH
    * +-------------------------------------------------------------------------------------------------+
    * +--------------------------------------------------------------------------------------</SIGNATURE>
    method IF_FPM_WIRE_MODEL_TRANSACTION~AFTER_FLUSH.
      return.
    endmethod.
    * <SIGNATURE>---------------------------------------------------------------------------------------+
    * | Instance Public Method ZCL_MY_TRAN_HANDLER->IF_FPM_WIRE_MODEL_TRANSACTION~AFTER_NEEDS_CONFIRMATION
    * +-------------------------------------------------------------------------------------------------+
    * | [--->] IO_EVENT                       TYPE REF TO CL_FPM_EVENT
    * | [--->] IT_UIBBS                       TYPE        FPM_T_UIBB_COMPONENTS
    * | [<-->] CT_CONFIRMATION_REQUESTS       TYPE        FPM_T_CONFIRMATION_REQUESTS
    * +--------------------------------------------------------------------------------------</SIGNATURE>
    METHOD if_fpm_wire_model_transaction~after_needs_confirmation.
    *----- which event
      CASE io_event->mv_event_id.
    *----- start over
        WHEN if_fpm_constants=>gc_event-start_over.
    *----- raise confirmation request if state is dirty
          CHECK if_fpm_wire_model_transaction~is_dirty( ) = abap_true.
          APPEND cl_fpm_confirmation_request=>go_data_loss TO ct_confirmation_requests.
      ENDCASE.
    ENDMETHOD.
    * <SIGNATURE>---------------------------------------------------------------------------------------+
    * | Instance Public Method ZCL_MY_TRAN_HANDLER->IF_FPM_WIRE_MODEL_TRANSACTION~AFTER_PROCESS_BEFORE_OUTPUT
    * +-------------------------------------------------------------------------------------------------+
    * +--------------------------------------------------------------------------------------</SIGNATURE>
    method IF_FPM_WIRE_MODEL_TRANSACTION~AFTER_PROCESS_BEFORE_OUTPUT.
      RETURN.
    endmethod.
    * <SIGNATURE>---------------------------------------------------------------------------------------+
    * | Instance Public Method ZCL_MY_TRAN_HANDLER->IF_FPM_WIRE_MODEL_TRANSACTION~AFTER_PROCESS_EVENT
    * +-------------------------------------------------------------------------------------------------+
    * | [--->] IO_EVENT                       TYPE REF TO CL_FPM_EVENT
    * | [<-()] RV_RESULT                      TYPE        FPM_EVENT_RESULT
    * +--------------------------------------------------------------------------------------</SIGNATURE>
    method IF_FPM_WIRE_MODEL_TRANSACTION~AFTER_PROCESS_EVENT.
      CASE io_event->mv_event_id.
        WHEN ''.
        WHEN ''.
        WHEN OTHERS.
      ENDCASE.
    endmethod.
    * <SIGNATURE>---------------------------------------------------------------------------------------+
    * | Instance Public Method ZCL_MY_TRAN_HANDLER->IF_FPM_WIRE_MODEL_TRANSACTION~IS_DIRTY
    * +-------------------------------------------------------------------------------------------------+
    * | [<-()] RV_IS_DIRTY                    TYPE        BOOLE_D
    * +--------------------------------------------------------------------------------------</SIGNATURE>
    METHOD if_fpm_wire_model_transaction~is_dirty.
      rv_is_dirty = cl_fpm_wire_model_col_factory=>work_protection_is_dirty( )

  • Need Info about BW CRM Analytics

    Hi all,
    Guys,
    Please help me out...
    I need Info about BW with CRM Analytics
    What are the core areas where data's are extracted for CRM to BW
    What will be the Interview question related to BW CRM Analytics
    If possible if u have any docs kindly email me at [email protected]
    Thanks in Advance.
    Jaffer Ali.S

    Dear Jaffer Ali S.,
    The following types of analyses can be carried out:
    <b>CRM Lead Analysis</b>
    Use the InfoCube CRM Lead Management (Technical Name: 0MKTG_C01) for reporting.
    The Lead Management InfoCube contains all the characteristics and data used for the administration of leads. This InfoCube enables you to execute the following standard queries available in SAP BW:
    Channel Analysis
    Efficiency Reporting
    Historical Evaluation
    Lost Leads
    Channel Management: Top-n Lost Leads (Current Year)
    <b>CRM Activities Analysis</b>
    Use the InfoCube CRM Activities (Technical Name 0CSAL_C01) for reporting.
    The InfoCube for activities in CRM provides the data basis for evaluating business activities undertaken by your employees. It provides you with information about how much time is being spent on contacting the customer, whether customers actively seek out contact with your company and how intensively your employees look after your customers. It delivers data for queries such as:
    Intensity of customer care
    Activity History
    Success/failure analysis
    <b>Customer Interaction Center (CIC)</b>
    Activate the InfoCube Interactive Scripting Evaluation (IC WinClient) 0CRM_CIC1.
    Interactive Scripting Evaluation (IC WinClient)
    This InfoCube provides the data base for the interactive scripting evaluation. It supplies the data to the Interaction Center (IC): Interactive Scripting Evaluation query.
    <b>Opportunities Analysis</b>
    Activate InfoCube 0CRM_C04 - Opportunities.
    The CRM Opportunities InfoCube contains all the characteristics and data used for the opportunities analyses.
    <b>Sales Order Complaints Analysis</b>
    Activate InfoCube Complaints (Technical name: 0CSAL_C09).
    You can carry out the complaint analysis on a daily, monthly, weekly or a quarterly basis. The analysis can be done in relation to CRM Service Organization, CRM Sales Organization, CRM Product, and Sold-To Party.
    <b>Service Qualtiy Analysis</b>
    Activate the MultiProvider 0CSRVMC04 - CRM Service - Orders and Confirmations with Complaints.
    The MultiProvider 0CSRVMC04 - CRM Service - Orders and Confirmations with Complaints gets the data from the following ODS objects for analyses in various queries:
    0CRM_PROI - Orders: Item Data
    0CRM_COI - Controlling (Item Data)
    0CRM_CNFI - Confirmations (Item Data)
    0CRM_COMP - CRM Complaints (Items)
    Let me know if you need further help.
    Reward points if it helps.
    Regards,
    Naveen.

Maybe you are looking for

  • Faked (and apparently working) Apple ID. What can I do?

    I have just received three automated e-mails from Apple, on a different e-mail account from the one I signed up for this Apple ID. The first one addressed me by a woman's name (I'm a man) and said that someone had added my e-mail as a contact address

  • Update my app. What is the correct procedure for updating an app/folio?

    I designed a folio in Indesign CS6 and created an app of the folio in adobe dps and succesfully uploaded it to the app store. Now I want to update my app. What is the correct procedure for updating an app/folio?

  • Highlight the bookmarked text when clicking bookmark link?

    I have severeal bookmarks on one page of the PDF. Is it possible to have the PDF set up so that it will highlight the bookmarked text when the bookmark link is clicked? Or something that would make it easier to find the bookmarked section of the docu

  • Allow external host to relay through Ironport?

    What is the "safest" way to allow an external host to relay e-mail through our Ironport? I know it's not "recommended", but I don't have any choice. I guess I could set up the external IP that's allowed to relay in Mail Policies --> Hat Overview - Re

  • Photoshop Elements Editor Function Won't Work

    After upgrading to Windows 7, the Editior function on my Photoshop Elements 6 program stopped working. I have tried the following: Run as Administrator. No success. Compatibility Troubleshoot. No success. Reinstalling. No Success. Anyone have any sug