Need information on USB frame grabber Labview compatible (planning to buy)

Hello all,
                  I am looking USB based frame grabbers which are compatible with LabVIEW only.  I need atleast 50 frames/sec acquisition rate. I am using PULNIX P2013P analog or monochrome CCIR camera with LabVIEW 8.2 version. Please suggest me any of such frame grabbers even third party products if they are available and also only compatible with LabVIEW.
regards
visu 

There are no USB frame grabber cards provided by NI. The only form factors that are supported for frame grabbers are PCI, PCI-e and the PXI platform. If you are interested in using USB cameras, then all you need is NI-IMAQ for USB driver (the driver is not officially supported by NI) and a USB camera that is supported by the driver.
Message Edited by Adnan Z on 03-08-2009 07:42 AM
Adnan Zafar
Certified LabVIEW Architect
Coleman Technologies

Similar Messages

  • Is the NI 1426 frame grabber compatible with a Line/Linear array scanner?

    Is the NI 1426 frame grabber compatible with a Line/Linear array scanner?
    I am currently doing a feasibility study of project which uses NI 1426 frame grabber and a Linear Array Scanner, and I would like to know if they are compatible with each other.
    Thanks in advance
    Sandeeo
    Solved!
    Go to Solution.

    Hi sandeepchinni,
    I agree with gunnesjr that we need more information about what you mean by Linear Array Scanner.  Like he said if it is a line or area scan camera then yes it will most likely be compatible.  A little correction from what he said.  You do not need to purchase NI Vision if all you need to do is acquire images.  The framegrabber will come with the software that is need to work.  If you need to do any kind of image processing then you will need NI Vision.  The following knowledgebase lists what is installed with driver for the card.  Which Vis are Installed with NI-IMAQ and Vision Acquisition Software?
    Adam H
    National Instruments
    Applications Engineer

  • How can I capture live video and still image by a DirectX compatible USB webcam using LabView ?

    Dear forum members
       I'd like to design a user interface which shows a live video and capture still images for it by a DirectX compatible USB webcam using LabView or NI Vision Toolkit, how can I do this ? and If this is possible How can I reach the webcam DirectX filter properties and set them using LabView ? I would be grateful to anyone Who lead me to the correct solution.
        Sincerely
        Cem DEMiRKIR

    Cem,
        With our example programs you can acquire and save an image (IMAQ >> File Input and Output >> Snap and Save to File.vi) from one camera, if you double the VI's to create the image and the image task, you can easily have one program acquire and save for two cameras.
        I may need more information on what you mean by calibration.  Do you mean basic camera setup?  That can be done in Measurement and Automation Explorer by setting up the options within the IMAQ settings for each camera.  Or do you mean more complex calibration for special types of images?  The more description of what you mean, the better I will be able to help you get it done.  You mentioned zoom and motion parameters, what kind of motion?  Our vision drivers only control triggering the camera to acquire, then analyzing, processing and displaying the resulting image.
        If you have more details on exactly what you want to do, that would be great.  Let me know if you have more questions, thanks!
    -Allison S.
    Applications Engineering
    -Allison S.
    Calibration Services
    Product Support Engineer

  • Labview won't believe that my frame grabber board is configured?

    Thank you in advance for any help
    I am new to labview. I am sorry if this is a silly question, but I have worked on it for hours and haven't been able to find the solution.
    I am using a NI-IMAQ PCI-1422 board to aquire images from a Pulnix TM 1020 camera. I can successfully see the camera from both the MAX and IMAQ vision builder. When I go to the DAQ Solution Wizard in Labview it says that "You have no DAQ hardware currently configured," and it sends me back to the Measurement and Automation Explorer 3.0 It looks configured to me and all my attempts to configure it more fully didn't make the system happy so I don't understand what else I need to do.
    Also, where are the instrument driver VIs f
    or this? Do I already have them hidden somewhere or do I need to go and download them?
    Any advice that you could give me would be greatly appreciated.
    -Anita
    Also, in case you are bored, here is an overview of what I am trying to do. I want to write a labview program which will allow me to specify a delay in seconds and then have labview acquire a an image from the frame grabber board and save it to disk, wait the specified delay period and then acquire and save ...

    Anita,
    Since you are using an NI-IMAQ PCI-1422 board you will not be able to use the DAQ Solution Wizard. Your board uses the NI-IMAQ driver software instead of the NI-DAQ software. You will want to use the Vision VIs which can be found by right-clicking on the block diagram and selecting Functions->All Functions->NI Measurements->Vision.
    You can find some LabVIEW examples by checking your LabVIEW directory and navigating to the Examples->Vision directory. You can also find these examples by using the LabVIEW example finder by navigating to Help->Find Example
    I have attached a helpful excerpt from an online knowledge base. The full knowledge base can be found pendocument >here. Please post back if you are still having troubles!
    Craig H.
    National Instruments
    Attachments:
    IMAQ_Quick_Example.GIF ‏24 KB

  • I'm looking for a digital picture frame that is compatible with the iPhone 5 and 4S.  I was looking at the Panasonic MW-20 but from what I can see I don't think it is.  Any information would be great!  Looking to buy a replacement frame for Christmas.

    I'm looking for a digital picture frame that is compatible with the iPhone 5 and 4S.  I was looking at the Panasonic MW-20 but from what I can see I don't think it is.  Any information would be great.  Looking to buy a replacement for Christmas.  Thanks!

    Hi - the new lightning connector on the iPhone 5 has an authentication chip so very few 3rd party manufacturers have come out with compatible devices - so I doubt that you will find a frame that works for both phones - however Apple has come out with 2 apapters - one is a cable and one is a direct 30 pin to lightning device - you would have to check out each frame to see if one of these might work - I looked at the Panasonic and it looks promising but I would check the return policy of anything that you buy in a case it doesn't work.

  • I need a wireless usb adaptor for a Power Mac G4... any suggestions? (needs to be compatible)

    I need a wireless usb adaptor for a Power Mac G4... any suggestions? (needs to be compatible)

    With Mac OS X 10.3 or higher, a number of USB Wi-Fi adapters would be possible to use. However, for an earlier operating system, a wireless Ethernet bridge (such as the examples below) can be a better (and sometimes the only) option. A wireless Ethernet bridge does not normally require special drivers, and can thus be used with almost any Ethernet-equipped computer.
    http://www.netgear.com/landing/wnce2001.aspx
    http://support.linksys.com/en-us/support/bridges/WET610N
    Jan

  • Video acquisition from frame grabber

    I wanted to acquire image from a video camera which only has analog output. To do that, I used a framegrabber, called :"Hauppaugel analog video giditizer".
    However, as I can see from the list, the framegrabber provides image with YUY 2 format and in the list of my Labview vision module, I could not find such type.
    I have written a code for acquiring image which works fine with normal web cameras. however, when I want to use it for acquiring the image from frame grabber, it gives following errors:
    1. Error code: 1074396120 Not an image
    2. Error code: 1074396015 Cannot connect to camera, it may be in use.
    I guess it has something to do with the formats of the picture, but I really don't have experience with that. Could you help me out? The code is attached.
    I lookforward to your advice and thank you in advance for the help.
    Attachments:
    usb-acquire-avi22.vi ‏69 KB

    Hello,
    First, you have to know that your camera must be Direct Show, otherwise, you won't be able to use it in LabVIEW.
    If it is compatible, then you will be able to grab image using IMAQ USB, but keep in mind that this set of VI is no longer supported as IMAQdx is fully compatible with DirectShow cameras, and much better than IMAQ USB.
    Regards

  • NI PCIe-1433 Camera Link frame grabber programming using VC++

    Hello, I have a Basler Camera Link-compatible camera and they use the NI PCIe-1433 Camera Link frame grabber as the image acquisition device.
    Right now, I want to develop some applications on that camera and need to do programming on the NI PCIe-1433 by VC++.
    So I want to know where I can find the software development kit for the NI PCIe-1433. For example, I can control the camera to grab the image by using the different functions(such as imgGrab(), or somthing like that ) from that software development kit.If there are some sample code that would be better.  

    Hi Wrsbj,
    The IMAQ functions that you mentioned are contained in the IMAQ driver, which is used to acquire from Camera Link frame grabbers. I would also check the compatibility chart, to make sure that you get the version you need. As for example programs, you can take a look at this KnowledgeBase article concerning building and running the IMAQ examples in VC++.
    David S.

  • Control exposure time and gain with FPGA as frame grabber

    Hi,
    I'm using a Basler acA2000 340kc camera with a PCIe1473R FPGA as frame grabber.
    I managed to obtain images succesfully by modifying some of the sample codes. I can also control some of the camera settings thorugh the Pylon software.
    Nevertheless, I'd like to control the exposure time and gain in   LabView.
    Any idea on how to do this?
    Thanks

    Ultimate the serial port on the board is controlled by the code on the FPGA. There are shipping examples that provide the FPGA-side implementation of interfacing the serial port to a host-side interface, which then bridges it to a TCP port, which is bridged to a DLL called "clsernif.dll", which interfaces through the common "clallserial.dll" that Pylon can use to access the camera.
    Depending on your needs, you could interface at any of these layers.
    -If you need to do this with the ultimate in determinism, you could have the FPGA issue these serial commands directly as needed
    -If can do it from the host CPU, you could modify the host-side code and send/receive serial traffic to the FPGA code directly
    -You could examine the example code that bridges to a TCP port and simple write some host VIs that talk directly to it by opening a TCP session to the socket it uses.
    Eric

  • I am using PCI-6033E IO card and i would like to send 5 volts (high logic ) to the trigger box. the trigger box will trigger the frame grabber card, that i am using for image acquisition.

    i am using PCI-6033E IO card and i would like to send 5 volts (high logic ) to the trigger box. the trigger box will trigger the frame grabber card, that i am using for image acquisition.

    Hello;
    The first thing you need to figure out is the shape of the trigger pulse needed.
    In case you just need a logic high TTL pulse, you can use one of the digital lines of your DAQ device.
    In case you need a pulse train (multiple trigger pulses), you will need to configure one of the general purpose counters to accomplish that task.
    You can find examples in both Labview and NI-DAQ showing how to program your DAQ board to accomplish both approaches.
    Hope this helps.
    Filipe A.
    Applications Engineer
    National Instruments

  • Interfacing with Scion Image Frame Grabber?

    I have a Scion Image Frame Grabber in my PC & am trying to control it via LabView Vision. Scion has no LabView drivers, but has a dll & SDK available. However, their driver expects C++ pointers as arguments & returns ptrs. My thought is to write a cover driver in C++ to shield labview.
    Anyone have drivers for this, or experience with this frame grabber board?

    Thank you for posting on the forums. While National Instrument's driver and native IMAQ support obviously does not interface to third party boards, if your board does include a dll that allows you to control the frame grabber then you may be able to get the board working in LabVIEW. LabVIEW has a few options available for calling dlls, and this is probably the route you will want to go, unless another user already has a driver for this board and LabVIEW available.
    To get more information on calling dlls and interfacing to external code (particularly C/C++ code), then I would start by looking at the "Using External Code in LabVIEW" document. You can find this by opening LabVIEW, going to the Help menu, and clicking on "Search the LabVIEW Bookshelf..." This will ope
    n a pdf document that links to other great resources, one of which is the large "Using External Code in LabVIEW" document. Glance through this manual and then other information/examples on ni.com/support for some help in getting starting in calling DLLs from within LabVIEW if you have never had experience with this before.
    Regards,
    Michael
    Applications Engineer
    National Instruments

  • IMAQ Vision Software with FlashBus MX Frame Grabber?

    Is it possible to use IMAQ Vision Software with a FlashBus MX Frame Grabber Card? In the manual I only find references to NI acquisition boards. Unfortunately I have to make do with the hardware I already have.

    Heiko,
    It may be possible, but you will need to find out if there are any LabVIEW drivers for the card.
    Vision analysis can be split into two components. The first half is getting the images into the computer with a frame grabber card. This can be done easily using NI frame grabbers, or with varying degrees of difficulty using other frame grabbers that have LabVIEW drivers.
    Once the images are in the computer, IMAQ Vision doesn't care where they came from, so it can be used to manipulate images regardless of the source.
    Bruce
    Bruce Ammons
    Ammons Engineering

  • S: cheap LabView compatible GPIB-IEEE-​488 Card

    Hi Newsgroup,
    i'm looking for a cheap GPIB-IEEE-488-Card (LabView compatible) to control a
    climate-chamber with LabView 6.i. As the climate-chamber was build more than
    ten years ago, i don't expect it's interface to be compatible to the
    IEEE-488.2 standard.
    Following information about the interface occur in the manual: IEC-bus, IEEE
    488 plug connector
    Is there a downward-compatibly form IEEE-488.2 to IEEE-488?
    Does anybody know where i can buy such a card for few money?
    I've found a Dealer in Germany (where i come from) with the following offer:
    http://www.quancom.de/quancom/quancom01.nsf/home_p​rod_deu.htm?OpenFrameSet&F
    rame=unten&Src=http://www.quancom.de/qprod01/deu/p​b/gpib_1.htm
    For me it seems to be quite inexpens
    ive, but i have few experience within
    this range. Therefore I would be glad, if you could help me. My boss would
    not appreciate if spend a lot of money for a card, which does work together
    with the climate-chamber.
    Greetings
    Florian

    Les's answer about 488 is right on. 488.2 is just a superset of the original 488 - nothing about the electrical interface has changed. You question about low cost cards has a different problem however. The GPIB functions in LabVIEW will only work with an NI card. If a vendor offers a VISA driver for their card, then the LabVIEW VISA functions will work but I have had some problems with very old instruments and VISA. If the vendor offers GPIB drivers for LabVIEW, then use those. If all they have is a DLL that you need to call, then you've got a lot of software development ahead of you. All of this means is that the cost of the hardware is just a part of the overall cost of a project. If you manage to save $100 on the board and then have spend a week or two o
    n the basic GPIB software, you really haven't saved anything.

  • After Effects CS6 error: RAM Preview needs 2 or more frames to playback - any ideas please?

    Hi everyone,
    I'm running After Effects CS6 (11.0.4.2) on a MacBook Pro 2.8Ghz with 16GB RAM (Mac OS 10.9.4)
    As a test, I created a 3 and a half minute Sequence in Adobe Premiere CS6, and then imported this into After Effects CS6, and placed it on the AE timeline.
    This footage involves a couple of 1920x1080p footage movies, some psds and a large number of JPGs exported from two videos arranged as a sequence in two layers in Premiere, one on top of the other. So all in all for a Premiere / After Effects file I'd say it's reasonably heavy.
    I then did a RAM Preview with Multiprocessing switched off - the 3 and a half minute sequence loaded into RAM, taking about 1min 30seconds, and played back in realtime at 25fps. This worked fine with 3,4,5 and 6 GB RAM available to other applications in the Memory Preferences. All things considered I think this is quite good. I can make changes, reclick the RAM Preview icon and my changes load into RAM and it previews ok.
    My only 'complaint' is how long the RAM Preview takes to load up the whole thing.
    I've been reading up on Multiprocessing and decided to try this to see if I can speed up the time it takes my RAM Preview to load up.
    So I looked at some recommendations from Adobe and read information on various forums including this one.
    My settings in the Memory Preferences are currently
    • 6GB reserved for other applications
    • Reduce cache size when system is low on memory - unticked
    • After Effects Multiprocessing - ticked
    • Installed CPUs (processor cores) - 8
    • CPUs reserved for other applications - 6
    • RAM allocation per background CPU - 3GB
    • Actual CPUs that will be used - 2
    This combination takes about 25 seconds to load up my 3 and a half minute sequence which I thought was pretty amazing.
    I then pressed the stop button and then the play button - so now just playing the sequence briefly.
    And also added a new layer - into the timeline - just a simple shape.
    Then I tried a RAM Preview again.
    I found I could load up part of the sequence but not load the whole thing into RAM.
    I kept trying to get a RAM Preview and got this message
    "After Effects error: RAM Preview needs 2 or more frames to playback" which seems to prevent RAM Preview from working.
    Eventually I quit and restarted After Effects and the problem went away temporarily and then came back when I tried again.
    I tried various changes to the Memory Preferences - trying 3GB available for other applications. This gave 13GB of my 16GB RAM to After Effects.
    This made it take slightly longer for the After Effects error to appear but it still appeared.
    I tried ticking Reduce Cache size in the Memory Prefs  - the After Effects error still appeared, so having read this is supposed to make the issue better I now leave it untucked, but as far as I can see ticked or untucked, it makes no difference, the problem remains.
    I've since tried -
    Making 2,3,4,5 and 6 CPUs available for other applications.
    Changing the Background RAM allocation per background CPU to 0.75GB, 1GB, 1.5GB, 2GB and 3GB
    Lots of combinations.
    But in the end, I always get the "After Effects error: RAM Preview needs 2 or more frames to playback" error.
    It might take less or more time for the message to show up, depending on the combination of settings, but in the end I always got the same message appearing.
    And I notice that I can RAM Preview less and less of the timeline. i.e. it becomes more blue than it does green and will load in only a small section of the timeline as opposed to the whole thing.
    Reading further, I tried Edit > Purge > Image Cache and Edit > Purge > All Memory but still get the error message.
    I also tried ensuring there were no other applications running e.g. Safari or Chrome or Firefox. And certainly not Photoshop or Premiere etc.
    Reading even further, I tried two Memory management applications - 'Memory Clean' and 'Purge.'
    Neither has had any effect - the After Effects error still appears.
    Then I went back into the Memory and Multiprocessing Preferences.
    I unticked Render Multiple Frames Simultaneously. And now the RAM Preview loads the whole 3 and half minute sequence in entirety, taking about 1 and half minutes to do so. It's working as perfectly as if I'd just quit and re-opened the application.
    Then I went back into the Memory and Multiprocessing Preferences.
    I reticked Render Multiple Frames Simultaneously.
    The chose Edit > Purge > All
    And tried a RAM Preview again. It loaded up in 25 seconds, but then, as previously, the error message came.
    I tried Edit > Purge All - no effect.
    And I tried going into the Media and Disk Cache Preferences and clicked Empty Disk Cache - still the problem remains.
    I understand from my reading that After Effects CS6 11.0.2 was intended to fix this issue but I'm on 11.0.4 and as far as I can tell, I still have it - assuming it's the same thing.
    As far as I can see, not using Multiprocessing allows me to work without these errors but take a bit longer to load the RAM Preview.
    However I'd like to be able to use Multiprocessing as it seems it can potentially speeds things up quite a lot. I realise I could just not use it and AE would work, but I'd rather be able to make use of a feature of the software if possible, especially if it will speed things up and make optimum use of the my computer's hardware.
    I've downloaded a trial copy of After Effects CC 2014. I'm still testing it but as far as I can see the RAM Preview error appears in this version of AE as well, but can take bit longer to show up in my experience.
    Thanks everyone - if anyone has any thoughts or advice I'd appreciate hearing your opinions.
    Kind regards,
    John

    You need to have much more RAM reserved for other applications and more CPUs reserved for other applications. Your current settings are crippling your performance.
    Read these:
    https://blogs.adobe.com/aftereffects/2009/12/performance-tip-dont-starve-yo.html
    http://blogs.adobe.com/aftereffects/2010/03/performance-tip-dont-oversched.html
    After you have adjusted your settings according to the recommendations on those pages, restart your computer and try again.

  • Software needed for the USB device, "USB Interface Controller TEST2.0"

    My mother recently acquired a digital camera. She acquired it from a second-hand store, which did not include an interface cable or software. The manual (and the USB port on the camera) indicates that a male-male USB cable is necessary for photos to be copied to the hard drive.
    I was not successful in locating such a cable at any local electronics store (I assume such a cable is now out-of-date). I purchased one from a seller on eBay. The brand is "e circuit electronics".
    Upon powering up the camera with the cable connected to it and the computer, the following message appeared:
    "Software needed for the USB device "USB Interface Controller TEST2.0" is not available. Would you like to look for the software on the Internet?"
    I clicked "Yes". After an approximate two-minute wait, another message appeared stating:
    "Software Update is not able to connect to the Internet. Please check your configuration and try again."
    I deleted, "Software Update Preferences" in the Preferences folder inside the System Folder, without solving the problem. How do I solve the issue of allowing Software Update to connect to the Internet?

    Thank you for your continued assistance, BDAqua. Unfortunately, the driver you linked to does not seem to be compatible with the camera. It is a driver for the V20 model, whereas my model would correspond to be a V2755, as referenced from a list of other Vivicam models when during a search at the Open Drivers web site.
    From the system requirement about the card reader you gave me, it will not work, as this system is running 9.1. I am hesistant to upgrade this computer to 9.2, as I have experienced system unstability with that version, with even the 9.2.2 update applied.
    In the mean time, I have e-mailed Vivitar regarding this issue, but have as of yet received a reply.
    I am not certain as to other specifics to give you, in order to solve the Software Update problem. Please elaborate.
    Yes eww, the computer in question is able to fully connect to the Internet for all that I need. I am fully aware of the difference between a computer connecting to the Internet, and a computer connecting to a digital camera. I have 15 years of Macintosh experience.

Maybe you are looking for

  • I need assistance my firefox is stuck in safe mode even when i already restarted everything.

    My firefox is stuck in the safe mode and i am unable to return to the regular mode. I have tried restarting as suggested but it is still in safe mode. How can i return to the regular mode?

  • Blackberry Curve 9320 - App Store Problems

    Heyo! I have a problem with my new BB. When I want to connect App World / My account i get this msg: BBID token is expired (Error ID: 40631) I registered first time my phone, so the problem's reason is not this. I also used the store at home, when i

  • 6500 Slide Text Freeze

    Hi all, I'm getting a problem with my 6500 slide, whereby the 2 blue buttons below the screen (the ones for options and clear/exit) just stop responding when I write a text message. There doesn't seem to be any common factor that causes it, the only

  • Now on 2nd DR8-A and still Problems

    I'm on my replacement drive of my replacement drive of a dr8-a and I have been less than pleased.   I get constant burn errors and underruns on dvd and cd media.  I've used no brand, name brands, and still no luck.  My pioneer a05 keeps on ticking an

  • SapScript for Purchase order

    Hi Group, I want to know SAP standard Script name and driver program name for purchase order. Thanks, Smitha.