Newly bought Nexus 1010: missing Quadport GE NIC Card.

Hello,
Thanks in advance for anyone who can help to clarify the situtation my customer has for Nexus 1010.
One of our customer bought a pair of Nexus 1010 physical appliance. One thing strange is that both Nexus 1010 do not come with 1 x Quadport GE NIC Card.
All Cisco Nexus 1010 doc says the Nexus 1010 has 2 Ethernet port (port 1 and port 2) built on mother board, and a Quadport GE NIC Card installed (port 3-6). Cisco dynamic configuration tool for Nexus 1010 does not have the option of choosing this Quadport GE NIC Card.
I am wondering why the Nexus 1010 did not have the extra card installed.
Thanks for your assistance!
Fuming

Hello Fuming,
This appears to be a mistake during the manufacturing process.  Please open a TAC case and we will process an RMA.
Thank you,
Matthew

Similar Messages

  • Nexus 1010 HA

    Hello   
    I have a problem with Nexus 1010 HA.
    I have two Nexus 1010. One is configured as Primary and the other as Secondary.
    I have a VSB (VSM type) created on both, enabled as Primary and Secondary respectively.
    HA between VSMs works fine. But HA between Nexus is not working. Something is missed. Any ideas? Thank you!!!
    Nexus 1010 - Primary
    NX-1010-TB# sh system red status
    Redundancy role
          administrative:   primary
             operational:   primary
    Redundancy mode
          administrative:   HA
             operational:   None
    This supervisor (sup-1)
        Redundancy state:   Active
        Supervisor state:   Active
          Internal state:   Active with no standby                
    NX-1010-TB# sh mo
    Mod  Ports  Module-Type                       Model               Status
    1    0      Cisco Nexus1010 Chassis           Nexus1010           active *
    Mod  Sw                Hw     
    1    4.2(1)SP1(2)      0.0                                            
    Mod  MAC-Address(es)                         Serial-Num
    1    00-19-07-6c-5a-a8 to 00-19-07-6c-62-a8  NA
    Mod  Server-IP        Server-UUID                           Server-Name
    1    10.1.30.53       NA                                    NA
    Nexus 1010 - Secondary
    switch# sh sys red st
    Redundancy role
          administrative:   secondary
             operational:   secondary
    Redundancy mode
          administrative:   HA
             operational:   None
    This supervisor (sup-2)
        Redundancy state:   Active
        Supervisor state:   Active
          Internal state:   Active with no standby                
    Other supervisor (sup-1)
        Redundancy state:   Not present
    switch# sh module
    Mod  Ports  Module-Type                       Model               Status
    2    0      Cisco Nexus1010 Chassis           Nexus1010           active *
    Mod  Sw                Hw     
    2    4.2(1)SP1(2)      0.0                                            
    Mod  MAC-Address(es)                         Serial-Num
    2    00-19-07-6c-5a-a8 to 00-19-07-6c-62-a8  NA
    Mod  Server-IP        Server-UUID                           Server-Name
    2    0.0.0.0          NA                                    NA
    * this terminal session

    Prasad,
    This means that there is some sort of a communication issue between the two Nexus 1010 switches in the control VLAN. You should probably check the upstream configuration on the ports that connect to the 1010 links carrying the control traffic and also the links involved in the control path.
    Thanks,
    Shankar

  • Nexus 1010 weird HA mechanism

    Hello guys,
    We are in the middle of the installation of 2 Nexus 1010 appliances.
    the two appliances have a failover mechanism where you have only one address for the cluster of appliance. I don't think that it is a good idea because the Vsm on the appliance already has its own HA mechanism. on the contrary, the appliance HA mechanism is confusing because you can only access by telnet the primary appliance. What if your active VSM is running on the secondary appliance? how to access Out of band to this one?
    It would make more sense to me if each appliance 1010 would be standalone?
    am I missing something here? any ideas on why we use Ha for the Nexus 1010?
    Thank you
    laurent
    Sent from Cisco Technical Support iPad App

    First of all. According to the documentation Nexus 1010 is not supported in standalone scenario.
    • The HA standalone role is not supported for the Cisco Nexus 1010.
    • Cisco Nexus 1010 is not supported in the non HA mode.
    http://www.cisco.com/en/US/partner/docs/switches/datacenter/nexus1000/sw/4_2_1_s_p_1_4_a/install_upgrade/guide/n1010_installupgrade_install.html#wp1065391
    I see the HA mechanism between N1010 as a way how to manage them. Nothing more, nothing less. N1000V on top of them do have their HA mechanism. I am able to reach standby N1010 VSM either by:
    ssh to the LOM port of the standby N1010, then connect host and then login virtual-service-blade or
    ssh to the N1010 cluster address and then login virtual-service-blade secondary
    Petr
    Message was edited by: Petr Mojzisek

  • Nexus 1010/1000v L3 Mode Through ASA

    Hi,
    A question regarding the subject line.  When deoploying redundant Nexus 1010 hardware appliances (VSM's) on the "inside" and Nexus 1000v's on your ESX hosts in the "DMZ" in Layer 3 mode which is seperated by an ASA, what VLAN's are actually need?  Both from the inside and DMZ perspective.  Specifically, do you actually need Control and Data/Packet VLAN's configured when using L3 mode.  When you configure the SVS domin for L3 Transport you explicitly negate both Control and Data/Packet VLAN's? 
    Also, when configuring the 1000v in L3 mode is it best practice to have the system vlan the same as your management vlan, and also use the same vlan for the Vmkernal NIC.  When setting up the Vmkernal NIC on the ESX host the only option available was to use the management vlan.  

    Hello Aaron,
    The Nexus 1010s only communicate in L2 mode so you'll still need control, management & packet vlans between the two appliances. VSMs deployed in L3 mode collapse the control & packet vlans into the management network.  Traffic between the VSM and ESX host will be tunneled over IP.  Therefore you need to ensure IP connectivity between the VSM mgmt0 interface and the ESX host management vmk.
    Yes, you will want to define the ESX vmk vlan as a system vlan on BOTH the vethernet & ethernet port-profiles.
    Matthew

  • Nexus 1010 boot failed

    Hi all,
    I tried to boot nexus 1010, but only cimc can login. The serial console did not show any information, and still no response. So I tried to connect keyboard and monitor, both are no response. In addition, the nic port is down too.
    Have any idea? Or who to troubleshooting it?
    Sent from Cisco Technical Support iPhone App

    Hello Padma,
    Has this server worked before ?
    -> Yes.
    Are you able to access the N1010 host CLI interface by doing SSH to CIMC IP address ?
    -> Yes.
    ssh admin@ "connect host" did not show any response, and console can not return to CIMC.
    Sent from Cisco Technical Support iPhone App

  • Need quick reply 4.2(1)SP1(5.1) on Nexus 1010?

    We have most likely run into CSCtz74514 in 4.2(1)SP1(3) in a HA Nexus 1010 setup and need to upgrade. In the downloads I can find 4.1(1)SP1(5.1) for Nexus 1010. I have read through the release notes for 4.2(1)SP1(5.1). The only VSAs talked about are Nexus 1110-S and 1110-X
    Is 4.2(1)SP1(5.1) really supported on a classic Nexus 1010 with 16GB ram or should we go for 4.2(1)SP1(4a)?
    NTM-DC-VSA-01# show inventory
    NAME: "Chassis",  DESCR: "Nexus 1010 (Virtual Services Appliance) 2 slot Chassis "
    PID: N1K-C1010           ,  VID: A   ,  SN: 1610440479132074267 
    NAME: "Slot 1",  DESCR: "Nexus 1010 (Virtual Services Appliance)"
    PID: N1K-C1010           ,  VID: A   ,  SN: QCI1533A662         
    NAME: "Slot 2",  DESCR: "Nexus 1010 (Virtual Services Appliance)"
    PID: N1K-C1010           ,  VID: A   ,  SN: QCI1533A7Q3         
    NTM-DC-VSA-01# show ver
    Cisco Nexus Operating System (NX-OS) Software
    TAC support: http://www.cisco.com/tac
    Copyright (c) 2002-2011, Cisco Systems, Inc. All rights reserved.
    The copyrights to certain works contained herein are owned by
    other third parties and are used and distributed under license.
    Some parts of this software are covered under the GNU Public
    License. A copy of the license is available at
    http://www.gnu.org/licenses/gpl.html.
    Software
      loader:    version unavailable [last: loader version not available]
      kickstart: version 4.2(1)SP1(3)
      system:    version 4.2(1)SP1(3)
      kickstart image file is: bootflash:/nexus-1010-kickstart-mz.4.2.1.SP1.3.bin
      kickstart compile time:  7/8/2011 18:00:00 [07/09/2011 04:51:59]
      system image file is:    bootflash:/nexus-1010-mz.4.2.1.SP1.3.bin
      system compile time:     7/8/2011 18:00:00 [07/09/2011 05:16:25]
    Hardware
      cisco Nexus 1010 (Virtual Services Appliance) 2 slot Chassis ("Nexus 1010 (Virtual Services Appliance)")
       with 14304256 kB of memory.
      Processor Board ID T023D701401
      Device name: NTM-DC-VSA-01
      bootflash:    3897832 kB
      Disk Storage capacity for VM virtual disks: 346264 MB
      Number of physical 1Gbps ethernet ports: 6

    Thanks a lot Mathew! Would be nice if someone could update the install and upgrade guides so it's clear 1010 and 1010-X are supported as well as the 1110-S and 1110-X.

  • Installing DCNM-SAN as a VSB in Nexus 1010

    Hi everyone,
    I'm trying to install DCNM-SAN as a VSB in Nexus 1010, as I've read on the release notes that since 5.2.x release the distribution is done via a single image and there's an image available right now for 5.2(2)...
    But, although I've tried numerous times (together with reading a lot through the two available documents - Installation and licensing guide and Fundamentals), every time I create a new vsb with these images, it becomes a DCNM-LAN install.
    I have yet to have any prior experience with DCNM, so I might be missing something.
    Any ideas? What am I missing? Am I trying to do something that is not supported? Or, am I just missing a critical point there?
    NOTE: This is currently a lab topology, but I have a customer that's very keen on using DCNM-SAN with their MDS switches. And I feel that having this on a the 1010 as a vsb is the best way to do it, if it can be done, with regards to having network staff not deal with servers etc.
    Thanks,
    Emre

    Andrew,
    We are a little frustrated with the VSB version of DCNM-SAN, it does not appear possible to manage fabric without advanced licensing for the switches, in the licensing guides for DCNM it lists essentials capability that should include port, switch, and fabric-level configuration. On the windows version we can manage the fabric unlicensed as long as we do it from the server direcly or in previous versions if we are running stand alone. These options do not appear to exist for the VSB version. Is there any plan to include any essentials capability in the VSB/OVF versions of the DCNM-SAN. If this is not planned, the documentation should be changed to state that essentials functions are only available in the Windows version.

  • I played a rented movie in my newly bought ATV, but when i wanted to watch a TV Series i got the "Authorization is Required" !! although i have successfully played a rented movie at first !! and when checking into iTunes i couldnt find the ATV??

    I played a rented movie in my newly bought ATV, but when i wanted to watch a TV Series i got the "Authorization is Required" !! although i have successfully played a rented movie at first !! and when checking into iTunes i couldnt find the ATV??

    The ATV2 or ATV3 (small black boxes) don't show up as devices in iTunes. If iTunes and the ATV's have Home sharing turned on for the same account - and are on the same network, the ATV should show up as an AirPlay target device in iTunes.
    The rented movie - was this rented on the ATV or in iTunes?
    The TV series - where are you trying to play this from? Is it in iTunes or via the 'TV Shows' menu in ATV... i.e streaming from iCloud?

  • Nexus 1010 HA Active with warm standby

    I have deployed two 1010 appliances, the upstream switches are two 6509 wihtout VSS.
    I cannot get the HA up.
    Output of show module is:
    Mod  Ports  Module-Type                       Model               Status
    1    0      Nexus 1010 (Virtual Services App  Nexus1010           active *
    2    0      Virtual Supervisor Module                             powered-up
    Mod  Sw                Hw
    1    4.2(1)SP1(3)      0.0
    Mod  MAC-Address(es)                         Serial-Num
    1    00-19-07-6c-5a-a8 to 00-19-07-6c-62-a8  NA
    Mod  Server-IP        Server-UUID                           Server-Name
    1    10.146.102.10    NA                                    NA
    Output of show system redundancy status is :
    Redundancy role
          administrative:   primary
             operational:   primary
    Redundancy mode
          administrative:   HA
             operational:   None
    This supervisor (sup-1)
        Redundancy state:   Active
        Supervisor state:   Active
          Internal state:   Active with warm standby
    Other supervisor (sup-2)
        Redundancy state:   Standby
    Error in getting supervisor and internal state of other supervisor.
    and the output of show system internal redundancy info is:
    My CP:
      slot: 0
      domain: 25
      role:   primary
      status: RDN_ST_AC
      state:  RDN_DRV_ST_AC_SB
      intr:   enabled
      power_off_reqs: 0
      reset_reqs:     9
    Other CP:
      slot: 1
      status: RDN_ST_SB
      active: true
      ver_rcvd: true
      degraded_mode: true
    Redun Device 0:
      name: ha0
      pdev: f37e8640
      alarm: true
      mac: ff:ff:ff:ff:ff:ff
      tx_set_ver_req_pkts:   319
      tx_set_ver_rsp_pkts:   0
      tx_heartbeat_req_pkts: 61193
      tx_heartbeat_rsp_pkts: 0
      rx_set_ver_req_pkts:   0
      rx_set_ver_rsp_pkts:   0
      rx_heartbeat_req_pkts: 0
      rx_heartbeat_rsp_pkts: 0
      rx_drops_wrong_domain: 0
      rx_drops_wrong_slot:   0
      rx_drops_short_pkt:    0
      rx_drops_queue_full:   0
      rx_drops_inactive_cp:  0
      rx_drops_bad_src:      0
      rx_drops_not_ready:    0
      rx_drops_wrong_ver:    0
      rx_unknown_pkts:       0
    Redun Device 1:
      name: ha1
      pdev: f37e8240
      alarm: false
      mac: 00:02:3d:70:19:81
      tx_set_ver_req_pkts:   314
      tx_set_ver_rsp_pkts:   0
      tx_heartbeat_req_pkts: 61193
      tx_heartbeat_rsp_pkts: 0
      rx_set_ver_req_pkts:   0
      rx_set_ver_rsp_pkts:   5
      rx_heartbeat_req_pkts: 0
      rx_heartbeat_rsp_pkts: 61165
      rx_drops_wrong_domain: 0
      rx_drops_wrong_slot:   0
      rx_drops_short_pkt:    0
      rx_drops_queue_full:   0
      rx_drops_inactive_cp:  0
      rx_drops_bad_src:      0
      rx_drops_not_ready:    0
      rx_drops_wrong_ver:    0
      rx_unknown_pkts:       0
    Can anyone please help in resolving this issue.
    Regards,
    Sabih

    Hi Sabih,
    For a Nexus 1010 pair to form HA redundancy, the communicate with each other via the Control VLAN. You would have specified this during your installation.
    Can you verify that they are both utilizing the same Control VLAN.
    n1010# show svs domain
    Furthermore, ensure that this vlan is defined and forwarding, on the relevant ports, on the upstream 6509s.
    Thanks,
    Michael

  • Nexus 1010 - Issue copying s/w onto device using SCP.

    Hi
    I'm trying to copy the new version of s/w ( nexus-1000v.4.2.1.SV1.4.iso) onto a Nexus 1010 switch using the command:
    copy scp: bootflash:repository
    The software starts to copy but unfortunately only gets to around 10% complete before failing. It's almost like it's getting stuck for some reason?
    The file is quite large (163Mb), however, there is plenty of space on the disk (see below) so I cannot understand while this is happening.
    switch# dir bootflash:repository
          16384     Nov 05 17:48:52 2010  lost+found/
      156403712     Nov 05 17:52:02 2010  nam-4-2-1.iso
      133965824     Nov 05 17:53:02 2010  nexus-1000v.4.0.4.SV1.3b.iso
    Usage for bootflash://sup-local
      305950720 bytes used
    3685429248 bytes free
    3991379968 bytes total
    Does anyone have any suggestions as to why this is happening? Below is the exact output from the box:
    switch# copy scp: bootflash:repository
    Enter source filename: nexus-1000v.4.2.1.SV1.4.iso
    Enter vrf (If no input, current vrf 'default' is considered):
    Enter hostname for the scp server: 10.214.30.56
    Enter username: 00000001
    [email protected]'s
    password:
    nexus-1000v.4.2.1.SV1.4.iso                     9%   15MB   0.0KB/s - stalled -Read from remote host 10.214.30.56: Connection reset by peer
    lost connection

    Hi guys,
    Any ideas on this?

  • No export command in Nexus 1010

    Hi all,
    We want to do a backup of a virtual-service-blade in a Nexus 1010. The document we are following is:
    http://www.cisco.com/en/US/docs/switches/datacenter/nexus1000/sw/4_2_1_s_p_1_3/software/configuration/guide/n1010_vsvcs_cfg_7backup.html
    What we are supposed to do fron this document is to create a file named export-import, to shutdown the primary o secondary virtual service blades, and after it, to execute the command "export primary" o "export secondary", depending on which vsb we want to export.
    ========= DETAILED STEP IN THE DOCUMENT ================
    n1010-1(config-vsb-config)# export  secondary
    Note: export started..
    Note: please be patient..
    Note: please be patient..
    Note: please be patient..
    Note: export  completed...n1010-1(config-vsb-config)#
    ====================================================
    The problem is that this "export" command is not available in our nexus 1010.
    =========== NEXUS 1010 ===============================
    N1010-MGMT(config-vsb-config)# export secondary
                                     ^
    % Invalid command at '^' marker.
    N1010-MGMT(config-vsb-config)#
    N1010-MGMT(config-vsb-config)#
    N1010-MGMT(config-vsb-config)# ?
      description                 Virtual service blade description
      disksize                    Configure disk size
      enable                      Deploy/remove the virtual service blade
      interface                   Configure virtual service blade interface vlan
      no                          Negate a command or set its defaults
      numcpu                      Configure numcpu
      ramsize                     Configure ram size
      shutdown                    Start/stop the virtual service blade
      virtual-service-blade-type  Select the virtual service blade type
      end                         Go to exec mode
      exit                        Exit from command interpreter
      pop                         Pop mode from stack or restore from name
      push                        Push current mode to stack or save it under name
      where                       Shows the cli context you are in
    =====================================================
    The version of the nexus is the same than the document's one.
    Document: 4.2(1)SP1(3) ==> Nexus 1010: version 4.2(1)SP1(2)
    Software
      loader:    version unavailable [last: loader version not available]
      kickstart: version 4.2(1)SP1(2)
      system:    version 4.2(1)SP1(2)
      kickstart image file is: bootflash:/nexus-1010-kickstart-mz.4.2.1.SP1.2.bin
      kickstart compile time:  1/27/2011 14:00:00 [01/28/2011 01:14:35]
      system image file is:    bootflash:/nexus-1010-mz.4.2.1.SP1.2.bin
      system compile time:     1/27/2011 14:00:00 [01/28/2011 04:13:25]
    Hardware
      cisco Nexus 1010 Chassis ("Cisco Nexus1010 Chassis")
       with 14665728 kB of memory.
      Processor Board ID T023D700201
    We don't know which can be the problem, wheter it can be a bug in the software, or we are doing something wrong.
    Thank you

    The export command was a new feature added in the 4.2(1)SP1(3) version of code. Your 1010 is one rev lower.
    You'll need to upgrade the code on the 1010 to the latest code to get the export command.
    The upgrade is pretty straight forward. Just download the code and follow the upgrade guide.
    louis

  • Nexus 1010 Deployment Process

    Hi,
    Initially we deployed VSM on a VM and that was working fine. Now the customer has bought a 1010 appliance and wants us to configure VSMs on the 1010 appliance.
    I just want to confirm that the steps that I can up with after going through cisco documents is the right approach.
    1) Boot up 1010 appliance complete the intial configuration i.e.
         a) setup admin password and uplink type
         b) set control vlan id, domain id, mgmt id
         c) set the mgmt0 address
         d) configure the rest of the settings
    2) Boot up 1010 secondary appliance and set the domain id and control vlan id and mgmt id.
    After this I will be able to see the active and primary chassis in sh module.
    after the initail configuration can the chasis be used as a VSM and can I directly configure port-profiles and deploy vem ?
    Or do i need to install VSM as a VSB and then configure port-profiles and deploy vem?
    And when I deploy VSM as a Virtual services blade i need to share the management network, what else should be taken care of ?
    Regards,
    Sabih

    Hello Sabih,
    The migration guides has exact steps for moving from a VSM on ESX environment to N1010.  This process allows you to migrate the VSM w/o the need to reinstall / reconfigure on the N1010s.
    http://www.cisco.com/en/US/docs/switches/datacenter/nexus1000/sw/4_2_1_s_p_1_3/software/configuration/guide/n1010_vsvcs_cfg_6migrate.html
    The management, control, packet vlans need to be shared between the N1010/VSB & existing VSM for a successful migration.
    Please let me know if you have any questions.
    Matthew

  • Nexus 1010 + 1000v control vlan issue

                       Hi,
    I have Nexus 1000v installed on nexus 1010. The nexus 1010 is in cluster and working fine. I have made network uplink option 3.
    My VSM is configured to be on L3 mode. Hence I set control and packet vlan to 1 (on vsm). while creating the VSB too I have choosen control and packet vlan to be 1 (keeping in mind my mode will be L3).
    Now The vsm is not coming up in HA. The redandancy log says degraded mode is true.
    Is it because, the control packet coming from VSM after reaching the N1010, the packets are getting tagged with vlan 1. Since I have not set any native vlan on 1010, might be control vlan 1 is also tagged one. Is it this the case ?
    help needed on this issue.
    regards
    Prasad K

    Control vlan is a totally seperate VLAN then your System Console. The VLAN just needs to be available to the ESX host through the upstream physical switch and then make sure the VLAN is passed on the uplink port-profile that you assign the ESX host to.
    We only need an interface on the ESX host if you decide to use L3 control. In that instance you would create or use an existing VMK interface on the ESX host.

  • Nexus 1010 HA Error

                  Hi,
    While I bring Up Secondary Nexus 1010 I am getting this error on primary
    Error in getting supervisor and internal state of other supervisor.
    sh redundancy status
    Redundancy role
          administrative:   primary
             operational:   primary
    Redundancy mode
          administrative:   HA
             operational:   None
    This supervisor (sup-1)
        Redundancy state:   Active
        Supervisor state:   Active
          Internal state:   Active with warm standby
    Other supervisor (sup-2)
        Redundancy state:   Standby
    Error in getting supervisor and internal state of other supervisor.
    On the redundant (standy ) unit I am getting this message
    %SYSLOG-2-SYSTEM_MSG: Did not receive supstate notification in 180 seconds. Still waiting
    What could be possible reason ? can this be a firmware mismatch ? Both are having same configuration for management control and packet vlan. Both are on same L2 network. If I disconnect the standby unit management cable, it will boot. But if management cable is connected, it will be stuck in the above phase.
    regards
    Prasad K

    Prasad,
    This means that there is some sort of a communication issue between the two Nexus 1010 switches in the control VLAN. You should probably check the upstream configuration on the ports that connect to the 1010 links carrying the control traffic and also the links involved in the control path.
    Thanks,
    Shankar

  • I got my newly bought (within 30 days) ipad mini cracked, and the screen was broken, where can I find a place(montreal) to replace it, and how much will it cost?

    I got my newly bought (within 30 days) ipad mini cracked, and the screen was broken, where can I find a place(montreal) to replace it, and how much will it cost? Can i get a free replacement in apple store since within 30 days?

    huilihuili wrote:
    Can i get a free replacement in apple store since within 30 days?
    No. Damage caused by the user is not covered by warranty. A replacement iPad mini is $219 for the 1st generation, or $249 for the iPad mini with Retina display.

Maybe you are looking for