Nexus 1000v: Control VLAN must be same VLAN as ESX hosts?

Hello,
I'm trying to install nexus 1000v and came across the below prerequisite.
The below release notes for Nexus 1000v states
VMware and Host Prerequisites
The VSM VM control interface must be on the same Layer 2 VLAN as the ESX 4.0 host that it manages. If you configure Layer 3, then you do not have this restriction. In each case however, the two VSMs must run in the same IP subnet.
What I'm trying to do is to create 2 VLANs - one for management and the other for control & Data (as per latest deployment guide, we can put control & data in the same vlan).
However, I wanted to have all ESX host management same VLAN as the VSM management as well as the vCenter Management. Essentially, creating a management network.
However, from the above "VMWare and Host Prerequisites", does this means I cannot do this?
I need to have the ESX host management same VLAN as the control VLAN?
This means that my ESX host will reside in a different VLAN than my management subnet?
Thanks...

Control vlan is a totally seperate VLAN then your System Console. The VLAN just needs to be available to the ESX host through the upstream physical switch and then make sure the VLAN is passed on the uplink port-profile that you assign the ESX host to.
We only need an interface on the ESX host if you decide to use L3 control. In that instance you would create or use an existing VMK interface on the ESX host.

Similar Messages

  • WLC 7.4.110.0 where native vlan and SSID vlan is the same vlan

    Hi
    We have app. 1500 accespoints in app. 500 locations. WLCs are WiSM2s running 7.4.110.0. The AP are 1131LAPs.In a FlexConnect configuration we use vlan 410 as native vlan and the ssid (LAN) also in vlan 410. This works fine, never had any problems with this.
    Now we have started use 1602 APs and the client connection on ssid LAN becomes unstable.
    If we configure an different ssid, using vlan 420 and native vlan as 410, everything works fine.
    I can't find any recommandations regarding the use of native vlan/ssid vlan
    Is there anyone experiencing similar problems? Is this a problem with my configuration or is it a bug wittin 1602 accespoints?
    Regards,
    Lars Christian

    It is the recomended design to put FlexConnect AP mgt into native vlan & user traffic to a tagged vlan.
    From the QoS perspective if you want to enforce WLC QoS profile values, you have to tag SSID traffic to a vlan (other than native vlan) & trust CoS on the switch port connected to FlexConnect AP (usually configured as trunk port)
    HTH
    Rasika
    **** Pls rate all useful responses ****

  • Nexus 1000V - Control - Packet Interfaces - vSwitch

    Hello,
    Is it possible to leave Control interface and Packet interface of my VSM on a standard vmware vswitch ?
    Same question as above for the management interface ?
    Thanks.

    Sure it is possible to leave the VSM on a vswitch if you can spare the extra physical uplinks for the vswitch.
    The VSM can reside on a server running a virtual Ethernet module (VEM), or a VMware vSwitch or DVS. If the host is running a VEM, that VEM can be managed by the VSM on the same host or a VSM on another host.
    http://www.cisco.com/en/US/docs/switches/datacenter/nexus1000/sw/4_2_1_s_v_1_4_b/install/software/guide/n1000v_install_software.html

  • How to change Nexus 1010 and Nexus 1000v IP address

    Hi Experts,
    We had run two VSM and one NAM in the Nexus 1010. The Nexus 1010 version is 4.2.1.SP1.4. And the Nexus 1000v version is 4.0.4.SV1.3c. Now we must to change management IP address to the other one. Where can I find the SOP or config sample? And have anything I must to remind?

    If it's only the mgmt0 IP address that you are changing, then you can just enter the new address under the mgmt0 interface. It will automatically sync with the VC.
    I guess you are trying to change the IP address of the VC plus the management VLAN as well. One way of doing this is:
    - From the Nexus 1000v, disconnect the connection to the VC (svs connection -> no connect)
    - Change the VC IP address and connect to it (svs connection -> remote ip address)
    - Change the Nexus 1000v mgmt0 address
    - Change the mgmt VLAN on the N1010
    - Change the mgmt address of the N1010
    - Reconnect the Nexus 1000v back to the VC (svs connection -> connect)
    Correspondingly, change the VLAN configuration on the upstream switch plus the connection to the VC as well.
    Thanks,
    Shankar

  • Nexus 1000v VSM can't comunicate with the VEM

    This is the configuration I have on my vsm
    !Command: show running-config
    !Time: Thu Dec 20 02:15:30 2012
    version 4.2(1)SV2(1.1)
    svs switch edition essential
    no feature telnet
    banner motd #Nexus 1000v Switch#
    ssh key rsa 2048
    ip domain-lookup
    ip host Nexus-1000v 172.16.0.69
    hostname Nexus-1000v
    errdisable recovery cause failed-port-state
    vem 3
      host vmware id 78201fe5-cc43-e211-0000-00000000000c
    vem 4
      host vmware id e51f2078-43cc-11e2-0000-000000000009
    priv 0xa2cb98ffa3f2bc53380d54d63b6752db localizedkey
    vrf context management
      ip route 0.0.0.0/0 172.16.0.1
    vlan 1-2
    port-channel load-balance ethernet source-mac
    port-profile default max-ports 32
    port-profile type ethernet Unused_Or_Quarantine_Uplink
      vmware port-group
      shutdown
      description Port-group created for Nexus1000V internal usage. Do not use.
      state enabled
    port-profile type vethernet Unused_Or_Quarantine_Veth
      vmware port-group
      shutdown
      description Port-group created for Nexus1000V internal usage. Do not use.
      state enabled
    port-profile type ethernet vmware-uplinks
      vmware port-group
      switchport mode trunk
      switchport trunk allowed vlan 1-3967,4048-4093
      channel-group auto mode on
      no shutdown
      system vlan 2
      state enabled
    port-profile type vethernet Management
      vmware port-group
      switchport mode access
      switchport access vlan 2
      no shutdown
      state enabled
    port-profile type vethernet vMotion
      vmware port-group
      switchport mode access
      switchport access vlan 2
      no shutdown
      state enabled
    port-profile type vethernet ServidoresGestion
      vmware port-group
      switchport mode access
      switchport access vlan 2
      no shutdown
      state enabled
    port-profile type vethernet L3-VSM
      capability l3control
      vmware port-group
      switchport mode access
      switchport access vlan 2
      no shutdown
      system vlan 2
      state enabled
    port-profile type vethernet VSG-Data
      vmware port-group
      switchport mode access
      switchport access vlan 2
      no shutdown
      state enabled
    port-profile type vethernet VSG-HA
      vmware port-group
      switchport mode access
      switchport access vlan 2
      no shutdown
      state enabled
    vdc Nexus-1000v id 1
      limit-resource vlan minimum 16 maximum 2049
      limit-resource monitor-session minimum 0 maximum 2
      limit-resource vrf minimum 16 maximum 8192
      limit-resource port-channel minimum 0 maximum 768
      limit-resource u4route-mem minimum 1 maximum 1
      limit-resource u6route-mem minimum 1 maximum 1
    interface mgmt0
      ip address 172.16.0.69/25
    interface control0
    line console
    boot kickstart bootflash:/nexus-1000v-kickstart.4.2.1.SV2.1.1.bin sup-1
    boot system bootflash:/nexus-1000v.4.2.1.SV2.1.1.bin sup-1
    boot kickstart bootflash:/nexus-1000v-kickstart.4.2.1.SV2.1.1.bin sup-2
    boot system bootflash:/nexus-1000v.4.2.1.SV2.1.1.bin sup-2
    svs-domain
      domain id 1
      control vlan 1
      packet vlan 1
      svs mode L3 interface mgmt0
    svs connection vcenter
      protocol vmware-vim
      remote ip address 172.16.0.66 port 80
      vmware dvs uuid "ae 31 14 50 cf b2 e7 3a-5c 48 65 0f 01 9b b5 b1" datacenter-n
    ame DTIC Datacenter
      admin user n1kUser
      max-ports 8192
      connect
    vservice global type vsg
      tcp state-checks invalid-ack
      tcp state-checks seq-past-window
      no tcp state-checks window-variation
      no bypass asa-traffic
    vnm-policy-agent
      registration-ip 172.16.0.70
      shared-secret **********
      policy-agent-image bootflash:/vnmc-vsmpa.2.0.0.38.bin
      log-level
    for some reason my vsm can't the the vem. I could before, but then my server crashed without doing a copy run start and when it booted up all my config but the uplinks was lost.
    When I tried to configure the connection again it wasn't working.
    I'm also attaching a screen capture of the vds
    and a capture of the regular switch.
    I will appreciate very much any help you could give me and will provide any configuration details that you might need.
    Thank you so much.

    Carlos,
       Looking at vds.jpg, you do not have any VEM vmkernel interface attached to port-profile L3-VSM. So fix VSM-VEM communication problem, you either migrate your VEM management vmkernel interface to L3-VSM port-profile of the vds, or create new VMkernel port on your VEM/host and attach it to L3-VSM port-profile.

  • Cisco Nexus 1000V InterCloud

    Need download link for Cisco Nexus 1000V InterCloud

    We had a simliar issue with 5.2(1)SV3(1.3) and found this in the release notes:
    ERSPAN
    If the ERSPAN source and destination are in different subnets, and if the ERSPAN source is an L3 control VM kernel NIC attached to a Cisco Nexus 1000V VEM, you must enable proxy-ARP on the upstream switch.
    If you do not enable proxy-ARP on the upstream switch (or router, if there is no default gateway), ERSPAN packets are not sent to the destination.
    http://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus1000/sw/5_x/release_notes/b_Cisco_N1KV_VMware_521SV313_ReleaseNotes.html#concept_652D9BADC4B04C0997E7F6C29A2C8B1F
    After enabling 'ip proxy-arp' on the upstream SVI it started working properly.

  • RSPAN VLAN on a Data VLAN

    Hi all.
    We have offices for rent and each has a dedicated VLAN for our office staff and separate VLANs for each client that will be renting on our office.
    Each office has a small topology, usually a star, and one of the edge switches has a mirrored port and the source port will be the core's uplink to the FW. So is it alright to put the RSPAN VLAN on the same VLAN as the office staff VLAN? Or should I have a dedicated VLAN for RSPAN?
    The reason I'm asking is because, if I propose to create a separate VLAN, then we'll need to create it on the switches and firewalls on all offices, additional firewall rules. etc..
    Please advise. Thanks!

    Hi
    It would be a very bad idea to use a normal VLAN as an RSPAN VLAN. You should create a new VLAN dedicated for this purpose.
    Please see this list of differences in the behavior of the VLAN types:
    http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst3560/software/release/12-2_52_se/configuration/guide/3560scg/swspan.html#wp1200730
    Regards
    Aaron

  • Nexus 7010 and ESX Host

    Hi,
    We are currently seeing issues on a ESX Host using 10G Fibre dual connectivity to a pair of Nexus 7010's using vPC for the port channel to this ESX host which was working fine , up to this weekend. No changes had been made on the Nexus or ESX host.
    We have changed the hardware path for the believed fault on a vmnic which when part of the virtual switch cause VM's on the Host to stop pinging, although we still see a CDP neighborship with the ESX from the Nexus, but changing fibre and Nexus ports has not worked.
    As part of the testing , the vmware guy was removing this 'faulty' vmnic from the Virtual switch , which is part of an ether channel bundle his end. My first question is, how does the Nexus detect a link leaving the bundle for the ESX host , when the actual physical link is still up , and all they have done is software removed it from on the ESX, as the Nexus will still attempt to push traffic across both bundled links. I know there is the Cisco 1000V software , which can be used at an extra price, but is this the only option.
    Any help will be gladly welcome.

    Hi
    How the switch detects a link 'moving out' of the Etherchannel would depend on how you have configured it...
    If you have used 'channel-group x mode on' under the physical ports in the channel, then it will not detect the change, and you will get problems. The solution is to ensure the config of the channel on both ends (server/switch) is consistent in this case. An inconsistent config will cause you connectivity issues.
    If the switch automatically negotiates the Etherchannel (i.e. you are using LACP, and the server supports LACP) then it should detect the change.
    Regards
    Aaron
    Please rate helpful posts...

  • Nexus 1010 + 1000v control vlan issue

                       Hi,
    I have Nexus 1000v installed on nexus 1010. The nexus 1010 is in cluster and working fine. I have made network uplink option 3.
    My VSM is configured to be on L3 mode. Hence I set control and packet vlan to 1 (on vsm). while creating the VSB too I have choosen control and packet vlan to be 1 (keeping in mind my mode will be L3).
    Now The vsm is not coming up in HA. The redandancy log says degraded mode is true.
    Is it because, the control packet coming from VSM after reaching the N1010, the packets are getting tagged with vlan 1. Since I have not set any native vlan on 1010, might be control vlan 1 is also tagged one. Is it this the case ?
    help needed on this issue.
    regards
    Prasad K

    Control vlan is a totally seperate VLAN then your System Console. The VLAN just needs to be available to the ESX host through the upstream physical switch and then make sure the VLAN is passed on the uplink port-profile that you assign the ESX host to.
    We only need an interface on the ESX host if you decide to use L3 control. In that instance you would create or use an existing VMK interface on the ESX host.

  • Nexus 1000V private-vlan issue

    Hello
    /* Style Definitions */
    table.MsoNormalTable
    {mso-style-name:Standardowy;
    mso-tstyle-rowband-size:0;
    mso-tstyle-colband-size:0;
    mso-style-noshow:yes;
    mso-style-parent:"";
    mso-padding-alt:0cm 5.4pt 0cm 5.4pt;
    mso-para-margin:0cm;
    mso-para-margin-bottom:.0001pt;
    mso-pagination:widow-orphan;
    font-size:10.0pt;
    font-family:"Times New Roman";
    mso-ansi-language:#0400;
    mso-fareast-language:#0400;
    mso-bidi-language:#0400;}
    I need to transmit both the private-vlans (as promiscous trunk) and regular vlans on the trunk port between the Nexus 1000V and the physical switch. Do you know how to properly configure the uplink port to accomplish that ?
    Thank you in advance
    Lucas

    Control vlan is a totally seperate VLAN then your System Console. The VLAN just needs to be available to the ESX host through the upstream physical switch and then make sure the VLAN is passed on the uplink port-profile that you assign the ESX host to.
    We only need an interface on the ESX host if you decide to use L3 control. In that instance you would create or use an existing VMK interface on the ESX host.

  • Trunking Vlans in Nexus 1000V

    I am looking to design a solution for a customer and they run a very tight hosting environment with Nexus 1000V switches and want to setup private vlans as they are running out of vlans
    I need to find some info on if it is possible to trunk a private vlan between 2 nexus switches
    Or any info on private vlans on Nexus 1000V
    Thanks
    Roger

    Hello Roger,
    Yes, pVLANs can be trunked between switches.  A good discussion can be found here.  Have you considered VXLAN as an alternative to pVLANs?  VXLAN allows up to 16M segments definied though they differ slightly from pVLAN in that all VMs in a VXLAN segment can communicate.
    Matthew

  • Nexus 1000v Layer3 Control not coming up

    For info, I run 4.2(1)SV1(4) as a VM and not the appliance.
    I tried this morning to migrate a small environment to the Nexus L3 control instead of L2 for a certain requirement. We have two ESX in the with the Nexus 1000v running sucessfully for months on L2.
    I tried to follow the procedure that is in this document. I followed this script:
    Created a layer3 control0 interface with an IP in vlan951.
    So I had my VMWare guy move a VMKernel interface of each ESX host to this profile:
    port-profile type vethernet VLAN951
      vmware port-group VLAN951
      capability l3control
      switchport mode access
      switchport access vlan 951
      system vlan 951
      no shutdown
      state enabled
    Then modified the svs domain like such:
    svs-domain
    no control vlan
    no packet vlan
    svs mode 13 interface control0
    I made sure that I have layer-2 connectivity between the VSM host and the rest ESX hosts is OK, but I am not certain how you actually assign a layer 2 vlan to the control0 interface... Is it supposed to broadcast on all the VLANs? Or is it a correlation of the port-profile config and svs-domain that does that?
    In any case, my two VEM go down and do not come back up once I am in l3 mode. I had to revert back to L2.
    Any help would be appreciated.
    Regards,
    Simon T.

    Hi Simon,
    Since you are using ctrl0 as the layer 3 interface, you need to assign the IP address under the ctrl0 interface (interface ctrl0). This IP address should be able to communicate with the vmk interface's IP address.
    Regards,
    Shankar

  • Need to configure different SSIDs on same VLAN on 1142

    We're having a problem with interference in the B/G range due to the large number of access points owned by other companies in a fairly small area. The various laptops keep deauthenticating, which is causing problems with applications. I'd like to configure two SSIDs on the same VLAN but have them broadcasted on different frequencies. The AP complained about the configuration when I added the Company5.8 SSID below stating another SSID can't be added to a VLAN, but it shows in the configuration. Does any one have a suggestion as to what I can try? Thanks
    interface Dot11Radio0
     no ip address
     no ip route-cache
     encryption vlan 1 mode ciphers aes-ccm
     encryption vlan 3 mode ciphers aes-ccm
     ssid Moleculera Labs
     ssid Moleculera Labs-guest
     antenna gain 0
     mbssid
     channel least-congested 2412 2437 2462
     station-role root
    interface Dot11Radio0.1
     encapsulation dot1Q 1 native
     no ip route-cache
     bridge-group 1
     bridge-group 1 subscriber-loop-control
     bridge-group 1 block-unknown-source
     no bridge-group 1 source-learning
     no bridge-group 1 unicast-flooding
     bridge-group 1 spanning-disabled
    interface Dot11Radio0.3
     encapsulation dot1Q 3
     no ip route-cache
     bridge-group 3
     bridge-group 3 subscriber-loop-control
     bridge-group 3 block-unknown-source
     no bridge-group 3 source-learning
     no bridge-group 3 unicast-flooding
     bridge-group 3 spanning-disabled
    interface Dot11Radio1
     no ip address
     no ip route-cache
     encryption mode ciphers aes-ccm
     encryption vlan 1 mode ciphers aes-ccm
     encryption vlan 3 mode ciphers aes-ccm
     ssid Moleculera Labs
     ssid Moleculera Labs-guest
     antenna gain 0
     dfs band 3 block
     mbssid
     channel dfs
     station-role root
    interface Dot11Radio1.1
     encapsulation dot1Q 1 native
     no ip route-cache
     bridge-group 1
     bridge-group 1 subscriber-loop-control
     bridge-group 1 block-unknown-source
     no bridge-group 1 source-learning
     no bridge-group 1 unicast-flooding
     bridge-group 1 spanning-disabled
    interface Dot11Radio1.3
     encapsulation dot1Q 3
     no ip route-cache
     bridge-group 3
     bridge-group 3 subscriber-loop-control
     bridge-group 3 block-unknown-source
     no bridge-group 3 source-learning
     no bridge-group 3 unicast-flooding
     bridge-group 3 spanning-disabled

    Amjad, if I delete "encryption mode ciphers aes-ccm" what kind of encryption will the AP use?
    Mohanak, I'm using the same encryption settings with VLANs
    Here is the more complete configuration:
    version 12.4
    no service pad
    service timestamps debug datetime msec
    service timestamps log datetime msec
    service password-encryption
    hostname COMPANY-AP
    no logging console
    enable secret 5 *
    no aaa new-model
    no ip domain lookup
    ip domain name COMPANY.local
    dot11 syslog
    dot11 ssid COMPANY-2.4
       vlan 1
       authentication open
       authentication key-management wpa
       mbssid guest-mode
       wpa-psk ascii 7 *
    dot11 ssid COMPANY-5.8
       vlan 1
       authentication open
       authentication key-management wpa
       mbssid guest-mode
       wpa-psk ascii 7 *
    dot11 ssid COMPANY-guest
       vlan 3
       authentication open
       authentication key-management wpa
       guest-mode
       mbssid guest-mode
       wpa-psk ascii 7 *
    bridge irb
    interface Dot11Radio0
     no ip address
     no ip route-cache
     encryption vlan 1 mode ciphers aes-ccm
     encryption vlan 3 mode ciphers aes-ccm
     ssid COMPANY-2.4
     ssid COMPANY-guest
     antenna gain 0
     mbssid
     station-role root
    interface Dot11Radio0.1
     encapsulation dot1Q 1 native
     no ip route-cache
     bridge-group 1
     bridge-group 1 subscriber-loop-control
     bridge-group 1 block-unknown-source
     no bridge-group 1 source-learning
     no bridge-group 1 unicast-flooding
     bridge-group 1 spanning-disabled
    interface Dot11Radio0.3
     encapsulation dot1Q 3
     no ip route-cache
     bridge-group 3
     bridge-group 3 subscriber-loop-control
     bridge-group 3 block-unknown-source
     no bridge-group 3 source-learning
     no bridge-group 3 unicast-flooding
     bridge-group 3 spanning-disabled
    interface Dot11Radio1
     no ip address
     no ip route-cache
     encryption mode ciphers aes-ccm
     encryption vlan 1 mode ciphers aes-ccm
     encryption vlan 3 mode ciphers aes-ccm
     ssid COMPANY-2.4  (Want this to be COMPANY-5.8)
     ssid COMPANY-guest
     antenna gain 0
     dfs band 3 block
     mbssid
     channel dfs
     station-role root
    interface Dot11Radio1.1
     encapsulation dot1Q 1 native
     no ip route-cache
     bridge-group 1
     bridge-group 1 subscriber-loop-control
     bridge-group 1 block-unknown-source
     no bridge-group 1 source-learning
     no bridge-group 1 unicast-flooding
     bridge-group 1 spanning-disabled
    interface Dot11Radio1.3
     encapsulation dot1Q 3
     no ip route-cache
     bridge-group 3
     bridge-group 3 subscriber-loop-control
     bridge-group 3 block-unknown-source
     no bridge-group 3 source-learning
     no bridge-group 3 unicast-flooding
     bridge-group 3 spanning-disabled
    interface GigabitEthernet0
     no ip address
     no ip route-cache
     duplex auto
     speed auto
     no keepalive
    interface GigabitEthernet0.1
     encapsulation dot1Q 1 native
     no ip route-cache
     bridge-group 1
     no bridge-group 1 source-learning
     bridge-group 1 spanning-disabled
    interface GigabitEthernet0.3
     encapsulation dot1Q 3
     no ip route-cache
     bridge-group 3
     no bridge-group 3 source-learning
     bridge-group 3 spanning-disabled
    interface BVI1
     ip address 192.168.67.3 255.255.255.0
     no ip route-cache
    ip default-gateway 192.168.67.1
    ip http server
    ip http secure-server
    ip http help-path http://www.cisco.com/warp/public/779/smbiz/prodconfig/help/eag
    bridge 1 route ip
    line con 0
    line vty 0 4
     exec-timeout 30 0
     password 7 *
     login local
    end
    COMPANY-AP#

  • Policy based routing to host in same vlan/subnet

    Hello i have nexus 7k that i have a policy based routing setup as follows for 2 vlans, 802 and 803, to set default route out to a host in vlan 802. i have applied my policy to the vlans and everything works fine for a host in vlan 803, it routes over and out properly. However when im in vlan 802 my host traffic never gets to 172.21.1.237 when pointed at the gateway 172.21.1.1. I can see the pbr statistics incrementing indicating that i am initially hitting the policy but im not sure where my traffic goes after that. I can talk to .237 direct in the vlan but i would like this to work through pbr to utilize all of my other routes and default gateway.
    vlans 802
    172.21.1.1/24
    ip policy route-map West
    vlan 803
    172.21.17.1/24
    ip policy route-map West
    route-map West permit 10
      match vlan 802-803
      set ip default next-hop 172.21.1.237
    Im thinking there is some kind of hairpinning problem or maybe im creating some kind of blackhole.
    any help is appreciated.
    thanks, scott

    Scott
    If the destination IP is in the same subnet as source IP then it won't be routed it will be L2 switched so it would never use the default gateway ie.
    src IP 172.21.1.10 255.255.255.0
    dst IP 172.21.1.237 255.255.255.0
    src compares it's own IP with it's subnet mask and sees it is on the 172.21.1.x network. src then compares the destination IP with it's own subnet mask and sees it is also on the 172.21.1.x network so it simply arps out for that address and when it gets the mac address it sends it direct to the destination. It would only use the default gateway if the destination IP was on a different network.
    So i don't see how you will be able to do this and i'm not sure why you are seeing hits in your PBR acl for the host in the 172.21.1.x network.
    Edit - what exactly do you mean when you say -
    However when im in vlan 802 my host traffic never gets to 172.21.1.237 when pointed at the gateway 172.21.1.1.
    How are you doing this ie. pointing it to the default gateway because as i say it should always be able to communicate with 172.21.1.237 as it is in the same subnet.
    Jon

  • Nexus 1000V - port-profile for VSM and VEM on same host

    Hello,
    I'm trying to run the VSM and VEM on the same host. At first I connected the VSM to the vSwitch. This works fine. Then I tried to move the VSM behind its own VEM.
    I have 3 different VLANs for management, control and packet traffic. Is it possible to connect the three VSM interfaces (management, control and packet) to only one port-profile, in which these three different VLANs are configured in a trunk? Or do I have to configure for each interface a separate port-profile, if I am using three different VLANs?
    Thanks
    Tobias

    Hello,
        The VSM does not emit VLAN-tagged frames. Therefore, its ports need to be configured in access mode. If your Control and Packet VLANs are the same, you could use the same port profile for both.
    Please make sure that the access VLAN is a system VLAN for all three ports.
    On a related note, if the VSM's storage is on NFS or iSCSI, the storage vmknic needs a system port profile as well. More info at:
    http://www.cisco.com/en/US/docs/switches/datacenter/nexus1000/sw/4_0_4_s_v_1_3/getting_started/configuration/guide/n1000v_gsg_5vsm_behind_vem.html

Maybe you are looking for

  • F4IF_INT_TABLE_VALUE_REQUEST -Restrictions dialog box

    Hi, I am using the function module F4IF_INT_TABLE_VALUE_REQUEST in screens, to implement a search help in my program , but instead of directly displaying the hit list , i want the restrictions screen to be displayed first with some default values, an

  • Problem with NT4 and 120 Gb. raid partition

    Hi, My motherboard is a 694D Pro AR (MS-6321, rev 1) This has onboard Firewire (IEEE 1394) and onboard RAID (via the Promise Fastrak100 RAID controller built on the board). The Operating system is in an IBM 45 GB. disk. attach to IDE 100 controller 1

  • Firefox 8.1 won't start.

    Every time a message pops up - "Your computer must be restarted to complete a previous upgrade of Firefox. Do you want to reboot?" I have rebooted my computer atleast 20 times but still the problem exists. I tried to uninstall firefox but the same me

  • Import from Designer crashes with IMAGE data type

    Hello, I'd like to report an issue with Data Modeler while importing from Oracle Designer. If you consider this a bug, please let me know if I need to do anything else to request a fix for it. I've used the import > Oracle Designer Model tool to impo

  • What does the extension aspx stand for?

    I have a file that was sent to me...and now I cannot open it! The extension is aspx, and I would like to know what that stands for? What program do I need to open this file in the correct format? Thanks Merry Christmas to you all!