Nexus 1000v UCS Manager M81KR

Hello everyone
I am confused about how works the integration between N1K and UCS Manager:
First question:
If two VMs on different ESXi and different VEM but in the same VLAN,would like to talk each other, the data flow between them is managed from the upstream switch( in this case UCS Fabric Inteconnect), isn'it?
I created a Ethernet uplink port-profile on N1K in switch port mode access(100), I created a vEthernet port-profile for the VM in switchport mode access(100) as well. In the Fabric Interconnect I created a vNIC profile for the physical NICs of ESXi(where there are the VMs). Also I created the vlan 100(the same in N1K)
Second question: With the configuration above, if I include in the vNIC profile the vlan 100 (not as native vlan) only, the two VMs can not ping each other. Instead if I include in the vNIC profile only the defaul vlan(I think it is the vlan 1) as native vlan evereything works fine. WHY????
Third question: How it works the tagging vlan on Fabric interconnectr and also in N1K.
I tried to read differnt documents, but I did not understand.
Thanks                 

Since you have defined switchport mode access vlan 100 on uplink port-profile of Nexus 1000v, it sends all ethernet frames untagged(without 802.1q tag).
When you include in the vNIC profile the vlan 100 (not as native vlan) ONLY like below screenshot, untagged frames are dropped because UCS expects all frames received on this port as tagged frames.
When you change vNIC template to include default vlan as native vlan ONLY like below screen shot, you basically bridge two vlans (vlan 100 and vlan 1) because UCS FI now puts all untagged frames in vlan 1. and sends untagged frames to other ESXi host and ESXi host again bridge vlan 1 to vlan 100 with switchport mode access vlan 100 on uplink port profile.

Similar Messages

  • Nexus 1000v UCS Manager and Cisco UCS M81KR

    Hello everyone
    I am confused about how works the integration between N1K and UCS Manager:
    First question:
    If two VMs on different ESXi and different VEM but in the same VLAN,would like to talk each other, the data flow between them is managed from the upstream switch( in this case UCS Fabric Inteconnect), isn'it?
    I created a Ethernet uplink port-profile on N1K in switch port mode access(100), I created a vEthernet port-profile for the VM in switchport mode access(100) as well. In the Fabric Interconnect I created a vNIC profile for the physical NICs of ESXi(where there are the VMs). Also I created the vlan 100(the same in N1K)
    Second question: With the configuration above, if I include in the vNIC profile the vlan 100 (not as native vlan) only, the two VMs can not ping each other. Instead if I include in the vNIC profile only the defaul vlan(I think it is the vlan 1) as native vlan evereything works fine. WHY????
    Third question: How it works the tagging vlan on Fabric interconnectr and also in N1K.
    I tried to read differnt documents, but I did not understand.
    Thanks                 

    This document may help...
    Best Practices in Deploying Cisco Nexus 1000V Series Switches on Cisco UCS B and C Series Cisco UCS Manager Servers
    http://www.cisco.com/en/US/prod/collateral/switches/ps9441/ps9902/white_paper_c11-558242.html
    If two VMs on different ESXi and different VEM but in the same  VLAN,would like to talk each other, the data flow between them is  managed from the upstream switch( in this case UCS Fabric Inteconnect),  isn'it?
    -Yes.  Each ESX host with the VEM will have one or more dedicated NICs for the VEMs to communicate with the upstream network.  These would be your 'type ethernet' port-profiles.  The ustream network would need to bridge the vlan between the two physicall nics.
    Second question: With the configuration above, if I include in the vNIC  profile the vlan 100 (not as native vlan) only, the two VMs can not ping  each other. Instead if I include in the vNIC profile only the defaul  vlan(I think it is the vlan 1) as native vlan evereything works fine.  WHY????
    -  The N1K port profiles are switchport access making them untagged.  This would be the native vlan in ucs.  If there is no native vlan in the UCS configuration, we do not have the upstream networking bridging the vlan.
    Third question: How it works the tagging vlan on Fabric interconnectr and also in N1K.
    -  All ports on the UCS are effectively trunks and you can define what vlans are allowed on the trunk as well as what vlan is passed natively or untagged.  In N1K, you will want to leave your vEthernet port profiles as 'switchport mode access'.  For your Ethernet profiles, you will want them to be 'switchport mode trunk'.  Use an used used vlan as the native vlan.  All production vlans will be passed from N1K to UCS as tagged vlans.
    Thank You,
    Dan Laden
    PDI Helpdesk
    http://www.cisco.com/go/pdihelpdesk

  • Nexus 1000v, VMWare ESX and Microsoft SC VMM

    Hi,
    Im curious if anybody has worked up any solutions managing network infrastructure for VMWare ESX hosts/vms with the Nexus 1000v and Microsoft's System Center Virtual Machine Manager.
    There currently exists support for the 1000v and ESX and SCVMM using the Cisco 1000v software for MS Hyper-V and SCVMM.   There is no suck support for VMWare ESX.
    Im curious as to what others with VMWare, Nexus 1000v or equivalent and SCVMM have done to work around this issue.
    Trying to get some ideas.
    Thanks

    Aaron,
    The steps you have above are correct, you will need steps 1 - 4 to get it working correctly.  Normally people will create a separate VLAN for their NLB interfaces/subnet, to prevent uncessisary flooding of mcast frames within the network.
    To answer your questions
    1) I've seen multiple customer run this configuration
    2) The steps you have are correct
    3) You can't enable/disable IGMP snooping on UCS.  It's enabled by default and not a configurable option.  There's no need to change anything within UCS in regards to MS NLB with the procedure above.  FYI - the ability to disable/enable IGMP snooping on UCS is slated for an upcoming release 2.1.
    This is the correct method untill the time we have the option of configuring static multicast mac entries on
    the Nexus 1000v.  If this is a feature you'd like, please open a TAC case and request for bug CSCtb93725 to be linked to your SR. 
    This will give more "push" to our develpment team to prioritize this request.
    Hopefully some other customers can share their experience.
    Regards,
    Robert

  • VN-Link Hardware require Nexus 1000v yes or not?

    I have a problem about VN-Link Hardware. When i create port profile on UCS Manager and Create Port Profile Client then vCenter will create Port Group too. But when i apply network in Virtual Machine by select Port Group in vCenter i can't see Virtual Maching Guest in VM tab on UCS Manager.
    Finally question VN-Link Hardware require Nexus 1000v install on ESX yes or not? in UCS Manager GUI document say need require DVS Switch.

    Thank you for reply. I have successfully turn on VN-Link hardware by follow this video --> http://tinyurl.com/23p896k
    and i have install Nexus 1000v VEM in ESX for turn on VN-Link hardware.
    I need test performance of CNA Card (palo) and report to my CEO.
    - How to test it?
    - What is tool for test?
    PS.Sorry for English language

  • Firewall between Nexus 1000V VSM and vCenter

    Hi,
    Customer has multiple security zones in environment, and VMware vCenter is located in a Management Security Zone. VSMs in security zones have dedicated management interface facing Management Security Zone with firewall in between. What ports do we need to open for the communication between VSMs and vCenter? The Nexus 1000V troubleshooting guide only mentioned TCP/80 and TCP/443. Are these outbound from VSM to vCenter? Is there any requirements from vCenter to VSM? What's the best practice for VSM management interface configuration in multiple security zones environment? Thanks.

    Avi -
    You need the connection between vCenter and the VSM anytime you want to add or make any changes to the existing port-profiles.  This is how the port-profiles become available to the virtual machines that reside on your ESX hosts.
    One problem when the vCenter is down is what you pointed out - configuration changes cannot be pushed
    The VEM/VSM relationship is independent of the VSM/vCenter connection.  There are separate VLANs or L3 interfaces that are used to pass information and heartbeats between the VSM and its VEMs.
    Jen

  • Nexus 1000v and vcenter domain admin account

    I changed out domain admin account on our domain in which vcenter services runs as and now its using a different services account. I am wondering if I need to update anything on the nexus 1000v switch side between the 1000v and venter

    Hi Dan,
    You are on the right track. However you can perform some of these function "online".
    First you want to ensure that you are running at a minimum, Nexus 1000v SV1(4a) as ESXi 5.0 only began support on this release. With SV1(4a), it provides support for both ESXi 5.0 and ESX/i 4.1.
    Then you can follow the procedure documented here:
    Upgrading from VMware Release 4.0/4.1 to VMware Release 5.0.0
    This document walks you through upgrading your ESX infrastructure to VMware Release 5.0.0 when Cisco Nexus 1000V is installed. It is required to be completed in the following order:
    1. Upgrade the VSMs and VEMs to Release 4.2(1)SV1(4a).
    2. Upgrade the VMware vCenter Server to VMware Release 5.0.0.
    3. Upgrade the VMware Update Manager to VMware Release 5.0.0.
    4. Upgrade your ESX hosts to VMware Release 5.0.0 with a custom ESXi image that includes the VEM bits.
    Upgrading the ESX/ESXi hosts consists of the following procedures:
    –Upgrading the vCenter Server
    –Upgrading the vCenter Update Manager
    –Augmenting the Customized ISO
    –Upgrading the ESXi Hosts
    There is also a 3 part video highlighting the procedure to perfrom the last two steps above (customized ISO and upgrading ESXi hosts)
    Video: Upgrading the VEM to VMware ESXi Release 5.0.0
    Hope that helps you with your upgrade.
    Thanks,
    Michael

  • Nexus 1000V. problem when working with the console VMWare

    I have a problem when working with the console VMWare.
    Sometimes it is impossible to connect any of the hypervisor to the guest OS managed by them.
    I get the message: "Unable connect to the MKS: Host address lookup for server <name of the hypervisor> failed: No such host is known."
    This message always appears in conjunction with the reconfiguration of virtual switch: "Reconfigure vNetwork Distributed Switch .... Initiated by Cisco_Nexus_1000V_ ....."
    Upon completion of the reconfiguration, Communication console, with guest OS is restored, or on its own or after a reboot srv-vc.
    In this time, I do not see any message in Nexus 1000v log.
    What is this?
    Thanks in advance.

    Smells of a DNS issue.  Are you sure your ESX hosts are reachable from your client via DNS hostname?  Try pinging them from a command prompt/terminal.  You may have DNS server issues.
    As a temp fix, edit your [windowspath]/system32/etc/drivers/hosts file and manually add the ESX host name and IP, then re-test.
    Regards,
    Robert

  • Weird syslog format messages with Nexus 1000v

    I'm  trying out the Nexus 1000v, and have the VEM configured to write logs to my  syslog server. The thing is, the messages are in a weird format that my  log management tools cannot parse. Here is an example:
    <189>: 2012 Oct 21 15:22:40 UTC: %VSHD-5-VSHD_SYSLOG_CONFIG_I: Configured from vty by admin on unknown_session
    I found the documentation rather  amusing, where it states "The syslog client functionality is RFC-5424  compliant" - doesn't look like they've even read the RFC! This is closer  to the format of the older (but more often found in the wild,  RFC3164... though not compliant with that either :/
    Anyway,  I guess the main issue here is that the hostname of the 1000v is not  being added to the logs (it is set in my config). Any ideas how I can  fix this?
    Thanks!

    Hi,
         Do you have vCenter install on Win2012 Server? The installation would not continue until you have vCenter installed.
    Hardik

  • [Nexus 1000v] VEM can't be add into VSM

    hi all,
    following my lab, i have some problems with Nexus 1000V when VEM can't be add into VSM.
    + on VSM has already installed on ESX 1 (standalone or ha) and you can see:
    Cisco_N1KV# show module
    Mod  Ports  Module-Type                       Model               Status
    1    0      Virtual Supervisor Module         Nexus1000V          active *
    Mod  Sw                Hw
    1    4.2(1)SV1(4a)     0.0
    Mod  MAC-Address(es)                         Serial-Num
    1    00-19-07-6c-5a-a8 to 00-19-07-6c-62-a8  NA
    Mod  Server-IP        Server-UUID                           Server-Name
    1    10.4.110.123     NA                                    NA
    + on ESX2 that 's installed VEM
    [root@esxhoadq ~]# vem status
    VEM modules are loaded
    Switch Name      Num Ports   Used Ports  Configured Ports  MTU     Uplinks
    vSwitch0         128         3           128               1500    vmnic0
    VEM Agent (vemdpa) is running
    [root@esxhoadq ~]#
    any advices for this,
    thanks so much

    Hi,
    i'm having similar issue: the VEM insatlled on the ESXi is not showing up on the VSM.
    please check from the following what can be wrong?
    This is the VEM status:
    ~ # vem status -v
    Package vssnet-esx5.5.0-00000-release
    Version 4.2.1.1.4.1.0-2.0.1
    Build 1
    Date Wed Jul 27 04:42:14 PDT 2011
    Number of PassThru NICs are 0
    VEM modules are loaded
    Switch Name     Num Ports   Used Ports Configured Ports MTU     Uplinks  
    vSwitch0         128         4           128               1500   vmnic0  
    DVS Name         Num Ports   Used Ports Configured Ports MTU     Uplinks  
    VSM11           256         40         256               1500   vmnic2,vmnic1
    Number of PassThru NICs are 0
    VEM Agent (vemdpa) is running
    ~ # vemcmd show port    
    LTL   VSM Port Admin Link State PC-LTL SGID Vem Port
       18               UP   UP   F/B*     0       vmnic1
       19             DOWN   UP   BLK       0       vmnic2
    * F/B: Port is BLOCKED on some of the vlans.
    Please run "vemcmd show port vlans" to see the details.
    ~ # vemcmd show trunk
    Trunk port 6 native_vlan 1 CBL 1
    vlan(1) cbl 1, vlan(111) cbl 1, vlan(112) cbl 1, vlan(3968) cbl 1, vlan(3969) cbl 1, vlan(3970) cbl 1, vlan(3971) cbl 1,
    Trunk port 16 native_vlan 1 CBL 1
    vlan(1) cbl 1, vlan(111) cbl 1, vlan(112) cbl 1, vlan(3968) cbl 1, vlan(3969) cbl 1, vlan(3970) cbl 1, vlan(3971) cbl 1,
    Trunk port 18 native_vlan 1 CBL 0
    vlan(111) cbl 1, vlan(112) cbl 1,
    ~ # vemcmd show port
    LTL   VSM Port Admin Link State PC-LTL SGID Vem Port
       18               UP   UP   F/B*     0       vmnic1
       19            DOWN   UP   BLK       0       vmnic2
    * F/B: Port is BLOCKED on some of the vlans.
    Please run "vemcmd show port vlans" to see the details.
    ~ # vemcmd show port vlans
                           Native VLAN   Allowed
    LTL   VSM Port Mode VLAN   State Vlans
       18             T       1   FWD   111-112
       19             A       1   BLK   1
    ~ # vemcmd show port
    LTL   VSM Port Admin Link State PC-LTL SGID Vem Port
       18               UP   UP   F/B*     0       vmnic1
       19             DOWN   UP   BLK       0       vmnic2
    * F/B: Port is BLOCKED on some of the vlans.
    Please run "vemcmd show port vlans" to see the details.
    ~ # vemcmd show port vlans
                           Native VLAN   Allowed
    LTL   VSM Port Mode VLAN   State Vlans
       18             T       1   FWD   111-112
       19             A       1   BLK   1
    ~ # vemcmd show trunk
    Trunk port 6 native_vlan 1 CBL 1
    vlan(1) cbl 1, vlan(111) cbl 1, vlan(112) cbl 1, vlan(3968) cbl 1, vlan(3969) cbl 1, vlan(3970) cbl 1, vlan(3971) cbl 1,
    Trunk port 16 native_vlan 1 CBL 1
    vlan(1) cbl 1, vlan(111) cbl 1, vlan(112) cbl 1, vlan(3968) cbl 1, vlan(3969) cbl 1, vlan(3970) cbl 1, vlan(3971) cbl 1,
    Trunk port 18 native_vlan 1 CBL 0
    vlan(111) cbl 1, vlan(112) cbl 1,
    ~ # vemcmd show card
    Card UUID type 2: ebd44e72-456b-11e0-0610-00000000108f
    Card name: esx
    Switch name: VSM11
    Switch alias: DvsPortset-0
    Switch uuid: c4 be 2c 50 36 c5 71 97-44 41 1f c0 43 8e 45 78
    Card domain: 1
    Card slot: 1
    VEM Tunnel Mode: L2 Mode
    VEM Control (AIPC) MAC: 00:02:3d:10:01:00
    VEM Packet (Inband) MAC: 00:02:3d:20:01:00
    VEM Control Agent (DPA) MAC: 00:02:3d:40:01:00
    VEM SPAN MAC: 00:02:3d:30:01:00
    Primary VSM MAC : 00:50:56:ac:00:42
    Primary VSM PKT MAC : 00:50:56:ac:00:44
    Primary VSM MGMT MAC : 00:50:56:ac:00:43
    Standby VSM CTRL MAC : ff:ff:ff:ff:ff:ff
    Management IPv4 address: 10.1.240.30
    Management IPv6 address: 0000:0000:0000:0000:0000:0000:0000:0000
    Secondary VSM MAC : 00:00:00:00:00:00
    Secondary L3 Control IPv4 address: 0.0.0.0
    Upgrade : Default
    Max physical ports: 32
    Max virtual ports: 216
    Card control VLAN: 111
    Card packet VLAN: 112
    Card Headless Mode : Yes
           Processors: 8
    Processor Cores: 4
    Processor Sockets: 1
    Kernel Memory:   16712336
    Port link-up delay: 5s
    Global UUFB: DISABLED
    Heartbeat Set: False
    PC LB Algo: source-mac
    Datapath portset event in progress : no
    ~ #
    On VSM
    VSM11# sh svs conn
    connection vcenter:
       ip address: 10.1.240.38
       remote port: 80
       protocol: vmware-vim https
       certificate: default
       datacenter name: New Datacenter
       admin:  
       max-ports: 8192
       DVS uuid: c4 be 2c 50 36 c5 71 97-44 41 1f c0 43 8e 45 78
       config status: Enabled
       operational status: Connected
       sync status: Complete
       version: VMware vCenter Server 4.1.0 build-345043
    VSM11# sh svs ?
    connections Show connection information
    domain       Domain Configuration
    neighbors   Svs neighbors information
    upgrade     Svs upgrade information
    VSM11# sh svs dom
    SVS domain config:
    Domain id:   1  
    Control vlan: 111
    Packet vlan: 112
    L2/L3 Control mode: L2
    L3 control interface: NA
    Status: Config push to VC successful.
    VSM11# sh port
               ^
    % Invalid command at '^' marker.
    VSM11# sh run
    !Command: show running-config
    !Time: Sun Nov 20 11:35:52 2011
    version 4.2(1)SV1(4a)
    feature telnet
    username admin password 5 $1$QhO77JvX$A8ykNUSxMRgqZ0DUUIn381 role network-admin
    banner motd #Nexus 1000v Switch#
    ssh key rsa 2048
    ip domain-lookup
    ip domain-lookup
    hostname VSM11
    snmp-server user admin network-admin auth md5 0x389a68db6dcbd7f7887542ea6f8effa1
    priv 0x389a68db6dcbd7f7887542ea6f8effa1 localizedkey
    vrf context management
    ip route 0.0.0.0/0 10.1.240.254
    vlan 1,111-112
    port-channel load-balance ethernet source-mac
    port-profile default max-ports 32
    port-profile type ethernet Unused_Or_Quarantine_Uplink
    vmware port-group
    shutdown
    description Port-group created for Nexus1000V internal usage. Do not use.
    state enabled
    port-profile type vethernet Unused_Or_Quarantine_Veth
    vmware port-group
    shutdown
    description Port-group created for Nexus1000V internal usage. Do not use.
    state enabled
    port-profile type ethernet system-uplink
    vmware port-group
    switchport mode trunk
    switchport trunk allowed vlan 111-112
    no shutdown
    system vlan 111-112
    description "System profile"
    state enabled
    port-profile type vethernet servers11
    vmware port-group
    switchport mode access
    switchport access vlan 11
    no shutdown
    description "Data Profile for VM Traffic"
    port-profile type ethernet vm-uplink
    vmware port-group
    switchport mode access
    switchport access vlan 11
    no shutdown
    description "Uplink profile for VM traffic"
    state enabled
    vdc VSM11 id 1
    limit-resource vlan minimum 16 maximum 2049
    limit-resource monitor-session minimum 0 maximum 2
    limit-resource vrf minimum 16 maximum 8192
    limit-resource port-channel minimum 0 maximum 768
    limit-resource u4route-mem minimum 32 maximum 32
    limit-resource u6route-mem minimum 16 maximum 16
    limit-resource m4route-mem minimum 58 maximum 58
    limit-resource m6route-mem minimum 8 maximum 8
    interface mgmt0
    ip address 10.1.240.124/24
    interface control0
    line console
    boot kickstart bootflash:/nexus-1000v-kickstart-mz.4.2.1.SV1.4a.bin sup-1
    boot system bootflash:/nexus-1000v-mz.4.2.1.SV1.4a.bin sup-1
    boot kickstart bootflash:/nexus-1000v-kickstart-mz.4.2.1.SV1.4a.bin sup-2
    boot system bootflash:/nexus-1000v-mz.4.2.1.SV1.4a.bin sup-2
    svs-domain
    domain id 1
    control vlan 111
    packet vlan 112
    svs mode L2
    svs connection vcenter
    protocol vmware-vim
    remote ip address 10.1.240.38 port 80
    vmware dvs uuid "c4 be 2c 50 36 c5 71 97-44 41 1f c0 43 8e 45 78" datacenter-n
    ame New Datacenter
    max-ports 8192
    connect
    vsn type vsg global
    tcp state-checks
    vnm-policy-agent
    registration-ip 0.0.0.0
    shared-secret **********
    log-level
    thank you
    Michel

  • Nexus 1000v VEM module bouncing between hosts

    I'm receiving these error messages on my N1KV and don't know how to fix it.  I've tried removing, rebooting, reinstalling host B's VEM but that did not fix the issue.  How do I debug this?
    My setup,
    Two physical hosts running esxi 5.1, vcenter appliance, n1kv with two system uplinks and two uplinks for iscsi for each host.  Let me know if you need more output from logs or commands, thanks.
    N1KV# 2013 Jun 17 18:18:07 N1KV %VEM_MGR-2-VEM_MGR_DETECTED: Host 192.168.52.100 detected as module 3
    2013 Jun 17 18:18:07 N1KV %VEM_MGR-2-MOD_ONLINE: Module 3 is online
    2013 Jun 17 18:18:08 N1KV %VEM_MGR-2-VEM_MGR_REMOVE_UNEXP_NODEID_REQ: Removing VEM 3 (Unexpected Node Id Request)
    2013 Jun 17 18:18:09 N1KV %VEM_MGR-2-MOD_OFFLINE: Module 3 is offline
    2013 Jun 17 18:18:13 N1KV %VEM_MGR-2-VEM_MGR_DETECTED: Host 192.168.51.100 detected as module 3
    2013 Jun 17 18:18:13 N1KV %VEM_MGR-2-MOD_ONLINE: Module 3 is online
    2013 Jun 17 18:18:16 N1KV %VEM_MGR-2-VEM_MGR_REMOVE_UNEXP_NODEID_REQ: Removing VEM 3 (Unexpected Node Id Request)
    2013 Jun 17 18:18:17 N1KV %VEM_MGR-2-MOD_OFFLINE: Module 3 is offline
    2013 Jun 17 18:18:21 N1KV %VEM_MGR-2-VEM_MGR_DETECTED: Host 192.168.52.100 detected as module 3
    2013 Jun 17 18:18:21 N1KV %VEM_MGR-2-MOD_ONLINE: Module 3 is online
    2013 Jun 17 18:18:22 N1KV %VEM_MGR-2-VEM_MGR_REMOVE_UNEXP_NODEID_REQ: Removing VEM 3 (Unexpected Node Id Request)
    2013 Jun 17 18:18:23 N1KV %VEM_MGR-2-MOD_OFFLINE: Module 3 is offline
    2013 Jun 17 18:18:28 N1KV %VEM_MGR-2-VEM_MGR_DETECTED: Host 192.168.51.100 detected as module 3
    2013 Jun 17 18:18:29 N1KV %VEM_MGR-2-MOD_ONLINE: Module 3 is online
    2013 Jun 17 18:18:44 N1KV %PLATFORM-2-MOD_DETECT: Module 2 detected (Serial number :unavailable) Module-Type Virtual Supervisor Module Model :unavailable
    N1KV# sh module
    Mod  Ports  Module-Type                       Model               Status
    1    0      Virtual Supervisor Module         Nexus1000V          ha-standby
    2    0      Virtual Supervisor Module         Nexus1000V          active *
    3    248    Virtual Ethernet Module           NA                  ok
    Mod  Sw                  Hw     
    1    4.2(1)SV2(1.1a)     0.0                                             
    2    4.2(1)SV2(1.1a)     0.0                                             
    3    4.2(1)SV2(1.1a)     VMware ESXi 5.1.0 Releasebuild-838463 (3.1)     
    Mod  MAC-Address(es)                         Serial-Num
    1    00-19-07-6c-5a-a8 to 00-19-07-6c-62-a8  NA
    2    00-19-07-6c-5a-a8 to 00-19-07-6c-62-a8  NA
    3    02-00-0c-00-03-00 to 02-00-0c-00-03-80  NA
    Mod  Server-IP        Server-UUID                           Server-Name
    1    192.168.54.2     NA                                    NA
    2    192.168.54.2     NA                                    NA
    3    192.168.51.100   03000200-0400-0500-0006-000700080009  NA
    * this terminal session
    ~ # vemcmd show card
    Card UUID type  2: 03000200-0400-0500-0006-000700080009
    Card name:
    Switch name: N1KV
    Switch alias: DvsPortset-1
    Switch uuid: e6 dc 36 50 c0 a9 d9 a5-0b 98 fb 90 e1 fc 99 af
    Card domain: 2
    Card slot: 3
    VEM Tunnel Mode: L3 Mode
    L3 Ctrl Index: 49
    L3 Ctrl VLAN: 51
    VEM Control (AIPC) MAC: 00:02:3d:10:02:02
    VEM Packet (Inband) MAC: 00:02:3d:20:02:02
    VEM Control Agent (DPA) MAC: 00:02:3d:40:02:02
    VEM SPAN MAC: 00:02:3d:30:02:02
    Primary VSM MAC : 00:50:56:b6:0c:b2
    Primary VSM PKT MAC : 00:50:56:b6:35:3f
    Primary VSM MGMT MAC : 00:50:56:b6:d5:12
    Standby VSM CTRL MAC : 00:50:56:b6:96:f2
    Management IPv4 address: 192.168.51.100
    Management IPv6 address: 0000:0000:0000:0000:0000:0000:0000:0000
    Primary L3 Control IPv4 address: 192.168.54.2
    Secondary VSM MAC : 00:00:00:00:00:00
    Secondary L3 Control IPv4 address: 0.0.0.0
    Upgrade : Default
    Max physical ports: 32
    Max virtual ports: 216
    Card control VLAN: 1
    Card packet VLAN: 1
    Control type multicast: No
    Card Headless Mode : No
           Processors: 4
      Processor Cores: 4
    Processor Sockets: 1
      Kernel Memory:   16669760
    Port link-up delay: 5s
    Global UUFB: DISABLED
    Heartbeat Set: True
    PC LB Algo: source-mac
    Datapath portset event in progress : no
    Licensed: Yes
    ~ # vemcmd show card
    Card UUID type  2: 03000200-0400-0500-0006-000700080009
    Card name:
    Switch name: N1KV
    Switch alias: DvsPortset-0
    Switch uuid: e6 dc 36 50 c0 a9 d9 a5-0b 98 fb 90 e1 fc 99 af
    Card domain: 2
    Card slot: 3
    VEM Tunnel Mode: L3 Mode
    L3 Ctrl Index: 49
    L3 Ctrl VLAN: 52
    VEM Control (AIPC) MAC: 00:02:3d:10:02:02
    VEM Packet (Inband) MAC: 00:02:3d:20:02:02
    VEM Control Agent (DPA) MAC: 00:02:3d:40:02:02
    VEM SPAN MAC: 00:02:3d:30:02:02
    Primary VSM MAC : 00:50:56:b6:0c:b2
    Primary VSM PKT MAC : 00:50:56:b6:35:3f
    Primary VSM MGMT MAC : 00:50:56:b6:d5:12
    Standby VSM CTRL MAC : 00:50:56:b6:96:f2
    Management IPv4 address: 192.168.52.100
    Management IPv6 address: 0000:0000:0000:0000:0000:0000:0000:0000
    Primary L3 Control IPv4 address: 192.168.54.2
    Secondary VSM MAC : 00:00:00:00:00:00
    Secondary L3 Control IPv4 address: 0.0.0.0
    Upgrade : Default
    Max physical ports: 32
    Max virtual ports: 216
    Card control VLAN: 1
    Card packet VLAN: 1
    Control type multicast: No
    Card Headless Mode : Yes
           Processors: 4
      Processor Cores: 4
    Processor Sockets: 1
      Kernel Memory:   16669764
    Port link-up delay: 5s
    Global UUFB: DISABLED
    Heartbeat Set: False
    PC LB Algo: source-mac
    Datapath portset event in progress : no
    Licensed: Yes
    ! ports 1-6 connected to physical host A
    interface GigabitEthernet1/0/1
    description VMWARE ESXi Trunk
    switchport trunk encapsulation dot1q
    switchport mode trunk
    switchport nonegotiate
    spanning-tree portfast trunk
    spanning-tree bpdufilter enable
    spanning-tree bpduguard enable
    channel-group 1 mode active
    ! ports 7-12 connected to phys host B
    interface GigabitEthernet1/0/7
    description VMWARE ESXi Trunk
    switchport trunk encapsulation dot1q
    switchport mode trunk
    switchport nonegotiate
    spanning-tree portfast trunk
    spanning-tree bpdufilter enable
    spanning-tree bpduguard enable
    channel-group 2 mode active

    ok after deleteing the n1kv vms and vcenter and then reinstalling all I got the error again,
    N1KV# 2013 Jun 18 17:48:12 N1KV %VEM_MGR-2-VEM_MGR_REMOVE_STATE_CONFLICT: Removing VEM 3 due to state conflict VSM(NodeId Processed), VEM(ModIns End Rcvd)
    2013 Jun 18 17:48:13 N1KV %VEM_MGR-2-MOD_OFFLINE: Module 3 is offline
    2013 Jun 18 17:48:16 N1KV %VEM_MGR-2-VEM_MGR_DETECTED: Host 192.168.52.100 detected as module 3
    2013 Jun 18 17:48:16 N1KV %VEM_MGR-2-MOD_ONLINE: Module 3 is online
    2013 Jun 18 17:48:22 N1KV %VEM_MGR-2-VEM_MGR_REMOVE_STATE_CONFLICT: Removing VEM 3 due to state conflict VSM(NodeId Processed), VEM(ModIns End Rcvd)
    2013 Jun 18 17:48:23 N1KV %VEM_MGR-2-MOD_OFFLINE: Module 3 is offline
    2013 Jun 18 17:48:34 N1KV %VEM_MGR-2-VEM_MGR_DETECTED: Host 192.168.52.100 detected as module 3
    2013 Jun 18 17:48:34 N1KV %VEM_MGR-2-MOD_ONLINE: Module 3 is online
    2013 Jun 18 17:48:41 N1KV %VEM_MGR-2-VEM_MGR_REMOVE_STATE_CONFLICT: Removing VEM 3 due to state conflict VSM(NodeId Processed), VEM(ModIns End Rcvd)
    2013 Jun 18 17:48:42 N1KV %VEM_MGR-2-MOD_OFFLINE: Module 3 is offline
    2013 Jun 18 17:49:03 N1KV %VEM_MGR-2-VEM_MGR_DETECTED: Host 192.168.52.100 detected as module 3
    2013 Jun 18 17:49:03 N1KV %VEM_MGR-2-MOD_ONLINE: Module 3 is online
    2013 Jun 18 17:49:10 N1KV %VEM_MGR-2-VEM_MGR_REMOVE_STATE_CONFLICT: Removing VEM 3 due to state conflict VSM(NodeId Processed), VEM(ModIns End Rcvd)
    2013 Jun 18 17:49:11 N1KV %VEM_MGR-2-MOD_OFFLINE: Module 3 is offline
    2013 Jun 18 17:49:29 N1KV %VEM_MGR-2-VEM_MGR_DETECTED: Host 192.168.51.100 detected as module 3
    2013 Jun 18 17:49:29 N1KV %VEM_MGR-2-MOD_ONLINE: Module 3 is online
    2013 Jun 18 17:49:35 N1KV %VEM_MGR-2-VEM_MGR_REMOVE_STATE_CONFLICT: Removing VEM 3 due to state conflict VSM(NodeId Processed), VEM(ModIns End Rcvd)
    2013 Jun 18 17:49:36 N1KV %VEM_MGR-2-MOD_OFFLINE: Module 3 is offline
    2013 Jun 18 17:49:53 N1KV %VEM_MGR-2-VEM_MGR_DETECTED: Host 192.168.51.100 detected as module 3
    2013 Jun 18 17:49:53 N1KV %VEM_MGR-2-MOD_ONLINE: Module 3 is online
    2013 Jun 18 17:49:59 N1KV %VEM_MGR-2-VEM_MGR_REMOVE_STATE_CONFLICT: Removing VEM 3 due to state conflict VSM(NodeId Processed), VEM(ModIns End Rcvd)
    2013 Jun 18 17:50:00 N1KV %VEM_MGR-2-MOD_OFFLINE: Module 3 is offline
    2013 Jun 18 17:50:05 N1KV %VEM_MGR-2-VEM_MGR_DETECTED: Host 192.168.52.100 detected as module 3
    2013 Jun 18 17:50:05 N1KV %VEM_MGR-2-MOD_ONLINE: Module 3 is online
    Host A
    ~ # vemcmd show card
    Card UUID type  2: 03000200-0400-0500-0006-000700080009
    Card name:
    Switch name: N1KV
    Switch alias: DvsPortset-0
    Switch uuid: e6 dc 36 50 c0 a9 d9 a5-0b 98 fb 90 e1 fc 99 af
    Card domain: 2
    Card slot: 1
    VEM Tunnel Mode: L3 Mode
    L3 Ctrl Index: 49
    L3 Ctrl VLAN: 52
    VEM Control (AIPC) MAC: 00:02:3d:10:02:00
    VEM Packet (Inband) MAC: 00:02:3d:20:02:00
    VEM Control Agent (DPA) MAC: 00:02:3d:40:02:00
    VEM SPAN MAC: 00:02:3d:30:02:00
    Primary VSM MAC : 00:50:56:b6:96:f2
    Primary VSM PKT MAC : 00:50:56:b6:11:b6
    Primary VSM MGMT MAC : 00:50:56:b6:48:c6
    Standby VSM CTRL MAC : ff:ff:ff:ff:ff:ff
    Management IPv4 address: 192.168.52.100
    Management IPv6 address: 0000:0000:0000:0000:0000:0000:0000:0000
    Primary L3 Control IPv4 address: 192.168.54.2
    Secondary VSM MAC : 00:00:00:00:00:00
    Secondary L3 Control IPv4 address: 0.0.0.0
    Upgrade : Default
    Max physical ports: 32
    Max virtual ports: 216
    Card control VLAN: 1
    Card packet VLAN: 1
    Control type multicast: No
    Card Headless Mode : Yes
           Processors: 4
      Processor Cores: 4
    Processor Sockets: 1
      Kernel Memory:   16669764
    Port link-up delay: 5s
    Global UUFB: DISABLED
    Heartbeat Set: False
    PC LB Algo: source-mac
    Datapath portset event in progress : no
    Licensed: No
    Host B
    ~ # vemcmd show card
    Card UUID type  2: 03000200-0400-0500-0006-000700080009
    Card name:
    Switch name: N1KV
    Switch alias: DvsPortset-0
    Switch uuid: bf fb 28 50 1b 26 dd ae-05 bd 4e 48 2e 37 56 f3
    Card domain: 2
    Card slot: 3
    VEM Tunnel Mode: L3 Mode
    L3 Ctrl Index: 49
    L3 Ctrl VLAN: 51
    VEM Control (AIPC) MAC: 00:02:3d:10:02:02
    VEM Packet (Inband) MAC: 00:02:3d:20:02:02
    VEM Control Agent (DPA) MAC: 00:02:3d:40:02:02
    VEM SPAN MAC: 00:02:3d:30:02:02
    Primary VSM MAC : 00:50:56:a8:f5:f0
    Primary VSM PKT MAC : 00:50:56:a8:3c:62
    Primary VSM MGMT MAC : 00:50:56:a8:b4:a4
    Standby VSM CTRL MAC : 00:50:56:a8:30:d5
    Management IPv4 address: 192.168.51.100
    Management IPv6 address: 0000:0000:0000:0000:0000:0000:0000:0000
    Primary L3 Control IPv4 address: 192.168.54.2
    Secondary VSM MAC : 00:00:00:00:00:00
    Secondary L3 Control IPv4 address: 0.0.0.0
    Upgrade : Default
    Max physical ports: 32
    Max virtual ports: 216
    Card control VLAN: 1
    Card packet VLAN: 1
    Control type multicast: No
    Card Headless Mode : No
           Processors: 4
      Processor Cores: 4
    Processor Sockets: 1
      Kernel Memory:   16669760
    Port link-up delay: 5s
    Global UUFB: DISABLED
    Heartbeat Set: True
    PC LB Algo: source-mac
    Datapath portset event in progress : no
    Licensed: Yes
    I used the nexus 1000v java installer so I don't know what it keeps assigning the same UUID nor do I know how to change it.
    Here is the other output you requested,
    N1KV# show vms internal info dvs
      DVS INFO:
    DVS name: [N1KV]
          UUID: [bf fb 28 50 1b 26 dd ae-05 bd 4e 48 2e 37 56 f3]
          Description: [(null)]
          Config version: [1]
          Max ports: [8192]
          DC name: [Galaxy]
         OPQ data: size [1121], data: [data-version 1.0
    switch-domain 2
    switch-name N1KV
    cp-version 4.2(1)SV2(1.1a)
    control-vlan 1
    system-primary-mac 00:50:56:a8:f5:f0
    active-vsm packet mac 00:50:56:a8:3c:62
    active-vsm mgmt mac 00:50:56:a8:b4:a4
    standby-vsm ctrl mac 0050-56a8-30d5
    inband-vlan 1
    svs-mode L3
    l3control-ipaddr 192.168.54.2
    upgrade state 0 mac 0050-56a8-30d5 l3control-ipv4 null
    cntl-type-mcast 0
    profile dvportgroup-26 trunk 1,51-57,110
    profile dvportgroup-26 mtu 9000
    profile dvportgroup-27 access 51
    profile dvportgroup-27 mtu 1500
    profile dvportgroup-27 capability l3control
    profile dvportgroup-28 access 52
    profile dvportgroup-28 mtu 1500
    profile dvportgroup-28 capability l3control
    profile dvportgroup-29 access 53
    profile dvportgroup-29 mtu 1500
    profile dvportgroup-30 access 54
    profile dvportgroup-30 mtu 1500
    profile dvportgroup-31 access 55
    profile dvportgroup-31 mtu 1500
    profile dvportgroup-32 access 56
    profile dvportgroup-32 mtu 1500
    profile dvportgroup-34 trunk 220
    profile dvportgroup-34 mtu 9000
    profile dvportgroup-35 access 220
    profile dvportgroup-35 mtu 1500
    profile dvportgroup-35 capability iscsi-multipath
    end-version 1.0
          push_opq_data flag: [1]
    show svs neighbors
    Active Domain ID: 2
    AIPC Interface MAC: 0050-56a8-f5f0
    Inband Interface MAC: 0050-56a8-3c62
    Src MAC           Type   Domain-id    Node-id     Last learnt (Sec. ago)
    0050-56a8-30d5     VSM         2         0201      1020.45
    0002-3d40-0202     VEM         2         0302         1.33
    I cannot add Host A to the N1KV it errors out with,
    vDS operation failed on host 192.168.52.100, An error occurred during host configuration. got (vim.fault.PlatformConfigFault) exception
    Host B (192.168.51.100) was added fine, then I moved a vmkernel to the N1KV which brought up the VEM and got the VEM flapping errors.

  • SNMP Polling from UCS Manager 1.4

    I am having trouble with SNMP Polling from UCS Manager 1.4(1j).
    I seem to only get SNMP data from Nexus such as those described in (http://www.cisco.com/en/US/docs/switches/datacenter/nexus5000/sw/mib/reference/NX5000_MIBRef.html) I don't see any OIDs corresponding to those mentioned specifically for UCS listed in (ftp://ftp.cisco.com/pub/mibs/supportlists/ucs/ucs-manager-supportlist.html).
    Documentation on the cisco web site said that UCS Manager 1.4(1) and above will have MIBS such as CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB available.
    Is there a separate IP addresses I should poll for these or any specific things that need to be set up?
    I am not sure how we can gain access to the UCS related MIB objects exactly. The description on SNMP enable for UCS Manager is very brief (http://www.cisco.com/en/US/docs/unified_computing/ucs/sw/gui/config/guide/1.4/UCSM_GUI_Configuration_Guide_1_4_chapter6.html#task_2054446421216050764)
    It only described the community string set up under UCS Manager ->Admin->Communication Management -> Communication Services, bu didn’t really say anything about which IP addresses from the Management Interfaces should be used to get them.
    Has anyone successfully polled data from say the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB and be able to help?
    Thanks in advance.

    Yes indeed.
    I learnt about the CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB and the other Cisco UCS Manager MIB Support list by selecting UCS Manager under the Unified Computing drop down on this http page you quoted.
    (http://www.cisco.com/en/US/docs/unified_computing/ucs/sw/mib/reference/UCS_MIBRef.html)
    Is there anything specific from those docs you are referring to that would make it such that we get the Nexus MIBs rather than ones under UCS Manager?
    The two IP addresses for Fabric Interconnect A and B under Management Interface only give us info from MIBs listed under the Nexus documentation only. Nothing fir say 1.3.6.1.4.1.9.9.719.1.15.
    No SNMP data form the virtual IP address.
    Not sure where data under 1.3.6.1.4.1.9.9.719.1.15 would be accessible

  • Nexus 1010 and Management

    it is the first time that i install and configure a Nexus 1010.
    After unpackaging, i have upgrade the BIOS, CMC and Firmware of the nexus 1010 (like a classical C-serie server)
    The CIMC 's @IP is 10.10.0.100 ; I have connected the 10/100 Ethernet CIMC management port to my OOB  network where we have all OOB interfaces from Nx7k and Nx5k.
    Now i would want configure the Nx1010 in the topology "uplink type 3".
    port 1 and 2 : mangement Vlan
    port 3 to 6 : Control/packt Vlan and Data Vlan.
    In the setup wizard, we have to configure the int Mgmt0 of Nx 1010.
    In which network must be the Mgmt0 ; i am confused and mix up :
    - CIMC mgmt from the C-series server
    - mgmt0 int from nexus 1010 : by which physical interface goes throught this traffic : via "10/100 Ethernet CIMC management port" or via "Management vlan" ???
    - Vlan management : this Vlan will allow to manager the VSB VSM-1 et VSM-2....
    The Vlan management must not be the OOB network, must it ?
    It is not clear for my mind ; i mix up all this mgmt
    please help me !!!
    many thank in advance.
    NB : All the devices in our DC (Nx5k and Nx5K/Nx2K) have two management interface :
    1 - OOB management via the pysical OOB port
    2 - Inb management via a dedicated Vlan ; each device have 1 @IP in this Vlan (even the L2 Nx7k (without M1 card) via the cli "management")
    How could i have the these mgmt for Nexus 1010 / CIMC / VSM ???
    Last question : in order to upgrade the nx 1010, then download the nexus-1000v*.iso to bootflash:repository, which network/mgmt i have to used ???

    Hi Delahais, could you resolve your concern? .. I have the same doubt

  • VM-FEX and Nexus 1000v relation

    Hi
    I am a new in virtulaization world and I need to know what is the relation between Cisco Nexus 1000v and Cisco VM-FEX?, and when to use VM-FEX and when to use Nexus 1000v.
    Regards

    Ahmed,
    Sorry for taking this long to get back to you.
    Nexus 1000v is a virtualized switch and as such will require that any traffic coming in or leaving the VM will first need to pass through the virtualization layer, therefore causing a minimum delay that for some applications (VMs) can be catastrophic enough that may mean too much delay.
    With VM-FEX you gain the option to bypass the virtualization layer with for example "Pass-Through" mode where the vmnics are really assigned and managed by the OS, minimizing the delay and making the VMs look as if they were directly attached, also, this offloads CPU workload in the mean time, optimizing the host/VM's performance.
    The need for one or the other will be defined as always by the needs your organization/business has.
    Benefits of VM-FEX (from cisco.com):
    Simplified operations: Eliminates the need for a separate, virtual networking infrastructure
    Improved network security: Contains VLAN proliferation
    Optimized network utilization: Reduces broadcast domains
    Enhanced application performance: Offloads virtual  machine switching from host CPU to parent switch application-specific  integrated circuits (ASICs)
    Benefits of Nexus 1000v here on another post from Rob Burns:
    https://supportforums.cisco.com/thread/2087541 
    https://communities.vmware.com/thread/316542?tstart=0
    I hope that helps 
    -Kenny

  • Install Cisco Nexus 1000V without vCenter?

    Hi guys,
    Is this possible that we install nexus 1000v without using vcenter?
    I have vmware enterprise plus license, but I don't need to install vcenter.
    Regards,

    No, one of the features of the Enterprise Plus licenses provides are VMware & 3rd Party Distributed Virtual Switch functionality.  This requires vCenter to manage them.
    Regards,
    Robert

  • Software ASA Similar To Nexus 1000v

    Hello,
    I was wondering if Cisco has a software version of the ASA similar to the Nexus 1000v I could run in a VM for UCS?
    Thanks

    There's a vASA coming out.  This will be a fully featured virtual version of today's ASA product.  Not sure the exact release date, but should be later this year.
    Regards,
    Robert

Maybe you are looking for

  • Need assistance - wired PC doesn't "see" AEBS; PC notebook and macbooks do

    Hi everyone. I'm hoping someone will be able to help me with the last step in putting together our home network. I'm certainly not a networking expert by any means, but I've been able to get the wireless aspects of the network (Internet, wireless pri

  • PSE10: Table keystroke sequence to clear a layer?

    Hi, I'm trying to use CTRL+A;Delete;CTRL+D key combination in order to clear the content of the active layer. When I'm doing it manually via the keyboard, the results are as expected. But when I feed this and a sequence of keystrokes to one of my Wac

  • Cfmail - nesting error message

    Greetings - Perhaps someone can shed some light on why the following is occurring. I have a processing page processing form input for a event registration. The process works fine, displays as intended on a web page. However, when i enclose the code i

  • Commas or Points (, or .) in BIP on the WEB

    Hi, I'm using BIP (NW04s SP15). I've created a query and web template that are input ready. I wan't to use . (point) as the decimal separator, bvut now it's using commas (,). I've changed my user profile via SAPGUI using transaction SU3, so my decima

  • How do i move aperture library to from MBP external drive

    Perhaps I am not searching properly,but was unable to bring up a 2011 answer to this question. Does anyone have more current help than 2011?