[Nexus 1000v] VEM can't be add into VSM

hi all,
following my lab, i have some problems with Nexus 1000V when VEM can't be add into VSM.
+ on VSM has already installed on ESX 1 (standalone or ha) and you can see:
Cisco_N1KV# show module
Mod  Ports  Module-Type                       Model               Status
1    0      Virtual Supervisor Module         Nexus1000V          active *
Mod  Sw                Hw
1    4.2(1)SV1(4a)     0.0
Mod  MAC-Address(es)                         Serial-Num
1    00-19-07-6c-5a-a8 to 00-19-07-6c-62-a8  NA
Mod  Server-IP        Server-UUID                           Server-Name
1    10.4.110.123     NA                                    NA
+ on ESX2 that 's installed VEM
[root@esxhoadq ~]# vem status
VEM modules are loaded
Switch Name      Num Ports   Used Ports  Configured Ports  MTU     Uplinks
vSwitch0         128         3           128               1500    vmnic0
VEM Agent (vemdpa) is running
[root@esxhoadq ~]#
any advices for this,
thanks so much

Hi,
i'm having similar issue: the VEM insatlled on the ESXi is not showing up on the VSM.
please check from the following what can be wrong?
This is the VEM status:
~ # vem status -v
Package vssnet-esx5.5.0-00000-release
Version 4.2.1.1.4.1.0-2.0.1
Build 1
Date Wed Jul 27 04:42:14 PDT 2011
Number of PassThru NICs are 0
VEM modules are loaded
Switch Name     Num Ports   Used Ports Configured Ports MTU     Uplinks  
vSwitch0         128         4           128               1500   vmnic0  
DVS Name         Num Ports   Used Ports Configured Ports MTU     Uplinks  
VSM11           256         40         256               1500   vmnic2,vmnic1
Number of PassThru NICs are 0
VEM Agent (vemdpa) is running
~ # vemcmd show port    
LTL   VSM Port Admin Link State PC-LTL SGID Vem Port
   18               UP   UP   F/B*     0       vmnic1
   19             DOWN   UP   BLK       0       vmnic2
* F/B: Port is BLOCKED on some of the vlans.
Please run "vemcmd show port vlans" to see the details.
~ # vemcmd show trunk
Trunk port 6 native_vlan 1 CBL 1
vlan(1) cbl 1, vlan(111) cbl 1, vlan(112) cbl 1, vlan(3968) cbl 1, vlan(3969) cbl 1, vlan(3970) cbl 1, vlan(3971) cbl 1,
Trunk port 16 native_vlan 1 CBL 1
vlan(1) cbl 1, vlan(111) cbl 1, vlan(112) cbl 1, vlan(3968) cbl 1, vlan(3969) cbl 1, vlan(3970) cbl 1, vlan(3971) cbl 1,
Trunk port 18 native_vlan 1 CBL 0
vlan(111) cbl 1, vlan(112) cbl 1,
~ # vemcmd show port
LTL   VSM Port Admin Link State PC-LTL SGID Vem Port
   18               UP   UP   F/B*     0       vmnic1
   19            DOWN   UP   BLK       0       vmnic2
* F/B: Port is BLOCKED on some of the vlans.
Please run "vemcmd show port vlans" to see the details.
~ # vemcmd show port vlans
                       Native VLAN   Allowed
LTL   VSM Port Mode VLAN   State Vlans
   18             T       1   FWD   111-112
   19             A       1   BLK   1
~ # vemcmd show port
LTL   VSM Port Admin Link State PC-LTL SGID Vem Port
   18               UP   UP   F/B*     0       vmnic1
   19             DOWN   UP   BLK       0       vmnic2
* F/B: Port is BLOCKED on some of the vlans.
Please run "vemcmd show port vlans" to see the details.
~ # vemcmd show port vlans
                       Native VLAN   Allowed
LTL   VSM Port Mode VLAN   State Vlans
   18             T       1   FWD   111-112
   19             A       1   BLK   1
~ # vemcmd show trunk
Trunk port 6 native_vlan 1 CBL 1
vlan(1) cbl 1, vlan(111) cbl 1, vlan(112) cbl 1, vlan(3968) cbl 1, vlan(3969) cbl 1, vlan(3970) cbl 1, vlan(3971) cbl 1,
Trunk port 16 native_vlan 1 CBL 1
vlan(1) cbl 1, vlan(111) cbl 1, vlan(112) cbl 1, vlan(3968) cbl 1, vlan(3969) cbl 1, vlan(3970) cbl 1, vlan(3971) cbl 1,
Trunk port 18 native_vlan 1 CBL 0
vlan(111) cbl 1, vlan(112) cbl 1,
~ # vemcmd show card
Card UUID type 2: ebd44e72-456b-11e0-0610-00000000108f
Card name: esx
Switch name: VSM11
Switch alias: DvsPortset-0
Switch uuid: c4 be 2c 50 36 c5 71 97-44 41 1f c0 43 8e 45 78
Card domain: 1
Card slot: 1
VEM Tunnel Mode: L2 Mode
VEM Control (AIPC) MAC: 00:02:3d:10:01:00
VEM Packet (Inband) MAC: 00:02:3d:20:01:00
VEM Control Agent (DPA) MAC: 00:02:3d:40:01:00
VEM SPAN MAC: 00:02:3d:30:01:00
Primary VSM MAC : 00:50:56:ac:00:42
Primary VSM PKT MAC : 00:50:56:ac:00:44
Primary VSM MGMT MAC : 00:50:56:ac:00:43
Standby VSM CTRL MAC : ff:ff:ff:ff:ff:ff
Management IPv4 address: 10.1.240.30
Management IPv6 address: 0000:0000:0000:0000:0000:0000:0000:0000
Secondary VSM MAC : 00:00:00:00:00:00
Secondary L3 Control IPv4 address: 0.0.0.0
Upgrade : Default
Max physical ports: 32
Max virtual ports: 216
Card control VLAN: 111
Card packet VLAN: 112
Card Headless Mode : Yes
       Processors: 8
Processor Cores: 4
Processor Sockets: 1
Kernel Memory:   16712336
Port link-up delay: 5s
Global UUFB: DISABLED
Heartbeat Set: False
PC LB Algo: source-mac
Datapath portset event in progress : no
~ #
On VSM
VSM11# sh svs conn
connection vcenter:
   ip address: 10.1.240.38
   remote port: 80
   protocol: vmware-vim https
   certificate: default
   datacenter name: New Datacenter
   admin:  
   max-ports: 8192
   DVS uuid: c4 be 2c 50 36 c5 71 97-44 41 1f c0 43 8e 45 78
   config status: Enabled
   operational status: Connected
   sync status: Complete
   version: VMware vCenter Server 4.1.0 build-345043
VSM11# sh svs ?
connections Show connection information
domain       Domain Configuration
neighbors   Svs neighbors information
upgrade     Svs upgrade information
VSM11# sh svs dom
SVS domain config:
Domain id:   1  
Control vlan: 111
Packet vlan: 112
L2/L3 Control mode: L2
L3 control interface: NA
Status: Config push to VC successful.
VSM11# sh port
           ^
% Invalid command at '^' marker.
VSM11# sh run
!Command: show running-config
!Time: Sun Nov 20 11:35:52 2011
version 4.2(1)SV1(4a)
feature telnet
username admin password 5 $1$QhO77JvX$A8ykNUSxMRgqZ0DUUIn381 role network-admin
banner motd #Nexus 1000v Switch#
ssh key rsa 2048
ip domain-lookup
ip domain-lookup
hostname VSM11
snmp-server user admin network-admin auth md5 0x389a68db6dcbd7f7887542ea6f8effa1
priv 0x389a68db6dcbd7f7887542ea6f8effa1 localizedkey
vrf context management
ip route 0.0.0.0/0 10.1.240.254
vlan 1,111-112
port-channel load-balance ethernet source-mac
port-profile default max-ports 32
port-profile type ethernet Unused_Or_Quarantine_Uplink
vmware port-group
shutdown
description Port-group created for Nexus1000V internal usage. Do not use.
state enabled
port-profile type vethernet Unused_Or_Quarantine_Veth
vmware port-group
shutdown
description Port-group created for Nexus1000V internal usage. Do not use.
state enabled
port-profile type ethernet system-uplink
vmware port-group
switchport mode trunk
switchport trunk allowed vlan 111-112
no shutdown
system vlan 111-112
description "System profile"
state enabled
port-profile type vethernet servers11
vmware port-group
switchport mode access
switchport access vlan 11
no shutdown
description "Data Profile for VM Traffic"
port-profile type ethernet vm-uplink
vmware port-group
switchport mode access
switchport access vlan 11
no shutdown
description "Uplink profile for VM traffic"
state enabled
vdc VSM11 id 1
limit-resource vlan minimum 16 maximum 2049
limit-resource monitor-session minimum 0 maximum 2
limit-resource vrf minimum 16 maximum 8192
limit-resource port-channel minimum 0 maximum 768
limit-resource u4route-mem minimum 32 maximum 32
limit-resource u6route-mem minimum 16 maximum 16
limit-resource m4route-mem minimum 58 maximum 58
limit-resource m6route-mem minimum 8 maximum 8
interface mgmt0
ip address 10.1.240.124/24
interface control0
line console
boot kickstart bootflash:/nexus-1000v-kickstart-mz.4.2.1.SV1.4a.bin sup-1
boot system bootflash:/nexus-1000v-mz.4.2.1.SV1.4a.bin sup-1
boot kickstart bootflash:/nexus-1000v-kickstart-mz.4.2.1.SV1.4a.bin sup-2
boot system bootflash:/nexus-1000v-mz.4.2.1.SV1.4a.bin sup-2
svs-domain
domain id 1
control vlan 111
packet vlan 112
svs mode L2
svs connection vcenter
protocol vmware-vim
remote ip address 10.1.240.38 port 80
vmware dvs uuid "c4 be 2c 50 36 c5 71 97-44 41 1f c0 43 8e 45 78" datacenter-n
ame New Datacenter
max-ports 8192
connect
vsn type vsg global
tcp state-checks
vnm-policy-agent
registration-ip 0.0.0.0
shared-secret **********
log-level
thank you
Michel

Similar Messages

  • Nexus 1000V VEM Issues

    I am having some problems with VSM/VEM connectivity after an upgrade that I'm hoping someone can help with.
    I have a 2 ESXi host cluster that I am upgrading from vSphere 5.0 to 5.5u1, and upgrading a Nexus 1000V from SV2(2.1) to SV2(2.2).  I upgraded vCenter without issue (I'm using the vCSA), but when I attempted to upgrade ESXi-1 to 5.5u1 using VUM it complained that a VIB was incompatible.  After tracing this VIB to the 1000V VEM, I created an ESXi 5.5u1 installer package containing the SV2(2.2) VEM VIB for ESXi 5.5 and attempted to use VUM again but was still unsuccessful
    I removed the VEM VIB from the vDS and the host and was able to upgrade the host to 5.5u1.  I tried to add it back to the vDS and was given the error below:
    vDS operation failed on host esxi1, Received SOAP response fault from [<cs p:00007fa5d778d290, TCP:esxi1.gooch.net:443>]: invokeHostTransactionCall
    Received SOAP response fault from [<cs p:1f3cee20, TCP:localhost:8307>]: invokeHostTransactionCall
    An error occurred during host configuration. got (vim.fault.PlatformConfigFault) exception
    I installed the VEM VIB manually at the CLI with 'esxcli software vib install -d /tmp/cisco-vem-v164-4.2.1.2.2.2.0-3.2.1.zip' and I'm able to add to to the vDS, but when I connect the uplinks and migrate the L3 Control VMKernel, I get the following error where it complains about the SPROM when the module comes online, then it eventually drops the VEM.
    2014 Mar 29 15:34:54 n1kv %VEM_MGR-2-VEM_MGR_DETECTED: Host esxi1 detected as module 3
    2014 Mar 29 15:34:54 n1kv %VDC_MGR-2-VDC_CRITICAL: vdc_mgr has hit a critical error: SPROM data is invalid. Please reprogram your SPROM!
    2014 Mar 29 15:34:54 n1kv %VEM_MGR-2-MOD_ONLINE: Module 3 is online
    2014 Mar 29 15:37:14 n1kv %VEM_MGR-2-VEM_MGR_REMOVE_NO_HB: Removing VEM 3 (heartbeats lost)
    2014 Mar 29 15:37:19 n1kv %STP-2-SET_PORT_STATE_FAIL: Port state change req to PIXM failed, status = 0x41e80001 [failure] vdc 1, tree id 0, num ports 1, ports  state BLK, opcode MTS_OPC_PIXM_SET_MULT_CBL_VLAN_BM_FOR_MULT_PORTS, msg id (2274781), rr_token 0x22B5DD
    2014 Mar 29 15:37:21 n1kv %VEM_MGR-2-MOD_OFFLINE: Module 3 is offline
    I have tried gracefully removing ESXi-1 from the vDS and cluster, reformatting it with a fresh install of ESXi 5.5u1, but when I try to join it to the N1KV it throws the same error.

    Hi, 
    The SET_PORT_STATE_FAIL message is usually thrown when there is a communication issue between the VSM and the VEM while the port-channel interface is being programmed. 
    What is the uplink port profile configuration? 
    Other hosts are using this uplink port profile successfully?
    The upstream configuration on an affected and a working host is the same? (ie control VLAN allowed where necessary)
    Per kpate's post, control VLAN needs to be a system VLAN on the uplink port profile.
    The VDC SPROM message is a cosmetic defect
    https://tools.cisco.com/bugsearch/bug/CSCul65853/
    HTH,
    Joe

  • Nexus 1000v VEM module bouncing between hosts

    I'm receiving these error messages on my N1KV and don't know how to fix it.  I've tried removing, rebooting, reinstalling host B's VEM but that did not fix the issue.  How do I debug this?
    My setup,
    Two physical hosts running esxi 5.1, vcenter appliance, n1kv with two system uplinks and two uplinks for iscsi for each host.  Let me know if you need more output from logs or commands, thanks.
    N1KV# 2013 Jun 17 18:18:07 N1KV %VEM_MGR-2-VEM_MGR_DETECTED: Host 192.168.52.100 detected as module 3
    2013 Jun 17 18:18:07 N1KV %VEM_MGR-2-MOD_ONLINE: Module 3 is online
    2013 Jun 17 18:18:08 N1KV %VEM_MGR-2-VEM_MGR_REMOVE_UNEXP_NODEID_REQ: Removing VEM 3 (Unexpected Node Id Request)
    2013 Jun 17 18:18:09 N1KV %VEM_MGR-2-MOD_OFFLINE: Module 3 is offline
    2013 Jun 17 18:18:13 N1KV %VEM_MGR-2-VEM_MGR_DETECTED: Host 192.168.51.100 detected as module 3
    2013 Jun 17 18:18:13 N1KV %VEM_MGR-2-MOD_ONLINE: Module 3 is online
    2013 Jun 17 18:18:16 N1KV %VEM_MGR-2-VEM_MGR_REMOVE_UNEXP_NODEID_REQ: Removing VEM 3 (Unexpected Node Id Request)
    2013 Jun 17 18:18:17 N1KV %VEM_MGR-2-MOD_OFFLINE: Module 3 is offline
    2013 Jun 17 18:18:21 N1KV %VEM_MGR-2-VEM_MGR_DETECTED: Host 192.168.52.100 detected as module 3
    2013 Jun 17 18:18:21 N1KV %VEM_MGR-2-MOD_ONLINE: Module 3 is online
    2013 Jun 17 18:18:22 N1KV %VEM_MGR-2-VEM_MGR_REMOVE_UNEXP_NODEID_REQ: Removing VEM 3 (Unexpected Node Id Request)
    2013 Jun 17 18:18:23 N1KV %VEM_MGR-2-MOD_OFFLINE: Module 3 is offline
    2013 Jun 17 18:18:28 N1KV %VEM_MGR-2-VEM_MGR_DETECTED: Host 192.168.51.100 detected as module 3
    2013 Jun 17 18:18:29 N1KV %VEM_MGR-2-MOD_ONLINE: Module 3 is online
    2013 Jun 17 18:18:44 N1KV %PLATFORM-2-MOD_DETECT: Module 2 detected (Serial number :unavailable) Module-Type Virtual Supervisor Module Model :unavailable
    N1KV# sh module
    Mod  Ports  Module-Type                       Model               Status
    1    0      Virtual Supervisor Module         Nexus1000V          ha-standby
    2    0      Virtual Supervisor Module         Nexus1000V          active *
    3    248    Virtual Ethernet Module           NA                  ok
    Mod  Sw                  Hw     
    1    4.2(1)SV2(1.1a)     0.0                                             
    2    4.2(1)SV2(1.1a)     0.0                                             
    3    4.2(1)SV2(1.1a)     VMware ESXi 5.1.0 Releasebuild-838463 (3.1)     
    Mod  MAC-Address(es)                         Serial-Num
    1    00-19-07-6c-5a-a8 to 00-19-07-6c-62-a8  NA
    2    00-19-07-6c-5a-a8 to 00-19-07-6c-62-a8  NA
    3    02-00-0c-00-03-00 to 02-00-0c-00-03-80  NA
    Mod  Server-IP        Server-UUID                           Server-Name
    1    192.168.54.2     NA                                    NA
    2    192.168.54.2     NA                                    NA
    3    192.168.51.100   03000200-0400-0500-0006-000700080009  NA
    * this terminal session
    ~ # vemcmd show card
    Card UUID type  2: 03000200-0400-0500-0006-000700080009
    Card name:
    Switch name: N1KV
    Switch alias: DvsPortset-1
    Switch uuid: e6 dc 36 50 c0 a9 d9 a5-0b 98 fb 90 e1 fc 99 af
    Card domain: 2
    Card slot: 3
    VEM Tunnel Mode: L3 Mode
    L3 Ctrl Index: 49
    L3 Ctrl VLAN: 51
    VEM Control (AIPC) MAC: 00:02:3d:10:02:02
    VEM Packet (Inband) MAC: 00:02:3d:20:02:02
    VEM Control Agent (DPA) MAC: 00:02:3d:40:02:02
    VEM SPAN MAC: 00:02:3d:30:02:02
    Primary VSM MAC : 00:50:56:b6:0c:b2
    Primary VSM PKT MAC : 00:50:56:b6:35:3f
    Primary VSM MGMT MAC : 00:50:56:b6:d5:12
    Standby VSM CTRL MAC : 00:50:56:b6:96:f2
    Management IPv4 address: 192.168.51.100
    Management IPv6 address: 0000:0000:0000:0000:0000:0000:0000:0000
    Primary L3 Control IPv4 address: 192.168.54.2
    Secondary VSM MAC : 00:00:00:00:00:00
    Secondary L3 Control IPv4 address: 0.0.0.0
    Upgrade : Default
    Max physical ports: 32
    Max virtual ports: 216
    Card control VLAN: 1
    Card packet VLAN: 1
    Control type multicast: No
    Card Headless Mode : No
           Processors: 4
      Processor Cores: 4
    Processor Sockets: 1
      Kernel Memory:   16669760
    Port link-up delay: 5s
    Global UUFB: DISABLED
    Heartbeat Set: True
    PC LB Algo: source-mac
    Datapath portset event in progress : no
    Licensed: Yes
    ~ # vemcmd show card
    Card UUID type  2: 03000200-0400-0500-0006-000700080009
    Card name:
    Switch name: N1KV
    Switch alias: DvsPortset-0
    Switch uuid: e6 dc 36 50 c0 a9 d9 a5-0b 98 fb 90 e1 fc 99 af
    Card domain: 2
    Card slot: 3
    VEM Tunnel Mode: L3 Mode
    L3 Ctrl Index: 49
    L3 Ctrl VLAN: 52
    VEM Control (AIPC) MAC: 00:02:3d:10:02:02
    VEM Packet (Inband) MAC: 00:02:3d:20:02:02
    VEM Control Agent (DPA) MAC: 00:02:3d:40:02:02
    VEM SPAN MAC: 00:02:3d:30:02:02
    Primary VSM MAC : 00:50:56:b6:0c:b2
    Primary VSM PKT MAC : 00:50:56:b6:35:3f
    Primary VSM MGMT MAC : 00:50:56:b6:d5:12
    Standby VSM CTRL MAC : 00:50:56:b6:96:f2
    Management IPv4 address: 192.168.52.100
    Management IPv6 address: 0000:0000:0000:0000:0000:0000:0000:0000
    Primary L3 Control IPv4 address: 192.168.54.2
    Secondary VSM MAC : 00:00:00:00:00:00
    Secondary L3 Control IPv4 address: 0.0.0.0
    Upgrade : Default
    Max physical ports: 32
    Max virtual ports: 216
    Card control VLAN: 1
    Card packet VLAN: 1
    Control type multicast: No
    Card Headless Mode : Yes
           Processors: 4
      Processor Cores: 4
    Processor Sockets: 1
      Kernel Memory:   16669764
    Port link-up delay: 5s
    Global UUFB: DISABLED
    Heartbeat Set: False
    PC LB Algo: source-mac
    Datapath portset event in progress : no
    Licensed: Yes
    ! ports 1-6 connected to physical host A
    interface GigabitEthernet1/0/1
    description VMWARE ESXi Trunk
    switchport trunk encapsulation dot1q
    switchport mode trunk
    switchport nonegotiate
    spanning-tree portfast trunk
    spanning-tree bpdufilter enable
    spanning-tree bpduguard enable
    channel-group 1 mode active
    ! ports 7-12 connected to phys host B
    interface GigabitEthernet1/0/7
    description VMWARE ESXi Trunk
    switchport trunk encapsulation dot1q
    switchport mode trunk
    switchport nonegotiate
    spanning-tree portfast trunk
    spanning-tree bpdufilter enable
    spanning-tree bpduguard enable
    channel-group 2 mode active

    ok after deleteing the n1kv vms and vcenter and then reinstalling all I got the error again,
    N1KV# 2013 Jun 18 17:48:12 N1KV %VEM_MGR-2-VEM_MGR_REMOVE_STATE_CONFLICT: Removing VEM 3 due to state conflict VSM(NodeId Processed), VEM(ModIns End Rcvd)
    2013 Jun 18 17:48:13 N1KV %VEM_MGR-2-MOD_OFFLINE: Module 3 is offline
    2013 Jun 18 17:48:16 N1KV %VEM_MGR-2-VEM_MGR_DETECTED: Host 192.168.52.100 detected as module 3
    2013 Jun 18 17:48:16 N1KV %VEM_MGR-2-MOD_ONLINE: Module 3 is online
    2013 Jun 18 17:48:22 N1KV %VEM_MGR-2-VEM_MGR_REMOVE_STATE_CONFLICT: Removing VEM 3 due to state conflict VSM(NodeId Processed), VEM(ModIns End Rcvd)
    2013 Jun 18 17:48:23 N1KV %VEM_MGR-2-MOD_OFFLINE: Module 3 is offline
    2013 Jun 18 17:48:34 N1KV %VEM_MGR-2-VEM_MGR_DETECTED: Host 192.168.52.100 detected as module 3
    2013 Jun 18 17:48:34 N1KV %VEM_MGR-2-MOD_ONLINE: Module 3 is online
    2013 Jun 18 17:48:41 N1KV %VEM_MGR-2-VEM_MGR_REMOVE_STATE_CONFLICT: Removing VEM 3 due to state conflict VSM(NodeId Processed), VEM(ModIns End Rcvd)
    2013 Jun 18 17:48:42 N1KV %VEM_MGR-2-MOD_OFFLINE: Module 3 is offline
    2013 Jun 18 17:49:03 N1KV %VEM_MGR-2-VEM_MGR_DETECTED: Host 192.168.52.100 detected as module 3
    2013 Jun 18 17:49:03 N1KV %VEM_MGR-2-MOD_ONLINE: Module 3 is online
    2013 Jun 18 17:49:10 N1KV %VEM_MGR-2-VEM_MGR_REMOVE_STATE_CONFLICT: Removing VEM 3 due to state conflict VSM(NodeId Processed), VEM(ModIns End Rcvd)
    2013 Jun 18 17:49:11 N1KV %VEM_MGR-2-MOD_OFFLINE: Module 3 is offline
    2013 Jun 18 17:49:29 N1KV %VEM_MGR-2-VEM_MGR_DETECTED: Host 192.168.51.100 detected as module 3
    2013 Jun 18 17:49:29 N1KV %VEM_MGR-2-MOD_ONLINE: Module 3 is online
    2013 Jun 18 17:49:35 N1KV %VEM_MGR-2-VEM_MGR_REMOVE_STATE_CONFLICT: Removing VEM 3 due to state conflict VSM(NodeId Processed), VEM(ModIns End Rcvd)
    2013 Jun 18 17:49:36 N1KV %VEM_MGR-2-MOD_OFFLINE: Module 3 is offline
    2013 Jun 18 17:49:53 N1KV %VEM_MGR-2-VEM_MGR_DETECTED: Host 192.168.51.100 detected as module 3
    2013 Jun 18 17:49:53 N1KV %VEM_MGR-2-MOD_ONLINE: Module 3 is online
    2013 Jun 18 17:49:59 N1KV %VEM_MGR-2-VEM_MGR_REMOVE_STATE_CONFLICT: Removing VEM 3 due to state conflict VSM(NodeId Processed), VEM(ModIns End Rcvd)
    2013 Jun 18 17:50:00 N1KV %VEM_MGR-2-MOD_OFFLINE: Module 3 is offline
    2013 Jun 18 17:50:05 N1KV %VEM_MGR-2-VEM_MGR_DETECTED: Host 192.168.52.100 detected as module 3
    2013 Jun 18 17:50:05 N1KV %VEM_MGR-2-MOD_ONLINE: Module 3 is online
    Host A
    ~ # vemcmd show card
    Card UUID type  2: 03000200-0400-0500-0006-000700080009
    Card name:
    Switch name: N1KV
    Switch alias: DvsPortset-0
    Switch uuid: e6 dc 36 50 c0 a9 d9 a5-0b 98 fb 90 e1 fc 99 af
    Card domain: 2
    Card slot: 1
    VEM Tunnel Mode: L3 Mode
    L3 Ctrl Index: 49
    L3 Ctrl VLAN: 52
    VEM Control (AIPC) MAC: 00:02:3d:10:02:00
    VEM Packet (Inband) MAC: 00:02:3d:20:02:00
    VEM Control Agent (DPA) MAC: 00:02:3d:40:02:00
    VEM SPAN MAC: 00:02:3d:30:02:00
    Primary VSM MAC : 00:50:56:b6:96:f2
    Primary VSM PKT MAC : 00:50:56:b6:11:b6
    Primary VSM MGMT MAC : 00:50:56:b6:48:c6
    Standby VSM CTRL MAC : ff:ff:ff:ff:ff:ff
    Management IPv4 address: 192.168.52.100
    Management IPv6 address: 0000:0000:0000:0000:0000:0000:0000:0000
    Primary L3 Control IPv4 address: 192.168.54.2
    Secondary VSM MAC : 00:00:00:00:00:00
    Secondary L3 Control IPv4 address: 0.0.0.0
    Upgrade : Default
    Max physical ports: 32
    Max virtual ports: 216
    Card control VLAN: 1
    Card packet VLAN: 1
    Control type multicast: No
    Card Headless Mode : Yes
           Processors: 4
      Processor Cores: 4
    Processor Sockets: 1
      Kernel Memory:   16669764
    Port link-up delay: 5s
    Global UUFB: DISABLED
    Heartbeat Set: False
    PC LB Algo: source-mac
    Datapath portset event in progress : no
    Licensed: No
    Host B
    ~ # vemcmd show card
    Card UUID type  2: 03000200-0400-0500-0006-000700080009
    Card name:
    Switch name: N1KV
    Switch alias: DvsPortset-0
    Switch uuid: bf fb 28 50 1b 26 dd ae-05 bd 4e 48 2e 37 56 f3
    Card domain: 2
    Card slot: 3
    VEM Tunnel Mode: L3 Mode
    L3 Ctrl Index: 49
    L3 Ctrl VLAN: 51
    VEM Control (AIPC) MAC: 00:02:3d:10:02:02
    VEM Packet (Inband) MAC: 00:02:3d:20:02:02
    VEM Control Agent (DPA) MAC: 00:02:3d:40:02:02
    VEM SPAN MAC: 00:02:3d:30:02:02
    Primary VSM MAC : 00:50:56:a8:f5:f0
    Primary VSM PKT MAC : 00:50:56:a8:3c:62
    Primary VSM MGMT MAC : 00:50:56:a8:b4:a4
    Standby VSM CTRL MAC : 00:50:56:a8:30:d5
    Management IPv4 address: 192.168.51.100
    Management IPv6 address: 0000:0000:0000:0000:0000:0000:0000:0000
    Primary L3 Control IPv4 address: 192.168.54.2
    Secondary VSM MAC : 00:00:00:00:00:00
    Secondary L3 Control IPv4 address: 0.0.0.0
    Upgrade : Default
    Max physical ports: 32
    Max virtual ports: 216
    Card control VLAN: 1
    Card packet VLAN: 1
    Control type multicast: No
    Card Headless Mode : No
           Processors: 4
      Processor Cores: 4
    Processor Sockets: 1
      Kernel Memory:   16669760
    Port link-up delay: 5s
    Global UUFB: DISABLED
    Heartbeat Set: True
    PC LB Algo: source-mac
    Datapath portset event in progress : no
    Licensed: Yes
    I used the nexus 1000v java installer so I don't know what it keeps assigning the same UUID nor do I know how to change it.
    Here is the other output you requested,
    N1KV# show vms internal info dvs
      DVS INFO:
    DVS name: [N1KV]
          UUID: [bf fb 28 50 1b 26 dd ae-05 bd 4e 48 2e 37 56 f3]
          Description: [(null)]
          Config version: [1]
          Max ports: [8192]
          DC name: [Galaxy]
         OPQ data: size [1121], data: [data-version 1.0
    switch-domain 2
    switch-name N1KV
    cp-version 4.2(1)SV2(1.1a)
    control-vlan 1
    system-primary-mac 00:50:56:a8:f5:f0
    active-vsm packet mac 00:50:56:a8:3c:62
    active-vsm mgmt mac 00:50:56:a8:b4:a4
    standby-vsm ctrl mac 0050-56a8-30d5
    inband-vlan 1
    svs-mode L3
    l3control-ipaddr 192.168.54.2
    upgrade state 0 mac 0050-56a8-30d5 l3control-ipv4 null
    cntl-type-mcast 0
    profile dvportgroup-26 trunk 1,51-57,110
    profile dvportgroup-26 mtu 9000
    profile dvportgroup-27 access 51
    profile dvportgroup-27 mtu 1500
    profile dvportgroup-27 capability l3control
    profile dvportgroup-28 access 52
    profile dvportgroup-28 mtu 1500
    profile dvportgroup-28 capability l3control
    profile dvportgroup-29 access 53
    profile dvportgroup-29 mtu 1500
    profile dvportgroup-30 access 54
    profile dvportgroup-30 mtu 1500
    profile dvportgroup-31 access 55
    profile dvportgroup-31 mtu 1500
    profile dvportgroup-32 access 56
    profile dvportgroup-32 mtu 1500
    profile dvportgroup-34 trunk 220
    profile dvportgroup-34 mtu 9000
    profile dvportgroup-35 access 220
    profile dvportgroup-35 mtu 1500
    profile dvportgroup-35 capability iscsi-multipath
    end-version 1.0
          push_opq_data flag: [1]
    show svs neighbors
    Active Domain ID: 2
    AIPC Interface MAC: 0050-56a8-f5f0
    Inband Interface MAC: 0050-56a8-3c62
    Src MAC           Type   Domain-id    Node-id     Last learnt (Sec. ago)
    0050-56a8-30d5     VSM         2         0201      1020.45
    0002-3d40-0202     VEM         2         0302         1.33
    I cannot add Host A to the N1KV it errors out with,
    vDS operation failed on host 192.168.52.100, An error occurred during host configuration. got (vim.fault.PlatformConfigFault) exception
    Host B (192.168.51.100) was added fine, then I moved a vmkernel to the N1KV which brought up the VEM and got the VEM flapping errors.

  • VN-Link Hardware require Nexus 1000v yes or not?

    I have a problem about VN-Link Hardware. When i create port profile on UCS Manager and Create Port Profile Client then vCenter will create Port Group too. But when i apply network in Virtual Machine by select Port Group in vCenter i can't see Virtual Maching Guest in VM tab on UCS Manager.
    Finally question VN-Link Hardware require Nexus 1000v install on ESX yes or not? in UCS Manager GUI document say need require DVS Switch.

    Thank you for reply. I have successfully turn on VN-Link hardware by follow this video --> http://tinyurl.com/23p896k
    and i have install Nexus 1000v VEM in ESX for turn on VN-Link hardware.
    I need test performance of CNA Card (palo) and report to my CEO.
    - How to test it?
    - What is tool for test?
    PS.Sorry for English language

  • Cisco Nexus 1000V InterCloud

    Need download link for Cisco Nexus 1000V InterCloud

    We had a simliar issue with 5.2(1)SV3(1.3) and found this in the release notes:
    ERSPAN
    If the ERSPAN source and destination are in different subnets, and if the ERSPAN source is an L3 control VM kernel NIC attached to a Cisco Nexus 1000V VEM, you must enable proxy-ARP on the upstream switch.
    If you do not enable proxy-ARP on the upstream switch (or router, if there is no default gateway), ERSPAN packets are not sent to the destination.
    http://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus1000/sw/5_x/release_notes/b_Cisco_N1KV_VMware_521SV313_ReleaseNotes.html#concept_652D9BADC4B04C0997E7F6C29A2C8B1F
    After enabling 'ip proxy-arp' on the upstream SVI it started working properly.

  • Nexus 1000v: Control VLAN must be same VLAN as ESX hosts?

    Hello,
    I'm trying to install nexus 1000v and came across the below prerequisite.
    The below release notes for Nexus 1000v states
    VMware and Host Prerequisites
    The VSM VM control interface must be on the same Layer 2 VLAN as the ESX 4.0 host that it manages. If you configure Layer 3, then you do not have this restriction. In each case however, the two VSMs must run in the same IP subnet.
    What I'm trying to do is to create 2 VLANs - one for management and the other for control & Data (as per latest deployment guide, we can put control & data in the same vlan).
    However, I wanted to have all ESX host management same VLAN as the VSM management as well as the vCenter Management. Essentially, creating a management network.
    However, from the above "VMWare and Host Prerequisites", does this means I cannot do this?
    I need to have the ESX host management same VLAN as the control VLAN?
    This means that my ESX host will reside in a different VLAN than my management subnet?
    Thanks...

    Control vlan is a totally seperate VLAN then your System Console. The VLAN just needs to be available to the ESX host through the upstream physical switch and then make sure the VLAN is passed on the uplink port-profile that you assign the ESX host to.
    We only need an interface on the ESX host if you decide to use L3 control. In that instance you would create or use an existing VMK interface on the ESX host.

  • Nexus 1000V - Control - Packet Interfaces - vSwitch

    Hello,
    Is it possible to leave Control interface and Packet interface of my VSM on a standard vmware vswitch ?
    Same question as above for the management interface ?
    Thanks.

    Sure it is possible to leave the VSM on a vswitch if you can spare the extra physical uplinks for the vswitch.
    The VSM can reside on a server running a virtual Ethernet module (VEM), or a VMware vSwitch or DVS. If the host is running a VEM, that VEM can be managed by the VSM on the same host or a VSM on another host.
    http://www.cisco.com/en/US/docs/switches/datacenter/nexus1000/sw/4_2_1_s_v_1_4_b/install/software/guide/n1000v_install_software.html

  • If we got Nexus 1000V from VMWARE , can we add the N1K to our CCO ( Cisco Account ) to have direct support from Cisco

    Hi
    If we got Nexus 1000V from VMWARE , can we add the N1K to our CCO ( Cisco Account ) to have direct support from Cisco
    as sometimes it take some more time to get answer from VMWARE -> Cisco
    Thanks

    No.  When you purchase support from Vmware, they are your support contact and they will escalate support to Cisco on your behalf if needed.  This is the case for all OEM support.  Cisco provides support for RHEL, Microsoft and VMware.  We follow the same practice. 
    Deciding who to purchase support from is a decision of single point of contact for all VMware & N1K related issues vs. maintaining separate support contracts with each vendor individually.
    Regards,
    Robert

  • Nexus 1000v VSM can't comunicate with the VEM

    This is the configuration I have on my vsm
    !Command: show running-config
    !Time: Thu Dec 20 02:15:30 2012
    version 4.2(1)SV2(1.1)
    svs switch edition essential
    no feature telnet
    banner motd #Nexus 1000v Switch#
    ssh key rsa 2048
    ip domain-lookup
    ip host Nexus-1000v 172.16.0.69
    hostname Nexus-1000v
    errdisable recovery cause failed-port-state
    vem 3
      host vmware id 78201fe5-cc43-e211-0000-00000000000c
    vem 4
      host vmware id e51f2078-43cc-11e2-0000-000000000009
    priv 0xa2cb98ffa3f2bc53380d54d63b6752db localizedkey
    vrf context management
      ip route 0.0.0.0/0 172.16.0.1
    vlan 1-2
    port-channel load-balance ethernet source-mac
    port-profile default max-ports 32
    port-profile type ethernet Unused_Or_Quarantine_Uplink
      vmware port-group
      shutdown
      description Port-group created for Nexus1000V internal usage. Do not use.
      state enabled
    port-profile type vethernet Unused_Or_Quarantine_Veth
      vmware port-group
      shutdown
      description Port-group created for Nexus1000V internal usage. Do not use.
      state enabled
    port-profile type ethernet vmware-uplinks
      vmware port-group
      switchport mode trunk
      switchport trunk allowed vlan 1-3967,4048-4093
      channel-group auto mode on
      no shutdown
      system vlan 2
      state enabled
    port-profile type vethernet Management
      vmware port-group
      switchport mode access
      switchport access vlan 2
      no shutdown
      state enabled
    port-profile type vethernet vMotion
      vmware port-group
      switchport mode access
      switchport access vlan 2
      no shutdown
      state enabled
    port-profile type vethernet ServidoresGestion
      vmware port-group
      switchport mode access
      switchport access vlan 2
      no shutdown
      state enabled
    port-profile type vethernet L3-VSM
      capability l3control
      vmware port-group
      switchport mode access
      switchport access vlan 2
      no shutdown
      system vlan 2
      state enabled
    port-profile type vethernet VSG-Data
      vmware port-group
      switchport mode access
      switchport access vlan 2
      no shutdown
      state enabled
    port-profile type vethernet VSG-HA
      vmware port-group
      switchport mode access
      switchport access vlan 2
      no shutdown
      state enabled
    vdc Nexus-1000v id 1
      limit-resource vlan minimum 16 maximum 2049
      limit-resource monitor-session minimum 0 maximum 2
      limit-resource vrf minimum 16 maximum 8192
      limit-resource port-channel minimum 0 maximum 768
      limit-resource u4route-mem minimum 1 maximum 1
      limit-resource u6route-mem minimum 1 maximum 1
    interface mgmt0
      ip address 172.16.0.69/25
    interface control0
    line console
    boot kickstart bootflash:/nexus-1000v-kickstart.4.2.1.SV2.1.1.bin sup-1
    boot system bootflash:/nexus-1000v.4.2.1.SV2.1.1.bin sup-1
    boot kickstart bootflash:/nexus-1000v-kickstart.4.2.1.SV2.1.1.bin sup-2
    boot system bootflash:/nexus-1000v.4.2.1.SV2.1.1.bin sup-2
    svs-domain
      domain id 1
      control vlan 1
      packet vlan 1
      svs mode L3 interface mgmt0
    svs connection vcenter
      protocol vmware-vim
      remote ip address 172.16.0.66 port 80
      vmware dvs uuid "ae 31 14 50 cf b2 e7 3a-5c 48 65 0f 01 9b b5 b1" datacenter-n
    ame DTIC Datacenter
      admin user n1kUser
      max-ports 8192
      connect
    vservice global type vsg
      tcp state-checks invalid-ack
      tcp state-checks seq-past-window
      no tcp state-checks window-variation
      no bypass asa-traffic
    vnm-policy-agent
      registration-ip 172.16.0.70
      shared-secret **********
      policy-agent-image bootflash:/vnmc-vsmpa.2.0.0.38.bin
      log-level
    for some reason my vsm can't the the vem. I could before, but then my server crashed without doing a copy run start and when it booted up all my config but the uplinks was lost.
    When I tried to configure the connection again it wasn't working.
    I'm also attaching a screen capture of the vds
    and a capture of the regular switch.
    I will appreciate very much any help you could give me and will provide any configuration details that you might need.
    Thank you so much.

    Carlos,
       Looking at vds.jpg, you do not have any VEM vmkernel interface attached to port-profile L3-VSM. So fix VSM-VEM communication problem, you either migrate your VEM management vmkernel interface to L3-VSM port-profile of the vds, or create new VMkernel port on your VEM/host and attach it to L3-VSM port-profile.

  • Why can't I log into my game center account with my existing login to add my apple account?

    Why can't I log into my game center account with my existing login to add my apple account?

    Errr I'm having the same issue too, but it's my son's iPod and he's lost all his game levels, like DragonVale too He is not impressed!

  • HT5312 why can't I sign into my account and add a rescue email so I will be able to redo my security questions? I have been unable to buy anything from Itunes because it's asks me for security questions that I don't remember what I put

    why can't I sign into my account and add a rescue email so I will be able to redo my security questions? I have been unable to buy anything from Itunes because it's asks me for security questions that I don't remember what I put in the first place

    1. Because if you could, someone who breaks into your account could do it as well.
    2. You need to ask Apple to reset your security questions; ways of contacting them include clicking here and picking a method for your country, phoning AppleCare and asking for the Account Security team, and filling out and submitting this form.
    (96882)

  • Why I can't continue add photos into my iPod ???

    I don't know why I can't continue add photos into my iPod. For example, I already had some photos in my iPod and I can see the folder that contains all the photos in my iPod with a mark on it. But one think that I don't know is when I want to add more photos into my iPod, iTune will sync my iPod for a very long moment and there's no processing indication, it's like there was a message 'Syncing iPod' that show in the top of the iTune screen, but there was no 'processing bar' under it. I don't know why this happen. Do I have to erase all the photos that were currently in my iPod and the iPod Photo Cache located in My Photos to re-upload the new photos into my iPod? But in this situation, I couldn't leave the 'old photos'in my iPod. I just want to make a hudge photos library, COULD ANY GENIUS HELP ME ?

    i don't know if this will help but this is how i manage my photos:
    1. create a folder (mine is called 'ipod photos')
    2. put all the photos you want on your ipod in that folder
    3. open itunes, plug in your ipod.
    4. on the overview screen, click the photos tab
    5. check the, 'sync photos from' box.
    6. browse to the folder you want to sync with
    7. hit sync
    then when i want to add new photos, i just add them to that folder and hit sync again.

  • Which own monitors can I add into DAs

    Hi!
    I want to clear out the question on which own created monitors can I add into Distributed Applications? For example:
    I can find all monitors that I have created through Management Packs Template and add it into my DA if the monitor is from a sealed MP or in the same unsealed MP as my DA.
    I cannot add any monitors that I have created through Management Pack Objects/Monitors/Unit Monitor into any DA. Why?
    //Mats A

    Yes I understand that but for example:
    I creat one monitor Management Pack Objects/Monitors/Unit Monitor/Windows Event/Simple Event Detection/Manual Reset 
           - Name on the monitor is Approved_ID222_Event
           - Save this monitor in Approved_Monitoring
    MP
    Create one DA
           - Name on the DA is Approved
           - Save this DA in Approved_Monitoring
    MP
           - Try to find my monitor Approved_ID222_Event
    through Advanced Search. Cannot find my monitor
    //Mats A

  • HT1473 I can get my CDs into the library but my IPOD Touch will not add it.

    I can get my CDs into the library but my IPOD Touch will not add it.

    You need to convert the forma of DVDs to one compatible with the iPod. If the DVDs are commercia ones with DRM it is not legal to convert them.

  • Can a Nexus 1000v be configured to NOT do local switching in an ESX host?

    Before the big YES, use an external Nexus switch and use VN-Tag. The question is when there is a 3120 in a blade chassis that connects to the ESX hosts that have a 1000v installed on the ESX host. So, first hop outside the ESX host is not a Nexus box.
    Looking for if this is possible, if so how, and if not, where that might be documented. I have a client who's security policy prohibits switching (yes, even on the same VLAN) within a host (in this case blade server). Oh and there is an insistance to use 3120s inside the blade chassis.
    Has to be the strangest request I have had in a while.
    Any data would be GREATY appreciated!

    Thanks for the follow up.
    So by private VLANs, are you referring to "PVLAN":
    "PVLANs: PVLANs are a new feature available with the VMware vDS and the Cisco Nexus
    1000V Series. PVLANs provide a simple mechanism for isolating virtual machines in the
    same VLAN from each other. The VMware vDS implements PVLAN enforcement at the
    destination host. The Cisco Nexus 1000V Series supports a highly efficient enforcement
    mechanism that filters packets at the source rather than at the destination, helping ensure
    that no unwanted traffic traverses the physical network and so increasing the network
    bandwidth available to other virtual machines"

Maybe you are looking for

  • How do i save a picture to the camera roll from a text message in ios 7

    I am attempting to save a picture from a text message to my camera roll. However when i hold the picture the options are "copy/More" More gives the options to delete or forward via text message. And if i press copy it only copies it to be pasted. In

  • Windows Server 2012 "standard" or "datacenter" as a Deployment Server, which one??

    As the question states. I am Certified ESDT/EDA (MCITP), MCSA Windows 7, working on my Windows Server 2008 MCSA. We are hybrid, Novel/Windows environment and make our move to Windows, so my actual work with a windows environment (other then Desktop s

  • Error while fetching data from Logical data base

    Hi All, I need to fetch the data from Logical data base DDF.First when i am trying demo code REPORT demo_program_read_tables_2. NODES: spfli, sflight. GET spfli FIELDS carrid connid cityfrom cityto.   WRITE: / spfli-carrid,            spfli-connid,  

  • Get user Company Code

    Hi all, I'm new in SRM, its there a FM ot table where I can get the user company code? Thanks.

  • SERVER START BPEL HELP!

    Hello, I would like to know which server can use free to run BPEL. I am that manages, catalogs for the entire structure. Opensource which server can use to run Bpel?PLEASE Thanks