Nexus 2248TP-E Amber ports
I am looking for some feedback on an issue I am having connecting a host server to one of our nexus 2ks. L1 issue it appears.... The port I am attempting to connect to is amber in color. I connect in my server and no link. I have checked the port config, it is ready to go, the port is admin up and not disabled by any means of bpdu's, etc. I have done a shut, no shut. I have confirmed the server nic and cable are good. I noticed the fex has open ports without cables in them that are not amber, I connect in to those ports and get link immediately. Why are these ports amber and how to I take them out of this state?
Brian
Usually amber means the parent switches have not been configured correctly.
When you issue "sh fex" is the FEX on line?
HTH
Similar Messages
-
Nexus 2248TP port speed and duplexing
Hello Forum Team!
In order to configure the port speed and duplexing (change to 100Mbps/Full-duplex from auto mode) on a Nexus 2248TP interface, does the port needs to be down,.i.e, no link?
Thanks in advanced for your support!Hello and thanks for reply;
I was trying to configure port speed and duplexing on a 2148. This FEX model only works at 1000Mbps as I later found out on the documentation.
Thanks again for your support. -
NEXUS 3548 with 24 Port License
Ive a 3548 box with 24port Lic,My concern is about the functionality of the remaining 24 Ports.Will there be a problem with the rest of the 24 ports while in production.
NX3548# sh inventory
NAME: "Chassis", DESCR: "Nexus 3548 Chassis"
PID: N3K-C3548P-10G , VID: V02 , SN: XXXXXXXXXX
NAME: "Module 1", DESCR: "48x10GE Supervisor"
PID: N3K-C3548P-10G , VID: V02 , SN: XXXXXXXXXX
NX3548# SH LICense usage
Feature Ins Lic Status Expiry Date Comments
Count
24P_LIC_PKG Yes - Unused Never -
24P_UPG_PKG No - Unused -
LAN_BASE_SERVICES_PKG Yes - Unused Never -
ALGO_BOOST_SERVICES_PKG No - Unused -
LAN1K9_ENT_SERVICES_PKG No - Unused -
LAN_ENTERPRISE_SERVICES_PKG No - Unused -Hello Dhanesh,
thanks for your reply.
We have 2 3548 licensed exactly as your Nexus.
After a reboot of the two Nexus the first 4 ports (of the two) had problems (no input packets, only ouput packets, so unusable). There was connected devices with GLC-T, so they worked at 1 G, not 10G.
We opened a TAC Case about this and, after remote session and many analysis, the engineer decided to replace the two devices.
Despite this I have still some doubt.
I found the discussion below and I post some logs of one of the Nexus, we use the 10 G not in a contiguous way.
Thanks and regards
https://supportforums.cisco.com/discussion/12073821/nexus-3548-24-port-license-what-ports-use
371) Event:E_DEBUG, length:55, at 552701 usecs after Sat Mar 14 20:02:11 2015
[825307441] Couldn't send grace period data: No route to host
372) Event:E_DEBUG, length:58, at 255834 usecs after Sat Mar 14 19:02:57 2015
[825307441] Couldn't fetch grace enabled status: no such pss key
373) Event:E_DEBUG, length:55, at 819209 usecs after Sat Mar 14 19:02:18 2015
[825307441] Couldn't send grace period data: No route to host
374) Event:E_DEBUG, length:44, at 818664 usecs after Sat Mar 14 19:02:18 2015
[825307441] Failed to get VDC map: no such pss key
375) Event:E_DEBUG, length:44, at 818270 usecs after Sat Mar 14 19:02:18 2015
[825307441] Transient read error in glob_refresh()
376) Event:E_DEBUG, length:60, at 813122 usecs after Sat Mar 14 19:02:18 2015
[825307441] Expiry date for feature LAN_BASE_SERVICES_PKG: 3650000
377) Event:E_DEBUG, length:50, at 773120 usecs after Sat Mar 14 19:02:18 2015
[825307441] Expiry date for feature 24P_LIC_PKG: 3650000
378) Event:E_DEBUG, length:30, at 716563 usecs after Sat Mar 14 19:02:08 2015
[825307441] checking confcheck config
N3K-DC-1# sh int status
Port Name Status Vlan Duplex Speed Type
Eth1/1 *** FREE *** sfpAbsent 1 full 1000 --
Eth1/2 *** FREE *** sfpAbsent 1 full 1000 --
Eth1/3 *** FREE *** sfpAbsent 1 full 1000 --
Eth1/4 *** FREE *** sfpAbsent 1 full 1000 --
Eth1/5 UCS_UPLINK_FABRIC_ connected trunk full 10G SFP-H10GB-CU5M
Eth1/6 UCS_UPLINK_FABRIC_ connected trunk full 10G SFP-H10GB-CU5M
Eth1/7 -- sfpAbsent 1 full 10G --
Eth1/8 -- sfpAbsent 1 full 10G --
Eth1/9 -- sfpAbsent 1 full 10G --
Eth1/10 -- sfpAbsent 1 full 10G --
Eth1/11 -- connected trunk full 1000 1000base-T
Eth1/12 -- connected trunk full 1000 1000base-T
Eth1/13 -- sfpAbsent 1 full 10G --
Eth1/14 -- sfpAbsent 1 full 10G --
Eth1/15 -- sfpAbsent 1 full 10G --
Eth1/16 -- sfpAbsent 1 full 10G --
Eth1/17 -- sfpAbsent 1 full 10G --
Eth1/18 -- sfpAbsent 1 full 10G --
Eth1/19 -- sfpAbsent 1 full 10G --
Eth1/20 -- sfpAbsent 1 full 10G --
Eth1/21 -- sfpAbsent 1 full 10G --
Eth1/22 -- sfpAbsent 1 full 10G --
Eth1/23 -- sfpAbsent 1 full 10G --
Eth1/24 -- sfpAbsent 1 full 10G --
Eth1/25 -- sfpAbsent 1 full 10G --
Eth1/26 -- sfpAbsent 1 full 10G --
Eth1/27 -- sfpAbsent 1 full 10G --
Eth1/28 -- sfpAbsent 1 full 10G --
Eth1/29 -- sfpAbsent 1 full 10G --
Eth1/30 -- sfpAbsent 1 full 10G --
Eth1/31 *** FREE *** notconnec 1 full 1000 1000base-T
Eth1/32 -- sfpInvali 1 full 10G 1000base-T
Eth1/33 -- sfpAbsent 1 full 10G --
Eth1/34 -- sfpAbsent 1 full 10G --
Eth1/35 -- sfpAbsent 1 full 10G --
Eth1/36 -- sfpAbsent 1 full 10G --
Eth1/37 -- sfpAbsent 1 full 10G --
Eth1/38 -- sfpAbsent 1 full 10G --
Eth1/39 -- sfpAbsent 1 full 10G --
Eth1/40 -- sfpAbsent 1 full 10G --
Eth1/41 -- sfpAbsent 1 full 10G --
Eth1/42 -- sfpAbsent 1 full 10G --
Eth1/43 -- notconnec 1 full 10G 10Gbase-SR
Eth1/44 -- notconnec 1 full 10G 10Gbase-SR
Eth1/45 C3850-CORE [Port-C connected trunk full 10G 10Gbase-SR
Eth1/46 C3850-CORE [Port-C connected trunk full 10G 10Gbase-SR
Eth1/47 vPC PeerLink [Port connected trunk full 10G SFP-H10GB-CU3M
Eth1/48 vPC PeerLink [Port connected trunk full 10G SFP-H10GB-CU3M
Po2 C3850-CORE connected trunk full 10G --
Po3 3750-DC connected trunk full a-1000 --
Po4 UCS_UPLINK_FABRIC_ connected trunk full 10G --
Po10 vPC PeerLink connected trunk full 10G --
mgmt0 -- connected routed full a-1000 -- -
Nexus 5500 - Fabricpath Core Port - Error disabled. Reason:DCX-No ACK in 100 PDUs
Has anyone seen Fabricpath Core Interfaces between two Nexus 5596UP switches error-disabled because of missing DCBX Acks after 50mins?
I do not see interface errors and the peer is another 5500.
Both switches are running 5.1(3)N2(1) with this port config:
int e1/3
switchport mode fabricpath
! Cisco 5m Twinax cables
Log messages
2012 May 25 17:40:59 nexus1 %L3VM-5-FP_TPG_INTF_DOWN: Interface Ethernet1/3 down in fabricpath topology 0 - Interface down
2012 May 25 17:40:59 nexus1 %ETHPORT-5-IF_DOWN_NONE: Interface Ethernet1/3 is down (None)
2012 May 25 17:40:59 nexus1 %ISIS_FABRICPATH-5-ADJCHANGE: isis_fabricpath-default [3365] P2P adj L1 nexus5 over Ethernet1/3 - DOWN (Delete All) on MT-0
2012 May 25 17:40:59 nexus1 %CDP-5-NEIGHBOR_REMOVED: CDP Neighbor nexus5(FOX1550GDH1) on port Ethernet1/3 has been removed
2012 May 25 17:40:59 nexus1 %LLDP-5-SERVER_REMOVED: Server with Chassis ID 547f.ee63.fa88 Port ID Eth1/1 on local port Eth1/3 has been removed
2012 May 25 17:40:59 nexus1 %ETHPORT-2-IF_DOWN_ERROR_DISABLED: Interface Ethernet1/3 is down (Error disabled. Reason:DCX-No ACK in 100 PDUs)
RobertCan you send the output of
show lldp interface ethernet 1/3
show lldp dcbx interface ethernet 1/3
a workaround may be to disable lldp on both sides on these physical interfaces -
Nexus 7000 Supervisor Management Port
Hi,
I have a deployment with 2 x Nexus 7009. Both N7K's have dual supervisor modules.
Each Supervisor Module is connected to alternate management switches.
Supervisor 1 is connected to Management Switch 1
Supervisor 2 is connected to Management Switch 2
In the event of a failure of Management Switch 1, access to Supervisor 1 is lost and in turn all access to the N7K.
Is there any method of achieving connectivity to the Active Supervisor (1) when this scenario occurs.Can connectivity be achieved via the Standby Supervisor (other than making the Standby Supervisor the Active Supervisor).
Thanks,
ColmThat is the correct behavior. As long as the primary sup is up, you will see the mgmt0 for the primary Sup up. The second you fail over to the stand-by sup, the mgmt0 for that sup will come up and the old primary will go down. So, it is only one mgmt0 is up at a time.
Make sure both mgmt0 interfaces are in the same vlan and also port fast is turned on so the mgmt ports comes up as soon as possible.
HTH -
2950 Catalyst - what do green to amber ports mean?
Occatioanl our grren ports flicker to amber, what does this mean?
You could have a problem but not necessarily. The first thing to do is check the port to see if it is running in half duplex. I have seen router attached ports at half duplex ocassionally flash amber due to the number of collisions during heavy traffic. That is not really a problem, but collisions can get excessive if the traffic is too high. If the link is actually dropping you have a cable fault. I have seen people try to use old cat3 patch cables and that will cause the light to turn amber, but the link is actually bouncing. You can check the logs for that.
Like someone else said, you could have a duplex mismatch, but you should be able to verify the duplex settings on both sides easy enough.
R Duke -
Nexus 6004: Question about port-profile type port-channel
I'm setting up a new deployment of Nexus 6004 switches and want to utilize port-profiles as much as possible to simplify management down the road.
All uplinks to other switches, routers and firewalls will be connected using VPC:s. On the port-channels (vpc) the only thing that will change over time is the allowed vlans.
It seems that port-profiles of the type port-channel does not behave in the same way as those with type ethernet, at least not when adding vlans.
If I modify the port-profile using "switchport trunk allowed vlan add XXX" it will delete the previous config and only retain "switchport trunk allowed vlan add XXX", and not merge it with the previous config as is expected.
Question: Is this a bug or is it working as intended?
RH_N6K4_01(config-sync)# switch-profile rh
Switch-Profile started, Profile ID is 1
RH_N6K4_01(config-sync-sp)# port-profile type port-channel FIREWALL-UPLINK
RH_N6K4_01(config-sync-port-prof)# switchport trunk allowed vlan 3
RH_N6K4_01(config-sync-port-prof)# verify
Verification Successful
RH_N6K4_01(config-sync-sp)# commit
Verification successful...
Proceeding to apply configuration. This might take a while depending on amount of configuration in buffer.
Please avoid other configuration changes during this time.
Commit Successful
RH_N6K4_01(config-sync)# show port-profile
SHOW PORT_PROFILE
port-profile FIREWALL-UPLINK
type: Port-channel
description:
status: enabled
max-ports: 512
inherit:
config attributes:
switchport mode trunk
switchport trunk allowed vlan 3
evaluated config attributes:
switchport mode trunk
switchport trunk allowed vlan 3
assigned interfaces:
===================================
RH_N6K4_01(config-sync-sp)# port-profile type port-channel FIREWALL-UPLINK
RH_N6K4_01(config-sync-port-prof)# switchport trunk allowed vlan add 84
RH_N6K4_01(config-sync-port-prof)# verify
Verification Successful
RH_N6K4_01(config-sync-sp)# commit
Verification successful...
Proceeding to apply configuration. This might take a while depending on amount of configuration in buffer.
Please avoid other configuration changes during this time.
Commit Successful
RH_N6K4_01(config-sync)# show port-profile
SHOW PORT_PROFILE
port-profile FIREWALL-UPLINK
type: Port-channel
description:
status: enabled
max-ports: 512
inherit:
config attributes:
switchport mode trunk
switchport trunk allowed vlan add 84
evaluated config attributes:
switchport mode trunk
switchport trunk allowed vlan add 84
assigned interfaces:
Expected behavior here would be "switchport trunk allowed vlan 3,84". This only occurs when using "port-profile type port-channel" not when using "port-profile type ethernet"<> is template syntax and is generally the type of object a container holds.. So it is defining that the MSGQUEUE type is a deque holding struct_buffer*'s.
-
Nexus 2232 TM uplink ports are they only for uplink use?
We have upgraded our N5K to support the new 2232TM, but now we face the issue that the 8 SFP+ ports are not visible in our config:
Nexus5010_1# sh fex 103 det
FEX: 103 Description: 2KSRV02 state: Online
FEX version: 5.0(3)N2(2a) [Switch version: 5.0(3)N2(2a)]
FEX Interim version: 5.0(3)N2(2a)
Switch Interim version: 5.0(3)N2(2a)
Extender Model: N2K-C2232TM-10GE, Extender Serial: FOC15262P7Q
Part No: 73-13626-03
Card Id: 164, Mac Addr: 30:e4:db:66:12:02, Num Macs: 64
Module Sw Gen: 21 [Switch Sw Gen: 21]
post level: complete
pinning-mode: static Max-links: 1
Fabric port for control traffic: Eth1/9
Fabric interface state:
Po103 - Interface Up. State: Active
Eth1/9 - Interface Up. State: Active
Eth1/10 - Interface Up. State: Active
Fex Port State Fabric Port
Eth103/1/1 Down Po103
Eth103/1/2 Down Po103
Eth103/1/3 Down Po103
Eth103/1/4 Down Po103
Eth103/1/5 Down Po103
Eth103/1/6 Down Po103
Eth103/1/7 Down Po103
Eth103/1/8 Down Po103
Eth103/1/9 Down Po103
Eth103/1/10 Down Po103
Eth103/1/11 Down Po103
Eth103/1/12 Down Po103
Eth103/1/13 Down Po103
Eth103/1/14 Down Po103
Eth103/1/15 Down Po103
Eth103/1/16 Down Po103
Eth103/1/17 Down Po103
Eth103/1/18 Down Po103
Eth103/1/19 Down Po103
Eth103/1/20 Down Po103
Eth103/1/21 Down Po103
Eth103/1/22 Down Po103
Eth103/1/23 Down Po103
Eth103/1/24 Down Po103
Eth103/1/25 Down Po103
Eth103/1/26 Down Po103
Eth103/1/27 Down Po103
Eth103/1/28 Down Po103
Eth103/1/29 Down Po103
Eth103/1/30 Down Po103
Eth103/1/31 Down Po103
Eth103/1/32 Down Po103
They are not visible: neither with the "show fex" neither with the "show int status", we cannot configure them....?
Do you think it's possible to access these ports by another way and configure them to allow some hosts to connect on it or is their purpose exclusively UPLINK?
best regards,
Eric GillisDo you mean the Fabric interfaces? If yes, you cannot use those for any host connectivities.
HTH,
jerry -
Nexus 7K Supervisor Management Port
Hello Everyone,
Any help would be greatly appreciated. Scenario: Currently managing 7K through the active* supervisor's management interface via the defualt VRF (management). In the case of a failover, how would one configure the second supervisor, the one in "ha-standgy"? Would the configuration be copied over to that interface and would just need to provide another link to the OBN switch? Thanks again.As this post is now a couple of days ago you may have already discovered the answer. However, the vPC requires a unique Port-Channel group for each downstream device between the vPC peer devices, the two N7Ks in this case. Essentially you need to configure three port-channels, one for each of your downstream N5Ks on both your N7K vPC peer devices:-
For example:-
N7K-1
interface ethernet 7/1-2
description to N5k-1
switchport mode trunk
switchport trunk allowed vlan 1-50
channel-group 100 mode active
interface port-channel 100
vpc 100
N7K-2
interface ethernet 7/1-2
description to N5k-1
switchport mode trunk
switchport trunk allowed vlan 1-50
channel-group 100 mode active
interface port-channel 100
vpc 100
N7K-1
interface ethernet 7/9-10
description to N5k-2
switchport mode trunk
switchport trunk allowed vlan 1-50
channel-group 101 mode active
interface port-channel 101
vpc 101
N7K-2
interface ethernet 7/9-10
description to N5k-2
switchport mode trunk
switchport trunk allowed vlan 1-50
channel-group 101 mode active
interface port-channel 101
vpc 101
etc.
Hope this helps
Allan. -
Nexus M1 Series 32 port 10G Module Local Switching Support ?
Hi,
Ive got d 32 port M1 series linecard asic architecture slide below.
There seems to be a local fabric asic on this M1 series card. Anyone knows whether if this module supports local switching and what is the capacity of local switching ?
We are all aware that this module sits 80G on the chassis fabric modules.
Thanks.4:1 mux is downstream from replication ASIC which has total 10Gb toward each front panel port-group. So correct you can never put more than 10Gbit/s in/out combined across the ports in one port-group.
As an example say ports 1,3,5,7 each receive 10Gbit/s unicast for ports 9,11,13,15 (1->9, 3->11, ..) The port-group only has 10Gbit/s upwards so incoming excess is dropped at mux and depending on packet ordering you'd get around 2.5Gbit/s out on each port 9,11,13,15.
This is why the module has an 80Gb fabric connection, as there is only 80Gb from replication down to front-panel ports the fabric ASIC will never see more than 80Gbit/s so doesn't need any more channels.
Cheers,
/Phil -
All models of the nexus 2000 has HDMI port
Installation guide says it is for console connectivity. There was no special cable supplied with Nexus 2000.
anyone tried to use that port? I want to what type of cable connector to use to console in to the FEX. Anyone knows what type of cable to use??
I know FEX can be consoled in using attach fex 101 command on parent switch but then what is purpose of this HDMI port.Krunal,
It is not an HDMI port, though it kind of resembles one. This port is utility port used by manfucaturing & TAC. As the N2K is managed by the N5K which has your traditional console port, it's not necessary for console access direclty to the FEX. It's stictly for diagnositcs. These ports are standard on FEXs including the IO Modules within a UCS Chassis.
These cables are not supplied to customer or available for purchase.
Regards,
Robert -
Is there really any true need for port-security on Nexus 1000v for vethernet ports? Can a VM be assigned a previously used vethernet port that would trigger a port-security action?
If you want to prevent admins or malicious users from being able change the mac address of a VM then port-security is a useful feature. Especially in VDI environments where users might have full admin control of the VM and can change the mac of the vnic.
Now about veths ports. A veth gets assigned to a VM and stays with that VM. A veth is only released when either the nic on the VM is deleted or the nic is assigned to another port-profile on the N1KV or a port-group on a vSwitch or VMware DVS. Now when the veth is released it does not retain any of the piror information. It's freed up and added to a pool of available veths. When a veth is needed for a VM in either the same port-profile or a different port-profile the free veth will be grabbed and initialized. It does not retain any of the previous settings.
So assigning a VM to a previsously used veth port should not trigger a violation. The MAC should get learned and traffic should be able to flow. -
Single Nexus 5548UP- FCoE configuration with multiple server ports
Hello Everyone,
I am new to Networking so please bear with me.
Here is some background information. We have a SINGLE Nexus 5548 UP switch to which we are connecting both the storage and the UCS C240 M3 servers (with CNA). Both the storage and server has 2 ports each going to this nexus switch.
We want to implement FCoE with this solution.
Below are the steps (for server ports) that I have followed to configure the nexus. But the port not logging into the SAN (no flogi) with the config.
Enable Features
config t
feature lacp
feature dot1x
feature interface-vlan
feature sshServer
feature npiv
end
Confgure Ethernet Ports - Server
configure
interface ethernet 1/17
description To_UCS_rack_server_1_FCoE_port_1
switchport mode trunk
switchport trunk native vlan 6
switchport trunk allowed vlan 1,6
spanning-tree port type edge trunk
priority-flow-control mode on
no shutdown
end
configure
interface ethernet 1/18
description To_UCS_rack_server_1_FCoE_port_2
switchport mode trunk
switchport trunk native vlan 6
switchport trunk allowed vlan 1,6
spanning-tree port type edge trunk
priority-flow-control mode on
no shutdown
end
Create VLAN
configure
vlan 6
name FCOE_VLAN
fcoe vsan 6
end
Setup FCoE QOS
configure terminal
system qos
service-policy type qos input fcoe-default-in-policy
service-policy type queuing input fcoe-default-in-policy
service-policy type queuing output fcoe-default-out-policy
service-policy type network-qos fcoe-default-nq-policy
end
Create vfc for Initiators (UCS Servers)
configure
interface vfc 17
bind interface ethernet 1/17
switchport description virtual_fiber_channel_Server1_Port1
end
configure
interface vfc 18
bind interface ethernet 1/18
switchport description virtual_fiber_channel_Server1_Port2
end
Adding vFC’s to VSAN
configure
vsan database
vsan 6 interface vfc 17
vsan 6 interface vfc 18
Create Zonesets and Zones
configure
show flogi database vsan 6 ----> Do not see any pwwn here???
show fcns database vsan 6
Any help in the regard would be highly appreciated.
Cheers,
KSFixed the issue. "switchport trunk native vlan 6" was causing the issue. Maybe the storage and Servers were not configured with proper VLAN's. I removed the native vlan and everything logged in fine.
Any how I have configured a single zone with all 3 servers pWWN's. I know single initiator zoning is the way to go.
Can you please guide me if I can move these servers in their separate zones without any outages? If it helps, all severs have 2 pWWN's. The current zoneset is active with that single zone.
Please let me know if you need any additional details.
Cheers,
KS -
ISE 3355 Appliance use of both GigE ports
I am setting up six ISE 3355 appliances 3 in one datacenter 3 in another. They have just installed a new server farm infrastructure using Nexus 5596 and Nexus 2248TP top of rack switches.
I have been looking for documentation on how to do NIC teaming on the 3355 or some way to connect Gig0 to FEX101 and Gig1 to FEX102. Or do I just setup a port channel using LaCP between the two different FEX groups?
Sent from Cisco Technical Support iPhone AppHi,
This is not supported, you can not team or load balance or use redundant interfaces on the ISE appliances. You can only use a dedicated span port for ISE deployments, or use crossover links for an ipep deployment in HA mode.
thanks,
Tarik Admani
*Please rate helpful posts* -
The setup on the Nexus tablet asks for port numbers for both incoming and outgoing mail, but the email setup on the ipad does not ask for port numbers. Am I supposed to be inputting the port numbers by inserting them after a colon followed by the port numbers in both the incoming and outgoing mail server fields or is there something else I am doing wrong?
Hey Garlicdaisy,
Thank you for the follow up.
With iCloud, you can have iTunes automatically download new music purchases to all your devices the moment you tap Buy. You can also access past music, movie, and TV show purchases from any of your devices — wirelessly and without syncing.
For more information, see the following:
Apple - iCloud - All your music on all your devices.
http://www.apple.com/icloud/features/itunes-in-the-cloud/
To download past purchases on your devices, follow these steps:
Downloading past purchases from the App Store, iBookstore, and iTunes Store
http://support.apple.com/kb/HT2519
If you want the benefits of iTunes in the Cloud for music you haven’t purchased from iTunes, iTunes Match is the perfect solution:
Apple - iTunes - Match
http://www.apple.com/itunes/itunes-match/
Thanks,
Matt M.
Maybe you are looking for
-
Hi all, and a big hello from a beginner in this forum! I'm going to download new drivers for my old Audigy Platinum (200), the file name is: sabx_webup_lb_2_08_0004. My question is: does it works good? One year ago I downloaded a driver from this sit
-
The primary, horizontal monitor is connected by the VGA-MiniDisplay adapter, and the secondary monitor (vertical) is connected with a VGA-USB adapter. They both connect fine, but I only have the option to rotate both at once. That is, the main 'Syste
-
Using Oracle OCI Driver 8.1.6 in Compaq Tru64 fastVM
Hi! I try to using Oracle OCI Driver in Compaq Tru64. I used fast VM (with -fast option weblogic startup) then the result during populating Connection Pool, weblogic server down with core dump I attached core file. is there anyone in this situation?
-
Create table as with append hint
All, This is part of my oracle plsql procedure. EXECUTE IMMEDIATE 'create table inventory_stg TABLESPACE users PARALLEL 6 AS SELECT DISTINCT /*+ parallel(stg,6) */ orders.order_sid, ORDERS.order_doc, stg.ref_doc_num quote_num FROM stg, ORDERS, QUOTE
-
Does the Pop-Up Menu causes the Video a small jump to the closest Pop-Up chapter?
I have setted five Pop-up Chapter Menu for my project but after burning the blu ray, I have notice the vidoe coming close to one of the Pop-up Chapter will a small jump to the pop-up point. It happens to all of the Pop-Up chapter. Is there a way to m