Nexus 5010 vlan supported limits

Hi,
Just wanted to know whether the configuration  limits of 512 vlan on Nexus 5010 specified in the document below are software limitation which can be removed by adding enhanced image etc or hard limits which cannot be removed.
http://www.cisco.com/en/US/docs/switches/datacenter/nexus5000/sw/configuration_limits/limits_503/nexus_5000_config_limits_503_n1_1b.html
Regards
Vijay Sequeira

Hard limits. There is no special license that can increase the numbers. Nexus doesnt have the concept of enhanced images either there is a single OS image and you just unlock specific features (eg fibre channel/fcoe  features) by applying licences.

Similar Messages

  • Private Vlan, Etherchannel and Isolated Trunk on Nexus 5010

    I'm not sure if I'm missing something basic here however i though that I'd ask the question. I recieved a request from a client who is trying to seperate traffic out of a IBM P780 - one set of VIO servers/clients (Prod) is tagged with vlan x going out LAG 1 and another set of VIO server/clients (Test) is tagged with vlan y and z going out LAG 2. The problem is that the management subnet for these devices is on one subnet.
    The infrastructure is the host device is trunked via LACP etherchannel to Nexus 2148TP(5010) which than connects to the distribution layer being a Catalyst 6504 VSS. I have tried many things today, however I feel that the correct solution to get this working is to use an Isolated trunk (as the host device does not have private vlan functionality) even though there is no requirement for hosts to be segregated. I have configured:
    1. Private vlan mapping on the SVI;
    2. Primary vlan and association, and isolated vlan on Distribution (6504 VSS) and Access Layer (5010/2148)
    3. All Vlans are trunked between switches
    4. Private vlan isolated trunk and host mappings on the port-channel interface to the host (P780).
    I haven't had any luck. What I am seeing is as soon as I configure the Primary vlan on the Nexus 5010 (v5.2) (vlan y | private-vlan primary), this vlan (y) does not forward on any trunk on the Nexus 5010 switch, even without any other private vlan configuration. I believe this may be the cause to most of the issues I am having. Has any one else experienced this behaviour. Also, I haven't had a lot of experience with Private Vlans so I might be missing some fundamentals with this configuration. Any help would be appreciated.

    Hello Emcmanamy, Bruce,
    Thanks for your feedback.
    Just like you, I have been facing the same problematic last months with my customer.
    Regarding PVLAN on FEX, and as concluded in Bruce’s previous posts I understand :
    You can configure a host interface as an isolated or community access port only.
    We can configure “isolated trunk port” as well on a host interface. Maybe this specific point could be updated in the documentation.  
    This ability is documented here =>
    http://www.cisco.com/en/US/docs/switches/datacenter/nexus5000/sw/layer2/513_N2_1/b_Cisco_n5k_layer2_config_gd_rel_513_N2_1_chapter_0101.html#task_1170903
    You cannot configure a host interface as a promiscuous  port.
    You cannot configure a host interface as a private  VLAN trunk port.
    Indeed a pvlan is not allowed on a trunk defined on a FEX host interface.
    However since NxOS 5.1(3)N2(1), the feature 'PVLAN on FEX trunk' is supported. But a command has to be activated before => system private-vlan fex trunk . When entered a warning about the presence of ‘FEX isolated trunks’ is prompted.
    http://www.cisco.com/en/US/docs/switches/datacenter/nexus5000/sw/layer2/513_N2_1/b_Cisco_n5k_layer2_config_gd_rel_513_N2_1_chapter_0101.html#task_16C0869F1B0C4A68AFC3452721909705
    All these conditions are not met on a N5K interface.
    Best regards.
    Karim

  • Nexus (5010) To FEX Distance Limitations

    Hello,
    My question is concerning the software-imposed distance limitations for Nexus-to-Fex connections.
    With a Nexus 5010 running 4.2 (1) N1 (1) code, I believe there is a software limitation on the distance the FEX can be located from the Nexus.  I have two questions concerning this:
    Is there any log data, or a cli command, to verify that the fex connection has exceeded that distance?
    What symptoms are produced when the fex is too far from the Nexus (ie, does the link come up but the image not load?)
    I would like to determine that the reason I have a FEX, located in a second data centre, that is not coming up is actually related to the distance from the FEX to the Nexus and not related to some other problem.
    Thanks for any suggestions/info offerred.
    Simon

    I have not seen any reference to a software limitation for the distance between a N5K and a FEX.
    The release notesfor 4.2(1)N1) listed si not showing it unless, my first cup of coffee has not kicked in
    http://http://www.cisco.com/en/US/partner/docs/switches/datacenter/nexus5000/sw/configuration_limits/limits_421/Cisco_Nexus_5000_Series_Configuration_Limits_for_Cisco_NX_OS_Release_421_N1_1_and_421_N2_1_chapter1.html
    As far as believe the only distance limitation would be the type of cable used. Either the distance limitation of the SMF SFP or the MMF SFP, or the CX ethernet cable which has reletively short distance spans.
    Where is you here about this limitation?
    And more importantly, what issues are you have towards the FEX?

  • Can't archive nexus 5010 configs (LMS 3.2)

    Using LMS 3.2 I can't archive configs from
    our Nexus 5010 ( 4.2(1)N1(1) ) devices . I have installed
    the   necessary device package Nexus.RME431.v2-4.zip. Following error occures:
    *** Device Details for                          gf02na50050p                         ***
    Protocol ==>                          Unknown / Not Applicable
    Selected Protocols with order ==>                                                                                  SSH,SCP,TFTP,RCP,Telnet
    Execution Result:
    RUNNING
    CM0151 PRIMARY RUNNING Config  fetch failed for gf02na50050p Cause: Failed to fetch config using  TFTPFailed to establish TELNET connection to 10.92.170.214 - Cause:  Connection refused.
    Action: Check if protocol is  supported by device and required device package is installed. Check  device credentials. Increase timeout value, if required.
    Telnet on device is disabled, SSH enabled.
    with only SSH on RME   followig error:
    *** Device Details for                          gf02na50050p                         ***
    Protocol ==>                          Unknown / Not Applicable
    Selected Protocols with order ==>                                                                                  SSH
    Execution Result:
    RUNNING
    CM0151 PRIMARY RUNNING Config  fetch failed for gf02na50050p Cause: Failed to get the start  tag-Building Configuration ... in the configuration.  Action: Check if  protocol is supported by device and required device package is  installed. Check device credentials. Increase timeout value, if  required.
    Thanks
    Igor

    RME 4.3.1; windows platform
    with one customer I have the same issue with a Nexus 5020. Software version is :
    Software
      BIOS:      version 1.3.0 [last: ]
      loader:    version N/A
      kickstart: version 4.2(1)N2(1)
      system:    version 4.2(1)N2(1)
      power-seq: version v1.2
      BIOS compile time:       09/08/09 [last: ]
      kickstart image file is: bootflash:///n5000-uk9-kickstart.4.2.1.N2.1.bin
      kickstart compile time:  7/28/2010 18:00:00 [07/29/2010 03:10:19]
      system image file is:    bootflash:/n5000-uk9.4.2.1.N2.1.bin
      system compile time:     7/28/2010 18:00:00 [07/29/2010 07:18:12]
    Hardware
      cisco Nexus5020 Chassis ("40x10GE/Supervisor")
      Intel(R) Celeron(R) M CPU    with 2074284 kB of memory.
    ===============
    following RME packages are installed:
        SharedNetshowSS      1.1.2      SharedNetshowSS device package
        SharedSwimMDS9000    1.6.3      SharedSwimMDS9000 device package
        SharedInventoryMDS   1.5.1      SharedInventoryMDS device package
        SharedDcmaSS         2.2.2      SharedDcmaSS device package
        Nexus                2.4        Nexus device package
    ===============
    >>> I see the following problems with SSH instrumentation of the Nexus Platform when looking into the debug file. The file I got is more or less the same then the one Marc posted.
    The customer does not have a banner configured so the standard login procedure shows the following when login is done manually. RME automatically interpretes the first line after "Login as: " as a banner...
    login as: Nexus
    Nexus 5000 Switch
    Using keyboard-interactive authentication.
    Password:
    Cisco Nexus Operating System (NX-OS) Software
    TAC support: http://www.cisco.com/tac
    Copyright (c) 2002-2010, Cisco Systems, Inc. All rights reserved.
    The copyrights to certain works contained in this software are
    owned by other third parties and used and distributed under
    license. Certain components of this software are licensed under
    the GNU General Public License (GPL) version 2.0 or the GNU
    Lesser General Public License (LGPL) Version 2.1. A copy of each
    such license is available at
    http://www.opensource.org/licenses/gpl-2.0.php and
    http://www.opensource.org/licenses/lgpl-2.1.php
    devicename#
    >>> and RME wants to take the last line as the prompt, resulting in a non-fatal java exception:
    [line 1471 ff.]
    [ Mon Aug 30  08:58:01 CEST 2010 ],DEBUG,[Thread-38],com.cisco.nm.xms.xdi.transport.cmdsvc.LogAdapter,debug,31,Learning prompt: sA[0] == 'http://www.opensource.org/licenses/lgpl-2.1.php'
    [ Mon Aug 30  08:58:01 CEST 2010 ],DEBUG,[Thread-38],com.cisco.nm.xms.xdi.transport.cmdsvc.LogAdapter,debug,31,Learning prompt: sA[1] == ''
    [ Mon Aug 30  08:58:01 CEST 2010 ],DEBUG,[Thread-38],com.cisco.nm.xms.xdi.transport.cmdsvc.LogAdapter,printStackTrace,51,stacktracecom.cisco.nm.lib.cmdsvc.CmdSvcException: Prompt learning failed: 'http://www.opensource.org/licenses/lgpl-2.1.php' && '' do not match.
        at com.cisco.nm.lib.cmdsvc.Session.tune(Session.java:904)
        at com.cisco.nm.lib.cmdsvc.Session.tune(Session.java:833)
        at com.cisco.nm.lib.cmdsvc.AuthHandler.connect(AuthHandler.java:267)
        at com.cisco.nm.lib.cmdsvc.OpConnect.invoke(OpConnect.java:56)
        at com.cisco.nm.lib.cmdsvc.SessionContext.invoke(SessionContext.java:299)
    >> Ok, RME proceeds, but the SSH implementation (SharedDcmaSS ?) cannot extract the config and a java exception occures which leads to "Closing the session":
    [ Mon Aug 30  08:58:06 CEST 2010 ],DEBUG,[Thread-38],com.cisco.nm.xms.xdi.transport.cmdsvc.LogAdapter,debug,31,Returning from Session.send('show startup-config
    [ Mon Aug 30  08:58:06 CEST 2010 ],DEBUG,[Thread-38],com.cisco.nm.xms.xdi.transport.cmdsvc.LogAdapter,debug,31,in trimPrompt(), prompt == ''
    [ Mon Aug 30  08:58:06 CEST 2010 ],DEBUG,[Thread-38],com.cisco.nm.xms.xdi.pkgs.LibDcma.persistor.CliOperator,fetchConfig,490,Failed to get the start tag-Building Configuration ... in the configuration.com.cisco.nm.xms.xdi.ags.config.ConfigTransportException: Failed to get the start tag-Building Configuration ... in the configuration.
        at com.cisco.nm.xms.xdi.pkgs.SharedDcmaSS.transport.SSCliOperator.extractConfig2Buffer(SSCliOperator.java:176)
        at com.cisco.nm.xms.xdi.pkgs.LibDcma.persistor.CliOperator.fetchConfig(CliOperator.java:436)
        at com.cisco.nm.xms.xdi.pkgs.LibDcma.persistor.CliOperator.fetchConfig(CliOperator.java:510)
        at com.cisco.nm.xms.xdi.pkgs.LibDcma.persistor.SimpleFetchOperation.performOperation(SimpleFetchOperation.java:61)
        at com.cisco.nm.xms.xdi.pkgs.LibDcma.persistor.ConfigOperation.doConfigOperation(ConfigOperation.java:111)
        at com.cisco.nm.xms.xdi.pkgs.SharedDcmaSS.transport.SSConfigOperator.fetchConfig(SSConfigOperator.java:65)
        at com.cisco.nm.rmeng.dcma.configmanager.ConfigManager.updateArchiveForDevice(ConfigManager.java:1315)
        at com.cisco.nm.rmeng.dcma.configmanager.ConfigManager.performCollection(ConfigManager.java:3291)
        at com.cisco.nm.rmeng.dcma.configmanager.CfgUpdateThread.run(CfgUpdateThread.java:27)
    [ Mon Aug 30  08:58:06 CEST 2010 ],DEBUG,[Thread-38],com.cisco.nm.xms.xdi.pkgs.LibDcma.persistor.SimpleFetchOperation,performOperation,62,FetchStatus - FAILURE for Protocol SSH for device x.x.x.x
    >> As telnet and tftp are not allowed the config cannot be archived (Customer reports no problems with telnet...)
    The config itself starts and ends with the following lines:
    devicename# show startup-config
    !Command: show startup-config
    !Time: Mon Sep  6 16:41:02 2010
    !Startup config saved at: Mon Aug 16 15:41:39 2010
    version 4.2(1)N2(1)
    no feature telnet
    no telnet server enable
    no feature http-server
    cfs eth distribute
    feature udld
    feature interface-vlan
    feature lacp
    feature vpc
    feature lldp
    feature vtp
    interface mgmt0
      shutdown force
      shutdown force
      no snmp trap link-status
      no snmp trap link-status
    clock timezone MEZ 1 0
    clock summer-time MEZS 5 sun mar 02:00 5 sun oct 03:00 60
    line console
    boot kickstart bootflash:/n5000-uk9-kickstart.4.2.1.N2.1.bin
    boot system bootflash:/n5000-uk9.4.2.1.N2.1.bin
    ip route 0.0.0.0/0 172.16.4.1
    vtp mode transparent
    vtp domain sap
    logging server x.x.x.x 7 use-vrf default
    logging server y.y.y.y 7 use-vrf default
    devicename#
    For me it looks like as a bug in the ssh implementation in RME, but I cannot find a bug id on CCO ....

  • Nexus 5010 to Cat 6506 Sup720 using 1GB ports

    Hi,
    Our budget just got cut in half--sign of the times! Can I connect a Nexus 5010 to a 6506 with 6724-SFP module using a 6GB etherchannel? The 6506 has a Sup 720 and will only be used to route the VLANs. All server swithing will be done through the Nexus 5010 and 2148T.
    Thanks,

    hi Isabel,
    >> Jul 5, 2009, 9:14am PST
    >> Both the Nexus 5000 and Nexus 7000 will add support for a
    >> feature called Virtual Port Channels (VPC) which allows
    >> the formation of multi-chassis ether channels like that
    >> with VSS on the Catalyst 6500.
    Nexus 7000 has had virtual Port Channel (vPC) since the release of NX-OS 4.2 around January this year.
    see http://www.cisco.com/en/US/prod/collateral/switches/ps9441/ps9402/white_paper_c11-516396.html
    you are correct that Nexus 5000 doesn't yet have this. N5K will gain vPC when NX-OS 4.2 is released on N5K in/on/around Q3 CY2009.
    cheers,
    lincoln.

  • Fex 1 Nexus 2148 to 2 Nexus 5010 problem?

    hi all
    I'm having trouble when fex(ing) 1 nexus 2000 to 2 nexus 5000.
    I've configured as dual home from 1 nexus 2k. But after success config, just 1 nexus 5k can see 48 port on it. other cannot see it and it showed as module offline
    Here's is results:
    N5K-01(config-if)# sh int e1/4 fex-intf
    Fabric           FEX
    Interface        Interfaces
    Eth1/4        
    N5K-01(config-if)#
    N5K-02# sh int e1/4 fex-intf
    Fabric           FEX
    Interface        Interfaces
    Eth1/4          Eth100/1/48   Eth100/1/47   Eth100/1/46   Eth100/1/45 
                     Eth100/1/44   Eth100/1/43   Eth100/1/42   Eth100/1/41 
                     Eth100/1/40   Eth100/1/39   Eth100/1/38   Eth100/1/37 
                     Eth100/1/36   Eth100/1/35   Eth100/1/34   Eth100/1/33 
                     Eth100/1/32   Eth100/1/31   Eth100/1/30   Eth100/1/29 
                     Eth100/1/28   Eth100/1/27   Eth100/1/26   Eth100/1/25 
                     Eth100/1/24   Eth100/1/23   Eth100/1/22   Eth100/1/21 
                     Eth100/1/20   Eth100/1/19   Eth100/1/18   Eth100/1/17 
                     Eth100/1/16   Eth100/1/15   Eth100/1/14   Eth100/1/13 
                     Eth100/1/12   Eth100/1/11   Eth100/1/10   Eth100/1/9  
                     Eth100/1/8    Eth100/1/7    Eth100/1/6    Eth100/1/5  
                     Eth100/1/4    Eth100/1/3    Eth100/1/2    Eth100/1/1
    ===============================
    N5K-01(config-if)# sh fex 100 detail
    FEX: 100 Description: FEX0100   state: Offline
      FEX version: 4.1(3)N2(1a) [Switch version: 4.1(3)N2(1a)]
      FEX Interim version: 4.1(3)N2(1a)
      Switch Interim version: 4.1(3)N2(1a)
      Extender Model: N2K-C2148T-1GE,  Extender Serial: JAF1405CKHC
      Part No: 73-12009-06
      Card Id: 70, Mac Addr: 00:0d:ec:fd:48:82, Num Macs: 64
      Module Sw Gen: 12594  [Switch Sw Gen: 21]
    pinning-mode: static    Max-links: 1
      Fabric port for control traffic: Eth1/4
      Fabric interface state:
        Eth1/4 - Interface Up. State: Active
      Fex Port        State  Fabric Port  Primary Fabric
           Eth100/1/1  Down      Eth1/4      Eth1/4
           Eth100/1/2  Down      Eth1/4      Eth1/4
           Eth100/1/3  Down      Eth1/4      Eth1/4
           Eth100/1/4  Down      Eth1/4      Eth1/4
           Eth100/1/5  Down      Eth1/4      Eth1/4
           Eth100/1/6  Down      Eth1/4      Eth1/4
           Eth100/1/7  Down      Eth1/4      Eth1/4
           Eth100/1/8  Down      Eth1/4      Eth1/4
           Eth100/1/9  Down      Eth1/4      Eth1/4
          Eth100/1/10  Down      Eth1/4      Eth1/4
          Eth100/1/11  Down      Eth1/4      Eth1/4
          Eth100/1/12  Down      Eth1/4      Eth1/4
          Eth100/1/13  Down      Eth1/4      Eth1/4
          Eth100/1/14  Down      Eth1/4      Eth1/4
          Eth100/1/15  Down      Eth1/4      Eth1/4
          Eth100/1/16  Down      Eth1/4      Eth1/4
          Eth100/1/17  Down      Eth1/4      Eth1/4
          Eth100/1/18  Down      Eth1/4      Eth1/4
          Eth100/1/19  Down      Eth1/4      Eth1/4
          Eth100/1/20  Down      Eth1/4      Eth1/4
          Eth100/1/21  Down      Eth1/4      Eth1/4
          Eth100/1/22  Down      Eth1/4      Eth1/4
          Eth100/1/23  Down      Eth1/4      Eth1/4
          Eth100/1/24  Down      Eth1/4      Eth1/4
          Eth100/1/25  Down      Eth1/4      Eth1/4
          Eth100/1/26  Down      Eth1/4      Eth1/4
          Eth100/1/27  Down      Eth1/4      Eth1/4
          Eth100/1/28  Down      Eth1/4      Eth1/4
          Eth100/1/29  Down      Eth1/4      Eth1/4
          Eth100/1/30  Down      Eth1/4      Eth1/4
          Eth100/1/31  Down      Eth1/4      Eth1/4
          Eth100/1/32  Down      Eth1/4      Eth1/4
          Eth100/1/33  Down      Eth1/4      Eth1/4
          Eth100/1/34  Down      Eth1/4      Eth1/4
          Eth100/1/35  Down      Eth1/4      Eth1/4
          Eth100/1/36  Down      Eth1/4      Eth1/4
          Eth100/1/37  Down      Eth1/4      Eth1/4
          Eth100/1/38  Down      Eth1/4      Eth1/4
          Eth100/1/39  Down      Eth1/4      Eth1/4
          Eth100/1/40  Down      Eth1/4      Eth1/4
          Eth100/1/41  Down      Eth1/4      Eth1/4
          Eth100/1/42  Down      Eth1/4      Eth1/4
          Eth100/1/43  Down      Eth1/4      Eth1/4
          Eth100/1/44  Down      Eth1/4      Eth1/4
          Eth100/1/45  Down      Eth1/4      Eth1/4
          Eth100/1/46  Down      Eth1/4      Eth1/4
          Eth100/1/47  Down      Eth1/4      Eth1/4
          Eth100/1/48  Down      Eth1/4      Eth1/4
    Logs:
    [11/24/2010 03:16:20.624283] Module register received
    [11/24/2010 03:16:20.627639] Registration response sent
    [11/24/2010 03:16:21.115021] Module Online Sequence
    [11/24/2010 03:16:22.379395] Module Online
    [11/24/2010 03:52:09.779773] Module disconnected
    [11/24/2010 03:52:09.781691] Offlining Module
    [11/24/2010 03:52:09.782231] Module Offline Sequence
    [11/24/2010 03:52:11.735462] Module Offline
    [11/24/2010 04:06:25.258659] Module disconnected
    [11/24/2010 04:06:25.259890] Offlining Module
    =================
    N5K-02# sh fex 100 detail
    FEX: 100 Description: FEX0100   state: Online
      FEX version: 4.1(3)N2(1a) [Switch version: 4.1(3)N2(1a)]
      FEX Interim version: 4.1(3)N2(1a)
      Switch Interim version: 4.1(3)N2(1a)
      Extender Model: N2K-C2148T-1GE,  Extender Serial: JAF1405CKHC
      Part No: 73-12009-06
      Card Id: 70, Mac Addr: 00:0d:ec:fd:48:82, Num Macs: 64
      Module Sw Gen: 12594  [Switch Sw Gen: 21]
    pinning-mode: static    Max-links: 1
      Fabric port for control traffic: Eth1/4
      Fabric interface state:
        Eth1/4 - Interface Up. State: Active
      Fex Port        State  Fabric Port  Primary Fabric
           Eth100/1/1  Down      Eth1/4      Eth1/4
           Eth100/1/2  Down      Eth1/4      Eth1/4
           Eth100/1/3  Down      Eth1/4      Eth1/4
           Eth100/1/4  Down      Eth1/4      Eth1/4
           Eth100/1/5  Down      Eth1/4      Eth1/4
           Eth100/1/6  Down      Eth1/4      Eth1/4
           Eth100/1/7  Down      Eth1/4      Eth1/4
           Eth100/1/8  Down      Eth1/4      Eth1/4
           Eth100/1/9  Down      Eth1/4      Eth1/4
          Eth100/1/10  Down      Eth1/4      Eth1/4
          Eth100/1/11  Down      Eth1/4      Eth1/4
          Eth100/1/12  Down      Eth1/4      Eth1/4
          Eth100/1/13  Down      Eth1/4      Eth1/4
          Eth100/1/14  Down      Eth1/4      Eth1/4
          Eth100/1/15  Down      Eth1/4      Eth1/4
          Eth100/1/16  Down      Eth1/4      Eth1/4
          Eth100/1/17  Down      Eth1/4      Eth1/4
          Eth100/1/18  Down      Eth1/4      Eth1/4
          Eth100/1/19  Down      Eth1/4      Eth1/4
          Eth100/1/20  Down      Eth1/4      Eth1/4
          Eth100/1/21  Down      Eth1/4      Eth1/4
          Eth100/1/22  Down      Eth1/4      Eth1/4
          Eth100/1/23  Down      Eth1/4      Eth1/4
          Eth100/1/24  Down      Eth1/4      Eth1/4
          Eth100/1/25  Down      Eth1/4      Eth1/4
          Eth100/1/26  Down      Eth1/4      Eth1/4
          Eth100/1/27  Down      Eth1/4      Eth1/4
          Eth100/1/28  Down      Eth1/4      Eth1/4
          Eth100/1/29  Down      Eth1/4      Eth1/4
          Eth100/1/30  Down      Eth1/4      Eth1/4
          Eth100/1/31  Down      Eth1/4      Eth1/4
          Eth100/1/32  Down      Eth1/4      Eth1/4
          Eth100/1/33  Down      Eth1/4      Eth1/4
          Eth100/1/34  Down      Eth1/4      Eth1/4
          Eth100/1/35  Down      Eth1/4      Eth1/4
          Eth100/1/36  Down      Eth1/4      Eth1/4
          Eth100/1/37  Down      Eth1/4      Eth1/4
          Eth100/1/38  Down      Eth1/4      Eth1/4
          Eth100/1/39  Down      Eth1/4      Eth1/4
          Eth100/1/40  Down      Eth1/4      Eth1/4
          Eth100/1/41  Down      Eth1/4      Eth1/4
          Eth100/1/42  Down      Eth1/4      Eth1/4
          Eth100/1/43  Down      Eth1/4      Eth1/4
          Eth100/1/44  Down      Eth1/4      Eth1/4
          Eth100/1/45  Down      Eth1/4      Eth1/4
          Eth100/1/46  Down      Eth1/4      Eth1/4
          Eth100/1/47  Down      Eth1/4      Eth1/4
          Eth100/1/48  Down      Eth1/4      Eth1/4
    Logs:
    [11/24/2010 03:49:38.824900] Module timed out
    [11/24/2010 03:54:08.225000] Module register received
    [11/24/2010 03:54:08.226093] Registration response sent
    [11/24/2010 03:54:08.540805] Module Online Sequence
    [11/24/2010 03:54:10.7287] Module Online
    Anyone can help me with this?
    Thanks.

    I already configured vPC between 2 Nexus 5010
    N5K-01# sh vpc brief
    Legend:
                    (*) - local vPC is down, forwarding via vPC peer-link
    vPC domain id                   : 1  
    Peer status                     : peer adjacency formed ok     
    vPC keep-alive status           : peer is alive                
    Configuration consistency status: success
    vPC role                        : primary                     
    vPC Peer-link status
    id   Port   Status Active vlans   
    1    Po1    up     1                                                      
    vPC status
    id     Port        Status Consistency Reason                     Active vlans
    100    Po100       down   success     success                    - 
    N5K-02# sh vpc
    Legend:
                    (*) - local vPC is down, forwarding via vPC peer-link
    vPC domain id                   : 1  
    Peer status                     : peer adjacency formed ok     
    vPC keep-alive status           : peer is alive                
    Configuration consistency status: success
    vPC role                        : secondary                   
    vPC Peer-link status
    id   Port   Status Active vlans   
    1    Po1    up     1                                                      
    vPC status
    id     Port        Status Consistency Reason                     Active vlans
    100    Po100       down*  success     success                    -        
    N5K-02#
    may i miss some config ?

  • Connecting a WS-C4948 to a Nexus 5010

    is it possible to connect a WS-C4948 switch to a Nexus 5010? I have a flat network with no vlans.I know you are suppose to use the first 8 ports of the Nexus to get it to be on a 1GB port. What gbic am i to use on the ws-c4948 switch? if using a fiber cable or a rj45 cable?

    I was able to get it to work.....thank  you for the guys who responded!!
    configuration on the WS-C4948:
    interface GigabitEthernet1/48
    description connection to nexus5010
    media-type rj45
    interface Vlan1
    ip address 10.x.x.226 255.0.0.0
    ip default-gateway 10.x.x.1
    configuration on the Nexus 5010:
    vrf context management
    vlan 1
    interface Vlan1
      no shutdown
      ip address 10.x.x.223/8
    interface Ethernet1/1
      switchport mode trunk
      speed 1000
    steps on adding vlan 1 and adding an IP address on the Nexus 5010:
    - remove int mgmt 0, ip address and vrf context management
    nexus5010(config)# int mgmt 0
    nexus5010(config-if)# no ip address
    nexus5010(config-if)# vrf context management
    nexus5010(config-vrf)# no ip route 0.0.0.0/0 10.x.x.1
    nexus5010(config-vrf)# exit
    - turn on feature interface-vlan, create int vlan 1, add IP address, no shut, add vrf context default
    nexus5010(config)# feature interface-vlan
    nexus5010(config)# int vlan 1
    nexus5010(config-if)# ip address 10.x.x.223/8
    nexus5010(config-if)# no shut
    nexus5010(config-if)# exit
    nexus5010(config)# vlan 1
    nexus5010(config-vlan)# exit
    nexus5010(config)# vrf context default
    nexus5010(config)# ip route 0.0.0.0/0 10.x.x.1
    nexus5010(config)# exit

  • Nexus 5010 VPC noOperMem

    I'm trying to set up a vpc between two Nexus 5010s going to an HP VMware chassis..
    I'm getting the error no operational members and am not sure what I did wrong.
    I've attached the configs for VPC121, if anyone has any ideas I'd really appreciate it.

    Try rebuilding the Portchannel again
    interface Ethernet1/11
    no switchport mode trunk
    no switchport trunk allowed vlan 4,8,10,12,14,16-17,19-21,24-25,27,64,72,80,88,96,124,190,200,209,257-258,420,900,1102
    no channel-group 121 mode active
    no int po121
    new config:
    int e1/11
    channel-group 121 mode active
    The command above should create po 121 for you
    int po121
    switchport mode trunk
    switchport trunk allowed vlan 4,8,10,12,14,16-17,19-21,24-25,27,64,72,80,88,96,124,190,200,209,257-258,420,900,1102
    no sh
    now test again
    HTH

  • Cisco Nexus 5010 FCOE Interconnection

    Hi, i would really apreciate your help on this  doubt.
    Is it possible to create a link between two cisco nexus 5010
    using  CNA interfaces ?
    I've already configured the ethernet interfaces(where the cna is plugged in),
    i've binded the E1/2, mapped the vsan, created specific traffic vlan, and so on ...
    I have  tried everything what's written in the manual but the vcf interface won't set up, keeps telling me "vcf is down" .
    What am i doing wrong ? or this connection is imposible ...
    Thanks in advance.

    5020A.1# show vlan fcoe
    Original VLAN ID        Translated VSAN ID      Association State
          100                       100              Operational
    5020A.1# sho feature | grep np
    npiv                  1         disabled
    npv                   1         enabled
    5020A.1# sho interface brief | grep -i fc
    fc2/3      100    NP     off     up               swl    NP      4    --
    fc2/4      100    NP     off     up               swl    NP      4    --
    vfc15      100    F      on      trunking         --     TF      auto --
    !!!here's vfc15 and it's associated interface
    5020A.1# sho run int vf15
    !Command: show running-config interface vfc15
    !Time: Thu Feb 17 12:45:29 2011
    version 5.0(2)N2(1)
    interface vfc15
      bind interface Ethernet1/15
      no shutdown
    5020A.1# show inter e1/15 status
    Port          Name               Status    Vlan      Duplex  Speed   Type
    Eth1/15       FCoE ports  connected trunk     full    10G     1/10g     
    5020A.1# sho run int e1/15
    !Command: show running-config interface Ethernet1/15
    !Time: Thu Feb 17 12:45:33 2011
    version 5.0(2)N2(1)
    interface Ethernet1/15
      description FCoE ports
      switchport mode trunk
      switchport trunk allowed vlan 1,10,30,100
      spanning-tree port type edge trunk
      load-interval counter 2 30
      load-interval counter 3 30
    5020A.1#
    5020A.1#
    5020A.1#
    I'd use this to get a look at FIP
    ethanalyzer local sniff-interface inbound-hi detailed-dissection display-filter vlan.etype==0x8914 limit-captured 200 write bootflash:fipcap1.pcap
    This is assuming that your eth1/2 is working and up.
    reply w/your associated show commands
    show fcoe vlan
    show feature | grep np
    show interface brief | grep -i fc
    show vsan
    sho run inter vfc x
    show run inter eth x/y
    show inter eth x/y status
    other questions
    1. what OS?
    2. what vendor of CNA card?
    Joe

  • Nexus 5010/20 Vs Nexus 5548

    Is there any difference between 5010/20 and 5548 in functionality for NAS?
    I am using Nexus 5010 between UCS FIC and Array.
    I am aware of the differences in port density, unified ports, L3 support etc etc.
    Fundamentally what do I loose if I am just testing using 5010 compared to 5548.

    Hi Steve,
    Thanks for the reply, this is the version currently running on the Nexus 5K:
    Software
      BIOS:      version 1.5.0
      loader:    version N/A
      kickstart: version 5.1(3)N2(1b)
      system:    version 5.1(3)N2(1b)
      power-seq: Module 1: version v1.2
      BIOS compile time:       11/30/10
      kickstart image file is: bootflash:///n5000-uk9-kickstart.5.1.3.N2.1b.bin
      kickstart compile time:  8/31/2012 17:00:00 [08/31/2012 17:30:27]
      system image file is:    bootflash:///n5000-uk9.5.1.3.N2.1b.bin
      system compile time:     8/31/2012 17:00:00 [08/31/2012 18:29:34]
    Regards,
    -Michael

  • LMS 3.2: RME failed archive with Nexus 5010

    Hi,
    LMS 3.2, RME 4.3.1, dev packages updated, Windows.
    We would like to archive the configuration of the Nexus 5010 switches. Due to authentication with Radius based on tokens we're not able to use telnet/SSH and therefore we only can use SNMP WRite in combination with TFTP.  But, this is not working at all. Other systems like 3750 works fine. Is there a difference between Catalysts IOS and nexus NXOS?
    I searched the forum and found this:
    https://supportforums.cisco.com/message/663481#663481
    upgrade to LMS 2.6, archive config not working anymore
    We ship and start a TFTP server by default on Windows.  You must have an SNMP read-write community string configured on your devices, and entered in DCR for TFTP config fetches to work.  Additionally, udp/69 must be open between device and server.
    The easiest way to troubleshoot this kind of problem is to start a sniffer trace on the LMS server (using Device Center > Packet Capture).  Filter on all traffic to one of the failing devices.  Then, run a Sync Archive job for that same device.  When it fails, the sniffer trace will indicate what the problem is
    Regards
    Ad Olsthoorn

    Hi Lavramov,
    Yes I'm quite sure, I installed the required packages acoording to the Nexus.RME431.v2-2.readme.pdf manual. the manual tell me to install the following (see also attachement).
    To install the Cisco Nexus Series Package, you must install the following dependent packages:
    - SharedDcmaSS.RME431.v2-2.zip
    - SharedInventoryMDS.RME431.v1-5-1.zip
    - SharedSwimMDS9000.RME431.v1-6-1.zip
    - SharedNetshowSS.RME431.v1-1.zip
    regards
    Ad

  • LMS 3.2 : Can't collect inventory from Nexus 5010

    Hello,
    I've added a Nexus 5010 to LMS, and it recognized it as such, and it was also able to archive its configuration.
    But LMS is unable to collect inventory from it : the error message is "Device Sensed, but collection failed".
    I am able to do an snmp walk of the device and I do see the ENTITY mib.
    I am running LMS 3.2 with no RME patches or device package updates.
    I've attached the relevant portion of IC_Server.log.
    The Nexus 5010 is running NX-OS 4.1(3)N2(1a).
    Thanks for the help,
    Alex.

    >> I am running LMS 3.2 with no RME patches or device package updates.
    So why not update the dev pkgs, then try again?
    The latest RME pkg for Nexus is apparently v2.4, whereas I'm collecting the 5010s fine with v2.3.
    704.
    1.3.6.1.4.1.9.12.3.1.3.798
    Cisco Nexus 5010 Switch
    Nexus
    2.3

  • VLAN Support On Routers

    I recently bought an 851 only to find out afterwards that it only supports 1 VLAN when I needed it to support at least 7. The documentation on VLAN support seemed pretty buried.
    Does anyone know if there is an easy way to find out how many VLANs each router model supports? I dont' want to make the same mistake again, and I can't seem to find what I'm looking for by combing through the data sheets for each model.
    Thanks!
    Sorry, I meant to post this in the routing and switching forum and I can't figure out how to delete the thread.

    Hi
    A maximum of four VLANs are supported on the Cisco 870 Series with the plus feature set (Advanced IP Services/Advanced Enterprise Services) Cisco IOS. The Cisco 850 Series only supports one 802.1q VLAN.
    See this link http://www.cisco.com/en/US/products/hw/routers/ps380/products_qanda_item0900aecd8028a982.shtml

  • [Q]:  OracleVM VLAN Support with same subnets

    Can I create OracleVM Network VLAN pool that would allow for two vlans to use the same network topology or segment. Meaning, does the VLAN know how to tag the vlan I created to know which vlan the traffic came from and route back to the proper vlan. For example, VLAN1 - 192.168.1.0 and have any machines assigned to this vlan to only communicate with other machines on VLAN1. And have VLAN2 on the same network defined private segment with 192.168.1.0 network. BUT, is OVM aware of the tagging of VLAN1 and to route information back to the proper VLAN?
    TIA

    VLAN tagging is independant - and of course must be, since it belongs to layer 2 of the OSI model, of the IP network that is run on it. You musn't confuse the network switches PVID (aka untagged VLAN support) which tagg an incoming packet on a switch port to a specific VLAN.
    If you configure VLANs in OVM your're absolutely free to use whatever ip network you want on it - the traffic will stay seperated, since your're running it on a - although virtual - separate LAN.

  • ArchLinux VLAN support

    Hi,
    I've hacked vlan support into the arch init, at least, I haven't been able to test this really, I have no vlan capable switch... This might be of use to some people, or may not... (it also includes my bonding support)
    /etc/rc.d/network:
    #!/bin/bash
    . /etc/rc.conf
    . /etc/rc.d/functions
    ifup()
    varname="$${1}"
    eval new_ifline=$varname
    vlanname="$${1}_vlan"
    eval new_vlline=$vlanname
    if [[ $1 != bond[0-9]*_slaves ]]; then
    # its a normal interface
    if [ "$new_ifline" = "dhcp" ]; then
    # remove the .pid file if it exists
    rm -f /etc/dhcpc/dhcpcd-${1}.{pid,cache} >/dev/null 2>&1
    /usr/sbin/dhcpcd -t 10 -h $HOSTNAME $1
    else
    /sbin/ifconfig $1 $new_ifline up
    fi
    if [ "$new_vlline" != "" ]; then
    vconfig add $1 $new_vlline
    fi
    else
    # its a bonding interface
    for slave_if in ${new_ifline[@]}; do
    if echo $slave_if | grep '^[^!]' >/dev/null 2>&1; then
    /sbin/ifenslave ${1/_slaves} $slave_if
    fi
    done
    fi
    return $?
    ifdown()
    varname="$${1}"
    eval new_ifline=$varname
    if [[ $1 != bond[0-9]*_slaves ]]; then
    if [ "$new_ifline" = "dhcp" ]; then
    [ -f /etc/dhcpc/dhcpcd-${1}.pid ] &&
    /bin/kill `cat /etc/dhcpc/dhcpcd-${1}.pid`
    else
    /sbin/ifconfig $1 $new_ifline down
    fi
    fi
    return $?
    rtup()
    varname="$${1}"
    eval new_rtline=$varname
    /sbin/route add $new_rtline
    return $?
    rtdown()
    varname="$${1}"
    eval new_rtline=$varname
    /sbin/route del $new_rtline
    return $?
    case "$1" in
    start)
    if ! ck_daemon network; then
    echo "Network is already running. Try 'network restart'"
    exit
    fi
    stat_busy "Starting Network"
    error=0
    for ifline in ${INTERFACES[@]}; do
    if echo $ifline | grep '^[^!]' >/dev/null 2>&1; then
    ifup $ifline || error=1
    fi
    done
    for rtline in "${ROUTES[@]}"; do
    if echo $rtline | grep '^[^!]' 2>&1 >/dev/null; then
    rtup $rtline || error=1
    fi
    done
    if [ $error -eq 0 ]; then
    add_daemon network
    stat_done
    else
    stat_fail
    fi
    stop)
    if ck_daemon network; then
    echo "Network is not running. Try 'network start'"
    exit
    fi
    stat_busy "Stopping Network"
    rm_daemon network
    error=0
    for rtline in "${ROUTES[@]}"; do
    if echo $rtline | grep '^[^!]' 2>&1 >/dev/null; then
    rtdown $rtline || error=1
    fi
    done
    for ifline in ${INTERFACES[@]}; do
    if echo $ifline | grep '^[^!]' 2>&1 >/dev/null; then
    ifdown $ifline || error=1
    fi
    done
    if [ $error -eq 0 ]; then
    stat_done
    else
    stat_fail
    fi
    restart)
    $0 stop
    sleep 2
    $0 start
    echo "usage: $0 {start|stop|restart}"
    esac
    Please do backup your own /etc/rc.d/network script, just in case!
    Good luck,
    Pascal de Bruijn

    How do you have your h-reap setup... how many ssid's for example? If dhcp is local, for all ssid's, then all ssid's must have local switching on unless clients will get tunneled back to the wlc and obtain an ip address there. When you say... turn on and off vlan support, you talking about the native vlan setting in the h-reap ap?

Maybe you are looking for

  • Can I install photoshop on more than one computer?

    I just purchased a new Mac and downloaded CS6, which I purchased in July of 2013 and installed on my old PC.  After the install when I tried to enter my serial #, it told me it was invalid.  Is this because I can only install it on one computer or am

  • Doubt on servlet architecture, URGENT

    Hello Java experts!! Please claurify my small doubt In servlet architecture, if i write one servlet, multi threading concept of servlets will be implemented in Servlet level or doPost(doGet) level. Because I wrote all functions out side the dopost me

  • Temp file save location

    1st Why is Itunes creating so many temp files? 2nd Can I change where Itunes saves these file? They are saving on "my music" folder which is part of our server, wasting valuable space. If I have to have these files I would like to save them to my C:

  • Where is the image attachment resize function in Mail?

    I have not been able to find an answer to where the resize function in Mail on SnowLeopard has gone in MountainLion. Which I just updated to, skipping Lion. thank you for your time.

  • Setup of latest BI-Publisher failing

    Hi, I have downloaded "BI Publisher 10.1.3.4.1 for Windows x86" from the below link http://www.oracle.com/technology/software/products/publishing/index.html I tried to install this on windows xp machine. I am getting setup error while running setup.e