Nexus 5010 VPC noOperMem
I'm trying to set up a vpc between two Nexus 5010s going to an HP VMware chassis..
I'm getting the error no operational members and am not sure what I did wrong.
I've attached the configs for VPC121, if anyone has any ideas I'd really appreciate it.
Try rebuilding the Portchannel again
interface Ethernet1/11
no switchport mode trunk
no switchport trunk allowed vlan 4,8,10,12,14,16-17,19-21,24-25,27,64,72,80,88,96,124,190,200,209,257-258,420,900,1102
no channel-group 121 mode active
no int po121
new config:
int e1/11
channel-group 121 mode active
The command above should create po 121 for you
int po121
switchport mode trunk
switchport trunk allowed vlan 4,8,10,12,14,16-17,19-21,24-25,27,64,72,80,88,96,124,190,200,209,257-258,420,900,1102
no sh
now test again
HTH
Similar Messages
-
Fex 1 Nexus 2148 to 2 Nexus 5010 problem?
hi all
I'm having trouble when fex(ing) 1 nexus 2000 to 2 nexus 5000.
I've configured as dual home from 1 nexus 2k. But after success config, just 1 nexus 5k can see 48 port on it. other cannot see it and it showed as module offline
Here's is results:
N5K-01(config-if)# sh int e1/4 fex-intf
Fabric FEX
Interface Interfaces
Eth1/4
N5K-01(config-if)#
N5K-02# sh int e1/4 fex-intf
Fabric FEX
Interface Interfaces
Eth1/4 Eth100/1/48 Eth100/1/47 Eth100/1/46 Eth100/1/45
Eth100/1/44 Eth100/1/43 Eth100/1/42 Eth100/1/41
Eth100/1/40 Eth100/1/39 Eth100/1/38 Eth100/1/37
Eth100/1/36 Eth100/1/35 Eth100/1/34 Eth100/1/33
Eth100/1/32 Eth100/1/31 Eth100/1/30 Eth100/1/29
Eth100/1/28 Eth100/1/27 Eth100/1/26 Eth100/1/25
Eth100/1/24 Eth100/1/23 Eth100/1/22 Eth100/1/21
Eth100/1/20 Eth100/1/19 Eth100/1/18 Eth100/1/17
Eth100/1/16 Eth100/1/15 Eth100/1/14 Eth100/1/13
Eth100/1/12 Eth100/1/11 Eth100/1/10 Eth100/1/9
Eth100/1/8 Eth100/1/7 Eth100/1/6 Eth100/1/5
Eth100/1/4 Eth100/1/3 Eth100/1/2 Eth100/1/1
===============================
N5K-01(config-if)# sh fex 100 detail
FEX: 100 Description: FEX0100 state: Offline
FEX version: 4.1(3)N2(1a) [Switch version: 4.1(3)N2(1a)]
FEX Interim version: 4.1(3)N2(1a)
Switch Interim version: 4.1(3)N2(1a)
Extender Model: N2K-C2148T-1GE, Extender Serial: JAF1405CKHC
Part No: 73-12009-06
Card Id: 70, Mac Addr: 00:0d:ec:fd:48:82, Num Macs: 64
Module Sw Gen: 12594 [Switch Sw Gen: 21]
pinning-mode: static Max-links: 1
Fabric port for control traffic: Eth1/4
Fabric interface state:
Eth1/4 - Interface Up. State: Active
Fex Port State Fabric Port Primary Fabric
Eth100/1/1 Down Eth1/4 Eth1/4
Eth100/1/2 Down Eth1/4 Eth1/4
Eth100/1/3 Down Eth1/4 Eth1/4
Eth100/1/4 Down Eth1/4 Eth1/4
Eth100/1/5 Down Eth1/4 Eth1/4
Eth100/1/6 Down Eth1/4 Eth1/4
Eth100/1/7 Down Eth1/4 Eth1/4
Eth100/1/8 Down Eth1/4 Eth1/4
Eth100/1/9 Down Eth1/4 Eth1/4
Eth100/1/10 Down Eth1/4 Eth1/4
Eth100/1/11 Down Eth1/4 Eth1/4
Eth100/1/12 Down Eth1/4 Eth1/4
Eth100/1/13 Down Eth1/4 Eth1/4
Eth100/1/14 Down Eth1/4 Eth1/4
Eth100/1/15 Down Eth1/4 Eth1/4
Eth100/1/16 Down Eth1/4 Eth1/4
Eth100/1/17 Down Eth1/4 Eth1/4
Eth100/1/18 Down Eth1/4 Eth1/4
Eth100/1/19 Down Eth1/4 Eth1/4
Eth100/1/20 Down Eth1/4 Eth1/4
Eth100/1/21 Down Eth1/4 Eth1/4
Eth100/1/22 Down Eth1/4 Eth1/4
Eth100/1/23 Down Eth1/4 Eth1/4
Eth100/1/24 Down Eth1/4 Eth1/4
Eth100/1/25 Down Eth1/4 Eth1/4
Eth100/1/26 Down Eth1/4 Eth1/4
Eth100/1/27 Down Eth1/4 Eth1/4
Eth100/1/28 Down Eth1/4 Eth1/4
Eth100/1/29 Down Eth1/4 Eth1/4
Eth100/1/30 Down Eth1/4 Eth1/4
Eth100/1/31 Down Eth1/4 Eth1/4
Eth100/1/32 Down Eth1/4 Eth1/4
Eth100/1/33 Down Eth1/4 Eth1/4
Eth100/1/34 Down Eth1/4 Eth1/4
Eth100/1/35 Down Eth1/4 Eth1/4
Eth100/1/36 Down Eth1/4 Eth1/4
Eth100/1/37 Down Eth1/4 Eth1/4
Eth100/1/38 Down Eth1/4 Eth1/4
Eth100/1/39 Down Eth1/4 Eth1/4
Eth100/1/40 Down Eth1/4 Eth1/4
Eth100/1/41 Down Eth1/4 Eth1/4
Eth100/1/42 Down Eth1/4 Eth1/4
Eth100/1/43 Down Eth1/4 Eth1/4
Eth100/1/44 Down Eth1/4 Eth1/4
Eth100/1/45 Down Eth1/4 Eth1/4
Eth100/1/46 Down Eth1/4 Eth1/4
Eth100/1/47 Down Eth1/4 Eth1/4
Eth100/1/48 Down Eth1/4 Eth1/4
Logs:
[11/24/2010 03:16:20.624283] Module register received
[11/24/2010 03:16:20.627639] Registration response sent
[11/24/2010 03:16:21.115021] Module Online Sequence
[11/24/2010 03:16:22.379395] Module Online
[11/24/2010 03:52:09.779773] Module disconnected
[11/24/2010 03:52:09.781691] Offlining Module
[11/24/2010 03:52:09.782231] Module Offline Sequence
[11/24/2010 03:52:11.735462] Module Offline
[11/24/2010 04:06:25.258659] Module disconnected
[11/24/2010 04:06:25.259890] Offlining Module
=================
N5K-02# sh fex 100 detail
FEX: 100 Description: FEX0100 state: Online
FEX version: 4.1(3)N2(1a) [Switch version: 4.1(3)N2(1a)]
FEX Interim version: 4.1(3)N2(1a)
Switch Interim version: 4.1(3)N2(1a)
Extender Model: N2K-C2148T-1GE, Extender Serial: JAF1405CKHC
Part No: 73-12009-06
Card Id: 70, Mac Addr: 00:0d:ec:fd:48:82, Num Macs: 64
Module Sw Gen: 12594 [Switch Sw Gen: 21]
pinning-mode: static Max-links: 1
Fabric port for control traffic: Eth1/4
Fabric interface state:
Eth1/4 - Interface Up. State: Active
Fex Port State Fabric Port Primary Fabric
Eth100/1/1 Down Eth1/4 Eth1/4
Eth100/1/2 Down Eth1/4 Eth1/4
Eth100/1/3 Down Eth1/4 Eth1/4
Eth100/1/4 Down Eth1/4 Eth1/4
Eth100/1/5 Down Eth1/4 Eth1/4
Eth100/1/6 Down Eth1/4 Eth1/4
Eth100/1/7 Down Eth1/4 Eth1/4
Eth100/1/8 Down Eth1/4 Eth1/4
Eth100/1/9 Down Eth1/4 Eth1/4
Eth100/1/10 Down Eth1/4 Eth1/4
Eth100/1/11 Down Eth1/4 Eth1/4
Eth100/1/12 Down Eth1/4 Eth1/4
Eth100/1/13 Down Eth1/4 Eth1/4
Eth100/1/14 Down Eth1/4 Eth1/4
Eth100/1/15 Down Eth1/4 Eth1/4
Eth100/1/16 Down Eth1/4 Eth1/4
Eth100/1/17 Down Eth1/4 Eth1/4
Eth100/1/18 Down Eth1/4 Eth1/4
Eth100/1/19 Down Eth1/4 Eth1/4
Eth100/1/20 Down Eth1/4 Eth1/4
Eth100/1/21 Down Eth1/4 Eth1/4
Eth100/1/22 Down Eth1/4 Eth1/4
Eth100/1/23 Down Eth1/4 Eth1/4
Eth100/1/24 Down Eth1/4 Eth1/4
Eth100/1/25 Down Eth1/4 Eth1/4
Eth100/1/26 Down Eth1/4 Eth1/4
Eth100/1/27 Down Eth1/4 Eth1/4
Eth100/1/28 Down Eth1/4 Eth1/4
Eth100/1/29 Down Eth1/4 Eth1/4
Eth100/1/30 Down Eth1/4 Eth1/4
Eth100/1/31 Down Eth1/4 Eth1/4
Eth100/1/32 Down Eth1/4 Eth1/4
Eth100/1/33 Down Eth1/4 Eth1/4
Eth100/1/34 Down Eth1/4 Eth1/4
Eth100/1/35 Down Eth1/4 Eth1/4
Eth100/1/36 Down Eth1/4 Eth1/4
Eth100/1/37 Down Eth1/4 Eth1/4
Eth100/1/38 Down Eth1/4 Eth1/4
Eth100/1/39 Down Eth1/4 Eth1/4
Eth100/1/40 Down Eth1/4 Eth1/4
Eth100/1/41 Down Eth1/4 Eth1/4
Eth100/1/42 Down Eth1/4 Eth1/4
Eth100/1/43 Down Eth1/4 Eth1/4
Eth100/1/44 Down Eth1/4 Eth1/4
Eth100/1/45 Down Eth1/4 Eth1/4
Eth100/1/46 Down Eth1/4 Eth1/4
Eth100/1/47 Down Eth1/4 Eth1/4
Eth100/1/48 Down Eth1/4 Eth1/4
Logs:
[11/24/2010 03:49:38.824900] Module timed out
[11/24/2010 03:54:08.225000] Module register received
[11/24/2010 03:54:08.226093] Registration response sent
[11/24/2010 03:54:08.540805] Module Online Sequence
[11/24/2010 03:54:10.7287] Module Online
Anyone can help me with this?
Thanks.I already configured vPC between 2 Nexus 5010
N5K-01# sh vpc brief
Legend:
(*) - local vPC is down, forwarding via vPC peer-link
vPC domain id : 1
Peer status : peer adjacency formed ok
vPC keep-alive status : peer is alive
Configuration consistency status: success
vPC role : primary
vPC Peer-link status
id Port Status Active vlans
1 Po1 up 1
vPC status
id Port Status Consistency Reason Active vlans
100 Po100 down success success -
N5K-02# sh vpc
Legend:
(*) - local vPC is down, forwarding via vPC peer-link
vPC domain id : 1
Peer status : peer adjacency formed ok
vPC keep-alive status : peer is alive
Configuration consistency status: success
vPC role : secondary
vPC Peer-link status
id Port Status Active vlans
1 Po1 up 1
vPC status
id Port Status Consistency Reason Active vlans
100 Po100 down* success success -
N5K-02#
may i miss some config ? -
Can't archive nexus 5010 configs (LMS 3.2)
Using LMS 3.2 I can't archive configs from
our Nexus 5010 ( 4.2(1)N1(1) ) devices . I have installed
the necessary device package Nexus.RME431.v2-4.zip. Following error occures:
*** Device Details for gf02na50050p ***
Protocol ==> Unknown / Not Applicable
Selected Protocols with order ==> SSH,SCP,TFTP,RCP,Telnet
Execution Result:
RUNNING
CM0151 PRIMARY RUNNING Config fetch failed for gf02na50050p Cause: Failed to fetch config using TFTPFailed to establish TELNET connection to 10.92.170.214 - Cause: Connection refused.
Action: Check if protocol is supported by device and required device package is installed. Check device credentials. Increase timeout value, if required.
Telnet on device is disabled, SSH enabled.
with only SSH on RME followig error:
*** Device Details for gf02na50050p ***
Protocol ==> Unknown / Not Applicable
Selected Protocols with order ==> SSH
Execution Result:
RUNNING
CM0151 PRIMARY RUNNING Config fetch failed for gf02na50050p Cause: Failed to get the start tag-Building Configuration ... in the configuration. Action: Check if protocol is supported by device and required device package is installed. Check device credentials. Increase timeout value, if required.
Thanks
IgorRME 4.3.1; windows platform
with one customer I have the same issue with a Nexus 5020. Software version is :
Software
BIOS: version 1.3.0 [last: ]
loader: version N/A
kickstart: version 4.2(1)N2(1)
system: version 4.2(1)N2(1)
power-seq: version v1.2
BIOS compile time: 09/08/09 [last: ]
kickstart image file is: bootflash:///n5000-uk9-kickstart.4.2.1.N2.1.bin
kickstart compile time: 7/28/2010 18:00:00 [07/29/2010 03:10:19]
system image file is: bootflash:/n5000-uk9.4.2.1.N2.1.bin
system compile time: 7/28/2010 18:00:00 [07/29/2010 07:18:12]
Hardware
cisco Nexus5020 Chassis ("40x10GE/Supervisor")
Intel(R) Celeron(R) M CPU with 2074284 kB of memory.
===============
following RME packages are installed:
SharedNetshowSS 1.1.2 SharedNetshowSS device package
SharedSwimMDS9000 1.6.3 SharedSwimMDS9000 device package
SharedInventoryMDS 1.5.1 SharedInventoryMDS device package
SharedDcmaSS 2.2.2 SharedDcmaSS device package
Nexus 2.4 Nexus device package
===============
>>> I see the following problems with SSH instrumentation of the Nexus Platform when looking into the debug file. The file I got is more or less the same then the one Marc posted.
The customer does not have a banner configured so the standard login procedure shows the following when login is done manually. RME automatically interpretes the first line after "Login as: " as a banner...
login as: Nexus
Nexus 5000 Switch
Using keyboard-interactive authentication.
Password:
Cisco Nexus Operating System (NX-OS) Software
TAC support: http://www.cisco.com/tac
Copyright (c) 2002-2010, Cisco Systems, Inc. All rights reserved.
The copyrights to certain works contained in this software are
owned by other third parties and used and distributed under
license. Certain components of this software are licensed under
the GNU General Public License (GPL) version 2.0 or the GNU
Lesser General Public License (LGPL) Version 2.1. A copy of each
such license is available at
http://www.opensource.org/licenses/gpl-2.0.php and
http://www.opensource.org/licenses/lgpl-2.1.php
devicename#
>>> and RME wants to take the last line as the prompt, resulting in a non-fatal java exception:
[line 1471 ff.]
[ Mon Aug 30 08:58:01 CEST 2010 ],DEBUG,[Thread-38],com.cisco.nm.xms.xdi.transport.cmdsvc.LogAdapter,debug,31,Learning prompt: sA[0] == 'http://www.opensource.org/licenses/lgpl-2.1.php'
[ Mon Aug 30 08:58:01 CEST 2010 ],DEBUG,[Thread-38],com.cisco.nm.xms.xdi.transport.cmdsvc.LogAdapter,debug,31,Learning prompt: sA[1] == ''
[ Mon Aug 30 08:58:01 CEST 2010 ],DEBUG,[Thread-38],com.cisco.nm.xms.xdi.transport.cmdsvc.LogAdapter,printStackTrace,51,stacktracecom.cisco.nm.lib.cmdsvc.CmdSvcException: Prompt learning failed: 'http://www.opensource.org/licenses/lgpl-2.1.php' && '' do not match.
at com.cisco.nm.lib.cmdsvc.Session.tune(Session.java:904)
at com.cisco.nm.lib.cmdsvc.Session.tune(Session.java:833)
at com.cisco.nm.lib.cmdsvc.AuthHandler.connect(AuthHandler.java:267)
at com.cisco.nm.lib.cmdsvc.OpConnect.invoke(OpConnect.java:56)
at com.cisco.nm.lib.cmdsvc.SessionContext.invoke(SessionContext.java:299)
>> Ok, RME proceeds, but the SSH implementation (SharedDcmaSS ?) cannot extract the config and a java exception occures which leads to "Closing the session":
[ Mon Aug 30 08:58:06 CEST 2010 ],DEBUG,[Thread-38],com.cisco.nm.xms.xdi.transport.cmdsvc.LogAdapter,debug,31,Returning from Session.send('show startup-config
[ Mon Aug 30 08:58:06 CEST 2010 ],DEBUG,[Thread-38],com.cisco.nm.xms.xdi.transport.cmdsvc.LogAdapter,debug,31,in trimPrompt(), prompt == ''
[ Mon Aug 30 08:58:06 CEST 2010 ],DEBUG,[Thread-38],com.cisco.nm.xms.xdi.pkgs.LibDcma.persistor.CliOperator,fetchConfig,490,Failed to get the start tag-Building Configuration ... in the configuration.com.cisco.nm.xms.xdi.ags.config.ConfigTransportException: Failed to get the start tag-Building Configuration ... in the configuration.
at com.cisco.nm.xms.xdi.pkgs.SharedDcmaSS.transport.SSCliOperator.extractConfig2Buffer(SSCliOperator.java:176)
at com.cisco.nm.xms.xdi.pkgs.LibDcma.persistor.CliOperator.fetchConfig(CliOperator.java:436)
at com.cisco.nm.xms.xdi.pkgs.LibDcma.persistor.CliOperator.fetchConfig(CliOperator.java:510)
at com.cisco.nm.xms.xdi.pkgs.LibDcma.persistor.SimpleFetchOperation.performOperation(SimpleFetchOperation.java:61)
at com.cisco.nm.xms.xdi.pkgs.LibDcma.persistor.ConfigOperation.doConfigOperation(ConfigOperation.java:111)
at com.cisco.nm.xms.xdi.pkgs.SharedDcmaSS.transport.SSConfigOperator.fetchConfig(SSConfigOperator.java:65)
at com.cisco.nm.rmeng.dcma.configmanager.ConfigManager.updateArchiveForDevice(ConfigManager.java:1315)
at com.cisco.nm.rmeng.dcma.configmanager.ConfigManager.performCollection(ConfigManager.java:3291)
at com.cisco.nm.rmeng.dcma.configmanager.CfgUpdateThread.run(CfgUpdateThread.java:27)
[ Mon Aug 30 08:58:06 CEST 2010 ],DEBUG,[Thread-38],com.cisco.nm.xms.xdi.pkgs.LibDcma.persistor.SimpleFetchOperation,performOperation,62,FetchStatus - FAILURE for Protocol SSH for device x.x.x.x
>> As telnet and tftp are not allowed the config cannot be archived (Customer reports no problems with telnet...)
The config itself starts and ends with the following lines:
devicename# show startup-config
!Command: show startup-config
!Time: Mon Sep 6 16:41:02 2010
!Startup config saved at: Mon Aug 16 15:41:39 2010
version 4.2(1)N2(1)
no feature telnet
no telnet server enable
no feature http-server
cfs eth distribute
feature udld
feature interface-vlan
feature lacp
feature vpc
feature lldp
feature vtp
interface mgmt0
shutdown force
shutdown force
no snmp trap link-status
no snmp trap link-status
clock timezone MEZ 1 0
clock summer-time MEZS 5 sun mar 02:00 5 sun oct 03:00 60
line console
boot kickstart bootflash:/n5000-uk9-kickstart.4.2.1.N2.1.bin
boot system bootflash:/n5000-uk9.4.2.1.N2.1.bin
ip route 0.0.0.0/0 172.16.4.1
vtp mode transparent
vtp domain sap
logging server x.x.x.x 7 use-vrf default
logging server y.y.y.y 7 use-vrf default
devicename#
For me it looks like as a bug in the ssh implementation in RME, but I cannot find a bug id on CCO .... -
Nexus 5010 to Cat 6506 Sup720 using 1GB ports
Hi,
Our budget just got cut in half--sign of the times! Can I connect a Nexus 5010 to a 6506 with 6724-SFP module using a 6GB etherchannel? The 6506 has a Sup 720 and will only be used to route the VLANs. All server swithing will be done through the Nexus 5010 and 2148T.
Thanks,hi Isabel,
>> Jul 5, 2009, 9:14am PST
>> Both the Nexus 5000 and Nexus 7000 will add support for a
>> feature called Virtual Port Channels (VPC) which allows
>> the formation of multi-chassis ether channels like that
>> with VSS on the Catalyst 6500.
Nexus 7000 has had virtual Port Channel (vPC) since the release of NX-OS 4.2 around January this year.
see http://www.cisco.com/en/US/prod/collateral/switches/ps9441/ps9402/white_paper_c11-516396.html
you are correct that Nexus 5000 doesn't yet have this. N5K will gain vPC when NX-OS 4.2 is released on N5K in/on/around Q3 CY2009.
cheers,
lincoln. -
LMS 3.2: RME failed archive with Nexus 5010
Hi,
LMS 3.2, RME 4.3.1, dev packages updated, Windows.
We would like to archive the configuration of the Nexus 5010 switches. Due to authentication with Radius based on tokens we're not able to use telnet/SSH and therefore we only can use SNMP WRite in combination with TFTP. But, this is not working at all. Other systems like 3750 works fine. Is there a difference between Catalysts IOS and nexus NXOS?
I searched the forum and found this:
https://supportforums.cisco.com/message/663481#663481
upgrade to LMS 2.6, archive config not working anymore
We ship and start a TFTP server by default on Windows. You must have an SNMP read-write community string configured on your devices, and entered in DCR for TFTP config fetches to work. Additionally, udp/69 must be open between device and server.
The easiest way to troubleshoot this kind of problem is to start a sniffer trace on the LMS server (using Device Center > Packet Capture). Filter on all traffic to one of the failing devices. Then, run a Sync Archive job for that same device. When it fails, the sniffer trace will indicate what the problem is
Regards
Ad OlsthoornHi Lavramov,
Yes I'm quite sure, I installed the required packages acoording to the Nexus.RME431.v2-2.readme.pdf manual. the manual tell me to install the following (see also attachement).
To install the Cisco Nexus Series Package, you must install the following dependent packages:
- SharedDcmaSS.RME431.v2-2.zip
- SharedInventoryMDS.RME431.v1-5-1.zip
- SharedSwimMDS9000.RME431.v1-6-1.zip
- SharedNetshowSS.RME431.v1-1.zip
regards
Ad -
6500-VSS and NEXUS 56XX vPC interoperability
Hello, is it possible to establish a PORT CHANNEL between a couple of Cisco 6500 running VSS mode and a couple of NEXUS 5000 running vPC? . Design should be " Back-to-Back" : VSS-- Port-Channel--vPC.
I want also to support L2 and L3 flows between the two couples.
I read many forums but i am not sure it runs.
Is such design, if it runs; supported by Cisco?
Thanks a lot for your help.Hi Tlequertier,
We have VSS 6509Es with Sup 2Ts & 6908 modules. These have a 40gb/sec (4 x 10gb/sec) uplink to our NEXUS 5548UP vPC switches.
So we have a fully meshed ether-channel between the 4 physical switches (2 x N5548UP & 2x6509E)
Kind regards,
Tim -
LMS 3.2 : Can't collect inventory from Nexus 5010
Hello,
I've added a Nexus 5010 to LMS, and it recognized it as such, and it was also able to archive its configuration.
But LMS is unable to collect inventory from it : the error message is "Device Sensed, but collection failed".
I am able to do an snmp walk of the device and I do see the ENTITY mib.
I am running LMS 3.2 with no RME patches or device package updates.
I've attached the relevant portion of IC_Server.log.
The Nexus 5010 is running NX-OS 4.1(3)N2(1a).
Thanks for the help,
Alex.>> I am running LMS 3.2 with no RME patches or device package updates.
So why not update the dev pkgs, then try again?
The latest RME pkg for Nexus is apparently v2.4, whereas I'm collecting the 5010s fine with v2.3.
704.
1.3.6.1.4.1.9.12.3.1.3.798
Cisco Nexus 5010 Switch
Nexus
2.3 -
Connecting a WS-C4948 to a Nexus 5010
is it possible to connect a WS-C4948 switch to a Nexus 5010? I have a flat network with no vlans.I know you are suppose to use the first 8 ports of the Nexus to get it to be on a 1GB port. What gbic am i to use on the ws-c4948 switch? if using a fiber cable or a rj45 cable?
I was able to get it to work.....thank you for the guys who responded!!
configuration on the WS-C4948:
interface GigabitEthernet1/48
description connection to nexus5010
media-type rj45
interface Vlan1
ip address 10.x.x.226 255.0.0.0
ip default-gateway 10.x.x.1
configuration on the Nexus 5010:
vrf context management
vlan 1
interface Vlan1
no shutdown
ip address 10.x.x.223/8
interface Ethernet1/1
switchport mode trunk
speed 1000
steps on adding vlan 1 and adding an IP address on the Nexus 5010:
- remove int mgmt 0, ip address and vrf context management
nexus5010(config)# int mgmt 0
nexus5010(config-if)# no ip address
nexus5010(config-if)# vrf context management
nexus5010(config-vrf)# no ip route 0.0.0.0/0 10.x.x.1
nexus5010(config-vrf)# exit
- turn on feature interface-vlan, create int vlan 1, add IP address, no shut, add vrf context default
nexus5010(config)# feature interface-vlan
nexus5010(config)# int vlan 1
nexus5010(config-if)# ip address 10.x.x.223/8
nexus5010(config-if)# no shut
nexus5010(config-if)# exit
nexus5010(config)# vlan 1
nexus5010(config-vlan)# exit
nexus5010(config)# vrf context default
nexus5010(config)# ip route 0.0.0.0/0 10.x.x.1
nexus5010(config)# exit -
Nexus 5010 vlan supported limits
Hi,
Just wanted to know whether the configuration limits of 512 vlan on Nexus 5010 specified in the document below are software limitation which can be removed by adding enhanced image etc or hard limits which cannot be removed.
http://www.cisco.com/en/US/docs/switches/datacenter/nexus5000/sw/configuration_limits/limits_503/nexus_5000_config_limits_503_n1_1b.html
Regards
Vijay SequeiraHard limits. There is no special license that can increase the numbers. Nexus doesnt have the concept of enhanced images either there is a single OS image and you just unlock specific features (eg fibre channel/fcoe features) by applying licences.
-
Cisco Nexus 5010 FCOE Interconnection
Hi, i would really apreciate your help on this doubt.
Is it possible to create a link between two cisco nexus 5010
using CNA interfaces ?
I've already configured the ethernet interfaces(where the cna is plugged in),
i've binded the E1/2, mapped the vsan, created specific traffic vlan, and so on ...
I have tried everything what's written in the manual but the vcf interface won't set up, keeps telling me "vcf is down" .
What am i doing wrong ? or this connection is imposible ...
Thanks in advance.5020A.1# show vlan fcoe
Original VLAN ID Translated VSAN ID Association State
100 100 Operational
5020A.1# sho feature | grep np
npiv 1 disabled
npv 1 enabled
5020A.1# sho interface brief | grep -i fc
fc2/3 100 NP off up swl NP 4 --
fc2/4 100 NP off up swl NP 4 --
vfc15 100 F on trunking -- TF auto --
!!!here's vfc15 and it's associated interface
5020A.1# sho run int vf15
!Command: show running-config interface vfc15
!Time: Thu Feb 17 12:45:29 2011
version 5.0(2)N2(1)
interface vfc15
bind interface Ethernet1/15
no shutdown
5020A.1# show inter e1/15 status
Port Name Status Vlan Duplex Speed Type
Eth1/15 FCoE ports connected trunk full 10G 1/10g
5020A.1# sho run int e1/15
!Command: show running-config interface Ethernet1/15
!Time: Thu Feb 17 12:45:33 2011
version 5.0(2)N2(1)
interface Ethernet1/15
description FCoE ports
switchport mode trunk
switchport trunk allowed vlan 1,10,30,100
spanning-tree port type edge trunk
load-interval counter 2 30
load-interval counter 3 30
5020A.1#
5020A.1#
5020A.1#
I'd use this to get a look at FIP
ethanalyzer local sniff-interface inbound-hi detailed-dissection display-filter vlan.etype==0x8914 limit-captured 200 write bootflash:fipcap1.pcap
This is assuming that your eth1/2 is working and up.
reply w/your associated show commands
show fcoe vlan
show feature | grep np
show interface brief | grep -i fc
show vsan
sho run inter vfc x
show run inter eth x/y
show inter eth x/y status
other questions
1. what OS?
2. what vendor of CNA card?
Joe -
Private Vlan, Etherchannel and Isolated Trunk on Nexus 5010
I'm not sure if I'm missing something basic here however i though that I'd ask the question. I recieved a request from a client who is trying to seperate traffic out of a IBM P780 - one set of VIO servers/clients (Prod) is tagged with vlan x going out LAG 1 and another set of VIO server/clients (Test) is tagged with vlan y and z going out LAG 2. The problem is that the management subnet for these devices is on one subnet.
The infrastructure is the host device is trunked via LACP etherchannel to Nexus 2148TP(5010) which than connects to the distribution layer being a Catalyst 6504 VSS. I have tried many things today, however I feel that the correct solution to get this working is to use an Isolated trunk (as the host device does not have private vlan functionality) even though there is no requirement for hosts to be segregated. I have configured:
1. Private vlan mapping on the SVI;
2. Primary vlan and association, and isolated vlan on Distribution (6504 VSS) and Access Layer (5010/2148)
3. All Vlans are trunked between switches
4. Private vlan isolated trunk and host mappings on the port-channel interface to the host (P780).
I haven't had any luck. What I am seeing is as soon as I configure the Primary vlan on the Nexus 5010 (v5.2) (vlan y | private-vlan primary), this vlan (y) does not forward on any trunk on the Nexus 5010 switch, even without any other private vlan configuration. I believe this may be the cause to most of the issues I am having. Has any one else experienced this behaviour. Also, I haven't had a lot of experience with Private Vlans so I might be missing some fundamentals with this configuration. Any help would be appreciated.Hello Emcmanamy, Bruce,
Thanks for your feedback.
Just like you, I have been facing the same problematic last months with my customer.
Regarding PVLAN on FEX, and as concluded in Bruce’s previous posts I understand :
You can configure a host interface as an isolated or community access port only.
We can configure “isolated trunk port” as well on a host interface. Maybe this specific point could be updated in the documentation.
This ability is documented here =>
http://www.cisco.com/en/US/docs/switches/datacenter/nexus5000/sw/layer2/513_N2_1/b_Cisco_n5k_layer2_config_gd_rel_513_N2_1_chapter_0101.html#task_1170903
You cannot configure a host interface as a promiscuous port.
You cannot configure a host interface as a private VLAN trunk port.
Indeed a pvlan is not allowed on a trunk defined on a FEX host interface.
However since NxOS 5.1(3)N2(1), the feature 'PVLAN on FEX trunk' is supported. But a command has to be activated before => system private-vlan fex trunk . When entered a warning about the presence of ‘FEX isolated trunks’ is prompted.
http://www.cisco.com/en/US/docs/switches/datacenter/nexus5000/sw/layer2/513_N2_1/b_Cisco_n5k_layer2_config_gd_rel_513_N2_1_chapter_0101.html#task_16C0869F1B0C4A68AFC3452721909705
All these conditions are not met on a N5K interface.
Best regards.
Karim -
Nexus (5010) To FEX Distance Limitations
Hello,
My question is concerning the software-imposed distance limitations for Nexus-to-Fex connections.
With a Nexus 5010 running 4.2 (1) N1 (1) code, I believe there is a software limitation on the distance the FEX can be located from the Nexus. I have two questions concerning this:
Is there any log data, or a cli command, to verify that the fex connection has exceeded that distance?
What symptoms are produced when the fex is too far from the Nexus (ie, does the link come up but the image not load?)
I would like to determine that the reason I have a FEX, located in a second data centre, that is not coming up is actually related to the distance from the FEX to the Nexus and not related to some other problem.
Thanks for any suggestions/info offerred.
SimonI have not seen any reference to a software limitation for the distance between a N5K and a FEX.
The release notesfor 4.2(1)N1) listed si not showing it unless, my first cup of coffee has not kicked in
http://http://www.cisco.com/en/US/partner/docs/switches/datacenter/nexus5000/sw/configuration_limits/limits_421/Cisco_Nexus_5000_Series_Configuration_Limits_for_Cisco_NX_OS_Release_421_N1_1_and_421_N2_1_chapter1.html
As far as believe the only distance limitation would be the type of cable used. Either the distance limitation of the SMF SFP or the MMF SFP, or the CX ethernet cable which has reletively short distance spans.
Where is you here about this limitation?
And more importantly, what issues are you have towards the FEX? -
Nexus 5010/20 Vs Nexus 5548
Is there any difference between 5010/20 and 5548 in functionality for NAS?
I am using Nexus 5010 between UCS FIC and Array.
I am aware of the differences in port density, unified ports, L3 support etc etc.
Fundamentally what do I loose if I am just testing using 5010 compared to 5548.Hi Steve,
Thanks for the reply, this is the version currently running on the Nexus 5K:
Software
BIOS: version 1.5.0
loader: version N/A
kickstart: version 5.1(3)N2(1b)
system: version 5.1(3)N2(1b)
power-seq: Module 1: version v1.2
BIOS compile time: 11/30/10
kickstart image file is: bootflash:///n5000-uk9-kickstart.5.1.3.N2.1b.bin
kickstart compile time: 8/31/2012 17:00:00 [08/31/2012 17:30:27]
system image file is: bootflash:///n5000-uk9.5.1.3.N2.1b.bin
system compile time: 8/31/2012 17:00:00 [08/31/2012 18:29:34]
Regards,
-Michael -
Migration of Nexus 5010 to 5548
Is there document/procedure for replacing the 5010 Pair with 5548 pair? From what I understand the VPC's are compatible between a 50XX and 55XX hardware due to a change in the ASIC, is this correct? Has anyone completed this type of upgrade?
Thanks,
Joehi Isabel,
>> Jul 5, 2009, 9:14am PST
>> Both the Nexus 5000 and Nexus 7000 will add support for a
>> feature called Virtual Port Channels (VPC) which allows
>> the formation of multi-chassis ether channels like that
>> with VSS on the Catalyst 6500.
Nexus 7000 has had virtual Port Channel (vPC) since the release of NX-OS 4.2 around January this year.
see http://www.cisco.com/en/US/prod/collateral/switches/ps9441/ps9402/white_paper_c11-516396.html
you are correct that Nexus 5000 doesn't yet have this. N5K will gain vPC when NX-OS 4.2 is released on N5K in/on/around Q3 CY2009.
cheers,
lincoln. -
Nexus 5010 Won't Load System Image - Stuck at Boot Prompt
I have a 5010 that simply won't load any system image. Loads the kickstart image just fine, but once at the Switch(boot)# prompt just give me garbage when I enter "load bootflash:n5000-uk9.5.1.3.N2.1b.bin
Restarting system.
Loader Version pr-1.3
loader> dir
bootflash:
lost+found
n5000-uk9-kickstart.5.2.1.N1.1b.bin
n5000-uk9.5.2.1.N1.1b.bin
n5000-uk9-kickstart.5.1.3.N2.1b.bin
n5000-uk9.5.1.3.N2.1b.bin
loader> show version
Version is pr-1.3
loader> boot fb
Booting kickstart image: fb....
Error 15: File not found
loader> boot bootflash:n5000-uk9-kickstart.5.1.3.N2.1b.bin
Booting kickstart image: bootflash:n5000-uk9-kickstart.5.1.3.N2.1b.bin....
.................................Image verification OK
ÿserial 00:04: unable to assign resources
INIT: platform_type cmdline parameter not found. Asssuming Oregon.
I2C - Mezz absent
sprom_drv_init_platform: nuova_i2c_register_get_card_index
Starting Nexus5010 POST...
Executing Mod 1 1 SEEPROM Test......done
Executing Mod 1 1 GigE Port Test.......done
Executing Mod 1 1 Inband GigE Test.....done
Executing Mod 1 1 NVRAM Test....done
Executing Mod 1 1 PCIE Test...............................done
Mod 1 1 Post Completed Successfully
Mod 2 Post Completed Successfully
POST is completed
can't create lock file /var/lock/mtab~185: No such file or directory (use -n flag to override)
nohup: redirecting stderr to stdout
autoneg unmodified, ignoring
autoneg unmodified, ignoring
Checking all filesystems..... done.
Warning: switch is starting up with default configuration
Loading system software
No system image
INIT: Sending processes the TERM signal
INIT: Sending processes the KILL signal
Cisco Nexus Operating System (NX-OS) Software
TAC support: http://www.cisco.com/tac
Copyright (c) 2002-2012, Cisco Systems, Inc. All rights reserved.
The copyrights to certain works contained in this software are
owned by other third parties and used and distributed under
license. Certain components of this software are licensed under
the GNU General Public License (GPL) version 2.0 or the GNU
Lesser General Public License (LGPL) Version 2.1. A copy of each
such license is available at
http://www.opensource.org/licenses/gpl-2.0.php and
http://www.opensource.org/licenses/lgpl-2.1.php
switch(boot)# dir
16384 Jan 01 2005 20:57:47 lost+found/
34349568 Jan 10 2005 20:05:23 n5000-uk9-kickstart.5.1.3.N2.1b.bin
31642624 Jan 09 2005 04:23:49 n5000-uk9-kickstart.5.2.1.N1.1b.bin
172705188 Jan 10 2005 20:34:02 n5000-uk9.5.1.3.N2.1b.bin
173082673 Jan 09 2005 22:07:23 n5000-uk9.5.2.1.N1.1b.bin
Usage for bootflash: filesystem
0 bytes used
2147483647 bytes free
2147483647 bytes total
switch(boot)# load bootflash:n5000-uk9.5.1.3.N2.1b.bin
INIT: Sending processes the TERM signal
INIT: (boot)#
INIT: Sending processes the TERM signal
INIT: Sending processes the KILL signal
Cisco Nexus Operating System (NX-OS) Software
TAC support: http://www.cisco.com/tac
Copyright (c) 2002-2012, Cisco Systems, Inc. All rights reserved.
The copyrights to certain works contained in this software are
owned by other third parties and used and distributed under
license. Certain components of this software are licensed under
the GNU General Public License (GPL) version 2.0 or the GNU
Lesser General Public License (LGPL) Version 2.1. A copy of each
such license is available at
http://www.opensource.org/licenses/gpl-2.0.php and
http://www.opensource.org/licenses/lgpl-2.1.php
switch(boot)#
Any help greatly appreciated.Hi, I have the same problem as you.
Maybe you are looking for
-
I have restored my new iphone 5 but everytime i plug it back into iTunes i am asked if i want to set up a new phone or restore it. I have already set it up and tried to restore it again thinking this might help but i still keep getting the same messa
-
Hi Friends, We have planned to upgrade our SCCM 2012 SP1 infrastructure to SCCM 2012 R2 so we have setup test environment to test SQL database upgrade before doing same in production. But while testing SQL database upgrade on test machine, it is gett
-
Sound issues in games after updates
Hi all, I have a Quad w/ 2GB RAM, 250GB HDD and 7800GT. Just a couple of days ago, all the games I play worked fine (Rise of Nations, Rainbow Six III, Ghost Recon, America's Army etc. etc.). Now, when I load Ghost Recon, I get music on the menus, but
-
Domain Logon status - not authenticated
I am starting here. Win8.1 pro client. It is a domain client and fully goes through logon validation. Server 2012R2 AD On Domain client PC, active network panel responds as Private Network, FQDN mydomain.local (Unauthenticated) I can access all serve
-
Attributes of tax codes have been updated
Hi All, One of the users is getting this system message while using the print preview function. It doesn't stop the user from previewing the form, but still I would like to know the cause of this message. He is getting this message on delivery. No su