Nexus 5548 and err-vlans

Hi
I have configured some vituals VPC and a customer Nexus Switch.
But if run this commands:
sh int port-channel 8 status err-vlans
It returns 3 vlans. But i can't find what this means.
The vlan is working, and traffic is flowing though it.
Regards Kenneth Dalbjerg

Hi,
Is VPC configured correctly?  Has the port-channel been configured on both 5ks?
What is the output of "sh vpc and sh vpc incons?
Can you post the relevant configs from both 5ks?
Also, what is the output of sh port-cha summary
HTH

Similar Messages

  • Fabric with two Nexus-5548 and a brocade switch does not get fabric updates

    We have a fabric containing two Nexus 5548 and a Brocade 5000 switch in interop mode 2. When i make changes to the zoning, the first nexus (the fabric principal) and the brocade switch see the zone changes. The second Nexus switch does not see it. There are no error messages but  the change just can't be seen.  What can i do to find out, what goes wrong ?

    Ouch, deprecated is not the word i wanted to read
    We are using 5.1(3)N1(1a) on nexus-rz1-a
    and 6.0(2)N1(2) on nexus-rz2-a.
    The fabric can be seen :
    nexus-rz2-a# show fcs ie vsan 10
    IE List for VSAN: 10
    IE-WWN                   IE     Mgmt-Id  Mgmt-Addr (Switch-name)
    10:00:00:05:1e:90:57:27  S(Rem) 0xfffc01 10.88.133.110 (bc-san1)
    20:0a:00:2a:6a:72:ba:01  S(Loc) 0xfffc1c 10.88.133.105 (nexus-rz2-a)
    20:0a:54:7f:ee:7f:dc:01  S(Adj) 0xfffc0b 10.88.133.100 (nexus-rz1-a)
    [Total 3 IEs in Fabric]
    nexus-rz1-a# show fcs ie vsan 10
    IE List for VSAN: 10
    IE-WWN                   IE     Mgmt-Id  Mgmt-Addr (Switch-name)
    10:00:00:05:1e:90:57:27  S(Adj) 0xfffc01 10.88.133.110 (bc-san1)
    20:0a:00:2a:6a:72:ba:01  S(Adj) 0xfffc1c 10.88.133.105 (nexus-rz2-a)
    20:0a:54:7f:ee:7f:dc:01  S(Loc) 0xfffc0b 10.88.133.100 (nexus-rz1-a)
    [Total 3 IEs in Fabric]
    I try to distribute the zoneset this way:
    zoneset distribute vsan 10
    Zoneset distribution initiated. check zone status
    nexus-rz1-a# show zone status
    VSAN: 10 default-zone: deny distribute: full Interop: 2
        mode: basic merge-control: allow
        session: none
        hard-zoning: enabled broadcast: disabled
    Default zone:
        qos: none broadcast: disabled ronly: unsupported
    Full Zoning Database :
        DB size: 6291 bytes
        Zonesets:1  Zones:62 Aliases: 44
    Active Zoning Database :
        DB size: 10243 bytes
        Name: FABRIC1  Zonesets:1  Zones:60
    Status: Zoneset distribution completed at 08:06:00 UTC Dec  3 2013
    nexus-rz2-a# show zone status
    VSAN: 1 default-zone: deny distribute: active only Interop: default
        mode: basic merge-control: allow
        session: none
        hard-zoning: enabled broadcast: disabled
    Default zone:
        qos: none broadcast: disabled ronly: unsupported
    Full Zoning Database :
        DB size: 4 bytes
        Zonesets:0  Zones:0 Aliases: 0
    Active Zoning Database :
        Database Not Available
    Status:
    VSAN: 10 default-zone: deny distribute: full Interop: 2
        mode: basic merge-control: allow
        session: none
        hard-zoning: enabled broadcast: disabled
    Default zone:
        qos: none broadcast: disabled ronly: unsupported
    Full Zoning Database :
        DB size: 6291 bytes
        Zonesets:1  Zones:62 Aliases: 44
    Active Zoning Database :
        DB size: 10243 bytes
        Name: FABRIC1  Zonesets:1  Zones:60
    Status: Activation completed at 13:03:42 UTC Dec  2 2013

  • Nexus 5548 and Define static route to forward traffic to Catalyst 4500

    Dear Experts,
    Need your technical assistance for the Static routing in between Nexus 5548 and Catalyst 4500.
    Further I connected both Nexus 5548 with Catalyst 4500 as individual trunk ports because there is HSRP on Catalyst 4500. So I just took 1 port from each nexus 5548, make it trunk with the Core Switch (Also make trunk from each Switch each port). Change the speed on Nexus to 1000 because other side on Catalyst 4500 line card is 1G RJ45.
    *Here is the Config on Nexus 5548 to make port a Trunk:*
    N5548-A/ N5548-B
    Interface Ethernet1/3
    Switchport mode trunk
    Speed 1000
    Added the static route on both nexus for Core HSRP IP: *ip route 0.0.0.0/0 10.10.150.39 (Virtual HSRP IP )*
    But I could not able to ping from N5548 Console to core Switch IP of HSRP? Is there any further configuration to enable routing or ping?
    Pleas suggest

    Hello,
    Please see attached config for both Nexus 5548. I dont have Catalyst 4500 but below is simple config what I applied:
    Both Catalyst 4500
    interface gig 3/48
    switchport mode trunk
    switchport trunk encap dot1q
    On Nexus 5548 Port 1/3 is trunk
    Thanks,
    Jehan

  • Nexus 7k and native vlan 1

    Hi, is it recommended to use a native vlan other than 1 on the trunks connecting Nexus box's. It used to be that you should not use native vlan 1 on the trunks between switches. Is this not an issue anymore.
    Thanks

    Hi Chuck,
    It is recomended to use a different vlan other than vlan 1 as your default vlan.
    This is one of the best practices for secure the overall network.
    For eg.
    In a switch spoofing attack, an attacking host imitates a trunking  switch by speaking the tagging and trunking protocols (e.g. Multiple  VLAN Registration Protocol, IEEE 802.1Q, VLAN Trunking Protocol) used in  maintaining a VLAN. Traffic for multiple VLANs is then accessible to  the attacking host. 
    HTH,
    Aman

  • Nexus 5548 and vfc Interfaces - WHY?

    What is a vfc and why do we need to configure it? I find this extremely tedious.
    I  have a Dell blade CNA connected to a Dell M8024-k FCoE transit module,  which is then connected to a Cisco Nexus 5K. The Cisco 5K's FC port is  in NPIV mode and is connected to a Brocade 300 switch. An FC target is  connected to the B300.
    So, in configuring this set up, I see that, in the Cisco 5K, one has to map the CNA's Ethernet MAC-address to a vfc!
    Why  do I have to do this mapping? You dont have to do this with Brocade.  For example, in another lab setup, I have a Dell M8428-k FCF (FCoE)  switch, which is a Brocade ODM, and there is no such mapping necessary.  You bring up a CNA at will, the CNA executees a FIP FLOGI, gets an FPMA  from the FC fabric switch, and a construct is seamlessly built  between that CNA (or perhaps more correctly stated, the N-Port component  of that CNA) and a LUN. NO MANUAL MAPPING is necessary.
    Can  someone explain this Cisco vfc construct and why one has to engage in  this laborious task of mapping every CNA to a vfc? Just trying to  understand....perhaps I am missing something.
    Thank you

    Hello,
    Virtual Fiber Channel ( vfc ) interfaces are used to apply FC features in FCoE link.
    Check out the section " Cisco Nexus 5000 Series Virtual Fibre Channel Interfaces " in following link
    http://www.cisco.com/en/US/prod/collateral/switches/ps9441/ps9670/white_paper_c11-560403.html
    Additional guidelines on vfc configuration are  documented here
    http://www.cisco.com/en/US/partner/docs/switches/datacenter/nexus5000/sw/fcoe/513_n1_1/b_Cisco_n5k_fcoe_config_gd_re_513_n1_1_chapter_0100.html#con_1288652
    Padma

  • Vlan on Nexus 5548

    I have 2 Nexus 5548, and those are VPC members. If I create a new Vlan (vlan 90) on each switch, will there any impact on the Peer link? Like peer link goes down or link flap ? 
    Thanks & Regards, 
    Manu

    Hi Manu,
    Creating new Vlan on both switches wont get any impact.
    But be careful if you Vlan allow list on VPC peer link or VPC member link were you need to flow this new created vlan.  
    Br.
    Mohseen 

  • Configuring FET-10G-SR for NEXUS 5548/2248

    Hey everyone-
    I am a little newer with configuring switches and routers, and I have been asked to troubleshoot a FET-10G-SR in our NEXUS 5548 and NEXUS 2248.  I am aware that the ports need to be configured to except FET parts, and I have tried using the "switchport mode fex-fabric" command to configure the ports, but the command will not work for some reason. Can anyone help me with configurations step by step to have these parts work properly? Any help will be greatly appreciated. Thank you!
    Chris Hazell

    It should normally work unless the port is not the proper type of has a configuraiton applied that's incompatible.
    Can you provide the output for "show run int eth ___" and "show int eth___" (substituting your interface number for the "___") for the interface in question?
    Also, if it's the first fex you are adding, you must have enabled "feature fex" globally.

  • C220 M4 w/ VIC1225 and Nexus 5548

    I have four UCS C220 M4 servers that each have a VIC 1225 and are connected up to a Nexus 5548.  I have set them to trunk ports and have set the appropriate VLANs in ESX and the portgroups.  I can ping the gateway and other hosts on the network, but for some reason I can't ping any of the other C220 M4 servers that have a VIC1225.  All of the C220's can ping other devices on the network, but not each other.  Is there some setting I need to modify on the VIC or switch?  Currently the VIC is running as Classical Ethernet mode.

    There is no special configuration to make connectivity work in the rack servers, I assume these servers are in standalone mode and not integrated with UCSM.
    What L3 device is doing your Inter-Vlan routing? Is it the N5K these servers are connected to or there is another device doing this job?   If it is the N5K, are all the servers in the same network segment? I mean, is there a single SVI or multiple?  can your Nexus 5K ping each of the servers?
    -Kenny

  • FCoE using Brocade cards CNA1020 and Cisco Nexus 5548 switches

    All,
    I have the following configuration and problem that I am not sure how to fix:
    I  have three Dell R910 servers with 1TB of memory and each has two  brocade 1020 CNA cards dual port.  I am using distributed switches for  the VM network and a second distributed switch for VMotion.  I have two  of the 10G ports configured in each distributed switch using IP Hash.   The management network is configured using a standard switch with two 1G  ports.
    The  Nexus configuration is we have two nexus 5548 switch connected together  with a trunk.  We have two VPC's configured to each ESX hosts  consisting of two 10gig ports in each VPC with one port going to each  switch.  The VPC is configured for static LAG.
    What  I am seeing is that after a few hours the virtual machines will not be  accessible via network anymore.  So if you ping the VM it will not work  and if you get on the console of the VM then ping the gateway then  nothing as well but if you try to ping another virtual machine on the  same host on the same VLAN then it will work so traffic is going through  the ESX backplane.  If I reboot the ESX host then things will work  again for another few hours or so then the problem repeats.
    The version of vSphere I am using is ESXi4.1
    Please assist I am stuck.
    Thanks...

    Here is the link for Nexus and Brocade interoperability Matrix
    http://www.cisco.com/en/US/docs/switches/datacenter/mds9000/interoperability/matrix/Matrix7.html#wp313498
    usually this table would show those models those have been tested and verified
    However I do not see  Brocade 5300 listed in the table . It could be, interoperability may have not been tested by both vendors perticularly to 5300 type Model.

  • Nexus, configure sync and Interface VLAN

    We have a pair of Nexus 5548's. Not everything is dual-homed. For example, 
    only one of them has a 10-gig link to our main office (along with a 100 meg 
    link elsewhere). I'd like to set up a switch profile between these switches 
    so I can set up vPC's with our UCS fabric interconnects as well as a pair of 
    Fex Modules we have.
    As it stands, we have SVI's on each switch, with hsrp between them, so the 
    secondary switch takes over as gateway if the primary fails.
    Is it possible (and if so, best practice) after creating a switch profile, 
    and then going into configure sync mode to create SVI's (eg `interface vlan x`) 
    so that the SVI's are shared between the two switches, rather than creating 
    an SVI on each using hsrp in the event one of the switches fails?
    Also, again, can we leave some ports out of the dual switch profile, if not 
    everything is dual-homed?

    That is correct. It is that easy. Don't forget that te physical port has to be configured as a layer 2 port (switchport).
    You could create sub interfaces under the GigE interface if you were to configure that same physical interface as a layer 3 port (no switchport).
    Hope this helps,

  • FCoE with Cisco Nexus 5548 switches and VMware ESXi 4.1

    Can someone share with me what needs to be setup on the Cisco Nexus side to work with VMware in the following scenario?
    Two servers with two cards dual port FCoE cards with two ports connected to two Nexus 5548 switches that are clusterd together.  We want to team the ports together on the VMware side using IP Hash so what should be done on the cisco side for this to work? 
    Thanks...

    Andres,
    The Cisco Road Map for the 5010 and 5020 doesn't include extending the current total (12) FEX capabities.  The 5548 and 5596 will support more (16) per 55xxk, and with the 7K will support upto 32 FEX's.
    Documentation has been spotty on this subject, because the term 5k indicates that all 5000 series switches will support extended FEX's which is not the case only the 55xx will support more than 12 FEX.  Maybe in the future the terminology for the 5k series should be term 5000 series and 5500 series Nexus, there are several differences and advancements between the two series.

  • Prime Infrastructure 2.0 and Nexus 5548, SSH credentials fail

    Hi,
    I'm having problem getting the Prime Infrastructure 2.0 to login with SSH to a Nexus 5548 to do an inventory. I get "Wrong Telnet/SSH credentials". But when I use the same credentials from another SSH-client it works fine. I also tested to SSH from the console of the Prime-server and that also works fine.
    Any ideas???
    Regards,
    Stefan Lindkvist

    I have PI 2.0 working against Nexus 5k's in two different installations. See below for an example (click to enlarge).
    Have you put in an entry in both the login and enable fields (even though they are not separately required when logging in directly)?

  • Link FC between Nexus 5548 UP and Brocade 300

    Hello,
    I have got two Nexus 5548UP and fabric Brocade.
    I would like to connect my Nexus at my fabric Brocade.
    See the pdf file.
    Best regards,

    Its possible to have more links between npv and brocade but if you want to port channel them, please check first with brocade support if they allow F port channel trunking in their code. Not sure if FOS 6.2.2 supports it. From our side (cisco switch running npv) we should be able to do a port channel upto any NPIV switch provided the upstream switch supports it.
    https://supportforums.cisco.com/thread/2091664
    Thanks,
    Vinayak

  • Telephony Issues on Nexus 5548

    Dear Viewers,
    I have Nexus 5548 devices in one of my client data centers and i have one 3750 switch to which all of these Avaya voice servers connect.
    The 3750 switch was initially connected through a L2 Link to a 6509 catalyst switch and the telephony applications were working correctly.
    The problem arises when i move this 3750 layer 2 link to a Nexus 5548 (OS version 5.1(3)N1 switch. All telephony calls coming from the outside (External calls) are not working as required but the internal calls work as usual.
    What is odd is that when i migrate this L2 link back to the 6509 switch, all works as usual. This is just a layer 2 connection and i am wondering why this is not possible.
    The vlan is accepted on all relevant trunks. I also deactivated igmp snooping on this voice vlan on the Nexus 5548 thinking it would help but in vain.
    Any ideas and suggestions are welcome.
    regards.
    Alain

    This is my radius config......  on a 5K
    radius-server timeout 7
    radius-server host 10.28.42.20 key 7 "Password" auth-port 1645 acct-port 1646 authentication accounting
    radius-server host 10.28.42.21 key 7 "Password" auth-port 1645 acct-port 1646 authentication accounting
    aaa group server radius Radius-Servers
     server 10.28.42.20
     server 10.28.42.21
    aaa authentication login default group Radius-Servers
    ip radius source-interface Vlan1
    aaa authentication login default fallback error local
    And it is currently working. On the radius server i also had to do this to make the users admins once logged in:
    https://supportforums.cisco.com/document/137181/nexus-integration-admin-access-free-radius

  • Nexus 5548 not responding to snmp

    I've got a Nexus 5548 running 6.0(2)N2(3).  It does not use the mgmt interface or management vrf.  It's using a vlan interface for all my management access.
    I have a simple snmp config set up:
    snmp-server community mystring
    My SNMP server is directly connected (no firewalls, no acls).  I can ping my nexus from the SNMP host, but can't get SNMP replies.
    I've done an SNMP debug, nothing happens when I run an snmpwalk.  I also checked show snmp, and it's showing no SNMP input packets.  
    Could this have something to do with trying to use the management vrf?  Or something simple I'm missing?  
    Thanks

    Ha wow -- "sh run snmp" pointed me to the problem. There was a command:
    no snmp-server protocol enable
    That must be a default, I never entered that.  Anyway a 'snmp-server protocol enable' fixed it.  I should have caught that.  Although an hour with TAC also didn't notice it hehe.
    Thanks!

Maybe you are looking for

  • "Error Code -50" when moving macbook pro?

    Hello! I'm having an issue that I can't exactly find anywhere else. Starting in August or so, my hard drive started having issues with error code -50, almost always when I moved the computer suddenly (setting it on a table, standing up with it too qu

  • SG300-20 configure 1 ip pr port

    We got 1 customer that would like us to configure a system based on SG300-20 linked up with an SG300-10SFP using trafficshaping ingress and egress limited to 40mbit. This part of the case is solved using ingress/egress 40960 with an burtlimit a bith

  • ui:ContextMenuItem in MXML causes Error 1136: Incorrect number of arguments

    Hello, I'm trying to define a context menu declaratively like so: quote: <ui:ContextMenu id="editChartDataContextMenu"> <ui:customItems> <mx:Array> <ui:ContextMenuItem caption="Clear"/> </mx:Array> </ui:customItems> </ui:ContextMenu> However, the Fle

  • Opening Firefox 6.0 starts up to 8 Firefox windows

    When I click on the Firefox shortcut, it opens up to eight blank Firefox windows. If I click through them to close them all, then relaunch Firefox 6.0 it opens one less window (i.e. 7). It would appear that this behavior continues, with the window co

  • Video clips not working when opened through video ...

    hello Its been just a week that I brought my nokia e63 but it is giving me some problems  1. the video clips get stuck after some time, then it again pauses and plays it continues,,: when opened through video clips in gallery,, whereas it works fine