Nexus 5596 to join Brocade fabric
Hi all, I tried to search but didn't find a "real" answer, it is not clear if it is possible or not...
Problem: I always worked with homogeneous Brocade fabrics. Some days ago my company asked me if it is possible to add a Nexus 5596UB to an existing (6 switches) production Brocade fabric. I underlined production as we should not interrupt SAN traffic on joining the fabric nor we should reboot and/or reconfigure existing switches.
I found a lot of info about "interoperability mode" on MDS switches but nothing on Nexus.
Can someone help me? Thanks.
According to the datasheet
http://www.cisco.com/c/en/us/products/collateral/switches/nexus-5000-series-switches/data_sheet_c78-618603.html
Native interop 1,2,3 and 4 is supported !
Therefore you are ok, and have a TAC supported configuration.
Fibre Channel and FCoE Features (Requires Storage Services License)
● T11 standards-compliant FCoE (FC-BB-5)
● T11 FCoE Initialization Protocol (FIP) (FC-BB-5)
● Any 10 Gigabit Ethernet port configurable as FCoE
● SAN administration separate from LAN administration
● FCP
● Fibre Channel forwarding (FCF)
● Fibre Channel standard port types: E, F, and NP
● Fibre Channel enhanced port types: VE, TE, and VF
● F-port trunking
● F-port channeling
● Direct attachment of FCoE and Fibre Channel targets
● Up to 240 buffer credits per native Fibre Channel port
● Up to 32 VSANs per switch
● Fibre Channel (SAN) PortChannel
● Native Interop Mode 1
● Native Interop Mode 2
● Native Interop Mode 3
● Native Interop Mode 4
● VSAN trunking
● Fabric Device Management Interface (FDMI)
● Fibre Channel ID (FCID) persistence
● Distributed device alias services
● In-order delivery
● Port tracking
● Cisco N-Port Virtualization (NPV) technology
● N-port identifier virtualization (NPIV)
● Fabric services: Name server, registered state change notification (RSCN), login services, and name-server zoning
● Per-VSAN fabric services
● Cisco Fabric Services
● Diffie-Hellman Challenge Handshake Authentication Protocol (DH-CHAP) and Fibre Channel Security Protocol (FC-SP)
● Distributed device alias services
● Host-to-switch and switch-to-switch FC-SP authentication
● Fabric Shortest Path First (FSPF)
● Fabric binding for Fibre Channel
● Standard zoning
● Port security
● Domain and port
● Enhanced zoning
● SAN PortChannels
● Cisco Fabric Analyzer
● Fibre Channel traceroute
● Fibre Channel ping
● Fibre Channel debugging
● Cisco Fabric Manager support
● Storage Management Initiative Specification (SMI-S)
● Boot from SAN over VPC/EVPC
Similar Messages
-
Nexus 5596 connection to Brocade 5100
Hi All
I would like to connect the Nexus 5500 to a Brocade 5100 FC switch. I was hoping is somebody has done this before and can provide sample configuration. The Brocade connects to the SAN. The Nexus 5500 will connect to a server with a CNA.
Any help or direction would be much appreciated.
Regards
AhmedHi All
I would like to connect the Nexus 5500 to a Brocade 5100 FC switch. I was hoping is somebody has done this before and can provide sample configuration. The Brocade connects to the SAN. The Nexus 5500 will connect to a server with a CNA.
Any help or direction would be much appreciated.
Regards
Ahmed -
Nexus 5596 Layer 2 Switching Fabric Statistics
Hi everybody
Basic question, I would like to know how much traffic the is switch forwarding in Layer 2.
In other words, a simple set of counters that in an aggregated way includes statistics from all interfaces.
Any show commands or SNMP MIBs are welcomed.
Thanks in advance• Cisco Nexus 5548P and 5548UP: Layer 2 hardware forwarding at 960 Gbps or 714.24 mpps; Layer 3 performance of up to 160 Gbps or 240mpps
• Cisco Nexus 5596UP and 5596T: Layer 2 hardware forwarding at 1920 Gbps or 1428 mpps; Layer 3 performance of up to 160 Gbps or 240mpps -
Fabric with two Nexus-5548 and a brocade switch does not get fabric updates
We have a fabric containing two Nexus 5548 and a Brocade 5000 switch in interop mode 2. When i make changes to the zoning, the first nexus (the fabric principal) and the brocade switch see the zone changes. The second Nexus switch does not see it. There are no error messages but the change just can't be seen. What can i do to find out, what goes wrong ?
Ouch, deprecated is not the word i wanted to read
We are using 5.1(3)N1(1a) on nexus-rz1-a
and 6.0(2)N1(2) on nexus-rz2-a.
The fabric can be seen :
nexus-rz2-a# show fcs ie vsan 10
IE List for VSAN: 10
IE-WWN IE Mgmt-Id Mgmt-Addr (Switch-name)
10:00:00:05:1e:90:57:27 S(Rem) 0xfffc01 10.88.133.110 (bc-san1)
20:0a:00:2a:6a:72:ba:01 S(Loc) 0xfffc1c 10.88.133.105 (nexus-rz2-a)
20:0a:54:7f:ee:7f:dc:01 S(Adj) 0xfffc0b 10.88.133.100 (nexus-rz1-a)
[Total 3 IEs in Fabric]
nexus-rz1-a# show fcs ie vsan 10
IE List for VSAN: 10
IE-WWN IE Mgmt-Id Mgmt-Addr (Switch-name)
10:00:00:05:1e:90:57:27 S(Adj) 0xfffc01 10.88.133.110 (bc-san1)
20:0a:00:2a:6a:72:ba:01 S(Adj) 0xfffc1c 10.88.133.105 (nexus-rz2-a)
20:0a:54:7f:ee:7f:dc:01 S(Loc) 0xfffc0b 10.88.133.100 (nexus-rz1-a)
[Total 3 IEs in Fabric]
I try to distribute the zoneset this way:
zoneset distribute vsan 10
Zoneset distribution initiated. check zone status
nexus-rz1-a# show zone status
VSAN: 10 default-zone: deny distribute: full Interop: 2
mode: basic merge-control: allow
session: none
hard-zoning: enabled broadcast: disabled
Default zone:
qos: none broadcast: disabled ronly: unsupported
Full Zoning Database :
DB size: 6291 bytes
Zonesets:1 Zones:62 Aliases: 44
Active Zoning Database :
DB size: 10243 bytes
Name: FABRIC1 Zonesets:1 Zones:60
Status: Zoneset distribution completed at 08:06:00 UTC Dec 3 2013
nexus-rz2-a# show zone status
VSAN: 1 default-zone: deny distribute: active only Interop: default
mode: basic merge-control: allow
session: none
hard-zoning: enabled broadcast: disabled
Default zone:
qos: none broadcast: disabled ronly: unsupported
Full Zoning Database :
DB size: 4 bytes
Zonesets:0 Zones:0 Aliases: 0
Active Zoning Database :
Database Not Available
Status:
VSAN: 10 default-zone: deny distribute: full Interop: 2
mode: basic merge-control: allow
session: none
hard-zoning: enabled broadcast: disabled
Default zone:
qos: none broadcast: disabled ronly: unsupported
Full Zoning Database :
DB size: 6291 bytes
Zonesets:1 Zones:62 Aliases: 44
Active Zoning Database :
DB size: 10243 bytes
Name: FABRIC1 Zonesets:1 Zones:60
Status: Activation completed at 13:03:42 UTC Dec 2 2013 -
What is the best way to migrate zoning from an MDS9216i to a Nexus 5596?
I am migrating from a MDS9216i to a Nexus 5596. We have dual paths, so I can migrate one leg at a time and the full function for these switches is fiber channel attached storage.
What is the best way to migrate the zoning information? I have been told I can ISL the new and old switch together and then push the zoning to the new switch. Is that better than just cutting and pasting the zoning information to the new switch?
Also, I have to move four Brocade M4424 switches to the new switches - they are currently attached via interop mode 1, but will now be attached using NPIV. Has anyone done this before, and did you have any issues?
Any help or advice would be appreciated. Thanks!Use an ethernet cable to connect the two computers, and set up file sharing. After that copying files from one computer to the other is exactly like copying from one hard drive to another:
http://docs.info.apple.com/article.html?artnum=106658 -
Hello Friends,
Just want to save your precious time & effort, while doing Nexus 5596 upgrades so wanted to share some useful info which you can have a look prior to your upgrades of Cisco Nexus 5596 device.
I recently ran into trouble when upgarding one of datacenter switch Nexus 5596 does not boots up and after investigation from Cisco TAC it comes out to be Bug documented below.
https://tools.cisco.com/bugsearch/bug/CSCun66310/?reffering_site=dumpcr
My Upgrade path of device was : 5.1(3)N1(1) to 6.0(2)N2(5).
Since this upgarde involves upgrade of Bios and Power sequensor, I was having some doubts to get this succesfully upgraded, But there was more twist involved in this upgrade which I came to know after contacting Cisco TAC for my died Nexus 5596 device and got info that if you have below impacted version in your Nexus 5596 device and you are planning to do Upgrade, then you migh RUN into this serious BUG aftre which device won't come up at all and only Option left is to replace with RMA device.
PID Impacted Hardware versions Updated Versions
UCS-FI-6296UP 1.0 1.1
N5K-C5596UP 1.0 1.1
N5K-C5596T 1.1 1.2
You can check hardware version using below command from your device.
5596# show sprom sup | inc H/W
H/W Version : 1.1
So please be carefull when planning your Nexus 5596 upgrade and verify above things as this Bug is not present anywhere in Upgrade docuemntations unfortunately.
Hope this will help and save someone's precious Time.Today "upgraded" our switch (N5k-C5596UP) to from 5.1(2)N1 to 7.0(5) and after reboot no life from the switch either. Even no console response. show sprom sup | inc H/W shows 1:0.
Only thing we could do is RMA the switch. So what must I do with these switches? Have still to do 3 of them. -
Maximum number of interfaces in Port Channel on Nexus 5596
Let me preface this by saying I am not a network expert....
I noticed that our customer had configured a port channel on their Nexus 5596 comprised of 16 interfaces. I thought the maximum number of interfaces in a port channel was 8 interfaces? I see in the Nexus 7000 documentation that if you configure 16 interfaces, the remaining 8 will be in "hot standby." Is this the same behavior on the Nexus 5000 series?
Thank you.Same behavior on the 5500 series and other Cisco switches like 3750, 3850 , etc..
HTH -
Nexus 5596 Ethernet Port Configuration
I have a Cisco Nexus 5596 with 48 Ethernet Ports (two of which are now configured for Fibre Channel). It has a FEX attached to it as well.
I was able to configure ANY Ethernet port with the typical interface commands when in interface configuration mode. However, I can now only configure existing and new Port Channel interfaces, FEX ports and standard Ethernet ports that have never been configured before.
If I try to configure an Ethernet interface that was configured in the past, I only seem to have access to global interface commands when in interface configuration mode. I can set spanning-tree, duplex, speed or any other interface parameters. The CLI acts like I'm not in interface config mode, but the prompt shows that I am.
Anyone else seen such a thing? I am logged in as admin.Hi Mark
I suspect the interface in question is configured to be in a channel. Once an ethernet interface is configured to be in a port-channel. most interface commands need to be configured under the port-channel interface
Thanks
-Prashanth -
Question about Nexus 5596 log.
Dear Mister
When I connect toward Nexus 5596, using ipv4 telnet, send the next message:
NITE3# 2013 May 9 18:32:53 NITE3 %LOCAL7-4-SYSTEM_MSG: service telnet, IPV6_ADDRFORM - dcos-xinetd[3193]
What is the reason for this?
Could be a bug?
Best RegardsHi,
If you want to view the changes made to any an order than open that order and click on EXTRAS--> CHANGE DOCUMENTS in the main menu.
Also if u want to see the changes made it the status u can refer the table CRM_JCDS.
Regards,
PePe -
Nexus 5596 Licensing - filename exceeds 30 characters
Hi,
I'm trying to licensing two Nexus 5596 (Evaluated License), when i'm enter the "install license bootflash:LICENSE.lic" the Nexus reflect this error:
"Installing license failed: Invalid filename size, filename exceeds 30 characters".
After i changed the name the Nexus reflect this error:
"Installing license failed: Invalid/Corrupt license file"
I tried to clear the license from one switch and now i'm cannot reinstall the license.
In the mail that cisco sent to me with the license they wrote that do not change the filename.
Thanks in advance,
Nadav Katz.Hi Eric,
I received the Nexus switches with corrupted license.
The license team of cisco was generate a new license and send it to me.
Regareds,
Nadav. -
Nexus 5596 switch-profile synchronization problem
hi
I can't synchronize switch-profile
System version: 5.1(3)N1(1)
Sync-status: Not yet merged
Merge Flags: pending_merge:0 rcv_merge:1 pending_validate:1
Status: Verify Failure
Error(s):
Following commands failed parsing: If the error is 'Command Parsing Failed', please check if some conditional feature(s) needs to be enabled
switchport mode trunk (Command Parsing Failed)
how to find the source of the problem ?Hello Pawel
Can you attach following from both Nexus 5596 switches in question
term length 0
show version
show run
show tech-support port-profile -
Nexus 5596 FC-Port Link-Events
Hi all,
int the last 3 weeks,
almost every day , we have a series of events in the connection between one Nexus 5596 and one of our servers. The connection is in FC (4G).
I need help to understand the output of the following command to troubleshoot what could be happening.
Sw-cpd-mm-n5k-2# show hardware internal fc-mac 3 port 14 link-event
MMDDYY HHMMSS usecs Event Current State
- - LINK_ACTIVE
100113 020845 773895 (0001) E_LINK_IDLE LINK_LRR_RX
100113 020845 765016 (0000) E_LINK_LRR LINK_LR_TX
100113 020845 763545 (61CB28) E_LINK_LINK_RESET LINK_ACTIVE
Sw-cpd-mm-n5k-2# show hardware internal fc-mac 3 port 14 port-event
MMDDYY HHMMSS usecs Event Current State
- - IPS_LINK_UP
100113 020845 775908 (0000) E_IPS_LINK_INIT_SUC IPS_LINK_UP
100113 020845 775907 (0000) E_IPS_IDLE IPS_LINK_UP
100113 020845 770040 (0001) E_IPS_LRR IPS_LINK_UP
100113 020845 763562 (61CB28) E_IPS_CREDIT_LOSS IPS_LINK_UP
Looking at the output I don't know who generates "E_LINK_LINK_RESET" , Nexus switch or server?
Thanks in advance!Hi,
I know it is a little bit late, but hope it can still be of use...
According to the log output, The switch detects a Credit Loss condition
00113 020845 763562 (61CB28) E_IPS_CREDIT_LOSS IPS_LINK_UP
and to recover from it, the switch resets the link by sending a LR to the server
100113 020845 763545 (61CB28) E_LINK_LINK_RESET LINK_ACTIVE
the server replies with a LRR, IDLE, etc.
100113 020845 765016 (0000) E_LINK_LRR LINK_LR_TX
Kind rgds,
Felipon -
Nexus 5596 and QOS config guide
Hi,
I need to implement qos on a nexus device for a client
Basically what I am trying to implement is this but on the nexus
Policy Map Enhanced_QoS_Customer_Out
Description: Enhanced QoS customers outbound Percentages
Class Cust_VoIP_Out
priority 30 (%)
Class Cust_Gold_Out
bandwidth 30 (%)
Class Cust_Silver_Out
bandwidth 13 (%)
Class Cust_Bronze_Out
bandwidth 2 (%)
Policy Map Ethernet_QoS_Customer_Out_200Mb
Class class-default
Average Rate Traffic Shaping
cir 200000000 (bps)
service-policy Enhanced_QoS_Customer_Out
Is this possible on the nexus 5596?
I havent found much information around shaping.. Please advise if the above policy is achelievable on the nexus and if not what does the nexus support?
regards,Hi,
I don't think the 5500 support shaping since it is mostly a layer-2 device. Here is the config guide for QOS.
http://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus5000/sw/configuration/guide/cli/CLIConfigurationGuide/QoS.html
HTH -
Trunking nexus 5596 and netapp or exsi issue
hi
i have 2 issues with trunking between nexus 5596 and a esxi server .....can not get the servers to ping out
and the netapp connected to the same 5596 cannot ping.
if the server is a access port it works fine.
is there any tricks that are required to be configured on the nexus to make this work.Make sure we are actually tagging for those vlans on the host (Netapp/ESXi). If we are not, then this would explain why it works in access mode on the switch.
-
We have a pair of Nexus 5596 switches, that each have a 1 gigabit conection to ISP CE switches (ME3400).
Switch 1 has a fibre connection using GLC-SX-MM with the following information...
sh int e1/48 trans
Ethernet1/48
transceiver is present
type is SFP-1000BASE-SX
name is CISCO-AVAGO
part number is SFBR-5766PZ-CS2
revision is
serial number is AGA1549L2BE
nominal bitrate is 1300 MBit/sec
cisco id is --
cisco extended id number is 4
I cannot get the port to come up on switch 2, transceiver info...
sh int e1/48 trans
Ethernet1/48
transceiver is present
type is SFP-1000BASE-SX
name is CISCO-AVAGO
part number is SFBR-5766PZ-CS2
revision is
serial number is AGA1549L2BE
nominal bitrate is 1300 MBit/sec
cisco id is --
cisco extended id number is 4
The port is up on the ISP switch, but down on the N5K...
Ethernet1/48 is down (Link not connected)
Hardware: 1000/10000 Ethernet, address: 547f.ee41.e337 (bia 547f.ee41.e337)
Description: Intech WAN ME3400-1 (BT)
MTU 1500 bytes, BW 1000000 Kbit, DLY 10 usec
reliability 255/255, txload 255/255, rxload 255/255
Encapsulation ARPA
Port mode is trunk
full-duplex, 1000 Mb/s, media type is 10G
Beacon is turned off
Input flow-control is off, output flow-control is off
Rate mode is dedicated
Switchport monitor is off
EtherType is 0x8100
Last link flapped 00:31:00
Last clearing of "show interface" counters 00:00:47
30 seconds input rate 0 bits/sec, 0 packets/sec
30 seconds output rate 0 bits/sec, 0 packets/sec
Load-Interval #2: 5 minute (300 seconds)
input rate 242.30 Gbps, 163.37 Mpps; output rate 63.30 Gbps, 231.54 Mpps
RX
17828772964 unicast packets 2506759 multicast packets 991 broadcast packets
17831280714 input packets 3305852407174 bytes
897530002 jumbo packets 0 storm suppression bytes
20 runts 0 giants 0 CRC 0 no buffer
20 input error 0 short frame 0 overrun 0 underrun 0 ignored
0 watchdog 0 bad etype drop 0 bad proto drop 0 if down drop
0 input with dribble 0 input discard Ethernet1/48 is down (Link not connected)
Hardware: 1000/10000 Ethernet, address: 547f.ee41.e337 (bia 547f.ee41.e337)
Description: Intech WAN ME3400-1 (BT)
MTU 1500 bytes, BW 1000000 Kbit, DLY 10 usec
reliability 255/255, txload 255/255, rxload 255/255
Encapsulation ARPA
Port mode is trunk
full-duplex, 1000 Mb/s, media type is 10G
Beacon is turned off
Input flow-control is off, output flow-control is off
Rate mode is dedicated
Switchport monitor is off
EtherType is 0x8100
Last link flapped 00:31:00
Last clearing of "show interface" counters 00:00:47
30 seconds input rate 0 bits/sec, 0 packets/sec
30 seconds output rate 0 bits/sec, 0 packets/sec
Load-Interval #2: 5 minute (300 seconds)
input rate 242.30 Gbps, 163.37 Mpps; output rate 63.30 Gbps, 231.54 Mpps
RX
17828772964 unicast packets 2506759 multicast packets 991 broadcast packets
17831280714 input packets 3305852407174 bytes
897530002 jumbo packets 0 storm suppression bytes
20 runts 0 giants 0 CRC 0 no buffer
20 input error 0 short frame 0 overrun 0 underrun 0 ignored
0 watchdog 0 bad etype drop 0 bad proto drop 0 if down drop
0 input with dribble 0 input discard
I have tested the SFP's in use on a pair of 2960's & they work fine!
If i replace the SFP's for copper, then they work fine also.
Does anyone know of any incompatibility issue with this SFP?
Thanks
ColinDid you try a different port such as e1/1? Sounds like a bug to me
http://www.cisco.com/en/US/prod/collateral/switches/ps9441/ps9670/data_sheet_c78-618603.html
Table 2.
Cisco Nexus 5500 Platform Transceiver Support Matrix
Maybe you are looking for
-
[Solved] Random freezes on a Toshiba Qosmio X505-Q888
Hi guys, My laptop has been freezing randomly, about once per day, during the last 2 or 3 weeks. The system freezes completely, i.e. the display freezes, I cannot move the mouse, I cannot use the keyboard, the CAPS LOCK light starts blinking, and if
-
I just got an HP Stream 8 tablet with Windows on it. I have a Mac desktop running 10.6.8. I set up Home Sharing by making sure both had the same version of iTunes and I authorized the new tablet (desktop already was). (I haven't exceeded the numbe
-
Regarding datasource in weblogic server
Hi All, while creating datasource i am getting the following error An error occurred during activation of changes, please see the log for details. weblogic.application.ModuleException: weblogic.common.ResourceException: Could not create pool connecti
-
There are 4 Mac's in my house and I'd like to back up all of them to a time capsule, i know it is possible to do this. however i would also like to be able to dump files like; music, pictures, and documents onto the time capsule so that the others ma
-
HI all I have a database block with some text items i have a button on my form on the button i have an Update statement Upon entering the values on the form i click the button the update statement is triggered on some condition (in this case i dont w