Nexus 7000 supervisor replacement

     I'm trying to get my head around how to replace a supervisor module on a nexus 7000 with a single supervisor.  The setup has the default vdc and one other defined.  So if a sup  was faulty  what is the best way to handle this? I have the default vdc config and the other vdc on a tftpboot server. Whats the easiest  and fastest way to hand this .  In the default vdc add address    and copy  the default vdc config and then when that's in copy the other vdc config file.    Just used to IOS where you normally had a single file and you got the box on the air enough to copy the config file into startup and reloaded .  Hope this makes sense.   Tried to read some  of the docs but it's still not clear what exactly needs to be done.   Thanks for any help...

That makes sense.
1. Restore the default VDC config.
2. Create your second VDC.
3. Restore the second VDC config.
Don't forget to have a backup of any license files that you may have purchased, for example MPLS.

Similar Messages

  • Nexus 7000 Supervisor Management Port

    Hi,
    I have a deployment with 2 x Nexus 7009. Both N7K's have dual supervisor modules.
    Each Supervisor Module is connected to alternate management switches.
    Supervisor 1 is connected to Management Switch 1
    Supervisor 2 is connected to Management Switch 2
    In the event of a failure of Management Switch 1, access to Supervisor 1 is lost and in turn all access to the N7K.
    Is there any method of achieving connectivity to the Active Supervisor (1) when this scenario occurs.Can connectivity be achieved via the Standby Supervisor (other than making the Standby Supervisor the Active Supervisor).
    Thanks,
    Colm

    That is the correct behavior.  As long as the primary sup is up, you will see the mgmt0 for the primary Sup up.  The second you fail over to the stand-by sup, the mgmt0 for that sup will come up and the old primary will go down.  So, it is only one mgmt0 is up at a time.
    Make sure both mgmt0 interfaces are in the same vlan and also port fast is turned on so the mgmt ports comes up as soon as possible.
    HTH

  • Using SNMP to monitor Nexus 7000 Series Supervisor Module

    Hello,
    I got a Nexus 7000 supervisor module recently, I met a SNMP problem for this module
    I would like to know which specific OIDs to use to monitor the following using SNMP on a Nexus 7000 supervisor module:
    - Port status
    - CPU total utilization
    - Power Supply status
    - Chassis Fan status
    etc.
    The Nexus is quite different from other Cisco devices - any help will be appreciated!

    hope help,  and 
    port status OID is ifOperStatus
    CPU total utilization OID is 1.3.6.1.4.1.9.9.109.1.1.1.1.6.1
    [root@NET-MONITOR-1 ~]# 
    [root@NET-MONITOR-1 ~]# snmpwalk -On -v 2c -c 360buy 172.17.0.253 ifDescr.83886080
    .1.3.6.1.2.1.2.2.1.2.83886080 = STRING: mgmt0
    [root@NET-MONITOR-1 ~]# 
    [root@NET-MONITOR-1 ~]# snmpwalk -On -v 2c -c 360buy 172.17.0.253 ifOperStatus.83886080
    .1.3.6.1.2.1.2.2.1.8.83886080 = INTEGER: up(1)
    [root@NET-MONITOR-1 ~]# 
    [root@NET-MONITOR-1 ~]# snmpwalk -On -v 2c -c 360buy 172.17.0.253 1.3.6.1.4.1.9.9.109.1.1.1.1.6.1
    .1.3.6.1.4.1.9.9.109.1.1.1.1.6.1 = Gauge32: 21
    [root@NET-MONITOR-1 ~]#

  • Connecting IBM B22 FEXes to Nexus 7000

    Hello everybody,
    Could someone give an definite answer, better to based on personal experience - is it possible to attach B22 FEX going to the IBM chassis to Nexus 7000 via F2 series 48-port 10G card?
    NXOS is currently running 6.1.5a but we plan to upgrade to 6.2.8 or 6.2.12 once we get new 4GB DIMMs for SUP1 modules.
    Thanks.

    In my case, I was getting this error on a interface of a Nexus C6001 with the FET-10G transceiver.  I was able to clear it up by temorarily replacing and configuring a slower GLC-T which worked as expected.  I then removed all the settings an got the FET-10G to link.

  • Nexus 7000-Error Message

    Hi
    We are having 2 nexus switches configured in the network as core with HSRP configured between them..The access switches are connected withdual 10G links to both core switches with VPC configured in Nexus..In both core switches 10G module is used for uplink termination..In one of the core switch for this 10 G module we get the follwoing error
    Module-1 reported minor temperature alarm. Sensor=20 Temperature=101 MinThreshold=100 2011 Dec 22 08:10:19 CORE-SEC %PLATFORM-2-MOD_TEMPOK:
    Module-1 recovered from minor temperature alarm. Sensor=20 Temperature=99 MinThreshold=100 even though the room temprature is 23 Degree still we get this error wherein as per the nexus documenation allowed room temparature is 0-40 Degree (Operating temperature: 32º to 104ºF (0º to 40ºC) `
    show module`
    Mod  Ports  Module-Type                      Model                            Status
    1    8      10 Gbps Ethernet XL Module      N7K-M108X2-12L        ok
    2    32    1/10 Gbps Ethernet Module        N7K-F132XP-15          ok
    3    48    10/100/1000 Mbps Ethernet XL Mod N7K-M148GT-11L    ok
    5    0      Supervisor module-1X            N7K-SUP1                      active *
    As per the nexus module documentation for module1 the allwed temparature is 0-40degree wherein the actual room temparatue is 23degree..below is the exception message for module1
    exception information --- exception instance 1 ----
    Module Slot Number: 1
    Device Id         : 49
    Device Name       : Temperature-sensor
    Device Errorcode : 0xc3114203
    Device ID         : 49 (0x31)
    Device Instance   : 20 (0x14)
    Dev Type (HW/SW) : 02 (0x02)
    ErrNum (devInfo) : 03 (0x03)
    System Errorcode : 0x4038001e Module recovered from minor temperature alarm
    Error Type       : Minor error
    PhyPortLayer     :
    Port(s) Affected :
    DSAP             : 39 (0x27)
    UUID             : 24 (0x18
    Same module exists in second Nexus 7000 which is in same datacenter but not getting this alarm..
    can anyone please suggest on the same..Software details are as below
    Software
      BIOS:      version 3.22.0
    kickstart: version 5.1(3)
      system:    version 5.1(3)
      BIOS compile time:       02/20/10
      kickstart image file is: bootflash:///n7000-s1-kickstart.5.1.3.bin
      kickstart compile time:  12/25/2020 12:00:00 [03/11/2011 07:42:56]
      system image file is:    bootflash:///n7000-s1-dk9.5.1.3.bin
      system compile time:     1/21/2011 19:00:00 [03/11/2011 08:37:35]

    Hi Sameer
    Temperature alarm means that one particular sensor on the linecard warms up to 101 degree.
    This can be caused by damaged sensor or problems with cooling in that particular part of chassis.
    You can check temperature on the module using following command:
    show environment temperature module 1
    Tru to move the module to another slot. If the issue reoccure - open a TAC case.
    HTH,
    Alex

  • Connecting Cisco ASA TenGig to Nexus 7000

    I am attempting to connect an ASA 5585 TenGig to a Nexus 7000 F2 TenGig port. 
    I am seeing the error message Transceiver validation failed when I insert the SFP into the port.  I know that the error is removed when I enter the command switchport mode fex-fabric, and have tried the configuration, but am unable to get the link to come up.at either end. I am also aware that LACP is not supported when switchport mode fex-fabric is configured. 
    ASA is in multiple context mode with portchannel interfaces allocated to the relevant ASA context.  Anyone know if I am overlooking something?  Anyone run into this issue before?
    Nexus 7000:
    Eth1/1       1       eth  access down    Transceiver validation fa  auto(D) 2
    Eth1/2       1       eth  access down    Transceiver validation fa  auto(D) 2
    interface Ethernet1/1
      switchport mode trunk
      switchport trunk allowed vlan 1-10
      channel-group 2 mode active
      no shutdown
    interface Ethernet1/2
      switchport mode trunk
      switchport trunk allowed vlan 2-10
      channel-group 2 mode active
      no shutdown
    interface port-channel2
      switchport mode trunk
      switchport trunk allowed vlan 2-10
    ASA5585:
    interface TenGigabitEthernet0/6
    channel-group 2 mode active
    interface TenGigabitEthernet0/7
    channel-group 2 mode active
    interface Port-channel2
    interface Port-channel2.2
    vlan 2
    interface Port-channel2.3
    vlan 3
    context inside
      allocate-interface Port-channel2.1
      allocate-interface Port-channel2.2
      config-url disk0:/inside.cfg

    In my case, I was getting this error on a interface of a Nexus C6001 with the FET-10G transceiver.  I was able to clear it up by temorarily replacing and configuring a slower GLC-T which worked as expected.  I then removed all the settings an got the FET-10G to link.

  • Nexus 7000 Platform Logging

    Hello,
    We recently had a power supply failure in one of our Nexus 7000s, and I noticed that the syslog for the Platform is only present in the default VDC, and not in any of the other VDCs syslogs. Is this by design, or is there a logging level I can turn up in another VDC to capture this log? Thanks for any input
    syslog from default VDC -
    2013 Mar 18 23:10:34  %PLATFORM-2-PS_CAPACITY_CHANGE: Power supply PS3 changed i
    ts capacity. possibly due to power cable removal/insertion (Serial number xxxxxxxx)
    nothing in the VDC where I would like to get the logging
    default VDC logging level -
    xxx7K02# show log level platform
    Facility        Default Severity        Current Session Severity
    platform                5                       5
    0(emergencies)          1(alerts)       2(critical)
    3(errors)               4(warnings)     5(notifications)
    6(information)          7(debugging)
    xxx7K02#
    loggging from the specific VDC where we have management tools.
    xxx-LOW# show log level platform
    Facility        Default Severity        Current Session Severity
    platform                5                       5
    0(emergencies)          1(alerts)       2(critical)
    3(errors)               4(warnings)     5(notifications)
    6(information)          7(debugging)
    xxx-LOW#

    Hello Carl,
    What version of code are you running on your Nexus 7k?
    The expected behavior is:
    "When a hardware issue occurs, syslog messages are sent to all VDCs."
    http://www.cisco.com/en/US/docs/switches/datacenter/sw/nx-os/virtual_device_context/configuration/guide/vdc_mgmt.html#wp1170241
    Dave

  • Dell Servers with Nexus 7000 + Nexus 2000 extenders

    << Original post by smunzani. Answered by Robert. Moving from Document section to Discussions>>
    Team,
    I would like to use some of the existing Dell Servers for new network design of Nexus 7000 + Nexus 2000 extenders. What are my options for FEC to the hosts? All references of M81KR I found on CCO are related to UCS product only.
    What's best option for following setup?
    N7K(Aggregation Layer) -- N2K(Extenders) -- Dell servers
    Need 10G to the servers due to dense population of the VMs. The customer is not up for dumping recently purchased dell boxes in favor of UCS. Customer VMware license is Enterprise Edition.
    Thanks in advance.

    To answer your question, the M81KR-VIC is a Mezz card for UCS blades only.  For Cisco rack there is a PCIe version which is called the P81.  These are both made for Cisco servers only due to the integration with server management and virtual interface functionality.
    http://www.cisco.com/en/US/prod/collateral/ps10265/ps10493/data_sheet_c78-558230.html
    More information on it here:
    Regards,
    Robert

  • Ask the Expert: Basic Introduction and Troubleshooting on Cisco Nexus 7000 NX-OS Virtual Device Context

    With Vignesh R. P.
    Welcome to the Cisco Support Community Ask the Expert conversation.This is an opportunity to learn and ask questions of Cisco expert Vignesh R. P. about the Cisco® Nexus 7000 Series Switches and support for the Cisco NX-OS Software platform .
    The Cisco® Nexus 7000 Series Switches introduce support for the Cisco NX-OS Software platform, a new class of operating system designed for data centers. Based on the Cisco MDS 9000 SAN-OS platform, Cisco NX-OS introduces support for virtual device contexts (VDCs), which allows the switches to be virtualized at the device level. Each configured VDC presents itself as a unique device to connected users within the framework of that physical switch. The VDC runs as a separate logical entity within the switch, maintaining its own unique set of running software processes, having its own configuration, and being managed by a separate administrator.
    Vignesh R. P. is a customer support engineer in the Cisco High Touch Technical Support center in Bangalore, India, supporting Cisco's major service provider customers in routing and MPLS technologies. His areas of expertise include routing, switching, and MPLS. Previously at Cisco he worked as a network consulting engineer for enterprise customers. He has been in the networking industry for 8 years and holds CCIE certification in the Routing & Switching and Service Provider tracks.
    Remember to use the rating system to let Vignesh know if you have received an adequate response. 
    Vignesh might not be able to answer each question due to the volume expected during this event. Remember that you can continue the conversation on the  Data Center sub-community discussion forum shortly after the event. This event lasts through through January 18, 2013. Visit this forum often to view responses to your questions and the questions of other community members.

    Hi Vignesh
    Is there is any limitation to connect a N2K directly to the N7K?
    if i have a an F2 card 10G and another F2 card 1G and i want to creat 3 VDC'S
    VDC1=DC-Core
    VDC2=Aggregation
    VDC3=Campus core
    do we need to add a link between the different VDC's
    thanks

  • LMS 4.2.2 Interface utilisation on Nexus 7000

    Hi All,
    I'm trying to poll some interfaces for their utilization on a nexus 7000 through LMS 4.2.2.
    When I create a poller fot the specific instances, the LMS recognises the instances, but after activating the poller I get the error "No Such Instance - The specified instance is not available".
    No info is displayed when I generate an interface utilization report for the specific nexus.
    When I activate the automonitor for interface utilization, the interfaces on the nexus are polled.
    On the cisco website there are some features listed which LMS does not support on the Nexus 7000, but polling is not in that list (neither in the supported feature list).
    Any tips?
    Thanks for your help.
    Joris

    Any Idea..??

  • ESXi 4.1 NIC Teaming's Load-Balancing Algorithm,Nexus 7000 and UCS

    Hi, Cisco Gurus:
    Please help me in answering the following questions (UCSM 1.4(xx), 2 UCS 6140XP, 2 Nexus 7000, M81KR in B200-M2, No Nexus 1000V, using VMware Distributed Switch:
    Q1. For me to configure vPC on a pair of Nexus 7000, do I have to connect Ethernet Uplink from each Cisco Fabric Interconnect to the 2 Nexus 7000 in a bow-tie fashion? If I connect, say 2 10G ports from Fabric Interconnect 1 to 1 Nexus 7000 and similar connection from FInterconnect 2 to the other Nexus 7000, in this case can I still configure vPC or is it a validated design? If it is, what is the pro and con versus having 2 connections from each FInterconnect to 2 separate Nexus 7000?
    Q2. If vPC is to be configured in Nexus 7000, is it COMPULSORY to configure Port Channel for the 2 Fabric Interconnects using UCSM? I believe it is not. But what is the pro and con of HAVING NO Port Channel within UCS versus HAVING Port Channel when vPC is concerned?
    Q3. if vPC is to be configured in Nexus 7000, I understand there is a limitation on confining to ONLY 1 vSphere NIC Teaming's Load-Balancing Algorithm i.e. Route Based on IP Hash. Is it correct?
    Again, what is the pro and con here with regard to application behaviours when Layer 2 or 3 is concerned? Or what is the BEST PRACTICES?
    I would really appreciate if someone can help me clear these lingering doubts of mine.
    God Bless.
    SiM

    Sim,
    Here are my thoughts without a 1000v in place,
    Q1. For me to configure vPC on a pair of Nexus 7000, do I have to connect Ethernet Uplink from each Cisco Fabric Interconnect to the 2 Nexus 7000 in a bow-tie fashion? If I connect, say 2 10G ports from Fabric Interconnect 1 to 1 Nexus 7000 and similar connection from FInterconnect 2 to the other Nexus 7000, in this case can I still configure vPC or is it a validated design? If it is, what is the pro and con versus having 2 connections from each FInterconnect to 2 separate Nexus 7000?   //Yes, for vPC to UCS the best practice is to bowtie uplink to (2) 7K or 5Ks.
    Q2. If vPC is to be configured in Nexus 7000, is it COMPULSORY to configure Port Channel for the 2 Fabric Interconnects using UCSM? I believe it is not. But what is the pro and con of HAVING NO Port Channel within UCS versus HAVING Port Channel when vPC is concerned? //The port channel will be configured on both the UCSM and the 7K. The pro of a port channel would be both bandwidth and redundancy. vPC would be prefered.
    Q3. if vPC is to be configured in Nexus 7000, I understand there is a limitation on confining to ONLY 1 vSphere NIC Teaming's Load-Balancing Algorithm i.e. Route Based on IP Hash. Is it correct? //Without the 1000v, I always tend to leave to dvSwitch load balence behavior at the default of "route by portID". 
    Again, what is the pro and con here with regard to application behaviours when Layer 2 or 3 is concerned? Or what is the BEST PRACTICES? UCS can perform L2 but Northbound should be performing L3.
    Cheers,
    David Jarzynka

  • Privilege Level for Tacacs Account in Nexus 7000

    Hi,
    I have configured the Tacacs (ACS 4.2v) on Nexus 7000 (as mentioned below) and works fine but unlike IOS (6509) It's doesn't prompt that you are in userexec mode (>) and then need to type enable and password for full privilege.
    In n7k when I entered into "configure terminal" It won't allow me to access other commands.
    How to login into level 15 privilege mode after authenticating from tacacs
    (config)# show running-config tacacs+
    tacacs-server key 7 "xxxxx"
    tacacs-server host x.x.x.x key 7 "xxxx"
    aaa group server tacacs+ TacServer
        server x.x.x.x (same ip as tacacs-server host)
        use-vrf management
        source-interface Vlan2
    (config)# show running-config aaa
    aaa authentication login default group TacServer
    aaa authentication login console local
    aaa user default-role
    Here below are the commands accessible in "Terminal" currently
    (config)# ?
      no        Negate a command or set its defaults
      username  Configure user information.
      end       Go to exec mode
      exit      Exit from command interpreter
    isb.n7k-dcn-agg-1-sw(config)#

    Hi Jan.nielsen
    Issue is resolved but by another way.
    I have found the same resolution too of custom attirbute command but the Custom attribute Option for shell command wasn't available in ACS v4.2, so after enabling shell for users and by clicking exec--> Shell Exec and enabling priviledge level 15 in the same box of Shell options, It start working without any command

  • Nexus 7000 - unexpected shutdown of vPC-Ports during reload of the primary vPC Switch

    Dear Community,
    We experienced an unusual behavior of two Nexus 7000 switches within a vPC domain.
    According to the attached sketch, we have four N7Ks in two data centers - two Nexus 7Ks are in a vPC domain for each data center.
    Both data centers are connected via a Multilayer-vPC.
    We had to reload one of these switches and I expected the other N7K in this vPC domain to continue forwarding over its vPC-Member-ports.
    Actually, all vPC ports have been disabled on the secondary switch until the reload of the first N7K (vPC-Role: primary) finished.
    Logging on Switch B:
    20:11:51 <Switch B> %VPC-2-VPC_SUSP_ALL_VPC: Peer-link going down, suspending all vPCs on secondary
    20:12:01 <Switch B> %VPC-2-PEER_KEEP_ALIVE_RECV_FAIL: In domain 1, VPC peer keep-alive receive has failed
    In case of a Peer-link failure, I would expect this behavior if the other switch is still reachable via the Peer-Keepalive-Link (via the Mgmt-Port), but since we reloaded the whole switch, the vPCs should continue forwarding. 
    Could this be a bug or are there any timers to be tuned?
    All N7K switches are running on NX-OS 6.2(8)
    Switch A:
    vpc domain 1
      peer-switch
      role priority 2048
      system-priority 1024
      peer-keepalive destination <Mgmt-IP-Switch-B>
      delay restore 360
      peer-gateway
      auto-recovery reload-delay 360
      ip arp synchronize
    interface port-channel1
      switchport mode trunk
      switchport trunk allowed vlan <x-y>
      spanning-tree port type network
      vpc peer-link
    Switch B:
    vpc domain 1
      peer-switch
      role priority 1024
      system-priority 1024
      peer-keepalive destination <Mgmt-IP-Switch-A>
      delay restore 360
      peer-gateway
      auto-recovery reload-delay 360
      ip arp synchronize
    interface port-channel1
      switchport mode trunk
      switchport trunk allowed vlan <x-y>
      spanning-tree port type network
      vpc peer-link
    Best regards

    Problem solved:
    During the reload of the Nexus 7K, the linecards were powerd off a short time earlier than the Mgmt-Interface. As a result of this behavior, the secondary Nexus 7K received at least one vPC-Peer-Keepalive Message while its peer-link was already powerd off. To avoid a split brain scenario, the VPC-member-ports have been shut down.
    Now we are using dedicated interfaces on the linecards for the VPC-Peer-Keepalive-Link and a reload of one N7K won't result in a total network outage any more.

  • Query Nexus 7000 Enviroment Status

    Hi,
    I am trying to figure out how to query a Nexus 7010 Chassis about its enviroment. For our IOS Switches we use SNMP and OID 1.3.6.1.4.1.9.9.13.1 and the related sub OIDs. But this does not work on the Nexus 7010 with version 5.1. Is querying the information not supported or is there another OID?

    Hi,I am trying to figure out how to query a Nexus 7010 Chassis about its enviroment. For our IOS Switches we use SNMP and OID 1.3.6.1.4.1.9.9.13.1 and the related sub OIDs. But this does not work on the Nexus 7010 with version 5.1. Is querying the information not supported or is there another OID?
    Hi,
    Check out the below link for nexus 7000 MIB reference ..
    http://www.cisco.com/en/US/docs/switches/datacenter/sw/mib/quickreference/Cisco_Nexus_7000_Series_NX-0S_MIB_Quick_Reference_chapter1.html#con_40545
    Hope to Help !!
    Ganesh.H

  • Rule based span on Nexus 7000

    Hi all,
    I'm trying to configure rule based span on my Nexus 7000.
    I want to monitor some vlans, but limit the traffic going to my monitor station by using frame-type ipv4 filter.
    The link below explains how to configure it, but my nexus doesn't recognise the command "mode extended".
    http://www.cisco.com/c/en/us/td/docs/switches/datacenter/sw/6_x/nx-os/system_management/configuration/guide/sm_nx_os_cg/sm_14span.html#wp1286697
    Am I missing something? I'm running version 6.1.3.
    Thanks,
    Joris
    NEXUS(config)# monitor session 1
    NEXUS(config-monitor)# mode extended
                                       ^
    % Invalid command at '^' marker.
    NEXUS(config-monitor)# mode ?
    *** No matching command found in current mode, matching in (exec) mode ***
      connect  Notify system on modem connection
      restart  Reenabling modem port

    Hi Joris,
    The rule based SPAN filtering was not introduced until NX-OS 6.2 so will not be available to you with NX-OS 6.1(3).
    See the section SPAN in the NX-OS 6.2 release notes.
    Regards

Maybe you are looking for

  • Mac OS 10.6.8 and HP LaserJet 5L.

    Hi, To get my printer working i downloaded the  driver HP LaserJet 5L- CUPS Gutenprint v5.2.9. it is working temporarely until i shot off the computer. The next time i need to print something the printer show offline. I have to go to the preferences,

  • When I go to type a message on messages my daughter has managed to get the keyboard in the middle of the screen , how do I return it to the bottom ?

    How do you get the keyboard in messages back to the bottom instead of the middle of the screen...it is really annoying

  • Spry with Flash Video

    Is spry compatible with flash video? I used the Dreamweaver wizard to insert a flash video. I inserted it into a spry region and changed the source of the flash video to be: src="{link}" however, this does not work. I have tried several other javascr

  • JList Selection

    Hello everyone, first of all, excuse me for my poor english. I have a JList contaning nearly 200 items and I would like the maximum selectable item count to be 5. I thought a good way to do that could be to add a listener to the list data and each ti

  • ENQUEUE_EC_PROJ

    Hi Experts, I am facing below problem When executing the FM "ENQUEUE_EC_PROJ" in background for WBS element user status change in work flow. It is not showing any lock objects ( i am using this in the WF to Change the WBS status i.e next Approver ).