I have dual LAN connection on my notebook as enclosed in the first picture.
The NI-FBUS Interface Configuration Utility recognises the connection to the HSE linking device without any errors, see second picture.
Ping to the address is OK, but the NI-FBUS Communications Manager 4.0.1 can not listen to the board 0, see third picture.
Using another notebook separated with only one LAN interface the connection is functioning.
Any ideas on the problem solution?
Attachments:
Dual_LAN_Problem.jpg ‏275 KB
NI_InterfaceConfigurator_OK.jpg ‏101 KB
NI_FBUS CommunicationsManager_Error.jpg ‏138 KB

Hi Chris,
I am not able to stop the Symantec Protection, see the pictures enclosed, perhaps I do not have the right for this application.
Even if I defined the fixed IP addresses as Exceptions not to be scanned, it does not work.
I will discus it at the company next week when I am working there.
Thanks for the hint.
Petr
Attachments:
SymantecExceptions.jpg ‏77 KB
SymantecProtection.jpg ‏22 KB

Similar Messages

  • Communication manager error

    Bonjour à tous,
    En appelant la fonction nifopensession, le ni-fbus communication manager plante et se termine.
    Quelqu'un aurait-il une idée?
    nifb.exe
    appver 4.0.1.49154
    modver 0.0.0.0
    offset 00000000
    Par avance, je vous remercie

    Bonjour,
    J'utilise Borland C++ Builder.
    J'utilise le matériel suivant NI-FBUS PCMCIA.
    Cette erreur se produit lorsque j'appelle la fonction nifopensession.
    En fait j'ai remarqué que lorsque j'utilise la nouvelle dll de la version 4.0.1 (nifb.dll) avec l'ancienne lib de la version 3.2.1 (nifb.lib), ça fonctionne! Ce n'est qu'en incluant la nouvelle lib de la version 4.0.1 (nifb.lib) que le commincation manager s'arrrête lors de l'appel de la fonction nifopensession.
    Cordialement,
    Christophe Roch

  • FBUS Communication 3.1 manager crashes with AT card

    I have version 3.1 of the communications manager which works fine with an application that is written which uses the old NI-FBUS API (the C functions).  On a different appliction which is coded up in a new application which uses the new NI-API (.NET code) the FBUS communications manager 3.1 crashes.  I have an AT FBUS card and wonder if that is a source of the problem.   That being that verions 3.1 of the FBUS Communications manager it is not compatible with an AT card.  I thought someone told me they "figured out a way" to get the communications manager version 3.1 to work on the old AT card???  So question #1 is an AT card compatbile with FBUS communication manager 3.1?
    When FBUS communications manager crashes it is very random and doesn't seem tied to a device under test.  It happens sometime when doing reads, sometimes when doing write....there does not seem to be a specific point or location that it fails.  Again some times it runs fine for a long time and then fails other times it fails almost right away.  I have to restart the communications manager to get it to work again and reconnect a device.  Again my old program that uses the old NI FBUS API works great on the same card with FBUS Communications manager 3.1.

    AT-FBUS is compatible with CM 3.1.
    Have you tried the .NET examples which are installed with NI-FBUS?
    Ryan Shi
    National Instruments

  • Ni-fbus communications cannot connect interface

    I am using NI-FBUS Communications Manager 3.2 with a NI PCMCIA-FBUS Series 2 card in a Ricoh R/RL/... series PCMCIA adapter on a desktop computer.  I enabled the PCMCIA card via the Interface Configuration Utility.  When I start the Comm Manager, I get the following error message:
    NI_FBUS Communications Manager cannot connect interface 0 on the fieldbus board 1. Click OK to.....
    Windows sees the Ricoh adapter card and the Series 2 card as working properly.  If I install the Series 2 card in a laptop, the Comm Manager starts properly.  The same series 2 card and Ricoh adapter card has been used in another desktop computer also running XP SP2.
    How do I get this combination up and running?

    I tried the PCMCIA card and adapter card in another computer running XP and NI-FBUS Communications Manager 3.1.1.  The combination worked properly; the card was seen and the Comm Manager opened.  When Configurator was opened, the device attached to the link was seen.
    Is there a compatibility difference between Comm Mgr 3.1.1 and 3.2?

  • Communication manager 4.0.1 is not working with PCMCIA FBUS

    Hi everybody,
    since i can remember we have got problems with communication manager driver software ( which is comming with the FF ITK ) using with PCMCIA FBUS card.
    I cant use our PCMCIA FBUS 1 or PCMCIA FBUS Series 2 card with the latest communication manager 4.0.1 because the card is not working after installation of the software.

    Hi,
    There is no such limit of CM 4.0.1 to work with PCMCIA-FBUS interface.
    We only have problem with some Dell Laptop because of some hardware issue.
    Please refer to the related discussion link:
    http://forums.ni.com/t5/FOUNDATION-Fieldbus/NI-FBUS-PC-Card-detected-wrong/td-p/1658478
    Also there are several diagnose suggestion for you.
    1. Check the Device Manager to see whether the driver is installed and identified correctly.
    2. Try several PCMCIA-FBUS cards in your Laptop.
    3. Try the same PCMCIA-FBUS card in different Laptop with CM 4.0.1.
    Hope this will help. If any further request, please feel free to email me through [email protected]
    You could get swift reply and support.
    Thanks.
    Chris

  • CRM 7.0 - Communication Management Software - CTI

    Hi,
    We are in process of configuring Contact Center Simulator.
    The fact is that we don't have JAVA stack on CRM 7.0 system, rather we are using different system for JAVA stack.
    We have successfully done with RFC connection in CRM 7.0 pointing to JAVA stack system and other required config settings.
    When user click 'Ready' button from UI, it gives error 'Communication management software system is not configured'.
    Does any body has experenced this or did I missed out any step?
    Regards,
    Nilesh P

    Hi Nilesh,
    Here are a few things to check:
    1. Look at the ICI trace log and see what kind of message is being returned
    2. Double-check your toolbar configuration - this often gets overlooked - you need a toolbar for voice configured
    3. Check that the system where the Java stack resides can "see" and connect to your CRM 7.0 system - if there is a firewall between the two or if there is some other network reason that communication might be getting blocked. look at the ICI trace log and see what url is being passed in the subscribe command, then put that URL into a web browser on the java server to verify that it can call back to the CRM system
    Hope this helps. I have done that same thing before so I know it works.
    Sincerely,
    Glenn
    Glenn Abel
    Covington Creative
    www.covingtoncreative.com

  • Testing of Internet Communication Manager

    When i perform the "Testing of Internet Communication Manager", the internet communication manager is up and running.
    But when i do the following task, i got the error message, i would like to know whether it is critical?
    Execute GoTo -> Trace File and check for problems
    ERROR => IcmConnConnect: No service for protocol HTTP started [icxxconn.c 2128]
    ERROR => HttpPlugInHandleNetData: server: premature EOS (0/-1) in request [http_plg.c 1892]
    Does any expert know why and how to solve it?

    Hi,
    Your SMICM might be ruunig but no HTTP srevice is defined
    ERROR => IcmConnConnect: No service for protocol HTTP started
    Tx code SMICM-->GO TO -->Services check there if not define it .
    Regards,

  • How do i reinstall AT&T Communications Manager?

    I recently bought the Nokie Booklet, yesterday in fact. And i also purchased Windows 7 Home premium. Not knowing that there wasn't a CD tray on the MINI, i donwloaded it to my desktop and then uploaded it do a flash drive. I installed it on my Booklet and now the internet doesn't work. To help myself, i have already went into "Windows.Old" I get this error message.
    "C:\Windows.Old\Program Files\AT&T\Communication Manager\ATTCM.exe
    The application has failed to start because its side-by-side configuration is incorrect. Please see the application event log or use the command-line sxstrace.exe tool for more detail."
    I do realize that the program came with Windows 7 Starter, but that shouldn't mean it doesn't work for a later edition of Windows 7 does it? Yes, i have already tried to restore settings to factory default. And system recovery, it doesn't work because i haven't set any recover time before hand. So is there a way to get the new ATTCM.exe? All help appreciated.
     - Austin
    P.S How do i connect the internet from my desktop to my laptop, is it manditory that i use an Ethernet-to-USB adapter?

    There is a partition on the HDD that is the factory restore. You can restore the booklet to factory unless you did a clean install and wiped out the partition. When it's booting up press F8, and repair.

  • Unable to invoke SendMessage method of outbound communications manager

    i have configured a communication profile, and tried to send a mail using Outbound Comm Manger.
    When i use F9 i am able to send the mail. But wheni try to automate the processby workflows i get the following error.
    "Unable to invoke SendMessage method of outbound communications manager"
    I have used"SendMessage" method of outbound communications manager.
    CommProfile - Literal - MyProfile
    MsgTo List - Literal Value
    is there any extra parameters have to give in workflow??
    Kindly help me on this. What are the extra parameters that i need to give in the Internet SMTP/POP3 Server PARAMETER in Comm Profiles.
    Thanks in Advance

    A.Pancholi wrote:
    However, if you shutdown the OS and it just kills the JVM process, it won't happen. Is that correct?
    No, it should still run. It's what shutdown hooks are for, cleaning up, eg: database connections, in the case of unexpected shutdowns. Not foolproof, by any means, though. Pulling the power cord won't run them, for obvious reasons
    So actually, it probably is what the OP is afterThen we could be the problem the method is not getting invoked. Did we do something wrong: We show you what we have done.
    Runtime.getRuntime().addShutdownHook(new Thread() {
    public void run() {
    callingMyMethod();
    Looks fine to me. How are you stopping the JVM?

  • Outbound Communications manager

    I am working on a requirement where i have a send an Email to the Service Request Contact when a new Service Request is created.I am using the Outbound Communications Manager BS and Create and Submit request method to send the Email.
    The Email is going to the Service Request contact which are loaded through EIM.But the Email is not sent to the Contacts which are created in the UI.This is the error which i could see
    Unable to process source instance 1-AEULR. No recipients are associated with the instance
    Sent 0 out of 0 messages. Please check the log for details.
    Please let me know if any one has faced this issue..or if any more details are required.

    Hi,
    I am working on Siebel 8.
    When ever a new contact is created from UI the PR_POSTN_ID is not populated and a record doesnt get created in S_POSTN_CON table.
    This is the SQL which its generated andthe contact is not retrieved.
    SELECT /*+ ALL_ROWS */
    T7.CONFLICT_ID,
    T7.LAST_UPD,
    T7.CREATED,
    T7.LAST_UPD_BY,
    T7.CREATED_BY,
    T7.MODIFICATION_NUM,
    T7.ROW_ID,
    T21.MEMBER_FLG,
    T21.MID_NAME,
    T21.OWNER_PER_ID,
    T7.NAME,
    T21.PERSON_UID,
    T21.PREF_COMM_MEDIA_CD,
    T21.PR_OU_ADDR_ID,
    T1.NAME,
    T17.PR_ADDR_ID,
    T21.PR_AFFL_ID,
    T21.PR_EMAIL_ADDR_ID,
    T21.PR_ALT_PH_NUM_ID,
    T21.PR_REP_DNRM_FLG,
    T21.PR_REP_MANL_FLG,
    T21.PR_REP_SYS_FLG,
    T21.PR_MKT_SEG_ID,
    T19.PR_EMP_ID,
    T6.PR_EMP_ID,
    T11.LOGIN,
    T14.LOGIN,
    T21.PR_GRP_OU_ID,
    T21.PR_INDUST_ID,
    T21.PR_NOTE_ID,
    T21.PR_OPTY_ID,
    T21.BU_ID,
    T21.PR_SYNC_USER_ID,
    T21.PR_PER_ADDR_ID,
    T21.PR_POSTN_ID,
    T21.PR_PROD_LN_ID,
    T21.PR_RESP_ID,
    T21.PR_SECURITY_ID,
    T4.NAME,
    T21.MED_SPEC_ID,
    T21.PR_STATE_LIC_ID,
    T21.PR_TERR_ID,
    T21.PROVIDER_FLG,
    T21.RACE,
    T21.WEB_REGION_ID,
    T10.OWN_INST_ID,
    T10.INTEGRATION_ID,
    T9.SHARE_HOME_PH_FLG,
    T21.CUST_SINCE_DT,
    T21.SUPPRESS_MAIL_FLG,
    T20.ADDR,
    T20.CITY,
    T20.COUNTRY,
    T20.ZIPCODE,
    T20.STATE,
    T21.WORK_PH_NUM,
    T21.PR_DEPT_OU_ID,
    T1.PRTNR_FLG,
    T21.PR_REGION_ID,
    T21.CON_IMAGE_ID,
    T5.ATTRIB_07,
    T21.EMAIL_ADDR,
    T21.ALT_EMAIL_ADDR,
    T21.EMP_FLG,
    T21.EMP_ID,
    T21.FAX_PH_NUM,
    T21.FST_NAME,
    T21.HOME_PH_NUM,
    T21.AGENT_FLG,
    T21.JOB_TITLE,
    T21.LAST_NAME,
    T15.ROW_STATUS,
    T8.LOGIN,
    T18.PR_SRV_AGREE_ID,
    T3.ROW_ID,
    T18.INTEGRATION_ID,
    T18.NAME,
    T18.LOC,
    T18.PR_BL_ADDR_ID,
    T18.PR_BL_PER_ID,
    T18.PR_SHIP_ADDR_ID,
    T18.PR_SHIP_PER_ID,
    T18.CUST_STAT_CD,
    T18.OU_TYPE_CD,
    T18.OU_NUM,
    T3.ROW_ID,
    T16.LOGIN,
    T21.ROW_ID,
    T21.PAR_ROW_ID,
    T21.MODIFICATION_NUM,
    T21.CREATED_BY,
    T21.LAST_UPD_BY,
    T21.CREATED,
    T21.LAST_UPD,
    T21.CONFLICT_ID,
    T21.PAR_ROW_ID,
    T9.ROW_ID,
    T9.PAR_ROW_ID,
    T9.MODIFICATION_NUM,
    T9.CREATED_BY,
    T9.LAST_UPD_BY,
    T9.CREATED,
    T9.LAST_UPD,
    T9.CONFLICT_ID,
    T9.PAR_ROW_ID,
    T5.ROW_ID,
    T5.PAR_ROW_ID,
    T5.MODIFICATION_NUM,
    T5.CREATED_BY,
    T5.LAST_UPD_BY,
    T5.CREATED,
    T5.LAST_UPD,
    T5.CONFLICT_ID,
    T5.PAR_ROW_ID,
    T10.ROW_ID,
    T10.PAR_ROW_ID,
    T10.MODIFICATION_NUM,
    T10.CREATED_BY,
    T10.LAST_UPD_BY,
    T10.CREATED,
    T10.LAST_UPD,
    T10.CONFLICT_ID,
    T10.PAR_ROW_ID,
    T15.ROW_ID,
    T13.ROW_ID,
    T3.ROW_ID,
    T12.ROW_ID
    FROM
    SIEBEL.S_ORG_EXT T1,
    SIEBEL.S_POSTN T2,
    SIEBEL.S_PARTY T3,
    SIEBEL.S_MED_SPEC T4,
    SIEBEL.S_CONTACT_X T5,
    SIEBEL.S_POSTN T6,
    SIEBEL.S_PARTY T7,
    SIEBEL.S_USER T8,
    SIEBEL.S_EMP_PER T9,
    SIEBEL.S_CONTACT_SS T10,
    SIEBEL.S_USER T11,
    SIEBEL.S_PARTY T12,
    SIEBEL.S_PARTY T13,
    SIEBEL.S_USER T14,
    SIEBEL.S_POSTN_CON T15,
    SIEBEL.S_USER T16,
    SIEBEL.S_POSTN_CON T17,
    SIEBEL.S_ORG_EXT T18,
    SIEBEL.S_POSTN T19,
    SIEBEL.S_ADDR_PER T20,
    SIEBEL.S_CONTACT T21
    WHERE
    T21.PR_DEPT_OU_ID = T1.PAR_ROW_ID (+) AND
    T1.PR_POSTN_ID = T19.PAR_ROW_ID (+) AND
    T21.PR_POSTN_ID = T6.PAR_ROW_ID (+) AND
    T7.ROW_ID = T17.CON_ID (+) AND T17.POSTN_ID (+) = '0-5220' AND
    T19.PR_EMP_ID = T11.PAR_ROW_ID (+) AND
    T6.PR_EMP_ID = T14.PAR_ROW_ID (+) AND
    T21.PR_PER_ADDR_ID = T20.ROW_ID (+) AND
    T21.MED_SPEC_ID = T4.ROW_ID (+) AND
    T7.ROW_ID = T21.PAR_ROW_ID AND
    T7.ROW_ID = T9.PAR_ROW_ID (+) AND
    T7.ROW_ID = T5.PAR_ROW_ID (+) AND
    T7.ROW_ID = T10.PAR_ROW_ID (+) AND
    T21.PR_POSTN_ID = T15.POSTN_ID AND T21.ROW_ID = T15.CON_ID AND
    T15.POSTN_ID = T13.ROW_ID AND
    T15.POSTN_ID = T2.PAR_ROW_ID (+) AND
    T2.PR_EMP_ID = T8.PAR_ROW_ID (+) AND
    T21.PR_DEPT_OU_ID = T3.ROW_ID (+) AND
    T21.PR_DEPT_OU_ID = T18.PAR_ROW_ID (+) AND
    T21.PR_SYNC_USER_ID = T12.ROW_ID (+) AND
    T21.PR_SYNC_USER_ID = T16.PAR_ROW_ID (+) AND
    (T21.PRIV_FLG = 'N') AND
    (T7.ROW_ID = '1-AF4PK')
    ORDER BY
    T21.LAST_NAME, T21.FST_NAME
    Please let me know if any findings.

  • New Community Manager?

    I just spotted a NigelE who's a Community Manager.
    But no mention of him here Has Kerry gone? Are there now two managers? Would you care to introduce yourself Nigel? Do you intend to make any improvements to the BTCare forums?
    Value Added Guest (Inspiring Not Aspiring)
    Rate a post if you like it! - just click the star under the user's name on the left. (N.B. ratings facility no longer available in Forum Help and Suggestions; nor is it available in the Lounge)

    Hi Pasha_Selim
    Thanks for the post.  There was an error in the status showing for NigelE, this has now been corrected.  Nigel is a mod and his bio will be uploaded in the 'meet the mods' section soon.
    Thx
    Kerry
    Retired BTCare Community Manager - StephanieG and SeanD are your new Community Managers
    If you like a post, or want to say thanks for a helpful answer, please click on the Ratings star on the left-hand side of the post.
    If someone answers your question correctly please let other members know by clicking on ’Mark as Accepted Solution’.

  • Open management shell with a error

    Hi 
    when I open the exchange management shell . The error code will show below.
    VERBOSE: Connecting to myservername.mydomain.com
    New-PSSession : [myservername.mydomain.com] Connecting to remote server myservername.mydomain.com failed with the following
    error message : WinRM cannot process the request. The following error with errorcode 0x80090324 occurred while using
    Kerberos authentication: There is a time and/or date difference between the client and server.
     Possible causes are:
      -The user name or password specified are invalid.
      -Kerberos is used when no authentication method and no user name are specified.
      -Kerberos accepts domain user names, but not local user names.
      -The Service Principal Name (SPN) for the remote computer name and port does not exist.
      -The client and remote computers are in different domains and there is no trust between the two domains.
     After checking for the above issues, try the following:
      -Check the Event Viewer for events related to authentication.
      -Change the authentication method; add the destination computer to the WinRM TrustedHosts configuration setting or
    use HTTPS transport.
     Note that computers in the TrustedHosts list might not be authenticated.
       -For more information about WinRM configuration, run the following command: winrm help config. For more
    information, see the about_Remote_Troubleshooting Help topic.
    At line:1 char:1
    Any solutions can help .?

    Hi,
    According to error code, it’s mostly likely related to the time sync.
    Thus, let’s try to manually synchronize the computer with the time on the domain.
    1.Click Start, and then click Run.
    2.Type net time /domain /set, and then click OK.
    If you have any question, please feel free to let me know.
    Thanks,
    Angela Shi
    TechNet Community Support

  • Cisco Unified Communications Manager Attendant Console issue with cucm ver 9.1.1

    Dear support,
    As we used before Cisco Unified Communications Manager Attendant Console with CUCM version 7.x as now we upgrade to version 9.1.1 and we could not be able to use this service .due to attendant console is not available with cucm versio 9.1.1.
    before upgrade cucm ver 7.x  from PC user maintain all contact details store with Attendant console software on his desktop PC.  right now its give error unable to connect to the server. due to attendant console is not available with cucm version 9.1.1.
    So how i can retrieve the user store contact details from attendant console software from his PC desktop .
    so please provide you feedback highly appreciate.
    Regards
    syed

    Dear support,
    As i check this on user  pc c:\program files\cisco\Unified Communications Manager Attendant Console\data\GlobalSettings.xml
    I couldn't  be able to retrieve the store contact data .most of the user are get effected by this service. 
    As we do upgrade to cucm versioun 9.1.1 to use of more services but not user are to be get effect by the attendant  services like we can't use Attendant console software on CUCM 9.1.1 after upgrade......
    so please advice ........... atleast we need to retrieve the user store contact data ...
    Highly appreciate for your resposne .....
    regards
    syed

  • PAP2T and Cisco Unified Communications Manager

    I try to connect pap2t to Cisco Unified Communications Manager rel 6.1.2. I Enabled digest authentication, create end user with name like DN, linked it with phone and DN. But pap2t can't register - Can't connect to login server.CUCM - say me that this phone status - rejected. Can anybody help me?

    We do see this occasionally and generally 95% of the time it's the router blocking the SIP traffic, the error "Can't connect to Logon server" means it's getting no reply, what I think you may find is that your device may be setup as DHCP and the router may be doing a renew of lease (Ie IP address to the device) every 24 hours, this could be the problem.
    Try setting your device to a Static IP Address and make sure you also set the DNS entries as well, see how you go after that.

  • No Devpack Available - Communications Manager

    I have a requirement to deploy Cisco 8811 IP Phones on our current Communications Manager 10.0.1 which it at present does not support.  According to the compatibility matrix there is "No Devpack Available" for this version.  There is a devpack available for version 10.5.1 however this system is running under HCS version 10.0.1 which prevents me from upgrading to 10.5.1.
    http://www.cisco.com/c/en/us/td/docs/voice_ip_comm/cucm/compat/devpack_comp_mtx.html
    Does anyone know if it is possible to apply the 10.5.1 devpack to 10.0.1 Communications Manager?  If not, is there any other way to deploy an 8811 on version 10.0.1?

    No, the DevPacks are tied to a CUCM version, you'll get an error if you try.
    I don't see any device enabler, but sometimes they're not available on cisco.com, you can try opening a TAC to find out if there is, and to have them publish it for you.

Maybe you are looking for