NI-Motion PXI Card Device Status = Is Not Responding

I am unable to communicate with my NI PXI-7358 motion controller card.  The general tab in MAX for the card shows that "Device Status" = "Is Not Responding" see attached.  I have un-mapped and re-mapped the remote device.  I have also removed and re-seated the PXI card without any success.
Solved!
Go to Solution.
Attachments:
PXI-7358 - Is Not Responding.PNG ‏29 KB

Hi Jeffmg, 
This seems to be a known issue. There is an internal knowledgebase documenting this problem and a potential solution. 
The solution according to the KB article:
"This problem can occur when a previous board was mapped to the host machine. The NIMtnSvr.exe is based on Board ID's and sometimes gets stuck. To fix this, close any NI software running and then open the task manager and end the NIMtnSvr.exe process. This will shutdown the server and allow it to start from scratch the next time it runs. When you open MAX, the boards will appear on the local host correctly mapped."
-N
National Instruments
Applications Engineer

Similar Messages

  • PXI Card Status = Is Not Responding

    I am unable to communicate with my NI PXI-7358 motion controller card (NI-Motion 6.1.2 Driver, Max 3.1.1, LabVIEW 7.1, Windows XP).  The general tab in MAX for the card shows that "Device Status" = "Is Not Responding" see attached.  I have un-mapped and re-mapped the remote device.  I have also removed and re-seated the PXI card without any success.  Does this mean the card is no longer functioning and needs to be replaced?  How can I further investigate this issue?
    Solved!
    Go to Solution.
    Attachments:
    PXI-7358 - Is Not Responding.PNG ‏29 KB

    Duplicate issue of http://forums.ni.com/t5/Motion-Control-and-Motor-D​rives/NI-Motion-PXI-Card-Device-Status-Is-Not-Resp​...

  • Pxi cards on 1000b cahssis not detected under windows 98

    my mxi-3 card is being detected on windows startup (mxi-3 optimization software is running correctly) but all other pxi cards on my 1000b pxi chassis are not detected.

    Anis,
    Well, I always prefer to try the simplest things first. In this case, that would be fully powering down the chassis and the computer. Then powering on the chassis first, and a few seconds later, powering on the computer. If this doesn't help, then you would probably want to try any or all of the following troubleshooting steps to try and isolate the problem:
    - Try removing all but the mxi-3 and one other card from chassis and then try booting up.
    - Try placing the pci mxi-3 card in a different slot in the computer.
    - Try uninstalling and reinstalling all the NI software on your computer. (better yet, format and reinstall).
    - Try the pci mxi-3 card in a different computer.
    - Try a different set of mxi-3 cards (if available)
    - Check
    device manager to see if there are any errors or warnings.
    So those are the things that I would try. If after all that you still have no luck connecting you may have a hardware problem and need to RMA (Return Materials Authorization) your hardware.
    Please post back with what you find.
    Regards,
    Jed R.
    Applications Engineer
    National Instruments

  • IPhoto hung importing photos from SD card and is now not responding

    Importing photos from SD card (canon raw format) and iPhoto hung and is no longer responding have to firce quit to get out of it.  Suggestions on reinstalling iPhoto. or?

    I was able to resolve the issue through forcing the image capture program to quit through the activity monitor and reboot the machine and everything seems to function fine now.  Imported the pics, all 240 of them in RAW format.

  • Application, once built, shows "Not Responding" in the toolbar, and it doesn't go away

    If you have an application that is running with some kind of timeout, (My application will send a message, and wait for a user definable period of time for a reply). If this tine is over 5 seconds, and the user clicks on the application, the app sets its status to "(Not Responding)". This is mirrored on the toolbar.
    Once the application begins responding again, the title bar of the app changes back to an active state, although the representation of the app on the tool bar stays in a "(Not Responding)" state.
        I have attempted to stop the user click having an effect by setting the cursor to busy and setting the "Click Disable" to TRUE, but this does not help.
    Any ideas how to get round this one? Or is it a bug?
    Cheers, Alec

    I must not be explaing myself propperly.
    Every application that is open has an instance in the task bar
    As you can see here, I am running outlook, labview, firefox and MSN, but don't tell my boss
    Somtimes, when windows things an application has crashed it will place the phrase "(Not Responding)" next to it's name in the task bar. It will also place the word "(Not Responding)" In the title bar for the application.
    I have written a program that calls a .dll. The function of this .dll is to read incomming data up the RS-232 socket of my PC. I can set a timeout on this, lets say I set it to 1 minute.
    The application is running, I call the .dll to read incoming data, then I don't produce any incoming data. The application will wait, up to 60 seconds for some data, but in the mean time, Windows thinks the LabVIEW executable file has crashed, so places the word "(Not responding)" in the taskbar AND in the title bar. At this point I send my data up the 232, the data is received and displayed by the application. At this point Windows forgives LabVIEW and the "(Not Responding)" status is revolked. This phrase is then removed from the title bar, but IS NOT removed from the task bar.
    Does anyone know if we have control over this, or should I report it as a bug to National Instruments?
    Many thanks guys,
    Cheers, Alec

  • IE in not responding state

    i am using oracle Report builder 9i and Application server 10g.when i run my report with huge data on report builder, it runs fine but when i run that report on Internet Explorer in htmlcss format through AS 10g with huge data it runs fine also but the problem is when i select any data with mouse on IE then IE status becomes "Not responding" state.
    any solution?

    Hi Scott,
    Is the server 2012 R2?
    Please confirm in the logs that a disconnect/reconnect is occurring.  On the client you would look at TerminalServices-ActiveXCore and on the server side you would look at TerminalServices-LocalSessionManager.
    When this happened you had a continuous ping to the server and it did not lose any pings?
    Having solid pings is a good sign, but you can still have a network problem that will cause the connection to drop.  You may want to update the NIC driver and firmware to the latest version recommended by your server manufacturer.
    Additionally you should consider any routers/switches/etc. that are between the clients and the server as potentially suspect.  For example, I have seen where a NAT router would drop a connection periodically, then the connection would be re-established
    and not have issues (until the next time).  One way to test would be to swap in a different make and model router/switch and see if the problem still exists.
    Thanks.
    -TP

  • MacBook bluetooth will not respond

    I am a huge fan of built in bluetooth. I use it with my phone as a wireless model, I send files, make skype calls, and even listen to music on the sales floor. About one month ago I noticed that it would not connect to the phone to sync. I didn't think much of it at the time. Then I noticed that it would not do anything.
    I can activate bluetooth from the menu bar. I can navigate to any menu I need just fine, but when I try to send a file or search for a new device it will not respond. The button will react for a second but it will not search or send.
    In Internet connect the error I get is "Cannot open the communication device." Same when I try to change the sound settings to my headset.
    This is from a fresh install after my hard drive failed, under any and all user accounts. I reset the Pram also.
    I am thinking I need a new bluetooth module
    Here is what it shows under System Profiler
    Apple Bluetooth Software Version: 1.7.9f12
    Services:
    Bluetooth File Transfer:
    Folder other devices can browse: ~/Public
    Requires Authentication: No
    State: Disabled
    Bluetooth File Exchange:
    Folder for accepted items: ~/Desktop
    Requires Authentication: Yes
    When other items are accepted: Ask
    When PIM items are accepted: Ask
    When receiving items: Prompt for each file
    State: Enabled
    The obvious answer will be "bring it into an apple store. I am hoping there is some easy fix that I overlooked.
    Thanks,
    Brian

    Anyways I wouldn't bother doing an
    archive and install if you don't have the time, but
    it could possiably be software...and that would have
    a good chance of solving it.
    I wish that was the case. I just did a clean install when I got the new hard drive so it shouldn't be software. I really didn't want to have to ship it in.

  • Illustrator "not responding" with networked account

    Hello
    1st time here...
    We are running a small network of 33 iMacs (current Thunderbolt edition) on MacOS 10.6.8, attached to a MacPro Server running MacOS X Server 10.6.8.
    We have about 130 users (school environment).
    As maybe a speciality, the user home folders are on the Server in the Directory called "Home" (which is not on the server boot volume)
    We bought a Volume Licence of CS Master collection vesrion 5.5.
    We tweaked Adobe Acrobat to not crash following the redirect advices given elsewhere....
    But we have no luck getting Illustrator to do what it should on these networked accounts...
    What it does: click the Icon in the Dock (or double click the Application Icon in Finder):
    it bounces a few seconds in the Dock and comes to rest. No splash screen or any kind of message.
    If we look in Activity Monitor, Illustrator is in status of "not responding".
    If I check the Log Illustrator writes in it's log, it stops after verifying the serial number.
    I already contacted the local (Swiss) Adobe support by telephone, they told me:
    if Illustrator runs with a local administrator account, we cannot help you
    I contacted Adobe Live chat this morning. They told me to contact the phone number that gave me the above answer...
    Any hints? I seem to be running in circles...
    (sorry for english terms, it is not my native language, and i'm trying to translate from a german speaking Mac system)
    Andreas

    well, I did not change the operating system, I changed computers (server and clients) which came with a new operating system :-). The new computers probably would not run with the old operating system (10.4.11) and is not really good punblicity as a school to run old versions of applications ;-)
    I got it running today...
    For the records: Our support suggested to redirect
    ~/Library/Caches/Adobe/
    ~/Library/Caches/AdobeHelpData/
    to the local disk.
    I did not find
    ~/Library/Caches/AdobeHelpData/
    in the folders of a local user who had already started Illustrator once, so in the end I redirected the whole
    ~/Library/Caches/
    to the local disk. This might be too much for the problem I had to solve, but seems to do the trick and doesn't seem to have bad sideeffects...

  • Why are my PXI cards not recognized by Windows or MAX?

    I have a PXI-1045 chassis connected to a PC through MXI-4.  When I turn the chassis and PC on with a PXI card in slot 2, the message "Windows could not load the installer for DAQDevice.  Contact your hardware vendor for assistance." appears, and the PXI card is not recognized (it is scene by Windows as an unidentifiable PCI Devices, though I have a DAQmx installed).
    More details:
    Windows XP
    LabVIEW 8.0 installed
    TestStand 4.0 installed
    Latest DAQmx 8.XX installed
    NI Scope installed
    NI CAN installed
    MXI-4 PCI card installed in PC and recognized by Windows (as PCI-PCI bridge, and MXI-4 Device)
    I identified PXI chassis 1045 in MAX and on subsequent boot up saw that MAX complained about pxisys or some other ini file (in the chassis status area of the screen) so I configured it as 'other' then put in the PXI-resorce CD and selected the ini file for PXI-1045, MAX no longer complains about pxisys and instead says the chassis is configured properly
    If I have nothing but the PXI MXI-4 card installed in the PXI system and boot up the chassis then the PC, I get no errors
    If I have a card in slot two (I've tried PXI-6509 Industrial Digital IO, PXI-2569 Relay Module, and PXI-5102 Digital Oscilliscope) and boot the chassis then PC, the message "Windows could not load the installer for DAQDevice.  Contact your hardware vendor for assistance." shows up when Windows boots and Windows sees a PCI Device but can't identify any drivers for it. 

    Hello,
    Can you post a screenshot of the problem? Are you switching on the chassis first or the PC? Please make sure that you switch ON chassis and then boot the PC. This typically happens when you have a corrupted installation.  I would suggest downloading the latest version of driver from here and re-installing it.
    Please uninstall all the driver software from computer before installing the new software.
    http://digital.ni.com/softlib.nsf/websearch/d31d46​fffb745eca862571490053eab8
    Thanks,
    Kalyan
    Applications Engineer
    National Instruments

  • IVI error will not run PXI cards calibration

    I had an NI automatic update done a week or so ago and it wiped out my ability to run NIMAX, Calibration Executive, and see any of my PXI card plugins. I am using a PXI-1033 mainframe and calibrating multipe PXI cards. I was able to fix NIMAX and I can now see my mainframe and cards in the mainframe, but I cannot communicate with the cards. When I start my computer I get a "found new hardware wizard" looking for a PCI Device but have no luck when I downloaded all the drivers once again. In MAX the card is there but says "windows does not have a driver associated with my device" even after installing it three times. When I tried running Calibration Executitve I get the error message "ProcessModel\QueryDriverVersions\specificDrivers\cex_Read_NI_SCOPEVersion.viat step QueryDriver Versions LabView: The VI is not executable. Most likely the VI is broken or one of its VIs cannot be located. OPen the VI in labview using flie>>Open and verify it is runable."

    Here is the report for what I am seeing when I first start up MAX. The error code said “NI Service Locator is not running”, See attachment.
    I use this NI Software to calibrate PXI cards listed below using a NI PXI-1033 mainframe. PXI cards are:
    PXI-4070
    PXI-4461
    PXI-5441
    PXI-5600
    PXI-5610
    PXI-5620
    When I run Calibration Executive to calibrate a PXI-5600, I see the error code “Error-603 occurred at Open RegistryKey.vi at step Query Driver Versions.
    Possible reasons: LabVIEW: Specified key or value does not exist.
    When I run Calibration Executive to calibrate a PXI-5620, PXI-5122, I see the error code “Error 1003 occurred at Open VI Reference in cex_ReadDriverVersion.vi-
    >cex_FindProcedureINIAndGetVersionInfo. Vi-
    >cex_FindProcedureINIAndGetVersionInfo. Vi.ProxyCaller
    VI Path: C:\Program Files\National Instruments\Calibration Executive\Source\vi.lib\
    ProcessModel\QueryDriverVersions\specificDrivers\cex_Read_NI_SCOPE_Version.vi
    At step Query Driver Versions
    LabVIEW: The VI is not executable. Most likely the VI is broken or one of its subVIs cannot be located. Open the VI in LabVIEW using File>>Open and verify that it is runnable.
    Possible Reasons:
    LabVIEW: The VI is not executable. Most likely the VI is broken or one of its subVIs cannot be located. Open the LabVIEW using file>> Open and verify that it is runable.
    When I run Calibration Executive to calibrate a PXI-5620, I see the error code “Error 1003 occurred at Open VI Reference in cex_ReadDriverVersion.vi-
    >cex_FindProcedureINIAndGetVersionInfo. Vi-
    >cex_FindProcedureINIAndGetVersionInfo. Vi.ProxyCaller
    VI Path: C:\Program Files\National Instruments\Calibration Executive\Source\vi.lib\
    ProcessModel\QueryDriverVersions\specificDrivers\cex_Read_NI_DMM_Version.vi
    At step Query Driver Versions
    LabVIEW: The VI is not executable. Most likely the VI is broken or one of its subVIs cannot be located. Open the VI in LabVIEW using File>>Open and verify that it is runnable.
    Possible Reasons:
    LabVIEW: The VI is not executable. Most likely the VI is broken or one of its subVIs cannot be located. Open the LabVIEW using file>> Open and verify that it is runable.
    When I run Calibration Executive to calibrate a PXI-5610, I see the error code “Error 1003 occurred at Open VI Reference in cex_ReadDriverVersion.vi-
    >cex_FindProcedureINIAndGetVersionInfo. Vi-
    >cex_FindProcedureINIAndGetVersionInfo. Vi.ProxyCaller
    VI Path: C:\Program Files\National Instruments\Calibration Executive\Source\vi.lib\
    ProcessModel\QueryDriverVersions\specificDrivers\cex_Read_NI_RFSG_Version.vi
    At step Query Driver Versions
    LabVIEW: The VI is not executable. Most likely the VI is broken or one of its subVIs cannot be located. Open the VI in LabVIEW using File>>Open and verify that it is unable.
    Possible Reasons:
    LabVIEW: The VI is not executable. Most likely the VI is broken or one of its subVIs cannot be located. Open the LabVIEW using file>> Open and verify that it is runable.
    When I run Calibration Executive to calibrate a PXI-5441, I see the error code “Error 1003 occurred at Open VI Reference in cex_ReadDriverVersion.vi-
    >cex_FindProcedureINIAndGetVersionInfo. Vi-
    >cex_FindProcedureINIAndGetVersionInfo. Vi.ProxyCaller
    VI Path: C:\Program Files\National Instruments\Calibration Executive\Source\vi.lib\
    ProcessModel\QueryDriverVersions\specificDrivers\cex_Read_NI_FGEN_Version.vi
    At step Query Driver Versions
    LabVIEW: The VI is not executable. Most likely the VI is broken or one of its subVIs cannot be located. Open the VI in LabVIEW using File>>Open and verify that it is runnable.
    Possible Reasons:
    LabVIEW: The VI is not executable. Most likely the VI is broken or one of its subVIs cannot be located. Open the LabVIEW using file>> Open and verify that it is runable.
    I can successfully calibrate a:
    PXI-4461
    Attachments:
    ni_support.zip ‏1184 KB

  • Everytime I purchase using iTunes on my home computer it asks me to verify my c/card, and states "Your Apple ID, ..., was just used to purchase ... from the iTunes Store on a computer or device that had not previously been associated with that Apple ID.

    When i use my laptop to make an iTunes store purchase, it always asks me to verify my account details by entering my credit card verification number. After i do this i then receive an email stating "Your Apple ID, ..., was just used to purchase ... from the iTunes Store on a computer or device that had not previously been associated with that Apple ID."
    My Laptop is my home device and apart from purchasing app's on my iphone 4, i only use my laptop to make itunes purchases.

    I'm having a similar problem.  I had previously (over a year ago) purchased 2 episodes of Law & Order.  Then about 2 months ago, I purchased the 3rd season of Sons of Anarchy.  When I downloaded these episodes to my iPad, about a dozen full seasons of various shows popped up, too.  No money was removed from my iTunes account & theses particular shows aren't in my iTunes library on my desktop.  I've tried every which way to delete them from my ipad, but can't.  I went to the Apple store & they suggested I contact expresslane.apple.com for help.  I submitted my problem, via email Friday, as they asked, but have not received any response.  Any suggestions on how to get rid of these "phantoms?".

  • Hi pls help me my iphone is forest i update but  after my iphone is  devices open is not working i click but sim card installed , attempting to activate this one coming pls help me answer me

    hi pls help me my iphone is forest i update but  after my iphone is  devices open is not working i click but sim card installed , attempting to activate this one coming pls help me answer me

    Sounds like your phone was hacked to use with your carrier.  Updating it has relocked the phone to it's original carrier.  You will not get the phone working again without a SIM from the original carrier.

  • Sat P105-S2036 WinVista SD memory card device not shown in WIndows Explorer

    The label on the botton of the laptop says the Model Number is PSPAOU-1W2036. I have had it for about 2 years. It has a single slot SD memory card only reader in the front. During this time till 2 days ago, it ran factory installed Windows XP MCE just fine. This SD reader shows up in Device Manager as well as in My Computer Windows Explorer window as a drive with letter D since I renamed the DVD drive to letter R. During the last two days, I successfully upgraded the operating system to Windows Vista Ultimate. Everything works fine except that the SD memory card reader no longer shows in neither Device Manager, nor Windows Explorer. But the Device Manager does show a working SDA Standard Compliant SD Host Controller, and a nonworking Mass Storage Controller (missing driver) under Other devices (See Attachment 1). What needs to be done to make the SD memory card reader a working device in Windows Vista? Thank to answers in advance.
    Solved!
    Go to Solution.
    Attachments:
    01 Device Manager shows SD Controller but no SD reader device.txt ‏2 KB

    Thanks to Moderator Trina for moving my inquiry to Moved: /t5/General-Technology/Sat-P105-S2036-WinVista-SD-memory-card-device-not-shown-in/m-p/34845#U34845
    There I searched for SD and found co-member kaidssss' 2009 February 27's post "SD memory Cards Slots" which was resolved by Super Contributor Jerry_Lippey in less than 3 hours with this CSD.Toshiba.com driverweb page
    TI Card Reader Driver for Windows Vista/XP at
    http://www.csd.toshiba.com/cgi-bin/tais/support/jsp/download.jsp?soid=1713025
    THANKS.

  • Has anyone tried to pair the Tzumi bluetooth headphones to their iMac?  My iMac will detect the device, connect to it for about 2 seconds, then shows a status of "not connected".  Multiple attempts get the same result.

    Has anyone tried to pair the Tzumi bluetooth headphones to their iMac?  My iMac will detect the device, connect to it for about 2 seconds, then shows a status of "not connected".  Multiple attempts get the same result.

    Edge has very clear restrictions, one being that you must have 6 months of clean payment history which you don't. Either wait until April 14, or good luck at Sprint.
    I am unsure how it can be determined the payment mix up was the fault of CS, but regardless, the mix up was done. There can be any number of reasons why a payment could be missed without any fault on your part, however you are still the responsible party for the account and must live with the repercussions.

  • Motion controller card need to program PWM or not?

    I just want to know about motion controller card (coz may be i will use it)
    First, Motion controller card need to program PWM for drive DC motor or not? (If I want to control the dc motor by PWM signals!)
    Second, If my motor have encoder (increment) the motion controller card can be read the position or speed directly or not?
    Third, Normally motion controller card need Labview for programming or not?
    Lastly, Please, could someone give me some example programming or .vi for basic closed-loop dc servo motor ?

    bkk,
    here are the answers you are looking for
    Motion Control boards like the PCI-7344 generate a +/-10 V signal to control DC axes. As they can't provide enough power to drive a motor directly an external power amplifier like the MID-7654 or a 3rd party drive with a +/- 10 V command input is necessary. Typically these power drives generate  PWM power signals for the motors.
    All NI motion control boards provide inputs for quadrature encoder feedback (position and velocity).
    The NI-Motion driver provides a well documented API for LabVIEW, C and other programming languages.
    After installing the NI-Motion driver you will find lots of example programs for LabVIEW and C that demonstrate every aspect of the boards' functionality. NI motion controllers run the control loop in hardware so the examples will work for both, closed loop and open loop (stepper motor) applications.
    I hope that helps,
    Jochen Klier
    National Instruments Germany

Maybe you are looking for

  • I can no longer use my remote to access my music

    I use my remote to choose my songs on iTunes, but out of the blue yesterday it no longer works. It brings up all of my playlists but when I select one there is no music there. When I go to choose a song, album, or artist, the screen says either "Erro

  • HP Photosmart Premium 309a not printing to Printable CD

    OS = Windows XP Connection from laptop to c309a is USB Can print from MS WORD to c309a Can print from HP Solution Center application to 309a to print paper CD labels. CANNOT print from HP Solution Center application to printable CD installed in c309a

  • Is it possible to print multiple pages on a paper?

    Hi, I'm somewhat new to InDesign and am using CS6. I will describe what I would like to accomplish since I'm not sure how to ask my question. I am making a master page (A-master) for a playing card for the purpose of using data merge to fill in the t

  • Active Applications ???

    How do you know all the active applications that are running? Is there a taskbar sort of thing for leopard? Also: sometimes things are active; however, neither the expose nor does the finder have any indication of them running -- how do you get the t

  • [svn:fx-trunk] 9117: DropDownList bug fixes

    Revision: 9117 Author:   [email protected] Date:     2009-08-05 14:12:45 -0700 (Wed, 05 Aug 2009) Log Message: DropDownList bug fixes http://bugs.adobe.com/jira/browse/SDK-22536 - Spark DropDownList highlight not working as expected when navigating u