NI PCI 5102 not visible in MAX

Hi all
I've got a problem on a testrig. I use a PCI 5102 high speed digitizer to acquire a signal. Since this morning, the acquisition and processing of this signal has slowed down and now it takes twice as long as before.
What could be the cause of this problem?
During searching for a solution on the system, I found that the device is not visible in MAX. Two weeks ago, I updated the testrig to LV8.0, which means that I made a single installer - more information to this can be found in this thread:
http://forums.ni.com/ni/board/message?board.id=170&message.id=164285&view=by_date_ascending&page=1
As said, I installed this approximately two weeks ago and it ran without any problems until this morning. So I wanted to test the card in MAX so that I maybe find something, but firstly it took a relative long time to open the Items and Interfaces node and secondly there was no item in. No PCI 5102, no Fieldpoint modules, no serial ports - although I use these devices in this app.
Is this maybe related to my original problem of the massively slowed down acquisition?
Any fast answer that helps to solve the problem is really highly appreciated, as this testrig is part of a production line.
Thomas
Using LV8.0
Don't be afraid to rate a good answer...

Thomas,
I'm not sure why your 5102 measurements are slowing down, but I do have
a likely solution to your issues with MAX.  Hopefully fixing MAX
will remedy both problems.
1) Browse to C:\Program Files\National Instruments\MAX.  There is
a folder named "Data" that has the configuration info for MAX.
2) Delete the "Data" folder after making a copy on your desktop (it is
rare, but in some cases it may be useful to recover old
configurations).  If Windows won't let you delete the folder, try
ending the nimxs.exe process from task manager.  If you have any
tasks or scales saved in MAX, they will be deleted in this step.
3) Reboot your computer and open up MAX.  This will force a
refresh of all configuration information for your system, and will most
likely clear up your problems with MAX.
Please let me know if this works for you, and if this fixes the issue
with your digitizer as well.  If this doesn't help, there are
other debugging steps that we can try.
Thanks,
Travis W

Similar Messages

  • Goepel PXI-3220 not visible in MAX

    I have installed 2 goepel pxi-3220 cards into a NI PXI-chassis. But there arent visible in MAX. The drivers in the windows device manager are present and working fine. I would like to have these two cards visible in MAX. Does anyone have any experience with these analogue output cards?

    Hello,
    Only devices that were produced using the VISA driver development Wizard are viewable in MAX. If the 3rd party manufacturer did not use our driver wizard, then the device will not show up in MAX. If that is the case, the card must come with a programming API and also some sort of configuration program. It sounds as though the drivers and are installed correctly since you see them in the device manager.
    Regards,
    Andrew M
    National Instruments

  • PCI-GPIB not showing in MAX or correctly in Device Manager.

    I am having an issue with the PCI-GBIP working correctly for our setup. I have removed NI 488.2, and all associated software from the computer and have done new installs of NI 488.2 v1.7 and GPIB software.
    Configuration for the software allows me to choose the board type, and configure the board.
    When I test the board using diagnostics, I get the board as passed.
    When I open device manager, it sees the board as PCI Simple Communications Controller. MAX Does not read the card at all.
    I am using this to control an ICP-OES using WinLab32, and can get a connection, but am getting a Status Command Failed when attempting to light the plasma. There is communication, but I don't believe that it is all there.
    I have tried reinstalling multiple times, but to no avail. There is no NI-VISA on the computer, but I didn't uninstall this either. I attempted to install NI-VISA 4.2 and it stopped communicating entirely.
    Any help is greatly appreciated as I am stumped.

    Hi Joplrw10,
    Which PCI-GPIB card are you using? What OS? It sounds like you may have a driver issue. I would recommend uninstalling all the driver and reinstall according to the below links.
    Installing PCI/PCIe-GPIB Controllers
    http://www.ni.com/getting-started/set-up-hardware/instrument-control/pci-gpib
    Instrument Control in Windows with GPIB: Set-up and Configuration
    http://www.ni.com/webcast/1433/en/
    Thanks,
    Frank
    Application Engineer
    National Instruments

  • USB/directshow camera not visible in max/imaqdx

    I've got a Chameleon USB2.0 camera from Point Grey and I'm having problems getting it to show up in MAX.
    I'm running a fresh installation of labview 2012, MAX 5.3.3f2, IMAQdx 4.0, IMAQ 4.7 on a windows 7 x64 lenovo T420 laptop.
    I'm aware of the problems with registering the DirectShow filters for the Point Grey cameras:  http://digital.ni.com/public.nsf/allkb/7DF278AF77461951862579AD0063B9AD
    I've tried all of the various driver versions from Point Grey, and currently have installed the v2.4 x86 version
    The camera is visible using AMcap, a lightweight DirectShow viewer, so it seems that the camera is operational and the DirectShow interface is functional.
    I had an older version of Labview installed, and the camera was visible in MAX.  I wanted to upgrade versions but didn't use the NI update service and just downloaded the various files from the website.  About the time I upgraded MAX to 5.3 the camera disappeared from MAX.  I assumed some problem with the upgrade, so I completely uninstalled both Labview and the camera drivers and tried a fresh installation, but I still can't see the camera in MAX.
    Any ideas about how to get my camera to show up in MAX?
    Thanks!

    Did you find anything?  I have two Mightex USB cameras hooked up and believe that I might be having the same problem.  
    I can actually get both devices to show up in AMCAP, but the 2nd camera that I have hooked up to the computer doesn't show up in NI-MAX.
    I have spoken with the camera manufacturer and they have verified that these DirectShow drivers have worked on old versions of LabVIEW.  Please get back to me if you know anything regarding this error.

  • PCI-7344 not found in MAX 3.1.1 after installing NI-Motion 7.0

    Hi,
    I updated my PCI-7344 + LabView 7.0 system with the newest NI-Motion 7.0. After the update the card was not anymore detected in MAX. There was a "broken" device PCI-7344 under NI Motion Devices, which status said something like "This device has been removed or could not be detected" and the Reset command said something like "Could not communicate with the device. Power cycle the computer..". I removed the device from the "Devices and interfaces" list and since that, MAX hasn't had a clue about the card. I've tried the "Create new.." function, but it doesn't show any NI Motion Devices or PCI-7344 anywhere else. I've also tried the Tools/Install legacy driver support, but MAX only notifies that the updates are OK. I've also tried removing the physical device, starting the computer and MAX, reinstalling the device and restarting MAX, but nothing changes. The device is recognised by BIOS as "Unknown device"; in Windows 2000 Pro, the device is well recognised as National Instruments PCI-7344.
    One thing that could cause the problem is that I also have LabView 6i installed on the system, although I'm not currently using it for any purpose. Anyway, this seems to prevent the MAX from detecting the correct updates needed when using the "National Instruments Product Updates.." from Tools menu. Perhaps I need some driver software to correct this problem?
    I also tried to uninstall the NI-Motion 7.0 and to install the NI-Motion 6.1.5, but after this, the MAX did not work correctly. For example, none of the branches in the configuration tree would expand and the MAX locked up when trying to use the Create New.. / NI Motion Device. Is there a way to uninstall the NI-Motion 7.0 and to replace it with NI-Motion 6.1.5 without removing all NI software from the system?
    Before the update, with NI-Motion 6.1.5, the PCI-7344 card was correctly found in MAX and well usable in LabView 7.0.

    Jouni,
    A valid serial number is any number > 0. If you have multiple boards in you system, they must each have a unique serial number. This would be the case for any board coming out of manufacturing. The board Jochen had probably came from R&D and was a prototype board.
    Your problem with downgrading from NI-Motion 7.0 to NI-Motion 6.1.5 was most likely due to the data stored in the MAX database. When you uninstall NI-Motion, the data in the MAX database remains. The NI-Motion 6.1.5 driver would not have been able to read the data correctly. The easiest way to "clear" this database is to delete the c:\Program Files\National Instruments\MAX\data folder. The only other way is to uninstall MAX, which requires that you uninstall everything. WARNING, Deleting the MAX data folder will delete all MAX settings and set them back to defaults for all NI hardware (uninstalling everything has this same affect, by the way). Downgrading is never as clean as upgrading.
    The firmware on a Motion board can always be downgraded by forcing the download of firmware files. To do this, select the board in MAX under Devices and Interfaces. Click on the Firmware tab at the bottom on the window. Highlight "PCI-73XX Firmware" by clicking on it once. Right click on one of the items in the "Firmware name" column to the right. Select "Download All Files".
    I do not have a good explaination for why NI-Motion 7.0 did not recognize your board. Do you have a second board you can try in the system? If not, could you ask your local sales representative if they have one you borrow for a quick test? Since the board is recognized by Windows 2000 Device Manager, I don't think there is an issue with the board, but it doesn't hurt verify this.
    My best guess is that there was a confict during the installation process and your system did not get all of the required files. Though we do significant installer testing, there are rare occasions when a system is in such a state that the installation process does not function as expected. It is my experience that these rare instances do not occur on clean machines, but on machines that have had multiple products installed and uninstalled. If you do get a chance to try NI-Motion 7.0 again you may want to use these parameters to get the installer to create a log of the installation: "c:\setup.exe l*v c:\log.txt". This assumes that the setup.exe is in the c:\ directory. Go to start>>run and type this in without the quotes. The log file will be named log.txt in the c:\ directory.
    Finally, you can technically use NI-Motion 7.0 in LabVIEW 6. You just need to copy the C:\Program Files\National Instruments\LabVIEW 7.0\vi.lib\Motion folder to the vi.lib folder of LabVIEW 6. Though this is not officially supported, there is no reason it shouldn't work.
    Regards,

  • MXI not visible in MAX

    I have installed the MXI Express x1 kit in my PXI 1050. The computer doesn't boot. I disconnect the cable from the PXI rack and the PC boots. Looking through the forum I find a common thread about the MXI killing the PC boot. But I am not finding the BOOT-FIX, or the BOOT-Work-Around mentioned in the posts. The biggest curiosity is why the PCI card doesn't show up in the NI-Max inventory. Some of the dialog talks about "bus-mastering" another curiosity. Is this bus-mastering "Slot Specific" on the PC mother board? I remember back in the "old" PC days some options were not available except in the "first" slot. I inventoried the mother board and am posting the stats. I submitted a direct question to the engineering staff at NI. And with no answer in the first 24 hours, I am scouring the forum for any hint of a solution. We have burned up - fried - beat to death. 5 controllers in the last year. the bone yard is empty. How do I make this work?  and thank you for your help...
    Asus UEFI Bios Version 9901 x64 build date  02/28/2012
    EC version  MBECD-0006a
    ME version  8.0.0.1351
    South Bridge Stepping  B3
    CPU Intel Core i5-2500k @ 3.3GHz
    Speed 3300 MHz
    Memory 4096 (DDR3)
    Mem Freq 13333 MHz
    EM64T  supported
    Processor Stepping 206a7
    Microcode Rev  25
    Processor Cores 4
    Windows 7 Professional  32Bit  SP1

    I am having trouble with my devices working in my executable code.  The code was provided by our test development department back in 2004. The errors are popup windows telling me the card didn't initialize. These cards are being called using DAQmx. I have nothing in my NI-MAX showing up as DAQmx. What is happening ?
    // Initialisieren der SCXI-1104  iResult = DAQmxScxi1104_Voltage(&Scxi1104TaskHandle_global);                                           CHK_TESTER_ERROR(ERROR_SCXI_1104_INIT)  iResult = DAQmxStartTask(Scxi1104TaskHandle_global);                                                      CHK_TESTER_ERROR(ERROR_SCXI_1104_MEASUREMENT)
      // Initialisieren der PXI-6052E AnalogOutputCH0  iResult = DAQmxPxi6052E_AnalogOutputCH0(&Pxi6052ETaskHandleAnalogOutputCH0_global);                             CHK_TESTER_ERROR(ERROR_MIO_6052E_INIT)  iResult = DAQmxStartTask(Pxi6052ETaskHandleAnalogOutputCH0_global);                                             CHK_TESTER_ERROR(ERROR_MIO_6052E_CONFIGURATION)  // Initialisieren der PXI-6052E AnalogOutputCH1  iResult = DAQmxPxi6052E_AnalogOutputCH1(&Pxi6052ETaskHandleAnalogOutputCH1_global);                             CHK_TESTER_ERROR(ERROR_MIO_6052E_INIT)  iResult = DAQmxStartTask(Pxi6052ETaskHandleAnalogOutputCH1_global);                                             CHK_TESTER_ERROR(ERROR_MIO_6052E_CONFIGURATION)
    // Konfigurieren der SCXI-1127 auf Independant  sprintf(sRessourceScxiSwitch, "SC%dMod%d", iAdrChassis1_global, iAdrMatrix1_global);  iResult = DAQmxSwitchSetTopologyAndReset(sRessourceScxiSwitch, DAQmx_Val_Switch_Topology_1127_Independent);   CHK_TESTER_ERROR(ERROR_SCXI_1127_INIT)
    Attachments:
    SUT_SequencerFunctions.c ‏107 KB
    scxi4.jpg ‏53 KB

  • IEEE 1394 Camera Not Visible in MAX

    Problem Description :
    I'm using the following hardware:
    1. Texas Instrument OHCI Compliant IEEE 1394 Card ( Ratoc PCIFU2)
    2. Basler 601f Camera ( NI certified)
    (DCAM v.1.20 compliant)
    Sofware :
    1. LabView 7.0
    2. Max 3.0
    3. NI IMAQ for IEEE -1394 Ver 1.5
    4. Vision Development MOdule 7.0
    I am able to use the camera via Vision Assitant (7.0), but unable to see
    the
    camera listed in MAX. I have tried all the steps listed in FAQs.The driver
    for
    the camera is 1394imaq (i.e. all this has been checked).
    I can run the 1394-Imaq vis & acquire images as well, but like i said no
    camera listed in max ....
    NI Software : LabVIEW version 7.0
    NI Hardware : Other device
    Driver Version :
    OS : Windows 2000
    Customer Info
    rmation :
    MK
    [email protected]

    Hello,
    It looks like the MAX provider for NI-IMAQ 1394 may have been corrupted. This can usually be fixed by running a repair on the installer. You can do this by running the installer from Add/Remove Programs.
    Hope this helps!
    Best Regards,
    Yusuf C.
    Applications Engineering
    National Instruments

  • Properties not Visible in MAX

    I'm working on a PC that isn't connected to the Internet so it may be an old version of MAX.
    I have a NI-2627 switch that I need to change the topology of from 32x2 to 64x1. When I open MAX and right-click on the card, the only options I get are: Save, Rename Alias, Delete (greyed out), and Open VISA Test Panel.
    Version is 4.6.2f1
    How do I change the topology of the switch if I can't get to it in MAX? Thanks.

    Hello Erin,
    Welcome to the NI Discussion Forums! Like you said, there should be an option called “Configure” in MAX when you right click on the card.
    However, please remember than you can configure it programmatically with the “niSwitch Initialize with Topology.vi”
    I Hope this helps.
    Regards,
    Daniel REDS
    RF Systems Engineer
    Help us grow.
    If a post solves your question, mark it as The Solution.
    If a post helps, give Kudos to it.

  • PXI - DAQmx tasks will not export to MAX 5.4

    I am in the process of upgrading a PXI 1050 with an 8176 to an MXI bridge. The latest headache is that the CVI program had several DAQmx (tasks) defined in MAX 3.1.1 which will not export to MAX 5.4. I have been posting these additional questions on my original thread MXI not visible in MAX. I have many tasks for installed PXI cards. I was trying to make simple tasks just defining these cards to change the errors I receive in CVI. I do not have the option to define a task for some of these cards like the 4070 DMM. I did not generate the original CVI code. I am not sure what is defined the DAQmx. Can someone provide some insight ? I have viewed the suggested videos and white paper links. They were instructive but of little help.

    Unfortunately; no updates without dollars. While we all work for the same company, we must contract work between departments. There was no defect with the software as delivered. Old age crept in to the hardware. Any upgraded hardware, it turns out,  requires updating of the software. The unit had operated reasonably well, until a couple years ago. An unfortunate selection of network security software caused massive headaches. The software chosen assumed a more advanced level of hardware. Mandatory installation on all network computers rendered these controller inoperable. Our local IT guys shaved down the install to minimal components but the controller lost all available ram to this software, NI-MAX requires 20 minutes to build it's database on reboot. The computer controllers struggle to function. They periodically get lost and require a reboot, causing 30 minutes or more to restart. This is driving a replacement. We decided that it would be more cost effective to move to a standard computer interface. With the MXI, we could have a much more friendly and versatile interface. The upgrade is with a different "color" of corporate money. There isn't enough funding to contract a software upgrade. It is feasible to complete the upgrade in house, once we can identify the players and their function. Second we need the necessary time and access to the equipment. I do not have the ability to expend too many extra hours at work. So it takes time. I have been able to piece together the following. In the development stage back in 2004 - 2005, the developers used both Traditional DAQ and DAQmx. They build tasks for the SCXI in CVI. They have toolboxes making calls to Traditional DAQ. Also at some point in time they must have used the option in 3.1.1 to Convert Traditional NI-DAQ(Legacy)Configuration to NI-DAQmx, which built all the extra DAQmx devices we see in the device tree in the MAX 3.1.1. So beyound the errors there appears to be a few red herrings, just for fun. So there is no tasks to convert from 3.1.1, everything is contained in the CVI code. I have to find a way to use the CVI debugger to lead me to the nested, buried code causing the errors, and simply correct them. Just for another layer of complexity, they are probably logic errors, not syntax errors, or updated code errors where the legacy code no longer functions with the updated drivers. Or, hey, it could be the beta version of NI-DAQ, because it is the only one working with Windows 7 (32).

  • PCI 7330 not recognized in Windows 7

    When I transferred my 7330 motion controller board to another PC, it is not recognized in MAX. Windows system put it as unknown PCI board. 
    The PC runs on Windows 7. LabVIEW 2010 and MAX 4.7 were installed. What could be the reason for the 7330 not being recognized?
    Thanks.

    Yes, I found out why. When I install the device drivers, I always install the default selected drivers. So it must be that NI-Motion driver is not included in those defaults. The second time, I specifically selected to install NI-Motion;now the board is recognized well. 
    It's trivial, but another thing learned. Thanks for the reply. I also posted this on the hardware forum. 

  • Data in CSV uploads successfully, but it is not visible after upload.

    Hi,
    I am using Apex 3.2 on Oracle 11g.
    This is an imported application for which I am making changes as per my requirements. As I am new to Apex and even SQL, I request forum members to help me with this.
    Please find below the old code for uploading data from CSV. It displays only 6 columns - Database Name, Server Name, Application Name, Application Provider, Critical, Remarks. This was successfully uploading all the data from CSV and that data was visible after upload.
    OLD CODE:_
    --PLSQL code for uploading application details
    DECLARE
    v_blob_data      BLOB;
    v_blob_len      NUMBER;
    v_position      NUMBER;
    v_raw_chunk      RAW(10000);
    v_char           CHAR(1);
    c_chunk_len           NUMBER:= 1;
    v_line           VARCHAR2 (32767):= NULL;
    v_data_array      wwv_flow_global.vc_arr2;
    v_rows           NUMBER;
    v_count           NUMBER;
    v_dbid           NUMBER;
    v_serverid           NUMBER;
    v_sr_no          NUMBER:=1;
    v_last_char          varchar2(2);
    BEGIN
    -- Read data from wwv_flow_files
    SELECT blob_content INTO v_blob_data FROM wwv_flow_files
    WHERE last_updated = (SELECT MAX(last_updated) FROM wwv_flow_files WHERE UPDATED_BY = :APP_USER)
    AND id = (SELECT MAX(id) FROM wwv_flow_files WHERE updated_by = :APP_USER);
    v_blob_len := dbms_lob.getlength(v_blob_data);
    v_position := 1;
    -- For removing the first line
    WHILE ( v_position <= v_blob_len )
    LOOP
    v_raw_chunk := dbms_lob.substr(v_blob_data,c_chunk_len,v_position);
    v_char := chr(hex_to_decimal(rawtohex(v_raw_chunk)));
    v_position := v_position + c_chunk_len;
    -- When a whole line is retrieved
    IF v_char = CHR(10) THEN
    EXIT;
    END IF;
    END LOOP;
    -- Read and convert binary to char
    WHILE ( v_position <= v_blob_len )
    LOOP
    v_raw_chunk := dbms_lob.substr(v_blob_data,c_chunk_len,v_position);
    v_char := chr(hex_to_decimal(rawtohex(v_raw_chunk)));
    v_line := v_line || v_char;
    v_position := v_position + c_chunk_len;
    -- When a whole line is retrieved
    IF v_char = CHR(10) THEN
    --removing the new line character added in the end
    v_line := substr(v_line, 1, length(v_line)-2);
    --removing the double quotes
    v_line := REPLACE (v_line, '"', '');
    --checking the absense of data in the end
    v_last_char:= substr(v_line,length(v_line),1);
    IF v_last_char = CHR(44) THEN
         v_line :=v_line||'-';
    END IF;
    -- Convert each column separated by , into array of data
    v_data_array := wwv_flow_utilities.string_to_table (v_line, ',');
    -- Insert data into target tables
    SELECT SERVERID into v_serverid FROM REPOS_SERVERS WHERE SERVERNAME=v_data_array(2);
    SELECT DBID into v_dbid FROM REPOS_DATABASES WHERE DBNAME=v_data_array(1) AND SERVERID=v_serverid;
    --Checking whether the data already exist
    SELECT COUNT(APPID) INTO v_count FROM REPOS_APPLICATIONS WHERE DBID=v_dbid AND APPNAME=v_data_array(1);
    IF v_count = 0 THEN
    EXECUTE IMMEDIATE 'INSERT INTO
    REPOS_APPLICATIONS (APPID,APPNAME,APP_PROVIDER,DBID,SERVERID,CRITICAL,LAST_UPDATE_BY,LAST_UPDATE_DATE,REMARKS) VALUES(:1,:2,:3,:4,:5,:6,:7,:8,:9)'
    USING
    APP_ID_SEQ.NEXTVAL,
    v_data_array(3),
    v_data_array(4),
    v_dbid,
    v_serverid,
    v_data_array(5),
    v_data_array(6),
    v_data_array(7),
    v_data_array(8);
    END IF;
    -- Clearing out the previous line
    v_line := NULL;
    END IF;
    END LOOP;
    END;
    ==============================================================================================================================
    Please find below the new code (which I modified as per my requirements) for uploading data from CSV. It displays 17 columns - Hostname, IP Address, Env Type, Env Num, Env Name, Application, Application Component, Notes, Cluster , Load Balanced, Business User Access Mechanism for Application, Env Owner, Controlled Environment, SSO Enabled, ADSI / LDAP / External Directory Authentication, Disaster Recovery Solution in Place, Interfaces with other application.
    This is successfully uploading all the data from CSV, But this uploaded data is not visible in its respective tab.
    _*NEW CODE:*_
    --PLSQL code for uploading application details
    DECLARE
    v_blob_data      BLOB;
    v_blob_len      NUMBER;
    v_position      NUMBER;
    v_raw_chunk      RAW(10000);
    v_char           CHAR(1);
    c_chunk_len           NUMBER:= 1;
    v_line           VARCHAR2 (32767):= NULL;
    v_data_array      wwv_flow_global.vc_arr2;
    v_rows           NUMBER;
    v_count           NUMBER;
    v_dbid           NUMBER;
    v_serverid           NUMBER;
    v_sr_no          NUMBER:=1;
    v_last_char          varchar2(2);
    BEGIN
    -- Read data from wwv_flow_files
    SELECT blob_content INTO v_blob_data FROM wwv_flow_files
    WHERE last_updated = (SELECT MAX(last_updated) FROM wwv_flow_files WHERE UPDATED_BY = :APP_USER)
    AND id = (SELECT MAX(id) FROM wwv_flow_files WHERE updated_by = :APP_USER);
    v_blob_len := dbms_lob.getlength(v_blob_data);
    v_position := 1;
    -- For removing the first line
    WHILE ( v_position <= v_blob_len )
    LOOP
    v_raw_chunk := dbms_lob.substr(v_blob_data,c_chunk_len,v_position);
    v_char := chr(hex_to_decimal(rawtohex(v_raw_chunk)));
    v_position := v_position + c_chunk_len;
    -- When a whole line is retrieved
    IF v_char = CHR(10) THEN
    EXIT;
    END IF;
    END LOOP;
    -- Read and convert binary to char
    WHILE ( v_position <= v_blob_len )
    LOOP
    v_raw_chunk := dbms_lob.substr(v_blob_data,c_chunk_len,v_position);
    v_char := chr(hex_to_decimal(rawtohex(v_raw_chunk)));
    v_line := v_line || v_char;
    v_position := v_position + c_chunk_len;
    -- When a whole line is retrieved
    IF v_char = CHR(10) THEN
    --removing the new line character added in the end
    v_line := substr(v_line, 1, length(v_line)-2);
    --removing the double quotes
    v_line := REPLACE (v_line, '"', '');
    --checking the absense of data in the end
    v_last_char:= substr(v_line,length(v_line),1);
    IF v_last_char = CHR(44) THEN
         v_line :=v_line||'-';
    END IF;
    -- Convert each column separated by , into array of data
    v_data_array := wwv_flow_utilities.string_to_table (v_line, ',');
    -- Insert data into target tables
    --SELECT SERVERID into v_serverid FROM REPOS_SERVERS WHERE SERVERNAME=v_data_array(2);
    --SELECT DBID into v_dbid FROM REPOS_DATABASES WHERE DBNAME=v_data_array(1) AND SERVERID=v_serverid;
    --Checking whether the data already exist
    --SELECT COUNT(APPID) INTO v_count FROM REPOS_APPLICATIONS WHERE DBID=v_dbid AND APPNAME=v_data_array(1);
    IF v_count = 0 THEN
    EXECUTE IMMEDIATE 'INSERT INTO
    REPOS_APPLICATIONS (APPID,HOSTNAME,IPADDRESS,ENV_TYPE,ENV_NUM,ENV_NAME,APPLICATION,APPLICATION_COMPONENT,NOTES,CLSTR,LOAD_BALANCED,BUSINESS,ENV_OWNER,CONTROLLED,SSO_ENABLED,ADSI,DISASTER,INTERFACES) VALUES(:1,:2,:3,:4,:5,:6,:7,:8,:9,:10,:11,:12,:13,:14,:15,:16,:17,:18)'
    USING
    APP_ID_SEQ.NEXTVAL,
    v_data_array(1),
    v_data_array(2),
    v_data_array(3),
    v_data_array(4),
    v_data_array(5),
    v_data_array(6),
    v_data_array(7),
    v_data_array(8),
    v_data_array(9),
    v_data_array(10),
    v_data_array(11),
    v_data_array(12),
    v_data_array(13),
    v_data_array(14),
    v_data_array(15),
    v_data_array(16),
    v_data_array(17);
    END IF;
    -- Clearing out the previous line
    v_line := NULL;
    END IF;
    END LOOP;
    END;
    ============================================================================================================================
    FYI, CREATE TABLE_ is as below:
    CREATE TABLE "REPOS_APPLICATIONS"
    (     "APPID" NUMBER,
         "APPNAME" VARCHAR2(50),
         "APP_PROVIDER" VARCHAR2(50),
         "DBID" NUMBER,
         "CRITICAL" VARCHAR2(3),
         "REMARKS" VARCHAR2(255),
         "LAST_UPDATE_DATE" TIMESTAMP (6) DEFAULT SYSDATE NOT NULL ENABLE,
         "LAST_UPDATE_BY" VARCHAR2(10),
         "SERVERID" NUMBER,
         "HOSTNAME" VARCHAR2(20),
         "IPADDRESS" VARCHAR2(16),
         "ENV_TYPE" VARCHAR2(20),
         "ENV_NUM" VARCHAR2(20),
         "ENV_NAME" VARCHAR2(50),
         "APPLICATION" VARCHAR2(50),
         "APPLICATION_COMPONENT" VARCHAR2(50),
         "NOTES" VARCHAR2(255),
         "CLSTR" VARCHAR2(20),
         "LOAD_BALANCED" VARCHAR2(20),
         "BUSINESS" VARCHAR2(255),
         "ENV_OWNER" VARCHAR2(20),
         "CONTROLLED" VARCHAR2(20),
         "SSO_ENABLED" VARCHAR2(20),
         "ADSI" VARCHAR2(20),
         "DISASTER" VARCHAR2(50),
         "INTERFACES" VARCHAR2(50),
         CONSTRAINT "REPOS_APPLICATIONS_PK" PRIMARY KEY ("APPID") ENABLE
    ALTER TABLE "REPOS_APPLICATIONS" ADD CONSTRAINT "REPOS_APPLICATIONS_R01" FOREIGN KEY ("DBID")
         REFERENCES "REPOS_DATABASES" ("DBID") ENABLE
    ALTER TABLE "REPOS_APPLICATIONS" ADD CONSTRAINT "REPOS_APPLICATIONS_R02" FOREIGN KEY ("SERVERID")
         REFERENCES "REPOS_SERVERS" ("SERVERID") ENABLE
    ==============================================================================================================================
    It would be of great help if someone can help me to resolve this issue with uploading data from CSV.
    Thanks & Regards
    Sharath

    Hi,
    You can see the installed dictionaries and change between them by right-clicking and choosing '''Languages''' inside a live text box eg. the box you are in when replying or right-clicking on the '''Search''' box on the top right corner of this page and choosing '''Check Spelling'''.

  • No GPIB connection, but visible in MAX

    The device is visible in MAX, but I am unable to communicate with it, either by using the 'Communicate with Instrument' or the 'VISA Test Panel'.
    This seems slightly sporadic, as I have once or twice been able to connect and send a successful ID query (It's too old for *IDN? ...). However, even if I reach this point I either then get error 0: not able to connect to device/driver or error 6: timeout within Labview, and then I am unable to do anything in MAX after that point.
    I have tried disabling timeout, switching cables, turning everything off and on again all to no avail.
    This is very frustrating as with my standard setup I have not changed any VI's, settings, cables or anything since it was working fine earlier.
    Cheers for any input. 

    Sure, I'll see what I can find and if it helps at all.
    Interestingly, today the 5210 connected fine and I was able to test some new code and everything worked perfectly...

  • Xcelsius - Embedded 'Jpg' logo not visible, Pie chart Legends not visible

    Hi,
       I am new to xcelsius. could you please help.
       I have two issues.
      1. I incorporated Logo (JPG FILE) and selected options Embed file, resize image to component, but image is not visible when I preview. Why? What needs to be done to make logo visible in preview(swf file). I did not export yet to Infoview though.
    2. Legend values are cropped. I have 35 legends that are to be listed for pie chart. I can see only 31 and remaining four not visible (two from beginning, 2 at the end). I reduced font to lowest visible value i.e.  8 and increased height max possible that looks good . How to make them visible? or make them to fit to chart. Is there any option? Legend values are towards right of chart.
    Please help.
    BR, Nanda Kishore

    Hi,
       Are you using Image Component to insert your JPEG, if not try that. It will work as expected.
       As for your pie chart legends, it will work as long as your Pie Chart is large enough to fit all regions onto the screen.
       Try a simple test just to prove that concept.
          - Create 2 columns in Excel
          - Make Column A your Region Column. Insert up to 35 records
          - Make Column B you Data column. Also insert up to 35 records.
          - Now map your data into the Pie Chart and make sure you reduce the fonts of the region to "8" (Smallest it can go)
          - Preview it.
    Ken

  • PCI-6014 not recognized by Windows 2000

    I recently purchased and just installed a PCI-6014 in a new Dell Optiplex running Windows 2000 (sp2, we have stayed at sp2 due to problems we have had with sp3, sp4). On this same machine I have LabVIEW 7.0 with all the bells, including NI-DAQ 7.0. When I put the pci card in for the first time (and every one of many times I have restarted since) I NEVER have seen the "new hardware found" message come up. That's bad sign one. And the hardware device manager doesn't see it either (I think that would follow from no new hardware being detected..) Then I have run MAX 3.0 (also on the machine) and all it finds is this bizarre thing called "PXI System" under devices and interfaces. I also have an eight port serial card in this machine which MAX does see. I eventually removed both the Serial card and the PCI-6014 (daq card) and even after a restart the "PXI system" device or whatever STILL shows up under devices and interfaces... So I just don't know what that is?? Any help there would be appreciated.. So question one is what is "PXI system" likely referring to?? ..And to say more about it when you click the plus sign next to the "PXI system" entry it shows what appears to be a VISA resource name of PXIO::MEMACC. But again that shows up even with the card removed.
    Back to the PCI card seemingly not being recognized I also read somewhere that there could be issues with this card and the new version of NI-DAQ 7.0. So I uninstalled that version from the machine and put on the version that came with the PCI card, NI-DAQ 6.9.3. But same story... Windows doesn't see it and unless this PXI system is somehow referring to this PCI card (??) then MAX doesn't seem to be seeing it either... Any advice on how to get this card up and running or how to truly troubleshoot to see if the card was dead out of the box?? ...Something I have never had happen before and somehow I still think it is just some silliness on my part...
    Lastly, when I looked for the documentation for this card amont the long, long list of daq boards listed in the NI-DAQ software, nowhere did I find an entry for this PCI-6014 card. And I looked carefully. Does that mean I have a horribly old or outdated card??
    Any help would be appreciated... thanks...

    I am glad to hear that you got your card recognized correctly, too bad you have some bad PCI slots, though. The entry is shown by default and cannot be removed, but if you were to ever have a PXI chassis attached, your cards would be listed under this option, it is also where you would configure your controller and your chassis type. Also by default, there are no entries under this heading since you are not connected to a PXI system.
    Andrew Mierau
    Applications Engineer
    National Instruments

  • Visa server security tab not visible

    I want to enable the visa server for remote visa connections to the serial port, when I go into MAX to setup the visa server security the tab is not visible. I have a 2nd system and I can see the tab. Is some setting needed to enable the security?

    Hello Chris,
    I would expect that this is because of a version difference in your two machines. What OS are they? What version of VISA are they using? You can see the VISA version in MAX under the software folder. Also, to clarify, are you speaking about the "VISA Options" tab that appears when you select NI-VISA from the software folder, or something else?
    If you need to download a newer version of VISA, see here for all VISA versions:
    http://digital.ni.com/softlib.nsf/webcategories/85256410006C055586256BAC002C51FA?opendocument&node=132070_US
    Hope this helps.
    Scott B.
    Applications Engineer
    National Instruments

Maybe you are looking for

  • ASA Service Module on 6500 montoring console session

    We have 6500 with ASA Service Module On 6500 how can we configure so that if someone logs in to the ASA Service Module and reboots the firewall we can have logs of it in syslog of switch . Thanks for help

  • Question marks and slideshow now working

    I am have the same problem with question marks, lines going through the photos and the slideshow option won't work. I did see someone mentioned republishing. I will try that. Are others having the same problems.

  • ORA-00904 coming because of  table JOIN

    I have this query which works fine, how everwhen I attempt to join the pubsched table based on schedules.areaid = pubsched.areaid it comes up with ORA-00904 telling me that the area id is invalid. Try commenting out line 8 of the query which joins th

  • App for editing microsoft word documents

    I am a PhD student in the area of engineering sciences and I frequently need to write journal articles which are mathematically involved. I am just wondering if there are any word editing apps on iPad which can recognize mathtype equations? I purchas

  • Satellite A300 - Cannot use WLan

    Hi I have a Toshiba Laptop A300 and did a reboot / clean laptop with rescue disk from Toshiba Vista Home 32 bit x86 All went fine with reinstall + vista SP 1 + office ... But no wireless Lan possible / via cable I have internet. Following steps follo