NI PCI 6731 with DASYLab

Hello Dasylabers,
I use a NI PCI 6731 to do waveform generation with DASYLab 11, which works
correctly.
But this card is able to
have an external reference signal (AO EXT REF) for the digital to analog
converter.
How is it possible to
active this function for each converter (there is 4) in MAX or
DASYLab?
Thank you in advance for your help!
Frédéric Miqueau
MD Electronic, France
http://www.mdelectronic.fr
French Dasylab Forum : http://www.dasylab-forum.de/forum/index.php?showforum=43
Solved!
Go to Solution.

Hello Mathias,
I've tried to modify with Labview a MAX task and save it. I have this result:
Not modified MAX task:
Task modified with Labview and saved in MAX:
It seems to work, but I have not the hardware to test the result in Dasylab. I use simulated hardware.
Sure that this possibility should be add in MAX task configurator, so Dasylab could use all the hardware functions!
How can I contact NI-DAQmx developers?
Where are the ressources for NI-DAQmx API functions?
Thank you for your help,
Frédéric Miqueau
MD Electronic, France
http://www.mdelectronic.fr
French Dasylab Forum : http://www.dasylab-forum.de/forum/index.php?showforum=43

Similar Messages

  • Satellite A500-1GH What is a empty PCI slot with JGPS sign

    Almost a year ago I bought a Toshiba Satellite A500-1GH.
    I cannot say that I am not satisfied with the computer or the company.
    The problems that I had was the Display problem (stop working for seconds) which was software problem (updated nVidia 8.16.11.8875) and with the HDD which stop working but company changed with a new one.
    Now I wanted to upgrade the second memory module from 2GB to 4GB so I can have 2x4GB, but when I opened the memory compartment, I saw next to them an empty PCI slot with the sign JGPS.
    Does anybody know what that is?
    And if yes what is the part number?
    Thank you in advance.

    Hi mate
    As far as I know JGPS is an GPS connector.
    Possibly this connector would be shared by 3G miniPCI card.
    As far as I know this Satellite A500-1GH has not been equipped with an 3G module and therefore the miniPCI slot is empty.
    > And if yes what is the part number?
    I don't know the part number but all parts can be ordered from local Toshiba ASP

  • Can I use a DAQ PCI-1200 with Labview 5.0.1?

    I have a Labview 5.0.1 software, and I want to use PCI-1200 with it. Can I do that? My OS is Windows XP, but I can change it with Windows98/2000.

    Hello jhylee,
    The latest NI-DAQ driver for the PCI-1200 is 6.9.3, which is compatible with LabVIEW 5.0.1. LabVIEW 5.0.1 supports Windows 2000, but not Windows XP (although it may still run).
    Have a nice day!
    Robert M
    Applications Engineer
    National Instruments
    Robert Mortensen
    Software Engineer
    National Instruments

  • How to visualise continues Data aquisition from a PCI 6602 with 2121 BNC connector board in C++ ?

    Hello everyone,
    We are trying to get on the screen the aquired pulses from our  PCI 6602 with a 2121 BNC connector board, from several devices. We are able to read the data and save without problem, but we cannot look at it while we are measuring. Anybody has an idea to how program this in C++ ? Any suggestion is welcome!
    Thanks for the help

    Hi,
    try to look for some example programs and Tutorials:
    Examples Results
    http://search.ni.com/nisearch/app/main/p/bot/no/ap/tech/lang/en/pg/1/sn/catnav:ex/q/DAQmx%20C%2B%2B/...
    Tutorials Results
    http://search.ni.com/nisearch/app/main/p/bot/no/ap/tech/lang/en/pg/1/sn/catnav:tu/q/DAQmx%20C%2B%2B/...
    You should also have a look at the "C Reference Help" which is installed with the NI DAQmx driver.
    Acquire N Scans (Visual C++ 6.0, CW++, NI-DAQ)
    http://zone.ni.com/devzone/cda/epd/p/id/207
    Continuous Analog Acquisition with Producer Consumer Architecture in C#
    https://decibel.ni.com/content/docs/DOC-4253
    Good Luck!
    Matteo

  • Is Ardence RTX required when I use PCI-7831R with labview real-time module for RTX target

    I am new in the labview real-time field. I want to use labview real-time module for RTX target on only one desktop. My card is PCI-78331R.  Is Ardence RTX necessary? Why I cannot find my card in the MAX after I configured the RTX?
    Thank you very much.

    Hi Ziaozhongda,
    You must have the RTX runtime engine installed before the LabVIEW Real-Time RTX module will install.  Additionally, you should follow the instructions in the "Using the NI PCI-7831R with the LabVIEW Real-Time Module for RTX" section of Getting Started with the NI 7831R (page 8).
    Please see Configuring Hardware for Use with RTX.
    Also useful is "How Can I Validate That My PC Will Run RTX?

  • NI-scope PCI-5105 with 2 triggers

    Hello,
    I have a similar problem like in the post of NI-scope PCI-5124 with 2 triggers. http://forums.ni.com/t5/High-Speed-Digitizers/NI-scope-PCI-5124-with-2-triggers/m-p/1132555/highligh...
    I tried to use this code with my PCI-5105 NI-scope card, but I wasn't able to get it to run using an analog trigger to start the recording.
    What do I have to pay attention to make my input signals acceptable as start trigger source?
    Thank you,
    Philipp

    Hi Philip,
    You cannot use an analog trigger as a start trigger.  If you look at the NI High-Speed Digitizers Help file you can see what types are supported for kind of trigger.  You can get to this help file in LabVIEW or by navigating to the Windows Start Menu and selecting All Programs >> National Instruments >> NI-SCOPE >> Documentation >> NI High Speed Digitizers Help file.  To get to the page talking about supported trigger types within the help file expand Fundamentals and then select Triggering.  Hopefully this helps!
    Josh B
    Applications Engineer
    National Instruments

  • PCIe-1433 with camera MC1362 (Mikrotron)

    Hello,
    I would like to use my camera MC1362 (Mikrotron) with the frame grabber PCIe-1433. But this camera is not yet suported by NI, so I don't have any camera file for this camera. I tried to use the one done for the MC1310 (I have seen people on this forum who had used it with the frame grabber PCIe-1429 with success), but it didn't work too. I tried then to make a camera file with the camera file generator provided by NI, it didn't work too (no error message, but no image also!).
    does anybody have successfully made a camera file for this camera and this frame grabber? Is it possible to obtain one from NI engineers, please?
    Thank you in advance,
    Bests

    I just put a new Camera File Generator on the FTP site, which fixes some issues earlier versions had with the 1433. I would try this again to see if this works any better.
    ftp://ftp.ni.com/support/imaq/pc/ni-imaq/cfgenerator/2.0.6/
    If this doesn't work, we could help you develop a camera file. If you could provide your contact at Mikrotron, I could try to get a loaner camera to develop the camera file for it.
    Thanks,
    Brad

  • How can i write a pattern to a output port of NI PCI 6503 with Traditional NI DAQ 7.0 and Visual Basic 6.0?

    Hello, i'm using a NI PCI-6503 (with CB50LP accesory) to write digital patterns to one of the output ports. Can i do it directly from NIDAQ7.0?
    I know  some Visual Basic 6.0 functions to configure a par as output and to write a pattern to a port, but i don't know how run it.
    I've read some examples from "Help" (C:\Program Files\National Instruments\NI-DAQ\Examples\VBasic\Do) but I can't measuring TTL levels on my CB50LP accesory.
                    Thanks!!

    Hello,
    What is your buffer size ? The buffer should be 0 or greater than 2. You can get this error if your buffer size is equal to 1.
    Regards,
    Isabelle
    National Instruments France
    Isabelle
    Ingénieur d'applications
    National Instruments France

  • ATA PCI card with 48 bit BIOS support?

    Hello,
    I have an iMac G3 CRT purchased at the very end of 2001 (last of this model.) I am about to install a new hard drive. I am replacing an 80GB with a 160GB Maxtor (because they were the same price!) The drive box says that drives larger than 137GB require a Mac-compatible ATA PCI card with 48 bit BIOS support. Do I already have this? Is this part of the mother board? If not I will exchange the drive for a smaller one.
    Thanks.
    iMac G3 CRT Mac OS 9.2.x

    I forgot to mention something. Firewire cases can allow you to make use of a larger drive though. So you could keep your internal and put the new drive in a firewire case that supports large drives and get lots of extra space.

  • I want to interface PCI-6601 with photoelectric sensors to count the number of PCB chassis.

    I want to interface PCI-6601 with photoelectric sensors to count the number of PCB chassis. Related this I have following problems-1)Where I can connect sensors(pin numbers)?
    2)How I can acquire data from that sensors(Is is necessary to write any program? If yes, what?)
    3)In which format I will get the output data?

    Hi,
    We're going to need a little more info about your application before we can get you a compete answer.
    Your 6601 is a counter/timer board that can count and measure TTL pulses.
    You can get the pinout for your board from the user manual found here: http://digital.ni.com/manuals.nsf/websearch/dd0dbb6404bc139886256721007cf16d
    In LabVIEW, you can find shipping examples for various counter measurements by going to Help >> Find Examples >> Hardware Input and Output >> DAQmx >> Counter Measurments.
    I would also suggest downloading and installing the latest NI-DAQ driver:
    http://digital.ni.com/softlib.nsf/websearch/90B60D5899BCCCDB86256FC700581B89?opendocument&node=132050_US
    -Sal

  • Pulse patterns with 512us repetition cycle through PCI 7811 with compac RIO

    Can we generate specific pulse pattern of 15 to 30 pulses (500KHz frequency and 0.5us pulse width and patterns are transmitted repetedly with 512us interval) using PCI 7811 with compac RIO. I am having hardware but donot find any help in this regard. If some body send a small vi. for help. I shall be really thankful
    Yours sincerely 
    Solved!
    Go to Solution.

    Here's a VI I put together quickly that outputs a fixed pattern. It's barely tested, but it does compile on FPGA. Outputting more than one pattern will require more code, especially since all arrays in FPGA must be fixed-length. If you need to do multiple patterns, and I'm guessing that you do based on your other forum thread, I would look into using a memory block. I am assuming here that the output during the interval between patterns is equivalent to filling that time with false values (no pulse). If that is not the case then you will need to explain what the output should be during that period.
    However, if I've correctly understood that the false case is equivalent to no pulses, then it will be easier to use the digital hardware from your other thread instead of FPGA to do this. Just write a pattern that is 512us long - extend your digital pattern with false values to make it the full 512us period.
    EDIT: There are a couple of logic errors in this code.  It should count to 255, not 1023, and the pattern isn't right on the first iteration. I hope it's enough to get you started, though.
    Attachments:
    FPGA test.vi ‏36 KB

  • Agilent 34970 with Dasylab

    Hi
    Does anyone Know Is it possible for me to use the Agilent 34972A with Dasylab 12. I have connected the device to max and installed the IVI drivers and everything seems to be connected ok (VIA LAN CABLE) However when i try to use the IviDmm+ module in Dasylab 12  i get the error.
    IVI API Function IviDmm_ConfigureMeasurement return with error -1074135023.
    Iam new to MAX and was wondering do you need to set up a channel list in max and if so how do i do this?
    Thanyou
    Brian

    Duplicate Post:
    http://forums.ni.com/t5/DASYLab/could-you-tell-me-​what-this-error-is-please-IVI-API-Function/m-p/175​...
    Nick C.
    Cardiff University

  • PCIe-653x with traditional DAQ

    Hello,
    we want to upgrade some of our existing system with a PCIe-6536. Is it possible to run this card with traditional NIDAQ?
    Does anybody have experience with PCIe-653x with traditional DAQ. Or is it only possible to run this card with DAQmx?
    Greetings
    Oliver
    Solved!
    Go to Solution.

    Hi Oliver,
    PCIe boards are generally not supported by the old traditional DAQ driver.
    Anyway you should consider updating your application to DAQmx, as the trad. DAQ support is pretty limited (see also official statement from NI below)
    "Caution  Traditional NI-DAQ
    (Legacy) is an older driver with outdated application programming
    interfaces
    (APIs) for developing data acquisition, instrumentation, and control
    applications for older National Instruments DAQ devices. You should use
    Traditional NI-DAQ (Legacy) only in certain circumstances. Refer to the
    NI-DAQ Readme for an overview of the two NI-DAQ APIs, the
    advantages of
    NI-DAQmx, and more information about when to use Traditional NI-DAQ
    (Legacy),
    including a complete list of supported devices, operating systems,
    application
    software versions, and language versions. You can install the latest
    version of
    NI-DAQmx software, available at ni.com/downloads. 
    Regards,
    Bernd

  • Problems with dasylab

    i need to calculate the output of a quarter bridge using strain gage,i can just read the output values directly from the bridge using a voltimeter but with dasylab i get a lot of values and i can see no changes when im bending the beam(the SG is sticked on it).the amplifier is configured with 5v input and a gain of 100,how can i configure dasylab to see the same results as with a voltimeter(0v when there is no bending and ?v when i aply a force)
    Thanks

    I thank you for your help,Im making my thesis in a company and we are using the full version of dasylab,so there is no problem with the software,but i´ve found the problem.it was a really stupid mistake.our measurement box it´s configured with 3 board card that use an other student for his thesis(every card with 4 channels) and now we´ve just instaled a new card also with 4 channels for my thesis prupose(measurement with Strain gage) the problem was in the numbre of channel that i used,i used always the channel number(0),and i must used the channel number(12),because there is 16 channels in total from(0,1,....15) so the first channel of my board card is the channel(12).
    So I made my pretest with a SG sticked in a beam(claculate the elongation when its bending) and the results were really closer to the theoritical calculation,i was really happy,but the real target of my thesis is to calculate the strain in the stabiliser of a car,and it´s with a biaxial SG applying a torsional force.
    the pretest was static but with the stabiliser we will have a dynamic test using cylinders to give the torsional force to the stabiliser,so then i have to take care about the frequency and a lots of others factors.
    So i hope that i can solve the problems that maybe occurs during my test next weeks,i thank you once again and if i have some other questions i will contact you.
    Best regards

  • Lock agp/pci clock with software

    hi,
    I have a MSI pro2-C (MS-6562 100 rev0.4) and can't lock the agp/pci clock with bios.
    Do you know a software which do that ?
    thx
    winxp sp2
    pentium4 1.7 willamette

    -> LINK to the MB specifications.
    MSI Pro2-C / MS-6562_i845
    With this bios (1.1), I can't lock the agp/pci clock to 66.66/33.33 and when the FSB is about 105, pci extensions are out.
    So, I would like to know if it's possible to lock agp/pci clock with the BIOS 1.2 (or maybe another bios), or if it's possible to do that with software (and if yes, which software)
    CPU is p4 willamette 1.7 (17*100) and I think it would be possible to reach a fsb around 120 (@2040 Mhz) if I can lock agp/pci clock.
    thanks for your help
    and sorry for my english, i'm french 

Maybe you are looking for

  • The DVD drive fails to read some disks

    Audio disks and program disks that read OK on my other Macs may fail to read on this one, yet this one recognizes most disks with no trouble. I'll buy a few new music disks and two will be fine while the 3rd isn't recognized. I put the unregognized o

  • Error in operation level result recording

    Hi, I need held; result recording of inspection type =03 (operation level Quality inspection) A product manufacture via three operations (10, 20, 30) All operation quality inspection active let operation no-10, all products reject and confirm as rewo

  • Map ID call in RH11

    I have been using RH7 and Map IDs.  I have upgraded to RH11, but I cannot figure out how to get my Map IDs to work.  In RH7 it was a simple URL call, .../roboapi.asp?Context=Map ID  What would the call be in RH11?

  • Difference between AS Java and Java Add-in

    Hi Guys Can anybody explain me the exact difference between AS Java and Java Add-in? How can I identify a SAP ABAP system is installed with Java Add-in or AS java? Regards Dharmendra

  • Moving transport to different systems and different mandants

    Hi all, I'm new to sap transport managment, so I hope this is not too obvious question. I've this kind of hypothetical situation. I have one develoopment system and 2 quality. On development system I have mandants 100, 200 and 300. On quality 1 I hav