No lo puedo instalar labview 2011 Control Design and Simulation

no e podido encontrar la verision para instalarlo agradezco si alguien me puede ayudar y guiar  en la instalacion 

Hola, [email protected]
Gracias por utilizar los foros de discusión, en el siguiente link puedes descargar el módulo LabVIEW Control Design and Simulation 2011.
www.ni.com/download/labview-control-design-and-simulation-module-2011/2554/en/
¡Saludos!
David P.
National Instruments
Ingeniería de Aplicaciones
www.ni.com/soporte
David P.
National Instruments
Applications Engineer
www.ni.com/soporte

Similar Messages

  • Control Design and Simulation and DAQ

    I'm learning Control Design and Simulations. I have some questions about it.
    1. For System Identification use, we can find the transfer function/model of the system by feeding data measurement from the system. But, how long data do we need to be sufficent for Identification System to estimate the model? Until the get saturated value (steady state)? or any other intervals? What if the system is unstable? How will Identification System Toolkit estimate that case?
    2. For connecting to hardware, we just connect the clock in the simulation loop to the hardware? And the simulation loop will simulate the blocks inside once it got the trigger/data from the DAQ? what about the step time and solver? Do they follow the timing from hardware? or they will run on their own supplied values/clock?if we use USB DAQ, we can't have any clock from it (as far as I know it's because USB connection is not that stable for clocking since it might be any jitters or delays.) So, how do we configure the timing parameter for USB DAQ?
    3. There is possibility to convert model in transfer function to state space, how do we know the states inside that conversion?
    Any helps would be great...
    Thanks in advance...

    Dear Chin ho,
    After going through your questions I found some documentation which will be useful for you. But I you still have more questions, you can reply me any time.
    1- About the data and amount of it I couldn't find any info but maybe you can use the new functions in LV version 2009 and find your answer.
    Estimating States of Nonlinear Stochastic State-Space Models with Extended Kalman Filters
    In previous versions of the LabVIEW Control Design and Simulation Module, you can use the Discrete Kalman Filter function and the Continuous Kalman Filter function to estimate the states of a linear discrete or linear continuous stochastic state-space model, respectively. In the LabVIEW 2009 Control Design and Simulation Module, you can use the Continuous Extended Kalman Filter function and the Discrete Extended Kalman Filter function to estimate the states of a nonlinear continuous or a nonlinear discrete stochastic state-space model, respectively.
    The Continuous Extended Kalman Filter function and the Discrete Extended Kalman Filter function estimate model states of a partially observable plant based on noisy measurements. First, use the SIM Discrete Nonlinear Plant Model template VI or the SIM Continuous Nonlinear Plant Model template VI, located in the labview\templates\Control and Simulation directory, to define the system model. Then use the the Discrete Nonlinear Noisy Plant function or the Continuous Nonlinear Noisy Plant function to simulate the discrete or continuous nonlinear model, respectively, with the addition of noise. Finally, use the Continuous Extended Kalman Filter function or the Discrete Extended Kalman Filter function to estimate the states of your model.
    The Continuous Extended Kalman Filter function and the Discrete Extended Kalman Filter function linearize the nonlinear system either by calculating a Jacobian matrix internally or by using an external Jacobian matrix that you define. Use the SIM Continuous Jacobians template VI or the SIM Discrete Jacobians template VI, located in the labview\templates\Control and Simulation directory, to define an external Jacobian matrix.
    Refer to the LabVIEW Control Design User Manual, accessible by navigating to the labview\manuals directory and opening CD_User_Manual.pdf, for more information about estimating the states of nonlinear stochastic state-space models with extended Kalman filters.
    2- I think that I found a pdf document about this part of your question which will be helpful. If you would like to give your email address, I can send it to you.
    3- About this part you can check the help function in LabVIEW when you open the "CD Convert Transfer function To State-space" function in your front panel.
    I pasted some info about the mathematic part below.
    The LabVIEW Control Design and Simulation Module provides tools to study the dynamics of systems described by linear time-invariant (LTI) continuous and discrete models. You can create deterministic state-space, transfer function, and zero-pole-gain models. You also can create stochastic state-space models and the second-order statistics noise models.  You can use these forms to describe both single-input single-output (SISO) and multiple-input multiple-output (MIMO) systems.
    Continuous transfer function and zero-pole-gain models use the s variable to define time, whereas discrete transfer function and zero-pole-gain models use the z variable to define time.  Continuous state-space models use the t variable to define time, whereas discrete state-space models use the k variable to define time. 
    Deterministic State-Space Model
    Continuous
    x(t) = Ax("t) + Bu(t)
    y(t) = Cx(t) + Du(t)
    Discrete
    x(k + 1) = Ax(k) + Bu(k)
    y(k) = Cx(k) + Du(k)
    Stochastic State-Space Model
    Continuous
    x(t) = Ax(t) + Bu(t) + Gw(t)
    y(t) = Cx(t) + Du(t) + Hw(t) + v(t)
    Discrete
    x(k + 1) = Ax(k) + Bu(k) + Gw(k)
    y(k) = Cx(k) + Du(k) + Hw(k) + v(k)
    Second-Order Statistics Noise Model
    Q = E{w . wT} – E{w} . ET{w}
    R = E{v . vT} – E{v} . ET{v}
    N = E{w . vT} – E{w} . ET{v}
    where
    t is continuous time.
    k is the model sampling time multiplied by the discrete time step, where the discrete time step equals 0, 1, 2, …
    x is the model state vector.
    u is the model input vector.
    y is the model output vector.
    w is the process noise vector.
    v is the measurement noise vector.
    A is an n × n state matrix of the given model.
    B is an n × m input matrix of the given model.
    C is an r × n output matrix of the given model.
    D is an r × m direct transmission matrix of the given model.
    n is the number of model states.
    m is the number of model inputs.
    r is the number of model outputs.
    G is a matrix relating w to the model states.
    H is a matrix relating w to the model outputs.
    Q is the auto-covariance matrix of w.
    R is the auto-covariance matrix of v.
    N is the cross-covariance matrix between w and v.
    E{} denotes the expected value or the mean of the enclosed term(s).

  • LabVIEW Control Design and Simulation Module version 2013

    I have had Labview downloaded for quite some time now. Downloaded control design and simulation module. Installed it. When i go to use it in the
    functions menu, only the window appears. Opening it shows an empty window. I have attached a screenshot of the issue. Could someone please explain to me what the problem is and how I can go about fixing it?
    Attachments:
    Labview screenshot.docx ‏998 KB

    As Altenback said, It is very possible it expired or it needs activation. To see for sure, go to your "NI License Manager" and expand the Modules. you should see:
    If not green then you have to fix the license.
    Barp - Control and Simulation Group - LabVIEW R&D - National Instruments

  • Control design and simulation module

    Hi,
    I am new to Labview and i am trying to work on Control System design. I have downloaded and installed the Evaluation Module of Control Design and Simulation Module. The problem I am facing witht this is its not showing any control fuctions in functions Palette. While installing it said its installing only control design and simulation assistant. Please, can anyone help with this.
    I am actually looking at this module to implement Sliding mode control for non linear systems. I would like to know if there are any examples to implement this??
    Thank You.

    Hello
    The problem is the following. The version of LabVIEW that you are using does not match the version of the evaluation version of LabVIEW Control Design and Simulation Module (CD&SIM). If that happens, the installer will not select the support files for your LabVIEW. If you download LabVIEW 2011, then you must install CD&SIM 2011.
    Now, the module in the current version does not have an example with sliding mode control. But using this module, you can easily implement the algorithms and simulation its result using the Control and Simulation Loop.
    Hope this helps.
    Barp - Control and Simulation Group - LabVIEW R&D - National Instruments

  • Control, design and simulation

    Hello everybody,
    I am trying to run a simulation in Control Design and Simulation module. My simulation consists of various simulation systems. The subsystems are working as desired when run as separate units, but when I run the complete system, the subsystems fail to produce the output values. 
    I have not used any local variables or any discrete function vi inside a subsystem.
    Where am I wrong ? Any help would be much appreciated.

    I mean the indicators connected to various subsystems are inactive and don't produce any output values. I tried to find the error using the Error Cluster, but it didn't show any error. I am using LabVIEW 2011. I have attached the complete system including the subsystems. The individual systems are working fine. I changed the solver too, but the problem persisted. Please try to identify the error.
    Barp wrote:
    When you say: Fail to produce a output, what do you mean?
    On the right side of the Control and Simulation loop you have the 'Error Out' cluster. Create a control from it and see if you have an error. Also, which version of LabVIEW are you using?
    If this is not producing an error, then try to change the solver you are using. It would help if you could post your code (or at least pictures) of it.
    Attachments:
    Wind Turbine Integrated.7z ‏2240 KB

  • Control design and simulation palette

    Hi all
    I've recently installed LV 8.2 professional edition on my PC.
    Watching the function palette i've seen the sub-palette 'Control design and simulation' empty... Is it normal? Do i need some toolkit to see something in it?
    King regards
    I love the smell of napalm in the morning

    alij wrote:
    its because the main labview is install in c:\program files , but when you install the module it will install in programfiles(x86) ,that because the **bleep**ing bug in the installation and programmers , plz fixx this , i think you have to copy paste files into the main NI labview which is in program files not program files (x86)...
    If LabVIEW is installed in "c:\program files", it means that you installed LabVIEW 64bit. You should install LabVIEW 32bit, which will go to "c:\program files(x86)" and will be compatible with your toolkit.
    There is nothing wrong with the installer. You simply picked the wrong product.
    Do NOT copy files between the two mentioned folders. One is for 32bit applications and one is for 64bit applications (assuming you have a 64bit OS).
    The toolkit is not compatible with 64bit LabVIEW (Details).
    LabVIEW Champion . Do more with less code and in less time .

  • Control Design and Simulation palette doesn't appear

    I'm using LabVIEW 2009 in Professional License. I've installed Control Design and Simulation Module with its all other required Toolkits. The problem is that Control Design and Simulation palette  doesn't appear in the Functions Palette in any VI. Please help me with that.
    Adeel Amin
    NED University of Engineering & Technology
    Solved!
    Go to Solution.

    If you run NI License Manager, Expand LabVIEW2009>Modules>Control Design and Simulation.Can you verify that you have that directory and what is the color of the cube right next to it?
    Andy Chang
    National Instruments
    LabVIEW Control Design and Simulation

  • Control Design and Simulation Tutorial

    Hi
    I'm starting off with a coursework which requires use of the Control Design and Simulation functions. Before I ask any silly questions i'd like to see the hand on tutorial, it's referenced in this white paper.
    http://www.ni.com/white-paper/5855/en/
    However the ftp link to the tutorial doesn't work, does anyone else have an alternative link, or could supply the tutorial directly.
    I appreciate any assistance.
    Kind Regards
    Danny
    Solved!
    Go to Solution.

    Hmm, thanks. It must've been the proxy server in the office. Disabled and it downloaded it via the wifi.
    Thanks

  • Control design and simulation toolkit

    Hello everyone,
    Does anybody know if indexing is possible in a Control and Simulation loop in Labview? I need to save in an array all the simulation data.
    Thanks,
    Ussr123.
    Solved!
    Go to Solution.

    Solved: the necessary icon is called: Collector.

  • How to reset indicators in a control design and simulation loop before each run?

    Hi,
    I am new to Labview. I have tried using property node to reset indicators before each run. But since it is in a simulation loop, it gets resetted many times. I am primarily interested in resetting only before each run. 
    Any hint will be of great help.
    Thank you!
    Regards,
    Divya

    Hi Divya, 
    This KnowledgeBase article describes 2 methods for resetting your Front Panel programmatically:
    http://digital.ni.com/public.nsf/allkb/08E7DDAE66A7D02C86256DDA00630E75
    However if you have tried these methods, and are still not getting the behaviour you want, it would be easier to help if you could post your code (or even a screen shot of the section of code where you're trying to reset your values)

  • Labview 2011 NI Report and error 7

    I know this topic has been cover in this forum many times, but I just can’t get it working.
    Recently, we have updated our labview from 8.2 (Window XP) to 2011 sp1 (Window 7), and of course, NI report stops working.
    In our software, we have a project that eventually gets compile into a DLL (Not AN .EXE, THIS IS NOT AN EXECUTABLE). In this DLL, we modify an excel spread sheet. As a result, we need the NI report tool kit.
    Now I know that you would have to manually include the two folders (NIReport and LVclass)in your project in order for this to work in labview 2011, which I did by following the link below.
    http://digital.ni.com/public.nsf/allkb/8A0E6274D9BD7B1986256F62006AD402?OpenDocument
    I made sure that the two folders were “Always Included”, and not using the labview 8.x file layout. After the compiling has been complete, one DLL was created (with 4 other files, which is good because I only want one DLL). I assumed that the NI report tool kit is included in the build since I selected “Always included”.
    After that I ran my main top level vi. The main top level vi tried to access the DLL, and I got error 7,
    Get LV Class Default Value.vi<APPEND>
    <b>Complete call chain:</b>
         Get LV Class Default Value.vi
         Test.vi
    <b>LabVIEW attempted to load the class at this path:</b>
    C:\BUILD PATH\DLL NAME.dll\1abvi3w\vi.lib\Utility\NIReport.llb\Excel\NI_Excel.lvclass
    Now I assume this might be caused by two reasons. The path is incorrect or the tool kit wasn’t included.
    I have been working on and off with this problem for weeks and still can’t get it working. I am guessing the path is incorrect, but I have manually changed the path to something different but got no luck. Any suggestions?
    Solved!
    Go to Solution.

    Hi,
    Thanks for the reply. 
    The reason I didn't select "use Labview 8.x file layout" is because it will also create 10 extra support folders (I think this is due to name conflicts in the DLL directory) after compiling the project. This is not an acceptable solution for my customer since no one would want a DLL that comes with so many extra files.
    And yes, I am aware of the file layout after Labview 2009. However, the path to NI_Excel.lvclass (C:\BUILD PATH\DLL NAME.dll\1abvi3w\vi.lib\Utility\NIReport.llb\Excel\NI_Excel.lvclass) was provided by “Excel class path.vi” (vi.lib\Utility\NIReport.llb\Excel class path.vi). In “excel class path.vi” it checks to see if the application is using the 8.x layout or not.
    I switched to “use Labview 8.x file layout” just for testing reasons but it still doesn’t work. The file path for NI_Excel.lvclass is now C:\BUILD PATH\DLL NAME.dll\Excel\NI_Excel.lvclass (provided by “Excel class path.vi”). I also hard coded the path to C:\BUILD PATH\DLL NAME.dll\NI_Excel.lvclass and that doesn’t work too.
    I have created a simple project to demonstrate my problem. Copy the attached folder to your desktop and you will see a folder named “Excel”. Open the “excel Test” project and build the DLL, check the build path and make sure it’s building to “Desktop\excel\Exceltest”. After that go to the DLL TEST folder (\Desktop\excel\DLL TEST) and run DLL test.vi. Make sure the path to the DLL (on the block diagram) is correct and run the vi. You should see the error I am talking about.
    Thanks,
    Attachments:
    excel.zip ‏19 KB

  • Grid control design and agent deployment

    To give you a brief overview of the setup here, it is currently an agent per instance instead of an agent per host. This was done to allow an agent to be moved along with an instance to another host in a cluster (we are using IBM AIX LPAR, and Sun Clustering) thereby allowing a seamless transition between hosts and history retention for the instance. We would like to change this to an agent per host, however, we need to keep the historical information of the instance should it change hosts. So my questions are:
    1. Is it possible using some sort of script or process to have an instance/target move between hosts and retain its previous historical information?
    2. Is it possible to have a single, summarized availability report for all instances? The report per instance works, however, doing a single summary report for all instances does not display the correct information (it only shows PIT, i.e. the current state of the instances not historical over x period of time).
    Any help is appreciated.
    Thanks.

    Let me provide some details as to the environment as to the deployment which I am doing in a HA environment:
    - There is a physical 'myhost1' with virtual hosts names oradev1, oratst1. Note I am not referring to virtual machines, just virtual host names, or virtual IP.
    - Each VIP hosts a listener and database instance. For example, oradev1 -> lsnr-oradev1 + orad1, and oratst1 -> lsnr-oratst1 + orat1
    In this design each database and listener can be moved to another physical host separate from the other, say the entire oradev1 stack moves to 'myhost2'.
    How would the agents be deployed in such a design? I think an agent per physical host, with the VIP used to monitor the virtual stacks, such has as each virtual host containing the listener and database instance. This way when a virtual stack moves we can just switch the agent monitoring that stack to the new host and retain the history of the targets.
    Is my thinking correct? Is there a better way to retain the history when moving the virtual stacks perhaps doing an agent per instance instead of physical target?
    I hope this provides more details. Thanks.

  • Can't install Control and Simulation Module in LABVIEW2009

    HI all,
    I m using LABVIEW2009 x64 and wanted to update control module in it.
    when ever I try to install the Control DEsign and Simulation module, the setup won't proceed.
    IT shows the following error message : 
    NI LabVIEW 2009 Control Design and Simulation Module
    The Control Design and Simulation Module requires LabVIEW 2009 Full or Professional Development System to be installed.
    however, I have already installed and reinstalled once as well. Please help me.

    Hi Rishabh,
    Unfortunately, we do not have a version of Control Design and Simulation for x64. You can try to install the 32-bit version of LabVIEW instead on a 64-bit OS. This should allow you to install CD&SIM.
    Please let me know if can help any further.
    Barp - Control and Simulation Group - LabVIEW R&D - National Instruments

  • Transfer functions in the 64 bit version of Labview 2011

    Hallo all,
    I am running a 64 bit version of Labview 2011 and I would like to know is it possible to use transfer functions in this version?
    I found only a 32 bit version of Control Design and Simulation Toolkit, is there something else I could use for this?
    Thank you,
    Vladimir

    Hello,
    Thanks for your posting in this forum. Unfortunately you cannot use this function in the LabVIEW x64. You can check the link below
    http://forums.ni.com/t5/LabVIEW/LabVIEW-64-bit-support-for-modules-and-toolkits/td-p/996044/page/2
    But you can try the option below, but I cannot say that it would work.
    You can install the LabVIEW x32 and then Control Design & Simulation Module .
    Then copy the library of this module somewhere else.
    Then you can install the LabVIEW x64 and copy that library in its folder.
    Maybe it works.
    Regards,
    Hossein

  • Control design

    Hola ahora trabajo con labview 2013 pero no encuentro como instalar control design alguien sabe como hacer esto!
    Solved!
    Go to Solution.

    Hola Laurentino...
    En la resouesta anterior te envían la liga de descarga para la versión 2014, que por cierto, te recomiendo que descargues en lugar de la 2013, en fin; si deseas seguir en la versión anterior. 
    La versión 2013 la puedes encontrar en la liga:
    Control Design and Simulation Module
    http://www.ni.com/download/labview-control-design-and-simulation-module-2013/4207/en/http://www.ni.c...
    Exito

Maybe you are looking for

  • Photoshop Elements 7 Editor crashes upon opening any image

    I have been trying for 2 days to get my Photoshop to work. I've used PSE7 for years, no issues. Suddenly yesterday, every time I try to open an image in the full editor, I get the "Photoshop has stopped working... check online for a solution or close

  • Not able to view users in F4 with Last Name, First name with tcode-PA20

    When we go to PA20 tcode and input personel id the details are shown for person. But When I select F4 at the Personel Number and enter  Last Name and First Name - It shows No Values selected Which authorizations are required for populating F4 data in

  • Transferring music from one account to another

    I wanted to know if there is any way I can transfer music from one account to another account, my music library has over 1000 songs and i do not want to download them again, is there a way? THANKS!

  • How do I get rid of the start-up window?

    I've just installed QuickTime, but when it started I was presented with a window full of advertising. I cannot find anything on the menu allowing me to disable that gross display. How can I get rid of this start-up headache? Thank you for any helpful

  • Wrong status for PO in SRM Portal

    Expert's, I'm trying to update a status in SRM 5 portal for a  purchase order. The main problem was that the status was " error in process" because the PO was not tranfered to the backend system. Manually, using BBP_PD_PO_TRANSFER_EXEC the PO was tra