No notifications only sound and vibration

since 2-3 days ago my phone started to vibrate and also a notification sound can be heard at random times. i have no notification in the notification drawer. i found in latest app notifications something called oma client....i forced stopped it, can't uninstall it and the notification is still there. any ideas?

https://en.wikipedia.org/wiki/OMA_Client_Provisioning
This OMA seems to be kind of a service for pushing updates or something like that OTA. Well, have you tried the repair?

Similar Messages

  • Sound and Vibration pallet is only for ...

    Hi,
             I installed Labview on my system and I saw Sound and vibration Pallet. Now, I am working with 4610 accelerometer through USB 6008 and analyzing the Voltage levels in labview. I have a doubt that the sound and vibration pallet is only for when using NI sound and vibration kit or can I use those options in this project.

    in a loop - capture a waveform (4096 points for example) from your accelerometer - analyze it, and then output a serial command with the adjustment based on your analysis. 
    repeat the loop until some measurement is met - the serial device is stable, for example. 
    Preston
    Preston Johnson
    Principal Sales Engineer
    Condition Monitoring Systems
    Vibration Analyst III - www.vibinst.org, www.mobiusinstitute.com
    National Instruments
    [email protected]
    www.ni.com/mcm
    www.ni.com/soundandvibration
    www.ni.com/biganalogdata
    512-683-5444

  • Sound and Vibration Toolkit with NI-SCOPE AND NI-FGEN

    Hi,
    I would like to use the Sound and Vibration Toolkit with the NI-FGEN and NI-SCOPE,specifically the stepped sine analysis. The stepped sine VI's are compatible with only DAQmx and not NI-SCOPE and NI-FGEN,right?
    Any way around this?

    Hi there,
    Firstly I assume you mean Swept sine and not stepped!?
    This is the closest thing I could find:
    http://zone.ni.com/devzone/cda/epd/p/id/3347
    I had a look for you and there is nothing that works with a swept sine in FGEN or SCOPE natively that we supply.  However I do believe that a lot of the functionality could be programmed in FGEN and SCOPE vi's.
    You would however need to make copies of all the Swept Sine VI's and replace all DAQmx calls and property nodes with the appropriate SCOPE/FGEN vi's.
    Not a short answer I'm afraid and I can't guarantee that all the functionality is going to be there.
    Sorry its not a better answer.
    AdamB
    Applications Engineering Team Leader | National Instruments | UK & Ireland

  • Sound and Vibration toolkit for vibration analysis

    Hi guys! I am new to Labview. I am trying to use Sound and Vibration toolkit to analyse the accelerometer signal mounted on a motor through myRio. The analysis are spectral map, order tracking, power spectrum, order spectrum etc. But nothing can be seen from the output graph. The only result I get is from vibration level.
    Attached is a screen shot of my vi and actual vi file. Am I doing it correctly? I really need your help guys....
    Thanks.
    Attachments:
    Vib.vi ‏384 KB

    SK,
    You have serious problems in your File.VI.  Why are your writing to your file and then reading it right back?  Worse, there is no guarantee that the File write will actually occur before the File Read.  You have a race condition set up there between those two Spreadsheet File VI's.
    If you want to maintain a history of whatever has already been written to the file, you should be building it into an array and storing in a shift register.  Even if your File.vi would by chance work the way you want it to, storing data in the file system is much slower than maintaining your data in memory.
    As for your while loop, it is going to run as fast as it can with respect to all the functions occurring inside of it.  Is it possible you are getting 14 iterations of that while loop for each frequency step that is occurring?
    Message Edited by Ravens Fan on 07-25-2009 01:35 AM

  • How to reset Sound and Vibration Spectral map

    Hi,
    I want to create a Campbell diagram for a rotating machine, in live (while the machine is rotating).
    This diagram is basically a graph of the spectral content a a signal (Hz), versus the rotation speed (RPM).
    I've found an express VI that seems to do what i want to do (Spectral Map, in the Sound and Vibration toolkit). The output of this VI is buffered so that it can run in live (The buffer vi is also a vi that comes from the Sound and Vibration toolkit).
    The block diagram of my complete process is attached to this message, sorry it's a bit messy.
    On the first run, this VI works as expected: as the machine is running up, the graph is filling up. Now if I want to make a second run-up, i need to first reset the VI. However once the vi has been reset, it won't ouput anydata!
    I've tried different combination:
    - Reset  "Waterfall and Campbell.vi" and the buffer
    - Reset only the buffer
    - Reset only the "Waterfall and Campbell.vi"
    None of them work, the colormap stays black. 
    So does anyone know how to use this express vi? I could find an exemple that works with live data and buffering.
    Thanks,
    Regards,
    peper
    Attachments:
    Reset waterfall.png ‏74 KB

    Hi,
    Attached to this post, you'll find a piece of code that replicates the problem I have in my main application.
    If you run the vi with an initial small frequency (the frequency dial up simulates the rotation speed) and then increase that speed, you'll notice that the spectral map gets filled as expected.
    The problem arises when I try to reset the spectral map (=do a new run-up):
    - I set the frequency to a minimum
    - I hit the reset button (the spectral map is emptied as expected)
    - I slowly increase the frequency ===> the spectral map does NOT get filled up anymore. Or it gets filled up like 30 seconds after the run up or gets partially filled up.... in summary there is something wrong with the map each time I try to reset the septral map vi.
    Let me know if you need more information.
    Best regards,
    peper2001
    Attachments:
    Campbell.zip ‏101 KB

  • Where is the asper measurement in Sound and Vibration assistant

    I did a test drive of the Sound and Vibration Suite, liked what it could do, but could only afford the Toolkiit. Now I can't find the Asper (Roughness) measurement in the Toolkit. Is it there? I found the Loudness, Sharpness, etc.

    Hi elrathia,
    I think you are looking for the Sound and Vibration » Sound Quality » SV Aures Roughness function.  It should be included with the toolkit.
    Kyle B  |  Product Support Engineer  |  ni.com/support

  • Sound and Vibrate does not work at same time

    Hi Support,
    I have recently purchased BlackBerry Z3.
    It does not support Sound & Vibrate at same time.
    In Normal mode, I have enabled Sound and Vibrate but it does only give sound for incoming calls/messages.
    (does not vibrate)
    In Vibrate Mode, it does only vibrate.
    This is the first time I am using Blackberry and I am annoyed with the basic feature not working.
    Please respond.
    Regards,
    Sunil.
    Solved!
    Go to Solution.

    I'm glad things are back to normal for you.
    Cheers.  
    - If my response has helped you, please click "Options" beside my post and mark it as solved. Clicking the "thumbs up" icon near the bottom of my response would also be appreciated.

  • SOS(The Question of SVXMPL_Settled Dynamic Range (DAQmx) example in Sound and Vibration Toolkit)

    The SVXMPL_Settled Dynamic Range (DAQmx) example in Sound and Vibration Toolkit only run one time.
    How do it ? I want to run again and again.
    Sorry, my English very poor.
    Windows XP P
    LabVIEW 7.1 P
    Sound and Vibration Toolkit 3.1
    帖子被jwdz在10-22-2005 11:00 PM时编辑过了
    " 一天到晚游泳的鱼"
    [email protected]
    我的个人网站:LabVIEW——北方客栈 http://www.labview365.com
    欢迎加入《LabVIEW编程思想》组——http://decibel.ni.com/content/groups/thinking-in-labview

    Hi:
    I have simulated PXI-4461 in MAX,but the SVXMPL_Settled Dynamic Range (DAQmx) example in Sound and Vibration Toolkit  can not right run.
    Windows XP P
    LabVIEW 7.1 P
    DAQmx  7.5
    Sound and Vibration Toolkit 3.1
    " 一天到晚游泳的鱼"
    [email protected]
    我的个人网站:LabVIEW——北方客栈 http://www.labview365.com
    欢迎加入《LabVIEW编程思想》组——http://decibel.ni.com/content/groups/thinking-in-labview

  • My Iphone 5 will not notify me when I have a text message. There is not banner notification, not sound, or vibration. I have to click on the message icon to even see if I have a text message.

    My Iphone 5 will not notify me when I have a text message. There is not banner notification, not sound, or vibration. I have to click on the message icon to even see if I have a text message.

    Settings app > Notification Center > Messages (you will need to check both the INCLUDE and DO NOT INCLUDE sections). Set the alerts you wish to see.

  • Sound and vibration

    We are trying to capture friction noise / sound of the Gear Mesh during rotation is it possible get the output result into Micro-radians. We appreciate your kind help.
    Thanks
    BLAK

    Hi JHess,
    the Sound and Vibration Assistant is installed with NI Sound and Vibration Measurement Suite and NI Sound and Vibration Toolkit.
    You can download only the most recent version from the site that is 7.0.
    You can download this version at this link and use it in evaluation 30 days.
    Best regards,
    Serena M.

  • 5s phone makes a loud sound and vibration when talking on the phone. Any advice on this?

    Need help with this.. iPhone 5s makes a loud sound and vibration while talking. So bad you have to hang up and call back. I have been to Apple and they have replaced the phone 3 times and still having the same problems

    My 5s did exactly as you describe only on the left side of the display.
    I exchanged mine as this is unacceptable and does not bode well for long term durability (on the creaky units).
    You have 30 days I think for defective units. Better make an appointment with support and get it noted for the record or replaced.

  • How can i measure the speed of the fan in sound and vibration signal simulator box

    how can i measure the speed of the fan in sound and vibration signal simulator box
    provided the values  tach out:2 pulses/revolution and  maximum speed = 6000rpm

    Hi. I tried your suggestion and I could not get it to work well. In
    fact it worked better without the running average (which suprised me).
    I also played with the number of data points but still could not get it
    to work well.
    Do you have any other suggestions on how I could sort this problem out?
    I
    have attached a screen shot of the signal. To recap, I'm trying to
    measure the'y' position of the flat regions of the signal. The signal
    does not have a constant level, so this 'y' position varies with time
    in a non-unform manner.
    I am currently differentiating
    the signal and selecting the y position when the differential is equal
    to zero (within a tolerance band).
    In the screenshot, the
    signal has been zeroed using the method I have described above.
    However, it occasionally has glitches which may be caused when the code
    picks up a zero gradient at a peak or valley in the signal.
    I therefore need some kind of algorithm that only measures the position of the flat regions.
    Many thanks
     John
    Attachments:
    screenshot.gif ‏121 KB

  • Average multiple signals together in sound and vibration assistant

    Hello,
    I would like to average octave analysis data from multiple microphone channels together to obtain a single set of octave analysis data to view within Sound and Vibration Assistant (a surface average from the microphones).  I have created an octave averaging vi in LabVIEW to run in SVA, but I get the error that there are no signals in my SVA project to input into my vi.  I have based the input of my vi on code generated from SVA which outputed multichannel octave analysis data, so I don't quite understand why the output from an octave analysis in SVA doesn't match up to the input of my vi.
    I also would like to do this for multichannel power spectrum data, and I have tried creating my own vi for this as well with no success.
    I am using LabVIEW 2011 32-bit along with Sound and Vibration Assistant 2011.
    Any assistance with finding a solution to this problem would be greatly appreciated.
    Thank You,
    Eric Morgan
    Attachments:
    Octave Average.vi ‏13 KB
    Power Spectra Average.vi ‏13 KB

    Hello Jake,
    Thank you for responding to my post.  After recording the raw sound pressure data from my microphones, I placed an Octave Analysis step and a Power Spectrum analysis step in the playback section of SVA, and the outputs of these steps should have served as inputs to the VIs I created (I assume you only looked at the power spectrum averaging VI, as the octave averaging VI accepts a 1D array of clusters of center frequencies and band powers).  I did find that my averaging VIs did not have the correct size of empty array going into the second For loop, so I have corrected this in the attached VI (for averaging the FFT).
    Also, I was able to get my corrected VI for averaging the FFT to work after getting past a little quirk in SVA.  After browsing to my VI in setting up the "Run LabVIEW VI" step, I had to click the "Refresh VI" button before it would let me select a power spectrum as its input.
    I also think I figured out why the octave averaging VI doesn't work.  I think it has something to do with the fact that the output of an Octave Analysis step in SVA can not be used as an input to any other steps within SVA, which makes sense most of the time since once you have performed an octave analysis, there is really no other processing of this data that would ever need done...except for my case of averaging the 10 channels together to obtain the surface average SPL (kind of important when testing according to ISO3744).  If this is the case, I would consider this a bug in SVA, as any output from any step in SVA that can be displayed should be able to be used as an input to a "Run LabVIEW VI" step.
    I agree with you that in the end, it would be easier to do everything in just LabVIEW if I were just collecting data for post-processing at a later date, but when investigating noise issues and collecting mounds of data in the process, SignalExpress makes it a little easier to sift through that data as it is collected/logged while still in our sound lab, which may give us some ideas of different ways to test at that moment and possibly find the cause of our noise issues.
    Thanks again for responding to my post,
    Eric Morgan
    Attachments:
    AverageFFT.vi ‏19 KB

  • Frequency response - sound and vibration

    Hi,
    I need to find the frequency response of the DUT. I am using the NI example from sound and vibration toolkit to do
    so (LabVIEW 8.5\examples\Sound and Vibration\Getting Started\SVXMPL_Getting Started with Swept Sine (DAQmx).vi) now my problem is
    to tabulate the phase difference between the stimulus and response when i do it i get constant values. Even though i dont give any response 
    signal to the channel i get the wave same as stimulus, is it suppose to be like that !!!!!!!!!! I will attach my vi so that it gives the idea where 
    i am measuring the phase difference pls check it and help me with this.....thank you in advance.
    Attachments:
    DAQ Freq resp (req)_trial.vi ‏121 KB

    What is the DAQ card you are using for executing this Frequency Response?
    This DAQ error is related to the output frequency of your signal higher than the possible output rate of the card. Basically, you are trying to update at a rate higher than the capability of the card.
    For doing Frequency response, generally you need to have a NI DSA card (446x/447x/449x) with one Analog output and two analog inputs (minimum). Generate the swept sine signal from the Analog output channel, give this signal as input to your DUT and also to one of the Analog input channel. This input to your Analog input channel will act as your Reference signal. Then the response signal from your DUT, connect it to another Analog input channel. You would get a very good response results.
    The reason why you need to have a DSA board is that, for doing Frequency response, we need to acquire both high frequency and low frequency components without much loss. This is possible only if your DAQ board has a higher dB value (in the range of >110dB) which is present only in DSA boards.
    I have completed a Frequency Response Analysis just a week back with the same example programs. So there wont be any problem with that vi.
    Regards,
    Sundar Ganesh

  • Problem in Sound and Vibration toolkit Installation

    I have Sound and Vibration 3.1 installed in my machine and did upgrade (without unistall SV 3.1) to SV 4. VIs doing in other machine with SV 4 don't run in my machine. I try uninstall version 3.1 and stay only version 4, don't solve problem. The SV version 4 don't appear in function windows, but is installed in windows XP. Sound and Vibration section in the function windows only appear if i install version 3.
    How do upgrade of version 3.1 to version 4 and do the version 4 section appear in the window function?
    Leonardo de S. Cavadas
    Maintenance Engineer and Inspection - Bureau Veritas do Brasil
    Engineer Metallurgist with emphasis in Advanced Materials
    Technologist in Computer Science

    Solution for WinXP:
    1 - Enter in Configuration - Control Panel - Add/Remove Program;
    2 - Select National Instruments Software, click in Change;
    3 - In the new windows that opened, remove the Sound and Vibration toolkit 3.1 version and 4.0 version;
    4 - Restart Computer
    5 - Reinstall Sound and Vibration Toolkit 4 version.
    It's Work.
    Leonardo de S. Cavadas
    Maintenance Engineer and Inspection - Bureau Veritas do Brasil
    Engineer Metallurgist with emphasis in Advanced Materials
    Technologist in Computer Science

Maybe you are looking for