Notification origin
Hi,
When I close the notification, I get a popup to choose if its internal or external origin. I need to get more detail as to who is reponsible for the defect. For eg if its external then it could be the distributor, the manufacturer, the transport agency and if its internal it could be someone at receiving, someone in the warehouse. How do I record that ? Ideally I would like to assign the actual vendor, manufacturer, transport agency's ID or the internal person's ID who caused the actual defect after the notification is complete. How is the best way to do this so that I could run reports on that and see who is giving me maximum number of defects ?
Thanks
Check if you can use defect location code groups for this. If you refer to QM15 report following texts and codes are visible.
Code group of Defect Location
Code Group description of Defect Location
Code of Defect Location
Code description of Defect Location
Above set will be common (for logic) for catalogs of defects, causes, tasks, activities at item level and coding at header level.
What I can suggest is to explore whether all these have been properly utilized or not and try to set the logic of codes so that the individual code or code group will make some sense for reporting.
I doubt at the last instance of notification closure it will be possible or not but I can give 1 example by which this can be mapped. Create 2 code groups- One for Internal Origin and another for External Origin under defect location catalog. The agencies responsible for externals factors would be the codes of External Origin code group. Same way for internal.
Else you need to go with custome screen mapping and new Z table creations to store the information. When you click on internal or external radio button at the time of notification closure it will take you to different screen say vendor code screen from where you can choose required entry. Earlier option is more advisable, I would say!
Anand
Similar Messages
-
How to create a number ranges in QM notification?
Hi Exprets
How to create a number ranges in QM notification?
Please help me...
RamDeat Thyagarajan,
Notification type 01
Notification cat 05
Parameters
Notification origin General Notification
Catalog profile SAPISR
Early no.allocation 06 Number range
My Notification type 01, I am assined 06 number range. 06 number range have limit 1-100000.
I have used upto 100000. Now how I can extend my number limit.
Thanks for support...
Ram -
Completing quality notifications in bulk
Hi Guys
I need to change the system status of quality notifications (+/-500 000 records) to:
NOCO and
DLFL
We’re using SAP ECC6 EHP6. Please guide me to a standard SAP tcode/program that can be used for bulk/mass system status changes (QM10 will require manual actions and is therefore not suitable).
Notification origin = Q3
Notification category = 02
Best regards
WHello,
Yes same i was told you that in PM/CS such facility is available bcoz notification is linked with costing object like order and those needs to closed before month end for settlement. But in QM there is no such criticality and that's why SAP not provides mass closure.
Yes u cane use LSMW, eCatt and BDC like functionality for this in QM.
Regards -
LMS 4.2 - Two notifications for one alarm.
Currently when a device, say a router goes offline we receive two Active 'Unresponsive' alarms for the router and then when it comes back online we receive two Cleared 'Unresponsive' alarms. All have their own unique Event ID. (shown below)
I was wondering if anyone could help me to config LMS to send only one Active 'Unresponsive' notification when a device is offline and then one Cleared 'Unresponsive' when the device is back online.
Here's an example of the Active 'Unresponsive' alarms I receive when I power the router off:
Notification 1
EVENT ID = 0002BI5
TIME = Thu 29-Nov-2012 15:26:32 EST
STATUS = Active
SEVERITY = Critical
MANAGED OBJECT = router.domain
MANAGED OBJECT TYPE = Routers
EVENT DESCRIPTION = Unresponsive::Component=172.16.1.254 [router.domain];ComponentClass=IP;ComponentEventCode=1098;InterfaceType=ETHERNETCSMACD;InterfaceMode=NORMAL;InterfaceAdminStatus=UP;Address=172.16.1.254;IPStatus=TIMEDOUT;InterfaceOperStatus=UP;Ne
CUSTOMER IDENTIFICATION = COMMS TEAM
CUSTOMER REVISION = 1
NOTIFICATION ORIGINATOR = Fault Management Module
Notification 2
EVENT ID = 0002BI6
TIME = Thu 29-Nov-2012 15:26:57 EST
STATUS = Active
SEVERITY = Critical
MANAGED OBJECT = router.domain
MANAGED OBJECT TYPE = Routers
EVENT DESCRIPTION = Unresponsive::Component=router.domain;ComponentClass=Router;ComponentEventCode=1101;SystemObjectID=.1.3.6.1.4.1.9.1.569;Description=Cisco IOS Software, C870 Software (C870-ADVIPSERVICESK9-M), Version 12.4(15)T13, RELEASE SOFTWARE (
CUSTOMER IDENTIFICATION = COMMS TEAM
CUSTOMER REVISION = 1
NOTIFICATION ORIGINATOR = Fault Management Module
Any suggestions?Am I alone with this issue of receiving two notifications for one Unreachable event?
-
How is table TQ80 (Notification Types) maintained?
Hello experts!
For SAP Business Intelligence we have a standard interface (extractor) which extracts quality notification data. But only data from tables QMEL, QMFE, ... is extracted which has the origin of notification Q1, Q2, Q3.
This is selected over field HERKZ in table TQ80.
Please could you tell me what could be the business reason for this?
Can someone tell me how to maintain this table? Maybe over customizing?
Thanks for help!
Best regards,
Peterhi
Notification origin is used for screen sequence and differentiate the notification in respective moduel ,in case of QM it is qualtiy notification ,where as in PM it is maintenance notification which is further classified as malfuntion ,maintenance report etc.
it is predefined by SAP ,if you are creating new notification type you have to assign any one of the origin and create
regards
thyagarajan -
Hi All,
i would like to know how could i create a new combination of notification category with notification origin, to use 03 - Service Notification and Q1 Customer complaint and enable the "Defect Class" field.
Thanks in advance,
Gustavo Carvalheirahi
Notification category are not configurable, those are defined in the system & u can select the appropriate
We can define only Notification types.
generally you get these data in Q1 notif type.
if you want new one with all detailes mentioned by you then you need to do the IMG settings.
Plant Maintenance and Customer Service->Maintenance and Service Processing->Overview of Notification Type.
here you need to create a new notif type and then add the
screen
1.Screen Areas in Notification Header
Screen type hdr H500 Header quality notification
ScrnType Object O500 Object for customer complaint / batch
2.Screen Structure for Extended View
3.Screen Structure for Simplified View
etc...
and when you go to create the notification type from Define Notification Types, there based notification origin the system selects the catagory
-ashok
Edited by: ASHOK on Oct 22, 2008 6:06 PM -
Create SAP Notification?
Is there any scenario to create a notification with out eqipment and functional location?
Hi
You want to create a Notification for Equipment or functional location which are Not in use or Out of calibration.This is possible through Maintainca type of Notification.
SPRO->Maintainace & S.P>mainatainace & service processing->mainatainace & service Notification->Notification Creation ->Notification type>Define Notification.
Specify Notification origine-->malfunction report
In addition that in Equipment master or functional location master you can define a status which is will specfify :Out of calibration or Not in Use so that ,this equipmnet will not be scheduled for calibraion /maintainance. -
Seeburger AS2 MDN: Reading AS2 Header DATE field
Hello,
in my AS2 scenario (using Seeburger Adapter) I forward MDN messages to PI. Now I have the requirement to read the "DATE" field of the MDN AS2 Header an map it to a target field.
In the XML message monitoring there are two payload messages:
AckReport (application/xml) and
RAWMIMEMDN (application/octet-stream)
In the message RAWMIMEMDN I see the header data and also the DATE field, now the question is, can I use the RAWMIMEMDN somehow to extract the DATE field?
Thank you for your input.Looks like this: (However I am not sure how to use it in mapping as there are two PAYLOADS entries in SXMB, I have not seen this in any other scenario before, I guess I only have access to the XML part):
AS2-VERSION: 1.2
CONTENT-TYPE: multipart/report; report-type=disposition-notification; boundary="----=_Part_372_22591582.1258028532189"
AS2-TO: xxxxxx
FROM: xxxxxx
CONTENT-LENGTH: 798
AS2-FROM: xxxxx
MIME-VERSION: 1.0
SERVER: xxxxxx
MESSAGE-ID: <xxxxxx>
DATE: Thu, 12 Nov 2009 12:22:12 GMT
EDIINT-FEATURES: CEM
=_Part_372_22591582.1258028532189
Content-Type: text/plain; charset=us-ascii
This MDN (Message Disposition Notification) was automatically built on
Thu, 12 Nov 2009 12:22:12 GMT in response to a message with id
xxxxxx received from
xxxxx on Thu, 12 Nov 2009 12:22:10 GMT.
Unless stated otherwise, the message to which this MDN applies
was successfully processed.
=_Part_372_22591582.1258028532189
Content-Type: message/disposition-notification
Original-Recipient: rfc822; xxxx
Final-Recipient: rfc822; xxxxx
Original-Message-ID: xxxxx
Disposition: automatic-action/MDN-sent-automatically; processed
Received-Content-MIC: fzj1sSC/z3kmTWhfA6NaIQ==, md5
=_Part_372_22591582.1258028532189-- -
LMS 4.0 Fault Management Module alert doesn't show CurrentUtilization
Hi,
I would like to know if there's a way to show CurrentUtilization percentage within the messages generated by the Fault Management Module in LMS 4.0
EVENT ID = 00008Z1
TIME = S
STATUS = Active
SEVERITY = Critical
MANAGED OBJECT = switch
MANAGED OBJECT TYPE = Switches and Hubs
EVENT DESCRIPTION = HighUtilization::Component=PORT-switch/11150 [Gi3/0/50] [---> TRUNK ];ComponentClass=Port;ComponentEventCode=1057;TrafficRate=5.2261432E7 BYPS;DuplexMode=FULLDUPLEX;UtilizationThreshold=40;MaxSpeed=1000000000;Type
NOTIFICATION ORIGINATOR = Fault Management Module
As you can see above CurrentUtilization percentage is not shown in Event Description section.
Could someone help?
Thank you!
Massimiliano.To my knowledge nothing can be configured here.
You have to take traffic rate and max speed and do the calculation yourself
FAD! functioning as designed
Cheers,
Michel -
Hi All,
We are seeing unidentified traps continuously on the LMS 4.2.3.
Unidentified Trap Generic Trap:6 Specific Trap:1 EnterpriseOid:.1.3.6.1.4.1.9.9.41.2
What are these traps and how to avoid the same. as these traps are coming from all the devices in the network.
Regards,
ChannaHello Channa,
the 'Unidentified Trap' Alerts that you provided :
NOTIFICATION ORIGINATOR = Fault Management Module
The EnterpriseOid in this Alert tells me that this is the cisco syslog trap :
.1.3.6.1.4.1.9.9.41.2.0.1
clogMessageGenerated OBJECT-TYPE
-- FROM CISCO-SYSLOG-MIB
TRAP
VARBINDS { clogHistFacility, clogHistSeverity,
clogHistMsgName, clogHistMsgText, clogHistTimestamp }
DESCRIPTION "When a syslog message is generated by the device a
clogMessageGenerated notification is sent. The
sending of these notifications can be enabled/disabled
via the clogNotificationsEnabled object."
This tells me that you have configured this device with 'snmp-server enable trap syslog' , which means that every syslog message that is generated on the device will also be sent as an snmp trap.
Is there a specific reason why the sending of syslog messages as an snmp trap has been enabled on this device (and others) ?
To stop LMS generating an Alert for every syslog message I would recommend that you disable this device from sending syslog traps to LMS. If there are multiple devices sending syslog traps to LMS then the sending of these traps to LMS should be disabled on all such devices.
Thanks-
Afroz
***Ratings Encourages Contributors **** -
LMS Prime: Disabling Alterts for BRI Interfaces
Hello,
i revceive a lot of Alerts of BRI Interfaces on a router.
EVENT ID = 000072X
TIME = Tue 08-Nov-2011 16:06:44 CET
STATUS = Active
SEVERITY = Critical
MANAGED OBJECT = 192.168.25.4
MANAGED OBJECT TYPE = Routers
EVENT DESCRIPTION = OperationallyDown::Component=IF-192.168.25.4/36 [BR0/0/0:1];ComponentClass=Interface;ComponentEventCode=1075;AdminStatus=UP;DuplexMode=FULLDUPLEX;OperStatus=DOWN;MaxSpeed=64000;Type=DS0;Mode=NORMAL;IsFlapping=false;InterfaceCode=CODEUNKNOWN;LastChang
NOTIFICATION ORIGINATOR = Fault Management Module
how can i get rid of them?
i already searched in Monitor > Fault Settings > Setup > Threshold Settings
but i didn't found where i can disable Operationally Down messages for certain interfaces.
thanks
alexHi Michel,
i tried to modify the tpmgr-param.conf file and added this entry IFDescrPattern-.1.3.6.1.4.1.9.1.1045 *~Bearer Channel*. But still I receive the messages.
#This is an example of how to restrict the creation of ports for a
#specific sysObjectId based on the ifType:
#IFTypePattern-SwitchPort.1.3.6.1.4.1.9.1.501 53
IFDescrPattern-.1.3.6.1.4.1.9.1.1045 *~Bearer Channel*
# Add Fiber Channel port (56) for MDS devices
IFTypePattern-SwitchPort.1.3.6.1.4.1.9.12.3.1.3.380 6|26|56|62|69|117
IFTypePattern-SwitchPort.1.3.6.1.4.1.9.12.3.1.3.376 6|26|56|62|69|117
IFTypePattern-SwitchPort.1.3.6.1.4.1.9.12.3.1.3.375 6|26|56|62|69|117
IFTypePattern-SwitchPort.1.3.6.1.4.1.9.12.3.1.3.414 6|26|56|62|69|117
IFTypePattern-SwitchPort.1.3.6.1.4.1.9.12.3.1.3.411 6|26|56|62|69|117
IFTypePattern-SwitchPort.1.3.6.1.4.1.9.12.3.1.3.442 6|26|56|62|69|117
IFTypePattern-SwitchPort.1.3.6.1.4.1.9.12.3.1.3.612 6|26|56|62|69|117
IFTypePattern-SwitchPort.1.3.6.1.4.1.9.12.3.1.3.719 6|26|56|62|69|117
IFTypePattern-SwitchPort.1.3.6.1.4.1.9.1.475 6|26|56|62|69|117
IFTypePattern-SwitchPort.1.3.6.1.4.1.9.1.407 6|26|56|62|69|117 -
LMS DFM - Wrong Port Alert on 3560-8 Port Switch
Hi,
there is a strange Port Util. Alert from DFM reporting High Util. on Port 1.9 which not exists on this Switch.
Beside this it reports a WS-C3560-49PS but it is a WS-C3560-8 with 8 Ports without PoE:
Here the Alert:
STATUS = Cleared
SEVERITY = Informational
MANAGED OBJECT = SWITCH
MANAGED OBJECT TYPE = Switches and Hubs
EVENT DESCRIPTION = HighUtilization::Component=PORT-SWITCH/1.9 [->cisco WS-C3560-48PS];ComponentClass=Port;ComponentEventCode=1057;TrafficRate=7706065.0 BYPS;DuplexMode=FULLDUPLEX;UtilizationThreshold=65;MaxSpeed=100000000;Type=E
NOTIFICATION ORIGINATOR = Fault Management Module
And here the Switch:
SWITCH#show int status
Port Name Status Vlan Duplex Speed Type
Fa0/1 notconnect 4 auto auto 10/100BaseTX
Fa0/2 notconnect 4 auto auto 10/100BaseTX
Fa0/3 notconnect 4 auto auto 10/100BaseTX
Fa0/4 notconnect 4 auto auto 10/100BaseTX
Fa0/5 notconnect 4 auto auto 10/100BaseTX
Fa0/6 notconnect 4 auto auto 10/100BaseTX
Fa0/7 notconnect 4 auto auto 10/100BaseTX
Fa0/8 notconnect 14 auto auto 10/100BaseTX
Gi0/1 connected trunk a-full a-100 10/100/1000BaseTX
Any idea?
Thanks
Herwigthese switches do not have a fan ...
/* Style Definitions */
table.MsoNormalTable
{mso-style-name:"Normale Tabelle";
mso-tstyle-rowband-size:0;
mso-tstyle-colband-size:0;
mso-style-noshow:yes;
mso-style-priority:99;
mso-style-parent:"";
mso-padding-alt:0cm 5.4pt 0cm 5.4pt;
mso-para-margin:0cm;
mso-para-margin-bottom:.0001pt;
mso-pagination:widow-orphan;
font-size:10.0pt;
font-family:"Calibri","sans-serif";
mso-bidi-font-family:"Times New Roman";}
Compact Switches
Cisco Catalyst 2960-8TC-L
8 Ethernet 10/100 ports; compact size with no fan
1 dual-purpose port (10/100/1000 or SFP)
Cisco Catalyst 2960PD-8TT-L
8 Ethernet 10/100 ports; compact size with no fan
1 10/100/1000 PoE input port
Cisco Catalyst 2960G-8TC-L
7 Ethernet 10/100/1000 ports; compact size with no fan
1 dual-purpose port (10/100/1000 or SFP)
DFM uses the CISCO-STACK-MIB for the fan status; You can poll 1.3.6.1.4.1.9.5.1.2.9 to see what the switch returns. The values can be interpreted using this list from http://tools.cisco.com/Support/SNMP/do/BrowseOID.do?local=en&translate=Translate&objectInput=chassisFanStatus
1 : other
2 : ok
3 : minorFault
4 : majorFault
The reason for this could be BugID CSCsh15007 for IOS 12.2(35)SE; It is fixed in 12.2(35)SE1;
For a solution, you need to upgrade the IOS. -
LMS 4.2 : Temperature OutOfRange
Hello, I keep receiving below alert from LMS:
EVENT DESCRIPTION = OutOfRange::Component=TEMP-1.1.1.1/21856 [module-5 QEng1Sn2(s11)-module-5 QEng1Sn2(s11)];ComponentClass=TemperatureSensor;ComponentEventCode=1079;HighThreshold=40.0 DEGC;Status=OK;CurrentValue=41.0 DEGC;RelativeTemperatureThreshold=20.0 %;entS
NOTIFICATION ORIGINATOR = Fault Management Module
From the alert, i understand that the high threshold is set to 40, but when i checked on N7K i found that this threshold is set differently.
N7K# sh environment temperature
Module Sensor MajorThresh MinorThres CurTemp Status
5 QEng1Sn2(s11) 115 105 41 Ok
Can someone give me insight why this is happening? I assume the device (N7K) will only send the traps only if the temperature exceeding the predefined value which is 105. Now I'm receiving this alert for almost 2000 alert per day. I tried increase the RelativeTemperatureThreshold from 10% to 20% but does not help.
Thnak youI have same issue as well, and my nexus 7000 is using NX-OS ver 5.2.3, shown as below:
Event_Description
OutOfRange
Device IP
10.100.1.2
Device Type
Switches and Hubs
Fault Last Updated At
31-Jul-2012 15:48:03
Component
TEMP-10.100.1.2/21857 [module-5 QEng1Sn3(s12)-module-5 QEng1Sn3(s12)]
Component Class
TemperatureSensor
Component Event Code
1079
Current Value
46.0 DEGC
Event Category
Environment
Event Source
DFM
High Threshold
45.0 DEGC
Relative Temperature Threshold
10.0 %
Status
OK
ent Sensor Value
46 -
Unidentified Trap -unknown bug
An unknown bug which has OID as such:
EVENT ID = 00005CX
TIME = Thu 28-Jun-2012 16:32:13 SGT
STATUS = Active
SEVERITY = Informational
MANAGED OBJECT = Device_Hostnamexxxxxx
MANAGED OBJECT TYPE = Switches and Hubs
EVENT DESCRIPTION = InformAlarm::Component=xxxx.xxxx.com:
Unidentified Trap Generic Trap:6 Specific Trap:1
EnterpriseOid:.1.3.6.1.4.1.9.9.41.2;Description=Generic Trap:6 Specific Trap:1
VarBinds:{ .1.3.6.1.4.1.9.9.41.1.2.3.1.2.544239:LINEPROTO,
.1.3.6.1.4.1.9.9.41.1.2.3.1.3.544239:6,
.1.3.6.1.4.1.9.9.41.1.2.3.1.4.544239:UPDOWN,
.1.3.6.1.4.1.9.9.41.1.2.3.1.5.544239:Line protocol on Interface FastEthernet3/48,
changed state to down, .1.3.6.1.4.1.9.9.41.1.2.3.1.6.544239:975111759 };
NOTIFICATION ORIGINATOR = Fault Management ModuleSo what do we do about these alerts that often get triggered?
Unidentified Trap Generic Trap:enterpriseSpecific Specific Trap:1 EnterpriseOid:.iso.org.dod.internet.private.enterprises.cisco.ciscoMgmt.41.2
Description
Generic Trap:6 Specific Trap:1 VarBinds:{ .1.3.6.1.4.1.9.9.41.1.2.3.1.2.23652:LINK, .1.3.6.1.4.1.9.9.41.1.2.3.1.3.23652:4, .1.3.6.1.4.1.9.9.41.1.2.3.1.4.23652:UPDOWN, .1.3.6.1.4.1.9.9.41.1.2.3.1.5.23652:Interface FastEthernet1/0/39, changed state to up, .
on the interface I have configured "no snmp trap link-status," but I keep getting these info alarms. -
Alerts on administratively down interfaces?
LMS 4.2. I am receiving the alert below in my email inbox. It was my understanding that DFM would not send alerts for interfaces that are shut down. Is this a bug? Has anyone else seen this?
EVENT DESCRIPTION = Unresponsive::Component=192.168.10.5 [142.x.x.x];ComponentClass=IP;ComponentEventCode=1098;InterfaceType=TUNNEL;InterfaceMode=NORMAL;InterfaceAdminStatus=DOWN;Address=192.168.10.5;IPStatus=TIMEDOUT;InterfaceOperStatus=DOWN;NetworkNumber=192.168.10.4;InterfaceName=IF-142.x.x.x/5 [Tu1] [192.168.10.5] [*** Dover Cambar tunnel];
NOTIFICATION ORIGINATOR = Fault Management ModuleI has same events. I don't know how stopping this events. Help?!
Maybe you are looking for
-
Movement Types for Receipt and Consumption
Dear all, I am an ABAPER. My requirement is to develop a Material balancing report. In which i have to display Opening Stock Value Receipt Value Consumption Value Closing stock Closing value for a mater
-
I need a phone number to ring for help
I been a phone number to ring for help to got started with my new iPad thanks
-
Is html5 dnd really supported in WebView?
Hi, While testing dnd support in WebView, I faced a strange behavior regarding the transferable data retrieved. The data is always "*undefined*" in WebView, and is correct under other browsers... Any idea? Workaround? Thanks. Simply load the followin
-
Can't find Slideshow Settings button or pane
Hello, I'm on my way to slideshow to QT to iMovie to YouTube, but I can't find how to set the display time of the slides. The help pages are mentioning things I cannot find. Thank you.
-
How do I get my older copies of photoshop elements 6 & premiere elements 4 to be recognised by Adobe
How do I get my older copies of Photoshop elements 6 & premiere elements 4 to be recognized by Adobe? after re-install on a new computer it seems like the link to Adobe is no longer valid (for registration or update) Message was edited by: GDrex af