NQServer Error OBIPresentation service cannot started.

Hi All,
OBIPresentation service can not started.
I have a error message as below at NQServer log file;
[2013-04-23T23:12:59.000+00:00] [OracleBIServerComponent] [ERROR:1] [] [] [ecid: 004qknFXoTF5uX^5xVH7iW0002z4000001] [tid: 44d7f940] Error Message From BI Security Service: [nQSError: 46164] HTTP Server returned 404 (Not Found) for URL .
[2013-04-23T23:12:59.000+00:00] [OracleBIServerComponent] [ERROR:1] [] [] [ecid: 004qknFXoTF5uX^5xVH7iW0002z4000001] [tid: 44d7f940] [nQSError: 43126] Authentication failed: invalid user/password.
[2013-04-23T23:13:07.000+00:00] [OracleBIServerComponent] [ERROR:1] [] [] [ecid: 004qknGGrHp5uX^5xVH7iW00032O000001] [tid: 40b05940] Error Message From BI Security Service: [nQSError: 46164] HTTP Server returned 404 (Not Found) for URL .
[2013-04-23T23:13:07.000+00:00] [OracleBIServerComponent] [ERROR:1] [] [] [ecid: 004qknGGrHp5uX^5xVH7iW00032O000001] [tid: 40b05940] [nQSError: 43126] Authentication failed: invalid user/password.
And I wrote error message as below at sawlog file;
[OBIPS] [NOTIFICATION:1] [] [saw.sawserver] [ecid: ] [tid: ] Oracle BI Presentation Services are shutting down.[[
File:sawserver.cpp
Line:698
Location:
     saw.sawserver
ecid:
[2013-04-23T23:13:06.000+03:00] [OBIPS] [NOTIFICATION:1] [] [saw.sawserver] [ecid: ] [tid: ] Oracle BI Presentation Services (OBIPS) 11.1.1.6.0 (Build 120104.0800 64-bit) are starting up.[[
File:sawserver.cpp
Line:451
Location:
     saw.sawserver
ecid:
[2013-04-23T23:13:07.000+03:00] [OBIPS] [ERROR:10] [] [saw.security.odbcuserpopulationimpl.initialize] [ecid: ] [tid: ] Authentication Failure.
Odbc driver returned an error (SQLDriverConnectW).
State: 08004. Code: 10018. [NQODBC] [SQL_STATE: 08004] [nQSError: 10018] Access for the requested connection is refused.
[nQSError: 43113] Message returned from OBIS.
[nQSError: 43126] Authentication failed: invalid user/password.
Can you help me?

Make sure your BIPlatform schema user/passwords are valid and try to restart box.
Edited by: Srini VEERAVALLI on Apr 23, 2013 3:48 PM
Update on this to get reply for new posts
Edited by: Srini VEERAVALLI on May 15, 2013 8:00 AM

Similar Messages

  • Cannot start VM - IDE Emulator Failed to Power on with Error 'The service cannot be started, either because it is disabled or because it has no enabled devices associated with it.'

    HI all.
    New install of 2008R2 on HP DL-380 G6.  I have created (several) VM's none of which will start.  If I remove the IDE Hard Disk and add a DVD of the OS ISO, it will boot and start the install (although with no HDD). 
    It seems like the IDE controller is working ok - it is what the DVD drive is using, but it cannot mount a VHD.  The error indicates a driver is not working (although the DVD on IDE works fine) so something to do with VHD?  I can attach the VHD
    in disk management, so it does not seem corrupt - again I have tried with both dynamic and fixed VHDs.
    Full error is:
    'Test1' failed to start. (Virtual machine ID 4320D2D6-DF7E-40D2-BD0F-9562CBB9F052)
    'Test1' Microsoft Emulated IDE Controller (Instance ID {83F8638B-8DCA-4152-9EDA-2CA8B33039B4}): Failed to Power on with Error 'The service cannot be started, either because it is disabled or because it has no enabled devices associated with it.' (0x80070422).
    (Virtual machine ID 4320D2D6-DF7E-40D2-BD0F-9562CBB9F052)
    'Test1': Failed to open attachment 'C:\Users\Public\Documents\Hyper-V\Virtual hard disks\New Virtual Hard Disk.vhd'. Error: 'The service cannot be started, either because it is disabled or because it has no enabled devices associated with it.' (0x80070422).
    (Virtual machine ID 4320D2D6-DF7E-40D2-BD0F-9562CBB9F052)
    Any Ideas?

    Hi ,
    Did  you try to disable the services , if they are exsit :
    HP Smart Array SAS/SATAEvent notification
    HP Insight storage agents
    Then restart your server .
    Best Regards
    Elton Ji
    We
    are trying to better understand customer views on social support experience, so your participation in this
    interview project would be greatly appreciated if you have time.
    Thanks for helping make community forums a great place.

  • OBIEE 11g opmnctl services cannot start (ping failed in ready callback)

    Hi,
    The BI server is up and running
    The platform is Linux, searching forums it's due to /etc/hosts and it is defined as
    127.0.0.1 localhost.localdomain localhost
    127.0.0.1 <servername>.<domain> <servername>
    All OPMN services cannot start with error messages (ping failed in ready callback).
    Any idea is highly appreciated !!!
    Thanks.

    Hi,
    Make sure static ip r u using? If u used to installed dynamic
    Ip it throw this kind off issue . I have face this same issue in obiee11.1.1.3 with dynamic ip address
    Note: u shoud use static ip ( configure look back adopter )
    Thanks
    Deva

  • Secure Socket Tunnelling Protocol Service cannot start

    I'm having problems with my mobile broadband since the Dec 2011 updates cycle.
    Hardware: ASUS F6VE laptop, core2duo, 4 gig ram, ATI graphics
    OS: Microsoft Windows 7 Home Premium 32bit SP1 completely updated to Dec 2011. This install was originally Vista Home Premium 32bit and upgraded to Win7.
    AV:  Microsoft Security Essentials
    The symptoms:
    Error 711:" The operation could not finish because it could not start the Remote Access Connection Service manager in time."
    Rasman cannot start because Secure Socket Tunnelling Protocol service cannot start.
    The system log is now filling up with:
    7001: "The Remote Access Connection Manager service depends on the Secure Socket Tunnelling Protocol Service service which failed to start because of the following error:
    The operation completed successfully."
    and
    7036: "The Secure Socket Tunnelling Protocol Service service entered the stopped state."
    Attempting to open the properties of the dialup adaptor gives an error dialog box:
    Title:"Network Connections"; Message:"An unexpected error occurred." Removing the existing connections and trying to reinstall the modem made no difference.
    The issue is specific to the dial up / mobile broadband though as the Ethernet still works fine. The mobile broadband stopped working when I let the December 2011 Windows Updates install. It was fine till then - I'd been using it all day before applying the
    updates that night. The only odd thing that I will say is that for a few weeks now, occasionally Windows would occasionally not detect the display, keyboard and track pad on first boot, but restarting generally was successful. Then just when I started up the
    PC to download the hot fixes, the Windows detected "new hardware" and reloaded drivers for the ACPI x86 based PC (i.e. the HAL driver) and a few others that I wasn't quick enough to note. I've never seen that happen before, but now the hardware is being set
    up correctly each boot and seems to behave apart from SSTP service is broken.
    Rolling back to a previous restore point did not fix it, nor did uninstalling the hotfixes.
    I've tried pretty much every fix that I have been able to find and none are successful.
    The "fix" by removing sstpsvc as a dependency in the RasMan registry key was unsuccessful.
    The "fix" by deleting the contents of %system32%\Logfiles\WMI and %system32%\Logfiles\WMI\RtBackup was unsuccessful
    The "fix" by reregistering netshell.dll and ole32.dll successfully registered for the former, but not ole32.dll. The problem was not fixed.
    "sfc /scannow" only finds the autochk.exe hash issue, which has been a present for some time.
    I will mention that I had VMWare Workstation 7.1.4 installed. I tried to uninstall it a while back, but it broke another program that I need - probably something to do with the sentinel driver. I have now uninstalled VMWare and reset the TCP/IP stack without
    issue. The problem was not fixed though.
    I really don't want to reinstall as it's taken me quite some time to get it set up as I want it

    You don't need to start the services you just need to make sure that the startup type is set to manual.
    The service itself will start when needed.
    This message here is not an error or problem, it is just telling you that service is not being used by anything on your computer.
    SSTP: "The Secure Tunnelling Protocol Service on Local Computer started then stopped. Some services stop automatically if they are not in use by other services or programs."
    What exactly are you trying to do that requires this service (SSTP)?

  • U530 Touch - Audio DRIVER ERROR - This device cannot start (Code 10) - Windows 7

    U530 - High definition audio device - ERROR - This device cannot start (Code 10) Windows 7, please see the picture
    Picture link (hosted on photobucket.com)
    I got all drivers up to date including the BIOS, everything is working fine (the sound works, microphone works...) but this error is kind of annoying to my eyes so if anyone know how to fix it please help.
    I tried to uninstall this and let windows update install it again => not worked, same problem.
    I tried to re-install the Realtek driver (uninstall - restart machine - install - restart machine) => same problem
    And another probelm which has not been solved yet is the Bluetooth icon keep blinking on battery mode (windows 7), you can see more in this thread

    What kind of reinmstall did you perform?  If you used the recovery media, then this will be pretty simple. Boot to the recovewry media again and this time select the Reinstall drivers and applications option. Find the audio driver on the list of available drivers, put a tick in the box to its left and then click on the install button in the lower right hand corner of the window. The driver will be installed.  Your list will be different than the following one, but this is only an example. 

  • HT201272 I purchased the August 2012 edition of Consumer Reports and I get an (Error During Download Cannot start the download because the file is missing or invalid)

    I purchased the August 2012 Edition of Consumer Reports and I get (Error During Download Cannot start the download because the file is missing of invalid)

    Contact support and see if they cna give you a fresh copy. It's probably with the file..

  • In running the datalgr example, I get the error NIDAQ32.dll cannot start.... then program exits. Version of NI DAQ is 6.9.2, using MS C++.

    In running the datalgr example, I get the error NIDAQ32.dll cannot start.... then program exits. Version of NI DAQ is 6.9.2, using MS C++.

    Since this is a DAQ question more than a Measurement Studio for VC++ question, I'd recommend you repost it to the DAQ forum.
    Cheers,
    Azucena

  • I've been getting this error message Lightroom cannot start because it cannot create files in the temporary file location.

    I've been getting this error message Lightroom cannot start because it cannot create files in the temporary file location “/var/folders/lK/lKbPbq2OF0aPCbMnDc erE   TI/-Tmp-”
    I've also been getting others errors about cannot create or modify temporary files when trying to install other programs.  Also some of my documents on my computer will not open and crash. 
    Any help would be helpful.
    I've tried doing this as read not sure if it helps:
    ls -Odel $TMPD
    This is what I had in response:
    drwxr-xr-x  36 root  admin  - 1224 Dec  9 00:29 /var/folders/lK/lKbPbq2OF0aPCbMnDc+erE+++TI/-Tmp-/

    Which os version are you using? 
    What is Lighthouse? 
    Please describe in detail all you have attempted to do in order to resolve the issue. 

  • HTTP Server error - service cannot start

    I have installed Oracle 9i on NT. After installation when tried to start the HTTP Server it gave an error cannot start. Any idea how to solve this error?
    Thanks
    Alina

    start the services
    Control Pannel,Setting,Administrative Tools,Services
    and start the HTTP Services.
    if already started.
    Start Form Builder and
    then edit -->prefrence-->runtime-->set default,
    change port from 8888 or 8889 to 80 or set port of his computer.
    any other solution is also avilable. if problem not solved. againt contact to
    [email protected]

  • PCMCIA Wlan card is not detected: Error 1058: service cannot be started

    PLEASE HELP!
    I am running WXP Pro for over 2 years and I have been connecting to the internet via a wireless pc card in my laptops PCMCIA slot with no problems. Suddenly last week it started to randomly disconnect and reconnect, and now it has gone off completely.
    I bought a new WiFi card and still didn't work. I have checked the device manager and the PCMCIA cardbus driver is working fine as is every other device. The wireless card driver and some other network related drivers fail to start no matter what I try and how many times I try. I have tried another laptop and both my old card and the new one work fine.
    All the device driver that I try to start have the error
    "Error 1058: The service cannot be started, either because it is disabled or because it has no enabled devices associated with it."
    The card driver is installed, just not starting, it's like the laptop cannot detect or see the card in the slot
    Please help; I am having trouble finding anyone with the same problem after a week of searching the web.

    Hi
    This behavior can occur if the service is disabled or if the service is disabled for the hardware profile that you are currently using.
    To enable the service do this:
    1. Click Start, point to Programs, point to Administrative Tools, and then click Services.
    2. Double-click the service that did not start.
    3. Click the Log On tab.
    4. Verify that the service has not been disabled for the hardware profile that you are using. If it has, click Enable.
    5. Click the General tab. Verify that the service has not been disabled in the Startup Type box. If it has, click Automatic to have it start when you start the computer.
    This was described here in the MS knowledge base article
    http://support.microsoft.com/kb/241584

  • Error: The DataFinder cannot start due to an internal error

    Hello,
    I get the same error message every time I reboot my Win 7 PC:
    "National Instruments DataFinder"
    "The DataFinder cannot start due to an internal error."
    "Please wait till the National Instruments DataFinder Index Service is running and try starting the DataFinder again, or reboot your computer. "
    I tried finding a DataFinder Index Service in the Control Panel --> Admin,istrative Tools --> Services, as mentioned in this post http://forums.ni.com/t5/LabVIEW/Error-244-The-DataFinder-cannot-start-due-to-an-internal-error/td-p/...,
    but there was none such listed service:
    I cannot find any mention of a DataFinder or a DataFinder Index Service anywhere else on my PC. Can you please help to find out where this error is coming from and how to fix it? As far as I am aware, I do not use this DataFinder. Thanks!
    Regards,
    Brandon

    Hello BrandonVonk,
    The toolkit wouldn't show up in your installed programs list as it is more like a plugin to LabVIEW. Instead, pull up NI License Manager and go to Local Licenses > LabVIEW XXXX > Toolkits and see if it is listed amongst the toolkits you have installed. There should be a geen box next to it to indicate that it has been installed and activated.
    Hope this helps,
    Siana A.
    Application Engineering
    National Instruments

  • OracleDBConsole service cannot start

    Hi all,
    I installed Oracle 11g software on a Windows XP SP2 machine with 1 GB RAM.
    I then used DBCA to create a db and in the end of the db creation the following error raised:
    error screenshot: http://www.ahmedbaraka.com/temp/error.jpg
    logfile URL: http://www.ahmedbaraka.com/temp/emConfig.log
    After many attempts to use emca to create the EM repository, I noticed the problem is in starting the OracleDBConsole service. This service cannot be started by Windows. When I refer to the Even Log, I see the following error: "Process exited abnormally during initialization."
    <b>Did any one face this problem when installing Oracle 11g? Is there any suggestiong to try to fix it?</b>
    Thanks in advance.

    Hi all,
    I installed Oracle 11g software on a Windows XP SP2
    machine with 1 GB RAM.
    I then used DBCA to create a db and in the end of the
    db creation the following error raised:Sorry I have not checked your screen shots. My question is did you install 11g with the standard database and then created a new DB (second DB) with DBCA or you installed Software Only?
    One thing to check is whether you have got 2 listeners. The first listener would be created successfully, but the second will fail because Oracle will try to allocate the same port it gave to the first listener to the second listener.

  • FE service cannot start after the update was done

    Hi,
    We are installing lync 2013 standard Edition server on windows server 2008 R2.
    Certificates are public ones and they are from Digicert.
    We managed to go to step 3 (certificates part is ok).
    We cannot start the FE service.
    We tried everything regarding resetting fabric state, registrat  etc.
    We made the update with the newest patch (February 2015).
    FE cannot be started:
    We still got the errors:
    "Failed to sync data for Routing group {19F4D868-D0A1-53D8-BE89-1BFA7BDE645E} from backup store.
    Cause: This may indicate a problem with connectivity to backup database or some unknown product issue.
    Resolution:"
    "This process was not able to update its health status
    The Audio-Video Conferencing Server failed to send health notifications to the MCU factory at.."
    and so on...
    as could be seen under link: http://troubleshootinglync.blogspot.com/2014/03/lync-2013-front-end-service-wont-start.html
    Any idea what could be wrong?

    Hi iron_folower,
    You can follow the steps below to troubleshoot your problem:
    1. Install the Root Certificate and the Intermediate Certificate from Digicert.
    2. From:
    https://social.technet.microsoft.com/Forums/lync/en-US/506821e2-d3fe-42bd-a6dc-daed6c5f0df6/the-audiovideo-conferencing-server-failed-to-send-health-notifications-to-the-mcu-factory-at?forum=ocsconferencing
    Try to create the REG key:
    HKLM\System\CurrentControlSet\Control\SecurityProviders\SCHANNEL and create a dword entitled
    Sendtrustedissuerlist with a hax value of 0.
    3. Reinstall the base OS features:
    Import-Module ServerManager
    Add-WindowsFeature Web-Dyn-Compression,desktop-experience,RSAT-ADDS,Web-Server,Web-Scripting-Tools,Web-Windows-Auth,Web-Asp-Net,Web-Log-Libraries,Web-Http-Tracing,Web-Stat-Compression,Web-Default-Doc,Web-ISAPI-Ext,Web-ISAPI-Filter,Web-Http-Errors,Web-Http-Logging,Web-Net-Ext,Web-Client-Auth,
    Web-Filtering,Web-Mgmt-Console,Msmq-Server,Msmq-Directory
    Best regards,
    Eric
    Please remember to mark the replies as answers if they help, and unmark the answers if they provide no help. If you have feedback for TechNet Support, contact [email protected]

  • Can't get my desktop PC Win7 MS Ofc 2010 calendar, contacts, tasks onto iCloud.  Get error message: Setup cannot start because of unexpected error". Laptop Win8

    I have a desktop PC Win7 with MS Ofc 2010.  I have iCloud on Macbook, Laptop Win 8 with MS Ofc 2013, iPhone synched.  I cannot get iCloud to accept the Outlook, Calendar, Contacts, Tasks with checking the box and starting the upload. 
    Error Message:  Setup cannot be started because of an unexpected error.  Should I delete iCloud and reload and try again?  What are suggestions from the community?   Sent report to iCloud.

    Hi Clifford,
    Take a look at the article below, it provides tips that should help you resolve the iCloud setup issue.
    iCloud: iCloud Control Panel setup cannot be started
    http://support.apple.com/kb/TS5178
    Symptoms
    After installing or upgrading to iCloud Control Panel 3.0, iCloud setup cannot complete.
    Resolution
    You may see one of several messages. Your troubleshooting steps will differ depending upon the message:
    “Your setup couldn't start because your username or password is incorrect. Go to the iCloud Control Panel, sign out, and sign back in.”
    Click Cancel to close the message.
    Click "Sign out" on the iCloud Control Panel.
    Reenter your Apple ID and password, then click Sign in.
    “Your setup couldn't be started because the iCloud server stopped responding.”
    or “Your setup couldn't be started because the iCloud server couldn't be reached.”
    Check the System Status page to make sure there aren't any issues affecting the settings you've chosen in iCloud Control Panel. If you are setting up iCloud for use with Outlook, check that there aren't any issues with Mail, Contacts, Calendars, or Reminders.
    Make sure your computer is online. In a browser, attempt to view www.apple.com and iCloud.com. If you can't connect to the Internet, your iCloud contacts, calendars and tasks cannot be added to Outlook. If you're using Windows 8, review the instructions for resolving network problems. If you're using Windows 7, review the instructions for troubleshooting internet connection issues.
    “Your setup couldn't be started because of an unexpected error.”
    Apple is investigating this issue. This article will be updated as more information becomes available.
    -Jason

  • Game Port Error: This device cannot start. (Code

    I recently did a PC rebuild and have a fresh install of XP SP2. When trying to play with a gamepad that worked just fine before the reinstall of XP, it shows the game port as not working.
    Sure enough, Device Manager shows a problem with the game port.
    I uninstalled the game port and reinstalled it to no avail.
    This is the error the properties of the game port has listed:
    This device cannot start. (Code 0)
    Anyone have any idea how to fix this - I saw several posts in this forum from some time ago with no answers.
    Thanks in advance!

    What kind of reinmstall did you perform?  If you used the recovery media, then this will be pretty simple. Boot to the recovewry media again and this time select the Reinstall drivers and applications option. Find the audio driver on the list of available drivers, put a tick in the box to its left and then click on the install button in the lower right hand corner of the window. The driver will be installed.  Your list will be different than the following one, but this is only an example. 

Maybe you are looking for