OM / PD Infotype Screen modification

Hi All,
We have a requirement where we need to change or hide fields for OM or PD infotypes.
I checked all the tables and fields to do the same as the way its possible for the PA infotypes but no options available.
I found that only options would be changing the standard screen using the access key or the options using BADI's
Appreciate if anyone can suggest any other ways to make the above changes.
Thanks in advance.
YM

Hi Manoj,
Thanks for your reply.
With the above tables mentioned, we will not be able to modify the fields.
For Ex: I need to hide certain fields in standard OM/PD infotypes.
Hi Debjani,
Thanks for your reply.
if possible can you please provide more details.
Cheers
YM

Similar Messages

  • Infotype 0071 - Screen Modifications

    Hi SAP - gurus,
    I would like to hide few fields in infotype 0071 - Pension Funds GB.  I am not able to find the  fields in the screen modifications table.  Can you let me suggest me how I need to go about this??
    Thanks in advance for your help.
    Regards,
    Lakshmi

    Hi Dilek,
    Thanks for your quick response.  I am checking in Module Pool - MP007100 Variable key - 05 since we have not configured the Pension schemes as Flat, Percentage or Mixed.
    Pls let me know your suggestions.
    Regards,
    Lakshmi

  • How to add new field to Screen Modifications

    Hi,
    I want to get P0002-CNAME in screen modifications of Infotype 02. At present i have other 23 fields for which i can set display attributes. This new field is to be added in infotype 02 and also some coding is to be put for this. How this can be achieved ?
    One solution is to enhance infotype and add some Z field,but i would like to use the existing structure field.
    Please let me know proper way for this.
    Thanks.

    Hi,
    I want to get P0002-CNAME in screen modifications of Infotype 02. At present i have other 23 fields for which i can set display attributes. This new field is to be added in infotype 02 and also some coding is to be put for this. How this can be achieved ?
    One solution is to enhance infotype and add some Z field,but i would like to use the existing structure field.
    Please let me know proper way for this.
    Thanks.

  • Feature to default values on infotype screens

    Hi All,
    Could I use a Feature (txn PE03) to determine the default values on an infotype screen?
    For example, I want the value in field FUNKT on Infotype 34 to default to say 'KLMN' if the Employee Group is '1' and the Emp. sub group is 'Z5'.
    I would like to use the screen modification config (table T588M) to assign the Feature and get the values without coding.
    I know I can achieve this by using a subroutine on dynamic actions or a BADI for infotype processing etc. but I am lazy and don't want to code if I can avoid it.
    Many thanks in advance
    Sanjay

    Thanks Sarika.
    I can create a Feature in PE03 but how do I use that in the config (table T588M)? Because if I am not able to use it in the config, I will be forced to code (using any Fn. Mods of the likes of HRFEATUREBACK*).
    The Feature ABKRS doesn't seem to be specified in table T588M as such there is bound to be coding behind it in the IT0001 processing programs.
    Cheers,
    Sanjay

  • HR Infotype Screen Programming!

    Hi All,
    I have a text field in my infotype screen which is editable.
    By default, the enteries are in CAPS.
    What do i need to do, if i want the field to accept "Caps" and small letters aswell?
    Thanks in advance for all the responses.
    Regards,
    Sundar.

    Sundar,
    If you are working with a standard SAP infotype, fields and Screens, this change is considered a modification.
    The other thing that you should check is if your field is tied to something defined in the data dictionary, then upper/lowercase is also attached to the domain of your field definition.  Changing it only on the screen may not necessarily populate the field with upper/lowercase.
    If you click on the "definition" tab of the domain definition you will see a checkbox called upper/lower case.
    Best Regards,
    Chris H.

  • Copy Standard infotype screen for country purpose

    Hi,
    I am trying to copy the Standard screen (2007) for the infotype IT0002 to make some country specific modification.
    However I am not able to copy the standard screen as it is asking for the Access Key.
    Can you please suggest if there is a way to copy the standard infotype screen without providing the access key.
    Regards
    Bharath

    Hi,
    Why don't you just enhance the infotype via PM01 - Enhance single screen?
    (MP000200 screen 2007)
    Regards,
    Dilek
    Edited by: Dilek Ersoz Adak on Feb 8, 2010 6:53 PM

  • Screen Modifications

    hi,
    for any global implementtion prj, if i wanted to have different fields in the infotypes, how to do this using screen modifications? and also what is the purpose of variable key in  Change view " Infotype Screen Control"
    for ex for US in IT0001, i wanted to hide Contract Field, for other country i wanted to dispay that field in IT0001.
    Thanks

    Hi Novice,
    When you press F1 in any field you will get technical information.by pressing F9 or clicking the technical information icon.
    Gather the information on program name and screen number. Table name and field name.
    In IMG  under personnel management -> personnel administrationt-> ustoming User interfaces->Change Modifications ->
    Select your module pool  Screen and Feature that is Table like IN case of infotype 0002 it is P0002 and select details
    You will find radio button to hide the fields.
    Warm REgards,
    Kapil

  • Screen Modifications Recruitment Module

    Dear All,
    I wanted to make screen modifications for Intial entry of basic data's initial screen and even organisational assignment and other recruitment infotypes. But unable to find any pertaining to them. Can any one suggest me on this...
    Regards,
    Rajasekar

    Hi,
    Check feature MASSN via PE03: Determining the Fast Entry Dialog Module.
    And check the return value in table TDCT, you will find the screen and program call by PB40 Initial Entry of Applicant Data.
    And you can create your own dialog module to adjust the initial screen or change the exist one.
    Hope helps,
    Chen Jian

  • Re:Screen Modifications

    Hai Experts,
    we are doing screen modifications for infotypes that we can use through PA30,
    i want to know whether its possible to make screen modifications while performing actions(pa40),
    if possible what is the procedure.
    Regards,
    Chiran Reddy.

    Hai Navneet,
    Thank you for your reply,i want to know that if we perform any screen modifications througgh module pool program,its impact will be both on pa30 and pa40 also.
    my requirement is that in an infotype
    some fields will be active while hiring
    same fields will be inactive while promotion
    same fields will be hidden while transfer.
    for the above process,is there any solution.
    Regards,
    Chiran Reddy.
    Edited by: chiran reddy on May 9, 2008 6:14 AM

  • Add ifnotype field to an Infotype Screen Control for Infotype 0006

    How do I add an infotype field to an Infotype Screen Control for Infotype 0006. We need to add an additional Field for mobile phones. I have lloked in screen control (V_T588M) with no joy.
    Edited by: Henry Manana on Sep 1, 2010 12:11 PM
    Edited by: Henry Manana on Sep 1, 2010 12:12 PM

    You may copy your current screen into a new screen (e.g. 2099) for MP000600 and add the 2 fields into the element list as well as the screen layout of screen 2099. Then set an appropriate Modification Group 3 to these 2 fields in T588M detail screen for screen 2099. Configure feature P0006 and table T588M to set screen 2099 for molga 16.

  • Module Pool MP000200_CE in Screen Modifications

    Hello,
    My query is regarding screen modifications table T588M. When the module pool MP000200_CE is used? I know it is used when the Concurrent Employment is active and we have activated Concurrent Employement in our system but when I go to the system - status in IT0002 and check the screen number, it shows MP000200 and not MP000200_CE.
    How to activate the screen MP000200_CE for IT0002?
    Thanks.

    For the infotype 0002 for the modulepool MP000200_CE, only screens
    2007 and 2010 are needed. concerning the infotype 0002: the corresponding modulepool (MP000200 or MP000200_CE) will be read according to the country and the table T582ITD. If no entry exists for this country then the modulepool MP000200 will be used for the infotype 0002.

  • Country specific Screen Modifications

    Hi,
    I have a requirement for IT0007 where the time administraors field is an optional one for Portugal and a required field for Spain.
    This need to done through 'Change Screen modifications' but how to differentiate between countries.
    Please suggest.
    Thanks,
    Tara

    I have a requirement for IT0007 where the time administraors field is an optional one for Portugal and a required field for Spain.
    This need to done through 'Change Screen modifications' but how to differentiate between countries.
    Hi,
    Step 1:
    Goto PE03
    P0007 feature
    Add molga Portugal 19 ansd spain 04
    enter the return values for the respective countries.
    Step2:
    Sm30-->v_T588m
    select the module pool MP000700
    copy the standard screen with diffrent variable keys (return values of feature P0007)
    make the settings of the fields accordingly.
    But i Guess Time administartor field is in 0001 infotype which you need follow the same procedure for P0001 and MP000100.
    There is no time adminstrotor field in 0007.
    if its is customized then you need to map z module pool in T588m and create zfeature.

  • Selection screen modification based on various buttons in selection screen

    Hi,
    I have 1 query related with Selection screen modification.
    In my Report Program,I have created GUI Status for my selection screen
    Now 2 buttons in application toolbar are coming on selection sceen.
    For this i used,'At selection screen output' event.
    And there are 2 blocks on selection screen.
    If user press button1 then block2 should not display.
    and if user press button2 then block1 should not display.
    but the problem is i m not getting reqd result and also while doing debugging its not showing me sy-ucomm value.
    Any pointers on this.
    Thanks,
    Mamta

    Hi Mamta,
       have it in a group then you can write code accordingly see sample example,
    SELECTION-SCREEN BEGIN OF LINE.
    PARAMETERS       : p_r1 RADIOBUTTON GROUP rad
                            USER-COMMAND clk DEFAULT 'X'.            " upload Radio Button
    SELECTION-SCREEN COMMENT 5(35) text-003.
    SELECTION-SCREEN END OF LINE.
    SELECTION-SCREEN : BEGIN OF BLOCK 001 WITH FRAME TITLE text-001.
    PARAMETERS: p_upl       LIKE rlgrap-filename MODIF ID a           "Upload File
                             DEFAULT 'c:\temp\parbmat.xls',
                p_werks     like t001w-werks MODIF ID a,              "Plant
    PARAMETERS: p_rest      LIKE rlgrap-filename MODIF ID a           "Dwonload File Path
                             DEFAULT 'c:\temp\Success.xls'.
    SELECTION-SCREEN : END OF BLOCK 001.
    SELECTION-SCREEN BEGIN OF LINE.
    PARAMETERS : p_r2 RADIOBUTTON GROUP rad.
    SELECTION-SCREEN COMMENT 5(35) text-004.
    SELECTION-SCREEN END OF LINE.
    SELECTION-SCREEN : BEGIN OF BLOCK 002 WITH FRAME TITLE text-002.
    PARAMETERS     : p_plant  LIKE marc-werks MODIF ID b.                "Plant
    PARAMETERS     : p_lgort  LIKE mard-lgort MODIF ID b.                "Storage Location
    PARAMETERS     : p_vkorg  LIKE mvke-vkorg MODIF ID b.                "Sales Organization
    PARAMETERS     : p_vtweg  LIKE mvke-vtweg MODIF ID b.                "Distribution Channel
    SELECT-OPTIONS : s_mat FOR  mara-matnr MODIF ID b.                  "Material No No
    SELECT-OPTIONS : s_dat FOR  mara-ersda MODIF ID b.                  "Date on Record Created
    PARAMETERS     : p_down LIKE rlgrap-filename MODIF ID b
                      DEFAULT 'c:\temp\Material Master.xls'.           "Download File Path
    SELECTION-SCREEN : END OF BLOCK 002.
    AT SELECTION-SCREEN OUTPUT.
    *Inactive Fields depending on the radio button
      LOOP AT SCREEN.
        IF p_r1 = 'X'.
          IF screen-group1 = 'B'.
            screen-active = 0.
          ENDIF.
        ELSEIF p_r2 = 'X'.
          IF screen-group1 = 'A'.
            screen-active = 0.
          ENDIF.
        ENDIF.
        MODIFY SCREEN.
      ENDLOOP.
    Edited by: suresh suresh on Jul 28, 2009 12:42 PM
    Edited by: suresh suresh on Jul 28, 2009 12:42 PM

  • Is it possible to hide the detail for a field in infotype screen for users

    Hi,
    My requirement is that.
    1) For a group of users in IT0002 screen the content of SSN field would be shown as XXXXX where for some users it will show the actual value in PA20,PA30. This is not MOLGA specific, this would be user specific.
    Is it possible to do that. I was trying with the exit ZXPADU01 but not working. I believe T588M will also not work in that case.
    Please suggest on that.
    Thanks & Regards,
    Sandip

    Hi,
    Instead of presenting the SSN as XXXX, you can simply hide the field using screen modifications and feature P0002. The key here is using field group USERG (user group) in the decision tree. The prerequisite is assigning the set of users to a user group (UGR parameter) through SU3. That value will be the return value under USERG in the feature.
    Hope this helps.
    Donnie

  • Hide "Administratior" in IT 0001 through screen modification

    Hi Gurus,
    I have requirement where client wast us to hide Administrator section which have three administrators field from IT 0001. Please help me to understand that is it possible through screen modification.
    If not then what is the other solution?
    Regards,
    Amit Jain

    Hi Subhash,
    FIrst go to the IT001 screen... go to SYSTEMS -
    STATUS and get the program name and screen number
    then on
    Go to SPRO..
    Personnel Management > Personnel Administration > Customizing User Interface > Change Screen Modification >
    Select the program name and screen number which you got from IT0001
    then click on magnification screen and select the Hide radio button for ADMINISTRATOR field.
    Hope this helps...
    Ajay