%ONLINE-SP-6-REGN_TIMER: multiple line cards down after config change

Hi,
I was wondering if someone could help.
I recently changed the entire configuration on two 6509 switches, and the fibre modules on slot 7 and 8 have gone down on BOTH switches. It would be easy to say that its a hardware fault but I cannot understand how module 7 and 8 can go down on both switches. Initially I thought it maybe due to IOS bug 22-33.SXI2a.bin" so I upgraded it to s72033-advipservicesk9_wan-mz.122-18.SXF12a.bin but it still down.
These are the actions I have carrried out to try resolve the issue:
- Reverted back to orginal configs but no luck
- Tried to use "power enable" command but the status light on both modules seems to turn red and then go off again.
- I have also tried to put one of the fibre modules into a different slot but no joy
- Upgraded the IOS from 22-33.SXI2a. to 122-18.SXF12a
I am running out of ideas.. can anyone help ? I am sure that hardware fault cannot occur on BOTH modules 7 & 8 on BOTH switches after config change.
The error in the log shows that modules "failed to bring online because of registration timer event". I understand this means that it is unable to download the image within the allocated time.. maybe I could manually copy the image onto the line card if that is possible ?? any ideas ?
Daughterboard         WS-SUP720          SAL135063V2  4.0    Ok
  7  Centralized Forwarding Card WS-F6700-CFC       SAL1419HKJK  4.1    PwrDown
  8  Centralized Forwarding Card WS-F6700-CFC       SAL1419HAG0  4.1    PwrDown
Mod                                                      Hw    Fw           Sw           Status
  7  5475.d016.075c to 5475.d016.075f   3.1   Unknown      Unknown      PwrDown
  8  5475.d0bb.7404 to 5475.d0bb.7407   3.1   Unknown      Unknown      PwrDown
System image file is "disk0:s72033-advipservicesk9_wan-mz.122-18.SXF12a.bin"
BOOT variable = disk0:s72033-advipservicesk9_wan-mz.122-18.SXF12a.bin,12;sup-bootdisk,1;
CONFIG_FILE variable =
BOOTLDR variable =
Configuration register is 0x2102
Standby is not present.
May 28 17:25:10.352: %C6KPWR-SP-4-DISABLED: power to module in slot 7 set off (Module  Failed SCP dnld)
May 28 17:25:10.452: %ONLINE-SP-6-REGN_TIMER: Module 8, Proc. 0. Failed to bring online because of registration timer event
sm(cygnus_oir_bay slot8), running yes, state wait_til_online
Last transition recorded: (disabled)-> disabled (disabled)-> disabled2 (restart)-> wait_til_disabled (timer)-> may_be_occupied (timer)-> occupied (known)-> can_power_on (yes_power)-> powered_on (real_power_on)-> check_power_on (timer)-> check_power_on (power_on_ok)-> wait_til_online
May 28 17:25:10.452: %C6KPWR-SP-4-DISABLED: power to module in slot 8 set off (Module  Failed SCP dnld)
May 29 11:41:16.601: %SYS-5-CONFIG_I: Configured from console by console

Would anyone know if the line cards are maybe failing due to Embedded Event Manager configuration ? The person who configured this lab has left the company so I am not sure what the EEM configurations actually mean.
The reason i am suspecting the EEM configuration is because the error in the log seems to suggest the module failed due to registration timer event.
May 30 14:47:00.366: %ONLINE-SP-6-REGN_TIMER: Module 8, Proc. 0. Failed to bring online because of registration timer event
Just trying to check all the possibilities as I have tried everything else,
event manager directory user policy "disk0:/fcp_eem"
event manager directory user repository tftp://10.11.x.x/xxx/
event manager scheduler script thread class default number 10
no event manager policy Mandatory.go_switchbus.tcl type system
event manager policy rp_test.tcl type user
event manager detector rpc ssh acl 60 event manager directory user policy "disk0:/fcp_eem"
event manager directory user repository tftp://10.11.216.145/FCPD/
event manager scheduler script thread class default number 10
no event manager policy Mandatory.go_switchbus.tcl type system
event manager policy rp_test.tcl type user
event manager detector rpc ssh acl 60

Similar Messages

  • 7k vPC best practice with multiple line cards?

    I have a pair of 7k's that have a single line card with a 2 port vPC linked to a pair of 5k's, another 2 port vPC linked to the layer 3 VDC and a 4 port vPC used for peer link.  I recently added an additional line card to the 7k’s and want to add redundancy for the new line card.  Would it be best to simply remove one of the existing ports from each vPC on line card 1 and then include a port from the new line card?  For the peer link, my thought was to remove two ports from the existing port channel and then add back 2 ports from the new line card.  This way line card 1 and 2 will share the ports that make up the vPC’s instead of all of the vPC ports being on line card 1.  Does that make sense or is there a better way to implement line card redundancy after adding a new line card? 
    Also, if I want to add some of the ports on line card 2 to the layer 3 VDC.  Can I run the allocate interface command without the fear of it removing any existing allocated ports?  I understand that the ports being moved/allocated to a different VDC will lose their current configuration.  I had a bad experience years ago using "switchport trunk vlan allowed" vs. "switchport trunk vlan allowed add" command so I just want to make sure the allocate interface doesn't require the "add" option!  :)
    Thanks!      

    Hi,
    For adding new interface to port-channel:
    1. you can shutdown the new physical interface and put all the configure as existing member interface.
    2. add as port-channal member.
    3. Unshut the physical interfaces (new interface- module 2).
    4. Shutdown the physical interfaces (module 1) which you wanted to remove from the port-channel 
    Moving interface from one VDC another VDC will erase the configuration on that  interface  . you could use allocate interface command to add new interface to the VDC but all the interface should be in same port group. Adding new interface to vdc will not affect existing interface configuration  .
    HTH
    Regards,
    VS.Suresh.
    *Plz rate the usefull posts *

  • Macbook pro retina shutting down after computer changes graphic card

    My 15 inch (Mid 2012) Retina MacBook Pro has recently started to shut down. I realized it was because of the change from using the Intel HD Graphics 4000 to the NVIDIA GeForce GT 650M. This would happen if I were to play around with the energy savings buttons or run something that requires a lot of power. After shutting down, it would restart with a black screen and will proceed to do nothing. The computer is still on though as I can still hear error noises when pressing the keyboard. It would normally require me to wait 15 minutes and turn it on after resetting RAM and SMC. I know that it isn't related to updating to the latest version of Mavericks as I was still able to run some heavy duty apps after installing it.
    Processor  2.3 GHz Intel Core i7
    Memory  8 GB 1600 MHz DDR3
    Graphics  Intel HD Graphics 4000 1024 MB
    Software  OS X 10.9.5 (13F34)
    Storage  250GB

    I just ran a few tests to confirm my suspicion that this is a sleep problem for me and found that my rMBP will restart as soon as it has entered the sleep cycle.  Set it to auto sleep after 10 minutes and it will restart at 10 minutes, set it to sleep at 3 minutes and it will restart at 3 minutes.  Command it to sleep and it will restart.
    So for me at least there is a workaround and that is to set sleep to "never".  The display still sleeps but my mac keeps running.  So that's not a solution but it is a workaround, and if I want it to shutdown and not restart I either hold the powerbutton or take off the power cable and choose shut down from the dropdown menu (it won't restart on battery power, it'll just shut down).
    I hope that helps someone else!  And I hope it helps the engineers to diagnose and actually solve the very long running problem for us all..

  • SOA EM down after password change - OracleSystemUser is not a valid user principal in the current security realm

    Hello,
    I've got a SOA Suite development environment set up and whilst trying to change the weblogic password using this tutorial a problem arose with my soa managed server.
    Firstly I was unable to start the Managed SOA server due to mismatching passwords, and after I modified the boot.properties file, now I cant start the usermessagingserver and soa_infra applications due to the following error:
    Error 1
    Getting weblogic deployment manager.
    Got weblogic deployment manager.
    Invoking Start Up operation.
    Start Up operation for application usermessagingserver on target soa_server1 RUNNING.
    Start Up operation for application usermessagingserver on target soa_server1 FAILED.
    weblogic.application.ModuleException: Exception preparing module: EJBModule(sdpmessagingclient-ejb-parlayx.jar)
    Unable to deploy EJB: MessagingClientParlayX from sdpmessagingclient-ejb-parlayx.jar:
    The run-as security principal, 'OracleSystemUser', chosen for the EJB 'MessagingClientParlayX(Application: usermessagingserver, EJBComponent: sdpmessagingclient-ejb-parlayx.jar)' is not a valid user principal in the current security realm. Please specify a valid user principal for the EJB to use.
    Getting weblogic deployment manager.
    Got weblogic deployment manager.
    Invoking Start Up operation.
    Start Up operation for application soa-infra on target soa_server1 RUNNING.
    Start Up operation for application soa-infra on target soa_server1 FAILED.
    weblogic.application.ModuleException: Exception preparing module: EJBModule(hw_services_wls_ejb.jar)
    Unable to deploy EJB: ASNSInteraction from hw_services_wls_ejb.jar:
    The run-as security principal, 'OracleSystemUser', chosen for the EJB 'ASNSInteraction(Application: soa-infra, EJBComponent: hw_services_wls_ejb.jar)' is not a valid user principal in the current security realm. Please specify a valid user principal for the EJB to use.
    I've checked both weblogic and OracleSystemUser users and their groups are (respectfully) Administrators and OracleSystemGroup.
    I've searched for an answer to this problem and found this other support article but couldn't resolve the issue.
    The weblogic server version is 10.3.2.0 and it's running on RedHat Linux.

    @Sri_Sonti
    In the Admin Console, I can see both users in the security realm with the following configs:
    weblogic:
    all atributes with the "value" column blank
    groups: Administrators
    OracleSystemUser
    all atributes with the "value" column blank
    groups: OracleSystemGroup
    Also I have not found the system-jazn-data.xml file you mentioned. In that folder there's only a readme.txt file.
    Best Regards,
    luismcs
    Enter Cookie as format:
    (ex: name=val;) separate with ';'
    OKCancel

  • SSRS (Report Builder 3.0) Showing all values for Multiple Line field with Append Changes

    I have a simple SharePoint list with a multiple line column that has append changes enabled. I am doing a report with Report Builder 3.0 and I want to show all values of the field the same way you achieve it through a DVWP using:<SharePoint:AppendOnlyHistory
    FieldName="Comments" runat="server"
    ControlMode="Display" ItemId="{@ID}"/>
    Any suggestions to show all the appended values?

    Hi,
    I am trying to involve someone familiar with this topic to further look at this issue.
    Regards,
    Forum Support
    Please remember to mark the replies as answers if they help and unmark them if they provide no help. If you have feedback for TechNet Subscriber Support, contact
    [email protected]
    Rebecca Tu
    TechNet Community Support

  • Showing all values for Multiple Line field with Append Changes

    I have a simple SharePoint list with a multiple line column that has append changes enabled. I am doing a report with Report Builder 3.0 and I want to show all values of the field the same way you achieve it through a DVWP using:<SharePoint:AppendOnlyHistory
    FieldName="Comments" runat="server"
    ControlMode="Display" ItemId="{@ID}"/>
    For reference, I'm trying to replicate this function, but on a report:
    http://sympmarc.com/2011/02/07/showing-all-versions-of-append-changes-to-existing-text-in-a-data-view-web-part-dvwp/ 
    Any suggestions to show all the appended values in a report?

    Hi Lewis75581,
    According to your description, you want to show the append changes history of a column in Reporting Services. Right?
    In Reporting Services, we don't have a feature to show the change history of a column. However, we can have workaround on SQL level. In SQL Server, we have tables: inserted table and deleted table which contains the recently inserted and deleted records.
    In this scenario, we can create a trigger in your database. Once you insert rows into the table, it will be triggered and get those inserted rows. Then insert those rows into another table. Now we can create one more dataset based on this table and display
    these inserted rows in our report. This might be the most effective workaround for your requirement. Please refer to a similar thread below:
    http://social.technet.microsoft.com/Forums/en-US/dacfb141-a976-489a-acca-789ba90e15de/ssrs-multiple-reports-with-different-parameteres-in-single-window?forum=sqlreportingservices
    Reference:
    Use the inserted and deleted Tables
    If you have any question, please feel free to ask.
    Best Regards,
    Simon Hou

  • How can I produce a title card with multiple lines of text?

    When I drag "title, multiple lines" to my timeline, the second line appears in a smaller font. When I type all my text on a single line, the title appears in a teeny-tiny font. I want to be able to produce four or five lines of text, all in a readable font. Help!

    2 solutions:
    Costs money and takes work:
    Look for a title plug-in on geethree.com. There are free ones out there too.
    OR.
    Works right now:
    Type your title into the 'scrolling block' title.
    Drop it in and let it render.
    Play it back and pause it when the text is in the middle (or where ever you want it). Choose 'create still clip' from the edit menu. And blamo! You've got multiple lines of the same sized text.
    This might take some experimenting to find what font works best. Some get a little jaggy in the rendering process and look bit-mapped a bit when changed into a still.
    Give it a shot!

  • Extract/Scan for numbers from multiple lines of strings

    Hi All,
    I would like to extract numbers (the data) obtained from a serial acquisition which will be shown in multiple line of strings:
    $#pressure 20
    !@temperature 100
    #voltage 1.2
    I want to extract 20,100 and 1.2 so that I can do further data manipulation. Should I use match regular expression ? I could not get a proper regular expression to extract the numbers.
    Thank you !
    Solved!
    Go to Solution.

    pokerprof wrote:
    Hi there! Yes your method works, but it would be better if we can keep all the data into an array separated to pressure, temperature and voltage since we are continuously acquiring data. 
    Can we put it into array ?
    Pressure   Temperature   Voltage
    20                    100          1.2
    21                    101           1.2
    Whose method? You don't say who you are referring to (and if you don't quote at least part of a message, we don't know unless you tell us).
    This is no time to keep your cards close to your chest, pokerprof .
    Cameron
    To err is human, but to really foul it up requires a computer.
    The optimist believes we are in the best of all possible worlds - the pessimist fears this is true.
    Profanity is the one language all programmers know best.
    An expert is someone who has made all the possible mistakes.
    To learn something about LabVIEW at no extra cost, work the online LabVIEW tutorial(s):
    LabVIEW Unit 1 - Getting Started
    Learn to Use LabVIEW with MyDAQ

  • Find and Replace multiple line PHP comment

    Greeting everyone!
    Hopefully this question is asked in the right place.
    I have about 300 php files that have multiple line PHP
    comment that start with /* and end with this */. I want to remove
    all the comments since I am trying to reduce the file size as much
    as possible. The comments are no longer needed and I have tried
    many different configureation in the dreamweaver find and replace,
    but for the life of me I cannot seem to get it to work. I even
    tried useing regular expressions, but the astrick * is a wild card
    the the code tags contain an astrick.
    Is it possible to do this in dreamweaver, or will I need to
    hand edit every page?
    Thank for help
    example

    I am not sure of the exact syntax but open the find replace
    function on a page and play with find syntax search feature from
    the drop down menu . If I am not mistaken you should be able to to
    search from the beginning of a comment tag to the end of one and
    grab whats in between. From the help file
    Use the Find And Replace dialog box to search for text or
    tags in a document, and to replace the found material with other
    text or tags.
    Select Edit > Find And Replace.
    In the Search pop‑up menu, select Specific Tag.
    Select a specific tag or [any tag] from the pop‑up menu
    next to the Search pop‑up menu, or type a tag name in the
    text box.
    (Optional.) Limit the search with one of the following tag
    modifiers:
    With Attribute Specifies an attribute that must be in the tag
    for it to match. You can specify a particular value for the
    attribute or select [any value].
    Without Attribute Selects an attribute that must not be in
    the tag for it to match. For example, select this option to search
    for all img tags with no alt attribute.
    Containing Specifies text or a tag that must be contained
    within the original tag for it to match. For example, in the code
    <b><font size="4">heading 1</font></b>, the
    font tag is contained within the b tag.
    Not Containing Specifies text or a tag that must not be
    contained within the original tag for it to match.
    Inside Tag Specifies a tag that the target tag must be
    contained in for it to match.
    Not Inside Tag Specifies a tag that the target tag must not
    be contained in for it to match.
    (Optional.) To limit the search further, click the Plus (+)
    button and repeat step 3.
    If you didn’t apply any tag modifiers in steps 3 and 4,
    then click the Minus (-) button to remove the tag modifiers
    pop‑up menu.
    If you want to perform an action when the tag is found (such
    as removing or replacing the tag), select the action from the
    Action pop‑up menu and, if applicable, specify any additional
    information necessary to perform the action.

  • How to Update multiple line Items in Sales order Interactive form

    Hi,
            I have created one online interactive form for sales order. In that I incorporated dynamic table logic .i.e. we can add row and delete row using buttons. Interactive form is working fine with one line item. But if I give multiple lines in table (line item) its creating sales order with single line item. So please help me how to pass multiple lines.
    Thanks & Regards,
    Krishna.

    Hi,
    Check out this link, this deals with the problem you are facing.
    http://www.sdn.sap.com/irj/scn/index?rid=/library/uuid/802f0ed1-a17a-2c10-7db4-d515a5b047ed
    Regards,
    Runal

  • How can I change the length of multiple lines at the same time?

    This just seems like it should be a no-brainer, but obviously for me it isn't.  I'm trying to change the length of multiple lines, that are at different angles, at the same time, in CS4.  Basically, I design the face of dials used for airplane instrument gauges (like RPM, Torque, etc), and they have gradiation marks (lines) located all around, similar what a clock looks like with the hour and minute gradiation marks (lines).  Is there a way to select all the lines, that I know are the same length, and change it to a different length, that's accurate to the 1/100th of an inch?  It would just be like selecting multiple lines that have all the same stroke, then using the stroke box to change the stroke weight from .025in to .030in.
    I've used the transform box to change the 'height' of a line before, but the line has to be at 90 degrees (straight up and down), and that won't work for the lines that are at, say, a 45 degree angle.
    I hope i'm explaining this in a way that someone will understand. If not, I can sure try to clarify more, or insert the picture so you could see what i'm talking about.
    Thanks for any help you can give!

    OK, after fiddling around with everyone's ideas, I think I finally got it. I knew there had to be something with proportions between W and H, but couldn't figure out the math, until Jacob answered with:
    "If each line must be strecthed from the inner/outer end, you may select each and use the Transform palette, choosing the right Reference Point, multiplying by the proportion in W or H (1.75/1.5), and Ctrl/Cmd clicking."
    Now, I basically did everything above, (but I couldn't figure out what you were talking about with the Ctrl Clicking thing), except after figuring out the right proportion (which ends up being so small you guys would die if I told you the number; the numbers I gave earlier were just an example and much larger than what i'm really working with) I just clicked the little chain next to the W and H boxes to constrain the proportions. I then put the new number (multiplied proportion by whatever was in W) in the W box. The line lengthened perfectly toward the center of the dial, keeping the correct angle!
    And Harron-Thanks for the link to Teri's, It is going to help with some things I do, but most of the dials I design don't have equal distances between each gradiation mark, and the blueprints I work off of usually have exactly what distances that the grad. marks are supposed to be. So, after selecting one of my grad marks that is already at it's correct place, I then use the rotate tool and Alt-Clicking the very center of the dial, I can then put in exactly what distance I want the next grad. mark to be at, I hit copy (instead of OK) and there will be a new grad. mark exactly the correct distance from my original. Then if I want to have the 3rd grad. mark I just hit Ctrl-D and it will copy another mark to the next position. I don't know if you necessarily wanted to know all that, but i thought i'd explain why I like doing it that way.
    A BIG thanks to everyone! I'm really a AI newbie and am the only one at my company that knows how to use it, so I don't have anyone close to ask stupid questions to. So I appreciate all your help!

  • To Record  J1IS BDC  For Multiple Line Items

    Hi,
      Iam trying to record BDC for J1IS transaction.
    while  recording  material document which contains more than  8 line items , Only 8 line items get saved and the rest of the items doesn't get saved ,
        But when I  do this manually then  all the line items get saved,
        Can anyone give the remedy for this Problem (to record J1IS for multiple line items).
      Thanks in Advance.
    Regards,
    S.Janani.

    Hi Janani / Leo
    The problem might be that the scroll down functionality after 8 line items is not recorded in your recording.
    In order to overcome the issue, you need to check OK__CODE whicle page down and add it in recording after Number of line items are greater than 8.
    Please check below link for details:
    http://scn.sap.com/thread/1106677
    http://scn.sap.com/thread/797827
    http://scn.sap.com/thread/2037271
    Best Regards,
    Sachin

  • Printing PDFs with Multiple lines enabled

    Hi, I need some help with Designer. I have no clue how to really use it, I've been playing with it for a week, but some things I can't figure out.
    I have a text field that fits about 1 line of text on it. I enabled multiple lines in the field, because people are going to be typing a lot. However, when I print it, only 1 of the lines shows up. Is there any way that I can fix the settings so that the box expands as the text is typed, and that if it can expand, the entire page shrinks to keep it to the same amount of page numbers instead of bumping everything down the page? If someone out there knows, please help!!!
    Thanks!!!

    Hi,
    Maybe this can help:
    1 - Save your form as a Dynamic Form
    2 - Place a subform with Flow content
    3 - Place a text box with multiple line in the sub form. Make it expand to fit (layout tab) and Data Format XHTML (binding tab)
    4 - Put the contents in the field
    5- Click outside the field and print it.
    regards

  • Uix table with multiple lines per row

    Hi,
    how can I design a table that has multiple lines for one row.
    It should look like this
    row1-cell1 row1-cell2
    row1-cell3 row1-cell4
    row2-cell1 row2-cell2
    row2-cell3 row2-cell4
    Thanks a lot.
    Christian

    Christian,
    I'll scribble down a quick example off the top of my head...
    <table data:tableData="${mydata}">
    <column>
    <stackLayout>
    <link text="cell1"/>
    <link text="cell3"/>
    </stackLayout>
    </column>
    <column>
    <stackLayout>
    <link text="cell2"/>
    <link text="cell4"/>
    </stackLayout>
    </column>
    </table>
    I recommend you just play around with UIX XML, and you'll find something that works.
    Hope this helps,
    Ryan

  • Text Field with multiple lines

    I am trying to create a text field in the selection screen where it can insert a text with multiple lines for instance those text fields which you can see online where you can key in text lines after lines.
    How do you do that in ABAP?

    Hi
    See any Std program code for CREATING long Text lines
    See any application document HEADER or ITEM text and copy that code
    first declare a field with some table field
    like
    PARAMETERS: p_text like Tline-tdname.
    then keep a button (for Long text) and in the program write a code such that when you press on that line it will take you to text ediotr
    using the CREATE_TEXT fun module
    copy it from a std program text..
    <b>Reward points for useful Answers</b>
    Regards
    Anji

Maybe you are looking for