ONS 15454 MRC 2.5G4

Hi All,
We are trying to install the optical multirate card (MRC 2.5Gig) on ONS 15454 and found the card comming up on standby state instead of active. The version running on the sonet box is 8.5.0 ...The MRC card port 1 is installed with the OC3 SFP's but cable not attached.
Any help would be appreciated .
Regards
Anantha Subramanian Natarajan

Hi, this is normal. Just go on and enable a SFP, called pluggable port module (PPM). After the first SFP is enabled, the state of the MRC card will change to working.
Cheers
Rene

Similar Messages

  • Timing over an ONS 15454 SONET link.

    Hello,
         Are there any provisioning restrictions on passing timing over a SONET link on the ONS 15454. Here is the senario; I have an OC-48 provisioned over Slot 4, port 1-1 on an MRC-12 card. On the Line provisioning tab, I am unable to set the ProvideSync check box. I need to use the link to time a distant end node. The far link is RX the STU SSM. The local Node is set for external timing with BITS 1 and 2 active and inservice w/PRS. Is there something I am missing?
    TIA,
    Steve

    Steve,
    The OC48 port is always providing timing information to the attached device in the S1 byte of the Line Overhead.
    The ProvidesSync box is not an indication of whether the port is providing timing.  Rather it is an indication that that port is being used as a timing source  (Line Timing).  If you go to Provisioning->Timing and select that slot/port as a Timing Reference the ProvidesSync box will be checked.
    I will upload a Word document with screen shots. It should help clear things up.

  • Upgrade ONS 15454 M12 TCC2P from 9.4.03 to 10.0.11

    Hello, 
    quick question.
    I have in my lab one M12 subrack with only-one TCC2P card and I try to prepare software upgrade in customer network.
    I read all procedures at: http://www.cisco.com/c/en/us/td/docs/optical/15000r/upgrade/guide/b-454a10-0-1-upgrade.html
    My troubles started at point where I can select node where the software must be downloaded. The window is empty.
    Target version is "ons15454.DWDM.Lite.K9.R10011.pkg".
    Any idea?
    Thanks
    kvapa

    Hi Emyrsonn,
    I hope this ONS 15454 upgrade tool can help you answering all your questions
    http://www.cisco.com/web/techdoc/optical/15000r/upgrade/guide/ons-upgrade.html
    It seems like you should be able to directly upgrade from 9.1.x to 9.2.2.
    Please let me know if you have any comments on that.
    Hope it helps!

  • DCN Case Study 3: ONS 15454 Linear Topology with DCN Connections at Both Ends Using OSPF

    Hi, I need advise regarding design of Network Connectivity - DCN Case Study 3: ONS 15454 Linear Topology with DCN Connections at Both Ends Using OSPF.
    Am I need area 100 and 200 on Router 1 and Router 2 or I can don't do that?
    Am 

  • ONS 15454 error message

    Hi Expert,
    I have a problem with ONS 15454 error message. My CTM server detected MINOR error message "Peer to Peer Slot Communication Failure". Affected object is SLOT-1 which is OPT_BST. The alarm ID is 200551. What caused this error appear and any workaround to solve this problem?. Your kind attention is much appreciated.

    Although the following alarm is not identical to the one you identified, this seems to indicate the a peer "communication failure" is hardware related.
    2.5.237 PEER-NORESPONSE
    Default Severity: Major (MJ), Non-Service-Affecting (NSA)
    Logical Object: EQPT
    The switch agent raises a Peer Card Not Responding alarm if either traffic card in a protection group does not receive a response to the peer status request message. PEER-NORESPONSE is a software failure and occurs at the task level, as opposed to a communication failure, which is a hardware failure between peer cards.
    Hope this helps....

  • ONS 15454 design question

    I have an ONS 15454 with 2 OC192 circuits that terminate into it. One goes to a downstream ONS and another to the upstream.
    I need to extend the existing ring to 2 more ONS devices, but I am not sure if it is going to work the way I want it to.
    Right now, each VTS24 circuit on the OC192 is associated with a POS interface on the ML1000 cards. So POS1 goes upstream, POS0 downstream (unprotected). The ML1000 is int turn trunked to a 3750 L3 switch that has the bridge groups and layer 3 addressing assigned. This is Ring0
    I need to extend this ring, so obviously I will need 2 additional OC192 cards, but do these new circuits need to be associated with new POS interfaces? In other words, will I need 2 additional ML1000 cards, and if so, how would I trunk to the switch? Am I going to get into some loopy topology here?
    I am new to this system, so any advice would be great.

    Hi Colin,
    so you want to add two more ONS devices in an existing ring.
    if you can provide a topology it will be helpful,
    if you just want to add two more ONS in existing ring, it will no cause any issues,
    we just have to take care of circuits and need to build them from TL1 in these new nodes.
    but please send topology to get an clear view.

  • Cisco ONS 15454 SDH

    Hi,
    i have 3 sites connecting together with SDH 15454 site A-B with STM-1 and from site B-C STM-16,i want to Aggregated hand-off E1's from Site A-C so site B will be trasparet site for this link.
    to be source of link on site A and Drop on site C.
    any help to achive this.
    there is already cricte between site B-C.

    You will need to verify that the cross-connect card in the ONS 15454 (sites B & C) have VC-12 grooming capabilities (XC-VXL and CX-VXC will support VC-12 grooming).
    The ONS is designed to groom lower rate signals to higher rate speed lines. Thus, you should be able to aggregate the E1s from the ISPs STM1 with the E1s from Site B and drop them at Site C.
    You will need to add an STM1 card(s) to Site B. Your ISP will need to provide the mapping structure of the STM1, so you can understand where the VC-12s, which contain the E1s, are located in the payload. You will then create circuits to map each E1 (the incoming VC-12s within VC3/VC4) from you ISPs STM1 at Site B, to the appropriate VC-12 on the outgoing STM16 line heading toward Site C. At Site C, you will need to map the VC-12s on the STM16 line to the appropriate port on an E1 line card.
    I hope this helps. Otherwise, you will need to have someone locally assist you in the explanation.
    Tom

  • ONS 15454 shows up as "unknown" after power outage

    We had a power outage that took down a ONS 15454 in a remote facility. Upon restoring power and powering-up the unit, it shows up in CTC as grey with "Uknown2" as the name.
    I had someone reseat the TCC card, but it still comes up as unknown.
    Has anyone seen this? Any suggestions (the device is hours from me)     

    Try and restart CTC session and clear CTC cache
    Can you ping the node
    Check to see if the node is in the OSPF routing table
    Can you access via CTC locally
    Is your CTC terminal directly connected or does it go via a firewall
    Probably resolved now how did you resolve it?

  • ONS 15454 Craft interface to a Cisco 2511 Terminal Server

    Does anybody have pinout of wiring ONS 15454 craft interface to a Cisco 2511 terminal server? I tried many combinations but nothing seem to work.
    2511 has octal cable with RJ-45 connector. I used an rj-45 coupler to connect a wire wrapped RJ-45 cable to craft interface.
    Thanks,

    Pin Field
    Contact
    Function
    Craft
    A1
    Receive
    A2
    Transmit
    A3
    Ground
    A4
    DTR

  • ONS 15454 problem turning up OC12

    Board.
    I am trying to turn up an OC12 (non-concatenated) that is muxed from a OC48. The OC48 terminates on an ONS 15454 on both sides. From there we run SM fiber to Cisco 12000 series onto an SM OC12/SMT4 Line card on both sides too.
    My settings for the ONS are as follows:
    Type=STS
    Size 12C
    Dir = 2way
    We see on one Cisco UP/DOWN, and on other Cisco Down/Down
    Does any on this forum have any tips at all?

    Which OC12 LC do you have on the 12000?
    CHOC12/STS3-IR-SC
    4OC12E/POS-IR-S
    4OC12X/POS-I-SC-B
    etc

  • ONS 15454 Version 8 Experience?

    I'd like to know the experiences of anyone who has upgraded to SW version 8.0 on ONS 15454 SONET nodes. I'm trying to decide whether to use the tried-and-true 7.2.2 load or go for 8.0, which doesn't have any maintenance revs out yet. I have to do something to get off version 4.6.1 and 5.0.5 soon.
    Thanks,
    Dave

    most that I log into are on 7.2.2. We have one of the largest 15454 networks in the US

  • ONS 15454 Chassis Document

    Hello All,
    I wanted to know if there is a document that will show how to put an ONS 15454 chassis together?  What each TCC, SMR, WXC card means and used for? What the DS, OSC, LINE, COM, EXP ports used for? Etc.
    If someone can point me in the right direction that would be great!
    Thanks!

    Well the product support pages show how to physically install y every componenet of the ONS equipment:
    http://www.cisco.com/en/US/products/hw/optical/ps2006/prod_installation_guides_list.html
    If you want an overview of the various cards' functions, please see the data sheets here:
    http://www.cisco.com/en/US/products/hw/optical/ps2006/products_data_sheets_list.html

  • ONS 15454 and AC/DC Converter for 220V

    I am looking for a AC/DC converter for a ONS15454 for a 220V input.
    The ONS 15454 datasheet indicate input current 22A maximum.
    The Cisco AC/DC Power Solution datasheet indicate for ONS 15454 a medium solution.
    And the same datasheet indicate the small solution is up to 32A for 220V.
    Then, can I use the small configuration for ONS at 220V?
    Anyone know that? Can you help me with that?
    Graciela

    What is the hardware configuration of your 15454 including chassis, fan and by slot?
    Using the hardware config, you can calcualte the expected amperage.
    http://www.cisco.com/en/US/partner/products/hw/optical/ps2006/products_tech_note09186a0080094ae4.shtml
    The general power requirement of 22A provides for any possible configuration. Actual configurations may be less. I have some 454s using as little as 9A in the lab.

  • ONS 15454 SDH with 2 ML cards connected to the same RPR

    I was wondering if I could connect 2 ML cards installed in the same ONS 15454 to the same RPR ring. Thanks!

    Bob,
    If you are wanting to tie the ML100 and the ML1000 into the same RPR Ring, then you have do do it with the POS interfaces.
    For Example:
    ML 100 POS 0   - North  Microwave
    ML 100 POS 1   - connect RPR to ML 1000 POS 0
    ML 1000 POS 1 - South Microwave
    North Microwave connects RPR to South Microwave
    This creates a single Loop or Ring
    It sounds like you are using your ML1000 as a Spur to another location.  In order to create an RPR ring, you must have the cards physically connected to each other in a continuous ring.
    Aaron Reed
    Carrier Escalation - Cisco Optical TAC

  • ONS 15454 Config Backup

    Does cisco have a tool to automate the database backup process for the ONS 15454?

    CTM - Cisco Transport Manager. It's Cisco's enterprise management tool for the optical products. It does a lot more than just backup the dbs - and has an accordingly non-trivial cost.
    See the info on the products and services pages at http://cisco.com/en/US/products/sw/opticsw/ps2204/index.html. The product data sheet (http://cisco.com/en/US/prod/collateral/netmgtsw/ps5730/ps2204/data_sheet_c78-518130.html) is a good start.
    Also see info under the support page at http://cisco.com/en/US/products/sw/opticsw/ps2204/tsd_products_support_series_home.html

Maybe you are looking for

  • How to generate dynamic header/footers?

    Hi, I'm still working at my bill-report :) I have to display the dealers logo+address as a "header" and legal disclaimers, customized bank details as a "footer". I guess, I can't do this with reports header and footer-sections? How can I solve the fo

  • Combine PDF Files Toolbar Button/Shortcut - Windows 7

    Hello is there a way to add a button to the windows folder toolbar (see pic below) or a keyboard shortcut to quickly combine pdf files without having to right click and select the option? I would love to save a step since I have to do this quite ofte

  • Error in Replication of SRM PO change to SUS

    Hello Everyone, We are using SRM 5.0 with extended classic scenario. We create the PO in SRM and then we transfer this PO to SUS. For the first time it is working fine but anytime you make a change to it the change does not transmit to the SUS portal

  • Zen micro media explo

    i got the new firmware for my zen micro 5 gb. since then zen micro media explorer wont work so i'v had to use the Creative MediaSource Organizer and i dont like it. Is there a way for me to update Zen Micro Media Explorer so i can organize my player

  • P67A-GD55, long reboot when overclocking

    Hi, I have the P67A-GD55 with an i5 2500k and the problem arises when I overclock: changing the vcore or the multiplier (with or without turbo, it doesn't matter) makes the system unable to reboot (in windows or save and reboot in the bios). It sits