Open Doc Function to pass parameters from Xcelsius to WEBI

Hi All,
I need to have a drill through functionality from xcelsius report to WebI report I am using the following open doc URL
http://BO ServerName/OpenDocument/opendoc/openDocument.jsp?
sType=wid&sRefresh=Y&sIDType=CUID&iDocID="Doc ID"&mode=full&lsSRegion=""&lsSDay=""&lsSPlant=""&lsSProduct%20Name=""
When I run the flash in Internet Explorer then the drill through webi report opens without any error for the 1st time
but when I try to reopen the report again with new set of parameters , the browser gets hanged
Also when I run the flash in Firefox , I get error while opening the Webi Report for the 1st time but when I try to open the report again it works fine.
Please let me know if anyone has faced similar issue before.
I am Using Xcelsius 2008 SP3 and BO XI 3.1
Thanks,
Shweta

Hi Shweta
If you place the URL un the browser directly does the report open and refresh ok?  Can you try altering the parameters of the URL, also directly in the browser?
Something else to check would be if the prompts in the WebI report can be optional, store the last value etc, and I wouldn't recommend having a prompt which has a space in the name such as you have (Product%20Name). Keep the prompts as simple as possible, and make sure that the 'equal to' and 'in list' operators are properly reflected in the URL. 
Regards
Charles

Similar Messages

  • Passing Parameters from Xcelsius to Webi

    Hi,
    I have done a dashboard in which I need to call the Webi report. But Iwas not able to call the webi report with dynamic prompt values passed from the xcelsius, following is the OpenDoc link which I used.....
    http://arbodv:8080/OpenDocument/opendoc/openDocument.jsp?iDocID=Ae8ejQvQW_BAmEz9rkJ1Zc4&sIDType=CUID&sType=wid&sRefresh=Y&nbPrompts=2&lsSPlant="&C5&"&lsSYear="&F5&"&sWindow=New
    I am passing Plant and Year as parameters where C5 is the destination cell for the Combo box containing Plant  and F5 is the destination cell for the Combo box containing Years.
    When I use this I am able to open up the Webi report, but it is coming up with message "No Data to retrieve" eventhough there is data.
    Plz help me in this..............
    Regards,
    ArunKG

    Hai
    Here is the Step by Step Procedure
    http://www.forumtopics.com/busobj/viewtopic.php?p=640660
    http://www.forumtopics.com/busobj/viewtopic.php?p=586186&sid=5246278a4142a5cdd3e4a121d7f07352
    http://boardreader.com/thread/How_to_pass_parameters_dynamically_from_6shlrX14yv8.html
    http://www.sdn.sap.com/irj/scn/go/portal/prtroot/docs/library/uuid/c0ecd052-ec2f-2c10-a89b-9be7c89e1f33?QuickLink=index&overridelayout=true
    http://www.forumtopics.com/busobj/viewtopic.php?p=731036&sid=ae288ad1b95a774d992aad0955660df4
    http://www.crystalreportsbook.com/Forum/forum_posts.asp?TID=3235

  • Passing parameters from portal to web dynpro

    Hi,
    I have a scenario in which the portal iviews are on one server and the web dynpro application is on another server,but i need the username details in the dynpro application,How can it be done.Would using webservics be helpful in this scenario?
    Regards,
    Bhavana

    Hi,
    Have look at this thread
    Re: Navigate from Web Dynpro app to portal page
    Regards,
    Saravanan K

  • Passing parameters from an URL to a WAD Web Template 7.0

    Hi guys, I need to pass parameters from an URL to a web template created with WAD 7.0. We need to open a template with certain filters starting from a link button located on an Xcelsius Dashboard. Our customer wants a web template to be opened with the filters defined within the Xcelsius
    The idea is to run the template with the filters defined in the URL. I know this was incredibly easy with WAD 3.x, but I didn't find any suitable solutions to use with WAD 7.0.
    What is the easiest way to do this with WAD 7.0?
    Thanks in advance and regards.
    Fabio Cristi

    Hi,
    It is possible in 7.0, but unfortunately it is a lot more complicated than i 3.x. There are quite a few examples here:
    http://help.sap.com/saphelp_nw70/helpdata/en/43/ef05462480025ae10000000a1553f7/content.htm
    I used it in a case where I wanted to embed a Web template in a BPS application and pass characteristic filters from the BPS application to the web template - similar to your requirements. Basically you need the following just to restrict one characteristic :o(
    &BI_COMMAND_1-BI_COMMAND_TYPE=SET_SELECTION_STATE
    &BI_COMMAND_1-TARGET_DATA_PROVIDER_REF_LIST-TARGET_DATA_PROVIDER_REF_1=DP_1
    &BI_COMMAND_1-CHARACTERISTICS_SELECTIONS-CHARACTERISTIC_SELECTIONS_1-SELECTIONS-SELECTION_1=SELECTION_INPUT_STRING
    &BI_COMMAND_1-CHARACTERISTICS_SELECTIONS-CHARACTERISTIC_SELECTIONS_1-SELECTIONS-SELECTION_1-SELECTION_INPUT_STRING=PDS06
    &BI_COMMAND_1-CHARACTERISTICS_SELECTIONS-CHARACTERISTIC_SELECTIONS_1-CHARACTERISTIC=0D_PH2
    I could only get it to work with one characteristic and I suspect, that the reason is that the URL simply gets to long (very quickly). You have to repeat the above for every characterstic you want to use :o(
    Hth,
    Jacob

  • Pass parameters from JSP Dyn Page to WDJ Application

    Hi,
    I am trying to pass parameters from my JSPDyn Page to WDJ Application.
    I am using NWDS 7.1 EHP1
    My code is :
    function to_WEBDYNHK()
          EPCM.relaxDocumentDomain();
          EPCM.doNavigate
        ('ROLES://pcd:portal_content/Himanshu.Himanshu/TestDynUIApp?DynamicParameter="hkparam%3Dqwertyuio"');
    This method is being called on click of a button.
    hkparam is the parameter in question.
    The JSPDyn page is an iView and the WDJ application is a page and both have been assigned to a role.
    In the properties of the WDJ Page, I have removed DymanicParameter from "Do not Forward These Parameters To Web Dynpro" property.
    However I am getting null as the value of hkparam in my WDJ application.
    The code used is :
    IWDRequest request = WDProtocolAdapter.getProtocolAdapter().getRequestObject();
           String param1= request.getParameter("hkparam");
    What seems to be missing here.
    Please help.
    I went through the documentation on SDN but it does not seem to help.
    TIA,
    Himanshu

    Hi Himanshu,
    Try this code.
    EPCM.doNavigate("ROLES:portal_content/Himanshu.Himanshu/TestDynUIApp?hkparam=Dmypass1123")
    if the parameter is hkparam and the value to be passed is Dmypass1123. You need not change any design time property of the WD page, and WDProtocolAdapter should retrive the parameter.
    Regards,
    Vishweshwara P.K.M.

  • Passing Parameters from One Screen to Another Screen

    Hi All,
    I need to Pass Parameters from one Module Pool Screen to Another Screen.
    I have two Parameters in First screen. I don't want to use <b>Export and Import</b>
    The first screen record should sit in the Second Screen as it is.
    Please suggest me.
    Thanks and Regards,
    Prabhakar Dharmala

    An Idea,
    Create a function group, in that define global variables. Then create two function module. Pass variable from one function module and get in the another one.
    Hope this will help you to solve. If you need further help I will create and sent you a test code.
    Darshan.
    <i><b>Pl. Reward points to the helpful answer, it motivates us to answer more </b></i>

  • Passing parameters from dynpro to a web dynpro

    Hi all,
    we have following scenario: a user starts a web dynpro, fills in the week and push a button. By this, an interactive form is created, with the users personal ID and the week, so the user can maintain his worked times.
    Now our problem is that we want to go into that interactive form skipping the web dynpro, i.e. we don't know how to pass parameters from a dynpro to a web dynpro.
    Do someone have a clue how we can do that? I would highly appreciate any help.
    Many thanks in advance
    Regards
    Anna

    hi anna
    please check the following links it is explains simple webdynpro java examples which is using interactive forms.
    http://help.sap.com/saphelp_nw04s/helpdata/en/dc/f1783fe3263042e10000000a114084/frameset.htm
    https://www.sdn.sap.com/irj/scn/go/portal/prtroot/docs/library/uuid/2b6db1c4-0801-0010-faa5-ff4b4df55b45
    https://www.sdn.sap.com/irj/scn/go/portal/prtroot/docs/library/uuid/b0d60ac9-3f59-2a10-4a86-a612d41c24e4
    Thanks and Regards
    shanto aloor

  • Passing parameters from portlet reports to portlet forms

    Hi,
    I'm tring to pass parameters between a Report displayed as a portlet in a page ( page 1) and a form displayed in other page ( page 2).
    The problem is i can't do this.
    I only can pass parameters from a report ( running as normal or in a portlet displayed in a page) to a form running "normal" by using application links. Can i do this between a report that show's me every employees of scott.emp table. Then when i click on each employee, it open's me another page with the portlet form of the specified employee.
    I'm not sure i made myself clear. Please send me some feedback.
    Pedro

    I have the same problem. Please let me know if this could be done.
    In particular my form is a type of "Form on Table/View."
    Thanks
    Henry

  • How to hardcode username/pwd in the open doc function.

    How to hardcode username/pwd in the open doc function.
    can you please provide the complete opendoc function

    hi,
    Using SDK, logon token can be passed along with OpenDoc URL.
    Sample code is as follows:
    String openDocumentToken() throws SDKException, Unsup
    portedEncodingException
    IEnterpriseSession sess = CrystalEnterprise.getSessionMgr().logon ("username", "password", "<cms>:</port>",
    "secEnterprise");
    String token = sess.getLogonTokenMgr().createLogonToken("",120,100);
    String tokenEncode = URLEncoder.encode(token, "UTF-8");
    return ("http://<server>:<port>/OpenDocument/opendoc/openDocument.jsp?iDocID=Aa6GrrM79cRAmaOSMGoadKI&sID
    Type=CUID&token=" + tokenEncode);
    Regards,
    Vamsee

  • How can I pass parameters from one process flow to another process flow?

    How can I pass parameters from one process flow to another process flow (sub process) in warehouse builder? let me know the steps I have to do in warehouse builder.
    Thanks in advance,
    Kishan

    Hi Kishan,
    Please post this question to the Warehouse Builder forum:
    Warehouse Builder
    Thanks, Mark

  • Passing parameters from a browser URL to Flash

    Flash CS3, AS3
    Is there any way to pass parameters from the URL line in a
    web browser to actionscript?
    ie. so if you had something like the following URL link in
    the browser...
    http://www.somedomain.com/someswf.swf?var1=10&var2=false
    ...it would pass var1 and var2 to someswf.swf.
    (Hypothetically, of course - I'm unsure as to the necessary syntax)
    Is this possible? Or would I need some intermediary software?
    Thanks
    Rick

    i answered a very similar forum query a few days ago
    here
    You need to look into loaderInfo.parameters.

  • Automatically Pass Parameters From Crystal To SAP B1

    So, I've searched extensively, and haven't been able to find an answer to my unique issue.
    This question pertains to linking a Crystal Report by parameter values to the OWOR table in SAP B1, and automatically passing those parameter values from the active record in SAP. Several other tables are used in sql joins, but the report is generated from an OWOR production order. I should start by stating that the report works great when manually populating the parameter fields when SAP calls for them.
    Overview:
    I've written a report in Crystal that contains several sub reports, some of which are looking to the DocEntry field as the parameter (DocKey@) and others that do not look to the DocEntry field at all - but rather use another field on the form to pull up information that spans more than just that one production order. I've chosen to upload as a layout in SAP (as that is all I've worked with up to this point, and it seems it needs to be to automate from a production order); but as I continue to research, it appears DocKey@ is mandatory when uploading as a layout, and in order to view the report from the actively selected production order, it must be a layout. Does that mean the parameter is required in all sub reports? Is it required in any sub report?
    I have two main issues that I need to hurdle for this report to work how I would like it to:
    1. Three of the eight Commands (one main command and seven sub-report commands) use the DocKey@ as the parameter to pass from SAP back to Crystal. The main report command, as well as four of the sub reports/commands are looking to another field in the OWOR record - which happens to be a re-seller defined field (UDF). For all intensive purposes, let's call this field BatchID. I'm assuming the sub report commands run in succession, one after the next. The reason I need to use BatchID as the parameter to pull from the record, rather than DocEntry, is there are other records that contain the same BatchID, and I want all of the info pertaining to that BatchID to populate on the report.
    Q1: The first command containing DocKey@ is automatically populated by SAP, and the user does not have to key that one in. However, the next two DocKey@ parameters do not automatically populate, and the user is asked for those values. How can I fix this?
    Q2: How can I automate the passing of BatchID so the user does not have to fill it in 5 times when they wish to preview the report(layout)? Can I link ObjectID@ to any field in OWOR? Is there any other way like creating a stored procedure or something , to automate the passing of that variable from the SAP active record to the crystal report - so the user doesn't have to key it in several times just to pull up the report?
    Thank you so much for even reading, let alone helping me with this issue!!
    Cheers,
    Nick

              Hi
              I had the same problem. Take a look at this newsgroup article on the businessobjects
              website :
              http://support.businessobjects.com/library/kbase/articles/c2015264.asp
              Grieg
              "Rada Pickens" <[email protected]> wrote:
              >
              >Hi,
              >
              >I'm getting the same error message, I was wondering if you fixed the
              >problem.
              > I'm stumped, can you help?
              >
              >Rada
              >
              >
              >"JAI" <[email protected]> wrote:
              >>
              >>I am passing parameters, from the JSP page to Crystal Report, i took
              >>the code from
              >>the below mentioned url, i dont know, it is something wrong with the
              >>jsp page
              >>or crystal report.
              >>i have created parameter field in crystal report to receive the value
              >>from the
              >>jsp page.
              >>If u r not clear with the error, please reply to me.
              >>
              >>i took the code from the below mentioned page
              >>
              >>reference page:
              >>----------------------
              >>http://dev2dev.bea.com/trainingevents/webinars/012804_faq.jsp
              >>parameterFieldsViewReport.jsp
              >>
              >>
              >>error displaying in the jsp page
              >>-----------------------------------
              >>com.crystaldecisions.report.web.viewer.CrystalReportViewer
              >>Some parameters are missing values
              >
              

  • Passing parameters from shell script to OWB process flow

    Hi all,
    I am running OWB process flow (using the template script provided by oracle) and i want to pass two date parameters as shown below:
    sqlplus -s $SQL_USER/$SQL_PWD@$ORACLE_SID @$HOME_DIR/src/vmc_oem_exec_script.sql OWB_OWNER VMC_POST_DW_PF_LOC_SIT PROCESS VMC_NM1_PORT_MAIN "," "P_DATE_FROM=$DATE_FROM,P_DATE_TO=$DATE_TO"
    How do i catch those values in process flow and pass those to mappings in Process flow?
    Do i need to create PF variables with same names or any name will do?
    Thanks in advance

    This document is explaining how to pass data between activities in process flow.
    I am passing parameters from a shell script.
    Any ideas,how to pass parameters from shell script and then initialize the process flow variables based on those values and then pass them further to mappings.
    Thanks

  • Pass parameters from hbj link

    Hi,
        I want to pass parameters from hbj link to the component where the event method is going to be called. And also when I click the event how it is going to redirect other jsp.
    Regards,
    Suresh.B

    Hello Reinuka,
    It is possible to send parameter to Web Dynpro iview.
    In the iview application parameters add Param1 =.
    Place this code wherever  you want to call that iview.
    WDPortalNavigation.navigateAbsolute("ROLES:"+iview,WDPortalNavigationMode.SHOW_INPLACE,(String) null, (String) null, WDPortalNavigationHistoryMode.NO_DUPLICATIONS,(String) null,(String) null,"Param1 = ");
    "ROLES:"+iview=Iview Path
    "Param=Paramvalue"=Parameter and its value
    Youcan receive the value as
    String parmvalue=WDWebContextAdapter.getWebContextAdapter().getRequestParameter("Param");
    Regards,
    Sridhar

  • Passing parameters from one form to another

    Hi,
    I'm trying to pass parameters from 1 form to another. I would be able to call the form, but the parameters are not passed to the calling form. I do not know what's the problem. Basically, the 2nd form shows up with blank values in all the fields. Below is my code. Anybody expert in this, pl. help.
    By the way my 1st form is based on PROCEDURE.
    declare
    s_requestor           number(10);
    s_customer_impact      varchar2(4000);
    s_creation_date      date;
    l_url                varchar2(4000);
    blk               varchar2(10) := 'DEFAULT';
    begin
    p_session.set_value(
    p_block_name => blk,
    p_attribute_name => 'A_P_REQUESTOR',
    p_value => 88888);
    s_requestor := p_session.get_value_as_number
    (p_block_name => blk,
    p_attribute_name => 'A_P_REQUESTOR');
    s_customer_impact := p_session.get_value_as_varchar2
    (p_block_name => blk,
    p_attribute_name => 'A_P_CUSTOMER_IMPACT');
    s_creation_date := p_session.get_value_as_date
    (p_block_name => blk,
    p_attribute_name => 'A_P_CREATION_DATE');
    l_url:=('/pls/portal/PORTAL.wwa_app_module.link?
    p_arg_names=_moduleid&p_arg_values=1794837934&
    p_arg_names=_show_header&p_arg_values=YES&
    p_arg_names=REQUESTOR&p_arg_values='||s_requestor||'&
    p_arg_names=CREATION_DATE&p_arg_values='||s_creation_date||'&
    p_arg_names=CUSTOMER_IMPACT&p_arg_values='||s_customer_impact);
    PORTAL.wwa_app_module.set_target(l_url);
    end;

    the way to call one form from another and pass values for parameters from the procedure is like this:
    PORTAL.wwa_app_module.link (
    p_arg_names => PORTAL.wwv_standard_util.string_to_table2('_moduleid:_show_header:REQUESTOR:CREATION_DATE'),
    p_arg_values => PORTAL.wwv_standard_util.string_to_table2('1191314879:YES:'||s_requestor||':'||s_creation_date));
    and so on.
    Hope it works for you

Maybe you are looking for

  • How can I move my iPhoto Library from my MacBook Pro to my iMac or hard drive??

    How can I move my iPhoto Library from my MacBook Pro to my iMac or to my external hard drive? 'Help' is not helping!!

  • Xcelsius 2008 SP3 + SAP BW Integration

    Hi All, We are at BO Enterprise Server Ver 3.1 SP2 Fix Patch 2.5 on OS: AIX 5.3, Xcelsius 2008 SP3.1 and BW 7.0 Xcelsius is unable to connect to BW. Msg we receive is..... "The system you are currently connected to is not BW 7.02 or newer. Please dis

  • ISE Configuration in Distributed Environment

                      Hi All, I have quick questions about  ISE deployment in Distributed environment, as i have purchased 2 X Cisco ise 3395 - For Data Center and 3 X Cisco ISE 3355 for remote location with 3500 Base licences and 500 Advance licences. i

  • User exits For Vl01n

    i want to block the delivery aftercycle closing in VL01N for shipping point 1103 selection date not more that 3 days after closing. For Order Type Is 2873 1901 2902 A popup Message Will Apper If Delivery Is After  Day's . So How Can I Solve This Issu

  • Acrobat Designer -Show/Hide/Delete Pages

    I have a PDF that is built in Designer 7.0.41126, it has 3 static data capture pages and 6 dynamic pages that are set to hidden at the begining of the process. Once the user captures the data they click a generate button and the script makes the page