Open relay test results
Hi all. I'm a new Ironport user, having just started working for a company that had a Spam and Virus Blocker already up and running.
We've been put on some blacklists for acting as an open relay. Apparently my predecessor had already done much of the work involved in fixing this problem, but we're still on blacklists. I'm not sure when the last time we really were an open relay was; it could have been before the Ironport was ever installed. I want to clear our name, but before I start requesting removals, I want to be 100% sure that the problem is addressed.
I've run some online open relay tests, and most report that we are not an open relay, but when I tried http://www.rbl.jp/svcheck.php , 5 of their 19 tests came back as "accepted".
I searched the Ironport knowledge base and found that our settings already match the recommendation -- our RAT is set to reject "all other recipients".
Here are the recipients from the tests that came back as "accepted":
>>> RCPT TO: <rlytest%[email protected]>
>>> RCPT TO: <"[email protected]"@server01.mycompany.com>
>>> RCPT TO: <h.rbl.jp![email protected]>
>>> RCPT TO: <"rlytest%h.rbl.jp"@mycompany.com>
>>> RCPT TO: <"[email protected]"@mycompany.com>
"server01" is the name of our Exchange server. Our firewall is set to forward port 25 to the Ironport.
Some of the tests suggested that even an "accepted" message was not a sure sign of being an open relay, and that the mail server might accept it and then silently discard it anyway. Is this something I need to fix, or is it already handled by the Ironport? How can I tell for sure? I've considered telnet'ing in from my home PC and reproducing the commands shown on that site using a real email address of my own, but I'm not really confident in this procedure, or in the procedure of "properly" malforming email addresses. Any advice?
Can anyone recommend further steps for me to take to be sure we are not operating an open relay?
Thank you for the quick reply, Steven.
It seems as though my Ironport does not have the "findevent" command. When I tried it I got an "unknown command: findevent" message, and the "help" message does not list findevent. Are you sure that command exists in the Spam and Virus Blocker, and not just other Ironport models?
I notice that there are two upgrades available to download for my Ironport, so maybe it's just that my current version is too old. I'm not sure I'm daring enough to install the upgrades during business hours, so I'll probably do that on the weekend.
Thanks again.
Similar Messages
-
I had just recently changed from a commercial mail server to using postfix/cyrus as supplied with 10.4.4 server. Set up went well though did get bit by having some mail come in before any users had login, there by causing some accounts to use the default mail store, when I wanted them using specific mail stores associated with their virtual domains.
Anyway got that all sorted out, with the help of messages other had posted here about similar problems.
I've also ran the mail server though a few open relay checks with no problems found, and have been going through the smtp mail logs every day for the last week and it looks like everything is buttoned down tight. But in doing so, it brings me to my question.
As far as I can tell, all of the open relay tests available are from 1999 - 2003. Seems these are going to be outdated and that those wanting to co-opt mail servers to use for spamming have probably found new methods.
So, any good relay test suggestions from anyone?
Tom N.Better late than never I guess...
Create an account at http://www.abuse.net/relay.html by sending an email message to "[email protected]".
regards
/rune -
How to close OPEN RELAY on Exchange 2010 EDGE server
How to close open relay on it?
Server passed OPEN relay test and we would like to avoid spammers attackin us.with best regards
bostjancGet-ReceiveConnector | Get-ADPermission | where {($_.ExtendedRights -like "*SMTP-Accept-Any-Recipient*")} | where {$_.User -like '*anonymous*'} | ft identity,user,extendedrights
Identity User
ExtendedRights
EXCHANGE-EDGE\Default internal receive co... NT AUTHORITY\ANONYMOUS LOGON {ms-Exch-SMTP-Accept-Any-Recipient}
Recreated RECIEVE CONNECTOR on EDGE solved it.
bostjanc -
RT
Here is an example of a sequence opening an excel document and creating a table. You have to slightly modify it, to save Serialnumber, high limit, test result etc. But this will be a good start.
Hope this helps
SijinK
National Instruments
Attachments:
Write_Table_to_XL_and_Create_Chart.zip 9 KB -
Test data corrupted issue while re-opening the Test in PTF8.53
Hi,
While re-opening the test case in PTF8.53,there is a pop up message displaying test data is corrupted.
Ran successfully yesterday,trying to reopen however getting this issue.
Any solution to retreive it back?Actually....iam opening the form from windows xp.Means what? Are u opening in the browser or in the Forms Builder?
----in the browser
when i create a new form in windows xp using developer suite (i have installed developer suite) i am able to connect the database. i checked the tnsping in server its working.....
This means developer suite has been configured for database.---i configured the developer suite(172.16.7.123) to 9idb(172.16.7.2)
but i am not able to open the form.What error are u getting when u open the form?
---when i open the form in the browser (http://appsworld.ncc.com:7778/forms/frmservlet?config=test)
its asking me the username,password,database.
i gave username=ncc password=nccpwd database=test
In the db server's tnsnames.ora...i have given the db details under test.
if i do "tnsping test" the result is ok. but when i open the form in the browser im getting the ora-12514 error after giving the above said details of username.
But....when i give the username,password and database of infrastructure i.e.,
username=system password=oradba database=orcl then the form is opening in the browser. -
Has to type each character twice while supplying command in Open VISA test panel
has a set of commands to work witha system connected to the MS windows PC. when I trype the commands in Hyperterminal (with/without ) they are yielding the expected results.
in LabVIEW, to get the expected results I MUST has to type 'each character' in the command Twice(except blank space) in the Open VISA test panel (viWrite/viRead). If I give the command is given the usual way(with each character typed only once), the result always is 'illegal command'.....the same works fine in the Hyperterminal.What confused Ashwin is that you said "In LabVIEW". OK, so you're using the MAX test panel. There's one thing that's not clear. You said "when I trype the commands in Hyperterminal (with/without )". With/without what? How is your Hyperterminal session configured? Have you tried something like PortMon to see what's actually being sent from the serial port driver?
-
How to fill pre-defined tables in Word 2003 with test results?
Hi All,
I have a simple test board , where i measure different DC levels, with a simple Vi that saves the test results in to a Text file.
These results in text file, were manually typed in to a test report , which is a Word document with tables, but i have now created a macro in word 2003 that can take the results from text file and added to the specific rows and columns in my word test report file.
The big questions is how can i get Labview to,after it has measured the DC levels, write the test results to the specific tables , rows and columns, in the Word document without deleting all?
The attached picture illustrates one tables , and the yellow cells showing the cells that need to be filled in with test results.
Labview vers: 2009
Solved!
Go to Solution.
Attachments:
Template.jpg 37 KBHi!
I'm a Test Engineer for electronics and I create alot of automated tests with LabVIEW. Many of our customers want testsresults in a fancy and easy-to-read report. I did not have the MS Office Report Generation tool. So I did some research in the Excel Board and came a cross a link to a free open Excel toolkit ( Link ). The toolkit looks like this in LabVIEW:
As you can see, you have many tools to get the job done. I'm talking about reading, writing and formatting Excel. The toolkit uses activeX. If you give me a few minutes I'll create an example for you.
What I do when I create a report:
Step 1. Create a template with all your formatting, macros, images and colors. Name the file for example "template.xlsx" (or .xls if you use an older office version).
Step 2. In your program, copy the file to the desired location and give it a proper name.
Step 3. Aquire some data and write it to the file you copied and renamed.
For my latest project I created a fully-automated testprogram for testing a electric product. After each test a report is generated based on the procedure above. After testing all the products I have for example 300 reports. I then created a program that reads all the reports and creates a summary report that contains statistics for all the tested products. In my program I can also print the reports or the summary report and deliver to our customer. All this takes just a few seconds and adds extra quality to the products we sell to our customer.
Regards,
Even
Certified LabVIEW Associate Developer
Automated Test Developer
Topro AS
Norway -
Trying to replace an open relay for servers/applications on exchange 2013 so I can retire exchange 2007, but I get the unable to relay error. I’ve created the new frontend connector on CAS server with its own IP/DNS entries, scoped it and put security
identical to the working connector on 2007. Also, I ran the obligatory:
Get-ReceiveConnector "exchange1\relay2" | Add-ADPermission -User "NT AUTHORITY\ANONYMOUS LOGON" -ExtendedRights "Ms-Exch-SMTP-Accept-Any-Recipient"
Used ADSIedit to verify it has the exact same permissions as the working relay connector in old exchange.
Exchange 2013 I think, is not using the connector. When I telnet to relay.domain.com (exchange 2007), I get 250 relay.domain.com Hello [ip] as expected. When I telnet to relay2.domain.com (exchange 2013), I get 250 exchange1.domain.com Hello [ip] whereas
I would expect to get 250 relay2.domain.com. If I attempt to send, I get unable to relay and logs show connection attempts using Exchange1\Default Front end connector.
What did I miss?After some more testing, I think I may know what's going on, but not why. I removed all the IPs from the remote range and added just one IP address and restarted the transport service. I can still open a telent session from a server that is not in
the list.
From the How Does Exchange 2013 Know which recieve connector to use? section of http://exchangeserverpro.com/exchange-2013-configure-smtp-relay-connector/, he states the following:
Simply put, receive connector selection is on a “most specific match wins” basis. The connector with remote network settings that most closely match the IP of the connecting server/device will
be the one that handles the connection.
This is not happening in my case. Even though my custom relay connector is a closer match, connections are going to the default frontend connector. -
Hi,
Does anyone know how to disable open relay in ocs 904?
I've tried setting:
relay allowed = false (smtp_in parameter)
But it still allows the relaying of mails. The only way i can stop it is turning anti spam on, and that results in mails not getting sent or received.Paul,
I had to eventually set relay allowed to false, aswell. For some reason i could no longer send mails via the webclient, sure outlook etc worked. The smtp_in log contained the following:
(msgid ESSM-503)(mtext spam check failed for recipient: SMTP Authentication not done;relay not allowed for rcpt:[email protected]
(mtext S: 550 Spam check failed for recipient's address:
[email protected])
The following message prompted me to set relay allowed to false - I would have thought the web client passed the authentication check. -
LSO200 test result not populated
Hi there,
We run LSO on 4.7x200 with J2EE620. The problem we got is that when a user doing a test, the test result was not recorded and in the table HRP1001 the user name is the ID used in LSM config under /../lsm/mediator/config.
Infotype 5008 is configured correctly.
Any Idea?
Thanks!
JasonHi, test the following statement in command line:
SQL>VAR ordercursor REFCURSOR;
SQL>EXECUTE GETORDERsBYCATALOGUECODE('001',:ordercursor);
SQL>print :ordercursor;
I+n your code, the error is OPEN ORDERCURSOR, the ORDERCURSOR cursor is open by default.+
Your correct code is:
declare
ordercursor SYS_REFCURSOR;
orderid NUMBER;
numberordered NUMBER;
costcharged BINARY_DOUBLE;
begin
GETORDERsBYCATALOGUECODE('001',ordercursor);
DBMS_OUTPUT.ENABLE(20000);
DBMS_OUTPUT.PUT_LINE('Order Number, Number Ordered, Cost Charged');
LOOP
FETCH ordercursor INTO orderid, numberordered, costcharged;
exit when ordercursor%notfound;
DBMS_OUTPUT.PUT_LINE(orderid || ', ' || numberordered || ', ' || costcharged);
END LOOP;
CLOSE ordercursor;
end;
Roberto.
Edited by: user584812 on Dec 23, 2008 3:47 PM -
Load Test Results - time series request data for by URL in VS2013
I am trying to figure out how to export and then analyze the results of a load test, but after the test is over it seems I cannot find the data for each individual request by url. This data shows during the load test itself, but after it is over it seems
as if that data is no longer accessible and all I can find are totals. The data that I want is under the "Page response time" graph on the graphs window during the test. I know this is not the response time for every single request and is probably
averaged, but that would suffice for the calculations I want to make.
I have looked in the database on my local machine (LoadTest2010, where all of the summary data is stored) and I cannot find the data I'm looking for.
My goal is to plot (probably in excel) each request url against the user load and analyze the slope of the response time averages to determine which requests scale the worst (and best). During the load test I can see this data and get a visual idea but when
it ends I cannot seem to find it to export.
A) Can this data be exported from within visual studio? Is there a setting required to make VS persist this data to the database? I have, from under Run Settings, the "Results" section "Timing Details Storage" set to "All individual
details" and the Storage Type set to "Database".
B) If this data isn't available from within VS, is it in any of the tables in the LoadTest2010 database where all of the summary data is stored?
Thanks
LukeHi Luke,
Since the load test is used to
simulate many users accessing a server at the same time, it is mainly verify a wev server load stress.
As you said that you want to find the data
for each individual request by url, I know that generally we can analyze the url request from the Summary like the following screen shot.
>>I
have looked in the database on my local machine (LoadTest2010, where all of the summary data is stored) and I cannot find the data I'm looking for.
I suggest you can try to add the
SQL Tracing Connect String in the Run Setting properties to trace the data.
Reference:
https://social.msdn.microsoft.com/Forums/en-US/74ff1c3e-cdc5-403a-b82f-66fbd36b1cc2/sql-server-tracing-in-visual-studio-load-test?forum=vstest
In addition, you can try to create an excel to analyze the load test result, for more information:
http://msdn.microsoft.com/en-us/library/dd997707.aspx
Hope it help you!
Best Regards,
We are trying to better understand customer views on social support experience, so your participation in this interview project would be greatly appreciated if you have time. Thanks for helping make community forums a great place.
Click
HERE to participate the survey. -
SQL Developer crashing when opening or testing a connection
SQL Developer closes abruptly when opening or testing a connection.
Here's what I do.
Open SQL Developer.
Create a connection:
Connection Name: [some string]
Username: [username]
Password: [password]
Save password: checked
Oracle tab:
Connection type: TNS
Connect Identifier: somedatabasename
Then I click on "Test" and the application immediately quits. No error messages. The app does the same thing if I save the connection and try to expand its node on the list of connections.
Mind you, if I use sqlplus like so:
[username]/[password]@somedatabasename
It connects just fine.
I captured the output from the command console after SQL Developer crashed:
Microsoft Windows [Version 6.1.7601]
Copyright (c) 2009 Microsoft Corporation. All rights reserved.
C:\Oracle\product\sqldeveloper\sqldeveloper\bin>sqldeveloper
_execv() failed, err=2Registered TimesTen
# A fatal error has been detected by the Java Runtime Environment:
# EXCEPTION_ACCESS_VIOLATION (0xc0000005) at pc=0x000000006d9f97c5, pid=5480, t
id=5840
# JRE version: 6.0_43-b01
# Java VM: Java HotSpot(TM) 64-Bit Server VM (20.14-b01 mixed mode windows-amd64
compressed oops)
# Problematic frame:
# V [jvm.dll+0x1397c5]
# An error report file with more information is saved as:
# C:\Oracle\product\sqldeveloper\sqldeveloper\bin\hs_err_pid5480.log
# If you would like to submit a bug report, please visit:
# http://java.sun.com/webapps/bugreport/crash.jsp
I am using:
sqldeveloper 3.2.20.09.87 (64-bit)
Java 1.6.0_43 (64-bit)
Windows 7 Enterprise SP1 (64-bit)
ODAC 11.2.0.3.20 x64
Please help!
Edited by: 993662 on Mar 13, 2013 9:10 AM@Jim:
Thanks for your suggestion. After several hours of experimenting, I've managed to fix my problem by copying the ojdbc6.jar from my ODAC installation and replacing the one in [sqldeveloper root]\jdbc\lib
To whomever has a similar issue: See my original post for what software I was using and their version numbers.
Edited by: FrostyZoob on Mar 14, 2013 8:11 AM -
Outlook 2013 crashes when opening Calendar search result
I have a user who uses her Outlook 2013 calendar extensively, mainly to note for herself when she has spoken to a customer, and creating appointments for when she needs to speak to them again. (This is outside of our policy to note the contact in
MS CRM.) She can have scores of such Calendar items each day.
When seraching for these appointments in her Calendar, she gets the list of results, but Oulook crashes when she tries to open any of them. Sometimes Outlook restarts on its own, sometimes she must relaunch it herself.
Related threads reference a wwlib.dll error, but she is not getting that. It is Outlook.exe itself that is crashing. There are other threads that reference other open windows, or items containing webpages or tables, but these do not apply to her, either.
Event Data (two related entries) contain the following:
OUTLOOK.EXE
15.0.4551.1004
5253ad6f
c0000005
00025b09
19cc
01cef2a610938033
C:\Program Files\Microsoft Office\Office15\OUTLOOK.EXE
C:\Program Files\Microsoft Office\Office15\OUTLOOK.EXE
77f5e493-5e9b-11e3-9ef4-00219b4a7172
And:
3915849571
1
APPCRASH
Not available
0
OUTLOOK.EXE
15.0.4511.1004
5253ad6f
OUTLOOK.EXE
15.0.4551.1004
5253ad6f
c0000005
00025b09
C:\Users\[username]\AppData\Local\Temp\163947659.cvr C:\User\[username]\AppData\Local\Temp\CVR780F.tmp.cvr
C:\Users\[username]\AppData\Local\Temp\WERA546.tmp.WERInternalMetadata.xml
C:\Users\[username]\AppData\Local\Microsoft\Windows\WER\ReportArchive\AppCrash_OUTLOOK.EXE_2e80497b46642ed3f64262bb26bbba2f6ecc_02d1bdd5
0
77f5e493-5e9b-11e3-9ef4-00219b4a7172
0
On answers.microsoft.com, Girish M (Support Engineer who eventally directed me here), asked me to run Scanpst.exe. I would paste the results here, but this window does not seem to allow pasting. A summary description of what it found on her .ost file (no
.pst in use) is basically this:
**Beginning NDB recovery
**Attempting to open database
**Attempting to validate header
**Attempting to validate AMap
**Attempting to validate BBT
**Attempting to validate NBT
**Attempting to validate BBT refcounts
??Couldint find BBT entry in the RBT (E025CC)
**Attempting to validate header NID high-water marks
**Beginning PST/OST recovery
**Attempting to recover all top-level objects
**Store created by biuld: 15.4517
**Attempting to walk all folders
Failed to add row to the FLT, RowID = 719
Failed to add row to the FLT, RowID = 6CD
Failed to add row to the FLT, RowID = 6DE
Failed to add row to the FLT, RowID = 6D8
and so on, and so on, with a few hundred more FLT RowID errors, finally ending with:
**Attempting to locate any orphaned folders/messages
**Performing Final HMP validation
**Attempting to check top-level objects for consistency
**Updating folder hierarchy
**Verifying message moves
My understanding of the Scanpst.exe process is that it also disables any addons which might cause crashing, but the issue is still being experienced. Running Scanpst.exe a second time (appending the previous log, although it seemed to actually prepend the
file) only returned a few lines from the top of the result above ending with "Attempting to validate BBT."
Fixes not attempted yet that I have found performing searches include running the Office Repair tool, or checking for KB2817631 (a Word update that is apparently having adverse affects on Outlook, not attempted yet because it seems to be related to the wwlib.dll
error, which is not happening here).
Any thoughts out there? Thanks!Mavis,
Thanks for the reply. Running Outlook using /cleansharing and
/cleanroamedprefs did not have any effect when used individually or in combination with each other.
Running the Search Index Rebuild option also did not seem to do anything, as the pop-up message indicated that it may take a long time to finish, and yet seemed to finish instantaneously, not giving any indication that the indexing took place. The option
window immediately said "Indexing complete" for 23,755 items.
As to the Outlook Forum, they are the ones who directed me to this forum (you can see the thread on the Answers support page under Office - Office 2013 - Microsoft Office Outlook - Office on Windows 7, under the title "Outlook 2013 restarts when
opening Calendar Search result item" first posted on Dec 11, 2013), as Girish M felt that it might be due to Exchange, and not Outlook. (I have no reports of any of our other users on the same Exchange server having the problem with their Outlook, but
they also do not use it the way this user has been.)
I can repost the issue there, or continue the same thread, if you think the issue lies with them. Was the "Answers" site the improper place to post, perhaps? Should it go in a different thread on Technet instead?
Thanks for your assistance!
Edited to add:
Here are the KBs installed just before or on the date the problem started (12/6/2013):
12/5/2016 (Office updates, all 32-Bit):
Security Update Office 2013 KB2768005
Office 2013 KB2768016
Office 2013 KB2817640
Office 2013 KB2827228
Security Office 2013 KB2837618
Word 2013 KB2817631
InfoPath 2013 KB2752078
Office 2013 KB2817493
Office 2013 KB2760539
Office 2013 KB2827235
Office 2013 KB2827225
Security Excel 2013 KB2827238
Office 2013 KB2760242
Office 2013 KB2817626
Office 2013 KB2817314
Office 2013 KB2760610
Access 2013 KB2768008
Office 2013 KB2738038
SkyDrive Pro KB2825633
Security Office 2013 KB2817623
Office 2013 KB2760267
Visio Viewer 2013 KB2768338
Office 2013 KB2827230
OneNote 2013 KB2810016
Office 2013 KB2827228
Office 2013 KB2767845
Definition Office 2013 KB2760587
Office 2013 KB2726996
Security Office 2013 KB2810009
Office 2013 KB2817316
Word 2013 KB2817631
Lync 2013 KB2817621
Office 2013 KB2760224
Office 2013 KB2726954
Office 2013 KB2817640
Publisher 2013 KB2752097
PowerPoint 2013 KB2817625
Office 2013 KB2760257
Office 2013 KB2817309
Security Outlook 2013 KB2837618
Visio 2013 KB2752018
Office 2013 KB2817490
Word 2013 KB2827218
Office 2013 KB2760553
12/6/2013 (for Windows, all Security):
KB2900986
KB2888505
KB2876331
KB2868725
KB2868626
KB2862152
I listed all updates because there have been reported instances of a Word update causing Outlook to crash, but she is not getting the wwlib.dll error related to that KB. If you are aware of any issues with these updates, and which ones might be worth uninstalling
in an attempt to fix, please let me know.
Thanks again! -
Error opening a Test Script inUFT from Solution Manager
This error is the subject of a call with SAP and HP but I wondered if anyone else has come across this problem.
We work with Solution Manager 7.1 (SP11) and HP's UFT 11.53 to create automated testing. We ustilise the two free seat licences for UFT that are provided via enterprise support. We do not use HP's Quality Centre.
On some occasions when trying to open a test script for editing UFT tries to open and then closes again. The error message below is displayed in solution manager.
“External Test Tool Quick Test Professional Is Busy and Cannot Create a New Test Script”
When this happens the local cache files are wiped. We have managed to salvage some of these scripts by pasting in copies of the cache file from another PC but some we had to recreate from scratch.If you don't have one already create a gateway instance on your Content Server.
Change or create the RFC destination : SAPKPROTP type = T
Check the radio button to start on Expicit Host
Enter the program = c:\winnt\sapkprotp.exe
Enter target host - use the hostname of the server for your Content Server
Enter the Gateway information
Regards,
Brian -
Relay Testing with State Machine
Hi,
Yesterday I very kindly had some help from "crossrulz" in setting out the following procedure. Today, the National Instruments representative called and said I should implement my programme as a "State Machine", which I have attempted in the programme attached. I was wondering how I might now implement the procedures 3 to 5 in this State Machine format as it seemed very complecated in the brief time we had.
What I am trying to do is test relays, using an automated test procedure.
The procedure takes the following steps:
1. A NI9472 DO card and transistor drive turns the relay on/off via energising the coil (needs the time period to be variable).
2. Counts how may cycles the relay contacts have operated, this will easily be in excess of 100,000 cycles.
3. Every 100 cycles (again variable), the contacts are held closed, the load circuit (the current the relay is switching, which will be 15A at 30V) is disconnected, via another relay and a measurement is taken via a separate four wire method. This consists of a 6V supply being placed across the contacts (switched in again via a relay) with a 1A current flowing through the contacts, the voltage drop across the contacts is then inputted into the NI AI NI9219 card (this is in the region of 10’s of mA) and is directly proportional to the contact resistance, which is what I want to measure.
4. The measurement is taken and stored and the measurement circuit disengaged, the load circuit re-engaged, and another 100 cycles is counted before the process goes back to stage 3.
5. This process goes on until the relay fails and hopefully a large set of contact resistance data is gathered.
I have no real experience with NI Labview.
I have looked at the basic academic tutorials and have come up with the following programme for stage 1, however I can't get the DAQ Assistant to output every cycle
Would this be a very difficult programme to implement for the novice? The academic tutorials seem straight forward but when I try to do someting it seems very difficult.
Hoping someone may be able to help, thanks
Andy
Solved!
Go to Solution.
Attachments:
Relay Test State Machine.vi 207 KB
Relay Test State Machine.vi 207 KBHi James,
I've tried to implement some logic as suggested. I can now get the 1A coil to engauge after the nth cycle and I think it's taking a measurement, but can't seem to get the 15 A coil to disengauge at the same moment, which is crucial else the measurement will be across 16 A rather than just the 1 A. Any ideas? I just want to get it working so we can get started with testing.
I'm going to get my supervisor to book me on a course at Newbury for future projects, it's very difficult to pick up of your own back.
Kind regards,
Andy
(Helps if I attach it)
Attachments:
Relay Test State Machine.vi 209 KB
Maybe you are looking for
-
Notes from my iPhone doesn't push to my air
I have enabled my icloud account on both my iphone and macbook air, but notes that I've saved on my phone will not push to my air. However, my contact information was shared as expected. Any thoughts? Thanks in advance.
-
Cisc ISE 1.1.3: PS not shown in Admin Node and no live authentications
Dear folks, I have a distributed deployment of ISE. 4 Applicances, two are Admin and Monitoring while remaining two are Policy Server. Policy Nodes are showing down... But, actualy they are running and working fine. Clients are being authenticated. I
-
Dear Experters, I got this problem, when I am doing my first workflow exercise,I tried to create a workflow from a standard Template(ws00000038(for Purchase requistion)).I followed the following steps In pftc event is activated Workflow stratergies n
-
System Update Problems - Windows XP 64bit with SP2
Hi, I have been Googling away but can't seem to fix my error when running System Update 3.14 on Windows XP 64bit with SP2. I keep getting the following error at 9-10%: "An error occurred while gathering user information" Has anyone managed to get thi
-
Lightroom 2 won't launch after install
After installing onto an XP 32-bit machine that already had Lightroom 2 Beta running, Lightroom 2 now refuses to launch. It is an upgrade version loaded from disc but has killed off all the other versions, too. I have un-installed and re-installed re