Hello,
  I am getting "Error 7" from the "Open VI Reference" vi, the name of the vi is wired vi path input. The "Error 7" means that the vi cannot be found. So I went to "Tools ===> Options ===> Paths" and modified the Path so that Labview can find it. But for reasons I do not understand the vi I want to get a reference for cannot be found. So it leads me to beleive that the "Open vi Reference" does not use the path option to find a vi. Any ideas what is going on?
Regards,
Kaspar
Solved!
Go to Solution.

Hello,
  Thanks for getting back to me. I have attached a file fo the screenshot of the Block diagram. The "Open Vi Reference" is in the upper left hand corner, which generates a error when I have updated the path options to point to where the file exists.
Regards,
Kaspar
Attachments:
vi_error.GIF ‏21 KB

Similar Messages

  • Error 1003 occured at Open VI Reference

    This error occured when I want to used the LabView Report Generation Toolkit for Microsoft Office Example.
    It's impossible for me to execute the example "Generate Report from Template(Excel)"
    I suppose I have a problem with the Open VI Reference.vi function but I don't know where is that VI.
    Could you let me know where are the VIs listed in the Application Control Pallette.
    Do you know why I have this type of problem.
    Thanks
    Lucie

    The VIs located on the application control palette are primitives and are part of LabVIEW itself. Therefore you can not look at their diagrams because they don't have one.
    However the 1003 error means that you are trying to dynamically load a VI that is not executable. I would suggest turning highlight execution on and following the code to see what path is sent into the Open VI reference function.
    Once you have the VI that is failing to open go manually open it.
    Chances are that it is broken, so see why it is broken. If I remember correctly there is a linking issue in that example, so you can open the VI that is broken and hit ctrl-shift-Run Button, and that should relink it all and fix the issue.
    If not take a look at this
    Why Do I Get Error 1003 From Application Builder When I Try to Build Excel Macro Example.VI?

  • Error 1004 occurred at Open VI Reference in Directory of Top Level VI.vi- Check Path.vi- Read PNG File.vi- ValveUI.xctl:LoadBackgroundImage.vi- ValveUI.xctl:Facade 1.vi:29- ValveUI.xctl:Facade 1.vi.ProxyCaller

    I am trying to dynamically load the background image of an XControl facade using a 'LoadBackgroundImage.vi' that I have written. This SubVI has worked with a normal VIs panel before. It utilizes the 'Read PNG File.vi' from Labview to read in a transparent PNG file to overwrite the Facade background. When the XControl is loaded during design-time it generates an Error 1004 indicating that the 'Read PNG File.vi' is not in memory. I have tried to place a static reference to this vi to force it to load but I still get this error. What is the solution?
    Attachments:
    Error Dialog.PNG ‏9 KB
    LoadBackgroundImage_VI.PNG ‏33 KB

    Darin, thanks for your reply.
    The XControl Facade is rendered on the Main FP when the Main.vi is opened in design mode. Previously I have placed a PNG image onto the Facade pane (i.e. drag-n-drop the image onto the Facade FP during design) and it is displayed on the Main.vi FP in design mode when Main is loaded. However, when I include a call to Read PNG File.vi in the Facade I get the 1004 error. You may not see this error without using a Simple Error Dialog. This failure to find Read PNG File.vi in memory is the main issue.
    I have tried to use SubPanels before - they are useless for my purposes for many reasons (they don't show the underlying SubVI pane in design mode, they require the use of SubVI references to load - preventing the use of direct wiring to the SubVI connector, etc.).
    Do you know how to dynamically load and call 'Read PNG File.vi' so that Labview is forced to load the VI and then Read PNG File can load the PNG image? I can get 'Read PNG File.vi' to dynamically load and show property values but to call it with the 'Call By Reference Node Function' I need a strict type def to be generated, etc. So what are the steps needed to create a dynamic call to 'Read PNG File.vi'? I haven't seen any good working examples that show how to create the strict typedefs that are required etc. There is no right-click > Make Type Def > ...  for Read PNG File.vi or other ways to do this that I have noticed. Showing a finished example doesn't show you how to do it (menu selections, etc.). Or, do I have to hand construct these typedefs by reverse engineering the VI?

  • Error 7 occurred at open vi reference in New Report.VI

    Hello!
    I use the report generation toolkit on LabView 7.0 to create a report in Excel. The program works fine until I make an executable version. I the get the error:
    Error 7 occurred at open vi reference in New Report.VI
    I use the New Report.VI, Bring Excel to front.VI and Save Report To File.vi
    Can you pleace help me!!!

    Most likely, you did not include the required libraries in your build script. When building an executable in which you use the Report Generation Toolkit, you must include the _Word Dynamic VIs.vi from _wordsub.llb and _Excel Dynamic VIs.vi from _exclsub.llb as dynamic VIs on the Source Files tab.
    Check this article for more info.
    http://digital.ni.com/public.nsf/3efedde4322fef19862567740067f3cc/86256a47004e16d186256a84004cb883?OpenDocument
    Daniel L. Press
    PrimeTest Corp.
    www.primetest.com

  • Open VI Reference Error in the executable version only

    Hello folks! I am having a strange issue since I updated to Labview 2014: I have a vi that uses "Open VI Reference" in order to programmatically open the desired vi. It worked flawless also in the compiled version (.exe) of the program until yesterday, when i compiled it again for the first time since my update to Labview 2014. It compiles with no problem, but when i start the exe and load the first vi it already gives me an error "Built Application or Shared Library (DLL): Missing".
    The point is that all the VIs that i want to open are inside an LLB that is supposed to be compiled inside the .exe: infact the path that i use to open is:
    D:\LabVIEW Data\builds\Sequenzer\Sequenzer2.0.exe\com_lv_sequenzer\trunk\Sequenzer_Functions.llb\Seq_Connect_to_Database.vi
    And i get error number 7:
    Open VI Reference in Seq_Function_Interface.vi->Sequenzer_Main_2.0.vi<APPEND>
    VI Path: <b>D:\LabVIEW Data\builds\Sequenzer\Sequenzer2.0.exe\com_lv_sequenzer\trunk\Sequenzer_Functions.llb\Seq_Connect_to_Database.vi</b>
    Built Application or Shared Library (DLL): Make sure all dynamically loaded VIs were properly included in the build specification for the application or shared library.
    LabVIEW Real-Time: VIs built into executables cannot be accessed through VI Server calls. Use Source Distributions to dynamically call VIs on Real-Time targets.
    The vi Seq_Connect_to_Database.vi is included in my built (as you can see in the attached screenshot and as it has always been).
    Do you have an idea of why it is not working anymore?
    Thanks a lot in advance!
    Dario Cassaniti
    Solved!
    Go to Solution.
    Attachments:
    sequenzer.png ‏86 KB

    OK, here is where I am confused. You talk about including the llb in the build, but in the screen shot you show a bunch of individual VIs being included. Next, in source file settings where are you telling the app builder to store all those individual VIs? Because they are VIs LabVIEW will, by default, want to put them in the executable somewhere.
    Mike...
    Certified Professional Instructor
    Certified LabVIEW Architect
    LabVIEW Champion
    "... after all, He's not a tame lion..."
    Be thinking ahead and mark your dance card for NI Week 2015 now: TS 6139 - Object Oriented First Steps

  • Open vi reference error

    Hi all,
    I am using LabVIEW 2011 SP1. I am running such a vi which is calling another vi by selecting a boolean button. After opening the new vi, the previous vi will stay opened but being minimized and the new vi will stay maximized untill user forces to close the new vi. All the operations are going successful at the start. But if we keep running it for 12-13hrs, then an error is coming in open vi reference of the previous vi and the previous vi becomes maximized and above the new vi. I have attached the error message herewith. Please give me a solution.
    Attachments:
    error.txt ‏1 KB

    Error 2 is a memory full error. If you right-click on the error cluster you can select "Explain Error". The most likely reason is that you are not closing your references properly, or you are not closing them at all. It could also be something else, such as continously building an array until you run out of memory. Without seeing some code it's impossible to say what the real cause is. If you cannot post your code then you will need to look at your code to see whether you are auto-disposing the VI references. If you are not, then you are responsible for closing them. If it's not a reference issue, then you should use the performance tools to monitor the memory usage of your VIs to see which one is causing unbounded increased memory usage.

  • Open VI Reference Error 1000

    Here is the problem:
    I am opening a VI (we will call SubVI) through "Open VI Reference" and running the VI in parallel with the VI (MainVI) that I am opening it from. When I run the MainVI using "Run when Opened", I get a Error 1000 and the SubVI freezes. I break out using ctrl-period. Then I start it up from within LabVIEW and the Error 1000 does not appear. Does anyone have an idea of what is going on? Thanks.

    I'm a bit unclear as to what your setup is. I suggest you post an example which will help clear it.
    As a guess, error 1000 means "The VI is not in a state compatible with this operation". If the subVI is the one set to be run when opened, maybe calling it dynamically is what causes the problem.
    Try to take over the world!

  • Error 7 occurred at Open VI Reference with Application Builder

    Using Labview 5.1, I am building an application where all the vi's are placed in a single .LLB file. I have one top level vi (with sub-vi's), and one vi that is opened by the Open VI command. The program runs fine with labview installed. I want to make an executable file. I select the top level vi and select the vi that is opened by the Open VI command as a dynamically loaded file. I get an error when I attempt to build the file.
    "Error 7 occured at Open VI Reference in Dist Build LLB Image.vi -> Dist Build App Image.vi -> Build application.vi"

    Dear Sir;
    There are two things that are good to try:
    First, create the application in a folder that is closer to the root directory (e.g., c:\myApp). There is a limit to the length (or depth) of the path name to your application's target directory, so, if you are choosing a too long path you might get an error.
    Second: The Application Builder reads certain information from the VI in order to determine how to build the executable. To avoid possible errors, either in the build process or in the built executable, make sure the VIs are LabVIEW 5.1 VIs. You can convert your VIs to LabVIEW 5.1 VIs by using the Mass Compile feature (File >> Mass Compile) in LabVIEW before you build your executable. The Mass Compile feature will allow you to select either a directory or a LabVIEW
    .llb file to compile.
    Regards

  • Error 7 occured at Open VI Reference in

    The error is actually displayed after each and every Printer VI like SetMagins, PageSize, AddField, CloseReport but NOT after the NewReport.vi Call!

    This error means that it can't find the file that you are trying to open a reference to. The file could either be missing or the path to it could be wrong.
    Mike...
    Certified Professional Instructor
    Certified LabVIEW Architect
    LabVIEW Champion
    "... after all, He's not a tame lion..."
    Be thinking ahead and mark your dance card for NI Week 2015 now: TS 6139 - Object Oriented First Steps

  • Error 1003 occurred at Open VI Reference in Dist Copy Non-VI Files.vi- Dist Build LLB Image.vi- Dist Build App Image.vi- Build Application.vi

    When trying to build  an application using labview 7.1 and windows XP,  I get the error
    Error 1003 occurred at Open VI Reference in Dist Copy Non-VI Files.vi->Dist Build LLB Image.vi->Dist Build App Image.vi->Build Application.vi
    I've tried the crtl-shift-run as well as  a mass compile and I still get the error.
    Any ideas?
    Thanks,
    Mike

    Hopefully this thread, or this KB article might help.
    It seems like this could come from a lot of things, but there's suggestions in those which might lead you in the right direction
    Message Edited by Day on 09-22-2006 02:07 PM

  • 高手快帮忙谢谢lab​view7打包后用到​7中新的new report.vi的​地方(选择的是wor​d)都提示error 7 occurred at open vi reference in new report.vi

    高手快帮忙谢谢
    labview7打包后用到7中新的new report.vi的地方(选择的是word)都提示error 7 occurred at open vi reference in new report.vi。
    下面提示的可能原因是Possible reason(s):
    LabVIEW:  File not found. The file might have been moved or deleted, or the file path might be incorrectly formatted for the operating system. For example, use \ as path separators on Windows, : on Mac OS, and / on UNIX.
    我愿自己是个胡萝卜,可以自己自足啦!

    我明白您的意思,也可以按您所说的作,
    但是open vi peference这个vi是labview提供的标准new report.vi的子vi中使用到的,如果我手动修改open vi peference中的提供的word路径,也就是说labview提供的模块也要自己修改了??
    我愿自己是个胡萝卜,可以自己自足啦!

  • Error 1003 At Open VI Reference

    I'm calling a VI from a library using the Open VI Reference. The main program in an executable file. If I make a change to the *.llb and try to call it using the main program I get an error 1003 Open VI Reference is not executable. Now I've made changes to the *.llb in the past and never got this error before, but this time I can't run the *.llb anymore. What is my issue?

    Are you able to call the VI in the .llb correctly right after you build the executable? In other words, do you get the error only after making changes to the VI?
    As long as you don't change the name of the VI in your .llb, you should be able to make changes to it and still run it from your executable.
    How are you referencing the VI from the code in the executable? Are you using the absolute or relative path? Is all of this happening on your development machine, or are you moving the executable and .llb to a different machine?
    Robert Mortensen
    Software Engineer
    National Instruments

  • Dynamically called VI becomes broken inside an executable. Error 1003 from "Open VI Reference".

    Here's the problem. Dynamically called VI becomes broken inside an executable in debug executable mode Error 1003 is occuring from "Open VI Reference" Block. The computer has all of the necessary drivers, NI-VISA and NI-DAQmx. This executable is a new release of software that currently works on the PC in question. I can using NI-VISA Remote Server control the instruments from my PC using the executable. But when I put the executable on the PC I am getting this error. The only way I have been able to get this to work properly is to build the executable from the console I believe the project was created in, note that the project file has been moved to a network drive and it still works. All of the stations I have opened the project in show the VI that is being called is runnable. I've tried building the executable from the console I am deploying to and the same thing happens.
    I am honestly at a loss for ideas why this is occuring. Is this something about the way LabView works internally that may be causing this problem?
    I have trolled this forum for idea's and none have made sense to me.
    Any input would be greatly appreciated.
    -Nate

    Two ideas:
    Mass compile the project to ensure all linkages are ironed out
    Include the dynamically launched VI's into the "Always Included" section of the build spec
    Report back on if either of these actions solves your problem.
    a.lia-user-name-link[href="/t5/user/viewprofilepage/user-id/88938"] {color: black;} a.lia-user-name-link[href="/t5/user/viewprofilepage/user-id/88938"]:after {content: '';} .jrd-sig {height: 80px; overflow: visible;} .jrd-sig-deploy {float:left; opacity:0.2;} .jrd-sig-img {float:right; opacity:0.2;} .jrd-sig-img:hover {opacity:0.8;} .jrd-sig-deploy:hover {opacity:0.8;}

  • I recently got a new computer because my old one wouldn't let me open creative suite 3 after it generated a error and now I can't deactivate the key to activate it onto my new account.

    I recently got a new computer because my old one wouldn't let me open creative suite 3 after it generated a error and now I can't deactivate the key to activate it onto my new computer. Any help would be appreciated. Thank you.

    You are allowed to have two activted installations, so if the first machine is the only machine with an activated installation there is nothing prohibiting you from installing and activating on the new machine.
    You can contact Adobe Support thru chat to have the old installation deactivation.
    Serial number and activation support (non-CC)
    http://helpx.adobe.com/x-productkb/global/service1.html ( http://adobe.ly/1aYjbSC )

  • LV 8.2.1 Error 66 or 1379 occured at open Application Reference. A LV 8.2.1

    Hi,
    LV 8.2.1 Error 66 or 1379 occured at open Application Reference. A LV 8.2.1
    Using:
    Application access an other LV application on an remote PC with Vi-Server Technology. (Based on MS OS Windows XP SP2 with all patches ...)
    With LabVIEW 8.2.1 it is not possible (exactly: with one PC it works, with other PCs, (identical regarding configuration of LabVIEW-Components), the described errors occured ...
    There is no problem with LV 7.1.1. ( If the VI-Server Configuration of the .exe will be done within the .ini -File...)
    The differences between LV 7.1.1 are in the .ini-File of the application regarding the the access-List property.
    Error 66 occures if ther is no entry in the access-List property.-> OK.
    Error 1379 occures if i will use the copy of the LV .ini-File acl-property with allowed access from all clients (*) or special clients defined with IP-Adress ... -> BUG
    The same behaviour is described in 2 threads in the discussion forum ..., but in my application/configuration the workaround acl.configuration: "allow access from all clients" will work only with one PC ?
    So what is the solution ?
    At this moment i gol back to LV 7.1.1, but this is surely not the solution ....
    Thanks for help ....

    Hi!
    I have also found following discusion in the forum.
    But the the problem for Error 1379 lies in LabVIEW 8.2.1 and VI Server.
    This is a know Bug. This Bug should be fixed in a future version.
    The problem is that the IP address in the could not be resolved into a machine name.
    Workaround:
    This program works in 7.1 so the only option right now is to use 7.1 instead of 8.2.1.
    Plamen
    Message Edited by Support on 10-31-2007 08:59 AM
    National Instruments Germany
    Application Engineer

Maybe you are looking for