Oracle Fulfillment server does not start and also my concurrent manager is

The oracle Fulfillment server does not start and also my concurrent manager is down, when ever iam trying to start them i getting error.
even i restarted my laptop many times
Iam using WINXP on my laptop.
Pls help someone
hsawwan
Posts: 11,859
Registered: 03/13/06
Re: oracle Fulfillment server and concurrent manager problem
Posted: Oct 13, 2008 9:26 AM in response to: user578071 Reply
What is the error?
What does CM log file say?
Please run cmclean.sql and try to start the CM then.
Note: 134007.1 - CMCLEAN.SQL - Non Destructive Script to Clean Concurrent Manager Tables
https://metalink.oracle.com/metalink/plsql/ml2_documents.showDocument?p_database_id=NOT&p_id=134007.1
where should i run in apps schema or some other schema, where can i find the log
as iam using r12

Duplicate thread ..
oracle Fulfillment server and concurrent manager problem
Re: oracle Fulfillment server and concurrent manager problem

Similar Messages

  • Oracle service, Listener and http server does not start automatically

    Hello,
    I have Oracle 9i release 2 installed on Unix HP box if system restart in case of power failure the Oracle service, Listener and http server does not start automatically, is there any ready reference available to check what's wrong is happening(I don't have knowledge of Unix).
    Thanks, Khawar.

    Hi Rajesh,
    Thanks for reply, I will check this link and will be back if facing problem.
    Regards, Khawar.

  • Calendar server does not start

    We installed an OCS onebox 90411 on Win 2000 Server in january. Since last week calendar server does not start:
    D:\ocs_onebox\mtier\ocal\bin\unistart
    unistart: Oracle Calendar Server 9.0.4
    unistart: Copyright (c) 1993, 2003, Oracle.
    unistart: All rights reserved.
    unistart:
    unistart: Starting the Calendar Lock Manager
    unistart [error]: Error starting the Calendar Lock Manager
    unistart [error]: More details can be found in 'D:\ocs_onebox\mtier\ocal\log\unistart.log'
    unistart [error]: and in 'D:\ocs_onebox\mtier\ocal\log\lck.log'.
    Last entry in lck.log is from january.
    Last entries in unistart.log:
    DATE = Wed Apr 14 21:44:02.718 2004
    PID = 5336; TID = 5332
    ERROR CODE -> 0x50B05
    FUNCTION NAME -> ADM_Service::Start()
    SIS_ServerStart failed ((unilckd) SIS_ServerStart: StartService error :1069,Der Dienst konnte wegen einer fehlerhaften Anmeldung nicht gestartet werden. )
    DATE = Wed Apr 14 21:44:02.734 2004
    PID = 5336; TID = 5332
    ERROR CODE -> 0x50B05
    FUNCTION NAME -> Unistart::ProcessLocalStartServer()
    Error starting the Calendar Lock Manager. (unilckd) SIS_ServerStart: StartService error :1069,Der Dienst konnte wegen einer fehlerhaften Anmeldung nicht gestartet werden.
    Any idea ?

    Hi,
    Please log a TAR for this issue.
    Thanks,
    Lily

  • Application server does not start for DMO

    Hi,
    I have a HR91DMO system on Win 2008.
    Application server does not start. From Tuxedolog :
    105938.IRNTSV-DVPSPJ2!PSAPPSRV.4728.4944.0: LIBTUX_CAT:250: ERROR: tpsvrinit() failed
    105938.IRNTSV-DVPSPJ2!tmboot.244.3628.-2: tmboot: CMDTUX_CAT:827: ERROR: Fatal error encountered; initiating user error handlerAnd here is my cfg file :
    ;=========================================================================
    ; Database Signon settings
    ;=========================================================================
    DBName=MYDB
    DBType=ORACLE
    UserId=PTWEBSERVER
    UserPswd=***
    ConnectId=people
    ConnectPswd=***people user can connect in sqlplus to DB. SYSADM can connect via datamover.
    Any help ? thank you.

    SELECT CLASSID, STARTAPPSERVER FROM PSCLASSDEFN
    WHERE CLASSID IN (SELECT OPRCLASS FROM PSOPRCLS WHERE OPRID='<OPRID>')
    If above sql returns a row where STARTAPPSERVER=1, then the user <OPRID> can start the application server.
    If not update a permission list <CLASSID> that is assigned to <OPRID> (result aboce sql), using below sql.
    UPDATE PSCLASSDEFN SET STARTAPPSERVER=1 WHERE CLASSID='<CLASSID>'
    Also see the installation manual CHAPTER 8A - Configuring the Application Server on Windows - Prerequisites
    Hakan

  • Just installed Firefox 3.6. Firefox will not start and Firefox safemode does not start either. Using Task manager I do not see if started either. If I create a new profile and start from that window, Firefox starts up. I see no error windows/messages. I d

    Just installed Firefox 3.6. Firefox will not start and Firefox safemode does not start either. Using Task manager I do not see if started either. If I create a new profile and start from that window, Firefox starts up. I see no error windows/messages. I do have it listed in my Firewall as an exception program with Permit All. What is happening?
    == This happened ==
    Every time Firefox opened
    == After removing Firefox and Reinstalling it. ==
    == User Agent ==
    Mozilla/4.0 (compatible; MSIE 7.0; Windows NT 5.1; GTB6.4; .NET CLR 1.1.4322; .NET CLR 2.0.50727; .NET CLR 3.0.04506.30; .NET CLR 3.0.04506.648; MS-RTC LM 8)

    If that new profile works then you can transfer some files from the old profile to that new profile (be careful not to copy corrupted files)
    See http://kb.mozillazine.org/Transferring_data_to_a_new_profile_-_Firefox
    See also [[Basic Troubleshooting|#Make_a_new_profile|Basic Troubleshooting: Make a new profile]]

  • Compiler warning: Source folder "server" does not exist and will be ignored

    Hi,
    i am using NWDS 7.0 SP16. I have a development component type "J2EE Sever Library", which uses a java component. Everything works fine, except during the build i get a warning "Warning: Source folder "server" does not exist and will be ignored.".
    Then i created the folder named "server" manually, but the build finished again with warning, now saying:
    "Warning: Source folder "server" exists but is empty and will be ignored."
    I created a dummy-file in the directory "server" and now the compilation is fine, no warnings.
    I like to get my build free of any warnings, so what's wrong here? I found no documentation to create the folder/file manually.
    Any help is appreciated.
    Regards,
    Thomas

    Hi Raman,
    I am also getting the same error . i moved my srm transports from DEV to QA and replicated the datasources into BI . and then i moved the BW transports from dev to QA.
    when i check the datasource it is pointing to D60 instead of Q60 . when i check the transformations getting the same error :
    source system dosen't exist.
    can you please let me know how you resolved this issue. your reply will be  highly appreciated.
    Regards,
    Sri

  • J2EE 5 sneak preview:Server does not start

    Hi,
    I need some help since after installation of the sneak preview 5 I could not start the server.
    The db and the central instance are running but not the server.
    1)I get always time out error"StartWait
    FAIL: process jstart.exe J2EE Server not running
    The WAS is installed on a USB2 hard disk.
    2)Furtheremore I cannot operate on the SAP management Console since I get Authorization error.
    I installed the was with windows user IT/paceg
    which is by Domain IT accessible even if I am not in the Domain.
    Anyone can help me,please?
    thanks
    Bye,
    Giamma
    ===================================================
    ============== Starting System JP1 ================
    ===================================================
    =============== Starting database instance ...
    Servizio richiesto già avviato.
    Ulteriori informazioni sono disponibili digitando NET HELPMSG 2182.
    The MaxDB Database Starter, Version 7.6.00.33
    Copyright 2000-2006 by SAP AG
    OK
    ============== Starting central services instance ...
    09.10.2006 12:37:21
    Start
    OK
    09.10.2006 12:37:21
    StartWait
    OK
    ============== Starting java instance ...
    09.10.2006 12:37:21
    Start
    OK
    09.10.2006 12:38:36
    StartWait
    FAIL: process jstart.exe J2EE Server not running
    ============== Start operation timed out !
    Premere un tasto per continuare . . .

    Just for update:
    The error means that the message server is not able to translate the IP address into the hostname (reverse name lookup). If this fails the Startup Framework cannot connect to the message server and the server does not start. Please check the network setup on this host.
    Replay:
    thanks to all.
    all is done:Just insert my loopback ip 10.10.0.10 in file host resolving on my host name romnb120.
    Regards Galin

  • Connection Server does not start

    Hello guys,
    The Connection Server does not start anymore.
    When I always try to start it returns me a failed status and shows me that the server is considered failed because it has stopped 5 time(s) in 60 minute(s).
    It's a BOE XI 3.1 SP2 with IK 3.1 SP2 installed on a Windows 2003 Server.
    BO XI database is on a SQL Server and all tables are there and seems to be OK
    The log file for the connectserver via trace is below :
    2010/01/28 19:06:43.339|>>| | | 4524|4528| |||||||||||||||TraceLog::Admin: logdir ('C:/Program Files/Business Objects/BusinessObjects Enterprise 12.0/Logging/')
    2010/01/28 19:06:43.339|>>| | | 4524|4528| |||||||||||||||TraceLog::Admin: update ()
    2010/01/28 19:06:43.339|==| | | 4524|4528| |||||||||||||||TraceBridge::Initialize: pullable set to 1
    2010/01/28 19:06:43.339|==| | | 4524|4528| |||||||||||||||TraceLog state:
    // device_info
    // process        (process#pid)   = ConnectionServer#4524
    // device         (name#deviceid) = ConnectionServer#MainDevice
    // pull/push      (pullable)      = Pull
    // pull mode settings
    //   configfile   (ini)           = C:\Program Files\Business Objects\BusinessObjects Enterprise 12.0\Logging\logConfig\BO_trace.ini
    //   every ... s  (period)        = 60
    // config
    active        = true;
    severity      = 'W';
    importance    = '<<';
    keep          = true;
    always_close  = false;
    log_dir       = "C:/Program Files/Business Objects/BusinessObjects Enterprise 12.0/Logging/";
    2010/01/28 19:06:43.402|==| | | 4524|4528| |||||||||||||||SIServerController:run: Fail to initialize or uninitialize.  Reason is The root server reported an error Unknown.:
    2010/01/28 19:06:43.402|==| | | 4524|4544| |||||||||||||||SIServiceStopThread::run: SIServiceStopThread::run exited
    2010/01/28 19:06:43.402|==| | | 4524|4528| |||||||||||||||CsContainer::uninitialize
    2010/01/28 19:06:43.402|==| | | 4524|4528| |||||||||||||||TransientObjectMonitor stopMonitor()...
    .\siserver.cpp:974: TraceLog message 11
    2010/01/28 19:06:43.402|>>|A| | 4524|4528| |||||||||||||||assert failure: (.\siserver.cpp:974). (false : SIServerController::run: Unknown exception caught in server's uninitialization function).
    Any help please?!
    thank you very much.
    Cesar

    Hello,
    I have the same problem (Connection Server does not start).
    I'am under BOXI R2 SP6 (unix) and i have this error in my log when i want to start ConnectionServer :
    Timestamp       ProcessID       ThreadID        Message
    [Fri May  7 07:37:09 2010]      31154   1103673168      Log: level=3 cat=1 msg=35100 p=ConnectionServer started
    [Fri May  7 07:37:09 2010]      31154   1103673168      trace message: SIServerController::run: Before initialize
    [Fri May  7 07:37:09 2010]      31154   1103673168      (sidaemon.cpp:416): trace message: SUNIXDaemon::init: starting
    [Fri May  7 07:37:09 2010]      31154   1103673168      trace message: SUNIXDaemon::init: redirecting stdio to /dev/null
    [Fri May  7 07:37:09 2010]      31154   1103673168      (sidaemon.cpp:209): trace message: installing fg terminiation handler
    [Fri May  7 07:37:09 2010]      31154   1103673168      (sidaemon.cpp:220): trace message: installing abnormal sys handler
    [Fri May  7 07:37:09 2010]      31154   1103673168      (sidaemon.cpp:506): trace message: SUNIXDaemon::init: finished
    [Fri May  7 07:37:09 2010]      31154   1103673168      Log: level=0 cat=14 msg=35101 p=The root server reported an error Unknown.
    [Fri May  7 07:37:09 2010]      31154   1103673168      trace message: SIServerController:run: Fail to initialize or uninitialize.  Reason is The root server reported an error Un
    known.:
    [Fri May  7 07:37:09 2010]      31154   1103673168      trace message: CsContainer::uninitialize
    [Fri May  7 07:37:09 2010]      31154   1103673168      trace message: TransientObjectMonitor stopMonitor()...
    [Fri May  7 07:37:09 2010]      31154   1103673168      Log: level=0 cat=14 msg=35101 p=The root server reported an error Internal Error. (Reason: Unknown exception caught in ser
    ver).
    [Fri May  7 07:37:09 2010]      31154   1103673168      assert failure: (siserver.cpp:953). (false : SIServerController::run: Unknown exception caught in server's uninitializatio
    n function
    [Fri May  7 07:37:09 2010]      31154   1103673168      Log: level=3 cat=1 msg=35100 p=ConnectionServer stopped
    Any idea ?
    Thanks.

  • HTTP Server does not start -- 9ias 1.0.2.2.0

    HTTP Server does not start -- 9ias 1.0.2.2.0
    Installed 9iAS Enterprise Edition. Whole installation went well. Finally when I reboot the machine, the HTTP Service does not start.
    When I try to start the service it gives "Could not start OracleiSuitesHTTP server service on \\clwrd1 Error: 2140 An internal Windows NT Error Occured"
    Event log does not show any errors..
    Any help is appreciated.
    Thanks
    Bala

    I have Oracle 9iAS installed but sometimes the HTTP server stops responding. it searches for all the .html files. but it can not find the .jsp files in the specified path. is there anything wrong with the apache configuration?
    httpd.conf is perfectly alright.
    It give the following error
    Request URI:/testFile.jsp
    Exception:
    javax.servlet.ServletException: java.io.FileNotFoundException: ...\testFile.jsp (The system cannot find the file specified)
    now what to do??
    plz help
    thanx
    ketan malekar
    ([email protected])

  • My Imac does not start and make a terrible noise like an alert.

    Please help me, my Imac does not start and make a terrible noise like an alert when try to start ,the Imac keep a grey screen when try to start and keep there.

    Sounds like it is time  to take it to an Apple Store or AASP to be serviced. You can also try troubleshooting using Apple's Gray screen appears during startup instructions.

  • Server does not start using Sun Java SE 1.5.0_07

    The application server launched with startserv using Sun Java SE 1.5.0_07 , seems to hang (uyner SuSE Linx 10.1), it does not start, and stays forever in startserv. performing a kill -3 for the precess we have:
    "process reaper" daemon prio=1 tid=0x08459ab8 nid=0x1bc8 runnable [0xa8c01000..0xa8c01e50]
    at java.lang.UNIXProcess.waitForProcessExit(Native Method)
    at java.lang.UNIXProcess.access$900(UNIXProcess.java:20)
    at java.lang.UNIXProcess$1$1.run(UNIXProcess.java:132)
    "Low Memory Detector" daemon prio=1 tid=0x080c7720 nid=0x1bc6 runnable [0x00000000..0x00000000]
    "CompilerThread0" daemon prio=1 tid=0x080c6178 nid=0x1bc5 waiting on condition [0x00000000..0xaa2c09b8]
    "Signal Dispatcher" daemon prio=1 tid=0x080c5100 nid=0x1bc4 runnable [0x00000000..0x00000000]
    "Finalizer" daemon prio=1 tid=0x080b9b88 nid=0x1bc3 in Object.wait() [0xaa3fc000..0xaa3fd0d0]
    at java.lang.Object.wait(Native Method)
    - waiting on <0xaaa77568> (a java.lang.ref.ReferenceQueue$Lock)
    at java.lang.ref.ReferenceQueue.remove(ReferenceQueue.java:116)
    - locked <0xaaa77568> (a java.lang.ref.ReferenceQueue$Lock)
    at java.lang.ref.ReferenceQueue.remove(ReferenceQueue.java:132)
    at java.lang.ref.Finalizer$FinalizerThread.run(Finalizer.java:159)
    "Reference Handler" daemon prio=1 tid=0x080b8e38 nid=0x1bc2 in Object.wait() [0xaa47e000..0xaa47e150]
    at java.lang.Object.wait(Native Method)
    - waiting on <0xaaa775e8> (a java.lang.ref.Reference$Lock)
    at java.lang.Object.wait(Object.java:474)
    at java.lang.ref.Reference$ReferenceHandler.run(Reference.java:116)
    - locked <0xaaa775e8> (a java.lang.ref.Reference$Lock)
    "main" prio=1 tid=0x0805d5f8 nid=0x1bc0 runnable [0xbfb3a000..0xbfb3b2d8]
    at java.io.FileInputStream.readBytes(Native Method)
    at java.io.FileInputStream.read(FileInputStream.java:194)
    at java.io.BufferedInputStream.read1(BufferedInputStream.java:254)
    at java.io.BufferedInputStream.read(BufferedInputStream.java:313)
    - locked <0xaaa79d20> (a java.io.BufferedInputStream)
    at sun.nio.cs.StreamDecoder$CharsetSD.readBytes(StreamDecoder.java:411)
    at sun.nio.cs.StreamDecoder$CharsetSD.implRead(StreamDecoder.java:453)
    at sun.nio.cs.StreamDecoder.read(StreamDecoder.java:183)
    - locked <0xaa591480> (a java.io.InputStreamReader)
    at java.io.InputStreamReader.read(InputStreamReader.java:167)
    at java.io.BufferedReader.fill(BufferedReader.java:136)
    at java.io.BufferedReader.readLine(BufferedReader.java:299)
    - locked <0xaa591480> (a java.io.InputStreamReader)
    at java.io.BufferedReader.readLine(BufferedReader.java:362)
    at com.sun.enterprise.tools.launcher.ProcessLauncher.sendInputToProcessInput(ProcessLauncher.java:410)
    at com.sun.enterprise.tools.launcher.ProcessLauncher.executeBackgroundCommand(ProcessLauncher.java:352)
    at com.sun.enterprise.tools.launcher.ProcessLauncher.executeCommand(ProcessLauncher.java:327)
    at com.sun.enterprise.tools.launcher.ProcessLauncher.process(ProcessLauncher.java:238)
    at com.sun.enterprise.tools.launcher.ProcessLauncher.main(ProcessLauncher.java:158)
    "VM Thread" prio=1 tid=0x080b61b0 nid=0x1bc1 runnable
    "VM Periodic Task Thread" prio=1 tid=0x080c8bd8 nid=0x1bc7 waiting on condition

    The recommended way of starting the application server is to use asadmin command, for ex. <application-server-install-root>/bin/asadmin start-domain. The reason startserv hangs is because it is expecting some input which is automatically provided by the asadmin command.
    - sreeni

  • Garageband does not start and I get this open and do not shut down or restart

    garageband does not start and I get this open and do not shut down or restart

    Such an error is always caused by inconsistent files in the Firefox program folder (application.ini and/or platform.ini and possibly others) and your only option is to reinstall that version of Firefox, either via the software repositories or the Mozilla server.<br />
    Be sure to delete all files in that folder before copying the files from that tar.bz2 archive.<
    *http://kb.mozillazine.org/Installing_Firefox#Linux
    Note that the current ESR version is 10.0.5
    *http://www.mozilla.org/en-US/firefox/organizations/all.html
    *http://www.mozilla.org/en-US/firefox/17.0.5/releasenotes/
    *http://www.mozilla.org/en-US/firefox/17.0.5/system-requirements/
    All Firefox releases:
    *https://ftp.mozilla.org/pub/mozilla.org/firefox/releases/ (17.0.5esr/, latest-esr/, latest/)

  • SAP MMC does not start and red in color

    Hi Gurus,
    We are in a process of installing EhP4 and there were lots of errors. We reverted back to old version.
    After moving back to old state i.e., EhP3, system does not start.
    1. SAPosCol does not start acutomatically in the service
    2. sapmmc does not show database details
    3. When I try to start the server through SAPMMC, all esmart03 0, esmart03 1 turns to red.
    Please let me know how i can fix this problem.
    I want to post screen shot, but i am not sure how i can post the same here.
    Thanks in advance.
    Regards
    Shreeshail

    Thanks Sunny for your reply.
    We had taken system system backup (complete "E" drive) where SAP server is installed. I had to stop EhP4 process as we got a requirement to bringup NWBC.
    We restored the "E" drive content and then restarted the SAP server.
    After that servies did not start and MMC does not show up Database details.
    Do i need to create services and MMC to fix the issues??
    Thanks in advance.
    Regards
    Shreeshail

  • The Connection Server does not start after an upgrade to BO4.1 SP3

    Hello guys,
    The Connection Server does not start after an upgrade to BO4.1 SP3
    We are in process to upgrade our Business Objects environments to BO4.1 SP3
    The first 2 environments , the upgrade went fine. But the third environment de connection server won’t start.
    When I always try to start it returns me a failed status and shows me that the server is considered failed because it has stopped 5 time(s) in 60 minute(s).
    Our OS is AIX
    Uncaught Exception in SilentScope: [CS] Ser
    verInitialization::InitManager::Initialize: 0.007^^
    The CS initialization failed within the CS server. Aborting
    trc file: "connectionserver_BIO.ConnectionServer_ncs.trc", trc level: 1, release: "720"
    Gerd

    Hi Amine
    The File seems ok
    File from the failing connection server
    -rw-rw---- 1 bioadm bosys 43993 Apr 11 11:29 boconfig.cfg
    File from our test system
    -rw-rw---- 1 bitadm bosys 43892 Apr 14 10:56 boconfig.cfg
    I created a new connectieserver(by the copy function), but the new server won't start.
    Regards
    Gerd
    Log
    |89d4a6e0-2a89-7a05-3020-a51d517ab872|2014 04 14 11:54:30:113|+0200|Error| |>>|E| |connectionserver_BIO.ConnectionServer|28246236|3097|| |0|0|0|0|-|-|-|-|-|-||||||||||||[CS] Unhandled exception raised during CS initialization.
    init_srv.cpp:95:-: TraceLog message 3
    |4dcf04b1-1e1d-df13-48ad-a67f06e29864|2014 04 14 11:54:30:113|+0200|Error| |<<|E|X|connectionserver_BIO.ConnectionServer|28246236|3097|| |0|0|0|0|-|-|-|-|-|-||||||||||||Uncaught Exception in SilentScope: [CS] ServerInitialization::InitManager::Initialize: 0.003
    |77ad78f4-37f7-3013-3b50-85cce9fbe7b8|2014 04 14 11:54:30:113|+0200|Error| |>>|E| |connectionserver_BIO.ConnectionServer|28246236|3097|| |0|0|0|0|-|-|-|-|-|-||||||||||||[CS] The CS initialization failed within the CS server. Aborting.

  • Hp probook 4420s does not start and continuous​ly cap lock blinks

    I have tried-------
    1. Bios Recovery ( used windows key and B and power button)
    2.  changed the memory to another slot
    3. Power button holding 3 times (15-20 sec) without connect AC & DC
    Still remain the same problem:
    Computer does not start and contineously blinking the cap lock
    Note: Using Windows 7, when I updated then suddenly shut down the computer and does not start.

    Try a hard reset as follows:
    1) Remove the battery and unplug the DC power adapter.
    2) Press and hold the power button for more than fifteen seconds.
    3) Plug in the DC power adapter (leave the battery out for now)
    4) Press the power button
    Please post your positive or negative results here in your thread.
    Your notebook does not have Windows 8 installed, but almost everything in this troubleshooting document applies. Take a look at the blinking leds section. Blink codes are a diagnostic aid and the sequence of blinks repeat. There is a list which will tell you what the repeating blinks mean.
    ****Please click on Accept As Solution if a suggestion solves your problem. It helps others facing the same problem to find a solution easily****
    2015 Microsoft MVP - Windows Experience Consumer

Maybe you are looking for