Orion shows 3750 port speed changes - is it normal?
Hi all,
We use Orion for monitoring. We recently started monitoring a workstation switch and find many occurances of port speed changes indicated. Our workstation ports are configured with auto speed and duplex. Is it normal that we are detecting speed changes on the ports? Do workstations running XP automatically adjust their speed for traffic management or power save? Perhaps something like speeds changing when PC goes to sleep mode but has wake on LAN enabled? Is it possible that the MIB is misreporting?
I realize that there are many different NIC vendors/drivers that might act differently. Just wondering (in others experience) if it is somewhat normal or if there is anything on network I should be looking into as to why speeds are changing? We plan to not monitor workstation ports (only uplinks) on the switch.. but before we do, I thought I would see if what we are detecting needs to be addressed?
Here is an example from Orion of a speed changing. Seems always off hours:
6/1/2012 6:17:52 AM
event
WoRKSTATION-3750-CLUSTER - GigabitEthernet1/0/14 · 2nd Floor Patch#11 Interface Speed changed from 10000000 to 1000000000 bps
6/1/2012 2:47:52 AM
event
WoRKSTATION-3750-CLUSTER - GigabitEthernet1/0/14 · 2nd Floor Patch#11 Interface Speed changed from 1000000000 to 10000000 bps
Thanks in advance for any experienced feedback.
Colin
Ours does it all the time for some reason. We presume it's due to the port negotiating speed during PC boot from 100mb to 1g, but never really followed up.
Similar Messages
-
Cisco Prime Infrastructure 2.1 wired client show Wrong port speed.
Hi,
i have odd issue for some reason the port speed in the wired clients shown a wrong speed,
can some explain how the speed detremained and why i'm getting a wrong speed port of 10mb for a pc/host when my network is at least 100mb,
thanksHi all,
after a TAC with cisco they open a new BUG # CSCur33328
https://tools.cisco.com/bugsearch/bug/CSCur33328/?reffering_site=dumpcr
thanks -
I connect a copper SFP on port 2 of WLC 5508 to a ASA 5510 firewall. The links between two devices are down. Since ASA 5510 only support 100 full, how do I change port speed on port 2 to 100.
ThanksDoes this mean, I couldn't change port speed on the WLC?
Yes you can. You can change the speed setting to GIGABIT, nothing less.
Why do I need to buy another Gigbit switch for 2 connection?
What do you mean by "another"???? Do you have an existing GigabitEthernet switch that you can connect the WLC into?
You need a GigabitEthernet port to connect the WLC's GigabitEthernet port. And then you can have a FastEthernet port to connect the SAME SWITCH to your ASA.
WLC --- (1000BaseTx) --- Switch --- (10/100BaseTx) --- ASA
Does this make sense to you? -
Changing Catalyst 3750 Console Speed
Does anyone know if the console speed of a Catalyst 3750 can be changed? The switch does not have a valid IOS image installed and the only prompt accessible is the Switch: recovery console prompt. Before using the xmodem I am hoping there is a way to increase the baud rate to speed things up a bit.
Check out document:
http://www.cisco.com/en/US/products/hw/routers/ps282/products_installation_guide_chapter09186a008007dfca.html
It available witout a login. Look in the section:
"Modifying the Configuration Register in Menu Mode"
Good info to print and keep on hand, cuz when you need it...
HTH.
Jim -
My N2K connected to N5K, why some ports can set the port speed, and some cann't set the port speed?
int eth102/1/25 !!!No speed command
(config-if)# ?
beacon Disable/enable the beacon for an interface
cdp Configure CDP interface parameters
channel-group Configure port channel parameters
description Enter description of maximum 80 characters
inherit Inherit a port-profile
ip Configure IP features
ipv6 Configure IPv6 features
lacp Configure LACP parameters
link Configure link
lldp Configure Interface LLDP parameters
logging Configure logging for interface
mvr-group MVR interface config
mvr-type MVR interface config
mvr-vlan Interface MVR Config
no Negate a command or set its defaults
rate-limit Set packet per second rate limit
service-policy Configure service policy for an interface
service-policy Policy Map
shutdown Enable/disable an interface
snmp Modify SNMP interface parameters
spanning-tree Spanning Tree Subsystem
switchport Configure switchport parameters
untagged Default to use for untagged packets on interface
end Go to exec mode
exit Exit from command interpreter
pop Pop mode from stack or restore from name
push Push current mode to stack or save it under name
where Shows the cli context you are in
(config-if)# int eth102/1/48 !!! include speed command
(config-if)# ?
bandwidth Set bandwidth informational parameter
beacon Disable/enable the beacon for an interface
cdp Configure CDP interface parameters
channel-group Configure port channel parameters
default Set a command to its defaults
delay Specify interface throughput delay
description Enter description of maximum 80 characters
duplex Enter the port duplex mode
fex Configure FEX fabric
flowcontrol Configure interface flowcontrol
hardware FEX Card type
inherit Inherit a port-profile
ip Configure IP features
ipv6 Configure IPv6 features
lacp Configure LACP parameters
link Configure link
lldp Configure Interface LLDP parameters
load-interval Specify interval for load calculation for an interface
logging Configure logging for interface
mac MAC
mac-address Configure interface mac address
mvr-group MVR interface config
mvr-type MVR interface config
mvr-vlan Interface MVR Config
negotiate Configure link negotiation parameters
no Negate a command or set its defaults
priority-flow-control Enable/Disable PFC
rate-limit Set packet per second rate limit
service-policy Configure service policy for an interface
service-policy Policy Map
shutdown Enable/disable an interface
snmp Modify SNMP interface parameters
spanning-tree Spanning Tree Subsystem
speed Enter the port speed
storm-control Configure Interface storm control
switchport Configure switchport parameters
untagged Default to use for untagged packets on interface
vpc Virtual Port Channel configuration
vtp Enable VTP on this interface
end Go to exec mode
exit Exit from command interpreter
pop Pop mode from stack or restore from name
push Push current mode to stack or save it under name
where Shows the cli context you are in
1,N5K version:
Cisco Nexus Operating System (NX-OS) Software
TAC support: http://www.cisco.com/tac
Documents: http://www.cisco.com/en/US/products/ps9372/tsd_products_support_series_home.html
Copyright (c) 2002-2013, Cisco Systems, Inc. All rights reserved.
The copyrights to certain works contained herein are owned by
other third parties and are used and distributed under license.
Some parts of this software are covered under the GNU Public
License. A copy of the license is available at
http://www.gnu.org/licenses/gpl.html.
Software
BIOS: version 3.6.0
loader: version N/A
kickstart: version 6.0(2)N1(2)
system: version 6.0(2)N1(2)
Power Sequencer Firmware:
Module 1: version v5.0
Microcontroller Firmware: version v1.0.0.2
SFP uC: Module 1: v1.1.0.0
QSFP uC: Module not detected
BIOS compile time: 05/09/2012
kickstart image file is: bootflash:///n5000-uk9-kickstart.6.0.2.N1.2.bin
kickstart compile time: 3/14/2013 1:00:00 [03/14/2013 16:53:55]
system image file is: bootflash:///n5000-uk9.6.0.2.N1.2.bin
system compile time: 3/14/2013 1:00:00 [03/14/2013 19:28:50]
Hardware
cisco Nexus 5596 Chassis ("O2 48X10GE/Modular Supervisor")
Intel(R) Xeon(R) CPU with 8262944 kB of memory.
2,N5K port
Eth102/1/1 -- connected 101 full 1000 --
Eth102/1/2 -- connected 101 full 1000 --
Eth102/1/3 -- connected 101 full 1000 --
Eth102/1/4 -- connected 101 full 1000 --
Eth102/1/5 -- connected 101 full 1000 --
Eth102/1/6 -- connected 101 full 1000 --
Eth102/1/7 -- connected 101 full 1000 --
Eth102/1/8 -- connected 101 full 1000 --
Eth102/1/9 -- connected 101 full 1000 --
Eth102/1/10 -- connected 101 full 1000 --
Eth102/1/11 -- connected 101 full 1000 --
Eth102/1/12 -- connected 101 full 1000 --
Eth102/1/13 -- connected 101 full 1000 --
Eth102/1/14 -- connected 101 full 1000 --
Eth102/1/15 -- connected 104 full 1000 --
Eth102/1/16 -- connected 104 full 1000 --
Eth102/1/17 -- connected 104 full 1000 --
Eth102/1/18 -- connected 104 full 1000 --
Eth102/1/19 -- connected 104 full 1000 --
Eth102/1/20 -- connected 104 full 1000 --
Eth102/1/21 -- connected 104 full 1000 --
Eth102/1/22 -- connected 104 full 1000 --
Eth102/1/23 -- connected 104 full 1000 --
Eth102/1/24 -- connected 104 full 1000 --
Eth102/1/25 -- notconnec 102 auto auto --
Eth102/1/26 -- notconnec 102 auto auto --
Eth102/1/27 -- connected 106 full 1000 --
Eth102/1/28 -- connected 106 full 1000 --
Eth102/1/29 -- connected 104 full 1000 --
Eth102/1/30 -- connected 104 full 1000 --
Eth102/1/31 -- connected 104 full 1000 --
Eth102/1/32 -- connected 104 full 1000 --
Eth102/1/33 -- connected 104 full 1000 --
Eth102/1/34 -- connected 104 full 1000 --
Eth102/1/35 -- connected 104 full 1000 --
Eth102/1/36 -- connected 104 full 1000 --
Eth102/1/37 -- connected 104 full 1000 --
Eth102/1/38 -- connected 104 full 1000 --
Eth102/1/39 -- notconnec 1 auto auto --
Eth102/1/40 -- notconnec 1 auto auto --
Eth102/1/41 -- notconnec 1 auto auto --
Eth102/1/42 -- notconnec 1 auto auto --
Eth102/1/43 -- notconnec 1 auto auto --
Eth102/1/44 -- notconnec 1 auto auto --
Eth102/1/45 -- notconnec 1 auto auto --
Eth102/1/46 -- notconnec 1 auto auto --
Eth102/1/47 -- notconnec 1 auto auto --
Eth102/1/48 ZTC-Switch-48 connected 105 full 100 --
3,Fex
show fex 102 det
FEX: 102 Description: AO4-N2K-FEX102 state: Online
FEX version: 6.0(2)N1(2) [Switch version: 6.0(2)N1(2)]
FEX Interim version: 6.0(2)N1(2)
Switch Interim version: 6.0(2)N1(2)
Extender Serial: FOX1742G09B
Extender Model: N2K-C2248TP-E-1GE, Part No: 73-13671-02
Card Id: 149, Mac Addr: 64:e9:50:16:08:02, Num Macs: 64
Module Sw Gen: 21 [Switch Sw Gen: 21]
post level: complete
Pinning-mode: static Max-links: 1
Fabric port for control traffic: Eth1/3
FCoE Admin: false
FCoE Oper: true
FCoE FEX AA Configured: false
Fabric interface state:
Po102 - Interface Up. State: Active
Eth1/1 - Interface Up. State: Active
Eth1/2 - Interface Up. State: Active
Eth1/3 - Interface Up. State: Active
Eth1/4 - Interface Up. State: Active
Fex Port State Fabric Port
Eth102/1/1 Up Po102
Eth102/1/2 Up Po102
Eth102/1/3 Up Po102
Eth102/1/4 Up Po102
Eth102/1/5 Up Po102
Eth102/1/6 Up Po102
Eth102/1/7 Up Po102
Eth102/1/8 Up Po102
Eth102/1/9 Up Po102
Eth102/1/10 Up Po102
Eth102/1/11 Up Po102
Eth102/1/12 Up Po102
Eth102/1/13 Up Po102
Eth102/1/14 Up Po102
Eth102/1/15 Up Po102
Eth102/1/16 Up Po102show run int eth102/1/25 all
!Command: show running-config interface Ethernet102/1/25 all
!Time: Tue Apr 14 14:33:38 2009
version 6.0(2)N1(2)
interface Ethernet102/1/25
no description
lacp port-priority 32768
lacp rate normal
priority-flow-control mode auto
lldp transmit
lldp receive
no switchport block unicast
no switchport block multicast
no hardware multicast hw-hash
no hardware vethernet mac filtering per-vlan
cdp enable
switchport
switchport mode access
no switchport dot1q ethertype
no switchport priority extend
switchport access vlan 102
spanning-tree port-priority 128
spanning-tree cost auto
spanning-tree link-type auto
spanning-tree port type edge
spanning-tree bpduguard enable
no spanning-tree bpdufilter
speed auto
duplex auto
flowcontrol receive off
flowcontrol send on
no link debounce
no beacon
delay 1
snmp trap link-status
logging event port link-status default
logging event port trunk-status default
mdix auto
storm-control broadcast level 100.00
storm-control multicast level 100.00
storm-control unicast level 100.00
no shutdown lan
load-interval counter 1 30
load-interval counter 2 300
no load-interval counter 3
medium broadcast
channel-group 2025 mode active
no shutdown
show run int eth102/1/48 all
!Command: show running-config interface Ethernet102/1/48 all
!Time: Tue Apr 14 14:35:08 2009
version 6.0(2)N1(2)
interface Ethernet102/1/48
description ZTC-Switch-48
lacp port-priority 32768
lacp rate normal
priority-flow-control mode auto
lldp transmit
lldp receive
no switchport block unicast
no switchport block multicast
no hardware multicast hw-hash
no hardware vethernet mac filtering per-vlan
cdp enable
switchport
switchport mode access
no switchport dot1q ethertype
no switchport priority extend
switchport access vlan 105
spanning-tree port-priority 128
spanning-tree cost auto
spanning-tree link-type auto
spanning-tree port type edge
spanning-tree bpduguard enable
no spanning-tree bpdufilter
speed auto
duplex auto
flowcontrol receive off
flowcontrol send on
no link debounce
no beacon
delay 1
snmp trap link-status
logging event port link-status default
logging event port trunk-status default
mdix auto
storm-control broadcast level 100.00
storm-control multicast level 100.00
storm-control unicast level 100.00
no shutdown lan
load-interval counter 1 30
load-interval counter 2 300
no load-interval counter 3
medium broadcast
no shutdown
Ports are connected, there is no relationship with the speed option, such as port 102/1/1 is connected, but no speed option, port 102/1/47 is notconnected, there speed options.
show int eth102/1/1
Ethernet102/1/1 is up
Belongs to Po2001
Hardware: 100/1000 Ethernet, address: 64e9.5016.0802 (bia 64e9.5016.0802)
MTU 1500 bytes, BW 1000000 Kbit, DLY 10 usec
reliability 255/255, txload 1/255, rxload 1/255
Encapsulation ARPA
Port mode is access
full-duplex, 1000 Mb/s
Beacon is turned off
Input flow-control is off, output flow-control is on
Switchport monitor is off
EtherType is 0x8100
Last link flapped 1d02h
int eth102/1/1
(config-if)# ?
beacon Disable/enable the beacon for an interface
cdp Configure CDP interface parameters
channel-group Configure port channel parameters
description Enter description of maximum 80 characters
inherit Inherit a port-profile
ip Configure IP features
ipv6 Configure IPv6 features
lacp Configure LACP parameters
link Configure link
lldp Configure Interface LLDP parameters
logging Configure logging for interface
mvr-group MVR interface config
mvr-type MVR interface config
mvr-vlan Interface MVR Config
no Negate a command or set its defaults
rate-limit Set packet per second rate limit
service-policy Configure service policy for an interface
service-policy Policy Map
shutdown Enable/disable an interface
snmp Modify SNMP interface parameters
spanning-tree Spanning Tree Subsystem
switchport Configure switchport parameters
untagged Default to use for untagged packets on interface
end Go to exec mode
exit Exit from command interpreter
pop Pop mode from stack or restore from name
push Push current mode to stack or save it under name
where Shows the cli context you are in
show int eth102/1/47
Ethernet102/1/47 is down (Link not connected)
Hardware: 100/1000 Ethernet, address: 64e9.5016.0830 (bia 64e9.5016.0830)
MTU 1500 bytes, BW 0 Kbit, DLY 10 usec
reliability 255/255, txload 1/255, rxload 1/255
Encapsulation ARPA
Port mode is access
auto-duplex, auto-speed
Beacon is turned off
Input flow-control is off, output flow-control is on
Switchport monitor is off
EtherType is 0x8100
int eth102/1/47
(config-if)# ?
bandwidth Set bandwidth informational parameter
beacon Disable/enable the beacon for an interface
cdp Configure CDP interface parameters
channel-group Configure port channel parameters
default Set a command to its defaults
delay Specify interface throughput delay
description Enter description of maximum 80 characters
duplex Enter the port duplex mode
fex Configure FEX fabric
flowcontrol Configure interface flowcontrol
hardware FEX Card type
inherit Inherit a port-profile
ip Configure IP features
ipv6 Configure IPv6 features
lacp Configure LACP parameters
link Configure link
lldp Configure Interface LLDP parameters
load-interval Specify interval for load calculation for an interface
logging Configure logging for interface
mac MAC
mac-address Configure interface mac address
mvr-group MVR interface config
mvr-type MVR interface config
mvr-vlan Interface MVR Config
negotiate Configure link negotiation parameters
no Negate a command or set its defaults
priority-flow-control Enable/Disable PFC
rate-limit Set packet per second rate limit
service-policy Configure service policy for an interface
service-policy Policy Map
shutdown Enable/disable an interface
snmp Modify SNMP interface parameters
spanning-tree Spanning Tree Subsystem
speed Enter the port speed
storm-control Configure Interface storm control
switchport Configure switchport parameters
untagged Default to use for untagged packets on interface
vpc Virtual Port Channel configuration
vtp Enable VTP on this interface
end Go to exec mode
exit Exit from command interpreter
pop Pop mode from stack or restore from name
push Push current mode to stack or save it under name
where Shows the cli context you are in -
If the SSRS is changed to SSL mode and http binding is removed after Reporting Service Point is installed. The Configuration Manager Console shows nothing in Reporting Pane. After digging into this problem, the cause is that the SSRS information has not
been updated in Configuration Manager Database. The following steps are taken for finding the root cause.
1. After changing to SSL, the Reporting Service Point log shows the error as shown in Figure 1.
The request failed with HTTP status 404: Not Found.
(!) SRS not detected as running
Failures reported during periodic health check by the SRS Server DB2.SCJIZHO.COM.
Figure 1
From the error, seems the cause was the Reporting Service Point detected a wrong port. We digged around in Registry and found the information is a Registry key named ReportServerUri at HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\SMS\SRSRP. After changing the Report
Server address to https. The error is gone as shown in Figure 2. But the issue remains, the Console still shows nothing. It is not a right direction.
Figure 2
2. Open the Console log file, it also shows some valuable information.
instance of __ExtendedStatus
Operation = "ExecQuery";
ParameterInfo = "SELECT * FROM SMS_Site WHERE SiteCode = 'PRI'";
ProviderName = "WinMgmt";
\r\n
[1, PID:3136][04/24/2014 01:46:00] :Property: 'LastModifiedTime'\r\nSystem.Management.ManagementException\r\nNot found \r\n at System.Management.ManagementException.ThrowWithExtendedInfo(ManagementStatus errorCode)
at System.Management.PropertyData.RefreshPropertyInfo()
at System.Management.PropertyDataCollection.get_Item(String propertyName)
at Microsoft.ConfigurationManagement.ManagementProvider.WqlQueryEngine.WqlResultObjectBase.get_Item(String name)\r\nManagementException details:
[52, PID:3136][05/11/2014 20:14:15] :[ReportProxy] - User-specified default Reporting Point [PRI.scjizho.com] could not be found, [DB2.scjizho.com] is now the default Reporting Point (Figure 3).
Figure 3
It seems the Console wants to access the old http site and it fails to get into the site for sure. Actually, the Site Configuration information is come from Site Control File and as we all know that ConfigMgr 2012 doesn’t store the Site Control file in the
file system. However, it’s stored in the SQL database (as XML file). The XML file is stored in a view named vSMS_SC_SiteControlXML. This view is a read-only view. We cannot edit it directly. The related table stored the SSRS information for this view is SC_SysResUse_Property.
Running the following query will list the SSRS address. We can see the address is still the old one. This is why the Console shows nothing.
SELECT
name,
value2
FROM dbo.SC_SysResUse_Property
where name
='ReportServerUri'
or name=
'ReportManagerUri'
Remarks:
This article is just to let you know why the Console cannot show the Reports after changing to SSL mode. We do not intend to make you change the table in Database, if you want to change it, you will be at your own risk. The real solution to this situation
is to reinstall your Reporting Service Point.
Please click to vote if the post helps you. This can be beneficial to other community members reading the thread.Ok, but how do you solve this problem? Does uninstalling the RP and adding it back solve this problem?
http://www.enhansoft.com/ -
How do You Make Accurate Speed Changes To Clips?
How do you apply a speed change to an audio clip in with frame accuracy? I have 2 audio clips, one from a camera and the other from a cheap solid-state recorder. The latter has audio drift and needs a one-off, constant adjustment to sync it with the camera audio.
However, FCP only wants to execute clip speed changes down to 1/10th of 1%, which is not small enough. Does anyone know what to do here - either within FCP or Sountrack Pro? Thanks.I just know that often when capturing long segments of DV tape for our shows, we occasionally get a clip that comes in at 47.998 or 48.002, instead of the solid 48kHz.
When I export to aiff, it seems to clear up any sync drifting we experience with the original clips.
Might give it a go.
STPro is a solid option as others pointed out. I simply suggested a quick fix to a possible sync/drift issue. (quicker than learning a new interface...though that's something that should be done anyway, for the tools STPro offers).
K -
Nexus 2248TP port speed and duplexing
Hello Forum Team!
In order to configure the port speed and duplexing (change to 100Mbps/Full-duplex from auto mode) on a Nexus 2248TP interface, does the port needs to be down,.i.e, no link?
Thanks in advanced for your support!Hello and thanks for reply;
I was trying to configure port speed and duplexing on a 2148. This FEX model only works at 1000Mbps as I later found out on the documentation.
Thanks again for your support. -
I just bought an EA2700. The diagnostic says that the WAN port speed is 1 Gigabit. Speedtest however reveals max 85 Mbit throughput which makes me believe that is just Fast Ethernet (100 Mbit). My internet provider delivers 120 Mbit down speed and I would like to get full speed, what is wrong?
This article shows different ways to retrieve your wireless password, raconerz.
-
Compressor encoded speed change clip with echo as motorboat sound
Took me two days to troubleshoot, through trial and error and process of elimination, why Compressor encoded an audio clip that had been speed changed and echo applied to it -- as rapid MOTORBOAT sound! Project is a 5.1 mix. Since STP3 won’t accept speed change clips, after I completed mix in STP I placed speed changed clips on FCP timeline below the exported STP 5.1 mix with the FCP audio tracks for that clip assigned to channels 1 & 2 for the fronts and channels 5 & 6 for the rears. The clip on 5 & 6 was duplicated and identical in every way to the clip on channels 1 & 2. Only the dupe clip on 5 & 6 did Compressor encode as motorboat. The identical clip on 1 & 2 encoded correctly. Both clips were set to play at same time since I wanted the effect to be on fronts and rears simultaneously. I could not get the motorboat sound to play back from either FCP timeline or Compressor preview window. Only after encode and burn to DVD did it show up. Why would Compressor introduce such artifacts on one of the clips and not both – if it’s going to do it at all – which it shouldn’t? Any ideas? I have other such effects throughout the project where I duped a speed changed clip with an effect applied to it and set it to play on fronts and rears simultaneously and Compressor encoded those correctly.
Well, it's a little late, but this is one of the reasons to have your startup drive cloned so you can restore it to a working state if an update, upgrade or install sends things south.
https://discussions.apple.com/docs/DOC-2494
Have you tried resetting your fcp preferences
https://discussions.apple.com/docs/DOC-2491
If this doesn't fix the problem, you could try sending the shot to motion. You could aslo try changing the speed in the motion tab of the viewer. -
IMovie Speed Change.. Again? I know :(
I've been looking some topics about speed change and to do that iMovie has to convert the clip thus this will severely kills the quality of the footage.
But one thing I don't understand is, my camera, NEX-3 records 29.97 fps but even then it needs to be converted. Why is this? As far as I understand, if your footage is in NTSC frame rate, it doesn't need to be converted?
I also did try to do color grading in Adobe After Effects and export it in 30fps in Apple Intermediate Codec, still, it needs to be converted by iMovie before I can alter the speed.
Anyone knows the workaround? Maybe what codec / frame rate that I need to convert it to, before importing it into iMovie? Thanks.Show us a link, please.
Murray --- ICQ 71997575
Adobe Community Expert
(If you *MUST* email me, don't LAUGH when you do so!)
==================
http://www.dreamweavermx-templates.com
- Template Triage!
http://www.projectseven.com/go
- DW FAQs, Tutorials & Resources
http://www.dwfaq.com - DW FAQs,
Tutorials & Resources
http://www.macromedia.com/support/search/
- Macromedia (MM) Technotes
==================
"MelodyTS" <[email protected]> wrote in
message
news:eruq81$ajm$[email protected]..
>
> I have built a 16 page site with DW8 and based on a
template. I made sure
> I
> had all the navigation correct on the template Nav bar
before publishing
> the
> site. Of course the pop up menus work perfectly on my
computer, but all
> the pop
> up links are broken on the server.(can you hear
screaming into the
> night!?!)
> Somebody HELP me! How can I re-do the pop ups with out
having to totally
> re do
> the site? Do I fix it on my local view first then up
load to the server? I
> think the problem might be that the server keeps the
pages in a sub
> folder,
> like /htdocs/page.html, but I can't figgure out were to
change the link
> code to
> point to the pages on the server. ahhhhhhhhhhhh!
> Melody
> -
I am on the cusp of switching to BT from Tiscali / Talk Talk. Until not so long ago both BT and TT showed estimated 26Meg download and BT 10 Meg upload. (Consider I get 3 / 0.8 now) TT were only 2 Meg upload (although they do not publicise this) hence the impending move. However, now both BT and TT show 34 Meg down (Hooray!) but BT has dropped to 6Meg down. I see several posts about speed changes so wondered what was happening? Is this a deliberate switch to give faster download speed at the expense of upload? I know upload speed is less critical for most users inlcuding me, but x5 was a huge difference. x3 is still big but makes the hassle of changing ISPs / email addresses less attractive.
Solved!
Go to Solution.Due to the way the frequency bands are utilised I think that with the recent profile change (from 8c to 17a) some predictions do have a slight reduction in upload but an increase in download. Unless you're a super heavy uploader you won't see that much different between 6meg and 10meg
If you want to say thanks for a helpful answer,please click on the Ratings star on the left-hand side If the the reply answers your question then please mark as ’Mark as Accepted Solution’ -
How to port database changes from development to a production environment
How do I port database changes from the development to the production environment?
I am using v8 and have always had to redo everything using the schema manager all over in the production environment. Is there an easy way to generate a script, for example to dump the database changes on the development machine to be executed later on the production machine?This should already be a clearly defined change control process. Once a procedure, function, package, trigger, or whatever completes the testing rounds, it should be promoted to production.
Forgive me if it seems I'm trivializing, but I don't see the problem, just copy the object(s) from your software library (or development) into production using whatever tool works best or has been chosen. If you are doing data copies then you have various options again including good old export/import. -
How to offset speed change in frame rate conforming?
Hi all. I am conforming video from about 25fps to 30 fps in cinema tools, before editing in FCP. Does any one know of a formula, or calculator tool that would tell me the speed change percentage to use, to get the clip to play in normal speed while editing? Is there a setting to do this automatically in FCP?
And you needn't speed change the footage at all. Simply cutting 25fps footage into a 30fps timeline will do. If you really desire a formula, to convert 25 fps to 30, you need to run it slower (less frames) so the speed is 25/30 or 5/6ths or 83% - to do it the other way, 30/25 = 6/5ths or 120%.
But, like I said, if you cut PAL footage into an NTSC timeline, it will adjust the speed appropriately - sizing too...
Patrick -
Upgrade and plug ins migration ? speed changes and transitions to motion 3
I have the FCS2 upgrade on its way soon i hope..
will my natress plug ins and others migrate when i go from FCS1 to 2?
I am mid project - have done all my captures but havent got into the nitty gritty of the edit yet - you reckon its a bit risky to upgrade?
I am super keen to get the ability to easily do ramps (in Motion 3 or in FC 6) and 3d logo fly arounds. Looking fwd to being able to throw transitions and speed changes into Motion 3 - i hear that it can deal with that now - is this true?Thanks - thats all good
Maybe you are looking for
-
Can the Plug-in Compete?
Why hasn't Java become the dominant technology in RIA development? I'm not the first person to ask this question, nor will I be the last. It is unbelievable to me that the company that invented the RIA over a decade ago has made little or no progress
-
When creating an event in iOS 7 calendar, the event editing box has a really choppy scroll animation (or whatever it is). However, if my iPad switches to landscape/ switches to landscape and back to portrait view, the scroll lag goes away. Any soluti
-
Windows 7 hangs from boot menu
Hi, my Windows 7 partition refuses to start from boot menu, system just hangs and does nothing. I've not made any changes to the disk layout, only thing I can think of is the upgrade to 10.9.4 which probably changed the recovery partition. History: -
-
Search Engine Toolbar inactive - will not search when enter pressed
I recently upgrade to Firefox 5 from Firefox 3.6. The Search toolbar worked great in 3.6 but now in 5 when I type into the search engine I get suggested results but when I hit "enter" to perform the search nothing happens. I tried to switch different
-
I need another way to access my songs.
After an itunes update last spring I was never able to get itunes to work on my PC again. Now I'm having issues on my laptop after an itunes update this week. I will need to un-install itunes from the laptop to troubleshoot the issues. Where can I