Os x maverick and Labview 2012

Do have anybody experience with Labview 2012 under OS X Maverick? Is it any trouble after update from Mountain Lion (10.8.5) to Maverick with Labview 2012?
Solved!
Go to Solution.

Hi Vitko,
Maverick is at this point regretfully not supported.
That being said - it might work - it really depends on what changes did Apple did to the kernel in the meantime.
Maybe some of the forum users have hands on experience that they can share about trying this combination.
Best regards,
Jano

Similar Messages

  • Again mixed signal graph and Labview 2012

    I have just experienced a weird change in labview 2012 on the mixed signal graphs. In a preliminary analysis, it seems that the most critical behavior is related to the silver mixed signal graph, although i didn't have the time to test the standard one.
    Straight to the point... the property "plot area size" not only resizes the plot area, but also the graph; this is in contrast with what happened previously in LV2011. If the graph belongs to a subpane and if the property "fit control to pane" is enabled, the area resize prevents the graph from correctly fitting the pane. 
    Any suggestion?
    cheers
    m.
    Attachments:
    MixedSignalDisaster.vi ‏13 KB

    I think that since this behavior is a regression (working properly until LabVIEW 2011 SP1) this should be fixed as soon as possible through a specific fix, without waiting for the next Service Pack.
    This regression has been blocking the development of our application.
    Could someone from the NI support give an answer, please?
    Vix
    In claris non fit interpretatio
    Using LV 2013 SP1 on Win 7 64bit
    Using LV 8.2.1 on WinXP SP3
    Using CVI 2012 SP1 on Win 7 64bit, WinXP and WinXP Embedded
    Using CVI 6.0 on Win2k, WinXP and WinXP Embedded

  • Installing both Vision Builder 2012 and LabView 2012 on same Computer

    am new to NI Vision Builder Automation Inspection 2012 (Which I am supposed to learn and use for part inspection) as well as LabView (Which I need not know at this time)
    When I was presented (to work with) a 1722 Camera and the computer, Labview 2012 was already installed but not Vision Builder.
    The IT folks installed the Vision builder without uninstalling LabView.
    I have my problems getting upto speed with my inspection work, but is any of it attributed to both systems being on the computer?
    Can I (Must I) uninstall LaView??
    Thanks

    LabVIEW and Vision Builder run fine on the same computer.  I have several versions of each on mine with no problems.
    Bruce
    Bruce Ammons
    Ammons Engineering

  • Report Generation Toolkit Compatibility with Microsoft Office 2013 and LabVIEW 2012

    Hello community,
    on this page there is shown the Report Generation Toolkit Compatibility with Microsoft Office and LabVIEW.
    In our company we use actually LabView 2012 and it works perfectly with MS Office 2010.
    Has anyone ever tried the "Report Generation Toolkit" of LabVIEW 2012 with MS Office 2013? Does it really not work? Has anyone an emirical value for this topic?

    Hi digital_badger,
    as you sure have seen in the link it is not officially supported by NI, which means to you one of the following things:
    1. You could upgrade your LabVIEW and your Report Gerneration Toolkit to Version 2014 and use MS Office 2013
    2. You could just try it with MS Office 2013 which might work but if it's not working you don't get any support from NI.
    Even if someone tried it already and it worked for him does not mean that it will work on your machines. It is possible that on some of your machines it could work but not on others. Their can be a lot of problems while playing around with unsupported setups.
    3. You could leave your setup as it is and stick to your MS Office 2010.
    I hope I could give you a good answer to your question

  • Is Labview 2012 run-time on TPC-2206?

    When I go to Uninstall programs on my TPC-2206 I see Labview Run-Time 2009, 2010 and 2011. Labview 2012 Run-Time does not show up in the list. When I download and install it, I still only see the above plus a generic National Instruments program. The new TPC-2206 touch panels we have show a generic National Instruments program in the program list, but I don't know how to find out if that is Labview 2012 Run-Time. I can't find anywhere on the NI website that lists what Run-Time software is already loaded on the Touch Panels.

    I did try running a Labview 2012 executable after I had put up the post. It did not work, so I knew that Labview 2012 Run-Time was not on it. I put Labview 2012 Run-Time on it, but afterwards when I looked in the Remove/Change programs list in the Control Panel, Labview 2012 Run-Time was not in the list of installed programs. There was a generic National Instruments program, but there was nothing identifying what NI program it was. This was the real problem, because all of the earlier versions of Labview Run-Time were clearly identified in the installed programs list and Labview 2012 Run-Time was not. There is no way to know if Labview 2012 Run-Time is installed except to try to run a Labview 2012 executable.

  • Driver NI PXIe 5641r for Labview 2012

    hi. i have module NI PXIe 5641r and labview 2012, i installed driver NI PXIe 5641r; however this driver did not support labview 2012 softwave. help me please!

    Hello!
    You should be able to download the PXIe-5640R 1.7 to work with your PXIe-5641R. Here is a link to that driver:
    http://www.ni.com/download/ni-5640r-1.7/4371/en/
    According to the readme, this will work with a PXIe-5641R as well as 32-bit LabVIEW 2012. Hopefully this helps!
    Thanks,
    Stephanie S.
    Application Engineer
    National Instruments

  • Can I get MJD (date and time) in LabVIEW 2012 SP1?

    I need to time stamp my data before sending it to the file.  I have been doing this with the standard calendar date and time but MJD is what we prefer to use.  How can I get an MJD timestamp in LabVIEW 2012 SP1?
    Solved!
    Go to Solution.

    Hello Brad_Henry,
    The Format Date/Time String will return the day of the year when the %j argument is used, as per this help document:
    LabVIEW Help: Format Codes for the Time Format String
    http://zone.ni.com/reference/en-XX/help/371361J-01/glang/codes_for_time_format_str/
    If you're looking for the actual MJD, I'm not aware of a built-in function that generates this so you'll probably need to create or find a function to calculate it manually.  This should pretty basic arithmetic, and it looks like people have already made a few public examples, the first two search results here look to be just about what you need:
    ni.com search:
    http://search.ni.com/nisearch/app/main/p/bot/no/ap/tech/lang/en/pg/1/sn/catnav:ex/q/julian/
    Regards,
    Tom L.

  • Compatibility of LabView 2012 installed on XP with Vision and Trad DAQ

    Is LabView 2012 runnung under Windows XP compatible with
    A: NI Vision 2011 ? 
    B: Traditional DAQ 7.4.4 ?

    This should answer your question:
    Windows Version Compatibility with LabVIEW
    Compatible Versions of Vision Development Module with LabVIEW and LabWindows/CVI
    NI-IMAQ, NI-IMAQdx, NI-IMAQ I/O, and VAS Compatibility with Different LabVIEW Versions
    NI-DAQ and LabVIEW Version Compatibility (for Windows)
    I would still suggest to have a look at the readme files as well.
    Adnan Zafar
    Certified LabVIEW Architect
    Coleman Technologies

  • Upgraded my macbook pro 2012 to osx mavericks and since then I'm having troubles like: can't open mail or maps. recently if I'm trying to fill a onfo box from a web site safari stops working.

    upgraded my macbook pro 2012 to osx mavericks and since then I'm having troubles like: can't open mail or maps. recently if I'm trying to fill a info box from a web site safari stops working.

    Try backing up your data and upgrading to 10.9.2.

  • Labview 2012 (64bit) not working with ActiveX and MSAccess

    I have a program developed to open a MSAccess database file and import data using ActiveX commands. The program works with LabView 2012 (32bit) but fails on the ActiveX open command when using LabView 2012 (64bit). I also have the application built as an EXE and it works fine in a windows 32 bit environment (XP or Win 7-32bit) but fails when run on Win 7-64bit. I isolated the error down to the Active X automation Open VI.
    Anyone have a solution for the incompatibility?
    summary
    1.) VI and EXE works on XP and Win 7-32bit
    2.) EXE fail on Win 7-64bit.
    3.) VI works on Win 7-64 bit with LV 2012 (32bit)
    4.) VI fails on Win 7-64 bit with LV 2012 (64bit)

    It looks like you are trying to load a 32-bit DLL from a 64-bit OS. Do you have a 64-bit version of access installed? You'll need to change to that. On the other hand, ActiveX with Access is so slow. You can speed things up considerably by using ADO (i.e. NI's Database Connectivity Toolkit or something like LabSQL).

  • LAbVIEW 2012 and Solidworks Examples update

    Hi,
    I noticed that the examples shipped with NI Softmotion module is not updated (SoftMotion>Mechatronics). Although the directory has been changed, the example still points to LabVIEW 2009 folder. I also would like to ask whether these examples was tested with LabVIEW 2012 as it doesn't run with my machine which has LabVIEW 2012 and Solidworks 2010 SP4.
    Your help is much appreciated.
    P.S: I apologize for double posting since no single reply was mentioned on Motion forum.
    Waleed El-Badry MSc.,MCPD, ISTQB Certified Tester
    Assistant Lecturer
    Mechatronics Department
    Faculty of Engineering
    Misr University for Science & Technology

    The problem seems to be with Scan Engine.
    Here is a screenshot of the error mesage when deployment:
    Configuration:
    OS: Windows 8 Final
    LabVIEW Version: 2012 with all updates installed
    NI SoftMotion Version: 2012
    Solidworks Version: 2010 SP4 
    I doubt the problem lies in OS as all examples are running flawlessly except that with Mechatronics Examples. Hope to get any response from NI SoftMotion Team. Thanks for your assistance in advance.
    Waleed El-Badry MSc.,MCPD, ISTQB Certified Tester
    Assistant Lecturer
    Mechatronics Department
    Faculty of Engineering
    Misr University for Science & Technology

  • I just downloaded Mavericks and now my AutoCAD 2012 won't open. What do I do?

    I just downloaded Mavericks and now my AutoCAD 2012 won't open. What do I do?

    Autocad 2012 is NOT Mavericks compatble.
    So, you either need to find and pay for an upgrade AutoCad 2013 which is compatible with OS X Mavericks or pay to upgrade to AutoCad 2014.
    If you have a cloned backup of your previous system before upgrading to Mavericks, it would have been easy to revert back to your previous OS X version.
    If you don't have a previous backup, your only option, now, is to create a backup of your system and important data , now, to an external hard drive. Once you have a backup, you need to purchase and clean install OS X 10.8 Mountain Lion (if you haven't purchase Mt. Lion already).
    http://store.apple.com/us/product/D6377Z/A/os-x-mountain-lion
    AutoCad 2012 is compatble with OS X 10.8. You'll have to reinstall all of your applications including AutoCad.

  • LabVIEW 2012 and LegoNXT

    Hi,
    Will my EV3 Lego mindstorm brick work with LabVIEW 2012 and LabVIEW Lego MindstormNXT 2012? Because when I'm installing LabVIEW module for Lego 2012, it'sprompting me to install LV2012 SP1. I already have LV2012 but NOT SP1. 
    Regards.

    NapDynamite wrote:
    The system in my lab has no SP1, probably the guy over here never bothered to install that update. Now when I checked those updates to install SP1, the update service is locked for this patch and is asking for renewal of subscription.
    My boss, who is not very cognizant of software stuff, is now asking me to use the EV3 software which comes along with LEGO pack becuase he's not ready to spend much to renew.
    And my dream of teaching LabVIEW to school kids is now in vain.
    Regards. 
    In vain?
    A bit dramatic isn't it?
    One license is $99.
    Site license is $570.
    http://sine.ni.com/nips/cds/view/p/lang/en/nid/210666

  • LABVIEW 2012 - shared variable error during programming of NI CRIO 9023 and TPC 2212

    HELLO,
    i am using CRIO 9023 with TPC 2212 and LV 2012. I want to develop a stand alone app which has a front panel on TPC. at first i am building a simple app with two controls variables, one is a sliding bar on TPC Vi and the other one is the while loop  variable "i" on CRIO VI. i used  shared variables.
    first i creat shared variable on CRIO side and access this on TPC Vi. I COMPILE both Vi,s and they are working fine. But when i created the slide bar control in TPC VI, compiled and deploy the TPC Vi, it get deployed in TPC. But when i  start compiling the CRIO VI an error mesage occured as follows;
    I have tried every option to best of my understanding like formating crio then installing all softwares including Network variable engine etc. i also go in properties of the executable file of TPC Vi and go in properties-shared variable- then check the "deploy variable in application" option . below is image displayed.
    I am in despirate need for solving this problem as i have to develop the final app for testing soon. can some one help me regrarding this.
    REGARDS

    I would not recommend using shared variable engine.  It is supposed to make things easier, but in fact, you will spend more time troubleshooting why it is not working than you will actually coding an alternative solution.
    Try the Simple TCP Messaging instead.
    http://zone.ni.com/devzone/cda/epd/p/id/2739
    Machine Vision, Robotics, Embedded Systems, Surveillance
    www.movimed.com - Custom Imaging Solutions

  • Some fonts are not shown correctly in LabVIEW 2012

    I found a bug related with fonts in LabVIEW2012 f3 KR.
    - When I select NI7SEG in font selection dialog, right font is not shown in the example box.
    - Draw text at point.vi shows same problem for some fonts while other fonts are working.
    I reported it to Korean NI. As far as I know, this was not reported in previous versions and I couldn't find any related documents in Google. 
    So, here I would like to know whether it is related with only Korean version. Please let me know if English version is OK. 
    * OS: Windows 7 32bit KR

    Just now, I installed LabVIEW 2012 f3 (32-bit, English) and checked for the issue. But the font(NI7SEG) was not shown properly in VI either.
    - Both of Korea and English version of LabVIEW 2012 on Win 7 Korea OS shows wrong results. It is same on 64-bit OS.
    - LabVIEW 2010 but on same PC shows correct fonts.
    Is there a limit of number of fonts in LabVIEW? There are more than 100 fonts are shown in the "Selection Font" dialog and I can divide them into 3 groups by sequential order. I find that all fonts in the 3rd group are not applied correctly.
    (1st group)
    Arial Unicode MS...
    Bookshelf Symbol 3....
    Windings 3
    (2nd group)
    @Arial Unicode MS...
    @Terminal
    (3rd group)
    Arial...
    Consolas...
    Courier...  
    Licida Console... 
    NI7SEG...
    Verdana

Maybe you are looking for

  • Error: The result is empty for XPath expression

    hi gurus Following is my input sample data to BPEL process. <ItemList> <Item> <Name>Music System</Name> <Id>525</Id> <Item> <Name>Fog Light</Name> <Id>325</Id> <Item> <Name>Tyres</Name> <Id>325</Id> <Item> <Name>Neon Light Ring</Name> <Id>325</Id> </

  • Exception in XMLIsValid function

    Hi anybody can you help me in providing the actual error whic i am geetiing while validating the xml with xsd by using XMLIsValid  function

  • Server-side Trust with CryptoLib &/or 3rd party tool

    I have a new installtion: > BOE XI 3.1 SP2 (Solaris) > SAP Integration Kit Intend to enable server-side trust / SNC betw BOE and BW. Separately, BASIS just installed/config'd new standard tool (Quest's Vintela) on BW for SSO from SAP GUI clients to B

  • Print  XMP File Info?

    Hello - Anyone know if there's a way (a relatively easy way) to include certain fields from XMP File Info in a printout? Specificaly, I'm trying to do this from Illustrator CS. Thanks, John

  • 0IC_C03 material stock and movement

    Hi Experts, I posted this issue before.  I did not get any response.  My co-worker and I opened several messages with SAP, we could not get any meaningful answer either.  Now, I'd like to give it one more try.  I truely believe that with all the expe