OSPF equal cost - loops

Hi
Please see attached diagram.
When I traceroute from the Cisco 892 router (on the top) to an 10.31.48.0 address the packages is looped between the two cisco 2821 routers two times before the package is delivered.
Type escape sequence to abort.
Tracing the route to 10.31.48.2
VRF info: (vrf in name/id, vrf out name/id)
  1 172.20.1.2 0 msec
    172.20.1.1 0 msec
    172.20.1.2 0 msec
  2 10.31.45.2 12 msec
    10.31.45.7 4 msec
    10.31.45.2 4 msec
The package should go from the 172.20.1.2 directly to 10.31.45.2 or 10.31.45.7 and then to the end host. The traceroute shows that the package is bounced two times.
Any suggestions?
Best Regards, Steffen.

If it was a loop, your ping would not work. The output you get is as a result of the probes used in a traceroute. This link seems to give a reasonable explanation:http://www.dasblinkenlichten.com/why-does-my-traceroute-look-like-that/
Just so you can see, run an extended ping on the 892 like below and share output here.
Cisco-892#ping
Protocol [ip]:
Target IP address: 10.31.48.1
Repeat count [5]:
Datagram size [100]:
Timeout in seconds [2]:
Extended commands [n]: y
Source address or interface:
Type of service [0]:
Set DF bit in IP header? [no]:
Validate reply data? [no]:
Data pattern [0xABCD]:
Loose, Strict, Record, Timestamp, Verbose[none]: r
Number of hops [ 9 ]: 3
Loose, Strict, Record, Timestamp, Verbose[RV]:
Sweep range of sizes [n]:

Similar Messages

  • Nexus 7010 OSPF Equal Cost Paths

    Hello,
    I currently have two physical links connecting one data center to another.  These are both 10Gb links and I have manually set the cost to the primary link to '1' and the secondary link to '10'.  My question is, if I set the secondary link to '1' they would have equal cost routes.  What is the selection process at this point?   Will equal cost load balancing automatically kick in and use both links?
    Thank you,
    Scott

    Scott
    Haven't used Nexus switches but generally yes it should do depending on the routing protocol ie. statics, EIGRP, OSPF etc. will use equal cost paths if they are in the routing table.
    BGP is different in that without further configuration it picks just one path so there is only one entry in the routing table.
    By default it will use per destination load sharing and the default on Nexus is destination IP address and port number to choose which link to use.
    "sh ip load-sharing"
    will show you the current method it is using.
    Jon

  • OSPF Equal Cost (multiple links) but unbalanced traffic

    Hi!
    I would like to ask about OSPF.
    We are using 4 links running OSPF point to point with equal cost to load balance MPLS L2 traffic between our two routers.
    And from what we are experiencing right now is that it didnt balance the load the way it should have.
    The first link always catches up the bulk of the traffic, while the remaining 3 links load balances, I would like to inquire on steps to mitigate the issue.
    Appreciate if I could receive some help to solve the issue
    Thank you very much  in advance!
    Best Regards,
    asakurahao

    I do have almost the same problem.
    i have 2 x 20 Mbps Point to Point ethernet links configured with equal ospf cost and both links terminated on the single router at both ends.
    interface FastEthernet0/0/0
     bandwidth 20000
     ip address x.x.x.x y.y.y.y
     load-interval 30
     duplex auto
     speed auto
     traffic-shape rate 20000000 500000 500000 1000
    interface FastEthernet0/0/1
     bandwidth 20000
     ip address x.x.x.x y.y.y.y
     load-interval 30
     duplex auto
     speed auto
     traffic-shape rate 20000000 500000 500000 1000
    FastEthernet0/0/0 is up, line protocol is up
      Internet Address 135.254.193.53/30, Area 0.0.0.1
      Process ID 3435, Router ID 135.254.0.95, Network Type BROADCAST, Cost: 5
    FastEthernet0/0/1 is up, line protocol is up
      Internet Address 135.254.193.45/30, Area 0.0.0.1
      Process ID 3435, Router ID 135.254.0.95, Network Type BROADCAST, Cost: 5
    I see majority of the traffic using the link F0/0/0 and only 30% traffic using the second link F0/0/1.
    I used per-packet load-sharing on these interfaces which caused throughput problems, so i removed that from the interface. Should i add some CEF commands or should try per-destination load sharing to see equal traffic on both links ?

  • OSPF equal cost path

    Hi all,
    I have
    The network 192.168.0.0 is directly connected to Router A and B. Router A and B are redistributing the network in the ospf area 0.
    Router A,B,C,D belong to the same OSPF Area.
    Router C is DR. The cost of the link is indicated in the draw.
    Question:
    Router D (and router C) is using as next hop the Router A for reaching the network 192.168.0.0.
    Why the router D is not using the router B as next hop due to the fact that all the possible paths are equal cost?
    Thanks.

    Hi,
    At the end the information provided by Rolf fit in my case.
    Playing with the cost to reach the ASBR and the metric of the external route I was able to figure out why the router A is the50
    preferred exit point: during the redistribution router A is modifying the metric value, in this way C and D are using A as
    Thanks all!!!

  • OSPF Equal Cost Path Selection

    This is a nerdy enough qeury in reality.
    We have a single area - area 0.0.0.32. All intra-area routes. We have 2 switches in the core of the network, and 10 switches at the edge. All of these switches are connected via layer 3 OSPF routed links.
    The cost for all links is 20 - which is based on bandwidth between the boxes - which is 2Gbps.
    Have a look at the enclosed jpeg to get an idea.
    Very simple.
    Query revolves around the path selection available to OSPF.
    The path from Core 2 to the 10.32.51.0 network is easy - straight across the link between the core switches for a cost of 20.
    Question :- if the link between the cores fail, which path will be chosen by OSPF and why?
    It can go through ANY of the other edge switches for a total cost of 40, but it will choose a particular one. What criteria does OSPF use to select this path?
    Remember, the path costs are equal, they are all intra-area.
    I tried messing with Router ID, but this doesn't seem to be it.
    I tried highest interface IP addresses, but it doesn't seem to be this.
    It is not a random act, the algorithm chooses the same one every time.
    There must be some parameter in the LSDB that is the defining one when it comes to path selection.
    Can you help me out please. I need someone who understands the OSPF algorithm better than I do (which might not be hard!).
    Appreciate any comments for debate.

    Disclaimer
    The  Author of this posting offers the information contained within this  posting without consideration and with the reader's understanding that  there's no implied or expressed suitability or fitness for any purpose.  Information provided is for informational purposes only and should not  be construed as rendering professional advice of any kind. Usage of this  posting's information is solely at reader's own risk.
    Liability Disclaimer
    In  no event shall Author be liable for any damages whatsoever (including,  without limitation, damages for loss of use, data or profit) arising out  of the use or inability to use the posting's information even if Author  has been advised of the possibility of such damage.
    Posting
    My guess (as I haven't re-read the RFC), selection of an ECMP to retain in a routing table (assuming all possible ECMP are not retained) and/or exactly how packets or flows are ECMP routed is implementation dependent.
    I recall years ago bumping into a situation where I had 6 (OSPF) ECMP on a Cisco router which had the (then) default allowance of 4 ECMP in the route table.  I don't recall exactly what the issue was, but whatever it was doing I considered it a bug.  The "fix" was to allow the router to use all 6 ECMP.  (Again, don't remember the specifics, but the issue I saw was more involved than 2 of the 6 ECMPs weren't retained.)

  • If equal cost routes exist, OSPF uses CEF load balancing?

    Hi All,
    Can anyone explain about:
    . If equal cost routes exist, OSPF uses CEF load balancing?

    Disclaimer
    The Author of this posting offers the information contained within this posting without consideration and with the reader's understanding that there's no implied or expressed suitability or fitness for any purpose. Information provided is for informational purposes only and should not be construed as rendering professional advice of any kind. Usage of this posting's information is solely at reader's own risk.
    Liability Disclaimer
    In no event shall Author be liable for any damages whatsoever (including, without limitation, damages for loss of use, data or profit) arising out of the use or inability to use the posting's information even if Author has been advised of the possibility of such damage.
    Posting
    Rick is correct, but if his response, with mine, causes any confusion. . .
    To OP's original question:
    If equal cost routes exist, OSPF uses CEF load balancing?
    The answer is technically no, for the reason Rick describes.
    But if we rephrase, such as:
    Does CEF load balance across multiple equal cost routes generated by OSPF?
    The answer would be yes.
    I suspect the latter question is what the OP really had in mind, but again, Rick is correct to distinguish that OSPF doesn't use CEF.

  • ECMP - equal cost multi path

    Hi,
    What is the concept behind ECMP  (equal cost multi path) ? Is it different for EIGRP , OSPF , ISIS etc ?
    thanks

    Disclaimer
    The Author of this posting offers the information contained within this posting without consideration and with the reader's understanding that there's no implied or expressed suitability or fitness for any purpose. Information provided is for informational purposes only and should not be construed as rendering professional advice of any kind. Usage of this posting's information is solely at reader's own risk.
    Liability Disclaimer
    In no event shall Author be liable for any damages whatsoever (including, without limitation, damages for loss of use, data or profit) arising out of the use or inability to use the posting's information even if Author has been advised of the possibility of such damage.
    Posting
    The concept behind ECMP is to actively and concurrently take advantage of multiple link/path bandwidth.
    Oh, and to just add to what Jon has already noted, ECMP usually doesn't track actual load.  So, "seeing" unequal path/link loading, especially short term, isn't unusual.
    PS:
    There's also unequal cost multi-path routing too - EIGRP supports that.

  • IS-IS and IPv6 in equal cost path topology

    Network of 7609s running 12.2(18)SXE3. Two
    equal cost path links between each 7609. IS-IS Level 2 routers only. When pinging an off campus IPv6 host every other packet is lost. It seems like the equal cost paths prevent an alternative path off campus but that path isn't working.
    We cannot figure out where to look next.
    Any thoughts ? Is this possibly an IS-IS
    issue ?
    Thanks

    OK. I'll try. We have 5-7609s running 12.2(18)SXE3.
    Each 7609 has a variety of 100/1000Base Ethernet
    interfaces. They each also have one WS-X6704-10GE out
    of which connections to our primary and secondary
    backbones originate. This is how the routers are
    interconnected.
    Three of the five core routers are currently running
    IS-IS. If we ssh into any router and ping
    www.netbsd.org every other packet is lost.
    At the end of the network are two 6506 switches each
    with a 10GE module and a 1GE module.
    Attached to the 1GE module are fiber links two
    two different Juniper M10s which also run IS-IS
    and through which we get upstream connectivity
    to our provider.
    All of our routers are level 2 routers in the same area.
    Does this help? If not please let me know what else
    you would need.
    Thanks,Steve

  • EIGRP- Equal Cost Paths Selection

    Hello,
    This might be a simple question; using EIGRP and having 2 equal cost paths to the destination; how does the router/L3 switch route select the path from those two equal cost paths? Is there a way to force one path over anthoer?
    Thanks in advance.
    Best, ~sK       

    To answer your question we need to be clear that there are 2 parts to the decision about which path will be used to forward traffic. The first part is the identification of paths and their insertion into the routing table. This is the part where EIGRP plays a role. If EIGRP determines that there are two equal cost viable paths then both of the paths will be put into the routing table. This ends EIGRP involvement in the process. The part of the process that takes a particular packet and determines which path to use is handled by CEF. By default CEF looks at the number of available paths toward a destination and when there are multiple paths CEF will use a process that calculates based on source and destination address to choose a particular path. For the same source address and same destination address CEF should choose the same path every time.
    HTH
    Rick

  • RIP/EIGRP maximum number of Equal cost routes

    I am looking for documentation on:
    If a router has 20 equal cost routing paths and only 4 show up in the routing table, what is the determining factor that chooses which four and where are the other 16 put in case the 4 routes become unusable.
    Most documentation will tell you the maximum amount and how to change it but I have not found any documentation on how EIGRP or RIP chooses the routes.

    You can have up to 4 by default, but you can configure the routing table to accept up to 6 on older code, and up to 8 on newer code, using the command "maximum-paths" under router eigrp. EIGRP will attempt to install all of the available paths, but the routing table will only allow it to install the first x that it installs.
    The routes which are not installed by EIGRP are placed in a "backup table." If one route fails, each routing protocol running on the router is notified, and will attempt to install any routes (which match the destination, of course) back into the routing table. Again, the frst x paths would win.
    Be careful with this much redundancy in eigrp--you're playing with fire if you have 15 or 20 links between a pair of routers.Russ

  • 2 locations, 2 core switch stacks, fibre in between, equal cost load balancing between?

    Hi,
    We've recently inherited a job that another company was doing, so we've had our hand slightly forced on the kit and overall topology involved, however that's all fine and we can make it work.
    This is a collapsed core topology with core and access switches, split over 3 blocks (fibre connections between), one core switch/stack is in block B and the other in block C, with access switches throughout.
    They require all access switches to be connected to the Core in B and the Core in C, and then obviously cross connects between the two cores.
    They state:
    "Core switches shall be linked with 2x 1Gbps links bonded into a standard compliant Etherchannel"
    "Uplinks between access and core switches shall be non-blocking - for example equal cost load balancing at layer 3, or layer 2 bonded multi-chassis Etherchannel"
    The specced kit for the core are 3850's, in an ideal world I'd use VSS (Virtual Switch System) to achieve the above statements beyond repute; but this is only supported on 4500/6500 and Nexus platforms.
    Do we think a cross stack etherchannel (LACP between both core switch stacks) would satisfy the above statements? Or the statements may just be badly worded...
    I look forward to your thoughts and views on this! Thanks!

    Disclaimer
    The Author of this posting offers the information contained within this posting without consideration and with the reader's understanding that there's no implied or expressed suitability or fitness for any purpose. Information provided is for informational purposes only and should not be construed as rendering professional advice of any kind. Usage of this posting's information is solely at reader's own risk.
    Liability Disclaimer
    In no event shall Author be liable for any damages whatsoever (including, without limitation, damages for loss of use, data or profit) arising out of the use or inability to use the posting's information even if Author has been advised of the possibility of such damage.
    Posting
    As the others have noted, the 3850s, to stack, are restricted to the length of the longest stack cables.
    As you have noted, VSS physical units would allow the "logical" unit to be far apart.
    For a "small" VSS core, the 4500-X might be an idea unit.  (Other than cost, the 4500 would be a better choice for a core device.)
    Something to watch for, or understand, when running VSS, Etherchannel doesn't load balance as it does on a single chassis or stack.  VSS will avoid using the VSL cross link unless it must.
    As many access switches, today, support basic L3 routing, you might also determine whether a L3 edge would be a suitable alternative choice.  It would allow retention of the 3850s and can offer some advantages even over VSS.  (Where VSS is very nice [as too the Nexus] supporting servers with Etherchannels.)

  • How to use equals in loop of an Stored Procedure

    Hi ,
    This is my Stored Procedure which is working fine (mean displaying all the Data from the Table)
    Here i want to add this functionality that is i want to check if there is 'IND' in country_code , i want to throw an Exception manually .
    I am struck up here : After the cursor fetches all the country_code in its loop , how can i check the whether country_code contains 'IND' or not in it ??
    create or replace PROCEDURE Auto_After_Bod_Status
    is
    country_code    VARCHAR2(40);
    myException EXCEPTION ;
    CURSOR PD1
    IS
    SELECT COUNTRY_CODE FROM LINK_STATUS;
    BEGIN
    OPEN PD1;
    LOOP
    FETCH PD1 INTO country_code;
    DBMS_OUTPUT.PUT_LINE(country_code);
    EXIT WHEN PD1%NOTFOUND;
    END LOOP;
    CLOSE PD1;
    END  Auto_After_Bod_Status;
    please help .Thanks .

    user10503747 wrote:
    I am struck up here : After the cursor fetches all the country_code in its loop , how can i check the whether country_code contains 'IND' or not in it ??Why do you need to check it after the loop. Check as soon as row is fetched. Also, your DBMS_OUTPUT.PUT_LINE(country_code); should be after EXIT WHEN PD1%NOTFOUND; not before:
    create or replace PROCEDURE Auto_After_Bod_Status
    is
    country_code VARCHAR2(40);
    myException EXCEPTION ;
    CURSOR PD1
    IS
    SELECT COUNTRY_CODE FROM LINK_STATUS;
    BEGIN
    OPEN PD1;
    LOOP
    FETCH PD1 INTO country_code;
    EXIT WHEN PD1%NOTFOUND;
    DBMS_OUTPUT.PUT_LINE(country_code);
    IF country_code LIKE '%IND%'
      THEN close pd1;
           raise myException;
    END IF;
    END LOOP;
    CLOSE PD1;
    END Auto_After_Bod_Status;But if you want to fetch all rows first:
    create or replace PROCEDURE Auto_After_Bod_Status
    is
    country_code VARCHAR2(40);
    ind number := 0;
    myException EXCEPTION ;
    CURSOR PD1
    IS
    SELECT COUNTRY_CODE FROM LINK_STATUS;
    BEGIN
    OPEN PD1;
    LOOP
    FETCH PD1 INTO country_code;
    EXIT WHEN PD1%NOTFOUND;
    DBMS_OUTPUT.PUT_LINE(country_code);
    IF country_code LIKE '%IND%'
      THEN ind := 1;
    END IF;
    END LOOP;
    CLOSE PD1;
    IF ind = 1
      THEN raise myException;
    END IF;
    END Auto_After_Bod_Status;SY.

  • Load balancing by equal cost Static Routes

    Hello All,
    I have 2 WAN links for Internet connectivity and I want to load balance IP traffic on both links. If I use 2 default routes like this,
    ip route 0.0.0.0 0.0.0.0 serial 0
    ip route 0.0.0.0 0.0.0.0 serial 1
    then its enough to achieve load balancing or I have to configure following interface configuration command.
    (config-int)# ip load-sharing per-packet
    Kindly advice.
    Regards,
    Mujeeb

    hi ankurbhasin. I have one doubt pertaining to per-packet load-sharing. In order to connect my two remote sites- A & B, Site A is having two WAN links and Site B is having two WAN links - one from ISP1 (30Mbps link) and the other from ISP2 (50Mbps link). I am doing static route load balancing using same AD values for both the ISPs. I have configured "ip load-sharing per-packet" on both the outgoing interfaces.
    The load is getting distributed equally across both the links but total bandwidth utilization across both the links is not going beyond 30Mbps. The combined bandwidth of both links is 80Mbps (50+30). However links are not getting fully utilized even though heavy load is there on the links. Can you please tell me how to make full use of both the wan links at both the ends?

  • Equal Cost Multi Path route support.

    Can anyone tell me if Solaris 8 supports ECMP? First if it works, and second, if it officially works?
    Anyone have a web page or document stating it works?
    Even more generally, can anyone point me to a Sun web page that lists RFC compliance for their OS's?
    Thanks in advance!

    Disclaimer
    The Author of this posting offers the information contained within this posting without consideration and with the reader's understanding that there's no implied or expressed suitability or fitness for any purpose. Information provided is for informational purposes only and should not be construed as rendering professional advice of any kind. Usage of this posting's information is solely at reader's own risk.
    Liability Disclaimer
    In no event shall Author be liable for any damages whatsoever (including, without limitation, damages for loss of use, data or profit) arising out of the use or inability to use the posting's information even if Author has been advised of the possibility of such damage.
    Posting
    The concept behind ECMP is to actively and concurrently take advantage of multiple link/path bandwidth.
    Oh, and to just add to what Jon has already noted, ECMP usually doesn't track actual load.  So, "seeing" unequal path/link loading, especially short term, isn't unusual.
    PS:
    There's also unequal cost multi-path routing too - EIGRP supports that.

  • 3750 Cross-stack equal cost routes across different switches in the stack

    Hello,
    If I configure a cross stack ethernet channel does it support link aggregation to increase bandwidth or is it just support for link failover?

    Answer is support for link failover.
    The EtherChannel on multiple switches in the Cisco Catalyst 3750 stack is called cross-stack EtherChannel.
    If a link within an EtherChannel fails, traffic previously carried over that failed link changes to the remaining links 
    within the EtherChannel. A trap is sent for a failure, which identifies the switch, the EtherChannel, and the failed link. 
    Inbound broadcast and multicast packets on one link in an EtherChannel are blocked, and cannot return on any other link of the EtherChannel.
    HTH
    Regards
    inayath

Maybe you are looking for

  • Smart object - what happens to the pixels when i transform?

    So i place an image into an open photoshop document, using the place command, of course. it is now a smart object, my question is when i transform or resize without constrain proportions( for example only enlarge the width, the hight unchanged) resam

  • How do I start with audio first and add video to Imovie as the song plays?

    I want to start an Imovie project by adding video from my Isight camera to audio that I have put down first. This way I can sync my video to the audio in real time. When I have audio that will play, I am unable to add the video because the Isight cam

  • Error relinking during installation of 11.1.0.6

    Hello all, I'm trying to install Oracle 11.1.0.6 EE (software only) on an IBM machine running AIX 6.1.3. When I run the installer, it works fine until it gets to about 74% complete. Then, I get the following error: Exception Name: MakefileException E

  • Stuck in a loop

    I tried (should have known better) to send an email with a 261 MB attachment. Mail 1.3.11 "Unexpectently Quit" after grinding away for quite awhile trying to send. Now the message is in my out folder and the whole process starts over when I launch Ma

  • How to create colums with the same Field

    Hello every body, I have this report only with one field how i can create columns in base of rows for example some times  this field containing 40 rows then I need to create 2 columns of 20 that when is even or 15 then create 2 columns one with 8 row