Overflow converting from '-6.34431e+010'

hi,
when i was performing data transfer process in one process chain.
that time this problem came.
Also these message are coming.  Message no. RSTRAN301
Message no. RS_EXCEPTION000
also this line are comeing with message..
Data package 1 / 07.06.2011 05:46:12 / Status 'Processed with Errors'
Message no. SY530
Message no. RSBK231
Message no. RSBK257
when i delete request in target admin. then again repair process chain. It was giving same error
So can u tell me about this problem.

Hi,
BW Reporting only supports currency-dependent amounts of length 17 in the standard system.
Kindly check these OSS notes :
1316587 - Arithmetic overflow in statistics
460652  - Extending key figures in BW
If these doesnot help you , check in the PSA for the error record .
Locate the infoobject for which the error is occuring .
Then check for the infoobjects datatype in RSD1 and check whether the datatypes are matching or not .
Also check this SAP help link:
[SAP help|http://help.sap.com/saphelp_webas620/helpdata/en/fc/eb2fd9358411d1829f0000e829fbfe/frameset.htm]
Regards,
Lokesh

Similar Messages

  • Load failed due to Overflow converting from 853156+16

    Hi All,
    Load is getting failed from one DSO to another DSO with following error message. and its AP AR load
    Runtime error while executing rule -> see long text
    Message no. RSTRAN301
    Diagnosis
    An error occurred while executing a transformation rule:
    The exact error message is:
    Overflow converting from '8.85315e+16'
    The error was triggered at the following point in the program:
    Z_BFOD_A_AR_LOOKUP_ITEM_E 278
    System Response
    Processing the data record has been terminated.
    Procedure
    The following additional information is included in the higher-level node of
    the monitor:
    Transformation ID
    Data record number of the source record
    Number and name of the rule which produced the error
    Thanks,
    Asim

    Hey,
    Ask the developer that wrote the end routine to check the code where the error occurs. First check if too much data is transferred and if it can be reduced. Then also check if the object needs to be extended 460652 - Extending key figures in BW.
    Regards,
    Michael

  • DTP Request Error: "Overflow converting from ''" (Executing rule)

    Hi,
    I have an error for every dataset in my dtp:
    Anyone an idea?
    Error Ercords Display says:
    Runtime error while executing rule
    Longtext:
    Diagnosis
         An error occurred while executing a transformati
         The exact error message is:
         Overflow converting from ''
         The error was triggered at the following point i
         GPD5DB2R35UPL1XXBS1ICKUVG8O 2313
    System Response
         Processing the data record has been terminated.
    Procedure
         The following additional information is included in the hig
         node of the monitor:
         o   Transformation ID
         o   Data record number of the source record
         o   Number and name of the rule which produced the error

    Hi,
    It seems that there is a error in transformation routine. Are you filling any internal table  or converting any data type in the routine. Go to ST22 it will show you dump and give you line at which error is coming OR if you click on the message in DTP monitor it will divert you to the errorneous line.
    Regards,
    Viren

  • Failed to execute with the error Overflow converting from...

    I have a query filter for UPC in Webi Report. The report is not working for one UPC (for other UPC's the report is working fine)...it gives error "failed to execute with the error Overflow converting from '6218090010'. (WIS 10901)". The same error is coming when I ran MDX in MDXTEST command in BW. When I take the UPC filter from the query filter the report runs fine and I see this UPC in the report. The data source is Bex and we have recently upgraded to SAP EHP 1 for SAP NetWeaver 7.0.
    Regards
    Sharma

    Hi,
    Under normal circumstances it should be enough to restart the connection service.
    As far as we know there is no formal solution to this problem from SAP yet but restarting the connection service is much less of an interuption compared to restarting the the SIA.
    Re-starting the connection service should resolve this issue. since, Connection service is only related to DeskI and Rich Client re-statrng wonu2019t impact other business objects components including java report panel.
    All the Best,
    Madhu....

  • SAP BPC 10NW Overflow converting from ' -10949993089200.0000000

    Hi,
    I came across this problem when running the following package activities:
    1. Load Transactions Data from BW InfoProvider UI (Log says it is rejected file but it was recorded in BPC)
         Rejected Records:
    12 ,510000,INPUT,Budget,SMKR,PL99,G_NONE,I_NONE,SSG1KR10SMKRPC,LC,2014.12,-10949993089200.00
    Line0 :Overflow converting from ' -10949993089200.0000000 '
    2. Clear Package
         Rejected Records:
    700000,INPUT,Budget,SMKR,PL99,G_NONE,I_NONE,SSG1KR10SMKRPC,LC,2014.12,10840821887500.0000000
    Line0 :Overflow converting from ' 10840821887500.0000000 '
    Anybody can share idea how to handle this? Appreciate the help.
    Thanks.

    Transformation File:
    *OPTIONS
    FORMAT = DELIMITED
    HEADER = YES
    DELIMITER = ,
    AMOUNTDECIMALPOINT = .
    SKIP = 0
    SKIPIF = 
    VALIDATERECORDS=YES
    CREDITPOSITIVE=YES
    MAXREJECTCOUNT=-1
    ROUNDAMOUNT=*MAPPING
    *MAPPING
    ACCOUNT=0GL_ACCOUNT(5:10)
    AUDITID=*STR(INPUT)
    CATEGORY=*STR(Budget)
    ENTITY=0COMP_CODE
    FLOW=0GL_ACCOUNT(1:5)
    GROUPS=*STR(G_NONE)
    INTERCO=*IF(0PCOMPANY=*STR() then *STR(I_NONE);0PCOMPANY=*STR(999999) then *STR(I_NONE);0PCOMPANY)
    PFCTR=*IF(0PROFIT_CTR=*STR() then *STR(PC_NONE);*STR(SSG1)+0PROFIT_CTR)
    RPTCURRENCY=*STR(LC)
    TIME=0FISCPER
    AMOUNT=ZYTD_PL
    *CONVERSION
    ACCOUNT=COV_DATA_IMPORT_BSPL.xls
    ENTITY=COV_ENTITY_MD.xls
    FLOW=COV_DATA_IMPORT_BSPL.xls!FLOW
    TIME=COV_DATA_IMPORT_BSPL_TIME.xls

  • Overflow when converting from "1.64174e+11"

    Hi ,
    I am working on PS module and facing the above mentioned error.Whenever I am attching any material haveing value more than Rs 100000 the system gives "Overflow when converting from "1.64174e+11""
    The detailed error description is given below,
    Runtime Errors         CONVT_OVERFLOW
    Except.                CX_SY_CONVERSION_OVERFLOW
    Date and Time          24.11.2008 11:19:23
    Short dump has not been completely stored (too big)
    Short text
         Overflow when converting from "1.64174e+11"
    What happened?
         Error in the ABAP Application Program
         The current ABAP program "SAPFV45P" had to be terminated because it has
         come across a statement that unfortunately cannot be executed.
    Error analysis
         An exception occurred that is explained in detail below.
         The exception, which is assigned to class 'CX_SY_CONVERSION_OVERFLOW', was not
          caught in
         procedure "KALKULATIONSWERT_UEBERNEHMEN" "(FORM)", nor was it propagated by a
          RAISING clause.
         Since the caller of the procedure could not have anticipated that the
         exception would occur, the current program is terminated.
         The reason for the exception is:
         When attempting to convert the value "1.64174e+11", an overflow occurred.
    Missing RAISING Clause in Interface
         Program                                 SAPFV45P
         Include                                 FV45PF0K_KALKULATIONSWERT_UEBE
         Row                                     8
         Module type                             (FORM)
         Module Name                             KALKULATIONSWERT_UEBERNEHMEN
    Trigger Location of Exception
         Program                                 SAPFV45P
         Include                                 FV45PF0K_KALKULATIONSWERT_UEBE
         Row                                     140
         Module type                             (FORM)
         Module Name                             KALKULATIONSWERT_UEBERNEHMEN
    Source Code Extract
    Line  SourceCde
      110       MTCOM-MATNR = VBAP-MATNR.
      111       MTCOM-BWTAR = VBAP-BWTAR.
      112       CALL FUNCTION 'MATERIAL_READ'
      113            EXPORTING
      114                 SCHLUESSEL    = MTCOM
      115            IMPORTING
      116                 MATDATEN      = MBEW
      117            EXCEPTIONS
      118                 ERROR_MESSAGE = 04
      119                 OTHERS        = 04.
      120       MOVE SY-SUBRC TO SAV_SUBRC.
      121     ENDIF.
      122
      123     IF T685A-KRECH = 'C'.
      124       IF SAV_SUBRC = 0 AND MBEW-PEINH NE 0.
      125         KOMV-KPEIN = MBEW-PEINH.
      126       ELSE.
      127         KOMV-KPEIN = 1.
      128       ENDIF.
      129 * Falls keine ET da, Zielmenge nehmen (Gut-/Lastschrift, Kontrakt ...)
      130       DATA: DA_MENGE LIKE VBAP-KWMENG.
      131       IF TVAP-ETERL EQ SPACE AND VBAP-KWMENG = 0.
      132         DA_MENGE               = VBAP-ZMENG.
      133       ELSE.
      134         DA_MENGE               = VBAP-KWMENG.
      135       ENDIF.
      136       IF DA_MENGE > 0.
      137         DA_WERT         =  DA_WERT  * KOMV-KPEIN * 1000
      138                          / DA_MENGE * VBAP-UMVKN / VBAP-UMVKZ.
      139       ENDIF.
    >>>>>       KOMV-KBETR      = DA_WERT.
      141     ELSEIF T685A-KRECH = 'B'.
      142       KOMV-KBETR      = DA_WERT.
      143     ELSE.
      144       KOMV-KWERT      = DA_WERT.
      145     ENDIF.
      146
      147     KOMV-WAERS         = DA_KALKO-FWAER.
      148     RV45A-KOEIN        = DA_KALKO-FWAER.
      149     KOMV-KMEIN         = VBAP-MEINS.
      150     PERFORM KOMV_PRUEFEN USING SPACE
      151                          CHANGING SY-SUBRC.
      152 * Nur für den ersten Lauf prüfen, ob Status gesetzt werden muß
      153     IF SAV_INDEX = 1.
      154       DA_SUBRC = SY-SUBRC.
      155     ENDIF.
    156     IF SY-SUBRC = 0.
    157       PERFORM KOMV_BEARBEITEN.
    158     ENDIF.
    159   ENDDO.
    Pl suggest.
    Rgds

    Hi,
    Try to declare your variable using Packed Number:
    DATA: va_num TYPE P DECIMALS 3.
    Hope this helps.
    Patrick

  • Overflow when converting from "3.60001e+11"

    Hi Guys,
    I'm Working with my PO using MIRO, I don't know why the error occurs. I've used the SAP Version 620 but end up with an error, then used Version 710 and successfuly created the transaction, but I'm stacked with version 620. I'm not allowed to transact it using the Version 710 that's why im looking for a patch or upgrade within 620 that i can use so that it can be solve.
    I'm in need of your help guys. I know there someone out there that can help me.
    THE ERROR
    Runtime Errors         CONVT_OVERFLOW                                              
    Exception              CX_SY_CONVERSION_OVERFLOW                                   
           Occurred on     03/28/2011 at 01:00:47                                                                               
    Overflow when converting from "3.60001e+11"                                                                               
    What happened?                                                                               
    Error in ABAP application program.                                                                               
    The current ABAP program "SAPLEINS" had to be terminated because one of the        
    statements could not be executed.                                                                               
    This is probably due to an error in the ABAP program.                                                                               
    Error analysis                                                                               
    An exception occurred. This exception is dealt with in more detail below     
    . The exception, which is assigned to the class 'CX_SY_CONVERSION_OVERFLOW', 
    was neither                                                                 
    caught nor passed along using a RAISING clause, in the procedure             
    "DISTRIBUTE_ACC_ASSIGN_RE" "(FORM)"                                         
    Since the caller of the procedure could not have expected this exception     
    to occur, the running program was terminated.                               
    The reason for the exception is:                                             
    When attempting to convert the value "3.60001e+11",                          
    an overflow occurred.                                                        
    How to correct the error                                                                               
    The exception must either be prevented, caught within the procedure   
    "DISTRIBUTE_ACC_ASSIGN_RE"                                           
    "(FORM)", or declared in the procedure's RAISING clause.              
    To prevent the exception, note the following:                         
    If the error occurred in one of your own programs or in an SAP program
    that you modified, try to correct it yourself.                                                                               
    You may able to find an interim solution to the problem               
    in the SAP note system. If you have access to the note system yourself,
    use the following search criteria:

    I won't post here if i already got the answer in SAP notes. I've spent 3 days searching for the answer. The only answer i got is the upgrade but can't be consider. OSS notes didn't provide me any answer. Hope u can help me
    Edited by: docgon on Mar 30, 2011 2:38 AM

  • Upload maxdb  really needed? - Overflow when converting from 32768

    hello,
    I am facing with a run time error that does not make sense when uploading maxdb database. The error is:  "Overflow when converting from 32768".
    I am following this configuration tutorial:
    http://help.sap.com/saphelp_nwmobile71/helpdata/en/45/17a790d8000064e10000000a1553f7/frameset.htm
    Anyway, is there a need to upload this database? We installed netweaver mobile with SQL server database.
    Help please.
    Thanks.
    Edited by: João Carneiro on Feb 8, 2011 2:10 PM

    Hi,
    Uploading MAXDB is not mandatory. It is needed only when multiple devices need to be installed with MAXDB through setup or software packages, which helps administrator to roll out multiple devices, so that end users will get all the necessary software to install the device.
    Hope this clarifies your query.
    Thanks and Regards,
    Suma

  • RUNTIME ERROR IN GENERATED PROGRAM. Overflow converting ''

    Hi,
    While executing the below code i am getting the error
    " RUNTIME ERROR IN GENERATED PROGRAM. Overflow converting ' ' am new to ABAP , can anyone kindly help me where i have went wrong ? .
    IF ( V_DO_CDS_NAME_MAIN <> '' ).
        ABAP.
            DATA: ref_it_tab TYPE REF TO data,
                  ref_wa TYPE REF TO data.
            FIELD-SYMBOLS: <fs_itab> TYPE ANY TABLE.
            FIELD-SYMBOLS: <fs_wa> TYPE ANY.
            FIELD-SYMBOLS: <fs_field> TYPE ANY.
            CREATE DATA ref_it_tab TYPE STANDARD TABLE OF (V_DO_CDS_NAME_MAIN) WITH NON-UNIQUE DEFAULT KEY.
            ASSIGN ref_it_tab->* TO <fs_itab>.
            SELECT * FROM (V_DO_CDS_NAME_MAIN) INTO TABLE <fs_itab> where C1 = V_WORK_ITEM_ID_MAIN.
            CREATE DATA ref_wa LIKE LINE OF <fs_itab>.
            ASSIGN ref_wa->* TO <fs_wa>.
            loop at <fs_itab> assigning <fs_wa>.
                assign component 'CLIENT' of structure <fs_wa> to <fs_field>.
                V_CLIENT = <fs_field>.
                assign component 'C0' of structure <fs_wa> to <fs_field>.
                V_C0 = <fs_field>.
                assign component 'C1' of structure <fs_wa> to <fs_field>.
                V_C1 = <fs_field>.
                assign component 'C2' of structure <fs_wa> to <fs_field>.
                V_C2 = <fs_field>.
                assign component 'C3' of structure <fs_wa> to <fs_field>.
                V_C3 = <fs_field>.
                assign component 'C4' of structure <fs_wa> to <fs_field>.
                V_C4 = <fs_field>.
                assign component 'C5' of structure <fs_wa> to <fs_field>.
                V_C5 = <fs_field>.
                assign component 'C6' of structure <fs_wa> to <fs_field>.
                V_C6 = <fs_field>.
                assign component 'C7' of structure <fs_wa> to <fs_field>.
                V_C7 = <fs_field>.
                assign component 'C8' of structure <fs_wa> to <fs_field>.
                V_C8 = <fs_field>.
                assign component 'MESSAGE_ID' of structure <fs_wa> to <fs_field>.
                V_MESSAGE_ID = <fs_field>.
                assign component 'TIMESTAMP' of structure <fs_wa> to <fs_field>.
                V_TIMESTAMP = <fs_field>.
                assign component 'EXTRACTKEY' of structure <fs_wa> to <fs_field>.
                V_EXTRACTKEY = <fs_field>.
                assign component 'STATEID' of structure <fs_wa> to <fs_field>.
                V_STATEID = <fs_field>.
                assign component 'DEVICE_ID' of structure <fs_wa> to <fs_field>.
                V_DEVICE_ID = <fs_field>.
            ENDLOOP.
        ENDABAP.
    ENDIF.

    Hi Mubeen,
    While Copying the cotes have come closer otherwise its working fine , i was able to find the error .
    There are ten predefined ABAP data types. There are 100 possible type combinations between these elementary data types. ABAP supports automatic type conversion and length adjustment for all of them except type D (date) and type T (time) fields which cannot be converted into each other.
    I commented the TimeStamp part where i had given the ABAP Type as D and it started working .
    But now i want to display the content of  "TimeStamp"  field but i am not able to do so .
    This is the format in which it has to be displayed 2009.011.915.3353.
    Which ABAPTYPE i need to use ?.
    i am able to display in this format 20090119153353
    regards
    Harsha

  • Here i need to convert from EA to CS.

    Hi Dear friends,
    iam having one requirement. that is conversion.
    here is need to convert from EA to CS, for that one iam using FM: conversion_factor_get
    But this is not converting and when i run program it was showing the error is "conversion of dimensionless units is possible".
    Here i need to convert from EA to CS.
    this is Eg:
    DATA : LV_SS TYPE F,
           LV_DEC(100) TYPE N,
           LV_NUM(100) TYPE N.
    call function 'CONVERSION_FACTOR_GET'
    EXPORTING
       NO_TYPE_CHECK              = ' '
       UNIT_IN                    = 'EA'
       UNIT_OUT                   = 'CS'
    IMPORTING
       ADD_CONST                  = LV_SS
      DECIMALS                   = LV_DECI
       DENOMINATOR                = LV_DEC
      DIMENSION                  =
       NUMERATOR                  = LV_NUM
    EXCEPTIONS
      CONVERSION_NOT_FOUND       = 1
      OVERFLOW                   = 2
      TYPE_INVALID               = 3
      UNITS_MISSING              = 4
      UNIT_IN_NOT_FOUND          = 5
      UNIT_OUT_NOT_FOUND         = 6
      OTHERS                     = 7
    if SY-SUBRC <> 0.
    MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
            WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
    endif.
    write : lv_ss, lv_dec, lv_num.

    Hi
    first ensure that the both values CS and EA exist in the table T006
    then only the conversion of the units is possible using the fun module
    'CONVERSION_FACTOR_GET'
    Since the unit CS is not available in T006 table it is not working
    This fun module in turn uses the table data T006 for the conversion of units
    Regards
    Anji

  • How to convert from pt to mm

    Dear all,
    Does anybody know how to convert value of pt to value of mm according to language and font? Thanks a lot!
    Best regards,
    Christo
    Edited by: Christo Tan on Dec 22, 2011 5:51 AM
    Edited by: Christo Tan on Dec 22, 2011 6:00 AM

    The standard system (I am on ECC 6) doesn't come with a unit for Russian Point (Tochka in Russian). So we need to do the following to be able to convert from millimeter (mm) to Russian Point and vice versa. This is how we did it in our production system.
    1. In transaction CUNI create a new unit RP with LENGTH dimension. In the drop down list besides "Units of Measurement" button, select LENGTH dimension and enter values like in the below picture
    [Russian Point in transaction CUNI|http://img265.imagevenue.com/img.php?image=70210_UnitofMeasure_RussianPoint_122_100lo.jpg]
    2. In your ABAP program you can call UNIT_CONVERSION_SIMPLE like below to convert from RP to MM.
    DATA: lv_input TYPE I VALUE 1,
          lv_output TYPE F.
    CALL FUNCTION 'UNIT_CONVERSION_SIMPLE'
      EXPORTING
        input                      = lv_input
        NO_TYPE_CHECK              = 'X'
    *   ROUND_SIGN                 = ' '
        UNIT_IN                    = 'RP'
        UNIT_OUT                   = 'MM'
      IMPORTING
    *   ADD_CONST                  =
    *   DECIMALS                   =
    *   DENOMINATOR                =
    *   NUMERATOR                  =
        OUTPUT                     = lv_output
    * EXCEPTIONS
    *   CONVERSION_NOT_FOUND       = 1
    *   DIVISION_BY_ZERO           = 2
    *   INPUT_INVALID              = 3
    *   OUTPUT_INVALID             = 4
    *   OVERFLOW                   = 5
    *   TYPE_INVALID               = 6
    *   UNITS_MISSING              = 7
    *   UNIT_IN_NOT_FOUND          = 8
    *   UNIT_OUT_NOT_FOUND         = 9
    *   OTHERS                     = 10
    IF sy-subrc <> 0.
    * MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
    *         WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
    ENDIF.
    The above call converts 1 RP into 2.5400000000000000E-01 mm and puts it in lv_output (which is 0.254)

  • ABAP code needed to convert from 0calmonth2 & 0calyear to 0calmonth

    Hi SAP GURUS,
    Can anybody give me the ABAP code to convert from 0calmonth2 and 0calyear to 0calmonth.and please suggest me whether i have to write start routine or end routine in transformations.
    Thanks ALL.

    hi,
    in the transformation map 0calmonth2 and 0calyear to the 0calmonth field, and from drop down choose routine.
    there will be an area where it will be mentioned write your piece of code below this line.
    paste the below code:
    Concatenate source_fields-0calmonth2 source_fields-0calyear into result.
    also delete the line result = .
    save the routine and execute the package.
    regards,
    Arvind.

  • The bullet list, numbered list and the normal text is not converting when I am converting from RH 9 to MS Word 2010

    Hi all,
    Greetings for the day
    I am created a new CSS in Robohelp 9. I have also created a new template in Word 2010. The style sets for different information elements like (Heading, bullets, body text, ) are more or less same between the CSS and the new templates. I am also able to map the .css styles to Word template when I am converting from RH to Word as I am getting the necessary option in the drop-down list.
    However, when the output is generated, the bullet, the numbered list and the body text is not converting at all. The body text works sometimes. However, the numbered list and bullet list is coming out as images.
    If anybody knows the solution, I can share the .css and Word template.
    Thanks in advance.
    Regards,
    Parag Deb

    Create a new project with two or three topics containing lists of both types. Generate a printed output that shows the problem. Then zip it up and send it to me. See the Contact page on my site for instructions.
    See www.grainge.org for RoboHelp and Authoring tips
    @petergrainge

  • How do I convert from pdf to word? I see an option to do so, however, when I click on it, Ia box opens...

    when I try to convert from pdf to word, a box opens and suggests I am to click on (select) the file I want to convert. It sounds all well but it does not work. I really really just want my files back in word, all of them, no matter, because after having to reinstall windows 7 (done by techs) and me having to re-download all my HP drivers, and tools, and other software, which I imagine included adobe reader, now I see some pdf files won't open. It says, "access denied" and boy that really makes me wantt o scream. I am the ONLY user, it is my notebook, I am the administrator so I can't figure out why some files open and some don't. I can't ascertain any difference.
    I would be grateful for any help. This has become just too exhausting. After reinstalling sooooooooo much, then to have to go through this with what is a free application? I say I think not.
    This should NEVER happen with any free application and boy there is NO help to be found. They blow you off the phone fast telling you it's a free application. Then why are you putting in this kind of  stuff that it won't open? This is NOT a shared notebook, it's mine. I am the only user, personal use.
    HP probook, if anyone needs that info.
    Please, will someone help?
    I would be so grateful.
    thanks,
    Gina

    Gee, Pat, this is a  real big help.
    Nobody could possibly think anyone would ask for help without first trying to fix the issue oneself. Or maybe you do. I have opened the file and looked under security. I have changed it to owner-notebook (which is what the techs called me) and clicked accept but geepers it didn't work.
    Maybe someone else has an idea.
    Take Ownership of a File or Folder
    The above should be a link. At least I copied and pasted the link. I did what was stated in there. It isn't like brain surgery. But it is not working. I ended up being able to open some pdf files after transferring them from one partition category to another. I wish it was that easy as you seem to think.
    Thanks for the help. Have a great year.

  • How do you stop DNG Converter from embedding Adobe's ACR default settings instead of custom settings?

    I notice that the new version of Adobe DNG Converter (8.6, and maybe earlier) appears to place Adobe's ACR defaults in the converted file.  Thus, the converted files open up in Bridge with an indication that they already have settings made, and, hence, ACR does not apply the custom camera settings.  One has to Clear Settings first in Bridge, then open in ACR.
    This behavior is new, perhaps to 8.6.  But it's presence defeats the purpose of having custom Camera Defaults.
    Is there any way to prevent DNG Converter from installing settings?

    ssprengel wrote:
    What do you mean by “custom camera settings”?  Do you mean you’ve changed the Camera Raw defaults for a particular camera and those aren’t being seen until you do a Reset?  Or do you mean some sort of Nikon-settings that Adobe never looks at?
    Also at what point in the workflow are you converting these files, just after copying them to your hard-disk and before touching them with any other Adobe software, or after they’ve been adjusted in Nikon software, or after they’ve been adjusted in Bridge/ACR, initially as NEFs?
    I mean my custom camera defaults that are set by the Save New Camera Defaults for a given camera.
    My workflow is to take my original raw files first into Adobe DNG Converter.  I then open the folder in Bridge.  At this point I notice that my original raw files remain unaltered (there is no "settings" icon in the top right corner – circle with two lines and up-arrows – in the image's thumbnail), but the converted dng's (otherwise untouched and unopened in ACR) have a "settings" icon.  When I open the original raw file in ACR, it opens using my custom camera defaults.  When I open the otherwise virgin dng in ACR, it opens using the Adobe defaults (the same defaults that would be employed if no custom camera default had been set).
    This behavior is new.  DNGs formed by earlier versions of the DNG Converter did not apply any settings to the converted file, and when they opened in Bridge, they were given the custom camera settings.
    In order to retain the old (and proper) behavior, I now have to take the just-converted documents into Bridge, select them, and immediately apply Develop Settings/Clear Settings.  That gets rid of the settings that have been installed by the DNG Converter (as well as the "settings" icon on the thumbnail).
    I notice there is a new feature in Adobe DNG Converter 8.6, namely, a panel-specific toggle between the settings and the default settings. This indicates to me the likelihood that Adobe has been making some alterations with the settings that is having unintended consequences.  It clearly is not proper for DNG Converter to be adding (installing) settings, because that prevents the custom camera default settings from being applied, and hence defeats the purpose of the custom camera default settings.

Maybe you are looking for

  • Is WebLogic Server 10.3.6 for Windows 7 64-bit??

    Hey, I have a question for you. I'm on Windows 2008 R2 Xeon 64 bit. I've downloaded and installed both SunJDK and JRockit JDK to use the 64bit Weblogic generic installer: find default java version.. cd c:\ java -version java version "1.6.0_31" Java(T

  • Differences Between SAP PDF and Normal PDF Files ???

    Hi, In SAP, we are converting Delivery Outputs to PDF and getting with another win32 application using RFC. However, PDF's taken from SAP don't work like other PDF's which Created with Adobe PDF Creator. For Example, I have a delphi application which

  • How to send response back to db adapter

    Hi, I have a requirement where I need to update a status field and last activity time field ( time of instance completed) in a database table. I used Polling option in database adapter, but it is updating the status field immediately once it is read.

  • Suddenly NoSuchMethodError on calling DOCUMENT_CREATE2 with JCo

    Hi. I'm working with JCo to create ("BAPI_DOCUMENT_CREATE2") and modify ("BAPI_DOCUMENT_CHANGE2", "BAPI_DOCUMENT_DELETE") documents in SAP R/3. Until yesterday all worked fine. Suddenly I get a "NoSuchMethodError" if I call this methods. Is it possib

  • How send data to serial port from forms 6i

    How send data to serial port to activate hardware connect. The hardware is a drawer for cash the point of sales.