Passing Data to Webdynpro from normal module pool screen

Hi,
I am working on a requireent, where I have a normal screen with some fields and a button. When I click on the button I want to navigate to the webdynpro screen and also pass the data from the screen to web dynpro.
Any suggestion is really appriciated.
Thanks
Sanjaya

Hi Sanjaya,
  DATA lv_app TYPE swfvtv-vval.
  DATA lv_url TYPE string.
  DATA lv_url_pre TYPE string.
  DATA lv_url_suff TYPE string.
  DATA lv_task TYPE swfvtv-task.
  DATA lv_memid TYPE string.
  DATA lt_param TYPE tihttpnvp.
  DATA ls_param TYPE LINE OF tihttpnvp.
  DATA lo_window_manager TYPE REF TO if_wd_window_manager.
  DATA lo_api_component  TYPE REF TO if_wd_component.
  DATA lo_window         TYPE REF TO if_wd_window.
Get Application Name.
  lv_task = sworklist-external_type.
  DATA lt_swfvtv TYPE TABLE OF swfvtv.
  DATA ls_swfvtv TYPE swfvtv.
Get WD parameters
  SELECT *
  FROM   swfvtv
  INTO   CORRESPONDING FIELDS OF TABLE lt_swfvtv
  WHERE  task EQ lv_task
  AND    vtyp EQ 'WD_ABAP'.
  IF sy-subrc NE 0.
    RAISE not_found.
  ENDIF.
Create application name in PAPPL
Get namespace
  READ TABLE lt_swfvtv INTO ls_swfvtv WITH KEY vpar = 'NAMESPACE' .
  IF sy-subrc EQ 0.
    CONCATENATE pappl ls_swfvtv-vval INTO pappl SEPARATED BY '/'.
  ENDIF.
Get application name
  READ TABLE lt_swfvtv INTO ls_swfvtv WITH KEY vpar = 'APPLICATION' .
  IF sy-subrc EQ 0.
    CONCATENATE pappl ls_swfvtv-vval INTO pappl SEPARATED BY '/'.
  ENDIF.
Construct URL for application name.
  lv_url = pappl.
  CALL METHOD cl_wd_utilities=>construct_wd_url
    EXPORTING
      application_name = lv_url
      in_parameters    = lt_param
    IMPORTING
      out_absolute_url = lv_url.
  SPLIT lv_url AT '?' INTO lv_url_pre lv_url_suff.
  IF lv_url_suff IS NOT INITIAL.
    CONCATENATE '&' lv_url_suff INTO lv_url_suff.
  ENDIF.
  CONCATENATE lv_url_pre '?sap-client=' sy-mandt '&sap-language=' sy-langu lv_url_suff '&WI_ID=' sworklist-external_id
INTO   lv_url.
Create window for application.
  lo_api_component  = wd_this->wd_get_api( ).
  lo_window_manager = lo_api_component->get_window_manager( ).
  lo_window         = lo_window_manager->create_external_window(
                        url = lv_url
                        has_menubar = abap_false
                        has_toolbar = abap_false
                        has_location = abap_false ).
  lo_window->set_window_size( width = '700' height = '500' ).
  lo_window->open( ).
This is the code to generate the URL for a Web Dynpro Application.
modify the code according to need.
Hope this will help you.
Thanks &Regards,
Arvind
Hey i dont know why is this coming like this when posted.
Copy-paste this in modify in editor.
Edited by: Arvind Patel on Jun 16, 2010 2:35 PM

Similar Messages

  • Call LSMW from a Module pool screen

    Hi SAP gurus,
    In order to call an LSMW from a module pool screen, there is a Function module which I have used earlier, but unable to recollect it. Can someone please tell me the FM which we need to use ?

    Sudhakar,
    Create an LSMW and assign it to a tcode and then call this tcode from the module pool program so that it  will skip all the screens just by allowing the user to input the files and run the lswm.
    Regarding the FM I have no idea.
    K.Kiran.

  • Regarding exit from the module pool screen

    h experts,
    i have developed a module pool report in which in the selection screen i have four fields which are mandatory ,when i execute the program without entering in the selection screen it do not allow to come out of the module pool screen ...what i want that without entering any input in the selection screen if i press exit button push button it will allow to come out of the screen for this what sud i do plz help me....

    Hi
    keep a button called <b>EXIT</b> on the screen
    Make the function type of that field as <b>E</b>
    in Flow logic write
    PROCESS AFTER INPUT.
    Forced Exit from the transaction from screen
      MODULE exit AT EXIT-COMMAND.
    double click on exit module and
    then in PAI write
    *&      Module  exit  INPUT
    Exit from the Transaction
    MODULE exit INPUT.
      CASE okcode.
        WHEN 'EXIT' OR 'CANCEL'.
          CLEAR okcode.
          LEAVE PROGRAM.
      ENDCASE.
    ENDMODULE.                 " exit  INPUT
    <b>Reward points for useful Answers</b>
    Regards
    Anji

  • How to display image and data in module pool screen?

    Hi,
    I want to display image and relevant data besides the image in module pool screen, I am using docking container to display the image.
    Actually I am able to display image or data any one but not both.
    one more thing I want to display multiple images and their data.
    Please suggest some one if you have any idea.
    Regards,
    Dileep.

    You can try below way, I have used in report.
    DATA: gc_docking              TYPE REF TO cl_gui_docking_container, "#EC NEEDED  "Docking Container
           gc_split                 TYPE REF TO cl_gui_easy_splitter_container, "#EC NEEDED  "Splitter
           gc_top_container         TYPE REF TO cl_gui_container, "#EC NEEDED  "Top Container
           gc_bottom_container      TYPE REF TO cl_gui_container, "#EC NEEDED  "Bottom Container
          gc_document              TYPE REF TO cl_dd_document, "#EC NEEDED  "Document
           gc_events                TYPE REF TO lcl_event_class, "#EC NEEDED  " Local Event Class
           gc_grid                  TYPE REF TO cl_gui_alv_grid, "#EC NEEDED  " ALV Class
    " Creating Docking
    CREATE OBJECT gc_docking
           EXPORTING
             ratio = c_95.
         IF sy-subrc EQ 0.
    * Splitting the Docking container
           CREATE OBJECT gc_split
             EXPORTING
               parent        = gc_docking
               sash_position = c_10 "Position of Splitter Bar (in Percent)
               with_border   = c_1. "With Border = 1 Without Border = 0
         ENDIF.
    *   Placing the containers in the splitter
         gc_top_container = gc_split->top_left_container .
         gc_bottom_container = gc_split->bottom_right_container .
    *   Creating Grid
         CREATE OBJECT gc_grid
           EXPORTING
             i_parent = gc_bottom_container.
       ELSE.
    * Background job handling
         CREATE OBJECT gc_grid
           EXPORTING
             i_parent = gc_docking.
       ENDIF.
    *   Creating the document
       CREATE OBJECT gc_document
         EXPORTING
           style = 'ALV_GRID'.
    Regards,
    Sameer

  • How to create select-options on module pool screen

    Hi all
    I want get a range of values from the user from the module pool screen.
    Is there any element available on module pool screen like select options on the selection screen of reports.
    reply me ASAS.
    Thanks.

    hi krishna
    actually I want to display the details of PO numbers from 45000100 to 45000150. user will enter this range on the module pool screen just as we enter on the selection screen of report. My question is do we have a button like select-option on the module pool screen.
    Plz . reply me ASAP.
    Thanks.

  • Call module pool screen from ABAP Webdynpro

    Hi All
    I designed one screen in normal classical dynpro in SE80 for module pool program. I want to call that screen layout design in webdynpro view layout.
    So please help me how can i call that module pool screen from my ABAP webdynpro 

    Hi
    Thank you for your great replay. But Mr Ramakrishnappa and Mr Katrice as your reference i go through that but when i insert the program name and screen number program is end with a run time error saying
    dynamic type conflict when assigning reference.
    Please refer the below snap shot

  • Calling webdynpro in module pool screen

    Hi All,
    I need to display webdynpro application in module pool custom container.
    I am using method cl_wd_utilities=>construct_wd_url , then i am using G_HTML_CONTROL->SHOW_URL to show the webdynpro component.
    Issue is it is taking to logon screen in module pool and after login, it is working as desired.
    Any idea how to suppress this logon screen.
    Thanks in advance

    Hi,
    The SSO needs to be configured.
    Also, try the function module WDY_EXECUTE_IN_PLACE, and pass the parameters appropriately.
    Integration of Web Dynpro ABAP Applications in GUI Applications - Web Dynpro for ABAP - SAP Library
    You can directly create a parameter tcode using WDYID.So that you can call wd applicaiton's tcode directly in gui which launches the application with SSO
    Please refer the below link
    Single Sign On from SAP GUI to Webdynpro
    Hope this helps you.
    Regards,
    Rama
    Message was edited by: Ramakrishnappa Gangappa

  • Display Continuous Fluctuations in Input Data in Module Pool Screen

    Dear All,
    We are working on a Weighbridge Interface scenario, where the weighbridge is sending data to a digitizer, which is connected to the COM port of a PC. The objective is to read the data from the digitizer, and display in a Module pool screen. However, there is one more requirement: the weight may fluctuate until it stabilizes, and the fluctuations have to be displayed on screen. For example, the tare weight of a vehicle may be 12.4 TON, but when the vehicle is standing on the weighbridge, the weight may vary from 10.4 to 12.4 TON. The idea is to capture the stable weight, so that any discrepancies can be avoided. In the current IT system implementation, the fluctuations in the weight are displayed. But using ABAP, can these fluctuations be captured? For example, we may design a screen containing a field for capturing the weight, and the weight displayed there automatically refreshes as soon as there is a change in the digitizer reading. Is this possible to achieve? If so, how?
    Awaiting answers.
    Thanks and Regards,
    Sid

    Hi Sid,
    just a suggestion for the refreshing of an ABAP screen: you can use class CL_GUI_TIMER, but it only handles whole seconds, i.e. 1 second, 2 seconds and so on, but not 0.5 seconds...
    An example of an ABAP listing could be the following:
    *& Report  ZZAVV001
    REPORT  zzavv001 NO STANDARD PAGE HEADING.
    CONSTANTS: c_yes(1) TYPE c VALUE 'X'.
    DATA: BEGIN OF t_bseg OCCURS 0.
            INCLUDE STRUCTURE bseg.
    DATA: END OF t_bseg.
    data: d_num_bkpf type i,
          d_num_bseg type i.
    PARAMETERS: interval TYPE i DEFAULT 5.  "meaning 5 seconds
    *       CLASS lcl_receiver DEFINITION
    CLASS lcl_receiver DEFINITION.
      PUBLIC SECTION.
        METHODS:
          handle_finished FOR EVENT finished OF cl_gui_timer.
    ENDCLASS.                    "lcl_receiver DEFINITION
    * Global data
    DATA:
      test       TYPE i,
      receiver   TYPE REF TO lcl_receiver,
      timer      TYPE REF TO cl_gui_timer.
    START-OF-SELECTION.
      CREATE OBJECT timer.
      CREATE OBJECT receiver.
      SET HANDLER receiver->handle_finished FOR timer.
      timer->interval = interval.
      CALL METHOD timer->run.
      PERFORM load_data.   "or whatever you have to do to read the weight
      PERFORM show_list.   "or whatever you have to do to print the weight you've read
    *       CLASS lcl_receiver IMPLEMENTATION
    CLASS lcl_receiver IMPLEMENTATION.
      METHOD handle_finished.
        PERFORM carga_datos.
        PERFORM muestra_listado.
        CALL METHOD timer->run.
      ENDMETHOD.                    "handle_finished
    ENDCLASS.                    "lcl_receiver IMPLEMENTATION
    *&      Form  load_data
    *       text
    FORM load_data.
      clear: d_num_bkpf,
             d_num_bseg.
      select single count( * )
        into d_num_bkpf
        from bkpf.
      select single count( * )
        into d_num_bseg
        from bseg.
    ENDFORM.                    "load_data
    *&      Form  show_list
    *       text
    FORM show_list.
      get time.
      skip to line 1.
      position 1.
      write: / 'Date / Time:', sy-datum, sy-uzeit.
      write: / 'Number of BKPF records:', d_num_bkpf.
      write: / 'Number of BSEG records:', d_num_bseg.
    ENDFORM.                    " show_list
    Okay, it's just a tiny code snippet, but I hope it may help you by designing auto-refreshing screens.
    Kind regards,
    Alvaro

  • Who worked with ICS' Model 4896 GPIB? I can not count the data from the module. Can prompt as it to make. It is desirable with examples (data read-out from the module and data transmission between channels. It is in advance grateful.

    I can not count the data from the module. Can prompt as it to make. It is desirable with examples (data read-out from the module and data transmission between channels. It is in advance grateful.

    Hello. Most of the engineers in developer exchange are more familiar
    with NI products. Contacting ICS for technical support is a better
    course of action.

  • Copying from report output to a module pool screen

    Hi to all experts
    My requirement is to call a transaction when i click a button in module pool programme .when i execute that transaction an alv report is displayed and user selects some records that should be copied over to the module pool screen.

    Yous should use ALV OOps concept to capture the selected data in the ALV report , and once you return back you can update yr module pool .

  • Trigger a workflow from module pool screen at save button

    Hi,
    I am new to workflow.Please help me.My requirement is trigger a custom workflow from module pool screen at save button.
    Scenario is: Create a Z screen for material creation and after pressing save button workflow should trigger to approver and approver emailid should be fetch from Z table and have to provide a link in work flow for Z t-code which displays a report of material pending for approval..
    Please suggest me process how i can acheive this..
    Thanks

    Hi,
    If you're using standard bapi's to save the material, you can then use either the standard events which are already triggered or you coul add a change document for material changes or creation.
    Then this event can be the trigger of your custom workflow.
    Kind regards, Rob Dielemans

  • Module-pool screen field value under POV event

    Hi All,
    I have one issue...please suggest me solution for this.
    In module-pool program i have one screen(1000) which has one field(hrname_1000).
    Under this event:
    PROCESS ON VALUE-REQUEST.
    FIELD hrname_1000  MODULE hrname_1000.
    under this module hename_1000 i have used F4IF_INT_TABLE_VALUE_REQUEST to put a search help for field hrname_1000.
    after that i am trying to retrive HR related stuff's based on the field on module-pool i.e i am using hrname_1000 in the where condition.
    but problem is that im not getting value for hrname_1000 which im giving in the module-pool screen.
    thats y my select query is not working.
    Where as im getting values for the hrname_1000 under PBO & PAI.
    It will look like below.
    PROCESS ON VALUE-REQUEST.
    FIELD hrname_1000  MODULE hrname_1000.
    (under the above module)
      SELECT DISTINCT ename plans FROM pa0001 INTO CORRESPONDING FIELDS OF TABLE itab WHERE stell = '50001026'.
          LOOP AT itab INTO wa WHERE ename = hrname_1000.
          ENDLOOP.
    Please suggest
    Thanks & regards
    Ansumesh

    In some of the cases the screen field is present in the screen but not holding the value in the required structure or field.
    so here u need to check the option of reading the screen field values explictly..
    //once u hit an enter and do the f4 i think the value will be there ...but if u dont hit enter and do an F4 the value cannot hold and i think u r in this case ..
      1.Fill the screen field name in the structure dynpread.
    DATA: BEGIN OF DYNP_VALUES OCCURS 10.
            INCLUDE STRUCTURE DYNPREAD.
    DATA: END   OF DYNP_VALUES.
    DYNP_VALUES-FIELDNAME = 'HRNAME_1000'.
      APPEND DYNP_VALUES.
    * read screen values
      CALL FUNCTION 'DYNP_VALUES_READ'
        EXPORTING
          DYNAME     = HELP_REPID  "call the repid of ur prog
          DYNUMB     = HELP_DYNNR "pass the screen number
        TABLES
          DYNPFIELDS = DYNP_VALUES
        EXCEPTIONS
          OTHERS     = 1.
    now dynp_values hold the field name and field value of the screen .
    now
    SORT DYNP_VALUES BY FIELDNAME.
        READ TABLE DYNP_VALUES WITH KEY 'HRNAME_1000' BINARY SEARCH.
        IF SY-SUBRC EQ 0.
          HELP_XXXX = DYNP_VALUES-FIELDVALUE. "store the value into a variable
          TRANSLATE HELP_XXXX TO UPPER CASE.               
        ENDIF.
    Now check the code with the value if its getting populated which once there will make ur select work ..
    Vijay..

  • How can one save variants for module pool screens.

    hai all,
         i have done a module pool screen for taking information from user..later i leave to list processor and give a report to the user.
      i am testing the program with many input parameters.i don't want to enter the values each time i execute the program.can i not save a variant like i save for normal abap editor programs?
    any other solution ?

    Hii..
    Variants can be created in Selection Screen only...
    For ur Scenario:
    To leave to the list use the Statements
    <b>LEAVE TO LIST-PROCESSING And return .</b>
    then the Data will be automatically retained.
    <b>Reward if Helpful</b>

  • How to use table maintenance view in module pool screen

    hi ,
    want to use table maintenance view in a module pool screen so that i can edit, insert, delete and update date in to the ztable.please help.

    You can simply call it via SM30.   Or you can call the table maintence view from any program(report or module pool) using a function module.
      call function 'VIEW_MAINTENANCE_CALL'
           exporting
                action                       = 'U'
                view_name                    = 'Z_Table_Name'
           exceptions
                client_reference             = 1
                foreign_lock                 = 2
                invalid_action               = 3
                no_clientindependent_auth    = 4
                no_database_function         = 5
                no_editor_function           = 6
                no_show_auth                 = 7
                no_tvdir_entry               = 8
                no_upd_auth                  = 9
                only_show_allowed            = 10
                system_failure               = 11
                unknown_field_in_dba_sellist = 12
                view_not_found               = 13
                others                       = 14.
    Regards,
    RIch Heilman

  • How to insert tabstrip control in module pool screen painter

    Hi all!
    plz tell e how to use tabstrip control in module pool screen painter.Also plz give me an example program using tabstrip control.

    To insert tabstrip just open layout of screen and press on the tabstrip button there .
    Use this souce code further to activate it .
    CONTROLS tabstrip TYPE TABSTRIP.
    DATA: okcode TYPE sy-ucomm,
    dynnr TYPE sy-dynnr,
    flag type flag,
    active like tabstrip-activetab .
    call SCREEN 100.
    *& Module USER_COMMAND_0100 INPUT
    text
    MODULE USER_COMMAND_0100 INPUT.
    data: lv_okcode type syucomm.
    lv_okcode = okcode.
    clear okcode.
    case lv_okcode.
    WHEN 'TAB1'.
    dynnr = '0110'.
    WHEN 'TAB2'.
    dynnr = '0120'.
    WHEN 'TAB3'.
    dynnr = '0130'.
    WHEN 'TAB4'.
    dynnr = '0140'.
    WHEN 'TAB5'.
    "check authorization, if authorization fails
    flag = 'X'. "set the global flag
    active = 'TAB1'. "store active tab in global variable
    dynnr = '0110'. "set the screen number
    WHEN 'BACK' or 'EXIT'.
    leave program.
    ENDCASE.
    IF lv_okcode(3) = 'TAB'.
    tabstrip-activetab = lv_okcode.
    ENDIF.
    ENDMODULE. " USER_COMMAND_0100 INPUT
    *& Module STATUS_0100 OUTPUT
    text
    MODULE STATUS_0100 OUTPUT.
    SET PF-STATUS 'MAIN'.
    SET TITLEBAR 'xxx'.
    IF tabstrip-activetab IS INITIAL OR
    dynnr IS INITIAL.
    tabstrip-activetab = 'TAB1'.
    dynnr = '0110'.
    ENDIF.
    "set the activetab explicilty here
    if flag eq 'X'. "from authorization failure
    tabstrip-activetab = active. "'TAB1'
    clear flag.
    endif.
    ENDMODULE. " STATUS_0100 OUTPUT

Maybe you are looking for

  • XMl Publisher intigration with OAF  Multiple VO's

    Hi Experts, i need to open the report out put in document viewer and i fallowed below url http://apps2fusion.com/at/ps/294-bi-publisher-document-viewer-common-region-embeded-report-output-in-oa-framework-page-part-2 But now my problem is i have multi

  • Scaling in BeX report

    Hi, Have anyone experience the following problem: BW version 3.5 In the ODS the numbers reflect correctly scaled as from the source (i.e. 65,000.00 JPY). However when we execute the BeX report it appears to be 6,500,000.00. We've checked the query fo

  • Upgrading from iPhoto 2 to iPhoto 5

    I am about to upgrade to iPhoto 5. Aside from having a backup of all my pictures, what else (if anything) should I do before upgrading? After I upgrade? Any other suggestions? Thanks.

  • Two dependent SelectOneChoise objects...

    Hi, everyone! I have two dependent select one choice objects! See: http://my.jetscreenshot.com/2677/20100715-6suo-55kb Then I run my jspx page. First time when I choose values from first LOV, then secend LOV shows needed values. But when I repeat act

  • JScrollPane - scrolling to the top