PCI-6023E maximum working voltage2

Thanks Mr. Alan A
I am "434343" memeber.
I recive your response to my question about "Max input voltage of PCI-6023E" .But I have some questions.
According to the "Data Acquistion Specification- a Glossary by Richard House" ( Application Note 092):
"Maximum Working Voltage (signal+common mode)= the highest voltage level that can be input to board without saturating the input."
And according to your response:
"measuring a signal with higher common mode voltage than that(11V) might not accurate"
But in may experiment with a potentiometer (floating differntial source with (-)13.5V and (+) 5to22V),I could successfully measure the signal without saturating and without error (Max error is about +/- 0.02 volt)!!
I think that the maximum working voltage of PCI-6023E is greater then 11 volt??!!
or my measurement has a little error.
I think that I don't need to use a signal conditioning circuit.
Please Help me.
Thans again.
Edward Hb.

Please see this thread.
-Alan A.

Similar Messages

  • PCI-6023E DAQ card maximum sampling frequency

    Hello
    I am using PCI-6023E DAQ card in pc-based ETS solution (and writing appilication in LabView 7.1 with RT module). The card has 200kS/s maximum sampling frequency, but it can be set for much higher sampling frequencies and the waveform acquired appears to be correct (i.e. i've tried setting it fo 1MS/s and sampling 400kHz sine, which is obviously above Nyquist frequency for 200kS/s card, but on spectral graph, main peak is at 400kHz). Is the card driver doing some kind of free/coherent sampling?
    Moreover, when sampling frequency is set to 200kS/s, the card seems to be doing same thing - i.e. for 200kS/s and sample block size of 200kS, graph should be updated once in a second, but it's updating slighty slower.
    I'd really appreciate if someone could explain me (or gave me a link to materials) what exactly is happening here? Is driver doing some background work, or maybe it is problem with network latency/unstability ? What is the impact of this effect on real-time aquisition?
    Thanks in advance
    Jan Kienig

    Since the fundemental is 4 times the nyquist, then what you are measuring is an alias of the fundemental. This works well as long as the fundemental is a repetitive signal. Sampling every other peak and every other node looks the same as sampling every peak and node. Tektronix exploited this on their 7S series sampling heads. Another use of this phenomena is the effective demodulation of high frequency signals as long as the bandwidth meets nyquist. As with your card, if the input amplifier supported it, I could extract modulation information from a 500 MHz signal so long as the the bandwith of that modulation did not exceed 100 kHz.
    Parker

  • PCI-6023E & digital output

    Hello,
    I have a PCI-6023E and I want to generate a continous pulse train with a digital output line, and I need to know the maximum frequency for this pulse train that I can generate.
    Thanks a lot for your answer.
    Regards, Anacelia

    Hi Anacelia,
    You should not realy on this answer without verifying with NI first. So here goes.
    Page 347 of the catalog indicates the supported data transfer mode is "programed I/O". This indicates that each line state change must be initiated by an operation of the controlling software. Therefore, the upper frequency limit is determined by how often the code that sets or resets the line runs.
    So, the upper limit is determined by the software and the environment it is running in. If you are woring in Windows environment, and your machine is faster than about 400 Mhz then there are two factors to concider when answering your question. How fast does the code run, and how deterministic is it.
    If determinism is not an issue, you could resonably expect to get
    about one update every 10ms if the code is clean. This would give you 100 update per second or about 50Hz.
    If determinism is required, and you are not running in a Real Time environment, the above estimates should be backed off. Anything above 5-10Hz is going to be questionable.
    Like I said, verify what I have said with NI.
    I hope this helps,
    Ben
    Ben Rayner
    I am currently active on.. MainStream Preppers
    Rayner's Ridge is under construction

  • Alternative to PCI-6023E + PCI-6602

    Hello,
    I am already using a system to acquire 16 analog inputs data (at 50Hz) and 100Hz PWM signals (counters) and to send 100Hz PWM signals to external devices. Because it deals with 12 concurrent counters I bought 2 x PCI-6602 counter boards on top of a PCI-6023E for the 16 analog inputs (through a SC2345 box). This works all well.
    I now have to build a simplified and portable solution that has to run on a laptop. I was thinking about a DAQ-6036E or DAQ-6024E (or even DAQ-6062E) and keep a SC2345 but do not know if I will get the same functionalities particularly for the PWM counting (in and out). I have to be able to count the high edge of the square signal at 100Hz while acquiring my analog inputs; also be able to generate those 100Hz signals. Will I be able to connect my counter in and counter out (one of each) to the SC2345 to do that?
    Thanks for your comments,
    Christophe

    Hello Christ0phe,
    Looking at your current specifications and hardware, the best suitable solution for a portable appication with >2 counters would be the Compact RIO Platform.
    As this is an FPGA based platform, you can implement (theoretically) as much counters for PWM generation and reading as you want.
    As you are an existing DAQ user, you will not be able to reuse your existing code.  The cRIO platform uses the NI-RIO driver which is using some different program logic than the NI-DAQmx driver.
    Why is the Compact RIO platform the best solution?
    Well, the cRIO chassis can be powered by a simply DC power supply. Depending which chassis this is between 9 and 30 VDC.
    The cRIO platform also has a dedicated controller inside which will run your LabVIEW code.  The PWM logic itself can run on the FPGA integrated in the cRIO chassis.
    So, the laptop will not be use for any calculation, only for monitoring and control of your application.
    If you want to stay with the NI DAQ plaform I see two other portable solutions:
    The first one is to make the swtich to the PXI platform.
    There is a small chassis (PXI-1033) which has an integrated MXI-interface. Using MXI technology, you can control a PXI chassis from another PC, including a laptop (using ExpressCard, not PCMCIA).
    For the PXI platform you can use identical or similar DAQ boards as you have now, reusing your existing LabVIEW code.
    Drawback of the PXI-1033 is that it can only be powered by 230VAC, you will have to provide a DC-to 230VAC converter yourself to be able to use it in the field.
    For your information. It's becoming harder and harder to find laptops with PCMCIA slots, ExpressCard is the successor available on most new laptops.
    But please have a look at following article concerning laptop compatibility: http://zone.ni.com/devzone/cda/tut/p/id/5035
    A last solution is to use the cDAQ plaform.
    Again a fully portable DAQ solution, but as it uses the same technology as the 'normal' DAQ boards, it only has 2 counters on board.
    As your PWM speeds are quite slow, it may although be possible to use this platform for multiple PWM signal generation and reading.  All will depend on the desired PWM accuracy (resolution) and if they all share the same signal period.
    It is possible to use the 2 on-board counters as a known sample clock to generate and read the PWM pulses using correlated DIO.
    Correlated DIO means that your digital input and output signals are hardware clocked (synchronized with other available clock source). On the cDAQ platform, your I/O modules must be placed in slot 1-4 of the cDAQ chassis to be able to use correlated DIO.  Possible I/O modules are in the C-series 940x range.
    Drawback: all your calculations have to be done on the fly in LabVIEW.  You will need to write code to generate an array
    of digital waveform data, then output it using hardware timed DIO
    synchronized to generate counter clock.  For the readout of the PWM signal, you will have to count (within the LV application) the number of tick (of pulses) of the sample clock during which the PWM signal was 'high' and calculate based on the known timing information the PWM on-time, period (and if needed duty cycle). 
    More info about cDAQ and Correlated DIO:
    NI-DAQmx: Correlated Digital I/O with NI CompactDAQ and LabVIEW
    Can I Use Different Sample Clocks for Correlated DI and DO?
    Some examples exist:
    CompactDAQ - Generating More Than 2 Pulse Trains
    NI-DAQmx: Digital Channel Pulse Width Modulation (PWM)
    This info should already help you make a selection.
    But please contact you local National Instruments office if you need more information.
    Best regards,
    Best regards,
    Joeri
    National Instruments
    Applications Engineering
    http://www.ni.com/ask
    Make our forums great:
    If you like the answer, don't forget to "Kudos!".
    "Accept the Solution" if your question is answered!

  • PCI 6023E Analog Input with DAQmx

    Hello everybody,
    I have some problems with a PCI 6023E Card. I`m using Lab View 7.1 on Windows 2000.
    When i start the MAX (Devices and.../NI-DAQmx - Devices.../PCI-6023E) and try to open the "Testpanel"
    i get the following message:
    Lab View: An exeption occurred within the external code
    called by a Call Library Node. This might have corrupted
    Lab Views memory. Save any work to a new location and
    restart Lab View.
    VI "BlockatContainerState2.vi" was stopped at node
    0xA10 of Sub VI "DAQmx

    sorry i had a problem thats the rest of the message
    Sub VI "DAQmx Assistant_DAQmx Create AI Channel (sub).vi"
    i get the same message when i try to use the DAQmx Assistant for
    analog Input measurements in Lab View.
    I hope you can help me
    best regards
    Chris

  • Problem when configure polarity on PCI-6023E

    I tried to set the polarity of an analog input channel with AI_configure. When I call AI_Configure with polarity Bipolar(default) anything works fine. but when I change the polarity to unipolar, the status code -10003 is returned, indicating that the value of my parameter is invalid. The PCI-6023E is software configurable, isn't it?
    Attachments:
    AI_configure.txt ‏1 KB

    Stephan;
    The 6023E board can only be configured as bipolar mode.
    Take a look at the board Users Manual to double check that information.
    Regards
    Filipe

  • Error 10401 - PCI 6023E

    Hello everyone,
    I have a LabView code running on LabView 6.1 (on Windows 2000).  It has a PCI 6023E DAQ card.
    Everything was working fine for many days, until suddenly today I got the Error 10401 - occured at AO Single update.
    if I click OK, the code tries to run then displays the same error again and again.   I have attached the LabView code. 
    I checked in NI-MAX, and the device is located there as (Dev1), and seems to be fine.  I also tried restarting the computer but still get the same error.
    What might be the problem?  Any help is appreciated.  Thanks.
    Attachments:
    Lion_Rail_Pressure_Control.vi ‏92 KB

    Hi nithyan2,
    I believe that you are using Traditional DAQ drivers, please take a look to this article.
    Best,
    Carmen C.

  • Reading PCI-6023E counter by Delphi/NI-DAQ

    One current goal of mine is to read out the counter of a NI I/O board PCI-6023E by Delphi/NI-DAQ! But I don't get it work.
    I am interested in having a Delphi code using NI-DAQ commands *without ActiveX components*. At NI support doesn't exist yet any example code in Delphi using NI-DAQ just commands.
    What part is missing in my code "PCI6023E_Counter.pas"?
    http://www.home.fh-karlsruhe.de/~egra0011/Projects/SIM
    The "same" prog in VB works fine! Do the NI-DAQ commands/drivers work with Delphi? Thanks.

    Rawi,
    NI-DAQ provides a function prototype for Borland Delphi, so NI-DAQ function calls should work fine in that environment. Your program seems to be correct. However, you don't state why it's not working, and I've noticed that you don't seem to be checking the iStatus return value for an NI-DAQ error. You might want to check to see if an error is being returned. That could point you in the right direction. If you continue to have problems, I would recommend contacting National Instruments support for troubleshooting assistance.
    Also, the counter/timer developer exchange is targeted towards 660X and TIO-10 counter/timer products. The PCI-6023E is a multifunction I/O board, and in the future, you may want to consider posting your inquiries to the multifuncti
    on I/O exchange for assistance.
    Regards,
    Erin

  • Can't get my pci modem to work in the ms - 6215

    does anyone know how to get my pci modem to work in a ms - 6215, I've tried everything that I can think of including installing a modem  known to be good, since the motherboard is very unique in so that it has a riser that only has two pci slots on it and I've tried both of them, the os is windows me and when I first booted up all it found was an unknown pci card so I told it it was the modem and when I went to the modems in the control panel it tells me that it couldn't open the port even though the irq and com port info is the same in windows as to the post screen, the type of modem is a pctell 56k, and the guy who brought me this thing told me he didn't have the driver cd that came with it but since I have a external modem that worked with it I was able to update all of the motherboard drivers...
    thanks
    Michael Croskrey
    ([email protected])

    Did you get a correct ME driver for your Modem?

  • Sound triggering on PCI-6023E

    I am using a PCI-6023E card. I wish to use a sound signal to trigger the data acquisition. Since it has only external digital triggering, my best guess is to run a sub-VI that reads the microphone channel and then sends a digital output to the external trigger channel. Any better suggestions? Any comments on the brain-drain effects of this on my buffered data (while waiting for the trigger event)?
    thanks

    Hello,
    Depending on the level of the sound signal that you will be receiving, doing an analog input and then in software determining if the level if your signal is high enough would be your best option if the sound signal you are receiving is not a TTL signal. But, as far as then generating a digital output that then triggers the analog input externally doesn't seem to be needed. If you are producing a software signal to trigger something anyway, you may as well just start the analog acquisition in software once your subvi has determined it is time instead of generating a digital output that then hardware triggers the acquisition.
    Regards,
    Steven B.
    National Instruments

  • Labview doesn't recoginze the PCI-6023E card

    Hi there,
      I have labview 7 installed in a windows 7 32 bit system. I just have a PCI-6023E card installed and the windows device manager said that device is ready to use. I am trying to install the driver on the CD but NI just fail to recognize that card

    Hi dragondriver,
    AG@Amfax is right, this LabVIEW version is not supported in Windows 7. The oldest supported version is LabVIEW 2009 SP1. Please take a look to this compatibility chart.
    Once you have a compatible LabVIEW installed in the OS, you'll need a compatible driver version. Please refer to this link.
    Best,
    Carmen C.

  • Can PCI-6023E support hardware Analog trigger

    I try to use the PCI-6023E to do the hardware analog triggering, but it gives me the Error-10403 while I test with the vi example, Aiacquires N Scans Analog Hardware Trig.vi. Is there any way for this board to do the hardware triggering?

    Jack,
    The PCI-6023E DAQ board only supports digital triggering. You can check all the features of this board in the Data Sheet and Specifications on the Catalog page (see link below)
    2002 Catalog - PCI-6023E
    http://sine.ni.com/apps/we/nioc.vp?cid=1063〈=US
    If you need to perform analog triggering, you have three options:
    1) You can simulate it by acquiring continuosly all the signals that you want to monitor including the one that acts as the analog trigger. Compare the value read from this last one with the boundary that is supposed to trigger the acquisition, and when the value read reaches this boundary, you can save or display the data from all your channels.
    2) You could implement an external circuit that will compare the analog trigger signa
    l with the boundary value, and when they coincide, will generate a digital pulse that you can use as a digital trigger. This option optimizes your CPU usage.
    You can find detail information on how to set up the digital trigger in Chapter 4>>Timing Connections of the User Manual linked below.
    6023E/6024E/6025E User Manual
    http://digital.ni.com/manuals.nsf/websearch/0C88F40FFE7F28CD862569AE00574AC1?OpenDocument&node=132100_US
    3) Finally, you could get one of our boards that supports analog triggering. The PCI-MIO-16E-4 board has similar specifications that the PCI-6023E, and it has some additional features as well. See link below for more information.
    2002 Catalog - PCI-MIO-16E-4
    http://sine.ni.com/apps/we/nioc.vp?lang=US&cid=10795
    Good luck with your application,
    Claudia Lorente
    Applications Engineer
    National Instruments

  • NI-DAQ PCI-6023E nt embedded component

    Hi all
    I am trying to develop a KDF component for a ni-daq pci-6023e card and when
    I create the registy some keys stay in the CurrentControlSet instead of
    being related to ControlSet001. Can anyone help me???
    Is there a solution to this problem or a different approach I can use???
    Does anyone know if Nationnal Instruments have kdf file created???
    Many Thanks!
    Rémi Gauvin
    MC Countermeasures Inc.

    Hi Rimi,
    While searching for a possible solution to your question, I came across a Knowledgebase entry on our web site. Its ID is 251BSUKN. Although PCI-6023 is not specififcally included there, taking a look at it might provide you some good insight into the problem. Also in this knowledge base, you will find an attachment of the kdf files. Please do take a look at the tutorial under the related links too. To access the knowledgebase, go to ni.com/support and type this knowledgebase ID in the search box at the bottom of the page.
    I hope this helps.
    Sincerely,
    Sastry Vadlamani
    Applications Engineer
    National Instruments

  • Maximum work process hold time exeeded

    HI ALL,
    My user is running one Report painter report. He is getting the values in the report with out any issue. But after trying to filter the data, he is getting the error as "Maximum work process hold time exeeded".
    And some times he is getting the same error while exporting the data to the local file from the report.
    Is it because of SAP GUI version and patch level?
    Kindly let us know.
    Thanks & Regards
    Shankar

    HI Pradeep,
    Thanks for your reponse.
    Could you please give me some details of that technical step, where i have to set the time , where can i get that parameter ID etc...
    Thanks In advance.
    shankar

  • Can I use the 2 digital triggers on the PCI-6023E to trigger 2 seperate Analog inputs on the same board?

    I want to monitor 2 analog DC signals (single point measurements, not a waveform) and I want to use the digital triggers to start the acquisition, 1 trigger for 1 AI. the measurements need to be made at 1Hz, maybe slower. Is this possible with the PCI-6023E?
    If not what hardware should I be looking at? I have a total of 6 triggers and 6 AI.

    Dimentia,
    I would need confirmation on what you want to do:
    1) I want to monitor 2 analog DC signals
    This means that you will have one Analog Input operation monitoring two channels. Please confirm.
    2) single point measurements, not a waveform
    Ok, no buffers.
    3) I want to use the digital triggers to start the acquisition, 1 trigger for 1 AI
    This would mean that a single digital pulse or edge on a single line would start your 2-channel analog input operation. Please confirm.
    4) the measurements need to be made at 1Hz, maybe slower.
    Hardware-timed or software-timed? 1 Hz could be easily implemented with software timing. But the triggering could force you to use hardware timing. It will not be a problem but it would be good to know.
    5) Is
    this possible with the PCI-6023E?
    Everything I mention above is possible with the PCI-6023E.
    6) I have a total of 6 triggers and 6 AI.
    This last phrase is what really confuses me and seems to contradict the previous sentences. Does this mean that you will want to perform 6 independent Analog Input operations, with its own triggers (one each)? Will every Analog Input operation have 2 channels?
    I'll clarify why this is important:
    - Each Analog Input operation can only have one hardware digital start trigger assigned to it.
    - Only one Analog Input operation (multiple channels allowed) can be performed per board at any time.
    Since the rates are so slow I would recommend that you perform sample all channels within a continuous acquisition and then discard the data that does not meet a certain condition. You could sample the triggers as well and discard those channels for which the trigger has not been received.
    These are just some ideas based on my assumptions on the
    problem. Assumptions are never a good thing so please confirm on the point s above and we'll try to help.
    Thanks
    Alejandro Asenjo
    Applications Engineering
    National Instruments

Maybe you are looking for

  • Problem with Java keystore and certificates (unable to find valid cert path

    Our program is made so that when a certificate is not signed by a trusted Certification Authority, it will ask the user if he/her wishes to trust the certificate or not. If they decide to trust the certificate, it will accept the self signed certific

  • BDC for FF67 not displaying the line itmes of second page

    Hi all, I am using the Z BDC report Manual Bank Statement Upload (FF67). The BDC is as mentioned below : We are using start variant in the BDC. The report is working fine but the issue is that suppose if their are 45 line items and on one page we can

  • Original DVD does not get recognized

    Hi, My original DVD's were no longer recognized. CD's and DVD's burned by me all work ok. I think the error must be due to a malfunction of HAL because the DVD. I lost the weekend searching in google and trying solutions I've seen in the forum, but I

  • 2 player, Blackjack any suggestions?helppp

    ive been designing my program of BlackJack, everything coding wise i know how to do it and have a layout of it. what im stuck on is coding 2 players into my program and ive ran out of ideas. the problem is i cant hardcode that Player 1 goes, then Pla

  • How to make new InDesign work on new Mac?

    Hi, I have an old version of ID which works fine on my old Mac. I just bought a new Mac desktop and a new CS5. I can open a new doc but when I go to Preferences, it crashes and I get a message that ID quit unexpectedly. What to do?