PCI 6025e initialisation with MHDDK & INtime

Hi to all,
i successfully used my NI E series PCI card with MHDDK and RTX (using OSIbus implementations for RTX and E series MHDDK examples). Now i try to
use it with the INtime samples provided on NI website. I'm sure that my NI card ID
string is "PXI5::9::INSTR" (works well with RTX), the lsdaq sample (which scans for PCI hardware with NI Vendor) returns me
"PXI5::0::INSTR" but both values failed to init the card using
example.sln (AcquireBoard) : device is not found (PciFindDevice fails).
Do you have any clues where the problem comes from ?
Thanks in advance,
Antoine Nourry
Solved!
Go to Solution.

The problem is solved and came from pciDev.wDeviceId. It was set to #define NI_ESERIES_DAQ 0x11C0, eventually i had to use 0x2A80 for my card (found in nimhddk_rtx.inf, MHDDK RTX package). The card ID string returns by lsdaq was correct : "PXI5::0::INSTR" and misleaded me during multiple tests.

Similar Messages

  • DIO functions in MHDDK E series for PCI 6025E

    Hi, 
    I am currently developing a E series driver for 64 bits platforms. I didn't find, in the MHDDK, DIO functions for cards like PCI 6025E with digital I/O located in more than one port. 
    Can you please help me with that? Are there functions for DIO port selection and configurations in MHDDK E series?
    Thanks.

    Hi KBoussema,
    Unfortunately, addressing the other ports is unsupported in the DDK. If you need more DIO lines, you could consider looking at an M Series or X Series board.
    Steven K.
    National Instruments
    DAQ Software Engineer

  • Using PCI-6025E with quadrature encoder.

    Hi,
    i'm presently trying to figure out if i can use the PCI-6025E Card to count up/down with a quadrature encoder with no additionnal hardware. I know my answer lies in a document called "Using Quadrature Encoders with E Series DAQ Boards document " but it is not presently available on the ni website.
    Can any1 either confirm me that i can do this or send me the document?
    Thank you,
    Max

    This link seems to confirm that you can
    Link
    Randall Pursley

  • Using PCI-6025E with CVI2010

    I have been bring older legacy CVI Programs to windows 7 and have gotten a snag with use of a PCI-6025E card.  The compiler project works fine in windows XP but when it has been brought over to win 7 it does not drive the DIO ports.
    I checked the the card functions with NI-MAX with no issues.
    Not sure if it is a driver problem or i have to include a new library in the old source code moving into windows 7.  i have the latest NI-DAQ installed but the original libraries that the source code was compiled with was from 2007.
    Anyone have any ideas?
    Thanks

    Hi,
    Could you please confirm if the DIO lines work using a CVI example? -> C:\Users\Public\Documents\National Instruments\NI-DAQ\Examples\DotNET4.5\Digital
    Regards,
    - Miguel

  • Trouble using the counter on PCI 6025E

    Hello,
    I am facing a problem with the counter on PCI 6025E. I am trying to count the number of pulses generated by the shaft encoder mounted on the shaft of a motor. I am using a channel from the shaft encoder to count the pulses and generate the line state. So, I have wired the channel to pins 25[line state]and 47[counter]on SCB-100. In my application I am using the count events/time vi from DAQ palette. Every time I run my application I have been getting the error NI 10001 saying that the ordering of the strings is not as expected.

    Hi,
    The Count Events & Time.vi is typically used with older counter hardware such as the 9513 chip. Your E Series card (6025E) uses a DAQ-STC chip. The best way to count your edges is to open up the example "Count Edges(DAQ-STC).vi which can be found by selecting Help>>Find Examples... and you will find it under the DAQ Counter examples as an DAQ-STC example. Hope that helps.
    Ron

  • Poor performance accessing PCI-6025E

    NI Software : Visual C++ version 6.0
    NI Hardware : Multifunction DAQ device PCI-6025E
    Driver Version : 6.9.1
    OS : Windows 2000
    I am having a problem with the speed at which the card is accessed. This only occurs on one computer. Other computers are working fine and the code that we
    wrote is the same for all computers. Interestingly, the Test Panel seems to work fine on the computer that isn't running my software right. Also, my software appears to run fine on the slow computer for about 3-5 seconds before it bogs down. Specifically, a call to AI_VRead goes from basically instantaneous response to taking 300-500 milliseconds. The computer with
    the problem is something like a 3GHz P4.

    Could it be a video (or other) driver issue? IRQ issues can cause hiccups like the one you mentioned.

  • Is PCI-6025E full duplexing ?

    Do E series DAQ boards work in full-duplex mode ? Especially PCI-6025E .

    I believe I may have sent you an e-mail about this. However, I would be glad to post about it here as well.
    Full-duplexing is not a term we commonly associate with our DAQ boards. It is usually used in reference to serial-type communication that can go both ways at the same time (such as a modem). The best answer I can give on this is that the 6025E you asked about has 3 additional DIO ports (PA, PB, PC) which can operate in Bi-Directional Mode. This allows them to function as both inputs and outputs. The 6025E User's Manual is the best place to find more information about this.
    Ross C
    National Instruments

  • Acquisition using PCI-6025E yields undesired additional voltage offset

    I want to acquire the ouput voltage of an Instrumentation Amplifier using PCI 6025E card and LabVIEW
    But It reads a value which is much higher than the actual value. (ex. 5.23V for 1.20V)
    But I am able to read the voltage with multimeter correctly.
    Kindly suggest a solution.

    Hello-
    Can you please let us know a bit more about how you're configuring your tasks and connecting the signals?
    Are you using a differential connection or grounding one of the pins (i.e. RSE as suggested by TipTop)?
    Also, are you creating the tasks/channels programmatically or in MAX? Also, do you see the same behavior in Test Panels in MAX?
    Any insight into the connections and how you're measuring them would be helpful in troubleshooting the problem.
    Thanks,
    Tom W
    National Instruments

  • How do you do a timed DIG out on a PCI-6025E board?

    Im using a 4 channel DI/O of known frequency and duty cycle, and need a timed output on a PCI-6025E board.

    Hi abradamn,
    I dug around and found a few examples that may help you:
    Continuously Generating Digital Pattern Output
    Which DIO Ports to use on 6025E card
    I'm not quite clear on the wording of your question. Are you asking about having 4 timed channels of digital output, or a single channel of output, with 4 channels of input?
    Also, it might be a good idea to initialize your Digital Ports prior to use. Here is a good document on how to do it.
    Setting Default State of Digital Lines on E Series Boards
    Hope this helps!
    Jeremy L.
    National Instruments
    Jeremy L.
    National Instruments

  • Mac pro and motu PCIe audio card with a 2408mkIII

    mac pro and motu PCIe
    i recently upgraded to the mac pro from a G5 and now my motu 2408 mkIII sound card does not work.
    i installed the motu PCIe 424 pci card from motu and installed the latest UB drivers, followed the instructions to the letter, repeated numerous times in every pci e slot with only temporary luck. it worked briefly and then when the computer slept i lost the connection with the interface and have not been able to regain it.. yes i re-installed to the letter again. the pcie card is seen by the computer but it cannot seen the external rack mounted 2408 via the audiowire that connects it. yes i tried other cables. the unit worked fine on my G5.
    i have heard of others with the same problem after updating the firmware to SMC 1.7. my mac pro came with the latest firmware.
    Message was edited by: tara ntula

    another user forum wrote this on 8 august 2007 in regards to their mac pro.
    To my surprise I had five software updates waiting for me. Among them Pro App update, two of them, and this SMC update. After I updated my MOTU PCI-424 audio interface no longer works. Tried installing MOTU drivers again, still nothing. It can't communicate with its audio interfaces. So right now, this amazing update from Apple stopped me from working, and I am on a pretty tight deadline. I hope I'll find a solution ASAP

  • Installed PCI-6025E recognized by Windows XP but only in PXI system by MAX

    I installed a PCI-6025E DAQ board on a Windows XP machine. Upon startup it recognized the new hardware and installed the driver from the NI-DAQ 6.9.3 CD. All seemed to work fine. When I try to bring up the device in MAX it only shows up in the PXI system section. This doesn't assign a device number or allow a test panel. So I don't know how to access the signal from Labview programs. Is there something I haven't done right?

    Hello magicjoecuda,
    In general it sounds like you have done everything right and it is not that surprising that the 6025E shows up as a PXI device, but it is unexpected that it does nost appear as a DAQ device. I would try 2 things to work around this:
    1) Try installing the card in a different PCI slot on the computer.
    2) Uninstall the 6.9.3 driver and try installing the newest version of the driver. A link to the newest version of the driver for your board can be found here:
    http://www.ni.com/support/daq/versions_pci_pxi.htm
    Take care,
    E.Lee
    Eric
    DE For Life!

  • Ich benötige einen Treiber für die PCI-6025E. Beim Resurcentest fällt sie aus.

    Der PC erkennt die Karte nicht. Er sagt die Resurcen passen nicht.

    Halo R Thanner,
    Der Treiber für NI-DAQ 6.9.3 kann hier heruntergeladen werden. Der soll mit der PCI-6025E Karte passen.
    Schönen guten Tag!
    Robert M
    Applications Engineer
    National Instruments
    Robert Mortensen
    Software Engineer
    National Instruments

  • Instalar Tarjeta DAQ PCI 6025E en Windows XP

    Al instalar la tarjeta DAQ PCI 6025E en un PC con Windows XP me genera un conflicto. Creo que no es compatible. Segun el CD NI-DAQ, sirve para Windows 2000/NT/9x, y no para XP. Y ademas el CD de NI-DAQ es una version mas antigua de la que tengo instalada en mi PC.
    ¿Tengo que actualizar el controlador de la tarjeta? (driver) ¿de donde lo bajo?
    Otra pregunta: ¿en que enlace de NI puedo encontrar el manual del DAQ Signal Accesory? pues lo estamos probando pero no hay ningun efecto en el MAX (con una tarjeta Lab-PC+).
    Gracias.

    Hola
    La tarjeta 6025E debe funcionar sin problemas en XP.
    Los drivers van incluidos en NI-DAQ, y para esta tarjeta deberias instalar NI-DAQ 7 o posterior.
    El ultimo es el 7.3 enlace: http://digital.ni.com/softlib.nsf/webcategories/9A​D71162B755F0E786256BBC005F001A?OpenDocument&node=1​32060_US
    Son 2 cd, o sea que quizas sea mejor que se lo pidas a tu distribuidor de NI.
    Te recomiendo que quites la tarjeta de pc, desinstales todo lo de NI-DAQ que tengas, y a continuacion, intalas de nuevo NI-daq, y ,una vez instalado, pinchas la tarjeta y procedes con la instalacion automatica de windows. No dejes de instalar el NI-MAX para pruebas y configuraciones( va con el ni-daq).
    Antes de instalar ni-daq, confirma que es compatible con tu otro soft de NI.
    En el link que t
    e envio, a la izquierda veras manuals. pinchalo y busca el manual de tu hardware.
    espero que te salga bien
    saludos
    alipio
    "Qod natura non dat, Salmantica non praestat"

  • PCI 4351 cjc with SCB-68

    Is it possible to enable cold junction compensation using a PCI 4351 board with a SCB-68 terminal block?
    I have searched around and tentatively concluded that it is not possible.  Under the "accessory" option in MAX SCB-68 is not an option, and TBX-68 does not have a checkbox for temperature compensation.

    Hello Craig,
    National Instruments recommends the following accessories that are designed to be used with the NI 435x for thermocouples/CJC: the cold-junction sensor is on analog channel 0 on the TC-2190, TBX-68T, and CB-68T accessories. Additionally, the NI TBX-68T (used with NI 435x devices only) is the correct acccesory which includes a built-in cold-junction compensation sensor and autozeroing circuitry (compared to TBX-68).
    Best regards,
    Ali M
    Applications Engineer
    National instruments

  • I am using the PCI-6110E/​6111E with the NI-DAQ software version6.7​.Is there a way to record at the same time analog and digital channels?I​f,ye

    s can I have timestamps for each sample?I mean,is there a notion of time information on this board?Finally,is there a way to know ,in the double buffer's case,the number of samples in the halfbuffer which is not full if the acquisition stops by a trigger?.I am using the PCI-6110E/6111E with the NI-DAQ software version6.7.Is there a way to record at the same time analog and digital channels?If,yes can I have timestamps for each sample?I mean,is there a notion of time information on this board?Finally,is there a way to know ,in the double buffer's case,the number of samples in the halfbuffer which is not full if the acquisition
    stops by a trigger?.
    Thank you for your interest in advance

    s can I have timestamps for each sample?I mean,is there a notion of time information on this board?Finally,is there a way to know ,in the double buffer's case,the number of samples in the halfbuffer which is not full if the acquisition stops by a trigger?.PALE wrote:
    >
    > I am using the PCI-6110E/6111E with the NI-DAQ software version6.7.Is
    > there a way to record at the same time analog and digital
    > channels?If,yes can I have timestamps for each sample?I mean,is there
    > a notion of time information on this board?Finally,is there a way to
    > know ,in the double buffer's case,the number of samples in the
    > halfbuffer which is not full if the acquisition stops by a trigger?.
    Start by looking around the examples that ship with LabVIEW (if you are
    using LabVIEW).
    Also look around zone.ni.com for general data acquisition information &
    examples. A good site.
    Mark

Maybe you are looking for

  • Mountain Lion 10.8.2 Will not Boot

    I'm on an early 2011 MBP. I have a 256GB SSD with OSX on it and a 500GB HDD with a data partition and a boot camp partition. I just updated from 10.8.1 to 10.8.2. When the I turn it on, the start progress indicator fills up then the machine turns off

  • Change data capture from DRM to Target system

    Hi All, I have a situation where client wants Hyperion DRM to be single source of truth and pass Hierarchy information from DRM to subscribing target systems. There are 3 target systems and the database is MS SQL server. Now in the export profile ,I

  • HT1222 i updated the software and my phone is not working how can i delet updated software

    i updated the software advance IOS in my i phone after updation i got problem n i want to remove this

  • Printing blank spaces using dbms_output.put_line

    There is one string getting generated dynamically. Upon generation, it may or may not contain blank spaces in the beginning. Then I am trying to print this on standard I/O using DBMS_OUTPUT.PUT_LINE. But if there are some leading spaces in the string

  • Backgroung sceduling

    I have one program in selection screen I am giving job name my requirement is if I press execute button I need to run the report in the back ground under the job name mentioned in the selection screen based on the input parameters maintained in the s