Performance Problem After Upgrade

Hi Gurus,
We have successfully Upgrade our system R3 4.6c to ECC6, Database Oracle 10g on AIX.
Now we are facing Performance Problem. when we are checking Tables are taking Huge time to update data.
Regards,
Darshan...

Thanks! AC,
Performance Problem is resolved.
Now facing problem in RFC SAPXPG_DBDEST_ECCDB
Logon     Connection Error
Error Details     Error when opening an RFC connection
Error Details     ERROR: SAP gateway connection failed. Is SAP gateway started?
Error Details     LOCATION: SAP-Server eccci_LRP_00 on host eccci (wp 14)
Error Details     COMPONENT: CPIC
Error Details     COUNTER: 18
Error Details     MODULE:
Error Details     LINE:
Error Details     RETURN CODE: 236
Error Details     SUBRC: 0
Error Details     RELEASE: 700
Error Details     TIME: Tue Mar 17 11:57:01 2009
Error Details     VERSION:
Regards,
Darshan..

Similar Messages

  • 3D performance problems after upgrading memory

    I recently purchased an additional 2GB of memory to try and extend the life of my aging computer.  I installed the memory yesterday and Windows seems to recognize it (reporting now 3.3GB) but when I dropped into WoW (pretty much the only game I have) the 3D performance was down from the usual 60FPS @ 1600x1080 to a bleak 20 (at best) and the CPU utilization went to about 80% on both cores (with ~20% kernel usages).  Basically WoW was being software 3D rendered!!!
    I went through the usual reinstall drivers, reboot, etc... and couldn't find a fix.  I powered down, pulled out 2 of the memory sticks, booted up, and dropped into WoW - it ran at the full 60FPS and CPU utilization was very low (i.e. back to GPU Hardware 3D rendering).  I powered down again, swapped the 2 sticks for the other 2 sticks, booted up, and dropped into WoW - again it ran 100% fine.  So I powered down, put all four sticks in, booted back up, and when I dropped into WoW it was running in the software 3D rendering mode (20FPS at best and High CPU/Kernel usage).
    I've tried the /PAE option in boot.ini - no joy.  I've tried /MAXMEM = to 3300, 3072, 3000, and even 2048 - no joy in any of those cases.  Has anyone seen anything like this before?  Or have suggestions to fix (other than going to Win7-64)?
    All info in signature is up to date.
    Thanks in advance for any help!

    Quote
    Well his last post was a little over 6 hours ago so he was up pretty late.
    Looks like nothing one does in here goes completely unnoticed.   
    Anyway, I am done sleeping now.
    Quote
    his 2 Pfennig's worth.  I know, I know it's Euro's now.
    Yeah, and what used to be "Pfennige" is now also called "Cents" and here are mine:
    Quote
    I've tried the /PAE option in boot.ini - no joy.  I've tried /MAXMEM = to 3300, 3072, 3000, and even 2048 - no joy in any of those cases.  Has anyone seen anything like this before?  Or have suggestions to fix (other than going to Win7-64)?
    PAE or Physical Memory Extension will not do anything as Microsoft has castrated this feature to such an extend that it has nothing to do with memory addressing anymore when in comes to Windows XP:
    http://en.wikipedia.org/wiki/Physical_Address_Extension#Microsoft_Windows
    Quote
    Windows XP Service Pack 2 and later, by default, on processors with the no-execute (NX) or execute-disable (XD) feature, runs in PAE mode in order to allow NX. The NX (or XD) bit resides in bit 63 of the page table entry and, without PAE, page table entries only have 32 bits; therefore PAE mode is required if the NX feature is to be exploited. However, desktop versions of Windows (Windows XP, Windows Vista) limit physical address space to 4 GiB for driver compatibility reasons.
    The feature is already automatically enabled.  But since is original function (Address Extension) does no longer exist when it comes to the desktop versions of Windows XP, it won't really do anything you would ever notice.
    About the /MAXMEM Switch:  In Windows 32bit operating systems, every process is limited to 2GB of memory.  The point of the switch is to allow certain applications (or their run-time process) to occupy a higher amount of system memory than 2GB.  However, the culprit here is that only those applications are able to utilize this ability that have been programmed (or compiled) accordingly.  A special flag (large memory aware) has to be implemented.  Otherwise, these application will be restricted to 2GB even though the /MAXMEM Switch has been set to extend the 2GB limit to 3GB.  Most 32bit applications come without the "large memory aware" flag and that is why usually, settings the switch won't change anything.
    In any case, it is unlikely that /PAE (even if it would not be castrated) and /MAXMEM would have an impact on your actual issue because I doubt that it has much to do with either memory adressing or the memory limit of an indiviual Windows process.
    Quote
    the 3D performance was down from the usual 60FPS @ 1600x1080 to a bleak 20 (at best) and the CPU utilization went to about 80% on both cores (with ~20% kernel usages).
    There are a couple of hardware based explanations to consider here.  Let's start with the most obvious one:
    1. 975X Memory Controller
    The main reason that the system chooses to automatically set the Memory Speed to DDR2-667 even though DDR2-800 modules are installed, is that by design the memory controller of the Intel 975X Chipset does not natively support DDR2-800 modules, but
    >>Intel® 975X Express Chipset Datasheet - For the Intel® 82975X Memory Controller Hub (MCH)<< [Page 20]
    This means, that from the point of view of the memory controller, operating the memory @DDR2-800 actually means overclocking it (with all potential side effects).
    Basically, if your initial problem disappears as soon as you reduce the memory speed to DDR2-667, the design limitation of the memory controller may explain your findings.
    2. Different memory modules
    If I read your signature correctly, you are actually mixing two different kits/models of RAM (CM2X1024-6400C4DHX and  CM2X1024-6400C4).  This can work of course, but in practice it not necessarely does under all circumstances. 
    This list  (-> http://ramlist.i4memory.com/ddr2/) indicates that there are at least 14 different module types/revisions of Corsair DDR2-800 / CL4 modules that utilize a wide range of different memory chips (Elpida, ProMos, Micron, Infinion, Powerchip, Qimonda, Samsung, Infinion etc.).  Even though the superficial specifications for these chips appear to be pretty similar (DDR2-800 / CL5 / CL4), this does not necessarely mean that the modules will respond to the same operating conditions in the same way. There may be small difference in sub-timings/sub-latencies and/or the general responsiveness of the ICs which may affect the operating behaviour of the memory controller (which by the way also includes the PCI-Express interface which your video card is hooked up to).
    And again:  If running the system @DDR2-667 solves your issue, the possible explanation is that higher clock speeds may amplify (or trigger) potential performance problems that could have to do with the use of non-identical memory modules.
    Furthermore: It is also possible that the memory controller's design limitations and the potential compatibility problems that may be attributed to mixing different modules types may reinforce each other in terms of reduced system performance.
    3. The BIOS may have an impact as well
    There has been known issue with the use of certain video cards in conjunction with 4GB of system memory on this mainboard:
    https://forum-en.msi.com/index.php?topic=107301.0
    https://forum-en.msi.com/index.php?topic=105955.0
    https://forum-en.msi.com/index.php?topic=99818.msg798951#msg798951
    What may have come out as graphics/display corruption in earlier BIOS Releases may come out as reduced system performance when using the latest BIOS Release.  Of course, this is hard to prove, but I thought I'd mention it anyway.  May I ask what amount of video memory your card has onboard?
    Fortunately, there is a BIOS version that you could consider to try in this matter.  It is not only the last BIOS Release that could be used in order to avoid the corruption issue, but it is (in my oppionion) the best BIOS Version that was ever released for the 975X Platinum PUE Mainboard:  W7246IMS.716 [v7.1b6].  I have been using this mainboard for almost two years and have tested almost every BIOS Release that ever came out and I always went back to v7.1b6 as "ground zero". 
    It will properly support your E6600 (so you don't have to worry about that) and as far as I remember, there are no known compatibility issues with other components.  So maybe, you want to give this a shot.
    The bottom line is that in a worst case scenario, the problem you describe could be caused by all of the above things at the same time.  You cannot really do anything about the 975X Chipset Specifications and the only way to rule out explanation #2 is to test modules that are actually identical (same model number, revision and memory chips).  A test of the 7.1b6 BIOS Release is something you should consider.  It may be the only way to test the BIOS Hypothesis.
    This post turned out to be longer than I intended, but then again, I am well-rested after a good sleep and the wake-up coffee is kicking in pretty good.

  • Performance Problem After upgrade to oracle 10g

    Hi
    I have upgrade one of my datawarehouse database from oracle 9.2.0.8 to oracle 10.2.0.4 running on solaris 9
    After the upgrade jobs which were running in the database is taking hell lot of time.
    The jobs are accessing the views which is used to get the monthly report data from the database.
    what could be the solution and where to start from to get the RCA to resolve this performance issue
    Please let me know if you require any other information
    database is currently running in the automatic shared memory management mode ie SGA_MAX and SGA_TARGET parameters are defined for that

    There are a lot of differences between 10g and 9i in this regard, among these are:
    - There is a default job that gathers statistics every night which is not there in 9i. You might have totally different statistics as in 9i due to that job, depending on how and if at all you used to collect statistics in 9i
    - The 10g DBMS_STATS package collects histograms on some columns by default (parameter METHOD_OPT=>'FOR ALL COLUMNS SIZE AUTO' default in 10g whereas 'FOR ALL COLUMNS SIZE 1' in 9i) which can have a significant effect on the execution plans
    - The 10g optimizer has CPU costing enabled by default which can make significant changes to your execution plans due to different costing of table scans and order of predicate evaluation. In addition it uses NOWORKLOAD system statistics if system statistics have not been gathered explicitly
    - 10g checks the min and max values stored for columns in the data dictionary. If your predicates are way off compared to these values then 10g begins to adjust the calculated selectivity of the predicate which can again significantly affect your execution plans
    - 10g introduces the "Cost Based Query Transformation (CBQT)" feature which means that rather than applying heuristic transformation rules transformations are costed and potentially discarded whereas 9i applies transformations unconditionally whenever possible
    Check also the following note resp. white paper:
    http://optimizermagic.blogspot.com/2008/02/upgrading-from-oracle-database-9i-to.html
    Regards,
    Randolf
    Oracle related stuff blog:
    http://oracle-randolf.blogspot.com/
    SQLTools++ for Oracle (Open source Oracle GUI for Windows):
    http://www.sqltools-plusplus.org:7676/
    http://sourceforge.net/projects/sqlt-pp/

  • Performance problem after upgrade from Web version to Basic version

    A couple days I ago I 'upgraded' my SQL Azure database from the Web service tier to Basic. Since doing that the performance on many of my queries as dropped noticeably. I've made no schema changes, and the amount of data in my database has changed very
    little since the upgrade. Has anyone had this same problem?
    Randy Minder

    Randy,
    See this blog about how to upgrade to the new tiers and some advice on finding the right fit.
    http://azure.microsoft.com/en-us/documentation/articles/sql-database-upgrade-new-service-tiers/
    Basic is not equivalent to Web in the new Editions tiers. While you do 'upgrade' to editions, granting you access to new features and the tiers themselves, you can now choose an experience which has less performance than you had previous in Web/Business.
    Try upgrading your server to a new tier based on the advice in the article above. If you read the article below:
    https://msdn.microsoft.com/en-us/library/azure/dn369873.aspx
    You can see that standard is actually targeting at many of the production use cases of Web, where Basic is targeting developers who were using Web, before, to test out their applications. Basic isn't intended for scenarios with multiple concurrent users.
    Hopefully that helped. If you have any other questions, feel free to reply.
    Regards,
    Chris

  • Query Performance problem after upgrade from 8i to 10g

    Following query takes longer time in 10g.
    SELECT LIC_ID,FSCL_YR,KEY_NME,CRTE_TME_STMP,REMT_AMT,UNASGN_AMT,BAD_CK_IND,CSH_RCPT_PARTY_ID,csh_rcpt_id,REC_TYP,XENT_ID,CLNT_CDE,BTCH_CSH_STA,file_nbr,
    lic_nbr,TAX_NBR,ASGN_AMT FROM (
    SELECT /*+ FIRST_ROWS*/
         cpty.lic_id,
    cpty.clnt_cde,
    cpty.csh_rcpt_party_id,
    cpty.csh_rcpt_id,
    cpty.rec_typ,
    cpty.xent_id,
    cr.fscl_yr,
    cbh.btch_csh_sta,
    nam.key_nme,
    lic.file_nbr,
    lic.lic_nbr,
    cr.crte_tme_stmp,
    cr.remt_amt,
    cr.unasgn_amt,
    ee.tax_nbr,
    cr.asgn_amt,
    cr.bad_ck_ind
    FROM lic lic
    ,csh_rcpt_party cpty
    ,name nam
    ,xent ee
    ,csh_rcpt cr
    ,csh_btch_hdr cbh
    WHERE 1 = 1
    AND ee.xent_id = nam.xent_id
    AND cbh.btch_id = cr.btch_id
    AND cr.csh_rcpt_id = cpty.csh_rcpt_id
    AND ee.xent_id = cpty.xent_id
    AND cpty.lic_id = lic.lic_id(+)
    AND (cpty.clnt_cde IN ( SELECT clnt_cde
    FROM clnt
                   START WITH clnt_cde = '4006'
    CONNECT BY PRIOR clnt_cde_prnt = clnt_cde)
    OR cpty.clnt_cde IS NULL)
    AND nam.cur_nme_ind = 'Y'
    AND nam.ent_nme_typ = 'P' AND nam.key_nme LIKE 'WHITE%')
    order by lic_id
    Explain Plan in 8i
    0 SELECT STATEMENT Optimizer=HINT: FIRST_ROWS (Cost=17 Card=1
    Bytes=107)
    1 0 FILTER
    2 1 NESTED LOOPS (Cost=17 Card=1 Bytes=107)
    3 2 NESTED LOOPS (Cost=15 Card=1 Bytes=101)
    4 3 NESTED LOOPS (OUTER) (Cost=13 Card=1 Bytes=73)
    5 4 NESTED LOOPS (Cost=11 Card=1 Bytes=60)
    6 5 NESTED LOOPS (Cost=6 Card=1 Bytes=35)
    7 6 INDEX (RANGE SCAN) OF 'NAME_WBSRCH1_I' (NON-UN
    IQUE) (Cost=4 Card=1 Bytes=26)
    8 6 TABLE ACCESS (BY INDEX ROWID) OF 'XENT' (Cost=
    2 Card=4649627 Bytes=41846643)
    9 8 INDEX (UNIQUE SCAN) OF 'EE_PK' (UNIQUE) (Cos
    t=1 Card=4649627)
    10 5 TABLE ACCESS (BY INDEX ROWID) OF 'CSH_RCPT_PARTY
    ' (Cost=5 Card=442076 Bytes=11051900)
    11 10 INDEX (RANGE SCAN) OF 'CPTY_EE_FK_I' (NON-UNIQ
    UE) (Cost=2 Card=442076)
    12 4 TABLE ACCESS (BY INDEX ROWID) OF 'LIC' (Cost=2 Car
    d=3254422 Bytes=42307486)
    13 12 INDEX (UNIQUE SCAN) OF 'LIC_PK' (UNIQUE) (Cost=1
    Card=3254422)
    14 3 TABLE ACCESS (BY INDEX ROWID) OF 'CSH_RCPT' (Cost=2
    Card=6811443 Bytes=190720404)
    15 14 INDEX (UNIQUE SCAN) OF 'CR_PK' (UNIQUE) (Cost=1 Ca
    rd=6811443)
    16 2 TABLE ACCESS (BY INDEX ROWID) OF 'CSH_BTCH_HDR' (Cost=
    2 Card=454314 Bytes=2725884)
    17 16 INDEX (UNIQUE SCAN) OF 'CBH_PK' (UNIQUE) (Cost=1 Car
    d=454314)
    18 1 FILTER
    19 18 CONNECT BY
    20 19 INDEX (UNIQUE SCAN) OF 'CLNT_PK' (UNIQUE) (Cost=1 Ca
    rd=1 Bytes=4)
    21 19 TABLE ACCESS (BY USER ROWID) OF 'CLNT'
    22 19 TABLE ACCESS (BY INDEX ROWID) OF 'CLNT' (Cost=2 Card
    =1 Bytes=7)
    23 22 INDEX (UNIQUE SCAN) OF 'CLNT_PK' (UNIQUE) (Cost=1
    Card=1)
    Explain Plan in 10g
    0 SELECT STATEMENT Optimizer=HINT: FIRST_ROWS (Cost=19 Card=1
    Bytes=112)
    1 0 SORT (ORDER BY) (Cost=19 Card=1 Bytes=112)
    2 1 FILTER
    3 2 NESTED LOOPS (Cost=18 Card=1 Bytes=112)
    4 3 NESTED LOOPS (Cost=16 Card=1 Bytes=106)
    5 4 NESTED LOOPS (OUTER) (Cost=14 Card=1 Bytes=78)
    6 5 NESTED LOOPS (Cost=12 Card=1 Bytes=65)
    7 6 NESTED LOOPS (Cost=6 Card=1 Bytes=34)
    8 7 INDEX (RANGE SCAN) OF 'NAME_WBSRCH1_I' (INDE
    X) (Cost=4 Card=1 Bytes=25)
    9 7 TABLE ACCESS (BY INDEX ROWID) OF 'XENT' (TAB
    LE) (Cost=2 Card=1 Bytes=9)
    10 9 INDEX (UNIQUE SCAN) OF 'EE_PK' (INDEX (UNI
    QUE)) (Cost=1 Card=1)
    11 6 TABLE ACCESS (BY INDEX ROWID) OF 'CSH_RCPT_PAR
    TY' (TABLE) (Cost=6 Card=1 Bytes=31)
    12 11 INDEX (RANGE SCAN) OF 'CPTY_EE_FK_I' (INDEX)
    (Cost=2 Card=4)
    13 5 TABLE ACCESS (BY INDEX ROWID) OF 'LIC' (TABLE) (
    Cost=2 Card=1 Bytes=13)
    14 13 INDEX (UNIQUE SCAN) OF 'LIC_PK' (INDEX (UNIQUE
    )) (Cost=1 Card=1)
    15 4 TABLE ACCESS (BY INDEX ROWID) OF 'CSH_RCPT' (TABLE
    ) (Cost=2 Card=1 Bytes=28)
    16 15 INDEX (UNIQUE SCAN) OF 'CR_PK' (INDEX (UNIQUE))
    (Cost=1 Card=1)
    17 3 TABLE ACCESS (BY INDEX ROWID) OF 'CSH_BTCH_HDR' (TAB
    LE) (Cost=2 Card=1 Bytes=6)
    18 17 INDEX (UNIQUE SCAN) OF 'CBH_PK' (INDEX (UNIQUE)) (
    Cost=1 Card=1)
    19 2 FILTER
    20 19 CONNECT BY (WITH FILTERING)
    21 20 TABLE ACCESS (BY INDEX ROWID) OF 'CLNT' (TABLE) (C
    ost=2 Card=1 Bytes=15)
    22 21 INDEX (UNIQUE SCAN) OF 'CLNT_PK' (INDEX (UNIQUE)
    ) (Cost=1 Card=1)
    23 20 NESTED LOOPS
    24 23 BUFFER (SORT)
    25 24 CONNECT BY PUMP
    26 23 TABLE ACCESS (BY INDEX ROWID) OF 'CLNT' (TABLE)
    (Cost=2 Card=1 Bytes=7)
    27 26 INDEX (UNIQUE SCAN) OF 'CLNT_PK' (INDEX (UNIQU
    E)) (Cost=1 Card=1)
    28 20 TABLE ACCESS (FULL) OF 'CLNT' (TABLE) (Cost=5 Card
    =541 Bytes=5951)
    Explain plan looks different in steps 19 to 28. I am not sure why 10g have more steps

    Hi
    I have no experience in 8i. I do know 10g does costing different from 8i. So I think the other plan might got elliminated.
    Normally when I see differences. I just collect statistics on the tables and the indexes and remove the hints. Hints are not good . This has helped me to solve few problems.
    Thanks
    CT

  • Spatial query performance problem after upgrade to 10G

    I am in the process of converting my database from a 9i box to a new 10G 64-bit box. But I have found a problem which is causing some reports to be slower on the new box. I have simplified the queries down to having the user_sdo_geom_metadata table joined to use the diminfo in the queries (I know that I am not using them in these queries, but I simplified for testing purposes...)
    If I run the following I get and look at the explain plan I get full table scans for both spatial tables and index lookups for the user_sdo_geom_metadata table queries and runs for about 14 seconds.
    SELECT ROWNUM
    from COUNTIES s,
    NOMINATIONS O,
    (select diminfo from user_sdo_geom_metadata where table_name='COUNTIES') S_DIM,
    (select diminfo from user_sdo_geom_metadata where table_name='NOMINATIONS') O_DIM
    where sdo_filter(S.GEOM,o.geom, 'querytype=WINDOW')='TRUE'
    and sdo_geom.within_distance(o.geom,0,S.GEOM,.5)='TRUE';
    If I just remove the two user_sdo_geom_metadata joins, I get spatial index usage on COUNTIES and the whole thing runs in less that a second.
    SELECT ROWNUM
    from COUNTIES s,
    NOMINATIONS O
    where sdo_filter(S.GEOM,o.geom, 'querytype=WINDOW')='TRUE'
    and sdo_geom.within_distance(o.geom,0,S.GEOM,.5)='TRUE';
    I have rebuilt the indexes, gathered stats, and tried hints to force the first query to use the spatial index. None of which made any change.
    Has anyone else seen this?
    Gerard Vidrine

    Hi Gerard,
    When the query window comes from a table Oracle always recommends:
    1) Use the /*+ ordered */ hint
    2) Put the table the quiery window comes from (geometry-2 in the query) first in the from clause
    However, your query is also written very strange. Do you know about SDO_WITHIN_DISTANCE? Or are you trying to do SDO_ANYINTERACT (since the distance is 0)?
    So I would write the query you have as:
    SELECT s.ROWNUM
    from NOMINATIONS O, COUNTIES s
    where sdo_relate(S.GEOM,o.geom, 'querytype=WINDOW mask=anyinteract')='TRUE';
    or in Oracle10g:
    SELECT s.ROWNUM
    from NOMINATIONS O, COUNTIES s
    where sdo_anyinteract(S.GEOM,o.geom)='TRUE';

  • A tough performance problem after upgrade to 10g

    A stored procedure is running fine (returns in 2 min) against SQLPLUS. But when it is called from the application interface, it will take 40 min to return. I have traced the session and found there is one query takes most of the time waiting on 'db file sequential read', 'gc cr grant 2-way', 'gc cr block 2-way', etc. Is there something needs to be tuned from the database point of view. I cannot explain why it's running perfect in SQLPLUS.

    Are the query plans the same when the procedure is called from SQL*Plus and when it is called from the application?
    What proportion of the wait time is attribued to the "gc cr grant 2-way" and "gc cr block 2-way" events? Those are events caused by cache fusion in Oracle RAC-- is it possible that the application is running on a different node than your SQL*Plus session? If those events are a significant fraction of the overall wait time, that implies that some other instance has the block pinned. Do you have a handful of hot blocks that have to get sent between different instances constantly?
    Justin

  • Problems after upgrade bios to v4.3 - P67A-GD65

    Hi to everybody,
    I was having a problems after upgrade bios to v4.3 of my mainboard P67A-GD65.
    After upgraded bios version (FW) its interface was changed and seemed better. also some specifiactions upgraded that i am now able to follow information of bios in my windows. with Control Center.
    1) first of all after bios upgrade XMP memory section can only be enable şf ş choose OC geniue on. but with this my cpu warm till 98C degree. because i have only stock cpu cooler of intel.
    in normal mode xmp can not be activated so that my memory that corsair vengeance dd3 1600mhz works at 1333mhz only.
    Also there was information about what is new in this version of bios fw as:
    - Enhanced PCI-E display card performance.
    - Improved memory compatibility.
    2) second problem that i have i wanted to turn cpu leds which were located above cpu slot blue leds. once i turn them off and it is ok. but when shutdown computer and restart it turn on itself.
    so may be there have benn occured a problem that mb can not save edited settings correctly?
    3) For last i could not find Winki 3 OS/linuz anywhere is there a link to it to integrate to my mb?
    Thanks for your replies from now on.
    Greetings.

    Quote from: momosala on 02-April-13, 17:54:22
    I think you had better to flash back to beta 4.39 bios, here : https://forum-en.msi.com/index.php?topic=164135.msg1214789#msg1214789
    And use and install on USB key MSI Forum HQ USB flashing tool from here : https://forum-en.msi.com/index.php?topic=108079.msg800577#msg800577
    Flash using method 1.
    And tell us if that works.
    thank you for reply that fast i will try asap and tell here.
    Btw, have you ever face a problem as i wrote above?

  • Problems after upgrade: Leopard to Leopard no longer works

    My sister upgraded to Leopard on her iMac(c2d) to Leopard yesterday. Earlier in the day we were able to do video chats with a number of people(her machine Tiger to Fathers machine Leopard). However, since upgrading, we've experienced weird behavior for video chats. Basically in her window she won't see her image(the small one), and I don't see her at all. We've tested this out with a number of other iChat accounts and get the same results. Btw, all machines that are chatting with her are using Leopard. Also, all other forms/capabilities work: screen sharing, sharing of pictures, audio chats.
    Anyone out there have similar problems after upgrading from Tiger to Leopard? I have done the usual adjustments of bandwidth and QT settings, as well as restarts. What else should I try?
    tia,
    n

    I finally resolved this problem: I think the issues/steps would be helpful for anyone who experiences iSight off or not working problems after upgrading to Leopard(then to 10.5.1) on a intel 20" iMac :
    Problem:
    -If you have an internal iSight on an iMac and your camera works fine in Tiger
    -If you upgrade to Leopard
    -If Chat camera doesn't show your image (iSight off) even though the green light is on
    -You can see the other persons video on iChat
    -Your friends can here you and you can share screens, files, etc.....everything but have them see you
    These are the initial steps I took:
    - Deleted the pLists(or stored preferences for the Application) described at the top of this thread
    - Was told it might be slow internet connection so did various things: disconnected other computers, changed wireless to "G" only
    - Specifically Opened of ports spec'd for Leopard on router (even though I hadn't needed to do this under Tiger)
    - Tried chats with various people on various fast/slow networks
    - Restarted all aspects of the network: router, wireless access point, computer
    - Checked to see if the iSight was shown in 'System Profiler'. It was found in 'About This Mac->More Info->System Profiler->USB'
    - Clicked Video icon in iChat Buddies window(to the right of your name) and coudn't see my image
    - Opened 'PhotoBooth' and coudn't see my image(black screen)
    - Opened iMovie and couldn't capture video via the iSight(black screen)
    - Opened iChat->Preferences->Video and couldn't see my image
    - Validated that 'Camera is Enabled' in iChat->Video->Camera is Enabled
    If you are experiencing a similar problem with you built-in iSight, I would probably focus on the last 5 things that I did. What they showed me was that the iSight was just not capturing video even though it was capturing sound in 3 different applications.
    The solution to iSight Off or iSight Not Responding or No Video is......reset your computer! I had thought my sister performed this but it turns out she hadn't. Here's the link to this procedure:
    http://docs.info.apple.com/article.html?artnum=303446
    Very easy to do though: Power off computer and unplug all cables, including power cable for at least 15 seconds. Plug everything back in and power up the computer and retry clicking on the 'Video' icon next to your login name. If you see yourself then...problem is solved.
    While I eventually found posts in several other forums, it took me the better part of a week. To try this simple step. I wish I had done so straight away. Oy. I guess I learned a lot about ports, speed etc.
    I hope this helps.

  • Performance issue after Upgrade from 4.7 to ECC 6.0 with a select query

    Hi All,
    There is a Performance issue after Upgrade from 4.7 to ECC 6.0 with a select query in a report painter.
    This query is working fine when executed in 4.7 system where as it is running for more time in ECC6.0.
    Select query is on the table COSP.
    SELECT (FIELD_LIST)
            INTO CORRESPONDING FIELDS OF TABLE I_COSP PACKAGE SIZE 1000
            FROM  COSP CLIENT SPECIFIED
            WHERE GJAHR IN SELR_GJAHR
              AND KSTAR IN SELR_KSTAR
              AND LEDNR EQ '00'
              AND OBJNR IN SELR_OBJNR
              AND PERBL IN SELR_PERBL
              AND VERSN IN SELR_VERSN
              AND WRTTP IN SELR_WRTTP
              AND MANDT IN MANDTTAB
            GROUP BY (GROUP_LIST).
       LOOP AT I_COSP      .
         COSP                           = I_COSP      .
         PERFORM PCOSP       USING I_COSP-_COUNTER.
         CLEAR: $RWTAB, COSP                          .
         CLEAR CCR1S                         .
       ENDLOOP.
    ENDSELECT.
    I have checked with the table indexes, they were same as in 4.7 system.
    What can be the reson for the difference in execution time. How can this be reduced without adjusting the select query.
    Thanks in advance for the responses.
    Regards,
    Dedeepya.

    Hi,
    ohhhhh....... lots of problems in select query......this is not the way you should write it.
    Some generic comments:
    1. never use SELECT
                       endselect.
       SELECT
      into table
       for all entries in table
      where.
       use perform statment after this selection.
    2. Do not use into corresponding fields. use exact structure type.
    3. use proper sequence of fields in the where condition so that it helps table go according to indexes.
        e.g in your case
              sequence should be
    LEDNR
    OBJNR
    GJAHR
    WRTTP
    VERSN
    KSTAR
    HRKFT
    VRGNG
    VBUND
    PARGB
    BEKNZ
    TWAER
    PERBL
    sequence should be same as defined in table.
    Always keep select query as simple as possible and perform all other calculations etc. afterwords.
    I hope it helps.
    Regards,
    Pranaya

  • I have problems after upgrade my firefox

    I have problems after upgrade my firefox
    <i>(Suspected spam link removed by Moderator. Please read the [[Forum rules and guidelines]] -m)</i>

    Hey there Noel,
    It sounds like you are unable to activate your iPhone after you reset it. I recommend the steps from the following article to help you get that resolved:
    Get help activating your iPhone
    If your carrier provided a SIM card, make sure it's in your iPhone.
    Restart the iPhone.
    Try to reach the activation server another way, then try to activate.
    Try connecting to a known-good Wi-Fi network if you can't activate using a cellular data connection.
    Try connecting to iTunes if you can't activate using Wi-Fi.
    Restore the iPhone.
    Check the system status for iOS Device Activation. If the iOS Device Activation status isn't green, try activating your iPhone later.
    If you receive an alert message when you try to activate your iPhone, place the iPhone in recovery mode and perform a restore. If you still can't complete the setup assistant due to an activation error, contact Apple for assistance.
    Thank you for using Apple Support Communities.
    All the best,
    Sterling

  • Problems after upgrading to iTunes version 6

    Hello,
    I've been going through the threads a lot since I have had problems after upgrading to iTunes v. 6. It looks like a lot of people have had the same issues, and I have tried some things that were recommended. After I upgraded, iTunes would not open. I tried:
    1. deleting sidb file
    2. doing the msconfig thing suggested in discussion boards
    3. going into safe mode and deleting 4 and 6 letter weird files in DOS - I found 3 that I deleted
    iTunes worked after this -- then I bought a song and it said my computer was not authorized, after I authorized computer (that never happened before), iTunes worked for about 15 more minutes and then closed down abruptly. I haven't been able to open it since.
    I also downloaded Spybot search & destroy and that did not find anything. I am using McAfee, and have scanned for viruses with McAfee and AdAware.
    Now, when I restart my computer, a bunch of windows pop up with Chinese/Japanese looking characters and say that device (I think) was not found. I seem to be able to use everything except iTunes and Quicktime. When I open the Task Manager, iPodService.exe and iTunesHelper.exe and qttask.exe are there, but when I click on Quicktime or iTunes the file flashes in Task Manager and then disappears.
    I'm not sure where to go from here.
    Any help would be apppreciated -- I'd like to be able to open iTunes!

    Hello,
    I used Nickroo's post:
    I was able to get iTunes launched (with the help of Tech Support) in a very unsafe environment. I owe it to those who may need this after me. It will get you going, but you will be extremely vulnerable to internet virus assaults. Please do not use this approach, until you have exhausted every other available solution for your issue in the KB.
    There are three Steps 1) Uninstall 2) Disble and 3) Reinstall.
    UNISTALL Uninstall iTunes using Windows utility Add Remove Program available in Control Panel.
    DISABLE Disable all third party System Services and Startup Items using using MSCONFIG utility as described in Service Document http://docs.info.apple.com/article.html?artnum=302538
    RE-INSTALL Re-install iTunes6 + QT7. Launch it under the Selective Startup Option.
    It worked ! You realize among other things at this point you have your Antivirus and Firewall disabled. When I started my computer in the Normal Startup Option, iTunes fails to work again. So I have ahead of me the long and ardous task of ruling out the service that is causing conflict with iTunes6. Then work with the software vendor to arrive at a solution.
    This seems to have worked so far- I haven't started to go through ruling out what made iTunes not work; I also haven't tried to connect my iPod or burn a CD, so we'll see.
    Windows XP

  • Permission problems after upgrade to 10.5 on early Power PC G5 Tower

    Permissions problems after upgrading to 10.5 on a client power PC (early) G5 tower.
    Problems include folders that are created on XServe via this client do not allow any one else including this client to access. All other clients running 10.5, which happen to be newer Intel machines do not have this problem. Repairing permissions, updating to 10.5.1, try to manually correct permissions have all failed to repair the situation. All clients log onto the XServe with the same user/password. This client has since been downgraded back to 10.4.9 and has no issues.
    The Xserve runs 10.3.9, any help would be greatly appreciated.
    We have read through the forums regarding permission problems after upgrading and even tried some tips found here.

    You really should check things out first before speaking.
    Here are the requirements for 10.5;
    Mac OS X v10.5 Leopard requires:
    A Mac computer with an Intel, PowerPC G5, or Power PC G4 (867 MHz or faster) processor
    512 MB memory or more
    A DVD drive for installation
    9 GB of available disk space or more
    Some features require a compatible Internet service provider, fees may apply.
    Some features require Apple's MobileMe service; fees apply.
    Allan

  • Layouts problem after upgrade

    Hello, I have a problem after upgrade from 2007 to 8.81 PL 05.
    Since we upgrade SAP, the layout changed.
    For example, in a credit note if it has 3 lines, in the layout will appear 2 lines in a page and 1 in other page.
    if the credit note has 4 lines, in the layout will appear 3 lines in a page and 1 in other page.
    What could it be?
    Thanks in advance.

    Hi!
    lines are not duplicated, they just printed on different pages:
    - if doc has just 2 lines  -  printed form is good
    - if doc has 3 items, two of them are printed on the first page, 3d - on the second page
    - if doc has 4 items, 3 of them are printed on the first page, 4th - on the second page
    When we are printing directly from the server everything is working fine. But printing from all Clients gives us this issue that is described above.
    SAP re-installation  for all users will take too much time. May be exist any other option that we can try?
    we really appreciate your help
    Natalia

  • Problem after upgrading to ICS 4.0.4

    i have different problem after upgrading my SE Live with Walkman to ICS 4.0. After upgrading, my sd card always full. I have try to remove some files but after that it full again. Finaly i found that there are tumbnail file with size precisely same with my empty space. I delete that file, but the empty space not recover, its only recover after unmounting sd card. But its not hold for long time, after one minutes its happen again, my sd card is back fully again, and the same file is back to exist. Please help me, is that a virus or bugs from ICS?? i very frustation with this case
    thanx for your help

    Do you have many pictures?
    Have your tried to reinstall the phone software using SUS to check if the problem remains?
    http://www.sonymobile.com/gb/tools/update-service/
     - Community Manager Sony Xperia Support Forum
    If you're new to our forums make sure that you have read our Discussion guidelines.
    If you want to get in touch with the local support team for your country please visit our contact page.

Maybe you are looking for

  • Trying to host comic blog

    The linked image best explains my question. Basically I want to make the blog preview images larger... http://img126.imageshack.us/img126/1408/iwebquestionyu9.gif PowerBook G4   Mac OS X (10.4.4)  

  • PSE 8.0 Contact List disappeared

    I use Windows 7 and have installed PSE 8.0. I am also using Windows Live Mail for e-mail. When trying to share photos, PSE has worked until yesterday. The entire contact list has simply disappeared- apparently deleted. Also, now when I am in the Orga

  • Java.sql.SQLException: ORA-03135: connection lost contact

    In the whesphere portal i foun a lot of "ORA-03135: connection lost contact" errors but i cant find this error in the oracle client or oracle database. Oracle Client 10.2.0.1 Oracle RDBMS 10.2.0.3 -- in Rac with 3 nodes I have a fragment of the trace

  • How to remotely deploy adf application using ant script

    Please suggest some pointer on how to remotely deploy adf application using ant script. I have created automatic inbuild ant script using jdevloper and ojdeploy that create a war file into my adf application deploy folder. Now i want my war to be dep

  • How to set view

    Hi all I have two tables xxxx and yyyy both having same columns name with same data types but values are different I have search page want to search based on that two tables values I want all values from two tables for that purpose I have created a v