Phantom Assembly Reporting Point Backflush - Not able to backflush

We are unable to generate a backflush of the assembly components of a phantom assembly.  The backflush indicator in the operation have been activated and the components involved are production relevant.
In the material master, i believe the REM Profile has been set correctly to allow for backflushing of the asseblies.
Am I overlooking something to have this work properly? 
Any thoughts are much appreciated!
Thanks All!

Dear suntevea,
Generally Production confirmation is not made for phantom assemblies either in Discrete or REM scenario.
So once when you do the confirmation for the upper level assembly where this phantom assembly is used
as a component,then at this point the good's issue(backflush) will be happening for the component's of the
phantom assembly.
Eg : Material A is a phantom assembly which is made up of components say B & C.
Again material A is a component for making another assembly say X,so when you do the backflushing in
MFBF for material X,you can see the components B & C are getting issued,which means Good's issue will
be happening for B & C,261 movement.
I hope you will be clear with the concept.
Revert back if you need any further assistance.
Regards
Mangalraj.S

Similar Messages

  • Report Designer: Text not able dispaly in the report

    Hi,
    Am using Report Designer with the variable 0FISPER,when user select the period like Period 12 2007 then in the Report it should Display as December 2007(as Header).I tried maintained Text to that variable and also maintained text in the SPRO for the table t009c.Here when i maintain text in the table(t009c) in the variable i can see only jan, feb,...........Dec when  i select in the pop up window say Jan  in the report it display only Jan but not the year.
    We are in SP15
    Thanks=Points in SDN
    Sanjeev

    It sounds like that your Web CGI did not configure right. To test if your CGI configuration is correct, type:
    http://hostname:port/cgi-bin/rwcgi60exe?
    If you get a help screen, then you should be able to bring up your report.
    Regards,
    Xiaoling

  • Report 6i/Webdb -Not able to display the report in the browser - rep- 3002 error.

    Would someone tell what I missed, I have set up the following:
    1) a report using report builder on NT
    2) my database is in Unix
    3) my report server is started in NT
    4) I run webdb listener for the following code: http://myweb.com/cgi/rwcgi60.exe?server=repserver+report=myreport+userid=usid/pw/connect_string+destype=cache+desformat=html. Then, I receive this message:
    Error: The requested URL was not found, or cannot be served at this time.
    Oracle Reports Server CGI - Report Job has terminated with error.
    Reports Server Replies:
    REP-3002: Error initializing printer. Please make sure a printer is installed.
    Why is it thinking I want to use the printer whereas I want to display the report in the browser?. Any help would be appreciated.
    null

    It sounds like that your Web CGI did not configure right. To test if your CGI configuration is correct, type:
    http://hostname:port/cgi-bin/rwcgi60exe?
    If you get a help screen, then you should be able to bring up your report.
    Regards,
    Xiaoling

  • DataSource at Report Server is not able to connect another server

    Hi All,
    I am having two servers on different Domain; One where my default SQL 2012 database Instance is present (say: Server 1), and another server where Report Server 2012 is installed (say Server 2).
    From Management Studio, I am able to connect database server 1 from server 2. Even I am able to Ping server 1 from server 2.
    But when I am creating Data Source at Report Server (Server 2), to connect Database Server (Server 1), I am getting below error:
    "A network-related or instance-specific error occurred while establishing a connection to SQL Server. The server was not found or was not accessible. Verify that the instance name is correct and that SQL Server is configured to allow remote connections.
    (provider: Named Pipes Provider, error: 40 - Could not open a connection to SQL Server)"
    I using below connection string in Data Source:
    Data Source=SERVER1;Initial Catalog=msdb
    Below are the additional information:
    Server Instance Protocols on Server 1: Named Pipe, TCP/IP and Shared Memory are Enabled
    SQL Services on Server 1: SQL Server, SQL Browser are running
    Please help me on this.
    Thanks ,
    Avi
    -Regards Avi | Please kindly don’t forget to mark the post(s) that answered your question

    Are you really connecting to the msdb database in your connection string?  What is the user you are connecting to the database as when you are in Management Studio?  Is it an SQL user or a Windows user?  Maybe whatever credentials you are
    using in your datasource does not have access to the sql server?
    And is it Server 1 or Server1? or is that just an example server name.  I agree with trying the ip address but make sure you are using the same credentials as you do in Management Studio

  • Reporting services instance not able to connect from SSMS

    Hi All,,
    I have installed SQL SERVER 2012 on Windows 8.1. I configured report server in native mode.
      * Reporting services is in started state
      * SQl server service is in started state
      * Sql serevr agent is in started state
      * SQL browser is in started state
    When i tried to connect Report server instance using SSMS i got the below error.
    TITLE: Connect to Server
    Cannot connect to .
    ADDITIONAL INFORMATION:
    Unable to connect to the server at . The specified URL might not be valid or there might be a problem with the report server version or configuration. Specify a different URL, or contact your server administrator to verify that the report server runs SQL Server
    2008 or later. Additionally, if you are trying to connect to a SharePoint-integrated report server, verify that SharePoint is installed on the server and that the report server uses SharePoint integrated mode. (Microsoft.SqlServer.Management.UI.RSClient)
    BUTTONS:
    OK
    When i connect using http://localhost/reportserver I am getting below error
    The permissions granted to user '' are insufficient for performing this operation. 
    Though i am the administrator 
    And when i connect using below URL http://localhost/reports 
    I get Unable to connect to the remote server 
    Please suggest your input on the problem

    Hi Khushi N,
    According to your description, you are administrator, when you tried to connect reporting services from SSMS, the error message occurred. When you tried to access report manager with the URL: 
    http://localhost/reportserver, you were prompted that the permissions granted to user '' are insufficient for performing this operation.
    The Reporting Services error rsAccessedDenied occurs when a user does not have permission to perform an action. To troubleshooting this issue, please make sure that you have sufficient permission and the report server name is correct. You can use the reportserver
    URL, e.g. HTTP ://<servername>/ReportServer, to log on the reporting service in SSMS.
    In addition, by default, we could not access all of the report server properties available in SQL Server Management Studio unless we start Management Studio with administrative privileges. To configure Reporting Services role properties and role assignments
    so you do not need to start Management Studio with elevated permissions each time, please refer to the following document:
    From the Start menu, click All Programs, click SQL Server 2012, right-click Management Studio, and then click Run as administrator.
    Connect to your local Reporting Services server.
    In the Security node, click System Roles.
    Right-click System Administrator and then click Properties.
    In the System Role Properties page, select View report server properties. Select any other properties you want associated with members of the system administrators role.
    Click OK.
    Close Management Studio
    The issue may be caused by the UAC or Internet Explorer security setting, please try to follow this steps:
    1. Open the Internet options of the IE and add the report server URL into trusted site in the Security tab.
    2. Run the IE as administrator.
    For more information about Configuring a Native Mode Report Server for Local Administration, please refer to the following document:
    http://msdn.microsoft.com/en-us/library/bb630430(v=sql.110).aspx
    If you have any more questions, please feel free to ask.
    Thanks,
    Wendy Fu

  • Manual reorder point  planning not able to create

    Dear all,
    I am maintaining  manual reorder point planning for one raw material  with MRP type  VB and  also maintained reorder point level . For other two raw materials  i am maintaining  MRP type as  PD  my issue  is
    when ever  i run MRP for FG material  purchase requisition is not generating for the material with MRP type VB even though stock is less than Reorder point. For other two raw materials  purchase requisitions are generated 
    Pls give me solutions for  generating the purchase requisitions  for the raw material with MRP type  VB.
                                                                Thanks
                                                                 MBR

    please check here:
    http://help.sap.com/saphelp_47x200/helpdata/en/f4/7d256344af11d182b40000e829fbfe/frameset.htm

  • Not able to see the data in the report

    Hi All
          In my cube i am having data.But when i am running the report ,i am not able to see the data.
        The error its throwing is -No Applicable data found.
        what could be the problem,please provide me the idea to solve the problem.
    Thanks&regards
    syam prasad dasari

    HI,
    See that any restrictions are there in the report(Filters)....Give the same restrictions in Listcube and see if you are getting data or not.....
    Thanks

  • Planned order is not creating for a phantom assembly

    Dear experts
    My fert having two semi finished components
    first semifinished is assigned with a raw material
    And second semifinished is assigned with two different raw material
    in material master of second semifinished mrp2 view Special procurement=50
    and after running mrp, second semifinished is not getting any planned order or dep requirement all the raw material under this getting planned order
    But in my understanding of phantom second semifinished in should not get any planned order?
    Am  i correct?
    Pls advise me where i need to check
    Abu Fathiam

    Hi,
    Phantom assembly will generate planned order for its component when you will maintain:
    Procurement type: E
    Special procurement type: 50
    Also in SPRO: OPPQ BOM explosion
    Also check in BOM In basic data tab
    In MRP Data screen, check explosion type- are you maintained phantom assembly off? Check it if you want planned order.
    If you don't want system generated planned order for your phantom assembly component you should not maintain this indicator.
    Regards,
    Alok Tiwari
    Edited by: Alok Kumar Tiwari on Feb 29, 2012 11:38 AM
    Edited by: Alok Kumar Tiwari on Feb 29, 2012 11:39 AM

  • Resetting of reporting points

    Dear Gurus,
    I am facing problem in resetting of reporting points .
    We have created product cost collector with production version but at that time REM allowed indicator is not ticked and control key is with out milestone confirmation
    Transaction are done with  reporting point 10 & reporting point 20 i have checked in table S028 & CEZP,CPZP all entries are available but in Tcode MF12  all entries are not available
    we iam try set reporting points in MF4R The production version is not available for this i have ticked REM allowed indicator & Mile stone confirmation in control key it shows in MF4R But both the reporting points with O quantity.
    As per S028 table my quantity differs in Reporting point 10 & 20
    i have backflush some qty for reporting points 10 & 20 but it consider NEW QTY for resetting OLD QTY.
    we have upgrade from 4.6 to 6.0 two years back.
    we are using Period end closing process now.
    i want to reset alI WIP of old PCC  to REL Scrap by using MF4R.
    I Have RE set all  PCC by MF4R  but this is my old PCC it creates me problem in restting
    There is any way to reduce WIP to zero in old PCC Cost collectors with out resetting reporting points
    Already we run  report KKAO
    I have checked all below notes
    SAP Note 756186 - RM402 No reporting points when creating
    production version  - available
    MFBF: Reporting point backflush
    terminates with error RM111
    Any program, Any note for to reset WIP TO zero
    Regards
    Avinash

    hi experts,
    Any one can resolve my problem
    please revert back for any clarification required
    Regards
    Avinash

  • Reporting points - REM

    Hai PP Experts!!
               I created reporting points in rate routing by assiging the control key with milestone confirmation.But in the MFBF screen during reporting point selection system shows error "reporting points are not maintained in PCC" . I also maintained suitable REM Profile (ie., i activated RP in the profile)
               So pls throw some light on creation of reporting points, required customization and sequence of steps....
    Advace thanks.............
    Ganeshraja

    Dear Mr.Ganesh raja,
    Check in customizing-Control data for REM profile under control data 1,whether GI backflush at GR posting,if it's so deselect that and select RP backflush,then only the system allows you to use RP backflush.
    You have to assign the same REM profile for the material which you want to use RP backflush.
    And also in MFBF,plz include a tick mark in RP backflush field.
    <b>If useful reward points.</b>
    Regards
    Mangal

  • Not able to catch the exception

    Hi,
    I'm trying to run an ADF page (Test.jspx) . The only page content I have is an embedded BI report.
    I have used a report executable in my page definition.
    A sample code snippet is:
    <executables>
    <biContent id="biExecBinding1" connectionId="TMBIPresentationServerConn" path="/shared/TMSharedFolders/MOT_SalesAccount" type="biReportContent" xmlns="http://xmlns.oracle.com/bi/report/bindings">
    </executables>
    Here TMBIPresentationServerConn is the name of the connection of the BI Server.
    If BI Server is down, on running my page , an exception is being thrown by the framework.
    I want to catch this exception and perform my own logic, but since i am using a binding context for report , i am not able to catch this exception.
    Could you please let me know how can i catch the exception if BI is down?
    Thanks
    Nutan

    (as I suspected from your first post)
    You are using a version of JDeveloper that isn't available to the general public, and are asking about it on a public forum. You should use the internal Oracle forum - I don't know the URL, because I am one of the unwashed general public ;)
    John

  • PCA document not able to display in tc: 9KEK

    Hi,
    I have posted some entries in PCA via allocation and also adjustment entries.
    I am able to see these entries in GLPCA table and also in standard line item report: KE5Z but not able see the document in PCA document display transaction 9KE9, I have selected the layout, doc number, document type.
    Any help on this.
    Thanks
    Suresh

    If you assign the profit center in the document or it will be posted dummy profit center automatically,based on cost objects assignment to the profit center.kinldy check once again in the profit center master data.If you posted the document pertaining to the profit center, it shows in the report KE5Z.
    Please check in the master data and document.
    Thanks and regads
    Sivakumar.Subbiah

  • Not able to update organizations units in an infotype 0001

    Iam unable to update organizational units, positions through lsmw in an infotype 0001 if i do manually it is updating in 1infotype.
    Iam trying to run reports rhinteoo still not able to figure it out
    experts share your experience on this

    Ran LSMW Record created successfully for position
    If I see in organizational Assignment Infotype The record is not displaying
    As per your email Iam trying reports to display organizational units for the positions
    RHINTE10
    Done Livrun
    Next step RHINTE20
    My position is not in the list that is 600450
    Executed RHINTE30 I wonder how do we come to know personnel number when we are recording positions and organizational units. Still i checked personnel number in organizational assignment infotype and executed but it is displaying No batch input folder created . Yes we didnt create any batch input for personnel  numbers we created batch input for positions and org units.
    I believe we need to run first two records
    After running above reports i checked in an organizational assignment Infotype . Still data is not updating what would be the cause please let me know

  • Phantom assembly BOM

    Hi All,
    My client has the following setup:
    They have a BOM for the Finished product (Sub Contract BOM) but one item is a phantom assembly which has it's own BOM.
    In there current system they only use BOM usage 1 for production. In the upgrade system we use production and sub con BOM usage.
    Any recommendation as to what usage to use for the phantom BOM?
    Sub con or production?
    Thanks
    Stuart

    Hi Stuart,
    It's usage should be production,  as BOM item is a phantom assembly, the dependent requirements of the higher-level assembly are directly passed on to the components of the phantom assembly. The phantom assembly itself is still not taken into account.
    Why do you want to use sub-con usage?
    Regards,
    R.Brahmankar

  • The reporting point backflush is not possible for make-to-stock repetitive

    Hi All,
    we are using the assembly backflush in the MTS REM process. we are need to do the reporting point backflush
    if we tick against the RP backflush. what will be the effect in the process while confirmation.
    i read the sap library . it say like
    The reporting point backflush is not possible for make-to-stock repetitive manufacturing.
    is it correct.
    Thanks
    VRaj

    Hi mangal,
    i did all the setting as you said. but when click on the reporting point.
    system thru error
    Error reading reporting point information
    Message no. RM111
    Diagnosis
    The repetitive manufacturing profile is set for the reporting point procedure. However, either no reporting points exist for the material or they are incorrect. Two common reasons for this are:
    The repetitive manufacturing profile has been changed in the current session.
    You have not defined any milestone operations in the routing.
    When creating the product cost collector, no reporting points were created.
    Procedure
    Two alternative solutions are possible:
    Assign a repetitive manufacturing profile with no reporting point procedure to the material in the material master record.
    Recreate the reporting points by recosting the product cost collector. To do this, the following prerequisites must be met:
    In the material master record, in the production version, you must enter a routing under either detailed planning (first priority) or under rate-based planning (second priority).
    Milestone operations must exist in this routing. The system ususally automatically creates the reporting points from these milestones when creating a product cost collector or when creating a production version.
    how to create the REPORTING POINT

Maybe you are looking for

  • Trying to delete iPhoto 6 thumbsegment.data files crashes Mac OS 10.4

    Summary: Whenever I try to delete any of the thumb files from the iPhoto directory on my internal hard drive or my external backup drive, it crashes the computer (screen scrolls dark then says "Have to restart, hold button for several seconds" in mul

  • How do i use a tc when i already have a wireless router

    I have a wireless network set up in my house.  I want to add a time capsule for data storage and backup.  Do I have to plug the time capsule into the internet modem?  I already have all ports full.

  • Quality Inspection for the 1st time Receive of Batch

    Hi all. My requirement is just to do the quality inspection when the Batch(MCHA-CHARG) is received in the first time in MIGO. No quality inspection is required for next & consequtive goods receive for the same batch. for the 1st time receive, the sto

  • MAIL FREEZES

    I just upgraded to Leopard and the first problem I encountered was that mail won't exit and none of my email addresses work. I have several work related accounts and none of them seemed to work. I deleted the accounts so that I could rebuild them man

  • Я зарегистрировалась и загрузила на мак Adobe Premiere Pro CS5.5 - а как запустить?

    Зарегистрировалась и скачала для мака Adobe Premiere Pro CS5.5 -  более новые версии мой аппарат не потянет. А что дальше делать, чтоб работать? Куда давить, чтобы поехало? Ничего не понимаю! И русского ничего найти не могу!!! Денег с меня не попроси